Distributed Control System DCS · 2020-02-05 · DISTRIBUTED CONTROL SYSTEM / DCS STRONG MODULAR...

16
Innovation in Automation www.mikrodev.com Distributed Control System DCS SCADA IOT GATEWAY HMI PLC REMOTE I/O RTU

Transcript of Distributed Control System DCS · 2020-02-05 · DISTRIBUTED CONTROL SYSTEM / DCS STRONG MODULAR...

Innovation in Automationwww.mikrodev.com

Distributed Control System

DCS

SCADA

IOTGATEWAY

HMI

PLCREMOTEI/ORTU

MODBUS TCP / RTU

IEC60870-5-103

IEC61850

Power Protection Relay Quality Analyzer

Flowmeter Soft Starter Inverter

DM500

MP110

MODBUSTCP

RTU MP211

Inverter

Flowmeter Soft Starter

Inverter

Flowmeter Soft Starter

ViewPLUS SCADA

1.Workstation n. Workstation

IEC60870-5-104 IEC60870-5-101 IEC61850

MODBUS DNP3MQTT DLMS/COSEM

HMI HMI

IEC60870-5-104

DNP3

MODBUS TCP

IEC61850

MODBUS TCP

MODBUS TCP / RTU MODBUSTCP / RTU

DISTRIBUTED CONTROL SYSTEM / DCS

Innovation in Automation

PHYSICAL SIGNALS

DM500(Redundant)

RIO

MODBUS TCP MODBUS TCP

GATEWAY

Electric Meter Water Meter Natural Gas Meter

Flowmeter Soft Starter InverterCalorimeter

Analog Signals Digital Signals

Resistive Signals

Hot Stand-by Redundant

HMI HMI HMI

IEC62056-21

DLMS/COSEM

MODBUS RTU

M-BUS

Innovation in Automation

ARM Cortex-A8 Processors (1 GHz CPU)

2 GB DDR3L SO-DIMM memory

512 MB DDR3 SD RAM

512 MB Nand Flash

2 x Ethernet communication interface

-25 C with +75 C working temperature

2 x RS485 and 2 x RS232 communication ports

2.5 kV/dk. protection against uctuating voltage

16 different connections available on each Ethernet port

Hot stand-by redundant operation

Possibility to change under energy for expansion modules.

Programming editor in EC 61131-3 standards

50000 sinyale kadar zaman etiketli kayıt kapasitesi

(1 ms acc.)

4-Slot Dual DM500 Chassis

2 slots for Redundant Power Supply

2 slots for redundant CPU

4 slots for I / O module

12-Slot DM500 Chassis

2 slots for Redundant Power Supply

2 slots for redundant CPU

8 slots for I / O module

18-Slot DM500 Chassis

2 slots for Redundant Power Supply

2 slots for redundant CPU

14 slots for I / O module

RACK PANEL ALTERNATIVES

COMMUNICATION STANDARDS

MODBUS TCP, RTU, TUNNEL, ASCII

DNP3 LAN/WAN

IEC60870-5-101/103

IEC60870-5-7

IEC60870-5-104

IEC61850 MMS

IEC62056-21

IEC62351-3,4,5,6,8

DM500 RACK INSTALLATION CPU FEATURES

MQTT

SNMP

DNP3 IEC60870-5MODBUS MQTT IEC61850 MMS IEC62056-21 IEC62351

GENERAL

ARM Cortex-A7 Processors (528 MHz)

512 GB DDR3 SD RAM

256 MB Nand Flash

2 x Ethernet communication interface

4 x Serial Ports (RS232 or RS485)

2.5 kV/dk. protection against alternating voltage

16 x Digital Inputs (Optical Isolation)

8 x Analog Inputs (16 Bit)

8 x Digital Output (Optical Isolation, 2A)

