Daikin Air Conditioning Daikin air conditioners for shops, restaurants and offices. 4-WAY BLOW CEILING MOUNTED CASSETTE (600x600mm) UK Price List Attached Correct as of 13/04/08 Please check http://global-cooling.co.uk For the latest information
For more information about this range of air conditioning systems http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/daikin-airconditioning/ If you need any help please call us on 01200 428888 Or use Live Chat UK Price List Attached Please check the here for latest specifications and prices. Global Cooling Air Conditioning UK www.global-cooling.co.uk Upbrooks Industrial Estate Clitheroe, Lancashire BB7 1PL, UK UK Air Conditioning Online Shop - http://global-cooling.com/ Air Conditioning Forum - http://air-conditioning-forum.global-cooling.co.uk/
Daik in a i r condi t ioners
for shops , res taurants and off i ces
4-WAY BLOW CE I L ING MOUNTE D CASSET TE ( 600x600mm)
FFQ-B7
ww
w.d
aik
ine
uro
pe
.co
m
EPLE05-27A_OPI 2/09/05 9:07 Page 1
MOV91822_EPLE05-27A
Cyan Magenta Yellow Black
Wired remotecontrol (Optional)
Ceiling voidis 295mm
Standard setting: Auto swing between 0° to 60°
Ceiling voidis 295mm
Draught prevention:Auto swing between 0° and 35°
Ceiling soiling prevention:Auto swing between 25° and 60°
Ceiling voidis 295mm
0°
60°
0°
35°
25°
60°
COMFORT
• You have the choice of 2 fan speeds to select: high or low. A high fan speed providesmaximum reach while a low fan speed minimizes drafts.
• The indoor unit is extremely quiet in operation. The sound levels are as low as 24.5dB (A),comparable to rustling leaves.
• Daikin’s special dry programme reduces humidity in the room without variations inroom temperature.
• The indoor unit contains an air filter which removes microscopic particles and dust.
• You have the choice of 3 auto-swing positions for maximum comfort: standard, draughtprevention or ceiling soiling prevention. Since the flaps can move to a 0° position, youwill experience virtually no draught!
The ceiling mounted 4-way blow cassette is specially designed for use in false ceilings.The greater part of the unit integrates perfectly with 600x600mm ceiling tiles. Onlythe slim decoration panel remains visible. As their name suggests, these units candischarge air in any of 4 directions.These cassettes are equipped with a special draught prevention and anti-ceilingsoiling technology.
EPLE05-27A_OPI 2/09/05 9:07 Page 2
MOV91822_EPLE05-27A
Cyan Magenta Yellow Black
Wired remotecontrol (Optional)
Infrared remotecontrol (Optional)
• The indoor unit can easily be installed into false ceilings (minimum height of 295mm).
• Due to the compact casing, it matches standard architectural modules of 600 x 600mm- ceiling tile cutting is no longer necessary.
• When the ceiling void is too small, a panel spacer can be used to cover the spacebetween the ceiling and decoration panel.
• It is possible to shut one or 2 flaps off enabling the unit to be installed in the middleof the room, in a corner or in a small room.
FLEXIBLE INSTALLATION AND EASY TO USE AND MAINTAIN
• Since the switch box is located within the unit, it is easy to access from below formaintenance without removing ceiling tiles.
• The outdoor unit can be installed on a roof or terrace or placed against an outside wall.
• Special anti-corrosion treatment of the outdoor unit’s heat exchanger fin, givesgreater resistance against acid rain and salt corrosion. Additional resistance is providedby a rustproof steel sheet on the underside of the unit.
• Daikin remote controls give you easy control at your fingertips.
• The wired remote control provides you with a schedule timer, enabling the airconditioning to be programmed daily or weekly.
• The optional remote ON/OFF enables you to start/stop the air conditioning from amobile phone via a telephone remote control (field supply). The optional forced OFF enables you switch off the unit automatically. E.g. when awindow is opened, the unit switches off.
