DISTRIBUTION SYSTEMS M12 - WILLTECwilltec.kr/P3_2_b_Distribution systems M12.pdf · Distribution...
Transcript of DISTRIBUTION SYSTEMS M12 - WILLTECwilltec.kr/P3_2_b_Distribution systems M12.pdf · Distribution...
Dist
ribut
ion
syst
ems M
12
DISTRIBUTION SYSTEMS M12|
3.13.1
MVP12 Metal
4-,8-way •withpre-wiredhomeruncable,
shieldedorunshielded
•withplugconnectorM23
•withLEDforPNPorNPNsignals
•withoutLEDforanalogsignalsand
voltagesupto125VAC/DC
MVP12 Metal UNIVERSAL
4-way •withpre-wiredhomeruncable
•withplugconnectorM23
•M12Pin1,2,3,and4forfreeconfiguration
For rough environments Pluggable or pre-wired homerun cable
Exact12
4-,8-way •withpre-wiredhomeruncable
•forPNPorNPNsignals
•withoutLEDforvoltagesupto125VAC/DC
Exact12 basic housing
4-,8-way •forPNPorNPNsignals
•withoutLEDforvoltagesupto125VAC/DC
Exact12/MVP12 connection cap
•field-wireablewithscreworspringclampterminals
•withpluggablehomeruncable
andscrewplug-interminals
For general applications Pluggable or pre-wired homerun cable
frompage3.13.3
frompage3.13.5
page3.13.10
For general applications Pluggable homerun cable
frompage3.13.8
page3.13.15
3_13_1_10_E.indd 2 01.04.2010 16:10:57 Uhr
Dist
ribut
ion
syst
ems M
12
DISTRIBUTION SYSTEMS M12|
3.13.2
Exact12 Set
4-,8-way •withpluggablecapandscrewplug-interminals
•withpluggablecapandspringclampterminals
MVP12
8-way •withpluggablebackplateconnection
–field-wireable
–withpre-wiredsinglewires
•potentialseparationasoption
Exact12/MVP12
4-,6-,8-way •with12-or19-poleplugconnectorM23
•with12-or19-poleplugconnectorM23,90°
Exact12/MVP12 UNIVERSAL
4-way •withpre-wiredhomeruncable
•withpluggablecapandscrewplug-interminals
•withpluggablecapandspringclampterminals
•M12Pin1,2,3,and4forfreeconfiguration
MSDS Safety Distribution System
8-way •withpluggablecapandscrewplug-interminals
•withandwithoutelectricalfeedback
EMERGENCY-STOP button •toconnecttoMSDSwithM12plugs
For safety wiring Pluggable homerun cable
For general applications Pluggable homerun cable
frompage3.13.11
frompage3.13.14
page3.13.17
3_13_1_10_E.indd 3 01.04.2010 16:11:06 Uhr
Dist
ribut
ion
syst
ems M
12
DISTRIBUTION SYSTEMS M12|
3.13.3
MVP12 Metal 4-way,8-way
Fordigitaloranalogsignals
For sensors and actuators
– homerun cable, PUR
– suitable for C-tracks, halogen free
– unshielded or shielded
Approvals:
Notes
1)Viapotentialseparationsockets1,3,5,7or2,4,6,8mayvary.
Technicaldatainchapter3.14.Accessoriesonpage3.13.18.
*
Contact layout
General:
Contact1: (+)
Contact2: (N/C)/(S2)
Contact3: (–)
Contact4: (N/O)/(S1)
Contact5: (PE)
LEDindicator: LEDgreen,power
LEDyellow,signal
Shielding: M12threadedsleeve
with LED without LEDforanalogsignals with LED
fordigitalPNP-signals24VDC ornominalvoltageupto125VAC/DC fordigitalNPNsignals24VDC
Distribution box 4-way unshielded Art.-No. Art.-No.
Homeruncable Cablelength
PUR(UL/CSA) 3.0 m 27471 27476
halogenfree,8x0.5/3x1mm2 5.0 m 27472 27477
10.0 m 27473 27478
cableno.448 15.0 m 27474 27479
Distribution box 8-way unshielded Art.-No. Art.-No. Art.-No.