SD Card Feature

Up to 50000 signals with 1 ms precision time stamp

data recording

512 points with XIO211 Series expansion modules

to be able to expand

Programming editor in accordance with IEC 61131-3

standards

-25 C with +75 C operating temperature

GENERAL

DM400 DIN-RAIL MOUNT CPU FEATURES

Innovation in Automation

DISTRIBUTED CONTROL SYSTEM / DCS

DISTRIBUTED CONTROL SYSTEM / DCS

STRONG MODULAR DESIGN

XIO500.AI8 XIO500.AO8 XIO500.DI16Analog Input Module Analog Output Module Digital Input Module

XIO500.DO16Digital Output Module

ANALOG INPUT MODULE

Discrete as user congurable 8 DC analog inputs with

isolation

Precise measurement with 16-bit ADC infrastructure

+/-25 mA,0-25 mA,+/-20 mA,0-24 mA,0-20 mA,4-20 mA

0-10V, +/- 10V congurable measuring ranges

ANALOG OUTPUT MODULE

Discrete as user congurable 8 DC analog outputs

with isolation

Precision output with 16-bit ADC infrastructure

+/-25 mA,0-25 mA,+/-20 mA,0-24 mA,0-20 mA,4-20 mA

0-10V, +/- 10V congurable measuring ranges

DIGITAL INPUT MODULE

DIGITAL OUTPUT MODULE

16 single or 8 double, optically isolated digital outputs

2A @ 24VDC switching voltage

PS500Power Supply Module

POWER SUPPLY MODULE

Input: 24, 48, 60 VDC ve 24, 48, 100…120, 200…240 VAC

Short-circuit protected power supply input

16 single or 8 double, optically isolated digital inputs

Switching voltage in the range of 0-130 VDC

Protection capacity against uctuating voltage of 1.5 kV / min

Monitoring and tracking leds

Signal level indicator

Protection capacity against uctuating voltage of 1.5 kV / min

Monitoring and tracking leds

Signal level indicator

Protection capacity against uctuating voltage of 1.5 kV / min

Monitoring and tracking leds

Protection capacity against uctuating voltage of 1.5 kV / min

Monitoring and tracking leds

Output: 9-48 VDC

Status leds Failure / Operation

Innovation in Automation

It works on all platforms such as Windows, Linux and MacOS

Database supports such as Oracle and PostgreSQL

Highly secure SSL-based communication with operator clients

Unlimited operator client support (limited to server hardware)

Wide industrial and distributed network communication protocol

driver support (MODBUS, IEC104, DNP3 etc.)