Heat exchanger
An anti-corrosion heatexchanger cutaway view
Aluminium
Hydrophilic film
Corrosion-resistantAcrylic resin
2-Way blow 3-Way blow 4-Way blow
EPLE05-27A_OPI 2/09/05 9:07 Page 3
MOV91822_EPLE05-27A
Cyan Magenta Yellow Black
ENERGY EFFICIENT
• This model can be used for cooling only or heating.
• It is possible to use the indoor unit in pair (connecting one indoor to one outdoor), twin,triple, double twin (connecting up to 4 indoors in the same room to a single outdoor)and multi applications (connecting up to 9 units in several rooms to 1 outdoor unit).
APPLICATION OPTIONS
When you go out pushthe “Home leaveoperation” button, andthe air conditioner willadjust capacity to reachthe preset temperaturefor “Home leaveoperation”.
When you return, youwill be welcomed bya comfortableair-conditioned room.
Push the “Home leaveoperation” button again,and the air conditionerwill adjust capacity tothe set temperature fornormal operation.
While out of the home
Inverter air conditioning
Non inverterair conditioning
Set point
Large temperaturedifference
Repeats hot and cold cycles
Keeps temperature stable
Startup time reducedby about 1/3
Slow start-up
Improved comfort:The rapid start up time provided by the inverter increases comfort by reducing the leadtime in obtaining the required indoor temperature. As soon as the required temperatureis reached, the inverter unit continuously scans the room for small changes and adjuststhe room temperature in seconds, thereby increasing comfort once again.
• The ‘home leave’ operation button prevents large temperature differences bycontinuously operating at a minimum (heating mode) or maximum (cooling mode) presetlevel while you’re out or sleeping. It also allows the indoor temperature to return quicklyto your favourite comfort level.
Smallertemperaturedifference
ONE PUSH PUSH AGAIN
• Energy label: up to class B
• Inverter technologyImproved energy efficiency:The use of integrated inverter control ensures maximum energy efficiency by supplyingonly the required heating or cooling load where a standard non inverter unit would supplymaximum load in an on/off regime.
EPLE05-27A_OPI 2/09/05 9:07 Page 4
MOV91822_EPLE05-27A
Cyan Magenta Yellow Black
Notes:1) Energy label : scale from A (most efficient) to G (less efficient).2) Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions)
Capacity and power input
Notes: - For more detailed information about specifications, capacities, power input, energy labelling and annual energy consumption, please refer to our Multi Model Catalogue/Super Multi Plus Catalogue or checkwith your local dealer.* At least 2 indoor units should be connected to a Multi outdoor unit.
MULTI - COOLING ONLY
4MKS58D4MKS75D4MKS90DMULTI - HEAT PUMP
2MXS52D*3MXS52D*4MXS68D*4MXS80D*SUPER MULTI PLUS - HEAT PUMP
RMXS112D*RMXS140D*RMXS160D*
Max. n° Max. cooling Max. PI coolingof indoor units capacities (kW) (kW)
4 6.60 2.474 9.27 3.714 9.86 3.52
Max. n° Max. cooling Max. PI cooling Max. heating Max. PI heatingof indoor units capacities (kW) (kW) capacities (kW) (kW)
2 6.50 2.69 7.34 2.423 6.50 2.69 7.34 2.424 8.68 3.69 10.64 3.414 9.49 3.34 11.00 3.52
Max. n° Max. cooling Max. PI cooling Max. heating Max. PI heatingof indoor units capacities (kW) (kW) capacities (kW) (kW)
7 11.20 3.57 12.50 4.018 14.00 5.23 16.00 5.319 15.50 5.55 17.50 5.56
TWIN/TRIPLE/DOUBLE TWIN APPLICATION