Homeruncable Cablelength
PUR(UL/CSA) 3.0 m 27491 27496 27560
halogenfree,16x0.5/3x1mm2 5.0 m 27492 27497 27561
10.0 m 27493 27498 27562
cableno.452 15.0 m 27494 27499 27563
Potentialsepartionasoption, 3.0 m 27521
left/rightside1), 5.0 m 27522
PUR(UL/CSA)halogenfree, 10.0 m 27523
16x0.34/5x0.75mm2, 15.0 m 27524
cableno.403
Distribution box 4-way shielded Art.-No. Art.-No.
Homeruncable Cablelength
PUR(UL/CSA), 3.0 m 27481 27486
halogenfree, 5.0 m 27482 27487
8x0.34/3x0.75mm2, 10.0 m 27483 27488
cableno.373 15.0 m 27484 27489
Distribution box 8-way shielded Art.-No. Art.-No.
Homeruncable Cablelength
PUR(UL/CSA), 3.0 m 27511 27516
halogenfree, 5.0 m 27512 27517
16x0.34/3x0.75mm2, 10.0 m 27513 27518
cableno.401 15.0 m 27514 27519
45
3
12
M12 female
5-pole
for2signalsperport
3_13_1_10_E.indd 4 01.04.2010 16:11:09 Uhr
Dist
ribut
ion
syst
ems M
12
DISTRIBUTION SYSTEMS M12|
3.13.4
MVP12 Metal 4-way,8-way
Fordigitaloranalogsignals
For sensors and actuators
– with 19-pole plug connector M23
– unshielded or shielded
Approvals:
Contact layout
General:
Contact1: (+)
Contact2: (N/C)/(S2)
Contact3: (–)
Contact4: (N/O)/(S1)
Contact5: (PE)
LEDindicator: LEDgreen,power
LEDyellow,signal
Shielding: M12threadedsleeve
M23outerthread
Notes
SuitableM23mastercablesinchapter3.7.
Technicaldatainchapter3.14.Furtheraccessoriesseepage3.13.18.
*
with LED without LED
fordigitalPNP-signals24VDC foranalogsignalsornominalvoltageupto125VAC/DC
Ordering data Art.-No. Art.-No.
Distributionbox4-way 27530 27531
Distributionbox8-way 27535 27536
Accessories Art.-No.
V2A-baseplate f.4-waydistr.box forbackplatedEMC-protection,withfixingbolts 996065
Stainlesssteel f.8-waydistr.box forbackplatedEMC-protection,withfixingbolts 996066
Protectiveconductorconnectionset cablefork1.5…2.5mm2,screw,washerandlockwasher 996064
Groundstrap length=100mm,toimproveconnectiontoground 4000-71001-0410003
Mountingsetforgroundstrap withmountingscrews,washers,nutsandlabels 4000-71003-0101403
M12 female
5-pole
M23 male
19-pole
43
12
59
8
1
210
12
7
3
65
4
P0
19
13
14
1516
17
18
11
for2signalsperport
3_13_1_10_E.indd 5 01.04.2010 16:11:14 Uhr
3.13.5
Exact12 Exact12 4-way 8-way
1 2 3
Cable type Jacket color Jacket color
Cable length
Article no.
Form Cable type Cable length
3.0m PNP 0300
5.0m PNP / NPN 0500
10.0m PNP / NPN 1000
15.0m PNP 1500
Contact layout 4-pole 4-pole
Contact layout
Form P N P / N P N 8 4 4 1 0 / 8 4 4 1 1 8 8 4 1 0 / 8 8 4 1 1
The composition of your article
number is explained on page 3.1.2 8 0 0 0
gray gray
PUR/PVC 333 362
Wirediameter 4x0.34/3x0.75mm2 8x0.34/3x0.75mm2
General:
Contact1: (+)
Contact3: (–)
Contact4: (N/O)/(S1)
Contact5: (PE)
LEDindicator: LEDgreen,power
LEDyellow,signal(S1)
– –
Dist
ribut
ion
syst
ems M
12
DISTRIBUTION SYSTEMS M12|
*
45
3
12
M12 female
4-pole
For sensors and actuators
– for PNP or NPN signals
– homerun cable, PUR/PVC
Approvals:
1
3
2
for1signalperport
Notes
Technicaldatainchapter3.14.Accessoriesonpage3.13.18.
