Data Sheet - RADProductsOnline...over ATM (IMA) versions 1.0 and 1.1, allowing users to define up to...

8
The Access Company Pseudowire emulation of ATM UNI/IMA and TDM traffic over packet-switched networks, such as Layer-2, MPLS and IP Advanced pseudowire connectivity verification using VCCV-BFD messages End-to-end fault propagation between legacy and packet-switched networks Full ATM switching, scheduling, policing and shaping for separation of HSDPA and voice services Full system redundancy and modular hot-swappable architecture for replacing the interface, power and main modules while maintaining service continuity ACE-3000 Family ACE-3400 Aggregation Site Gateway Data Sheet 2G, 3G and HSDPA cellular backhauling over packet-switched networks (PSNs), SDH/SONET networks and E1/T1 transport links ACE-3400 is a multiservice carrier-class gateway, designed for cost-effective backhauling of 2G/3G voice and HSDPA data traffic over multi-generation access networks, such as Ethernet and SDH/SONET. ACE-3400 uses advanced pseudowire (PW) technology to deliver cellular and legacy traffic services (ATM, TDM) over next-generation PSNs (packet-switched networks), including Layer-2, MPLS and IP. Typically located at the RNC/BSC site, the unit converts and aggregates traffic using N × E1/T1, STM-1/OC-3c and Gigabit Ethernet interfaces. ANY-SERVICE-ANY-PORT The STM-1/OC-3c and Gigabit Ethernet interfaces operate as user or network ports, per user configuration and depending on the required application. In addition, ATM or TDM traffic received via the E1/T1 ports is converted by ACE-3400 to either ATM (UNI or IMA), CES or SAT over PSNs, depending on the originating traffic type.

Transcript of Data Sheet - RADProductsOnline...over ATM (IMA) versions 1.0 and 1.1, allowing users to define up to...

  • The Access Company

    • Pseudowire emulation of ATM UNI/IMA and TDM traffic over packet-switched networks, such as Layer-2, MPLS and IP

    • Advanced pseudowire connectivity verification using VCCV-BFD messages

    • End-to-end fault propagation between legacy and packet-switched networks

    • Full ATM switching, scheduling, policing and shaping for separation of HSDPA and voice services

    • Full system redundancy and modular hot-swappable architecture for replacing the interface, power and main modules while maintaining service continuity

    ACE-3000 Family

    ACE-3400Aggregation Site Gateway

    Data Sheet

    2G, 3G and HSDPA

    cellular backhauling

    over packet-switched

    networks (PSNs),

    SDH/SONET networks

    and E1/T1 transport

    links

    ACE-3400 is a multiservice carrier-class gateway, designed for cost-effective backhauling of 2G/3G voice and HSDPA data traffic over multi-generation access networks, such as Ethernet and SDH/SONET.

    ACE-3400 uses advanced pseudowire (PW) technology to deliver cellular and legacy traffic services (ATM, TDM) over next-generation PSNs (packet-switched networks), including Layer-2, MPLS and IP.

    Typically located at the RNC/BSC site, the unit converts and aggregates traffic using N × E1/T1, STM-1/OC-3c and Gigabit Ethernet interfaces.

    ANY-SERVICE-ANY-PORT

    The STM-1/OC-3c and Gigabit Ethernet interfaces operate as user or network ports, per user configuration and depending on the required application.

    In addition, ATM or TDM traffic received via the E1/T1 ports is converted by ACE-3400 to either ATM (UNI or IMA), CES or SAT over PSNs, depending on the originating traffic type.

  • ACE-3400 Aggregation Site Gateway

    ATM OVER PACKET CAPABILITIES

    ACE-3400 allows up to 512 data pseudowire connections to be established over a packet-switched network.

    The following encapsulation methods are supported according to RFC 4717:

    • 1-to-1 VC/VP – Each VCC/VPC is mapped to a single pseudowire connection

    • N-to-1 VC/VP – Several VCs or VPs can be encapsulated to a single pseudowire connection.

    ACE-3400 allows single or multiple ATM cells to be encapsulated per frame.

    Over L2 and L3 networks, ACE-3400 uses various encapsulation types: VLANs (virtual LANs), dynamic and static MPLS label assignment, and MPLS in IP.