RR/RQ71RR/RQ100RR/RQ125RZQ71RZQ100RZQ125RZQ140RZQ200RZQ250
FFQ35B7V1B FFQ50B7V1B FFQ60B7V1B
23 2
3 223 24 3 24 3
4 34
COOLING ONLY - INVERTER CONTROLLED/NON INVERTER(air cooled)
Cooling capacity min~nom~max kWNominal input min~nom~max kWEEREnergy labelAnnual energy consumption cooling kWhHEAT PUMP - INVERTER CONTROLLED(air cooled)
Cooling capacity min~nom~max kWHeating capacity min~nom~max kWNominal input cooling min~nom~max kW
heating min~nom~max kWEERCOPEnergy label cooling
heatingAnnual energy consumption cooling kWh
FFQ25B7V1B FFQ35B7V1B FFQ50B7V1B FFQ60B7V1B FFQ50B7V1B FFQ60B7V1BRKS25DVMB RKS35DVMB RKS50BVMB9 RKS60BVMB9 RS50BVMB RS60BVMB
1.3~2.5~3.0 1.4~3.4~3.7 0.90~4.70~5.60 0.90~5.80~6.00 4.70 (nom) 5.80 (nom)0.30~0.83~1.10 0.30~1.30~1.47 0.45~1.80~2.26 0.45~2.07~2.15 1.80 (nom) 2.07 (nom)
3.01 2.62 2.61 2.80 2.61 2.80B D D D D D
415 650 900 1,035 900 1,035FFQ25B7V1B FFQ35B7V1B FFQ50B7V1B FFQ60B7V1BRXS25DVMB RXS35DVMB RXS50BVMB RXS60BVMB
1.3~2.5~3.0 1.4~3.4~3.7 0.90~4.70~5.60 0.90~5.80~6.001.3~3.2~4.5 1.4~4.5~5.0 0.90~5.50~7.00 0.90~7.00~8.00
0.30~0.83~1.10 0.30~1.30~1.47 0.45~1.80~2.26 0.45~2.07~2.150.29~0.935~1.75 0.29~1.60~1.80 0.45~1.96~2.78 0.45~2.49~2.92
3.01 2.62 2.61 2.803.42 2.81 2.81 2.81
B D D DB D D D
415 650 900 1,035
EPLE05-27A_OPI 2/09/05 9:07 Page 5
MOV91822_EPLE05-27A
Cyan Magenta Yellow Black
FFQ25B7V1B FFQ35B7V1B FFQ50B7V1B FFQ60B7V1B
286x575x57555x700x700
17.52.7
White (RAL9010)9/6.5 10/6.5 12/8 15/10
2 steps29.5/24.5 32/25 36/27 41/32
46.5 49 53 58ø6.4
ø9.5 ø12.7ø20ø26
Both liquid and gas pipes
COOLING ONLY/HEAT PUMP
Dimensions HxWxD unit mmdecoration panel mm
Weight unit kgdecoration panel kg
Colour decoration panelAir flow rate H/L m3/minFan speedSound pressure level H/L dB(A)Sound power level H dB(A)Piping connections liquid mm
gas mmdrain (VP25) ID mm
OD mmHeat insulation
Specifications indoor units
FFQ25,35,50,60B7V1B
Indoor unit: FFQ-B
EPLE05-27A_OPI 2/09/05 9:07 Page 6
MOV91822_EPLE05-27A
Cyan Magenta Yellow Black
COOLING ONLY
Dimensions HxWxD mmWeight kgCasing colourSound pressure level H/L dB(A)Sound power level H dB(A)CompressorRefrigerant typeRefrigerant charge kg/mMaximum piping length mMaximum level difference mOperation range from ~ to °CDBHEAT PUMP
Dimensions HxWxD mmWeight kgCasing colourSound pressure level cooling H/L dB(A)
heating H/L dB(A)Sound power level cooling H dB(A)
heating H dB(A)CompressorRefrigerant typeRefrigerant charge kg/mMaximum piping length mMaximum level difference mOperation range cooling from ~ to °CDB
heating from ~ to °CWB
RKS25DVMB RKS35DVMB RKS50BVMB9 RKS60BVMB9 RS50BVMB RS60BVMB
550x765x285 735x825x300 735x825x30030 32 49 53 49 53
Ivory white Ivory white46/43 47/44 47/- 49/- 47/- 49/-
61 62 63 64 63 64hermetically sealed swing type Swing compressor
R-410A R-410A0.02 (for piping length exceeding 10m) 0.02 (piping length>10m)
20 30 3015 20 20
-10~46 -10(-15*)~46 +10~46RXS25DVMB RXS35DVMB RXS50BVMB RXS60BVMB
550x765x285 735x825x30030 32 49 53
Ivory white46/43 47/44 47/- 49/-47/44 48/45 48/- 49/-
61 62 63 6462 63 64 64
hermetically sealed swing typeR-410A
0.02 (for piping length exceeding 10m)20 3015 20
-10~46-15~20
Specifications outdoor units
* Possibility to extend the operation range down to -15°C by turning ON the switch on the outdoor unit PCB. In this case, the unit will stop operation at -20°C or lower and will recover when temperature rises again.- Information is not available.
