CPX Terminal with CPI System Distributed I/O System with CP Interface CPX-CP.PSI.US Product Short Information The modular concept of the CPX electrical terminal brings performance to the next level. With the CPX-CP interface, all of the components of a CP installation system can be connected together on a single platform: CPV10/14/18 compact series, MPA10 + MPA20 series modules, CPV-SC “Smart Cubic” valve manifolds, as well as CP Eco, Compact and Standard I/O modules. Depending on the specific fieldbus protocol used, you can even integrate multiple CP interface modules. Compact Performance Benefits: Reduced Wiring The CPX-CP interface is part of a complete installation system for direct machine mounting with IP65/IP67 protection – all your pneumatics and electronics from a single source. The CPX-CP interface provides a simple hybrid CAN bus and power connection via a single cable. This cable connects the CPX/CPI modules to various CP I/O modules and valve manifolds. Combined Centralized and Distributed I/O The simplest way to mix centralized and distributed installations for optimum, clearly organized structures – easily adaptable to your specific system requirements. Wide Scope of CPX Diagnostics Comprehensive diagnostic features from the CPX world help minimize system downtimes. For more information: www.festo.com/us/cpx CPV10-VI-... MPA-CPI CPV-SC-CPI CP-E08-M8-CL CPE-E32-M8-EL Examples of availble CPI I/O modules:

Transcript of CPX Terminal with CPI System Distributed I/O System … · Distributed I/O System with CP Interface...

Page 1: CPX Terminal with CPI System Distributed I/O System … · Distributed I/O System with CP Interface CPX-CP.PSI.US Product Short Information The modular concept of the CPX ... Designation

CPX Terminal with CPI SystemDistributed I/O System with CP Interface

CPX-CP.PSI.USProduct Short Information

The modular concept of the CPXelectrical terminal brings performance to the next level.With the CPX-CP interface, all ofthe components of a CPinstallation system can be connected together on a singleplatform: CPV10/14/18 compactseries, MPA10 + MPA20 seriesmodules, CPV-SC “Smart Cubic”valve manifolds, as well as CPEco, Compact and Standard I/Omodules. Depending on the specific fieldbus protocol used,you can even integrate multipleCP interface modules.

Compact Performance Benefits:

Reduced WiringThe CPX-CP interface is part of acomplete installation system fordirect machine mounting withIP65/IP67 protection – all yourpneumatics and electronics froma single source. The CPX-CPinterface provides a simplehybrid CAN bus and power connection via a single cable.This cable connects the CPX/CPImodules to various CP I/O modules and valve manifolds.

Combined Centralized andDistributed I/OThe simplest way to mix centralized and distributed installations for optimum, clearlyorganized structures – easilyadaptable to your specific system requirements.

Wide Scope of CPX DiagnosticsComprehensive diagnostic features from the CPX world helpminimize system downtimes.

For more information: www.festo.com/us/cpx

CPV10-VI-... MPA-CPI CPV-SC-CPI CP-E08-M8-CL CPE-E32-M8-EL

Examples of availble CPI I/O modules:

Page 2: CPX Terminal with CPI System Distributed I/O System … · Distributed I/O System with CP Interface CPX-CP.PSI.US Product Short Information The modular concept of the CPX ... Designation

Subject to change CPX-CP.PSI.US 2.08

CPX Terminal with CPI SystemDistributed I/O System with CP Interface

Fieldbus

CP-E08-M8-CL

CP-E16-KL-CL CP-A04-M12-CL

CPV CP-E16-M8

DFM-12-40

MPA-CPI

CP-E32-M8-EL

CPV

CPV-SC

MPA

VTSA

Midi

Maxi

CPX-MMI

Control Architecture

Technical Data

Festo Corporation

For ordering assistance, or to findyour nearest Festo Distributor,Call: 1.800.99.FESTOFax: 1.800.96.FESTOEmail: [email protected]: www.festo.com/us

For technical support,Call: 1.866.GO.FESTOFax: 1.800.96.FESTOEmail: [email protected]

Designation CPX-CP-4-FBProtection class IP65/IP67No. of CP strings 4 per module, up to 4 full modules per CPX system.

Depending on protocol, max. 512 IN/512 OUTString length Max. 10 mMax. no. of CP slave For the following modules:modules and Pneumatic: CPV-CPI, MPA-CPI, CPVSC-CPI;I/O per string I/O: CP-CL and CP-EL, any combination up to 4 modules,

not to exceed 32 I/32 O per stringCP system cycle time 2-4 ms for entire module, fully lockedPower supply Via CPX interlinking blockCP module power supply 24 V DC, max. 1.8 A, short circuit proof, overload proof (electronic fuse)Configuration check Automatic on power on (comparison of current and saved configurations)Display components 4 x LEDs to indicate CP string errors

2 x LEDs to indicate power voltage (sensors, actuators)2 x LEDs to indicate errors and operating status

Configuration components Save button for saving current CP configurationSystem structure CPX modules and CP interface can be combined as desired

Multiple CP interface units can also be used (within existing system limitations)Addressing the CP modules and bus terminal is not required (Plug and Work®)