    TDM OVER PACKET CAPABILITIES

    By allowing its E1/T1 interfaces to work in TDM mode (user-selectable), ACE-3400 allows 2G cellular traffic to be transported over PSNs.

    Both structure-agnostic and structure-aware modes are supported, with up to 8 bundles per E1/T1 port or 128/300 bundles in total.

    To compensate for the jitter caused by the packet-switched network, each TDM stream has a jitter buffer of up to 32 milliseconds.

    The encapsulation of TDM traffic complies with the RFC 4553 and RFC 5086 requirements.

    USING THE LABEL DISTRIBUTION PROTOCOL (LDP)

    ACE-3400 uses the MPLS label distribution protocol (LDP) to automatically assign and distribute pseudowires and tunnel labels between MPLS peers.

    Note: The LDP functionality requires a software

    license. For more information, refer to the Ordering

    section.

    ATM SWITCHING AND POLICING CAPABILITIES

    ACE-3400 provides full ATM switching capabilities, including scheduling and shaping of ATM-based traffic.

    Operators can assign each virtual connection (VC) or virtual path (VP) to a service class, define the QoS parameters and shape the ATM egress traffic. ATM traffic policing allows operators to discard, tag or count non-conformant cells per configuration.

    ACE-3400 allows establishing up to 1024 VP and VC connections with full UNI/NNI VPI and VCI ranges.

    ACE-3400 supports inverse multiplexing over ATM (IMA) versions 1.0 and 1.1, allowing users to define up to 32 or 63 IMA groups.

    Each of the unit's E1/T1 ports can be configured to work in ATM IMA, ATM UNI or TDM over ATM mode (structured/ unstructured CES). The fiber optic STM-1/OC-3c interfaces operate in ATM UNI mode.

    QUALITY OF SERVICE (QOS) OVER PSN

    Over packet-switched networks, QoS is provided according to the network type:

    • Layer-2 network – outgoing pseudowire packets are assigned a dedicated VLAN ID according to 802.1Q and marked for priority using 802.1p bits

    • MPLS network – outgoing pseudowire packets are assigned to a specific MPLS tunnel and marked for priority using EXP bits

    • IP network – outgoing pseudowire packets are marked for priority using ToS or DSCP bits.

    Figure 1. ACE-3400 in a Hybrid Backhaul Solution

  • Data Sheet

    CLOCK SYNCHRONIZATION

    ACE-3400 provides robust clock synchronization and flexible timing modes, including:

    • Interface-based synchronization – the clock is recovered from the RX traffic of a selected interface, in accordance with G.823 and depending on the network's SLA

    • Unicast clock distribution – the master clock is distributed with a dedicated stream towards up to 256 remote PSN peers

    • Multicast clock distribution – the master clock is distributed towards the PSN using a single IP multicast clock stream (IGMPv2 host).

    GENERIC ROUTING ENCAPSULATION (GRE)

    ACE-3400 encapsulates MPLS packets over GRE to establish point-to-point tunnel connection over an IP network. This tunneling service is used to transfer MPLS packets over an IP network without using the IP addressing scheme.

    E1/T1 INTERFACES

    ACE-3400 includes 32 or 63 (as ordered) E1 or T1 multiservice ports that can be configured to work in ATM UNI/IMA or TDM mode, per user configuration.

    This Any-Service-Any-Port framework enables high flexibility in deployment within various backhaul solutions.

    Optional patch panel adapters can be used to convert the E1/T1 ports terminated in six 64-pin Telco connectors. Each Telco connector supports up to 14 E1/T1 ports.

    INTERFACE MODULES

    The ACE-3400 chassis provides slots for installing up to four hot-swappable interface modules in total. An interface module's type can be either SDH/SONET or Gigabit Ethernet.

    SDH/SONET INTERFACES

    ACE-3400 supports up to three STM-1/OC-3c UNI interfaces, or up to two channelized STM-1/OC-3 interfaces:

    • The STM-1/OC-3c UNI interfaces map physical layer and ATM cells into STM-1/OC-3c (ATM-155) according to ITU I.432

    • The channelized STM-1/OC-3 interface provides up to 63 VC-12 or 84 VT1.5 channels. Each channel can be set to ATM UNI/IMA or TDM mode.

    Two SDH/SONET ports of the same type can be configured to work in automatic protection switching (APS) mode, to provide 1+1 protection according to G.841 Annex B.

