Cylinder - files.ctctcdn.comfiles.ctctcdn.com/ee371090101/69d56f33-adf8-409e-8... · $ &˙ ˚ˇ "˙...
Transcript of Cylinder - files.ctctcdn.comfiles.ctctcdn.com/ee371090101/69d56f33-adf8-409e-8... · $ &˙ ˚ˇ "˙...
Page 2
GEC Dispenser Specification Design FormCOMPLETE ALL 4 STEPS!!
STEP 1: Pick Your Cabinet Style Blackmer (LGF1P) Corken (C12)
No Cabinet - Pump/Meter Assy DU1 (pg 3)…...….................… DU12 (pg 3)……..................….
Cabinet - Small
• Aluminum (Single Door).. DCS50DP.B1 (pg 3)...........…. DCS50DP.C12 (pg 3)...........…
• Aluminum (Double Door). DCS48DP.B1 (pg 3)...........…. DCS48DP.C12 (pg 3)...........…
• Galvanized………………. DCS59GAL.B1 (pg 4)……..... DCS59GAL.C12 (pg 4).....…...
• White Enamel…………… DCS46PT.B1…..........……..... DCS46PT.C12 (pg 4).....…......
Cabinet - Large
• Aluminum……………….. DCL51DP.B1 (pg 5).....…...... DCL51DP.C12 (pg 5)..............
• Stainless Steel………….. DCL51SS.B1 (pg 6)...…....... DCL51SS.C12 (pg 6)..............
• White Enamel…………… DCL49PT.B1......................... DCL49PT.C12 (pg 6).…..........
Cabinet - Large Walk-In
• Aluminum………….. DCWI75DP.B1 (pg 7)…........ DCWI75DP.C12 (pg 7)............
NOTE: All dispenser cabinets include pre-plumbed assembly connecting pump, 1” Neptune meter, Veeder-Root display only
register on base with all valves and an explosion-proof on/off switch assembly. Standard configuration has outlet for cylinder
filling before the meter and motor fueling outlet after the meter (no CFH/MFH hoses included) with pullaway valve & hose.
(Customer to provide piping for pump bypass & meter vapor return.)
STEP 2: Pick Your Hoses Hose Assemblies - Page 12
MFH Standard - Motor fuel hose (¾” x 18’ Parker hose with A7793A low loss valve/nozzle).............................................
MFH Economy - Motor fuel hose (¾” x 18’ Parker hose with 7554LV valve/A7575L3 coupling)........................................
MFH Gasguard - Motor fuel hose (¾” x 18’ Parker hose with Gasguard GG20 safety nozzle) ..........................................
CFH Standard - Cylinder hose (½” x 6’ Parker hose/RegO 7901TB quick-acting valve & 7193D-10 POL connection) .....
CFH Long - Cylinder hose (½” x 10’ Parker hose/RegO 7901TB quick-acting valve & 7193D-10 POL connection) ..........
DU-3Way - Optional 3-Way valve & components for CFH & MFH to be configured downstream of meter with 3-way valve .....
STEP 3: Pick Your Piping Kit Installation Piping Kits - Page 13
T2P-1 - Tank to Pump piping kit for 1” inlet pump (Blackmer LGF1P) .................................................................................
T2P-114 - Tank to Pump piping kit for 1 1⁄4” inlet pump (Corken C10 & Blackmer LGLF1 1⁄4” & LGL1 1⁄4”) .............................
T2P-112 - Tank to Pump piping kit for 1 1⁄2” inlet pump (Corken C12) ..................................................................................
STEP 4: Select Your Options Options - Page 14
TL36 - Tank Leg Stands (pair) with bolts for use with 500 & 1000 WG tanks only (32.5" centerline width) ........................
1124 - Fairbanks Beam Scale (1,000 lb capacity) ...............................................................................................................
400051-ECOUNTLT - Itron 1” standard meter w/air eliminator, strainer, differential valve & Mid-Com E-Count LT register...ECK - Electrical conduit kit is pre-installed rigid conduit, junction boxes, seal-offs & union (NOTE: Electrician to supply
properly sized wire & install sealant in seal-off fitting.)..............................................................................................