SCADA Server

PNG, JPG etc. Creating components from popular formats

Designing animation

Creating project-specic object libraries

Component Management

It works in Windows, Linux, MacOS, Android and iOS

environments

Real time graphic representation

Event and alarm monitoring

Dynamic adaptation to different screen resolutions

Multi touch support for mobile platforms

Multiple monitor support

Web-based reporting services

Advanced reporting options

Operator Client

Integrated graphic object library

Creating a special graphic library object

The size, position, color and captions of the objects,

relate to tags

Intelligent and customized object opportunity with script support

Layered object architecture

Different layer views for different zoom levels

Multi-user development infrastructure

Real-time graphics and trend drawings

Advanced label and communication channel management

infrastructure

Database instant query denition and results and objects

relate Page and object-based user right

GIS integration with Google Maps

SCADA Development Editor

Unlimited number and variety of alarms for a label

Conrm alarm and add conrmation note

Alarm history and instant alarm views

Show alarm alerts on objects

Access to the relevant station from the alarm page

User alarm subscriptions

Audible and visual alarm alert

Alarm e-mail sending

Color of instant alarms according to alarm approval status

Ability to add instant alarm panel to operator screens freely

Alarm Management

256 different user authority levels

User groups with different levels of authority

User specic alarm subscription

Email notication

Guest, administrator and standard user congurations

User Management

ViewPLUS SCADA

Innovation in Automation

ViewPLUS SCADA

Innovation in Automation

MDS-Lite

I/O Label Count

Virtual Label Count

Maximum Client Count

Graphics

Web Server

JSON Message Support

MSCADA Message Support

SQLite Database

Reporting

PGSQL Database

Development

MDS-10C-

150T

MDS-20C-

500T

MDS-50C-

2000T

MDS-100C-

10000T

MDSEnterprise

100 100 100 100 100 100

20 150 500 2000 10000

1 10 20 50 100

20 150 500 2000 10000

20 150 500 2000 10000Maximum Alarm Count

- - - - -

ODBC / MS SQL Database - - -

E-Mail Support

Redundant SCADA

Page Count Addable 5

Number of Symbols Addable per Page 400040004000400040

Server Side Reporting 400040004000400040

Client Side Reporting

Trend History

Alarm Logs

Event Logs

Version Control Integration

Script Support MDVScript MDVScript MDVScript MDVScript MDVScript MDVScript

Recipes

MikrodevBUS

MODBUS

Protocol

Support

ODBC / MS SQL Database

IEC 60870-5-101**

IEC 60870-5-104**

DNP 3**

*** *** *** *** *** ***

*** *** *** *** *** ***

*** *** *** *** *** ***

Double License Use

OPC Server *** *** *** *** *** ***

SNMP** *** *** *** *** *** ***

*** *** *** *** *** ***

Panel

Multi Platform Support (Windows,

Linux, MacOs, Android, IOS)

Integrated Symbol Object Count

User Symbol Addition Interface

ViewPLUS

SCADA

Server

Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes

Yes

Yes Yes Yes

Unlimited*

Unlimited*

Unlimited*

Unlimited*

Unlimited*

Unlimited*

Unlimited*

Unlimited*Unlimited*Unlimited*Unlimited*

*Processor Constraints might apply depending on available hardware elements such as power, memory.

** MODBUS protocol support is delivered free of charge for all SCADA packages. Other protocols are provided separately than

corresponding SCADA packages.

***Please contact with our sales channels for price information.

1x Ethernet Port (Galvanic Isolation)

Integrated GSM, 3G Communication Port

2xRS485 Port (Galvanic Isolation)

or 1xRS232 1xRS485 (Galvanically Insulated)

RTU300 Series

MODBUS TCP/RTU/TUNNEL

DNP3IEC61850

IEC60870-5-101

IEC60870-5-103

IEC60870-5-104

IEC62056-21

MQTT

SNMP

RTU300 Series Supported Protocols

IE

C 6

0870

-5-1

01

MO

DB

US

COMMUNICATION

RTU SERIES

MQTT

-104-507806 CEI

3PND

Innovation in Automation

PRODUCT CODES

*20 tags can communicate with only one IEC61850 IED

** Galvanic isolated 8 channel analog input (16 Bit ADC), 2xRS485 serial port

***This product is produced with a plastic case unless otherwise requested.

RTU SERIES

Product code

RTU310

RTU320

Ethernet MODBUSRS485 /RS232

RTU330

RTU335***

RTU340

RTU350

IEC60870-5 101

DNP3IEC60870-5 104

IEC 61850

Yes

Yes

Yes

Yes

Yes

Yes

Yes Yes

Yes

Yes

Yes

Yes

Yes

1

1

1

1

1

1

1/1

1/1

1/1

2/0

1/1

1/1

.

.

.

.

.

.

.

. .

RTU300 Series

Yes

Yes

Yes

Yes

Yes .

GSM

3G

3G

3G

3G

3G

3G

IEC62056-21

.

Yes

.

Yes

Yes

.

RTU312** Yes Yes3G 1 1/1 . . . .

RTU301 Yes1 1/1 . .3G .Yes*

MQTT

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes Yes

Yes

IEC60870-5 103

.

.

.

.

.

.

.

Yes

.