    GIGABIT ETHERNET INTERFACES

    ACE-3400 supports up to two Gigabit Ethernet ports, used for pseudowire (PW) connectivity, user connections and inband management access over a single link.

    To allow reliable and uninterrupted service over packet-switched networks, two Gigabit Ethernet interfaces can be set to work in the 1:1 or 1+1 automatic protection switching modes, according to IEEE 802.3ad.

    MAIN MODULES

    The main modules of ACE-3400 affect the nature and overall functionality of the unit. Three distinct functionality types are available:

    • Delivering ATM traffic over fiber optic STM-1/OC-3c links and packet-switched networks

    • Aggregating VC-12/VT1.5 circuits over channelized STM-1/OC-3 or GbE links

    • Aggregating E1/T1 traffic (ATM UNI/IMA or TDM) over STM-1/OC-3c or GbE links.

    Accordingly, the main modules can be replaced in order to fulfill different backhauling tasks.

    Figure 2. Emulated ATM/TDM Services over a Packet-Switched Network (PSN)

  • ACE-3400 Aggregation Site Gateway

    SYSTEM REDUNDANCY

    ACE-3400 allows two identical main modules to work in redundancy mode, which protects the unit's data matrix and main CPU in cases of unexpected module reset. One main module is set as the active module, while the second is in standby mode, ready to work in place of the active one at any moment.

    OAM AND DIAGNOSTICS

    Comprehensive monitoring and diagnostic capabilities include:

    • Pseudowire connectivity check

    • External and internal physical loopbacks on STM-1/OC-3c/OC-3 ports

    • Cell test towards the ATM connections.

    ACE-3400 periodically verifies the connectivity status of pseudowire connections, using VCCV-BFD messages according to the 'draft-ietf-bfd-base' requirements. If a failure is detected, a notification is sent to both the remote peer and the ATM/TDM connection of the specific PW. This allows complete monitoring over the pseudowire connections in real-time.

    ATM/TDM and PSN port alarms are propagated over the packet-switched network from end to end. This includes the mapping of:

    • Packet-switched network alarms to ATM alarms

    • ATM/TDM alarms over the PSN to the remote customer equipment (CE)

    • Physical failures of ATM/TDM ports, over the packet-switched network towards both the local and remote CE.

    For conventional ATM cross-connects (XCs), OAM is supported according to ITU I.610 requirements:

    • F4 and F5 OAM

    • Configurable OAM mode per connection point

    • Segment/intermediate mode for user connections and end-to-end mode for the management connection

    • AIS and RDI cell detection and generation upon physical layer and ATM layer failures

    • CC cell generation and LOC state detection per VP/VC

    • Loopback location ID and configurable loopback source ID per device.

    Performance monitoring is provided by Ethernet and IP-layer network condition statistics, such as packet sequence errors (loss or misorder) and packet delay variation (jitter), which are monitored and stored by the device.

    ACE-3400 collects statistics per physical port and per connection for 15-minute intervals. Statistics for the last 6 hours are stored in the device and can be retrieved at the network management station.

    For diagnostics purposes, ACE-3400 maintains a cyclic event log file that stores up to 4096 time-stamped events. In addition, an internal system log agent can send all reported events to a centralized repository or remote server.

    MANAGEMENT

    ACE-3400 can be managed using different access methods, via:

    • A dedicated RS-232 or 10/100BaseT port

    • Dedicated VC defined on any ATM port

    • Gigabit Ethernet uplink port, using IP-based connection (raw IP or over PW).

    Software upgrades and configuration files can be downloaded/uploaded to/from ACE-3400 via TFTP or XMODEM.

    The following applications can be used for management:

    • Menu-driven terminal utility via an ASCII terminal connection

    • Telnet via an IP-based connection

    • Secure Shell (SSH) via any secure client/server application

    • ConfiguRAD, Web-based element management tool via an IP-based connection

    • RADview-EMS, RAD’s CORBA-based element management access system.

    The unit can be managed by and report to up to 16 different users simultaneously. Accounts of existing and new users can be defined/changed remotely, using a dedicated RADIUS server.

    ACE-3400 allows retrieval of the current date and time from a centralized location, by synchronizing with an SNTP (System Network Timing Protocol) server.