FFQ25,35,50,60B7V1B
EPLE05-27A_OPI 2/09/05 9:07 Page 7
MOV91822_EPLE05-27A
Cyan Magenta Yellow Black
INDOOR UNITS FFQ25B FFQ35B FFQ50B FFQ60B
Wired remote control BRC1D528Infrared remote control cooling only BRC7EA531W7
heat pump BRC7EA530W7Centralised remote control DCS302CA51Unified ON/OFF control DCS301BA51Schedule timer DST301BA51Adapter for wiring (1) KRP1BA57Adapter for external ON/OFF and monitoring (1) KRP4AA53Adapter for wiring (hour meter) (2) EKRP1B2ARemote sensor KRCS01-1AInstallation box for adapter PCB KRP1BA101Interface adapter for Sky Air DTA112BA51Remote ON/OFF, forced OFF EKROROA
(1) Installation box for adapter PCB (KRP1B101) is necessary.(2) Possibility to connect an hour meter (field supply). This part should not be installed inside the equipment.
Accessories: control systems
INDOOR UNITS FFQ25B FFQ35B FFQ50B FFQ60B
Decoration panel BYFQ60BAW1long-life filter KAFQ441BA60Fresh air intake kit direct installation type KDDQ44XA60Sealing member of air discharge outlet KDBHQ44BA60Panel spacer KDBQ44BA60
Accessories
RKS/RXS25D RKS/RXS35D RS/RKS/RXS50B RS/RKS/RXS60B
KRW937A4 KPW945AA4KKP937AA4 - -
Accessories
Notes:1) V1 = 1~,230V,50Hz; VM = 1~, 220-240V/220-230V, 50Hz/60Hz; V3 = 1~, 230V, 50Hz2) Nominal cooling capacities are based on: indoor temperature 27°CDB/19°CWB • outdoor temperature 35°CDB • refrigerant piping length 7.5m • level difference 0m.3) Nominal heating capacities are based on: indoor temperature 20°CDB • outdoor temperature 7°CDB/6°CWB • refrigerant piping length 7.5m • level difference 0m.4) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.5) Units should be selected on nominal capacity. Max. capacity is limited to peak periods.6) The sound pressure level is measured at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment. 7) The sound power level is an absolute value indicating the "power" which a sound source generates.
OUTDOOR UNITS
Air direction adjustment grilleCentral drain plug
EPLE
05-2
7A /
CD /
09/0
5 / L
a M
ovid
a
Daikin products are distributed by:
Zandvoordestraat 300
B-8400 Oostende, Belgium
www.daikineurope.com
Daikin’s unique position as a manufacturerof air conditioning equipment, compressorsand refrigerants has led to its closeinvolvement in environmental issues. Forseveral years Daikin has had the intention tobecome a leader in the provision ofenvironmental friendly products. Thischallenge demands the eco design anddevelopment of a wide range of productsand an energy management system; whichinvolves energy conservation and reductionof waste.
“The present leaflet is drawn up by way of information only anddoes not constitute an offer binding upon Daikin Europe N.V..Daikin Europe N.V. has compiled the content of this leaflet tothe best of its knowledge. No express or implied warranty isgiven for the completeness, accuracy, reliability or fitness forparticular purpose of its content and the products and servicespresented therein. Specifications are subject to change withoutprior notice. Daikin Europe N.V. explicitly rejects any liability forany direct or indirect damage, in the broadest sense, arisingfrom or related to the use and/or interpretation of this leaflet.All content is copyrighted by Daikin Europe N.V..”
