Data CenterQ23A in Skywalk between Bldgs 1 & 4QC … BUILDING 7 AG Arena. Data Center. E28A. E17A...
-
Upload
vuongnguyet -
Category
Documents
-
view
217 -
download
0
Transcript of Data CenterQ23A in Skywalk between Bldgs 1 & 4QC … BUILDING 7 AG Arena. Data Center. E28A. E17A...
...\AG PAVILLION ANNEX.dgn 1/11/2008 1:49:34 PM
DN
DN
DN
A201
A201
A201
2C
3C
6C
A701
NEW
EXIS
TIN
G
WOMENSB207
MENSB206
ITB214
OFFICEB220
BIOLOGYB219
PREPB212
CHEMISTRYB210
OFFICEB209
OFFICEB215
DISPLAY CASE
ELEC.B217
MICRO-BIOB216
COMMONB221A
22'-0
"67
'-6"
24'-0
"1'
-8 7
/8"
115'
-2 7
/8"
12'-0" 30'-9 1/8" 19'-11 3/4" 24'-6" 18'-3 1/8"
105'-6"
4'-0
"
A7033A
A7042A
A7053A
A7066A
A2015C
6AA202
6AA202
2AA202
2AA202
4AA202
4AA202
12'-0" 32'-6" 18'-6" 42'-6"
EXISTING GREENHOUSE
CHEM. STORAGEB211
BREAK OUT LABB208
9'-8 5/8" 8'-2 5/8"
7'-9 3/4"
10'-8
7/8
"8'
-4 7
/8"
5'-5
1/8
"6'
-11"
10'-5
7/8
"
10'-1
1 3/
4"53
'-11
1/2"
11'-6" 30'-6" 10'-2 1/8" 7'-8"
11'-6" 40'-8 1/8" 8'-3 1/8"
10'-1
0 1/
2"5'
-9 3
/8"
5'-2
3/4
"5'
-3 3
/8"
29'-11 1/4" 10'-2 1/8" 8'-3 7/8"
9'-0
"19
'-2 7
/8" +
/-
6"
13'-0
"37
'-0"
50'-0
"
EXISTING BUILDING
EXISTINGBUILDING B
JANITORB218
6CA501
6KA501
6BA502
A7013A
A701
4D
B208
6CA501
B215
B207 B206
B212D
B212C
B212B
B216
B220
B209
B221B
B221A
B210
B221C
B221D
B212A
B218
B219
6CA501
6CA501
6CA501
6JA502
W9
W9
W9
7'-0"
B217
6LA502
6MA501
6CA501
6CA501
6CA501
6JA502
6GA502
1 Ex1
Ex1
6
6
532
K
H
B
C
G
F
4
E
A.1
7
7
D
J
C.8
A
13'-0
"4'
-0"
12'-6
"4'
-0"
3'-6
"
4'-6" 7'-0" 2'-0" 7'-0" 2'-0" 7'-0" 3'-0" 18'-6"
A4033
A4034
A4035
A4036
A4037
A4038
A4032
A4039
A40310
A40310 TYP
A40310 TYP
A40310 TYP
A40310 TYP
A40311
A40311 TYP
A40311 TYP
A40311 TYP
A40312
A40312 TYP
A40311 TYP
A40311 TYP
A40314
A40311 TYP
A40313
A40310 TYP
A40315
A2015C
6F
A7016J
MECHB213
1'-7 5/8"
A7015A
4'-0" 14'-0" 24'-6"
B208G
B208D
B208E
B214
B215
B213
W3
W2B
W2B
W5
W3 W2
6B
20'-6
"7'
-0"
2'-0
"7'
-0"
2'-0
"7'
-0"
22'-0
"
W4R W4R W4R
W4
W4
W4
1'-7
"
W4 W4 W4
W1
4'-6" 7'-0" 2'-0" 7'-0" 2'-0" 8'-3 1/8" 8'-1 1/8" 2'-0"2'-0" 4'-0" 3'-10 5/8"
1'-7
1/8
"
7'-0
"
4'-3 1/8" 14'-0" 4'-11" 1'-3 7/8"
6'-0" 2'-0"1'-6"
7'-0" 2'-0"
39'-1
1 3/
4"30
'-6 1
/8"
40'-5
1/2
"
4'-0
"4'
-8 5
/8"
4'-0" 3'-4"
4'-7 3/4" 15'-10 1/2"4'-1 1/4"
L101 6A
6D
5J
W8
W8
W6TYP.
TYP
TYP
P3R
P3R
P6RP3
P3
P6a
P3R
P6a
P6R
P6R
P3R
P3
P3
P3
P6a
P3R
P3R
P3R
P3
P3
P3R
P6a
P3a
P3R
P3
P9R
P6R
P3R
P6a
P3R
L
L
L
L
1'-0
5/8
" 8'-0
"
B208CB208BB208A
M.B.