Othercablelengthsonrequest..
3_13_1_10_E.indd 6 01.04.2010 16:11:18 Uhr
Dist
ribut
ion
syst
ems M
12
3.13.6
DISTRIBUTION SYSTEMS M12|
Exact12 Exact12 4-way 8-way
1 2 3
Cable type Jacket color Jacket color
Cable length
Article no.
Form Cable type Cable length
3.0m PNP 0300
5.0m PNP / NPN 0500
10.0m PNP / NPN 1000
15.0m PNP 1500
Contact layout 5-pole 5-pole
Contact layout
Form P N P / N P N 8 4 5 1 0 / 8 4 5 1 1 8 8 5 1 0 / 8 8 5 1 1
The composition of your article
number is explained on page 3.1.2 8 0 0 0
gray gray
PUR/PVC 363 398
PUR(UL/CSA), halogenfree 448 452
WirediameterPUR/PVC 8x0.34/3x0.75mm2 16x0.34/3x0.75mm2
WirediameterPUR 8x0.5/3x1.0mm2 16x0.5/3x1.0mm2
General:
Contact1: (+)
Contact2: (N/C)/(S2)
Contact3: (–)
Contact4: (N/O)/(S1)
Contact5: (PE)
LEDindicator: LEDgreen,power
LEDyellow,signal(S1)
LEDwhite,signal(S2)
– –
*
45
3
12
M12 female
5-pole
For sensors and actuators
– for PNP or NPN signals
– homerun cable, PUR/PVC
Approvals:
1
3
2
for2signalsperport
Notes
Technicaldatainchapter3.14.Accessoriesonpage3.13.18.
Othercablelengthsonrequest..
3_13_1_10_E.indd 7 01.04.2010 16:11:24 Uhr
Dist
ribut
ion
syst
ems M
12
DISTRIBUTION SYSTEMS M12|
3.13.7
Exact12 Exact12 4-way 8-way
1 2 3
Cable type Jacket color Jacket color
Cable length
Article no.
Form Cable type Cable length
5.0m 0500
10.0m 1000
Contact layout 4-pole 4-pole 5-pole 5-pole
Contact layout
Form w i t h o u t L E D 8 4 4 1 2 8 8 4 1 2 8 4 5 1 2 8 8 5 1 2
The composition of your article
number is explained on page 3.1.2 8 0 0 0
gray gray
PUR/PVC 363 398
PUR(UL/CSA),halogenfree 452
WirediameterPUR/PVC 8x0.34/3x0.75mm2 16x0.34/3x0.75mm2
WirediameterPUR 16x0.50/3x1.0mm2
General:
Contact1: (+)
Contact2: (N/C)/(S2)
Contact3: (–)
Contact4: (N/O)/(S1)
Contact5: (PE)
– –
*
45
3
12
M12 female
5-pole
For sensors and actuators
– without LED, up to 125 V AC/DC
– homerun cable, PUR or PUR/PVC
Approvals:
1
3
2
45
3
12
M12 female
4-pole
for1signalperport for2signalsperport
Notes
Technicaldatainchapter3.14.Accessoriesonpage3.13.18.Othercablelengthonrequest.
1)ULonlywhenininstalledinclass2powersupply.
3_13_1_10_E.indd 8 01.04.2010 16:11:28 Uhr
Dist
ribut
ion
syst
ems M
12
Ordering data Art.-No. Art.-No.
FormPNP 8000-84400-000 0000 8000-88400-000 0000
FormNPN 8000-84401-000 0000 8000-88401-000 0000
WithoutLED1) 8000-84402-000 0000 8000-88402-000 0000
DISTRIBUTION SYSTEMS M12|
Exact12 Basic housing Exact12 Basic housing 4-way 8-way
For sensors and actuators
– basic housings
– for 24 V (PNP or NPN signals)
– without LED, up to 125 V AC/DC
Approvals:*
3 5 4
2 1
M12 female4-pole
-1 +1 1 3 PE 4 2 +2 -23 5 4
2 1
M12 female4-pole
-1 +1 1 3 PE 4 2 +2 -2
5 7 15 8 6
Notes
Technicaldatainchapter3.14.Accessoriesonpage3.13.18.Suitableconnectioncapsonpage3.13.10.
