Cosmic Ray

72
Cosmic Ray Raquel Cossel PHYS 431 Advanced Lab Lock Haven University Pennsylvania Partners: Alexis Bowers, Max McIntyre, and Trevr Fernald Advisor: Dr. John Reid 02/02/16

Transcript of Cosmic Ray

Page 1: Cosmic Ray

Cosmic Ray

Raquel Cossel

PHYS 431 Advanced Lab

Lock Haven University

Pennsylvania

Partners: Alexis Bowers, Max McIntyre, and Trevr Fernald

Advisor: Dr. John Reid

02/02/16

Page 2: Cosmic Ray

Cossel 1

Abstract We studied the widths of cosmic ray showers by using scintillation counters to detect muons. We

varied the distance and angles of the detectors to study the shower profiles. We found that the shower

profile to be non-linear as expected. The shower profile decreased quicker with a smaller angle also as

expected.

We studied Schumann resonances using an inductive coil antenna that we designed and

constructed. When using our detector, we detected a signal at frequencies consistent with known

Schumann resonances.

Page 3: Cosmic Ray

Cossel 2

Acknowledgements I would like to acknowledge my partners in this project, Alexis Bowers, Trevr Fernald, and Max

McIntyre, for their dedication to completing our project. My understanding of our cosmic ray research

was increased with their help. Alexis and Max’s work on the electronics, as well as, Trevr’s research for

the detectors geometry and materials was detrimental to the timely and successful completion of this

project. Our instructor, Dr. John Reid’s guidance allowed for our evolution as scientists and

understanding of research techniques. Without the support of the Lock Haven University Physics

Department, the construction of our detector would not be possible.

Page 4: Cosmic Ray

Cossel 3

Table of Contents Abstract ......................................................................................................................................................... 1

Acknowledgements ....................................................................................................................................... 2

Table of Contents .......................................................................................................................................... 3

I. Background ........................................................................................................................................... 5

I.1 Fundamental Particles .................................................................................................................. 7

I.2 Detecting Cosmic Rays .................................................................................................................. 7

I.3 Schumann Resonance ................................................................................................................. 13

I.4 Lightning ...................................................................................................................................... 16

II. Experiments ........................................................................................................................................ 18

II.1 Paddle Counter ........................................................................................................................... 18

II.1.1 Discussion ............................................................................................................................ 18

II.1.1.1 Assembling the Paddle Counter Stand ............................................................................ 18

II.1.1.2 Angled Paddle Counter ................................................................................................... 20

II.1.2 Procedure ............................................................................................................................ 23

II.1.3 Data ..................................................................................................................................... 25

II.1.4 Analysis ............................................................................................................................... 28

II.2 Schumann Resonance Detector .................................................................................................. 28

II.2.1 Discussion ............................................................................................................................ 28

II.2.1.1 Schumann Resonance Detection Frame ......................................................................... 28

II.2.1.2 Testing for Breaks ........................................................................................................... 31

II.2.1.3 Connection to Lightning. ................................................................................................. 41

II.2.2 Procedure ............................................................................................................................ 41

II.2.2.1 Building the Detector ...................................................................................................... 41

II.2.2.2 Connections for the Schuman Resonance Detector ....................................................... 47

II.2.3 Data ..................................................................................................................................... 61

II.2.4 Analysis ............................................................................................................................... 63

III. Summary ......................................................................................................................................... 64

IV. Index of Figures ............................................................................................................................... 65

V. Index of Tables .................................................................................................................................... 68

VI. Index of Equations .......................................................................................................................... 68

VII. References ...................................................................................................................................... 68

Page 5: Cosmic Ray

Cossel 4

VIII. Bibliography .................................................................................................................................... 69

IX. Appendix A ...................................................................................................................................... 70

Page 6: Cosmic Ray

Cossel 5

I. Background

Cosmic rays are high-energy radiation that enter earth’s atmosphere, with energies ranging

from 1 GeV to around 108 TeV, and create air showers (Cosmic rays: Particles from outer space, n.d.). In

an air shower a primary particle collides with nuclei in the air and creates more particles which in turn

collide with other nuclei and this cycle is what creates the shower. Figure 1 shows how air showers

develop as a cosmic ray enters the atmosphere and the reactions that occur by the collisions between

particles. The initial cosmic ray does not usually reach the ground because the air showers occur high in

the atmosphere and the primary particle will lose too much energy (Bernlohr, n.d.).

