THERMAL BARRIERTHERMAL BARRIER
PROJECT:
TITLE:
DRAWN BY: SOPREMA TECHNICAL SUPPORT, GGALLOWAY
NO.: DATE:REVISION:
DATE: 7.8.2015
SCALE: NTS
DRAWING NUMBER:
US.RSBS.03.04PARAPET WALL WITH METAL COPING
USAGE OF THIS DETAIL IS GOVERNED BY THE TERMS OF SERVICE FOR SOPREMA DETAILS.PLEASE CONSULT THESE TERMS OF SERVICE PRIOR TO UTILIZING THIS DRAWING.
US CORPORATE ADDRESS310 QUADRAL DRIVE
WADSWORTH, OHIO 44281www.soprema.usTel:330.334.0066
W I L L I A M G R A N T G A L L O W A Y
DRAWING MUST BE VIEWED IN ADOBE READER TO ENABLE CUSTOM LAYERING
NOTES:1. SOPREMA DETAIL DRAWINGS: REFER TO SOPREMA AND OTHER RELATED PUBLISHED DOCUMENTATION, PRODUCT DATA SHEETS (PDS) AND SAFETY DATA SHEETS (SDS) FOR ADDITIONAL
INFORMATION. ALL DETAIL DRAWINGS AND RELATED INSTALLATION GUIDELINES ARE PROVIDED BY SOPREMA FOR THE SOLE PURPOSE OF ISSUING A SOPREMA WARRANTY. ACCORDINGLY, THEDETAIL DRAWINGS ARE NOT OFFERED, AND SHOULD NOT BE CONSIDERED, AS A SUBSTITUTE FOR PROFESSIONAL DESIGN SERVICES.
2. HOT WORK: THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING APPROPRIATE CONDITIONS TO UTILIZE HEAT-WELDING EQUIPMENT. REFER TO THE NRCA CERTA RECOMMENDATIONS, LOCALCODES AND BUILDING OWNER'S REQUIREMENTS FOR HOT WORK OPERATIONS.
3. PRIMER: WHERE NOT SHOWN OR INDICATED ON DETAIL DRAWINGS, REFER TO MATERIAL PRODUCT DATA SHEETS FOR PRIMER APPLICATION REQUIREMENTS4. FLASHING PLIES MUST EXTEND VERTICALLY A MINIMUM OF 8" FROM ROOF SURFACE. FLASHING PLIES EXTENDING VERTICALLY MORE THAN 24" FROM ROOF SURFACE MUST BE ADHERED AND
MECHANICALLY FASTENED ALONG THE TOP LEADING EDGE. REFER TO PUBLISHED DOCUMENTATION.5. FOR 90° TRANSITIONS, FLASHING PLIES MUST MEET THE FOLLOWING REQUIREMENTS: HEAT WELD POLYESTER REINFORCED FLASHING BASE PLIES. HEAT WELD POLYESTER REINFORCED
GRANULE FLASHING CAP SHEET, OR HEAT WELD FOIL/FILM CLAD FLASHING CAP SHEET.
EXTEND FLASHING BASE PLY AMINIMUM OF 3" BEYOND BASE OF CANT
CANT
WEATHERPROOF MEMBRANE
ROOF EDGE SYSTEM
EXTEND FLASHING CAP SHEET AMINIMUM OF 1" BEYOND FLASHING BASE PLY
EXTEND FLASHING BASE PLY AMINIMUM OF 3" BEYOND BASE OF WALL
EXTEND FLASHING CAP SHEET AMINIMUM OF 1" BEYOND FLASHING BASE PLY
REMOVE/EMBED SURFACING AS REQUIREDREMOVE/EMBED SURFACING AS REQUIRED
FLASHING CAP SHEETFLASHING CAP SHEET
POLYESTER REINFOREDFLASHING BASE PLYPOLYESTER REINFOREDFLASHING BASE PLY
CAP SHEETCAP SHEET
BASE PLYBASE PLY
COVERBOARD
BASE SHEET/ANCHOR SHEET
VAPOR RETARDER/AIR BARRIERDECKDECKDECKDECKDECKDECKDECKDECK
FASTEN AT 8" O.C.ALONG TOP LEADING EDGE
FASTEN AT 8" O.C.ALONG TOP LEADING EDGE
2 PLY SBS MEMBRANE, INSULATED
EXTEND FLASHING BASE PLY AMINIMUM OF 3" BEYOND FASTENER PLATE
EXTEND FLASHING CAP SHEET AMINIMUM OF 1" BEYOND FLASHING BASE PLY
INSTALL FASTENER PLATE A MINIMUMOF 1" FROM WALL AND SPACED A
MAXIMUM OF 12" APART ALONG WALL
EXTEND FLASHING BASE PLY AMINIMUM OF 3" BEYOND FASTENER PLATE
EXTEND FLASHING CAP SHEET AMINIMUM OF 1" BEYOND FLASHING BASE PLY
INSTALL FASTENER PLATE A MINIMUMOF 1" FROM CANT AND SPACED A
MAXIMUM OF 12" APART ALONG WALL
BASE SHEET/ANCHOR SHEET
THERMAL BARRIER
INSULATION
INSULATION
INSULATION
INSULATIONEXTEND VAPOR RETARDER/AIR BARRIERA MINIMUM OF 3" BEYOND BASE OF WALL
VAPOR RETARDER/AIR BARRIER
FASTEN AT 8" O.C. INBOTH DIRECTIONS
FASTEN AT 8" O.C. INBOTH DIRECTIONS
BASE SHEET/ANCHOR SHEETBASE SHEET/ANCHOR SHEET