1)ULonlywhenininstalledinclass2powersupply.3.13.8
Contact layout
General:
Contact1: (+)
Contact3: (–)
Contact4: (N/O)/(S1)
Contact5: (PE)
OnlywihPNPandNPNsignals for1signalperport for1signalperport
LEDindicator: LEDgreen,power
LEDyellow,signal
3_13_1_10_E.indd 9 01.04.2010 16:11:32 Uhr
Dist
ribut
ion
syst
ems M
12
Exact12 Basic housing Exact12 Basic housing 4-way 8-way
For sensors and actuators
– basic housings
– for 24 V (PNP or NPN signals)
– without LED, up to 125 V AC/DC
Approvals:
Contact layout
General:
Contact1: (+)
Contact2: (N/C)/(S2)
Contact3: (–)
Contact4: (N/O)/(S1)
Contact5: (PE)
OnlywihPNPandNPNsignals for2signalsperport for2signalsperport
LEDindicator: LEDgreen,power
LEDyellow,signal(S1)
LEDwhite,signal(S2)
*
3 5 4
2 1
M12 female5-pole
9 11 13 16 14 12 10
-1 +1 1 3 PE 4 2 +2 -2
3 5 4
2 1
M12 female5-pole
9 11 13 16 14 12 10
-1 +1 1 3 PE 4 2 +2 -2
5 7 15 8 6
Ordering data Art.-No. Art.-No.
FormPNP 8000-84500-000 0000 8000-88500-000 0000
FormNPN 8000-84501-000 0000 8000-88501-000 0000
WithoutLED1) 8000-84502-000 0000 8000-88502-000 0000
3.13.9
DISTRIBUTION SYSTEMS M12|
Notes
Technicaldatainchapter3.14.Accessoriesonpage3.13.18.Suitableconnectioncapsonpage3.13.10.
1)ULonlywhenininstalledinclass2powersupply.
3_13_1_10_E.indd 10 01.04.2010 16:11:36 Uhr
Dist
ribut
ion
syst
ems M
12
DISTRIBUTION SYSTEMS M12|
Exact12 Cap Forcablediameter8.5…14.0mm
Contact layout
General:
Contact1: (+)
Contact2: (N/C)/(S2)
Contact3: (–)
Contact4: (N/O)/(S1)
Contact5: (PE)
for1signalperport for2signalsperport for2signalsperport for2signalsperport
potentialsepartionasoption
With cable for 4-way distrib. box Art.-No. Art.-No. Art.-No. Art.-No.
Cabletype PUR/PVC PUR/PVC PUR/PVC PUR(UL/CSA) halogenfree
3.0 m 8000-84459-333 0300 8000-84559-363 0300 8000-84659-374 0300 8000-84559-448 0300
5.0 m 8000-84459-333 0500 8000-84559-363 0500 8000-84659-374 0500 8000-84559-448 0500
10.0 m 8000-84459-333 1000 8000-84559-363 1000 8000-84659-374 1000 8000-84559-448 1000
15.0 m 8000-84459-333 1500 8000-84559-363 1500 8000-84659-374 1500 8000-84559-448 1500
20.0 m 8000-84459-3332000 8000-84559-3632000 8000-84659-3742000 8000-84559-4482000
25.0 m 8000-84459-3332500 8000-84559-3632500 8000-84659-3742500 8000-84559-4482500
30.0 m 8000-84459-3333000 8000-84559-3633000 8000-84659-3743000 8000-84559-4483000
Wirediameter 4x0.34/3x0.75mm2 8x0.34/3x0.75mm2 8x0.34/5x0.75mm2 8x0.5/3x1.0mm2
Cableno. 333 363 374 448
With cable for 8-way distrib. box Art.-No. Art.-No. Art.-No. Art.-No.
