    Deep Eutectic Salt Formulations Suitable as

     Advanced Heat Transfer FluidsJustin W. Raade, PhD

    Halotechnics, Inc.

     [email protected]

    May 26, 2010

     Award No. DE-FG36-08GO18144CSP

    This presentation does not contain any proprietary, confidential, or otherwise restricted information

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    2/20

    2 | Solar Energy Technologies Program Halotechnics, Inc. eere.energy.gov

    Overview

    • Project start date: January 1,2009

    • Project end date: December31, 2011

    • Percent complete: 34%

    • This project will enable the cost ofCSP electricity to be reduced by15%. We are developing a heattransfer fluid that will allow hightemperature operation of CSPplants.

    • Total project funding

     – DOE share: $1.5 million

     – Contractor share: $564,000

    • Funding received in FY09:$500,000

    • Funding for FY10: $500,000

    Timeline

    Budget

    Barriers

    Partners• Halotechnics, Inc.

    • Sandia National Laboratories willpartner in Phase 3 for field testing.

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    3/20

    3 | Solar Energy Technologies Program Halotechnics, Inc. eere.energy.gov

    Background and objective

    • Concentrating Solar Power (CSP)is lowest cost solar electricity

     – 13-17 ¢/kWh

    • Must reduce cost of CSP tocompete with fossil fuels

    Novel materials needed for heattransfer fluid (HTF) and thermalenergy storage (TES)

    HTF

    TES

    Project Objective: Conduct

    an R&D program focusing ondeep eutectic (low-melting)

    salt formulations suitable as

    advanced heat transfer fluids

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    4/20

    4 | Solar Energy Technologies Program Halotechnics, Inc. eere.energy.gov

    Project milestones

    • Milestone 1: Approximately 250 (100 minimum) primary candidate formulationsCandidates must meet the following criteria:

     – freezing point less than 80°C (100°C maximum)

     – thermal stability as a liquid to about 500°C (450°C minimum)

    • Milestone 2: Approximately 10 (5 minimum) secondary candidate formulations.Candidates must meet the following criteria:

     – viscosity of about 1 centipoise (10 centipoise maximum) to about 500°C

     – vapor pressure of about 5 atmospheres (10 atmospheres maximum) to about 500°C

     – specific gravity in the range of 0.7-1.7 (0.5 minimum, no maximum) to about 500°C

     – heat capacity in the range of 2-5 J/g/K (1 J/g/K minimum, no maximum) to about 500°C

    • Milestone 3: At least 1 commercial production candidate. Candidate(s) must meetthe following criteria (as determined by field testing at Sandia):

     – sufficient pumpability

     – thermal cycling tolerance

     – sufficient long-term thermal stability

     – chemical compatibility with common stainless steels

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    5/20

    5 | Solar Energy Technologies Program Halotechnics, Inc. eere.energy.gov

    Project timeline

    Status May 2010

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    6/20

    6 | Solar Energy Technologies Program Halotechnics, Inc. eere.energy.gov

    Materials discovery workflow

    Powdernium powderdispensing robot 

    Parallel Melting PointWorkstation (PMP) with

    96 channel capability 

    High temperaturefurnace formelting/mixing 

    • Symyx software and R&D tools enable automatedworkflow

    • Maximum throughput of 500 blends/week• High throughput workflow can be leveraged to

    develop advanced materials similar to HTF suchas thermal energy storage materials

     Automation Studio tocreate experiments andmanage data

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    7/207 | Solar Energy Technologies Program Halotechnics, Inc. eere.energy.gov

    Thermal properties characterization

    • Thermal stability

     – High temperature thermogravimetricanalysis (TGA)

     – TA Instruments Q500 with 16position autosampler 

    • Heat capacity – Differential scanning calorimeter

    (DSC)

     – TA Instruments Q200 with 50position autosampler 

    • Viscosity

     – Brookfield viscometer (to beacquired)

     – Capable of testing up to 300 °C,may modify for higher temperature

    • Molten salt chemistry

     – Symyx Low Thermal Mass Reactorfor testing salts up to 500 °C

    TGA with 16 position

    autosampler 

    DSC with 50 position

    autosampler 

    High temperature

    viscometer 

    Low Thermal Mass Reactor 

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    8/208 | Solar Energy Technologies Program Halotechnics, Inc. eere.energy.gov

    Milestone and results

    Milestone 1: Approximately 250 (100minimum) primary candidate formulations

    • Candidates must meet the following criteria:

     – freezing point less than 80°C (100°Cmaximum)

     – thermal stability as a liquid to about 500°C

    (450°C minimum)