DUPK - Pre-installed cylinder vapor purging system mounted to interior of cabinet ...........................................................
CK - Cable kit components to provide cable operation of 1 1⁄4” internal valve from inside cabinet. Specify SM or LG.........
DURESS Kit - Components to provide externally mounted remote cable & thermal closure of A3209 internal valve ........
PK - Pneumatic Kit components to provide remote pneumatic operation and thermal protection of internal valves...........
Page 3
DCS48DP.C12 - Closed DCS48DP.B1 (Shown with option: MFH & CFH installed)
DU1 with 929980 switch DU12
CABINETS - SMALL
(Actual Product May Vary From Photos)
MOTOR FUEL DISPENSING UNITS (Actual Product May Vary From Photos)
No Cabinet - Pump/Meter Assembly
Dimensions
• 48”H x 36”W x 20”D
DCS50DP.B1 - ClosedDCS50DP.C12 (Shown with option: MFH Economy installed)
Dimensions
• 50”H x 40”W x 20”D
Page 4
CABINETS - SMALL (con’t.) (Actual Product May Vary From Photos)
White Enamel - Closed
DCS46PT.C12 (Shown with options: MFH Economy & CFH installed)
Dimensions
• 46”H x 40”W x 18”D
Galvanized - Closed
Dimensions
• 59”H x 36”W x 20”D
DCS59GAL.C12
Page 5
CABINETS - LARGE (Actual Product May Vary From Photos)
Diamond Plate - Closed
DCL51DP.B1 (Shown with options: MFH Standard & CFH installed)
DCL51DP.C12 (Shown with options: MFH Standard & CFH installed)
Dimensions
• 51”H x 47 1⁄2”W x 39 1⁄2”D
Page 6
DCL51SS.B1 (Shown with options: MFH Standard & CFH installed)
Stainless Steel - Closed
DCL51SS.C12 (Shown with options: MFH Standard & CFH installed)
White Enamel - Closed
DCL49PT.C12 (Shown with options: MFH Economy & CFH installed)
CABINETS - LARGE (con’t.) (Actual Product May Vary From Photos)
Dimensions
• 51”H x 47 1⁄2”W x 39 1⁄2”D
Dimensions
• 49”H x 44”W x 38”D
Page 7
CABINETS - WALK-IN (Actual Product May Vary From Photos)
Diamond Plate Walk-In - Closed
DCWI75DP.B1 (Shown with options: MFH Standard, CFH &1124-Scale installed)
Dimensions
• 75”H x 48”W x 54”D
Storage shelving - The GEC walk-in cabinet features two
exclusive shelves for tickets, gloves, tools, & adapters on
either side of the meter.
DCWI75DP.C12 Same as above but with a Corken pump installed instead of
Blackmer pump.
Page 8
AUTOGAS IN 4 STEPS!!GEC Dispenser Sheet - MARKETERSAddendum to GEC Dispenser Design Form - AUTOGAS
STEP 1: Pick Your Cabinet Style Blackmer 5HP Motor Corken 7.5HP Motor
LGL156A DLF075
No Cabinet - Pump/Meter Assy MFDU.HD.LGL156.3PH (pg 9)..… MFDU.HD.DLF075.3PH (pg 9)….
MFDU.HD.LGL156.1PH (pg 9)..… MFDU.HD.DLF075.1PH (pg 9)….
Cabinet - Small Aluminum Diamond Plate (pump on slide base) Page 9
• 3 Phase motor DCS50DP.LGL156.3PH ...... DCS50DP.DLF075.3PH .….
• 1 Phase motor DCS50DP.LGL156.1PH .… DCS50DP.DLF075.1PH .....
Cabinet - Small Galvanized (pump on slide base) Page 10
• 3 Phase motor DCS59GAL.LGL156.3PH ... DCS59GAL.DLF075.3PH ...
• 1 Phase motor DCS59GAL.LGL156.1PH ... DCS59GAL.DLF075.1PH ...