Cabletype PUR/PVC PUR/PVC PUR/PVC PUR(UL/CSA) halogenfree
3.0 m 8000-88459-362 0300 8000-88559-398 0300 8000-88659-404 0300 8000-88559-452 0300
5.0 m 8000-88459-362 0500 8000-88559-398 0500 8000-88659-404 0500 8000-88559-452 0500
10.0 m 8000-88459-362 1000 8000-88559-398 1000 8000-88659-404 1000 8000-88559-452 1000
15.0 m 8000-88459-362 1500 8000-88559-398 1500 8000-88659-404 1500 8000-88559-452 1500
20.0 m 8000-88459-3622000 8000-88559-3982000 8000-88659-4042000 8000-88559-4522000
25.0 m 8000-88459-3622500 8000-88559-3982500 8000-88659-4042500 8000-88559-4522500
30.0 m 8000-88459-3623000 8000-88559-3983000 8000-88659-4043000 8000-88559-4523000
Wirediameter 8x0.34/3x0.75mm2 16x0.34/3x0.75mm2 16x0.34/5x0.75mm2 16x0.5/3x1.0mm2
Cableno. 362 398 404 452
Without cable Art.-No.
Withscrewplug-interminals 8000-88559-000 0000
Withspringclampterminals 8000-88549-000 0000
Technical data
Homeruncable forcablediameter8.5…14.0mm
*
45
3
12
M12 female
4-pole
M12 female
5-pole
45
3
12
M12 female
5-pole
45
3
12
M12 female
5-pole
45
3
12
3.13.10
For sensors and actuators
– field-wireable connection cap
– pre-wired with screw plug-in terminals
Approvals:
Notes
Furthertechnicaldatainchapter3.14.Accessoriesonpage3.13.17
3_13_1_10_E.indd 11 01.04.2010 16:11:42 Uhr
Dist
ribut
ion
syst
ems M
12
DISTRIBUTION SYSTEMS M12|
Exact12 Basic Module and Cap Exact12 Basic Module and Cap 4-way 8-way
For sensors and actuators
– field-wiring set
– screw plug-in or spring clamp plug-in terminals
Approvals:
Contact layout
General:
Contact1: (+)
Contact3: (–)
Contact4: (N/O)/(S1)
Contact5: (PE)
OnlywihPNPandNPNsignals for1signalperport for1signalperport
LEDindicator: LEDgreen,power
LEDyellow,signal
*
3 5 4
2 1
M12 female4-pole
-1 +1 1 3 PE 4 2 +2 -23 5 4
2 1
M12 female4-pole
-1 +1 1 3 PE 4 2 +2 -2
5 7 15 8 6
Notes
Furthertechnicaldatainchapter3.14.Accessoriesonpage3.13.18.
1)ULonlywhenininstalledinclass2powersupply.3.13.11
Screw plug-in terminals Art.-No. Art.-No.
FormPNP 8000-84450-000 0000 8000-88450-000 0000
FormNPN 8000-84451-000 0000 8000-88451-000 0000
WithoutLED1) 8000-84452-000 0000 8000-88452-000 0000
Spring clamp plug-in terminals Art.-No. Art.-No.
FormPNP 8000-84440-000 0000 8000-88440-000 0000
Technical data
Homeruncable forcablediameter8.5…14.0mm
3_13_1_10_E.indd 12 01.04.2010 16:11:46 Uhr
Dist
ribut
ion
syst
ems M
12
DISTRIBUTION SYSTEMS M12|
3.13.12
Exact12 Basic Module and Cap Exact12 Basic Module and Cap 4-way 8-way
For sensors and actuators
– field-wiring set
– screw plug-in or spring clamp plug-in terminals
Approvals:
Contact layout
General:
Contact1: (+)
Contact2: (N/C)/(S2)
Contact3: (–)
Contact4: (N/O)/(S1)
Contact5: (PE)
OnlywihPNPandNPNsignals for2signalsperport for2signalsperport
LEDindicator: LEDgreen,power
LEDyellow,signal(S1)
LEDwhite,signal(S2)
*
3 5 4
2 1
M12 female5-pole
9 11 13 16 14 12 10
-1 +1 1 3 PE 4 2 +2 -2
3 5 4
2 1
M12 female5-pole
9 11 13 16 14 12 10
-1 +1 1 3 PE 4 2 +2 -2
5 7 15 8 6
Notes
Furthertechnicaldatainchapter3.14.Accessoriesonpage3.12.18.