3'-9
3/8
"4'
-0"
APB APB
APBAPB
VESTIBULEB221B
VESTIBULEB221C
HALLWAYB221
GENERAL NOTES
A.
B.
C.
D.
E.
F.
TOP OF FIRST FLOOR SLAB = 100'-0" (786.00)UNLESS OTHERWISE NOTED.
THE LOCATION OF DIMENSION TICK MARKS AREAS FOLLOWS:DRYWALL PARTITION/FURRING:FACE OF STUD/FURRING.CONCRETE/MASONRY:FACE OF CONCRETE/ MASONRY.EXISTING WALL: FACE OF EXISTING FINISHSURFACEDIMENSIONS NOTED AS "CLEAR" OR "CLR.":DIMENSION IS TO FACE OF FINISH SURFACES.DIMENSIONS NOTED AS "FINISH" OR "FIN":DIMENSION IS TO FACE OF FINISH SURFACES.ITEMS NOTED AS "ALIGN":FINISH SURFACES SHALL BE IN THE SAME PLANE.
ALL DOOR FRAMES ARE TO BE SET 2" FROMCORNER OF STUD WALL OR 8" FROM CORNER OFMASONRY WALL UNLESS NOTED OTHERWISE.
ALL PARTITIONS ARE TO BE TYPE P3 UNLESSNOTED OTHERWISE.
ALL PARTITIONS SHALL EXTEND TO UNDERSIDEOF STRUCTURE (DECK OR BEAM) UNLESS NOTEDOTHERWISE. AT NON-FIRE RATED PARTITIONSINFILL VOIDS OF METAL DECK AT CONCEALEDLOCATIONS WITH BATT INSULATION; AT FIRE-RATED PARTITIONS USE FIRE-RESISTIVE JOINTSYSTEMS.
FOR MASONRY OPENINGS, REFER TO LINTELSCHEDULE ON STRUCTURAL SHEETS.
ABBREVIATIONS: AFF ABOVE FINISHED FLOOR CJ CONTROL JOINT CMU CONCRETE MASONRY UNIT EJ BRICK EXPANSION JOINT EWC ELECTRIC WATER COOLER FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET GB GYPSUM BOARD MB MARKER BOARD TB TACK BOARD APB ACTUATOR PUSH BUTTON AB ACTUATOR BOLLARD
BUILDING A
BUILDING B
BUIL
DIN
G C
SCIENCELAB ADDITION
LEGEND
ROOM NAME AND NUMBER -SEE SHEET A701 FOR ROOMFINISH SCHEDULE
A1011 SIM
101
P1
1A101
SIM
A201
1
A7011
1A101
SIM
DOOR NUMBER - SEE SHEETA401 FOR DOOR SCHEDULE
PARTITION TYPE - SEEPARTITION TYPE SCHEDULE
DETAIL REFERENCE:DETAIL NUMBER (TOP)SHEET NUMBER (BOTTOM)
BUILDING SECTION:DETAIL NUMBER (TOP)SHEET NUMBER (BOTTOM)
WALL SECTION:DETAIL NUMBER (TOP)SHEET NUMBER (BOTTOM)
BUILDING ELEVATION:DETAIL NUMBER (OUTSIDE)SHEET NUMBER (INSIDE)
INTERIOR ELEVATION:DETAIL NUMBER (OUTSIDE)SHEET NUMBER (INSIDE)
SPOT ELEVATION
ROOM NAME101
W1 WINDOW TYPE - SEE SHEET AXXX
? KEYED NOTE1
REMOVE STOREFRONTGLAZING SYSTEM ANDASSOCIATED STRUCTURE,TYP.
REMOVE CONCRETEFOUNDATION WALLAND CURB IN ITSENTIRETY, TYP.
REMOVE ROOF STRUCTURE INITS ENTIRETY. REMOVEFLASHING FROM FACE OFEXISTIN WALL TO REMAIN
REMOVE EXISTING FLOORING SYSTEM(INCLUDING ADHESIVES, FLOOR BASE,AND ANY OTHER INSTALLATIONMATERIALS) IN ITSENTIRETY
REMOVE MTL. SOFFIT PANELSAND ASSOCIATED SUPPORTS.
REMOVE CONCRETESLAB ON GRADE UP TOFACE OF EXIST.FOUNDTION WALL
REMOVE AUTOMATIC SLIDINGENTRANCE SYSTEMS.INCLUDES BUT NOT LIMITEDTO, SIDELIGHTS, SLIDINGPANELS, FRAMES TRANSOMS,AND THRESHOLDS. TURNOVER TO OWNER.