Cabinet - Large Aluminum Diamond Plate (will hold scales/pump inside) Page 10
• 3 Phase motor DCL51DP.LGL156.3PH … DCL51DP.DLF075.3PH ...
• 1 Phase motor DCL51DP.LGL156.1PH … DCL51DP.DLF075.1PH ...
NOTE: All dispensers include pre-plumbed assembly connecting HDP pump/motor, 1” Neptune meter, Veeder-Root display
only register on meter base with all valves, mounting flanges and an explosion-proof on/off switch assembly. Standard config-
uration has outlet for autogas fueling outlet (MFH) after the meter with a pullaway valve. Small cabinets include slide base
with pump/motor mounted externally and square piping connecting slide base to cabinet.
STEP 2: Pick Your Hoses Hose Assemblies - Page 12
MFH Standard - Motor fuel hose (¾” x 18’ Parker hose with A7793A low loss valve/nozzle).............................................
MFH Economy - Motor fuel hose (¾” x 18’ Parker hose with 7554LV valve/A7575L3 coupling)........................................
MFH Gasguard - Motor fuel hose (¾” x 18’ Parker hose with Gasguard GG20 safety nozzle) .........................................
CFH Standard - Cylinder hose (½” x 6’ Parker hose with RegO 7901TB quick-acting valve & 7193D-10 POL connection) ...
CFH Long - Cylinder hose (½” x 10’ Parker hose/RegO 7901TB quick-acting valve & 7193D-10 POL connection) ..........
DU-3Way - Optional 3-Way valve & components for CFH & MFH to be configured downstream of meter with 3-way valve .....
STEP 3: Pick Your Piping Kit Installation Piping Kits - Page 13
T2P-114x112 - Tank to Pump piping kit for DLF075 pump (1-1/2" flange) (1-1/2" piping, valves, flex, strainer) .................
T2P-114x200 - Tank to Pump piping kit for LGL156 pump (2" flange) (2" piping, valves, flex, strainer)..............................
STEP 4: Select Your Options Options - Pages 11 & 14
TL36 - Tank Leg Stands (pair) with bolts for use with 500 & 1000 WG tanks only (32.5" centerline width) ........................
1124 - Fairbanks Beam Scale (1,000 lb capacity) ...............................................................................................................
400051-ECOUNTLT - Itron 1” standard meter w/air eliminator, strainer, differential valve & Mid-Com E-Count LT register...
FST-634 - Blue Moon Filter assembly..................................................................................................................................
MA-4-CX-10 - Liquid Controls standard meter w/air eliminator, strainer, differential valve and counter..............................
ECK - Electrical Conduit Kit is pre-installed rigid conduit, junction boxes, seal-offs & union (NOTE: Electrician to supply
properly sized wire & install sealant in seal-off fitting.) Specify SM or LG.................................................................
CTK40-24-36-ES - Single-phase magnetic starter package includes non-classified enclosure, magnetic starter, terminal
blocks, designed for use with motors with crankcase heaters & thermostats; designed for installation
outside of classified electrical locations & includes an ESO (emergency shut-off) .............................
Page 9
CTK40-24-36-ES-3P - Three-phase magnetic starter package includes non-classified enclosure, magnetic starter, terminal
blocks, designed for use with motors with crankcase heaters & thermostats; designed for installation
outside of classified electrical locations & includes an ESO (emergency shut-off) .......................
Gasguard Holster - Locking capable holster for Gasguard nozzles - can be mounted to exterior/interior of cabinet ........
DUPK - Pre-installed cylinder vapor purging system mounted to interior of cabinet ...........................................................
CK - Cable Kit components to provide cable operation of 1 1⁄4” internal valve from inside cabinet. Specify SM or LG ........
DURESS Kit - Components to provide externally mounted remote cable & thermal closure of internal valve ...................
PK - Pneumatic Kit components to provide remote pneumatic operation and thermal protection of internal valves...........
DUST - Dispensing unit square tubing (sold by the foot), use two 4 foot sections to connect slide base to cabinet...........