Figure 1: The development of a cosmic-ray air shower that started with a primary particle.

http://www.mpi-hd.mpg.de/hfm/CosmicRay/Showers.html

The composition of cosmic rays includes hydrogen nuclei (protons), helium, and heavier atoms,

which has a makeup of 89%, 10%, and 1% respectively (Mewaldt, 1996). The cosmic rays are made up of

fundamental particles. The fundamental particles and how the particles interact is a theory called the

standard model. The standard model describes two categories that house the fundamental particles:

fermions and bosons. Fermions are the particles that are the foundation of matter. This includes the

quarks (up, down, charm, strange, top, and bottom) and the leptons (electron, electron neutrino, muon,

muon neutrino, tau, and tau neutrino). Bosons are particles that mediate the fundamental interactions

Page 7: Cosmic Ray

Cossel 6

of other particles. Bosons include gluons, photon, W±, Z, and higgs (Elert, 1998-2015). Figure 2 is a

representation that shows the relationships between each fundamental particle. The fermions are

shown in the outer circle showing quarks (orange) and leptons (green), the bosons (blue and purple) are

the center of the circle. The higgs boson particle is separated from the other boson particles because it

is the mediator particle that gives mass to quarks, the W boson and the Z boson (Riesselmann, 2015). It

is uncertain how the higgs boson interacts with the other fundamental particles.

Figure 2: A representation of the fundamental particles and the relationships between particles.

http://www.symmetrymagazine.org/image/standard-model

Page 8: Cosmic Ray

Cossel 7

I.1 Fundamental Particles Fermions are considered the “building blocks of matter” since the particles have to follow the

exclusion principle, which states that two fermions cannot be described by the same quantum number.

Therefore a cup will sit on top of a solid table instead off falling through it. The particles of the cup

cannot exist where the particles of the table exist, which is why the cup stays on top. The inability of

quarks to exist alone is why quarks are found in doublets (mesons), two bound quarks, and triplets

(baryons), three bound quarks (Elert, 1998-2015). The quarks, mesons, and baryons are also referred to

as hadrons. Hadrons encompass all combinations of quarks. Unlike quarks, leptons are able to exist on

their own. There is a subcategory of leptons called neutrinos. The neutrinos are relatively massless and

are neutral particles. The neutrino is the only particle that does not relate its mass to the Higgs-boson

particle (Neutrinos, 2015). All fermions cannot interact without the use of a mediator particle.

Bosons are the “mediator of interaction” particles. The particles are exchanged between fermions to

bind together. The gluon, photon, W+, W-, and Z particles are referred to as gauge bosons. The gauge

bosons are the mediators for the fundamental forces to occur (Elert, 1998-2015).

The fundamental forces of the standard model include the strong, weak, electromagnetic, and

gravitational forces. Since the gravitational force occurs on larger scale objects I will not discuss the

gravitational force. The strong force is mediated by gluons, the weak force is mediated by the W and Z

particles, and the electromagnetic force is mediated by photons.

I.2 Detecting Cosmic Rays Cosmic rays can be detected with a cloud chamber, and other radiation detectors. Some of these

include Geiger-Mueller Counters, scintillators, and photomultiplier tubes (PMT) (Knoll, 2000). A PMT has

a photocathode that produces electrons when hit with light. The electrons emitted from the

photocathode are concentrated and directed towards the dynodes using focusing electrodes. The

dynodes multiply the electrons through the secondary-emissions phenomenon, induced discharge of

electrons caused by an initial particle colliding with a material at a sufficient energy. Each dynode is at a

higher potential then the previous dynode. A difference in potential from dynode to dynode is created

by a parallel circuit of resistors (Kleinknecht, 1998). The dynodes are arranged in multiple geometries

but each geometry’s purpose is to direct the electrons towards a dynode at a higher potential. The

electrons are then collected at the anode and converted to an electrical pulse can be viewed on an

oscilloscope (Knoll, 2000). In Figure 3 a basic geometry for the dynodes is shown in a diagram of a PMT

with the appropriate labels that show where the previously explained parts are within the tube.