1)ULonlywhenininstalledinclass2powersupply.
Screw plug-in terminals Art.-No. Art.-No.
FormPNP 8000-84550-000 0000 8000-88550-000 0000
FormNPN 8000-84551-000 0000 8000-88551-000 0000
WithoutLED1) 8000-84552-000 0000 8000-88552-000 0000
Spring clamp plug-in terminals Art.-No. Art.-No.
FormPNP 8000-84540-000 0000 8000-88540-000 0000
Technical data
Homeruncable forcablediameter8.5…14.0mm
3_13_1_10_E.indd 13 01.04.2010 16:11:50 Uhr
Dist
ribut
ion
syst
ems M
12
DISTRIBUTION SYSTEMS M12|
3.13.13
MVP12 MVP12 Set 8-way 8-way
Fordirectmountingoncontrolcabinets Fordirectmountingoncontrolcabinets
For sensors and actuators
– with back plate pluggable terminals
– with foamed up gasket
– single components and sets
Approvals:
Contact layout
General:
Contact1: (+)
Contact2: (N/C)/(S2)
Contact3: (–)
Contact4: (N/O)/(S1)
Contact5: (PE)
LEDindicator: LEDgreen,power
LEDyellow,signal
Notes
Controlcabinetcut-out,Ø42mmroundor29mmx43mmsquare(HxW)
Technicaldatainchapter3.14.Accessoriesonpage3.13.17
Single components Art.-No. Art.-No.
Basichousing 27122
Screwplug-interminals 27123
Springclampplug-interminals 27133
Pre-wiredscrewplug-interminals 1.0mPVCwires16x0.34+5x0.75mm2,cableno.404 4627151
Pre-wiredscrewplug-interminals 3.0mPVCwires16x0.34+5x0.75mm2,cableno.404 4627153
Sets Art.-No.
Basicmodulewithscrewplug-interminals 27158
Setwithpre-wiredscrewterminals 1.0mPVCwires16x0.34+5x0.75mm2,cableno.404 27151
Setwithpre-wiredscrewterminals 3.0mPVCwires16x0.34+5x0.75mm2,cableno.404 27153
for2signalsperport/potentialseparationasoption
3 5 4
1210 12 14 16 13 11 9
-2 +2 2 4 PE 3 1 +1 -1
6 8 15 7 5
M12 female5-pole
Screw plug-in terminals max. 1.5 mm2/A WG 16
bridge 2 bridge 1
3 5 4
1210 12 14 16 13 11 9
-2 +2 2 4 PE 3 1 +1 -1
6 8 15 7 5
M12 female5-pole
Screw plug-in terminals max. 1.5 mm2/A WG 16
bridge 2 bridge 1
for2signalsperport/potentialseparationasoption
3_13_1_10_E.indd 14 01.04.2010 16:11:54 Uhr
Dist
ribut
ion
syst
ems M
12
DISTRIBUTION SYSTEMS M12|
3.13.14
Exact12 MVP12 4-way,8-way 4-way,6-way,8-way
WithplugconnectorM23 WithplugconnectorM23,90°
For sensors and actuators
– with 12- or 19-pole plug connector M23
Approvals:
Contact layout
General:
Contact1: (+)
Contact2: (N/C)/(S2)
Contact3: (–)
Contact4: (N/O)/(S1)
Contact5: (PE)
LEDindicator: LEDgreen,power for1signalperport for2signalsperport for2signalsperport for2signalsperport
LEDyellow,signal(S1)
LEDwhite,signal(S2)
Notes
Technicaldatainchapter3.14.Furtheraccessoriesonpage3.13.18.
SuitableM23homeruncablesseechapter3.7.