    ADVANCED SECURITY FEATURES

    ACE-3400 supports the Secure Socket Layer (SSL) protocol for enabling secure Web access to the unit. If enabled, the SSL protocol encrypts the data between the TCP and HTTP Web layers.

    Telnet-like management can be secured using a Secure Shell (SSH) client/server program. Instead of sending plain-text ASCII-based commands and login requests over the network, SSH provides a secure communication channel.

    In addition, ACE-3400 supports SNMP version 3, providing secure access to the device by authenticating and encrypting packets transmitted over the network.

    MODULAR ARCHITECTURE

    The modular architecture of ACE-3400 allows hot-swappable modules to be replaced in the field while maintaining uninterrupted service. The unit is fully accessible from the front panel.

    The unit's full hardware redundancy features (fans, power supplies, modules) ensure a fail-safe, continuous operation, making ACE-3400 ideal for carriers and service providers.

  • Data Sheet

    Specifications

    TRIBUTARY E1/T1 INTERFACE

    Number of Connectors 6

    Number of Interfaces Per Connector Up to 14

    Connector Type 64-pin Telco connector

    E1 INTERFACE

    Number of Ports 32 or 63

    Data Rate 2048 kbps

    Compliance G.703, G.704, G.732

    Jitter Performance Output and tolerance according to G.823 Transfer according to G.705

    Operation Mode ATM UNI, ATM IMA or TDM

    Line Code HDB3

    Framing MF, CRC-4 enabled MF, CRC-4 disabled Unframed

    LIU Support Short haul

    Monitoring Support Idle channel code insertion Alarm detection and insertion Errors statistics

    Line Impedance 120Ω, balanced 75Ω, unbalanced

    Connectors RJ-45, balanced BNC coaxial, unbalanced

    Note: E1 and T1 connectors are provided via a

    dedicated patch panel adapter, connected to two

    tributary connectors. For more information, refer to

    the Patch Panel Adapters data sheet.

    T1 INTERFACE

    Number of Ports 32 or 63

    Data Rate 1544 kbps

    Compliance ANSI T1.101, ITU-T G.703

    Jitter Performance According to AT&T PB-62411

    Operation Mode ATM UNI, ATM IMA or TDM

    Line Code B8ZS

    Line Mode DSU

    Framing ESF Unframed

    CRC-6 Calculation According to G.704

    Monitoring Support Idle channel code insertion Alarm detection and insertion Errors statistics

    Line Length Transmit gain up to 655 ft

    Line Impedance 100Ω

    Connectors RJ-45 (via a dedicated patch panel adapter; see previous note)

    STM-1/OC-3c/OC-3 INTERFACE

    Number of Ports Up to 4 (field-replaceable modules)

    Data Rate 155 Mbps

    Operation Mode SDH or SONET, ATM UNI, VC-12/VT1.5

    Compliance Physical layer and ATM mapping into STM-1/OC-3 according to I.432

    Automatic protection switching (APS) according to G.841 Annex B (1+1, bidirectional)

    Jitter Performance Output according to G.825 Tolerance according to G.823 Transfer according to G.783

    Fiber Optic Interface Type 1310 nm – multimode, single mode or single mode long haul

    Fiber Optic Connector SC

    GIGABIT ETHERNET INTERFACE

    Number of Ports Up to 2 (field-replaceable modules)

    Data Rate 1000 Mbps

    Compliance IEEE 802.3z, 802.1Q, 802.1p

    Max. Frame Size 1600 bytes

    Operation Mode Full-duplex

    Connector Small Form-Factor Pluggable (SFP),

    fiber optic RJ-45, electrical

    SFPs For full details, see the SFP Transceivers data sheet at www.rad.com

    Note: It is strongly recommended to order this

    device with original RAD SFPs installed. This will

    ensure that prior to shipping, RAD has performed

    comprehensive functional quality tests on the

    entire assembled unit, including the SFP devices.

    RAD cannot guarantee full compliance to product

    specifications for units using non-RAD SFPs.