Innovation in Automation

PLC and EXPANSION MODULES

IEC 61131-3 Standard Instructions

Function Block Diagram (FBD) and Ladder Programming

Motion Control Function Library

PID and On-off Control Function Library

HVAC Systems Function Library

Programmable Data Recording (Logging)

Quick and Easy Programming

Fast Counter Input; 4 Channels, 100 kHz

Pulse Width Modulation; (PWM) 4 Channels, 200 kHz

Pulse Train Exit (PTO); 4 Channels, 50 kHz

Motor Control Capabilities

Ethernet; 1 port, 10/100 Mbps

485; 1 port, 3 kV ESD protection, Galvanic Isolation

232; 1 port, Optical Isolation*

USB; 1 port, type B mini USB**

Entegre GSM/GPRS

Integrated Communication Ports

Expandable up to 512 points***

Suitable for Hot Swap system

IO Expansion Capability

Micro SD Card Support*

Programmable Data Record Trigger Blocks

Data Logger-Data Recording Feature

SMS Receiving and Analysis Functions

Creating and Sending Many Different SMS

functions

Search DTMF Initiation and DTMF Code Sending

functions

Special GSM Functions

Supported Master Protocols; MODBUS TCP,

MODBUS RTU, MODBUS RTU Over TCP

Supported Slave Protocols; MODBUS TCP,

MODBUS RTU, MODBUS RTU Over TCP

Ability to work like MODBUS Gateway

Mikrodev Private; DEVNET (UDP Based Data Communication

Protocol

IoT Protocols; MQTT

IP Protocols; TCP, UDP, NTP, SNTP, HTTP,TFTP, DHCP, DNS

Communication Protocols

GSM; GSM/GPRS, Class 12, Quad Band

Wi-Fi; (IEEE 802.11 b/g/n)*

Optional Communication Ports

Internal Real Time Clock

Real Time Clock

* Available in the MP211 product family

** MP211 product family uses B type USB for programming

***MP211 product family knows expanding up to 1024 points

Innovation in Automation

PLC and EXPANSION MODULES

. 1 4 4 2

2 GSM 1 4 4

1 4 4 2

MP110

MP110G

MP110E ETHERNET

OPTIONALINTERFACE

PRODUCT DO DI AIRS485

MP110EG ETH, GSM 21 4 4

PRODUCT CODES

PRODUCT

XIO110.DI16

XIO110.DO16

XIO110.DI8DO8

XIO110.R8

XIO110.AI8

XIO110.AO8

XIO110.AI4AO4

XIO110.P6

XIO110.T4

XIO110.LC2

8 Channel Analog Input(Optically isolated, 0-10V or 0-20 mA, 1% Accuracy)+-

8 Channel Analog Output(Optically isolated, 0-10V or 0-20 mA, 1% Accuracy)+-

6 Channel RTD Input(Optically isolated, PT100, PT1000 or NTC, 1% Accuracy)+-

16 Channel Digital Input(Optically isolated, 0-50 VDC Input Range)

16 Channel Digital Output(Optically isolated, 2A @ 0-30 VDC Output Range)

8 Channel Relay Output(5A @ 250 VDC, NO Contact)

8 Channel Digital Input, 8 Channel Digital Output(Optically isolated, 0-50 VDC Input Range, 2A @ 0-30 VDC Output Range)

4 Channel Analog Input, 4 Channel Analog Output(Optically isolated, 0-10V or 0-20 mA, 1% Accuracy)+-

4 Channel Thermocouple(Optically isolated, J / K / R / S / T / E / B / N Type Thermocouple, 1% Accuracy)+-

2 Channel Load Cell(Optically isolated, 4/6 wired, 32 Bit Resolution, 1% Accuracy)+-

Innovation in Automation

User-friendly conguration software

Conguration over TCP / IP

Conguration via USB

Device search feature on the network

Remote rmware update

Data monitoring with Web Server feature

IO conguration and expansion

Add / remove I / O modules

I / O copy mode feature

Hot Swap feature

Conguration and Management

Ethernet; 1 port, 10/100 Mbps

