Cree Engineering Services Testing Laboratory (CESTL...

15
NVLAP Lab Code 500077-0 Test Report Number: PL10951-001A CESTL-R009 Rev D This report contains data that are not covered by the NVLAP accreditation. This report also contains goniometric data that was produced under subcontract by Cree Durham Technology Center, NVLAP Lab Code 500070-0. Cree, Inc | 4600 Silicon Drive | Durham, NC 27703 Page 1 of 15 Report Number: PL10951-001A Model: OSQ-HO-A-xx-2ME-40L-40K-UL Date: 06/30/17 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Moxuan Zhu Cree, Inc 4600 Silicon Drive Durham, NC 27703 Prepared By: Approved By: April Gressel, Photometric Technician Becky Kuebler, Manager Test Engineering

Transcript of Cree Engineering Services Testing Laboratory (CESTL...

NVLAP Lab Code 500077-0

Test Report Number: PL10951-001A CESTL-R009 Rev D This report contains data that are not covered by the NVLAP accreditation. This report also contains goniometric data that was

produced under subcontract by Cree Durham Technology Center, NVLAP Lab Code 500070-0.

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 1 of 15

Report Number: PL10951-001A

Model: OSQ-HO-A-xx-2ME-40L-40K-UL

Date: 06/30/17

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation

Report

Prepared For:

Moxuan Zhu

Cree, Inc

4600 Silicon Drive

Durham, NC 27703

Prepared By: Approved By:

April Gressel, Photometric Technician Becky Kuebler, Manager Test Engineering

NVLAP Lab Code 500077-0

Test Report Number: PL10951-001A CESTL-R017 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 2 of 15

Product Information

Manufacturer Cree Inc. Model Number (SKU) OSQ-HO-A-xx-2ME-40L-40K-UL Serial Number KL081J59980

LED Type MDA LEDs in 2 sections with 13 per section in 2 rows of 4 and 1 row of 5 in center, 26 total LEDs

Product Description

Brown finned metal housing with two white polymeric optical carriers with black polymeric uplight shield, and one clear polymeric optical lens covering each LED

Driver Information (Where Applicable)

Philips XI220C105V210CNA1

Length Width Height

29.75” 21.5” 4”

Sample

The following sample was submitted for evaluation

NVLAP Lab Code 500077-0

Test Report Number: PL10951-001A CESTL-R017 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 3 of 15

Key Photometric Data Sphere Output Goniophotometer

Luminous Flux 44435.0 45011.5 lm

Efficacy 128.57 129.63 lm/W

Correlated Color Temperature (CCT) 3871 K

Color Rendering Index (CRI) 72

R9 -26

Duv 0.001957

S/P Ratio* 1.46 Sphere Goniophotometer

Electrical Measurements 120V 277V 120V 277V

Input Wattage 345.60 339.50 347.23 340.45 W

Input Current 2.89 1.25 2.90 1.25 A

Input Voltage 120.00 276.96 120.06 277.06 V

Power Factor 0.998 0.984 0.998 0.983

Off-State Power 0 0 0 0 W

Total Harmonic Distortion (Voltage) 0.17 0.11 0.12 0.11 %

Total Harmonic Distortion (Amperage) 5.50 12.39 5.52 12.37 %

Note: All photometric measurements taken at 120VAC.

Luminous Intensity Distribution Goniophotometer

Max Candela 39573.7 Cd

Horizontal Angle of Max Candela 75 ˚

Vertical Angle of Max Candela 70 ˚

Key Test Parameters Sphere Output Goniophotometer

Stabilization Time 118 90 min

Total Operating Time (Stabilization + Test) 128 110 min

Ambient Temperature 24.1 25.1 ˚C

NVLAP Lab Code 500077-0

Test Report Number: PL10951-001A CESTL-R017 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 4 of 15

Chromaticity Coordinates

x y u v u’ v’ Duv

0.3877 0.3854 0.2264 0.3376 0.2264 0.5064 0.001957

Color Rendering Index Details

Ra R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14

72 69 77 84 72 69 68 80 54 -26 46 69 43 70 91

Chromaticity Diagram

NVLAP Lab Code 500077-0

Test Report Number: PL10951-001A CESTL-R017 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 5 of 15