    ETHERNET CONTROL PORT

    Type 100BaseTX, full-duplex

    Compliance IEEE 802.3

    Connector RJ-45

    http://www.rad.com/�

  • ACE-3400 Aggregation Site Gateway

    TERMINAL CONTROL PORT

    Type RS-232/V.24 (DCE)

    Data Rate 9.6, 19.2, 38.4, 57.6 or 115.2 kbps, user-configurable

    Connector RJ-45 (RJ-45 to DB-9 adapter cable is supplied)

    STATION CLOCK INTERFACE

    Type Balanced E1, unbalanced E1 (via an adapter cable) or T1

    Impedance Balanced E1: 120Ω Unbalanced E1: 75Ω (via an adapter cable) T1: 100Ω

    Connector RJ-45

    GENERAL

    Fan Tray Field-replaceable, four independent cooling fans

    Power One or two hot-swappable AC or DC: AC: 100 to 240 VAC, 47–63 Hz DC: -48 VDC nominal (-41 to -71 VDC)

    Note: AC and DC power supplies cannot be installed

    together in the same unit.

    Power Consumption 100W max

    LED Indicators POWER (green/red) – Green: power supply is OK Red: power supply failure SYS ALM (green/red) – Green: no system alarm is detected Red: at least one system alarm has been detected FAN (green/red) – Green: all the fans are working properly Red: at least one fan is not working properly RDY (green) – On: self-test completed successfully Blinking: self-test failed ACTIVE (green) – On: this main module is in Active mode Off: this main module is not in Active mode STANDBY (green) – On: this main module is in Standby mode Off: this main module is not in Standby mode ATM-155 SYNC 1–3 (green) – On: the port's physical link is synchronized Off: the port's physical link is not synchronized Blinking: RDI has been detected

    ATM-155 ATM 1–3 (green) – On: ATM cells are being received or transmitted Off: ATM cells are not being received or transmitted ETH 1/2 LINK (green) – On: Gigabit Ethernet link is detected Off: Gigabit Ethernet link is not detected ETH 1/2 ACT (green) – On: Frames are being received or transmitted Off: Frames are not being received or transmitted MNG-ETH LINK (green) – On: Ethernet link is detected Off: Ethernet link is not detected MNG-ETH ACT (yellow) – On: ETH frames are being received or transmitted Off: ETH frames are not being received or transmitted STATION CLK SYNC (green) – On: E1/T1 physical link is synchronized Off: E1/T1 physical link is not synchronized

    Physical Height: 13.3 cm (5.2 in / 3U) Width: 44.0 cm (17.3 in) Depth: 25.0 cm (9.0 in) Weight: 10.0 kg (22.0 lb)

    Environment Temperature: Operating: 0°–50°C (32°–122°F) Storage: -20°–70°C (-4°–158°F) Humidity: Up to 90%, non-condensing

    Figure 3. Classic 2G/3G Traffic Aggregation over ATM

  • Data Sheet

    * OOB = out-of-band

    ACE-3000 Product Family Comparison Table

    Features

    ACE-3600 ACE-3402 ACE-3400

    E1/T1 traffic aggregation

    STM-1/OC-3c traffic

    aggregation

    Channelized STM-1/OC-3 traffic

    aggregation

    E1/T1 ports 32 or 63 via patch panels

    ATM-155 ports Up to 8, 4 per module Up to 3, 1 per module Up to 3, 1 per module

    SFPs for ATM-155 ports

    Fast Ethernet ports 1 for OOB* management only 1 for OOB* management only 1 for OOB* management only

    Gigabit Ethernet ports Up to 2, 1 per module Up to 2, 1 per module Up to 2, 1 per module

    SFPs for GbE ports

    SFPs for FE ports

    PSN clock distribution

    APS on ATM-155 ports

    Ethernet redundancy

    System redundancy

    BSC/RNC-site gateway (RNC only) (BSC/RNC) (BSC/RNC)

    Max. ATM VCCs 1024 1024 1024

    Max. data PW links 1024 512 512

    Max. remote PSN peers 512 256 256

    Modular unit

    Power supply Single/dual, hot-swappable Single/dual, hot-swappable Single/dual, hot-swappable

    Physical width 17.3" 17.3" 17.3"

    Physical height 2U 2U 3U

  • 367-1

    00-1

    1/0

    8 Sp

    ecifications are su

    bject to

    chan

    ge with

    out p

    rior n

    otice. ©

    1998–2008 R

    AD

    Data Co

    mm

    unicatio

    ns Ltd

    . The R

    AD

    nam

    e, logo

    , logo

    type, an

    d th

    e terms Eth

    erAccess, TD

    MoIP an

    d TD

    MoIP D

    riven, an

    d th

    e pro

    duct n

    ames O

    ptim

    ux an

    d IPm

    ux, are registered

    tradem

    arks of R

    AD

    Data C

    om

    municatio

    ns Ltd

    . All o

    ther trad

    emarks are th

    e pro

    perty o

    f their resp

    ective hold

    ers.