Page 9: Cosmic Ray

Cossel 8

Figure 3: A scintillator connected to a PMT with the PMT parts labeled accordingly.

http://web.stanford.edu/group/scintillators/scintillators.html

To study cosmic ray air showers we use paddle counters (PC), also referred to as scintillation

counters, which contains a scintillator and a PMT (Isaacs, 2000). A scintillator is a material that

produced light when struck by radiation. The generated light from the scintillator passes through the

photocathode in the PMT to produce the electrons that are multiplied and shown as a pulse on the

oscilloscope. Figure 4 is a PC that we have in our lab. The scintillator is located at position a) and the

PMT is located at position b) in the picture. The scintillator is connected to the end of the PMT so that

the photocathode is aligned with it. Figure 3 above shows an illustration of how the scintillation is

utilized by the PMT to show the presence of a cosmic ray incident on the oscilloscope.

Figure 4: A paddle counter made in our lab. a) Where the scintillator is housed. b) Where the PMT is housed.

When a second PC is attached to the oscilloscope on the second channel, the pulses on the un-

triggered channel are called coincidences. These coincidences occur because the oscilloscope shows

what is occurring on the second channel when a pulse is showed on the first channel. This means that

a

b

Page 10: Cosmic Ray

Cossel 9

when there is a pulse on the first channel and the second channel then there is a coincidence. A

coincidence on a screen is showed on Figure 5.

Figure 5 A visual of a coincidence on an oscilloscope obtained during research.

It was hypothesized that the graph of an air shower would look like an exponential curve. There

would be a high rate of coincidences while they were close together and then the rate would decrease

the farther apart the PCs were and the drop off would not be linear. A hand drawn graph for the

hypothesized curve is shown in Figure 6.

Page 11: Cosmic Ray

Cossel 10

Figure 6: Hypothesized graph of the width of cosmic ray air showers.

The curve was hypothesized due to the known shape cosmic ray showers. The showers are shaped

like an elongated tear drop, as shown in Figure 7. The shower starts, begins to build, and as the cosmic

rays start to lose energy the interactions start to decrease and the shower starts to die out. It was

hypothesized that the closer the PCs are the more coincidences that will be observed, due to the shape

of the showers there would be more coincidences at the center of the air shower. It was then

hypothesized that as one counter was moved away from a stationary PC it would take longer to get a

steady amount of rates. This was determined because there are less coincidences on the outer edge of

the tear drop shape.

Page 12: Cosmic Ray

Cossel 11

Figure 7: Simulated cosmic ray air shower.

http://www-ekp.physik.uni-karlsruhe.de/~kandeen/images/proton_10TeV.jpg

To test the hypothesized graph from Figure 6, a stationary PC and a moveable PC were set up

attached to an oscilloscope to view the coincidences. The coincidences were then counted in a certain

amount of time. The moveable PC was then moved some distance and coincidences were counted

again. The data that was obtained is displayed in Table 1 and graphed in Figure 8. Table 1 contains the

separation of the PCs in centimeters, the amount of time that elapsed to take the measurement in

seconds, the number of coincidences that occurred within a specified time, the rate of coincidences, and

the uncertainty in the coincidences (σc) and rate of coincidences (σR).

Page 13: Cosmic Ray

Cossel 12

Separation

(cm)

Time

(sec)

Coincidences

(counts)

σc

(countsr^1/2)

Coincidence Rate

(counts/sec)

σR

(counts/sec)

10 60 24 4.899 0.400 0.08165

30 60 21 4.583 0.350 0.07638

50 60 14 3.742 0.233 0.06236

70 120 26 5.099 0.217 0.04249

90 120 27 5.196 0.225 0.04330

110 120 15 3.873 0.125 0.03227

130 180 19 4.359 0.106 0.02422

150 210 25 5.000 0.119 0.02381

170 240 22 4.690 0.092 0.01954

190 240 18 4.243 0.075 0.01768

210 270 26 5.099 0.096 0.01889

230 270 24 4.899 0.089 0.01814

250 270 30 5.477 0.111 0.02029

270 300 20 4.472 0.067 0.01491

290 300 22 4.690 0.073 0.01563

310 300 14 3.742 0.047 0.01247

340 360 13 3.606 0.036 0.01002

380 360 18 4.243 0.050 0.01179

Table 1: Coincidences per second obtained using Paddle Counters

Page 14: Cosmic Ray

Cossel 13

Figure 8: The rate of coincidences versus the distance between paddle counters.