Spectral Distribution

λ(nm) W/nm λ(nm) W/nm λ(nm) W/nm

360 0.001575 530 0.574283 700 0.091967 370 0.001235 540 0.626385 710 0.069136 380 0.001339 550 0.668030 720 0.051961 390 0.001441 560 0.711661 730 0.038894 400 0.002858 570 0.753390 740 0.028969 410 0.017902 580 0.784574 750 0.021862 420 0.096012 590 0.788313 760 0.016338 430 0.317006 600 0.757421 770 0.012621 440 0.684315 610 0.697370 780 0.009529 450 0.685373 620 0.615978 790 0.007515 460 0.257251 630 0.523702 800 0.005850 470 0.118824 640 0.433121 810 0.004803 480 0.084029 650 0.348836 820 0.003658 490 0.109321 660 0.275399 830 0.002850 500 0.213932 670 0.211677 510 0.358540 680 0.161793 520 0.489541 690 0.122246

Dominant Wavelength 578 nm Peak Wavelength: 446 nm

Spectral Power Distribution (W/nm)

NVLAP Lab Code 500077-0

Test Report Number: PL10951-001A CESTL-R017 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 6 of 15

Zonal Lumen Summary **

Zone Lumens % of Total Zone Lumens % of Total 0-5 132.6 0.3% 90-95 0 0%

5-10 399.8 0.9% 95-100 0 0% 10-15 703.3 1.6% 100-105 0 0% 15-20 1,090.3 2.4% 105-110 0 0% 20-25 1,535.9 3.4% 110-115 0 0% 25-30 1,989.5 4.4% 115-120 0 0% 30-35 2,445.3 5.4% 120-125 0 0% 35-40 2,935.9 6.5% 125-130 0 0% 40-45 3,449.3 7.7% 130-135 0 0% 45-50 3,967.7 8.8% 135-140 0 0% 50-55 4,382.8 9.7% 140-145 0 0% 55-60 4,415.0 9.8% 145-150 0 0% 60-65 4,722.5 10.5% 150-155 0 0% 65-70 5,190.3 11.5% 155-160 0 0% 70-75 4,337.4 9.6% 160-165 0 0% 75-80 2,523.8 5.6% 165-170 0 0% 80-85 706.2 1.6% 170-175 0 0% 85-90 83.9 0.2% 175-180 0 0%

Total 45011.5 lm 100%

NVLAP Lab Code 500077-0

Test Report Number: PL10951-001A CESTL-R017 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 7 of 15

Candela Plot ** Illuminance Plot **

Roadway Utilization ** Roadway Summary ** Lumens % Lamp

\

Distribution Type III, MEDIUM Downward Street Side 34782.3 77.3 % Downward House Side 10224.2 22.7 % Downward Total 45006.5 100 % Upward Street Side 0 0 % Upward House Side 0 0 % Upward Total 0 0 % Total Lumens 45006.5 100 %

NVLAP Lab Code 500077-0

Test Report Number: PL10951-001A CESTL-R017 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 8 of 15

Luminaire Classification System **

NVLAP Lab Code 500077-0

Test Report Number: PL10951-001A CESTL-R017 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 9 of 15

Candela Tabulations **

0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5

0 5513 5513 5513 5513 5513 5513 5513 5513 5513 5513 5513 5513 5513 5513 5513

2.5 5785 5841 5808 5804 5806 5782 5755 5750 5742 5735 5723 5711 5695 5680 5660

5 5994 5997 5982 5990 6007 5990 5951 5935 5924 5912 5893 5874 5847 5821 5786

7.5 5978 6026 6001 6002 6039 6091 6111 6102 6090 6078 6057 6037 6013 5989 5948

10 6370 6503 6405 6300 6203 6151 6166 6203 6209 6215 6205 6195 6172 6150 6112

12.5 7340 7516 7348 7100 6798 6506 6309 6278 6292 6305 6322 6338 6326 6314 6286

15 8551 8758 8552 8192 7738 7215 6708 6542 6501 6460 6479 6498 6502 6505 6483

17.5 9878 10050 9828 9409 8815 8145 7393 7049 6931 6814 6758 6702 6708 6714 6700

20 11164 11309 11020 10578 9922 9114 8237 7775 7554 7332 7187 7042 7000 6959 6949