*
Ordering data Art.-No. Art.-No. Art.-No. Art.-No.
Distributionbox4-way 8000-84530-000 0000 8000-84520-000 0000 27287
Distributionbox6-way 27786
Distributionbox8-way 8000-88430-000 0000 8000-88520-000 0000 27785
Accessories
ConnectioncableM23 12-/19-pole inchapter3.7
M12 female
4-pole
M23 male
12-pole
43
12
59
21012
18
7
P036
4511
M12 female
4-pole
M23 male
12-pole
43
12
59
21012
18
7
P036
4511
M12 female
5-pole
M23 male
19-pole
43
12
59
8
1
210
12
7
3
65
4
P0
19
13
14
1516
17
18
11
M12 female
5-pole
M23 male
19-pole
43
12
59
8
1
210
12
7
3
65
4
P0
19
13
14
1516
17
18
11
3_13_1_10_E.indd 15 01.04.2010 16:11:58 Uhr
Dist
ribut
ion
syst
ems M
12
3.13.15
DISTRIBUTION SYSTEMS M12|
*
MVP12 Metal UNIVERSAL MVP12 Metal UNIVERSAL 4-way 4-way
Withpre-wiredhomeruncable(PUR) WithplugconnectorM23
For rough environments
– homerun cable, PUR
– with 19-pole plug connector M23
Approvals:
Contact layout
General:
Contact1: (S1)
Contact2: (S2)
Contact3: (S3)
Contact4: (S4)
Contact5: (PE)
WithoutLEDindicator,
nominalvoltagemax.42VAC/DC
Notes
Technicaldatainchapter3.14.Accessoriesonpage3.13.18.
With cable Art.-No.
Homeruncable Cablelength
PUR(UL/CSA), 3.0m 27461
halogenfree, 5.0m 27462
16x0.5/1x1mm2, 10.0m 27463
shielded, 15.0m 27464
cableno.401
With plug connector Art.-No.
PlugconnectorM23 27533
for4signalspersocket
M12 female
5-pole
M23 male
19-pole
43
12
59
8
1
210
12
7
3
65
4
P0
19
13
14
1516
17
18
11
free arrangeablePE bridged
for4signalspersocket
45
3
12
M12 female
5-pole
free arrangeablePE bridged
3_13_1_10_E.indd 16 01.04.2010 16:12:02 Uhr
Dist
ribut
ion
syst
ems M
12
3.13.16
DISTRIBUTION SYSTEMS M12|
*
MVP12 UNIVERSAL Exact12 UNIVERSAL 4-way 4-way
Withpluggablecap Withpre-wiredhomeruncablePUR/PVC
For general applications
– with pluggable cap
– homerun cable, PUR PUR/PVC
Approvals:
Contact layout
General:
Contact1: (S1)
Contact2: (S2)
Contact3: (S3)
Contact4: (S4)
Contact5: (S5)/(PE)
WithoutLEDindicator,
nominalvoltagemax.42VAC/DC
Notes
Furthertechnicaldatainchapter3.14.Accessoriesonpage3.13.18.
Pluggableconnectioncapwithcableonrequest.
Single components Art.-No.
Basichousing 276624
Capwithscrewplug-interminals 276626
Pre-wiredcap(bridgedPE) 1.0mPUR/PVC18x0.75mm2,cableno.533 276760
Pre-wiredcap(bridgedPE) 5.0mPUR/PVC18x0.75mm2,cableno.533 276829
Sets Art.-No.
Basicmodulewithscrewplug-interminals 276625
Basicmodulewithspringclampplug-interminals 277303
Exact12 UNIVERSAL Art.-No.
Homeruncable Cablelength
PUR/PVC, 3.0m 8000-84712-3980300
16x0.34/ 5.0m 8000-84712-3980500
1x0.75mm2, 10.0m 8000-84712-3981000
cableno.398 15.0m 8000-84712-3981500
Technical data
Homeruncable forcablediameter8.5…14.0mm –
3 5 4
2 1
M12 female5-pole
11 10 9 14 13 7 5
4 3 2 1 12 15 16 6 8
17 19 21 20 18
bridge 1 bridge 2
bridge 3 bridge 4free arrangeable
Contacts1:1onterminals/max.5signalspersocket
45
3
12
M12 female
5-pole
free arrangeablePE bridged
for4signalspersocket
3_13_1_10_E.indd 17 01.04.2010 16:12:07 Uhr
Dist
ribut
ion
syst
ems M
12
3.13.17
Notes
Technicaldatainchapter3.14.Furtheraccessoriesfoundonpage3.13.18.