Figure 8 is a graph of the rate of coincidences versus the distance between the paddle counters.

The error bars along the y-axis of each point show the uncertainties in the rates of coincidences. The

uncertainty of the rates includes the uncertainty in the counts. The counts were taken by hand while

watching for a coincidence to show on the oscilloscope. There is an uncertainty in each person’s ability

to track the coincidences but that is not included in the uncertainty of the rate. The trend in Figure 8 is

non-linear as was hypothesized. The data plotted in Figure 8 correlates to the hypothesized graph in

Figure 6. The counts are higher while the PCs are closer together and get closer to zero the farther apart

the PCs get. Since air showers can be around a mile wide, taking data at larger distances could produce a

curve more similar to the hypothesized curve.

I.3 Schumann Resonance Schumann resonance is a resonance in the earth’s atmosphere that falls under the category of

extremely low frequencies (ELFs), because this resonance has its lowest Eigen-frequencies at 8, 14, 20,

26, and 32 Hz. This resonance cannot occur without an initial source of electromagnetic (EM) waves. A

good initial source of EM waves is lightening, either cloud-to-ground or cloud-to-cloud. The amplitude of

the Schumann resonance is a fraction of mV/m and it is within a 1Hz bandwidth (Simoes, et al., 2008).

Schumann resonance is being monitored by Massachusetts Institute of Technology (MIT) in

Rhode Island. MIT has two magnetic coils perpendicular to each other buried in trenches. The coils are

0.000

0.050

0.100

0.150

0.200

0.250

0.300

0.350

0.400

0.450

0.500

0 50 100 150 200 250 300 350 400

Rat

e C

oin

cid

ence

co

unts

/sec

)

Paddle Counter Separation (cm)

Cosmic Ray Coincidence Rate

Page 15: Cosmic Ray

Cossel 14

aligned with the geographic north-south and east-west axes. The coils are each 7 feet long, 3 inches in

diameter and permalloy cores with 30,000 turns of wire. Each coil is then encased in a PVC pipe with a 6

inch diameter that is also wound with 210 turns of wire. The 210 turns of wire is referred to as the

calibration coil and extends beyond the inner coils. The coils are used in conjunction with Polk’s original

antenna that is 10 meters high and has a spherical electrode with a radius of 15 inches (Huang, et al.,

1999).

The antenna to measure Schumann resonance has to be 10 meters high because the

resonance’s Eigen-frequencies are ELFs. The small frequencies require a larger antenna because the

small frequencies will not produce as prominent of an electrical pulse, since it will not disrupt the flux in

the smaller antenna as much. Figure 9 is a visual comparison between a high frequency (red) and a small

frequency (blue).

Figure 9: Visual comparison of high and low frequency sine waves.

https://mynameismjp.wordpress.com/2012/10/15/signal-processing-primer/

The core of the magnetic antenna needs to be isolated from the coil to avoid eddy currents from

occurring in the magnetically permeable core. Eddy currents occur on the surface of a magnetically

permeable material. The currents are induced by a change in magnetic flux and create a magnetic field

in the opposite direction of the original change in flux (Serway & Jewwtt Jr., 2004). Since the induced

currents produce a magnetic flux that opposed the original change in flux the current in the coil is

lessened and the output is smaller. Figure 10 is an illustration of eddy currents (B) that have been

induced in a magnetically permeable material (C) moving under a magnet (A). The magnetically

permeable material is moving in the direction of the purple arrows, an increase in magnetic flux is

shown by the black downward arrows, the blue circular arrows represents the induced eddy currents,

and the upward blue arrows are the induced magnetic flux to oppose the initial change in flux.

Page 16: Cosmic Ray

Cossel 15

Figure 10: Illustration of (A) a magnet inducing (B) eddy currents in (C) a permeable magnetic material.