22.5 12322 12404 12162 11715 10982 10128 9104 8610 8331 8052 7812 7571 7435 7299 7265

25 13119 13161 12986 12684 12060 11118 9981 9441 9156 8871 8561 8250 8013 7776 7674

27.5 13580 13617 13531 13358 12951 12106 10863 10242 9957 9672 9342 9011 8690 8369 8187

30 13848 13898 13855 13849 13604 13026 11762 11066 10738 10410 10076 9742 9378 9014 8750

32.5 14178 14259 14170 14178 14110 13734 12656 11905 11513 11122 10762 10402 10028 9654 9312

35 14687 14776 14663 14530 14464 14240 13459 12737 12276 11816 11398 10981 10614 10247 9857

37.5 15329 15386 15291 15090 14844 14635 14080 13436 12944 12453 11955 11456 11122 10787 10382

40 16092 16116 16024 15776 15404 15015 14602 14040 13566 13093 12516 11940 11591 11242 10885

42.5 16688 16766 16647 16517 16097 15431 15103 14660 14221 13782 13158 12534 12116 11699 11394

45 17446 17540 17439 17213 16841 15984 15526 15238 14861 14484 13854 13223 12742 12260 11980

47.5 17953 17874 18135 18207 17604 16782 15896 15624 15306 14986 14434 13882 13308 12733 12490

50 16987 16874 17527 18795 18727 17727 16446 16094 15830 15567 15032 14496 13859 13222 13004

52.5 15958 15710 16535 18107 19625 18934 17344 16726 16544 16361 15847 15333 14581 13829 13585

55 12245 11401 13978 17291 19248 20231 18596 17673 17451 17228 16836 16444 15588 14732 14469

57.5 4828 4418 7100 13822 18648 20692 20410 19346 18957 18567 18339 18110 17315 16520 16196

60 2361 2275 2598 6678 16377 20613 22418 21719 21245 20772 20763 20755 20317 19879 19348

62.5 1758 1684 1770 2525 10213 20398 23729 24573 24550 24528 25019 25511 25591 25672 24884

65 1386 1349 1365 1590 4531 18165 24835 27531 28542 29553 30710 31866 32412 32958 31502

67.5 1191 1174 1169 1272 2350 12734 25871 29171 31118 33066 34802 36539 37294 38050 36104

70 1113 1101 1081 1076 1392 6564 24317 29200 31242 33284 35628 37973 38773 39574 37696

72.5 912 902 964 1020 1100 2727 19007 26060 27650 29240 32209 35178 36121 37064 35847

75 728 700 725 927 909 1406 9831 19426 23021 26616 28363 30110 31190 32270 32645

77.5 544 543 550 674 842 1067 2983 12498 16204 19910 21066 22222 22653 23085 24367

80 441 433 444 466 710 881 1240 4702 7853 11003 11972 12942 12742 12543 14013

82.5 337 329 346 348 493 677 722 1548 2882 4215 4115 4015 4076 4137 4867

85 234 218 246 231 284 400 399 490 645 800 629 458 535 612 712

87.5 101 90 114 105 108 137 140 124 123 122 122 122 125 128 127

90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

NVLAP Lab Code 500077-0

Test Report Number: PL10951-001A CESTL-R017 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 10 of 15