RS485; 1 port, 3 kV ESD protection, galvanic isolation

RS232; 1 port, optical isolation

USB; 1 port, USB type B

Integrated Communication Ports

Integrated I / O

Digital input; 4 pieces, optical isolation

Digital output; 4 pieces 2A@30VDC, optically isolated

Analog input; 2 pieces 0-20mA, sensitivity 1%

Communication Protocols

Master communication protocols; MODBUS RTU, MODBUS TCP

IoT protocols; MQTT

IO Expansion Capability

Expandable up to a maximum of 1024 points

Optional Communication Ports

Ethernet; 1 port, 10/100 Mbits

GSM; GSM/GPRS, Class 12, Quad Band

Wi-Fi; IEEE 802.11 b/g/n

RF; 868 MHz free frequency bands, Tx power

Up to 0.5W

REMOTE I/O

Innovation in Automation

REMOTE I/O

PRODUCT CODES

PRODUCT RELAY

RIO211E

RIO211EG

RIO211EW

4ETH

ETH, GSM

ETH, Wi-Fi

AI AO DI DO RTD

4

4

2

2

2

16

16

16

8

8

8

2

2

2

4

4

4

RIO211RF ETH, RF 4 2 16 2 48

XIO211.DI16

XIO211.DO16

XIO211.DI8DO8

XIO211.R8

XIO211.AI8

XIO211.AO8

XIO211.AI4AO4

XIO211.P6

XIO211.T4

XIO211.LC2

8 Channel Analog Input(Optically isolated, 0-10V or 0-20 mA, 1% Accuracy)+-

8 Channel Analog Output(Optically isolated, 0-10V or 0-20 mA, 1% Accuracy)+-

6 Channel RTD Input(Optically isolated, PT100, PT1000 or NTC, 1% Accuracy)+-

16 Channel Digital Input(Optically isolated, 0-50 VDC Input Range)

16 Channel Digital Output(Optically isolated, 2A @ 0-30 VDC Output Range)

8 Channel Relay Output(5A @ 250 VDC, NO Contact)

8 Channel Digital Input, 8 Channel Digital Output(Optically isolated, 0-50 VDC Input Range, 2A @ 0-30 VDC Output Range)

4 Channel Analog Input, 4 Channel Analog Output(Optically isolated, 0-10V or 0-20 mA, 1% Accuracy)+-

4 Channel Thermocouple(Optically isolated, J / K / R / S / T / E / B / N Type Thermocouple, 1% Accuracy)+-

2 Channel Load Cell(Optically isolated, Loadcell, 1% Accuracy)+-

PRODUCT

Innovation in Automation

OPTIONALINTERFACE

IOT GATEWAY

GENERAL FEATURES

Conguration and Management

User-friendly conguration software (Assistant)

Conguration over TCP / IP

Conguration via USB

Device search feature on the network

Remote rmware update

Monitoring the settings with the Web Server feature

Matching the M-BUS address map and MODBUS table

Matching OBIS codes and modbus addresses

MODBUS TCP Master with RS485 / RS232 MODBUS RTU Slave

MODBUS RTU over TCP (MODBUS TUNNEL)

MODBUS TCP Slave with RS485/RS232 MODBUS RTU Master

Protocols and Networking Gateway

Integrated Communication Ports

1 port RS485, 3 kV ESD protection, 1 port RS232 or

2 port RS485

1 port B type mini USB

TCP socket type on Modbus TCP Slave Side; Server or

Client

Connection control and automatic reconnection

TCP Socket Extra Features

Communication Protocols

Master Communication Protocols; MODBUS RTU, MODBUS TCP

Slave Communication Protocols; MODBUS RTU, MODBUS TCP

Power: 1 LED Constant Green

System: 1 LED 1Hz Green

Connection: 1 LED 2Hz Green

LED Signals

Maximum Number of Connections

Server socket number; 2

Number of client sockets per server; 16

GSM; GSM/GPRS, Class 12, Quad Band

Ethernet; 10/100 Mbits

Wi-Fi; 802.11b/g/n

Optional Communication Ports

Supply voltage; 9...36 VDC

Supply Current; 50 mA @ 24 VDC

Supply

MODBUS TCP

MDC100

DLMS/COSEM

IEC62056-21

Electric meter1.