    Meltingpoint

    Thermalstability

    Primary candidate

    formulations

    Primary screen

    189

    5030

    138

    5030 blends screened for melting point189 blends met melting target 500 °C

    Phase 1 results

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    9/209 | Solar Energy Technologies Program Halotechnics, Inc. eere.energy.gov

    Heat transfer fluid for trough plants

    • Must increase plant operating temperature to 500 °C to increase thermalefficiency and reduce levelized cost of electricity would enable$0.02/kWh reduction according to Sandia study 

    • Current plants limited to 390 °C by synthetic oil heat transfer fluid (VP-1)

    • Existing salt-based heat transfer fluids have unacceptably high meltingpoint, typically 142 °C (Hitec), preventing any CSP applications

    • Can combine best attributes of both with “deep eutectic” salt formulations high thermal stability of salt with low melting point of synthetic oil

    Recent breakthrough: Discovered formulations with melting

     point less than 75 °C and thermal stability to 500 °C 

    6005004003002001000 °C

    synthetic oil 

    traditional salt 

    Halotechnics Solar Salt  Patent Application No. 61325725 

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    10/2010 | Solar Energy Technologies Program Halotechnics, Inc. eere.energy.gov

    Deep eutectic salt formulations

    • Eutectic salt formulations exhibit low melting points

    • Screened over 5000 unique blends of nitrates, nitrites, and other salts

    • Discovered many eutectic blends with melting points below 75 °C

    • Large number of possible salt formulations is a combinatorial problem andsignificant barrier to entry

    Binary mixture Ternary mixture Quaternary mixture High order mixtures

    Na + K = 220 °C Binary + Li = 120 °C Ternary + Ca = 90 °C Quaternary +++ = 75 °C

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    11/2011 | Solar Energy Technologies Program Halotechnics, Inc. eere.energy.gov

    Thermal stability

    • Blends containing nitrite are susceptible to oxidation in air 

    • TGA screening method produces relative ranking of thermal stabilityof blends, not absolute measurement

    • Long term field testing is planned for Phase 3

    TGA thermal stability behavior of Hitec nitrate-onlyblend in air and nitrogen.

    TGA thermal stability behavior of Hitec nitrate/nitriteblend in air and nitrogen.

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    12/2012 | Solar Energy Technologies Program Halotechnics, Inc. eere.energy.gov

    Data flow

    CONSTRAINTS• Cost• Safety• Stability• Previous results

    EXPERIMENT DESIGN

    DATA ANALYSIS

    Library Studio Screening workflow  Data

    FEEDBACK 

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    13/2013 | Solar Energy Technologies Program Halotechnics, Inc. eere.energy.gov

    Baseline Li-Na-K-NO3 system

    Typical PMP data All values in mol%

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    14/2014 | Solar Energy Technologies Program Halotechnics, Inc. eere.energy.gov

    Visualization of quaternary phasespace

    • Each end face of triangular prism is ternarysystem (Li-Na-K-NO3 and Li-Na-K-NO2 inthis example)

    • Plot series of cross sections at constant NO2level to visualize melting point data

    Li

    Na

    K

    40%

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    15/2015 | Solar Energy Technologies Program Halotechnics, Inc. eere.energy.gov

    Visualization of quinary phase space

    ion 5 

    ion 6 

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    16/2016 | Solar Energy Technologies Program Halotechnics, Inc. eere.energy.gov

    Visualization of 7 ion phase space

    Ion 5 

    ion 6 

    Ion 5 

    ion 5 

    ion 7 

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    17/20

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    18/2018 | Solar Energy Technologies Program Halotechnics, Inc. eere.energy.gov

    From lab to plant

    • Next phases will build upon successof Phase 1 (2009) to transfertechnology from the lab to field testing

    • Phase 2 (2010) focus on secondaryscreening for other desirableproperties

    • Phase 3 (2011) focus on blendoptimization and field testing withSandia National Laboratories

    • Will work closely with customers totest HTF in pilot plants before full

    scale deployment

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    19/2019 | Solar Energy Technologies Program Halotechnics, Inc. eere.energy.gov

    From lab to plant

    R&DComponent

    testingSystemtesting

    Pilot plantCommercial

    plant

    1-10 g 10 kg 1000 kg 100 tons 10,000 tons

    Must work with leadingCSP technology

    developers to bringHTF from lab to plant 

  • 8/18/2019 Deep Eutectic Salt Formulations Suitable as Advanced Heat Transfer Fluids

    20/2020 | S l E T h l i P H l t h i I

    Summary

    • Halotechnics has developed a novel salt mixture suitable for use as a heattransfer fluid in CSP plants, increasing their efficiency and reducing theircost

    • The heat transfer fluid has a broad operating range (75 °C to 500 °C)

    • Halotechnics will continue to optimize and field test the heat transfer fluid

    with industry partners in order to bring the material to market