    ACE-3400

    Aggregation Site Gateway

    Data Sheet

    International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel. 972-3-6458181 Fax 972-3-6498250, 6474436 E-mail [email protected]

    North America Headquarters 900 Corporate Drive Mahwah, NJ 07430, USA Tel. 201-5291100 Toll free 1-800-4447234 Fax 201-5295777 E-mail [email protected]

    www.rad.com Order this publication by Catalog No. 803651

    The Access Company

    Ordering ACE-3400/#

    Legend # Power supply type and redundancy: AC Single 100 to 240 VAC DC Single -48 VDC ACR Dual 100 to 240 VAC DCR Dual -48 VDC

    ACE-MC/*/~ ACE-3400 main module (main card)

    Legend * Main module type:

    155 STM-1/OC-3c to GbE 155-CH Channelized STM-1/OC-3 to

    ATM STM-1/OC-3c or GbE 32E1B 32 balanced E1s to ATM

    STM-1/OC-3c or GbE 32E1U 32 unbalanced E1s to ATM

    STM-1/OC-3c or GbE 32T1 32 T1s to ATM STM-1/OC-3c

    or GbE 63E1B 63 balanced E1s to ATM

    STM-1/OC-3c or GbE 63E1U 63 unbalanced E1s to ATM

    STM-1/OC-3c or GbE 63T1 63 T1s to ATM STM-1/OC-3c

    or GbE Note: The 155 option (STM-1/OC-3c to GbE)

    is available only with the PACK1 software

    license.

    ~ The required software license pack (Default= ATM network functionality):

    P1 ATM and PSN functionality, not including clock recovery over packet

    Note: For full system redundancy, order two main

    module units.

    ACE-IF-155/^/& SDH/SONET interface module

    Legend ^ Fiber type: 13L Single mode, 1310 nm 13LH Single mode, 1310 nm,

    long haul 13M Multimode, 1310 nm

    & Connector type: SC SC connector

    Note: For interface redundancy (APS), order two

    interface modules.

    ACE-IF-GbE/@ Gigabit Ethernet interface module

    Legend @ Port type: SFP SFP cage (empty) UTP 1000BaseT, electrical

    Note: For interface redundancy (APS), order two

    interface modules. The fiber optic

    Gigabit Ethernet ports require SFP transceivers

    that are fitted into the empty cage. For technical

    specifications and ordering information, refer to

    the SFP Transceivers data sheet, available on

    RAD's Web site.

    Note: It is strongly recommended to order the

    interface module with original RAD SFPs installed.

    This will ensure that prior to shipping, RAD has

    performed comprehensive functional quality tests

    on the entire assembled unit, including the SFP

    devices. RAD cannot guarantee full compliance to

    product specifications for ACE-3400 units using

    non-RAD SFPs.

    SUPPLIED ACCESSORIES

    AC power cord or a DC power connection kit (as ordered)

    RM-39 Hardware kit for mounting one ACE-3400 unit into a 19-inch rack

    CBL-RJ45/D9/F/STR Control port adapter cable (RJ-45 to DB-9)

    OPTIONAL ACCESSORIES

    ACE-PPANEL/BNC/21 Patch panel adapter with 21 unbalanced BNC connectors

    ACE-PPANEL/RJ45/28 Patch panel adapter with 28 balanced RJ-45 connectors

    Note: For more information about the supplied

    Patch Panel kit, refer to the Patch Panel Adapters

    data sheet, available on RAD's Web site.

    CBL-RJ45/2BNC/E1/X Adapter cable for converting a balanced E1 RJ-45 station clock connector to a pair of BNC connectors (if unbalanced E1 station clock source is used)

    ACE-PS/* ACE hot-swappable power supply unit (for replacement)

    * Power supply type: AC 100 to 240 VAC DC -48 VDC

    ACE-FTC/ACE-3400 Fan tray card (for replacement)

    ACE-MC-SW/! Software upgrade pack

    ! Software pack type: P1 PW over PSN functionality LDP LDP functionality