To avoid the eddy currents from having a profound effect on the current in the coil and allow for

the magnetically permeability of the core to increase the antennas ability to detect the magnetic field, it

would not be ideal to use a single solid core. By using smaller insulated pieces of magnetically

permeable material, the eddy currents are decreased and unable to produce an equally large magnetic

field to oppose the original change in magnetic flux. An illustration of the difference in induced eddy

currents in a solid core versus an insulated core, as shown in Figure 11.

Figure 11: Induced eddy currents in (A) a solid core and (B) in an insulated core.

Page 17: Cosmic Ray

Cossel 16

I.4 Lightning Lightning occurs because of charge separation in a cloud. Precipitation forms in clouds with ice

crystals accumulated at the top of the cloud, ice crystals and hail in the middle region of the cloud, and

the lower regions are hail and water droplets. Collisions between the precipitations result in the

precipitations becoming charged. The positively charged precipitation travels to the top of the cloud

with upward drafts and the negatively charged precipitations accumulate at the bottom of the clouds.

As the clouds charges separate the ground becomes charged as well (Understanding Lightning Science,

n.d.). Lighting does not travel directly to ground. The charge travels in steps, called stepped leaders, to

find the quickest way to the ground. When the stepped leaders are within striking distance, a distance

where the lighting is able to connect and discharge, the ground discharges a leader upwards towards the

downward lightning strike. The upwards leaders occur during the attachment process. The process of

lightning formation is illustrated in Figure 12 below.

Figure 12: The process of lightning formation with the A) stepped leader, B) striking distance,

C) connecting leaders, and D) the attachment process.

Page 18: Cosmic Ray

Cossel 17

Once the stepped leaders attach to the leader the charge in the cloud is able to discharge. The

negative charges travel to the ground and the return stroke, which is when light travels through the

connected path from the ground to the cloud. In Figure 13A, the direction that the negative charge

travels during discharge is shown by the arrows traveling towards the ground, and in Figure 13B the

arrows are the direction that light travels during the return stroke. The flashes that are seen during and

after the initial lightning strike, or the lingering light after the strike, is caused by dart leaders. The dart

leaders are the cloud discharging the negative charge that is left after the initial lighting strike. This

negative charge and the return strokes only travel the main path of the connected lightning path. Figure

14A shows the direction of the discharge in the dart leader and Figure 14B shows the path that light

travels in the following return stroke. As you can see in Figure 14, the branches from the initial lighting

strike from Figure 13 are no longer used when the dart leader and the following return stroke occur.

Once the cloud has discharged and the dart leader can no longer travel the current path from the

connected lightning, the process starts over with the separation of charges (Uman, 1987).

Figure 13: The direction of A) negative charge discharge in the initial lightning strike

and B) light travel in the return stroke.

Page 19: Cosmic Ray

Cossel 18

Figure 14: The direction of A) negative charge discharge and B) light travel in dart leaders.

II. Experiments

II.1 Paddle Counter

II.1.1 Discussion

II.1.1.1 Assembling the Paddle Counter Stand

The stand for the paddle counter was constructed using already preassembled structures that a

previous research group built. The stand consists of a wooden base and wooden frame used to hold the

paddle counters in parallel at a fixed distance. The base requires the braces to be screwed together

where the A and B markers align on each side. The frame is then attached to the stand with long bolts.

The stand is wider than the frame. To fill the space between the frame and the stand and to keep the

frame centered, wooden blocks with holes in the center are placed between the frame and stand. The

PCs are then screwed onto the frame. There are eye hooks to attach rope to that will hold the frame at

the desired angles. Figure 15 is a picture of the stand, frame, and PCs assembled.

Page 20: Cosmic Ray

Cossel 19

Figure 15: Paddle Counter stand with paddle counters and connections securely attached.

The power cord and BNC cable for the attached paddle counters were secured to the frame and

stand, using zip ties, so that when the PC’s angle was changed the cords did not get caught on the stand.

To determine if the cords would get caught on the stand, the PCs were rotated 90 degrees up and down

and then the cables were attached. Figure 16 and Figure 17 are images of the cables attached to the

frame and the stand with zip ties.

Figure 16: Paddle counter attached to the frame with the connections secured to the frame with zip ties.

Page 21: Cosmic Ray

Cossel 20

Figure 17: The secured paddle counter connections attached to the stand with zip ties.