Daikin Europe N.V. is approved by LRQA for itsQuality Management System in accordance withthe ISO9001 standard.ISO9001 pertains to quality assurance regardingdesign, development, manufacturing as well as toservices related to the product.
ISO14001 assures an effective environmentalmanagement system in order to help protect humanhealth and the environment from the potentialimpact of our activities, products and services andto assist in maintaining and improving the qualityof the environment.
Daikin units comply with the European regulationsthat guarantee the safety of the product.
Daikin Europe NV participates in the EuroventCertification Programme for Air Conditioners (AC),Liquid Chilling Packages (LCP) and Fan Coil Units(FC); the certified data of certified models are listedin the Eurovent Directory. Multi units are Euroventcertified for combinations up to 2 indoor units.
EPLE05-27A_OPI 2/09/05 9:07 Page 8
MOV91822_EPLE05-27A
Cyan Magenta Yellow Black
Global Cooling Air Conditioning UK Prices*
Daikin 600mm x 600mm Cassette Type Air Conditioning – COOLING ONLY TYPES
Features Nom cooling Nom heating UK Cool
UK Cool
UK Heat - - Inter wires - - Max pipe - - - - Price
Daikin Inverter Models Cooling Only Types Min~norm~max Min~norm~max T/C kw
S/C kw kw Run
amps Fuse connecting Liquid Suction separation Max level
min amb
kg in kg out Exc Vat
FFQ25B+RKS25F Buy it online 1.3~2.4~3.0 n/a 2.5 1.9 n/a 3.8 15 3+e 1/4" 3/8" 25 15 -10 12 37 £957.68
FFQ35B+RKS35F Buy it online 1.4~3.4~3.8 n/a 3.4 2.3 n/a 5.5 15 3+e 1/4" 3/8" 25 15 -10 12 37 £1087.63
FFQ50B+RKS50F Buy it online 1.7~4.7~5.6 n/a 5.0 3.5 n/a 7.3 20 3+e 1/4" 1/2" 30 20 -10 12 49 £1272.18
FFQ60B+RKS60F Buy it online 1.7~5.8~6.0 n/a 5.8 4.2 n/a 9.3 20 3+e 1/4" 1/2" 30 20 -10 12 53 £1368.27
*Please check the following page for latest specifications and prices for this range of air conditioning systems.
http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/daikin-airconditioning/
Please see the next page for heat pump type prices.
Global Cooling Air Conditioning UK Prices*
Daikin 600mm x 600mm Cassette Type Air Conditioning – HEAT PUMP TYPES
Features Nom cooling Nom heating UK Cool
UK Cool
UK Heat - - Inter wires - - Max pipe - - - - Price
Daikin Inverter Models Heat Pump Types Min~norm~max Min~norm~max T/C kw
S/C kw kw Run
amps Fuse connecting Liquid Suction Separation Max level
min amb
kg in kg out Exc Vat
FFQ25B+RXS25F Buy it online 1.3~2.5~3.0 1.3~3.2~4.5 2.5 1.9 2.5 3.8 15 3+e 1/4" 3/8" 25 15 -10 12 37 £1016.65
FFQ35B+RXS35F Buy it online 1.4~3.4~3.7 1.4~4.0~5.0 3.4 2.3 3.0 5.5 15 3+e 1/4" 3/8" 25 15 -10 12 37 £1153.15
FFQ50B+RXS50G Buy it online 1.7~4.7~5.6 1.7~5.5~7.0 4.7 3.5 4.0 7.3 20 3+e 1/4" 1/2" 30 20 -10 12 49 £1367.18
FFQ60B+RXS60F Buy it online 1.7~5.8~6.0 1.7~7.0~8.0 5.8 4.2 5.1 9.3 20 3+e 1/4" 1/2" 30 20 -10 12 53 £1463.28
*Please check the following page for latest specifications and prices for this range of air conditioning systems.
http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/daikin-airconditioning/
If you need any help please call us on 01200 428888 or use Live Chat