DISTRIBUTION SYSTEMS M12|
MSDS 8 MSDS 8R EMERGENCY-STOP button Withoutelectricalfeedback Withelectricalfeedback WithM12plug
WithoutLEDs WithLEDs
Safety distribution box M12
– with pluggable cap
EMERGENCY-STOP button
– with M12 connector
Contact layout
Ports: MSDS MSDS EMERGENCY-
STOP
yellow black black
Contact1: 11 13 11
Contact2: 12 14 12
Contact3: 21 21
Contact4: 22 22
LEDindicator: LEDgreen,power
LEDyellow,EMERGENCY-STOP
Ordering data Art.-No. Art.-No.
8-way 8-way
27057 27292
EMERGENCY-STOP button Art.-No.
WithM12connection 55550
Accessories Art.-No.
Codingplug 332779
Protectioncap 58627
T-coupler 7000-41165-000 0000
Technical data
Homeruncable forcablediameter8.5…14.0mm –
3 5 4 yellow
2 1
3 5 4 black
2 1
M12 female
9 11 13 16 14 12 10
-1 +1 1 3 PE 4 2 +2 -2
5 7 15 8 6
Screw plug-in terminals max. 1.5 mm2/A WG 16
4 5
1 2
3 black
M12 male
3_13_1_10_E.indd 18 01.04.2010 16:12:11 Uhr
Notes
Technicaldatainchapter3.14.
AccESSORIES|
Plug accessories Art.-No.
M12torquewrench 7000-99102-000 0000
(torquecalibrated0.6Nm)
M12blindplug plastic 10pieces 58627
M12blindplug metal 1piece 996049
LabelplatesMVP12Metal 2plates=10pieces,(MurrplastikKES20x8) 996067
LabelplatesMVP12/Exact12 2plates=12pieces,(MurrplastikABB17x9typeM) 996050
AdapterM12/M8forconnectionof3-poleM8connectortoM12distributionbox 7000-42201-000 0000
AdapterM12/M8forconnectionof4-poleM8connectortoM12distributionbox 7000-42211-000 0000
Homerun cable accessories Art.-No.
Codingelementsforconnectioncap for6codings 996054
M23blindplugmetal forunusedM23ports 55352
Capfor4-,6-and8-waydistributionboxM12,withscrewplug-interminalswithoutcable 4127785
Capfor4-,6-and8-waydistributionboxM12,withspringclampplug-interminalswithoutcable 4127795
Forcablediameter8.5…14.0mm
Cable(50m),5-polePUR/PVC
For4-waydistributionbox,cableno.363 8x0.34/3x0.75mm2 8000-00000-363 5000
For6-waydistributionbox,cableno.388 12x0.34/3x0.75mm2 8000-00000-388 5000
For8-waydistributionbox,cableno.398 16x0.34/3x0.75mm2 8000-00000-398 5000
Cable(50m),5-polePUR(UL/CSA),halogenfree
For4-waydistributionbox,cableno.448 8x0.5/3x1mm2 8000-00000-448 5000
For8-waydistributionbox,cableno.452 16x0.5/3x1mm2 8000-00000-452 5000
For8-waydistributionbox,cableno.403 16x0.34/5x0.75mm2 8000-00000-403 5000
(potentialsepartionasoption)
Cable(50m),PUR/PVC
For4-wayUNIVERSALdistributionbox, 18x0.75mm2 8000-00000-533 5000
Cableno.533
Mounting accessories Art.-No.
SnapfootforDIN-rail(EN60715) forconvenientDIN-railmounting 27905
Withfixingbolts,plastic
Dist
ribut
ion
syst
ems M
12
3.13.18