Candela Tabulations (Continued) **

80 82.5 85 87.5 90 95 105 115 125 135 145 155 165 175 180

0 5513 5513 5513 5513 5513 5513 5513 5513 5513 5513 5513 5513 5513 5513 5513

2.5 5640 5622 5605 5585 5564 5541 5475 5419 5347 5298 5267 5222 5196 5218 5164

5 5752 5714 5677 5638 5600 5544 5429 5336 5229 5139 5082 5012 4975 4991 4953

7.5 5907 5852 5797 5736 5676 5583 5423 5277 5131 5015 4959 4891 4852 4864 4858

10 6076 6012 5949 5864 5780 5642 5431 5228 5059 4943 4901 4833 4784 4796 4806

12.5 6257 6199 6140 6038 5937 5737 5461 5218 5036 4918 4869 4800 4732 4744 4764

15 6461 6413 6365 6251 6138 5878 5517 5243 5049 4926 4863 4761 4659 4641 4642

17.5 6686 6652 6618 6500 6383 6060 5606 5301 5106 4954 4795 4550 4368 4302 4266

20 6939 6922 6906 6787 6668 6277 5731 5392 5197 4911 4533 4194 3967 3879 3822

22.5 7231 7230 7228 7113 6999 6566 5904 5513 5257 4699 4168 3786 3508 3380 3298

25 7571 7572 7572 7469 7365 6896 6106 5686 5192 4382 3787 3293 2950 2797 2707

27.5 8005 7980 7954 7851 7749 7260 6333 5874 4966 4046 3291 2703 2394 2279 2207

30 8485 8424 8362 8270 8177 7640 6594 5986 4673 3622 2697 2202 2019 1983 1972

32.5 8970 8849 8728 8663 8598 8078 6941 5927 4372 3054 2200 1933 1971 2130 2230

35 9467 9274 9080 9044 9007 8523 7361 5716 3969 2463 1923 1869 2156 2444 2556

37.5 9978 9745 9513 9482 9451 9031 7794 5465 3390 2060 1796 1867 2214 2530 2576

40 10529 10246 9963 9949 9935 9655 8196 5235 2724 1843 1707 1796 2105 2365 2367

42.5 11088 10778 10468 10464 10459 10330 8417 4908 2204 1715 1622 1708 1944 2124 2102

45 11701 11344 10987 10975 10963 11004 8417 4328 1903 1604 1531 1631 1793 1887 1863

47.5 12248 11866 11484 11462 11439 11722 8409 3501 1737 1498 1453 1576 1684 1733 1715

50 12786 12406 12027 12009 11990 12515 8500 2752 1607 1407 1400 1556 1606 1650 1644

52.5 13340 12979 12618 12668 12717 13419 8600 2361 1484 1334 1442 1576 1580 1646 1661

55 14206 13838 13471 13568 13666 14265 8602 2136 1369 1274 1552 1632 1611 1664 1672

57.5 15871 15532 15194 15133 15072 15474 8514 1919 1271 1222 1605 1729 1628 1625 1614

60 18818 18425 18033 17594 17156 17423 8604 1737 1195 1176 1527 1821 1620 1546 1521

62.5 24096 23421 22747 21558 20369 20910 9465 1590 1140 1137 1391 1836 1598 1440 1410

65 30045 28952 27859 25825 23791 24066 10753 1426 1087 1121 1342 1754 1576 1347 1311

67.5 34158 32070 29981 27717 25452 24430 9734 1222 1034 1111 1314 1575 1538 1249 1206

70 35819 32486 29153 27347 25541 22317 5632 1012 952 1091 1252 1371 1435 1147 1094

72.5 34630 30330 26030 25042 24054 17584 2416 830 866 1053 1188 1216 1256 1014 947

75 33021 28676 24332 22533 20734 12265 1375 670 775 982 1108 1076 1021 837 773

77.5 25649 22326 19002 16549 14095 5812 985 537 673 876 979 927 792 650 599

80 15482 13168 10853 9325 7796 1753 669 435 560 734 806 764 609 514 478

82.5 5598 4347 3096 2681 2265 908 430 340 437 533 608 601 452 397 356

85 812 593 373 406 440 509 271 241 297 326 389 402 318 236 216

87.5 126 109 91 101 112 162 108 109 130 117 156 171 147 128 93

90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

NVLAP Lab Code 500077-0

Test Report Number: PL10951-001A CESTL-R017 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 11 of 15