RETROFIT Solutions: Add a HDP Pump on Slide Base to existing Dispensers Page 10
SBU.HD.LGL156.3PH - Includes Blackmer LGL156 HDP pump, 5HP, 3PH, EXP motor, by-pass, slide base, companion
flanges, gaskets, studs/nuts, pressure gauges, plus fitting pkg....................................................SBU.HD.LGL156.1PH - Includes Blackmer LGL156 HDP pump, 5HP, 1PH, EXP motor, by-pass, slide base, companion
flanges, gaskets, studs/nuts, pressure gauges, plus fitting pkg....................................................SBU.HD.DLF075.3PH - Includes Corken DLF075 HDP pump, 7.5HP, 3PH, EXP motor, by-pass, slide base, companion
flanges, gaskets, studs/nuts, pressure gauges, plus fitting pkg....................................................SBU.HD.DLF075.1PH - Includes Corken DLF075 HDP pump, 7.5HP, 3PH, EXP motor, VFD (variable frequency drive for
1 phase application, by-pass, slide base, companion flanges, gaskets, studs/nuts, pressure
gauges, plus fitting pkg .................................................................................................................
DCS50DP.DLF075.3PH (Shown with MFH-Standard)
AUTOGAS CABINETS - SMALL (Actual Product May Vary From Photos)
Cabinet Dimensions
• 50”H x 40”W x 20”D
• SBU.HD unit: 27 ½”H x 36”W x 19”D
MFDU.HD.DLF075.3PH
Dimensions
• 39”H x 34”W x 21 1⁄2”D
Page 10
AUTOGAS CABINETS - SMALL (con’t.) (Actual Product May Vary From Photos)
DCS59GAL.LGL156.3PH (Shown with options: 1) Blue Moon Filter, 2) MFH GasGuard,3) GasGuard Holster, 4) Custom Vinyl Wrap)
AUTOGAS CABINETS - LARGE (Actual Product May Vary From Photos)
DCL51DP.LGL156.1PH (Shown with MFH-Standard, CHF-standard & DUPK)
Dimensions
• 51”H x 47 1⁄2”W x 39 1⁄2”D
Dimensions
• 59”H x 36”W x 20”D
SBU.HD.DLF075.3PH
Dimensions
DUSB base: 3 ½ ”H x 36”W x 16”D
SBU.HD unit: 27 ½”H x 36”W x 19”D
Dimensions w/slide
pump base unit
• 59”H x 36”W x 48”D
Page 11
PUMPS, METERS, NOZZLES (Actual Product May Vary From Photos)
GasGuard HolsterGasGuard Nozzle
LGL156A Features■ Designed for high differential pressure applications
■ Sliding vane, positive displacement design for consistent performance
■ Motor speed operation at 1,750 rpm (60Hz)
■ U.L. listed for use on propane, butane, butane/propane mixes andanhydrous ammonia
■ LGL158 suction lift up to 4 meters (13 feet) – smaller pumps haveless lift capability
■ LGL154/156 models designed for use with single phase motors
■ Cavitation suppression liner and replaceable liner & discs
■ Ductile iron construction
■ Flanged inlet and outlet connections (2” inlet; 1-1/2” outlet)
DLF/FF075 Features■ Designed for high differential pressure applications
■ Regenerative turbine pump
■ Suitable for AG & UG tank applications
■ Motor speed operation at 3,450 rpm (60Hz)
■ Uses 7.5HP 3 phase motor, but can utiliize optional Variable Fre-quency Drive (VFD) where only single phase service is available
■ Flanged inlet and outlet connections (1-1/2; 1” outlet)
Pump
Model
Maximum
SpeedGPM HP
Max. Differential
Pressure
Recommened Bypass
Valve Setting
Relief Valve
Setting
Max. Working
Pressure
LGL156A 1,750 21 4.9 160 PSI 160 PSI 225 PSI 425 PSI
DLF/FF075 3,450 22.5 7.5 200 PSI 145 PSI N/A 400 PSI
The E:Count LT is a 12 Volt, sin-
gle product incorporating a full
digital display. It offers optional
automatic temperature compen-
sation & pulse output capability.
