Datalogger Lubrication Monitor Specifications INTRODUCING LINCOLN

4
INTRODUCING LINCOLN’S NEW PRODUCT LINEUP FOR THE NATURAL GAS COMPRESSION INDUSTRY INTRODUCING LINCOLN’S NEW PRODUCT LINEUP FOR THE NATURAL GAS COMPRESSION INDUSTRY Datalogger Lubrication Monitor CELEBRATING A CENTURY OF INNOVATIVE SOLUTIONS Datalogger Lubrication Monitor Cycle Switch Stand-Alone Cycle Switch with Shut Down Feature

Transcript of Datalogger Lubrication Monitor Specifications INTRODUCING LINCOLN

Lincoln Industrial Corp.One Lincoln WaySt. Louis, MO 63120-1578

Phone 314.679.4200Fax 314.679.4359www.lincolnindustrial.com

Form 444050 (05/10)© Copyright 2010Printed in U.S.A.

INTRODUCING LINCOLN’S NEWPRODUCT LINEUP FOR THE NATURALGAS COMPRESSION INDUSTRY

INTRODUCING LINCOLN’S NEW PRODUCT LINEUP FOR THE NATURALGAS COMPRESSION INDUSTRY

Datalogger Lubrication Monitor

CELEBRATING A CENTURY OF INNOVATIVE SOLUTIONS

Datalogger Lubrication Monitor Cycle Switch

Stand-Alone Cycle Switch with Shut Down Feature

Ordering InformationOrdering Information249123 Hall Effect/Cycle Switch with Shutdown for Lincoln MC2-HP series blocks249124 Hall Effect/Cycle Switch with Shutdown for Lincoln UV and Graco Lubriquip®-Manzel MHP series style block87630 Single or Dual Lincoln Datalogger Monitor249120 Hall Effect Cycle Switch for Lincoln MC2-HP series blocks249122 Hall Effect Cycle Switch for Lincoln UV and Graco Lubriquip®-Manzel MHP series style block 250001 Wall Mounting Bracket for 87630249125 EX Housing, Rated Class 1, Div 1 and 2, Group B, C, D87617 Reed Type Cycle Switch for Lincoln MC and MC2-HP series blocks

Cycle Switch & Cycle Switch with Shut Down Feature SpecificationsCycle Switch & Cycle Switch with Shut Down Feature SpecificationsPower Requirement: 5 TO 30 VDC, 100 UA max.Maximum Working Pressure: 7500 psi Temperature Range: -40°C TO + 85°C (-40°F TO + 185°F)Materials: Aluminum Housing, Stainless Steel �Magnet AssemblyEX Rating Approval pending for Class I, Groups A, B, C & D, Div. 1 & 2 CE, II 3G Ex Na IIA

Datalogger Lubrication Monitor SpecificationsDatalogger Lubrication Monitor SpecificationsInput Power 10-30 VDC 0.25 AMP Max.Internal Battery: 3.6V Long-Life Lithium Tardiran TL-5930, battery life 4 – 6 yearsOutput Switches: 2 each open drain sinking FET’s, rated 30 VDC 500mA max.Ambient Temp. Range: Operation, -40° to +85°C (-40° to 185°F), LCD -20°C to 70C, USB Download 0C to 70CDisplay: 2x16 backlit characterInput Cycle Range: 5 to 300 secondsUnits of Measure: Pints, liters or gallons Alarm Time: Adjustable from 5 to 300 secondsSwitch Response Time: 250mS maxUSB Download Port USB 2.0 compliant, accepts universal flash driveData Log File Format: Comma-Separated Values File (CSV) for use in programs including Microsoft® ExcelEX Rating Approval pending for Class I, Groups A, B, C & D, Div. 2 CE, II 3G Ex Na IIA

Cycle Indication Light

Captured Magnet

Cycle Indication Light

Captured Magnet

Datalogger shown with optional mounting bracket

LINCOLN’S TWO NEW CYCLE SWITCHESFOR NATURAL GAS COMPRESSORSLINCOLN’S TWO NEW CYCLE SWITCHESFOR NATURAL GAS COMPRESSORS

LINCOLN’S NEW DATALOGGER LUBRICATION MONITOR

LINCOLN’S NEW DATALOGGERLUBRICATION MONITOR

DOWNLOAD YOUR DATA TO A FLASH DRIVE FROM A CONVENIENT ACCESS POINT AWAY FROM HEAT AND WITHOUT AN EXPENSIVE PDA.

Innovative solution designed to protect your compressors against untimely lubrication faults or “no flow” conditions• Three mounting options

– Compressor Panel consolidates compressor controls– Wall Mount offers convenient access to mechanics/operators– EX (optional Div I explosion-proof enclosure)

• Two primary power sources available – 24 VDC for maximum reliability (with battery backup) – Powerful, long-life Lithium battery (included)

• Continuously monitors the packing and cylinder lubrication system – Automatically records warnings, faults and reprogramming events

• Download feature allows history to be transferred to a CSV report via a USB flash drive in less than a minute

• Store data for up to one year

• No special software or hand-held hardware device needed

• One model will monitor either a single or dual lubrication system

• Designed for use with Reed or Hall effect cycle switches

• Designed to work with Lincoln MC, MC2 HP valves as well as with other brands

• Captured magnet assembly

• Simple installation reduces labor costs.