Candela Tabulations (Continued) **

0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5

92.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

97.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

100 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

102.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

105 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

107.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

110 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

112.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

115 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

117.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

122.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

125 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

127.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

130 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

132.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

135 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

137.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

140 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

142.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

145 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

147.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

150 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

152.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

155 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

157.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

160 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

162.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

165 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

167.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

170 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

172.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

175 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

177.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

180 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

NVLAP Lab Code 500077-0

Test Report Number: PL10951-001A CESTL-R017 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 12 of 15

Candela Tabulations (Continued) **

80 82.5 85 87.5 90 95 105 115 125 135 145 155 165 175 180

92.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

97.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

100 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

102.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

105 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

107.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

110 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

112.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

115 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

117.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

122.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

125 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

127.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

130 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

132.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

135 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

137.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

140 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

142.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

145 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

147.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

150 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

152.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

155 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

157.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

160 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

162.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

165 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

167.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

170 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

172.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

175 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

177.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

180 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

NVLAP Lab Code 500077-0

Test Report Number: PL10951-001A CESTL-R017 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 13 of 15

Integrating Sphere Equipment List

Description Manufacturer Model Serial Number

3M Sphere Labsphere CSTM-CSLMS-3M98-HDS 82456

CCD Array Spectrometer Otsuka MC-9801 98010165

Programmable AC Source Chroma 61603 616030000761

Single Channel Power Analyzer Xitron 2801 28011110008

Aux Lamp Power Supply Labsphere LPS-100-0833 1002104538

Goniophotometer Equipment List

Description Manufacturer Model Serial Number

AC Power Source Adaptive FC210 2300229

AC Power Source Elgar CW1251 1126A06399

Type C Goniophotometer LSI / UL 6440T 6440TE0192T

Spectroradiometer Gooch & Housego 770VIS/NIR 11414155

Power Meter Yokogawa WT210 91L220953

Test Methods Used:

Title Description

ANSI C82.77:2002 Harmonic Emission Limits- Related Power Quality Reqt’s for Lighting Equipment

CIE Pub. 13.3:1995 Method of Measuring and Specifying Color Rendering of Light Sources

CIE Pub. 15:2004 Colorimetry

IES LM-58:1994 Spectroradiometric Measurements

IES LM-79:2008 Electrical and Photometric Measurements of Solid-State Lighting Products

Reference Standard Used:

Equipment Description

3m Sphere Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number F132

Type C Goniophotometer Tungsten Halogen Omni-Directional 500W Calibration Lamp, Serial Number 97A

NVLAP Lab Code 500077-0

Test Report Number: PL10951-001A CESTL-R017 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 14 of 15

Disclaimers:

This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government.

The results contained in this report pertain only to the tested sample.

This report shall not be reproduced, except in full, without written approval of the CESTL.

* Items marked with a single asterisk are not covered by the NVLAP accreditation.

In the event that the recorded temperature is outside of 25 ± 1˚C, this is considered a non-standard condition.

** In the event that testing is subcontracted, test results in this report marked with the symbol **, or noted as “Goniophotometer”, were performed by the subcontracted laboratory identified in the footer on the first page of this report. Subcontracted testing is strictly goniophotometer based. All other tests are performed using an integrating sphere.

The goniophotometer information in the equipment list, report items marked with **, or results specifically identified as “Goniophotometer”, are the actual equipment used, and test results produced, by the subcontracted laboratory.

Additional Comments:

The photos below are intended to show the orientation and fixturing/set-up of the units under test. These are critical to understanding the results of the test given the sensitivity of many products and measurement systems to orientation and set-up considerations, and also for reproducing the conditions of the test.

Sphere Picture Goniophotometer Picture

NVLAP Lab Code 500077-0

Test Report Number: PL10951-001A CESTL-R017 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 15 of 15

Document Revision History:

Each subsequent revision of this report replaces the preceding report.

Date Rev DCN # Change Details By Approval

06/30/17 A DMS Origination A.Gressel B. Kuebler