Features:
■ Pulse input
■ Pulse output
■ Backlit display
■ 2 auxiliary inputs
■ 4 auxiliary outputs
■ Display can also show flow
rate and total
■ Internal serial port for periph-
eral connections
Blue Moon Filter
400051-ECOUNTLT
FST-634 Features■ 1” NPT connections
■ 6”H x 5”dia
■ Flow rate: 35GPM
■ Life span: 250,000 gal
■ Micron filtration levels:
40-5 microns
Page 12
HOSE ASSEMBLIES (Actual Product May Vary From Photos)
MFH Standard
MFH GasGuard
MFH Economy
CFH Standard
GEC is proud to be a Parker Hose Distributor participating in the “Circle of Safety”, a certified pro-
gram incorporating specific procedures and documentation for the fabrication and testing of safe
reliable hose assemblies. All Parker Hose assemblies sold by GEC are fabricated and fully pressure
tested by Parker to the “Circle of Safety” certified procedure.
Parker Technical Bulletin: LPG – Hose Evacuation Process
During the life of an LPG hose assembly, it may become necessary to evacuate the propane from the hose assembly.
This is often done by opening the valve on the hose end and venting to the atmosphere. If this evacuation is performed rapidly,
it may be detrimental to the hose and cause premature hose failure.
During the use of an LPG assembly, propane will permeate through the wall of the hose. This is a known phenomenon
and regulatory agencies such as UL have maximum allowable rates of permeation (UL21-171 cc/ft/hr). The cover of the hose
is perforated to allow this permeating gas to escape, and prevent it from being trapped between the reinforcement and the cover
where it may create cover separation and blistering.
In the process of evacuating an LPG hose assembly, LPG that is permeating through the wall of the hose may become
trapped between the reinforcement layers and the inner liner of the hose. As the pressure is released from inside the hose the
LPG that is trapped between the inner liner and the reinforcement will expand as it vaporizes. The force and volume change
created by the vaporization may separate the inner liner from the reinforcement and create a tube collapse and a hose failure.
To minimize the potential for this failure, the propane should be evacuated at as slow a rate as possible in order to allow
the pressure inside the hose wall to dissipate as much as possible.
Page 13
INSTALLATION PIPING KITS (Actual Product May Vary From Photos)
T2P-114x200 - Tank to pump piping kit
DU-3Way - Optional 3-Way valve for CFH &
MFH to be configured downstream of meter with
3-way valve.
DURESS Kit - Shown installed with customer provided Unistrut and PE pipe handle.
A3209TL - Thermal latch
T2P-114X200 Assembled
T2P-1 - Tank to pump piping kit
Page 14
OPTIONS (Actual Product May Vary From Photos)
TL36 - Tank leg stands for use with 500 &
1000 WG tanks only (32.5" centerline)
1124 - Fairbanks beam scale
ECK - Pre-installed electrical conduit
DUPK - Cylinder vapor purging kit with purge
exhaust pipe and tank regulator/fittingsPK - Pneumatic kit
DURESS kit
400051-ECOUNTLT
Connections to tank service
valve
1
2
3
4
LEGEND
1-Pump Bypass
2-Meter Vapor Return
3-Pneumatic Kit
4-Purging Kit
CK - Cable kit
MA-4-CX-10
24
Page 15
Electrical Conduit Kit (ECK) Option For Dispensers(Actual Product May Vary From Photos)
Electrical option includes rigid conduit and junction box installed from switch to motor and from switch to external stub for
power connection.
NOTE: Electrician is required to complete installation. Also included is the sealing cement kit for the electrician to seal the
switch.
Conduit is stubbed thru back panel with union for simple hook-up.
Magnetic Starter: A magnetic switch with overload protection that uses a solenoid/relay to open and close contacts to a
motor circuit. It allows for remote on/off switch control and remote in-series controls such as an emergency shut-off switch. Mag-
netic starters can also provide for motor protection circuits for motors utilizing internal motor thermostats and powering internal
motor crankcase heaters to protect the motor from internal moisture condensation from cyclic use applications like dispensers.