• Hall effect switch

Cycle Switch For Use With The Datalogger Lubrication Monitor• For use with the Datalogger

Lubrication Monitor

• The industry’s FIRST cycle switch with a cycle indicator light

• Lower-cost, stand-alone solution

• Shut down protection for “no-flow” conditions is factory set at two minutes

• Operates from 5-30 VDC for increased reliability

Cycle Switch with Shutdown Feature for Reliable “No-Flow” Protection

Cycle Indication Light

Captured Magnet

Cycle Indication Light

Captured Magnet

Datalogger shown with optional mounting bracket

LINCOLN’S TWO NEW CYCLE SWITCHESFOR NATURAL GAS COMPRESSORSLINCOLN’S TWO NEW CYCLE SWITCHESFOR NATURAL GAS COMPRESSORS

LINCOLN’S NEW DATALOGGER LUBRICATION MONITOR

LINCOLN’S NEW DATALOGGERLUBRICATION MONITOR

DOWNLOAD YOUR DATA TO A FLASH DRIVE FROM A CONVENIENT ACCESS POINT AWAY FROM HEAT AND WITHOUT AN EXPENSIVE PDA.

Innovative solution designed to protect your compressors against untimely lubrication faults or “no flow” conditions• Three mounting options

– Compressor Panel consolidates compressor controls– Wall Mount offers convenient access to mechanics/operators– EX (optional Div I explosion-proof enclosure)

• Two primary power sources available – 24 VDC for maximum reliability (with battery backup) – Powerful, long-life Lithium battery (included)

• Continuously monitors the packing and cylinder lubrication system – Automatically records warnings, faults and reprogramming events

• Download feature allows history to be transferred to a CSV report via a USB flash drive in less than a minute

• Store data for up to one year

• No special software or hand-held hardware device needed

• One model will monitor either a single or dual lubrication system

• Designed for use with Reed or Hall effect cycle switches

• Designed to work with Lincoln MC, MC2 HP valves as well as with other brands

• Captured magnet assembly

• Simple installation reduces labor costs.

• Hall effect switch

Cycle Switch For Use With The Datalogger Lubrication Monitor• For use with the Datalogger

Lubrication Monitor

• The industry’s FIRST cycle switch with a cycle indicator light

• Lower-cost, stand-alone solution

• Shut down protection for “no-flow” conditions is factory set at two minutes

• Operates from 5-30 VDC for increased reliability

Cycle Switch with Shutdown Feature for Reliable “No-Flow” Protection

Lincoln Industrial Corp.One Lincoln WaySt. Louis, MO 63120-1578

Phone 314.679.4200Fax 314.679.4359www.lincolnindustrial.com

Form 444050 (05/10)© Copyright 2010Printed in U.S.A.

INTRODUCING LINCOLN’S NEWPRODUCT LINEUP FOR THE NATURALGAS COMPRESSION INDUSTRY

INTRODUCING LINCOLN’S NEW PRODUCT LINEUP FOR THE NATURALGAS COMPRESSION INDUSTRY

Datalogger Lubrication Monitor

CELEBRATING A CENTURY OF INNOVATIVE SOLUTIONS

Datalogger Lubrication Monitor Cycle Switch

Stand-Alone Cycle Switch with Shut Down Feature

Ordering InformationOrdering Information249123 Hall Effect/Cycle Switch with Shutdown for Lincoln MC2-HP series blocks249124 Hall Effect/Cycle Switch with Shutdown for Lincoln UV and Graco Lubriquip®-Manzel MHP series style block87630 Single or Dual Lincoln Datalogger Monitor249120 Hall Effect Cycle Switch for Lincoln MC2-HP series blocks249122 Hall Effect Cycle Switch for Lincoln UV and Graco Lubriquip®-Manzel MHP series style block 250001 Wall Mounting Bracket for 87630249125 EX Housing, Rated Class 1, Div 1 and 2, Group B, C, D87617 Reed Type Cycle Switch for Lincoln MC and MC2-HP series blocks

Cycle Switch & Cycle Switch with Shut Down Feature SpecificationsCycle Switch & Cycle Switch with Shut Down Feature SpecificationsPower Requirement: 5 TO 30 VDC, 100 UA max.Maximum Working Pressure: 7500 psi Temperature Range: -40°C TO + 85°C (-40°F TO + 185°F)Materials: Aluminum Housing, Stainless Steel �Magnet AssemblyEX Rating Approval pending for Class I, Groups A, B, C & D, Div. 1 & 2 CE, II 3G Ex Na IIA

Datalogger Lubrication Monitor SpecificationsDatalogger Lubrication Monitor SpecificationsInput Power 10-30 VDC 0.25 AMP Max.Internal Battery: 3.6V Long-Life Lithium Tardiran TL-5930, battery life 4 – 6 yearsOutput Switches: 2 each open drain sinking FET’s, rated 30 VDC 500mA max.Ambient Temp. Range: Operation, -40° to +85°C (-40° to 185°F), LCD -20°C to 70C, USB Download 0C to 70CDisplay: 2x16 backlit characterInput Cycle Range: 5 to 300 secondsUnits of Measure: Pints, liters or gallons Alarm Time: Adjustable from 5 to 300 secondsSwitch Response Time: 250mS maxUSB Download Port USB 2.0 compliant, accepts universal flash driveData Log File Format: Comma-Separated Values File (CSV) for use in programs including Microsoft® ExcelEX Rating Approval pending for Class I, Groups A, B, C & D, Div. 2 CE, II 3G Ex Na IIA