32.

SC100

TransparentCommunication

MMS100

M-BUS

Water, Natural Gas,Heat Calorimeters

1.

32.

MBS100

MODBUS RTU

MODBUS RTU Slave1.

MODBUS RTU Slave247.Electric meter Water, Natural Gas,Heat Calorimeters

Innovation in Automation

Screen Type; 7 "TFT LCD

Color; 65536

Resolution; 800x480

Touch panel type; 4 wires capacitive

Large and bright screen

Quick start

High strength

Data visualization with animation and graphics

Large symbol library

Horizontal / vertical screen support

Video format support; MPEG1, MPEG2, WMV

Screen

Connection with Many Different Devices

Remote Monitoring with Mobile Devices

Ethernet Multiple Connection

Transfer MikroSCADA Projects Quickly and Easily

Connection

Panel Mount

compatibility

Easy Data Transfer

CE Certication

Low Energy Consumption

Easy Setup

Programmable with Microdiagram

Mikrodev Expansion via CANBUS with IO Cards

Seamless Integration

MDScript Support

PLC Mode Resolution; 800x480

Color; 65536

Touch Panel Type; 4 Wire Resistive

Processor; ARM Cortex-A8 1Ghz 3D Graphics Core

SD Card Slot

The amount of memory you use; 96 MB Flash Disk

Hardware Features

OPERATOR PANEL - HMI

USB Host

Ethernet; 10/100/1000 Mbps

1 USB port

1 RS485 3 Kv ESD protection galvanic isolation

1 RS232

CANBUS

Communication Ports

PRODUCT

ViewSmart700 1 .

ETHERNET

PRODUCT CODES

RS485RS232FINGER PRINT

READER

PLCFEATURE

1 1 .

SIZE

7''

ViewSmart710 11 17'' Yes Yes

Alarm Monitoring and Analysis

Log Recording via SD Card

Connect with Mikrodev ViewPLUS Client

FTP Server

Information / Data

Input Power; 24 VDC

Power Isolation

Power consumption; @ 400mA 24V

Operating temperature; -20 ~ 60 C

Other

Innovation in Automation

www.mikrodev.com

Innovation in Automation

MIKRODEV has been developing and producing

industrial control and communication products since

2006.

MIKRODEV provides services to system integrators

in the public and private sectors,OEMs and end users.

Our products are manufactured in accordance with the

quality standards required by the industrial automation

sector and our products have been proved by the quality

of our products for many years without problems.

MIKRODEV is one of the few companies in the

world with its own designed IEC 61131-3 compliant

library in its programmable logic controllers. In addition,

an open, exible, programmable SCADA solution has

been developed by MIKRODEV and is available to the

customers.

The performance, wide range of applications

with MIKRODEV products and the company's technologi-

cal know-how, helps customers achieve faster, easier and

lower cost results.

Head Ofce : Cumhuriyet Mh. Turgut Özal Cd. No:26 41420

Çayırova Gebze / KOCAELİ

Phone: 0262 653 56 68 / 0262 643 56 68

0262 642 93 87 Fax: 0262 653 56 68

E-mail: [email protected]

Branch : T Ü BİTAK Mam. Gebze Yerleşkesi

Teknoloji Geliştirme Bölgesi 41700 D Blok

No: 37 Gebze - KOCAELİ

Gebze - KOCAELİ

Phone: 0262 653 56 68 / 0262 643 56 68

0262 642 93 87 Fax: 0262 653 56 68

United Kingdom : Mikrodev UK LOMBARD BUSINESS PARK,

Suite 23, 12 Deer Park Road, Wimbledon,

London SW19 3TL United Kingdom

Phone: +44 7502 259465

[email protected]:

South Africa : GRANVILLE PLACE SANDTON

GAUTENG 2090

South Africa

Phone: +27 76 717 4475 / +27 62 981 6096

Branch

Branch