DMTFB wall-mount Clamp-on Ultrasonic Flow Meters Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters Features 1. Due to the non-invasive nature of the clamp-on technology, there is no pressure drop, no moving parts, no leakage, no risk of contamination and corrosion. 2. Measurement is independent of fluid conductivity with wider applications than magnetic meters. 3. Non-invasive, NEMA 4X (IP65) clamp-on transducer is easy to install and cost efficient. Since the transducers do not contact with the liquid, fouling and maintenance are eliminated. 4. Parallel operation of positive, negative and net flow totalizers with multiplier, while the output of totalizer pulse or flow rate frequency output are transmitted via open collector terminal. 5. Standard type and Explosion-Proof ATEX(ExdIIBT6; LCIE 09 ATEX 3008) type are available, with wide operating temperature range : - 40~250. 6. Wide range of pipe sizes from DN15 to 4500. 7. Clamp-on transducers require no pipe cutting or processing interrupted. 8. Wide bi-directional flow range of -40 to 40 ft/s (-12 to 12 m/s). 9. Up to 8GB SD card data logger can memory flow rate, total flow, velocity and time. Time interval can be freely setup by user. Note: K mode transducers utilize the Round-Clamp method, and the transducers' transmitting and receiving sides are connected with the pipe surface thoroughly to acquire enough coupling area, better reliability, stability, etc.

description

articulo

Transcript of Dmtfb Wall

  • DMTFB wall-mount Clamp-on Ultrasonic Flow Meters

    Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters

    Features

    1. Due to the non-invasive nature of the clamp-on technology, there is no pressure drop, no moving parts, no leakage, no risk of

    contamination and corrosion.

    2. Measurement is independent of fluid conductivity with wider applications than magnetic meters.

    3. Non-invasive, NEMA 4X (IP65) clamp-on transducer is easy to install and cost efficient. Since the transducers do not contact with the

    liquid, fouling and maintenance are eliminated.

    4. Parallel operation of positive, negative and net flow totalizers with multiplier, while the output of totalizer pulse or flow rate frequency

    output are transmitted via open collector terminal.

    5. Standard type and Explosion-Proof ATEX(ExdIIBT6; LCIE 09 ATEX 3008) type are available, with wide operating temperature range : -

    40~250.

    6. Wide range of pipe sizes from DN15 to 4500.

    7. Clamp-on transducers require no pipe cutting or processing interrupted.

    8. Wide bi-directional flow range of -40 to 40 ft/s (-12 to 12 m/s).

    9. Up to 8GB SD card data logger can memory flow rate, total flow, velocity and time. Time interval can be freely setup by user.

    Note: K mode transducers utilize the Round-Clamp method, and the transducers' transmitting and receiving sides are connected with the pipe surface

    thoroughly to acquire enough coupling area, better reliability, stability, etc.