REMOVE MTL. STUD AND GYP.BULKHEAD IN ITS ENTIRETY.REMOVE PORTION OFEXIST. ACT CEILINGSYSTEM TO ALLOW FORTIE IN OF NEW WORK.
SEE C101 FOREXTENTS OFSITE DEMO
DEMOLITION GENERAL NOTES
A.
B.
C.
D.
E.
F.
G.
H.
FIELD VERIFY ALL CONDITIONS ANDDIMENSIONS.
THIS DRAWING AND ALL OTHER DEMOLITIONNOTES / PLANS IN THIS SET DO NOT LIMITTHE EXTENT OF THE REQUIRED DEMOLITIONWORK. CONTRACTOR IS RESPONSIBLE FORALL DEMOLITION WORK REQUIRED TOCOMPLETE WORK INDICATED.
REFER TOMECHANICAL/ELECTRICAL/PLUMBINGDRAWINGS FOR REMAINDER OF DEMOLITIONWORK.
ALL SURFACES DISTURBED OR EXPOSEDDURING DEMOLITION SHALL BE PATCHEDAND REPAIRED TO MATCH ADJACENTSURFACES.
CONTRACTOR IS RESPONSIBLE FORENSURING ANY ITEM THAT IS INDICATED TOBE SALVAGED FOR REUSE OR TURNED OVERTO THE OWNER, IS NOT DAMAGED DURINGREMOVAL OR RELOCATION.
ITEMS INDICATED TO REMAIN THAT AREINADVERTENTLY REMOVED OR DAMAGEDSHALL BE REPLACED AT THECONTRACTOR'S EXPENSE.
VERIFY WITH THE OWNER'SREPRESENTATIVE PRIOR TO DISPOSAL OFSALVAGEABLE DEMOLITION ITEMS.
VERIFY WITH ARCHITECT PRIOR TOMODIFICATION OR REMOVAL OF ANYSTRUCTURAL ELEMENTS, COLUMNS, BEAMS,LINTELS, BEARING WALLS, CUTTING OFFLOOR OPENINGS, ETC.
daterevised
drawn bychecked by
Design FirmRegistration
#184-000723
sheet
project
COPYRIGHT 2012 BY BLDD ARCHITECTS, INC.All rights reserved. No part of this document may be reproduced ortransmitted in any form or by any means, electronic or mechanical,including photocopying, recording, or by any information or storageretrieval system, without the written permission of the author, exceptwhere by permitted by law.
BLDD Architects, Inc.5183 Utica Ridge RoadDavenport, IA 52807Phone: 563-359-5777
1
2
3
4
5
6
B C D E HF G J K L MA
GAL
VA, I
L
7/5/2012 1:07:24 PM C:\Revit_TEMP\115UX26.400 BHC EC Lab Addition_jrh.rvt
115UX26.400
A101
LEVE
L TW
O D
EMO
PLA
N &
FLO
OR
PLA
N
EAST
CAM
PUS
SCIE
NC
E LA
B AD
DIT
ION
BID DOCUMENTS
07/02/12
JRHMRD
BLAC
K H
AWK
CO
LLEG
E
1/8" = 1'-0"6C LEVEL TWO FLOOR PLAN
0' 4' 8' 16' 32'
TRUE
PROJECT 1" = 80'-0"KEY PLAN
PARTITION TYPESP3 3 5/8" METAL STUDS @ 16" O.C. W/ ACOUST. BATT
INSULATION 5/8" GYP BOARD BOTH SIDESP3a 3 5/8" METAL STUD @ 16" O.C. W/ ACOUST. BATT INSULATION
5/8" GYP BOARD ONE SIDEP3R 3 5/8" METAL STUDS @ 16" O.C. W/ ACOUST. BATT
INSULATION 5/8" TYPE X GYP BOARD BOTH SIDES - FIRERATED 1 HR - UL DESIGN U419
P6a 6" METAL STUDS @ 16" O.C. W/ ACOUST. BATT INSULATION5/8" GYP BOARD BOTH SIDES
P6R 6" METAL STUDS @ 16" O.C. W/ ACOUST. BATT INSULATION5/8" TYPE X GYP BOARD BOTH SIDES - FIRE RATED 1HR - ULDESIGN - U419
P9R 5/8" TYPE X GYP BOARD, 3 5/8" METAL STUDS @ 16" O.C. W/ACOUST. BATT INSULATION, 1 7/8" AIR SPACE, 3 5/8" METALSTUDS @ 16" O.C. W/ ACOUST. BATT INSULATION, 5/8" TYP XGYP BOARD - FIRE RATED 1 HR - UL DESIGN U240
1" = 10'-0"6A DEMOLITION PLAN
0' 4' 8' 16' 32'
...\CAD\ARCH\10019512_F110.dgn 9/1/2006 8:38:17 AM