MAGNETIC STARTER PKGS (Actual Product May Vary From Photos)
1 Phase: CTK40-24-36-ES 3 Phase: CTK40-24-36-ES-3PESO mounted on panel
Shown in DCL51SS cabinet Shown in DCS59GAL cabinet
Guide 05/12
Hose End Adapters for DOT Cylinder Filling
Part # ApplicationInlet
Connection
Outlet
Connection
5764AACME to POL
Adapter1 3⁄4” M. ACME 1⁄4” F. NPT
7193D-10
Filling of DOT
Cylinders with
POL Connections1 1⁄4” M. NPT
M. POL
(CGA 510)
7193U-10
Filling of DOT
Cylinders with
Type 1 Connections
Type 1
Connection
(1 5⁄16” M. ACME)
7193T-10
Converts 7193D-10
Adapter from POL to
a Type 1 Connection
M. POL
(CGA 510)
Type 1
Connection
(1 5⁄16” M. ACME)
7193D-10 7193U-10
7193T-10
Decals
Part # Description Size Color
AA-16Portable cylinder label -
min. order 500 pieces1 1⁄2” x 5
Black
imprint
Part # Description Size Color
CS-33DOT Cylinder Label,
Curved Only1 1⁄2” x 5”
Red & black
on white
Part # Description Size Color
V-44
Vinyl - Cylinder label, 3-in-1
• D.O.T. 1075
• NFPA hazard rating
• Warning ANSI/NPFA Pamphlet 58
4 3⁄4” x 6 3⁄4”Blue, yellow,
red & black
5764A
Part # Description Size Color
HZ-116 Vinyl - Cylinder decal-NFPA hazard 2 1⁄2” x 5”Blue, yellow
red & black
Part # Description Size Color
V-1075Vinyl
For LP Gas10 7⁄8”
Red on white
background
Part # Description Size
NFPA-7041Hazard decal-Storage tank diamond
for Propane: 100 ft. legibility7 1⁄2” x 7 1⁄2”
Part # Description Size Color
V-28CVinyl -
“Propane”
2”
letters
Red letters on
white background
Part # Description Size Color
V-55R
Vinyl - die-cut cylinder label.
2-in-1 combination
• D.O.T. 1075/Warning
• ANSI/NPFA Pamphlet 58
4 3⁄4” x 6 3⁄4”
Blue,
yellow,
red &
black
POL Plug/Dust Cap
970EZP
Part # Description Connection
970EZPPlastic plug to prevent
contamination and leakageM. POL (CGA 510)
907-12 Dust Cap OPD
970-12
Part # Description Size Color
V-23B Vinyl - “No Smoking” 4” letters Red letters on
white backgroundV-23C Vinyl - “No Smoking” 2” letters
Part # Description Size Color
P-206Polylefin - “DOT recom-
mended filling procedures”14” x 21 1⁄4”
Red on
white
Cabinet
Style Model
Cabinet ONLY
Part NumberDescription
DCS50DP DCAB-D1A-MOD Small single-door aluminum DP
DCS48DP DCAB-A48 Small two-door aluminum DP
DCS59GAL DCAB-G1V Small galvanized
DCS59GAL DCAB-G1VLL Small galvanized less louvers
DCS46PT DU26 Small single door painted steel
DCL51DP DCAB-ADP1 Large, will hold scale, aluminum DP
DCL51SS DCAB-SS1 Large, will hold scale, stainless steel
DCL49PT DU50 Large, will hold scale, painted steel, angled
DCWI75 Walk In Cabinet Walk-in aluminum DP
Cylinder Cabinets Only
www.gasequipment.com
Houston TX(800) 334-7816
Kansas City MO(800) 821-5062
Little Rock AR(800) 643-8222
Dallas TX(800) 821-1829
St. Louis MO(800) 423-4685
Richmond VA(800) 368-4013
Fayetteville NC(800) 447-1625
Orlando FL(800) 821-0631
Indianapolis IN(800) 241-1971
Atlanta GA(800) 241-4155
SINCE 1937