Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically … · 2016-07-19 · Device...

15
Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically sick patient R. D. Yadave. MD.DM. Sr. Consultant & Student Interventional Cardiology & Electrophysiology Batra Hospital ,New Delhi. India. Prabhat Kumar, MD.DM. Heart Hospital .Patna.India.

Transcript of Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically … · 2016-07-19 · Device...

Page 1: Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically … · 2016-07-19 · Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically sick patient R. D.

Device closure of Ruptured Sinus of Valsalva Aneurysm in

a critically sick patient

R. D. Yadave. MD.DM.

Sr. Consultant & Student

Interventional Cardiology & Electrophysiology

Batra Hospital ,New Delhi. India.

Prabhat Kumar, MD.DM.

Heart Hospital .Patna.India.

Page 2: Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically … · 2016-07-19 · Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically sick patient R. D.

Disclosure Statement of Financial Interest

I, (Dr.R.D.Yadave) DO NOT have a financial interest/arrangement or affiliation with one or more organizations that could be perceived as a real or apparent conflict of interest in the context of the subject of this presentation.

Page 3: Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically … · 2016-07-19 · Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically sick patient R. D.

History and Physical Examination

Thirty year old male presented with chest pain, •palpitation and severe breathlessness. He was in shock with features of severe CHF in a gasping stage.

His pulse was 170 bpm, BP 70mm Hg systolic, •Resp rate 25 /min gasping , JVP raised . Cardiomegaly with continuous murmur heard at lower left sternal border.

Chest – B/L fine crepts with prolonged expiration •and ronchi.

Liver enlarged 10 cm below costal margin and •tender .

Page 4: Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically … · 2016-07-19 · Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically sick patient R. D.

Investigation

ECG showed VT 170 bpm with RBBB and •left axis deviation morphology.

X-ray chest showed massive cardiomegaly •with increased Qp and severe PVH.

Echo showed LA, LV and RV volume •overload along with RSOV aneurysm of non coronary sinus to RA .Size of defect was 10-12 mm with continuous Left to Right shunt.

Page 5: Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically … · 2016-07-19 · Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically sick patient R. D.

Procedure of device closure

Patient was given IV amiodarone 150 mg •IV and DC verted by 200 Joule Biphasic energy .

Shifted to cath lab . Arterio venous loop •of Extra support wire was made from Aortic root through RSOV to RA and wire was snared out from RA to Right femoral vein .

Page 6: Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically … · 2016-07-19 · Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically sick patient R. D.

10 F Delivery sheath was sheathed in in •Descending aorta. 16 mm Amplatzer like PDA device (Heart –R PDA occluder from LifeTech)was loaded and delivered across RSOV and complete closure was achieved immediately.

Page 7: Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically … · 2016-07-19 · Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically sick patient R. D.
Page 8: Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically … · 2016-07-19 · Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically sick patient R. D.
Page 9: Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically … · 2016-07-19 · Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically sick patient R. D.
Page 10: Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically … · 2016-07-19 · Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically sick patient R. D.
Page 11: Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically … · 2016-07-19 · Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically sick patient R. D.
Page 12: Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically … · 2016-07-19 · Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically sick patient R. D.
Page 13: Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically … · 2016-07-19 · Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically sick patient R. D.

Patient had remarkable •hemodynamic and clinical recovery and asymptomatic over one year of clinical follow up .

Follow up Echo showed LA, LV size •normalized .No shunt across the device seen. No AR.

Page 14: Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically … · 2016-07-19 · Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically sick patient R. D.

Conclusion and Take home message

Although surgical treatment is the •standard therapy of RSOV aneurysm but can be treated successfully by interventional technique even in critically sick patient and life can be saved.

This interventional technique should be •the treatment of choice in current scenario.

Page 15: Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically … · 2016-07-19 · Device closure of Ruptured Sinus of Valsalva Aneurysm in a critically sick patient R. D.