II.1.1.2 Angled Paddle Counter

To determine the angle of air showers, an experiment was proposed to measure coincidences

between three PCs. To do this two PCs were attached to the stand that was assembled and a third PC

was placed on a moveable table. By changing the angle of the stand and adjusting the movable table

away from the stand the occurrence of coincidences should decrease the farther away. The stands angle

is then adjusted and the table is moved again. Diagrams of the experiment setup are shown in Figure 18,

Figure 19, and Figure 20.

Page 22: Cosmic Ray

Cossel 21

Figure 18: Paddle counter setup perpendicular to the ground where A) is a frontal view and B) is a side view.

Figure 19: Paddle counter setup at 45 degree angle from the floor, where A) is the frontal view and B) is a side view.

Figure 20: Paddle counter stand setup with the paddle counter on the moveable table.

Page 23: Cosmic Ray

Cossel 22

To keep track of the triple coincidences a DAQ board was required since the oscilloscopes only

have two signal inputs. The DAQ board has four inputs so it can detect four-fold coincidences. The user

should know how to program the board using hex. To enable the proper inputs when detecting

coincidences, the computer software has to be programmed accordingly. The number of coincidences

and the enabled channels are programmed using different code. Table 2 is a table that shows all the

codes possible for this DAQ board and our use. The 0’s in the table represent the disabled inputs and the

1’s are the enabled inputs. The code for programming the type of coincidence to be taken is shown in

Table 3.

Hex Code

Inputs

0 1 2 3

0 0 0 0 0

1 0 0 0 1

2 0 0 1 0

3 0 0 1 1

4 0 1 0 0

5 0 1 0 1

6 0 1 1 0

7 0 1 1 1

8 1 0 0 0

9 1 0 0 1

A 1 0 1 0

B 1 0 1 1

C 1 1 0 0

D 1 1 0 1

E 1 1 1 0

F 1 1 1 1 Table 2: Hex code for enabled and disabled inputs.

Coincidence Hex

Code

Single-Fold 0

Double-Fold 1

Triple-Fold 2

Quadruple-Fold

3

Table 3: The type of coincidence and its corresponding Hex code.

Page 24: Cosmic Ray

Cossel 23

II.1.2 Procedure

The set up described above was assembled using the stand, a moveable table, and the three

PCs. Using masking tape we measured the distance on the floor and marked each meter as shown in

Figure 21. Then we used tape to mark the table top and the PC so that it could be realigned each time

shown in Figure 22, and then taped the bottom on the table so that it could be aligned with the floor

each time it was moved as shown in Figure 23. The DAQ board was set to allow three-fold coincidence

counts. The PC was moved to different distances and coincidence counts were taken. The code used to

take three-fold coincidence counts for this experiment is WC 00 23. This code means that three-fold

coincidence counts are taken of the enabled input 0, 1, and 2.

Figure 21: The paddle counter on the moveable table aligned with the tape on the floor.

Figure 22: The paddle counter aligned with the tape on the table top.

Page 25: Cosmic Ray

Cossel 24

Figure 23: The tape on the bottom of the table aligned with the tape on the floor.

Since the collection of trifold coincidence counts takes a substantial amount of time, 60 degrees

and 90 degrees have been successfully completed. The data is located in the following section. Table 4 is

the data obtained from the 60 degree trifold coincidence count which includes time, distance between

the PCs, the number of coincidence counts and its uncertainty, and the rate of coincidence counts and

its uncertainty. Figure 24 is the graph of the 60 degree experiment rates versus distance with the rates

uncertainty as positive and negative error bars. Figure 25 is the graph of the 60 degree experiment rates

versus distance without the data point that was taken at a large distance between the stand and the

moveable table. Table 5 is the data obtained from the 90 degree experiment which includes the time,

distance of the stand and moveable PC, the count of the coincidences and its uncertainty, and the rate

of the coincidence count and its uncertainty. The data from Table 5 is graphed in Figure 26, which is the

rate of the coincidences graphed against the distance with positive and negative error bars from the

rates uncertainty. Figure 27 is the rate of the 90 degree experiment versus the distance without the

large distance data point.

Page 26: Cosmic Ray

Cossel 25

II.1.3 Data

Time (min) Distance (cm) Coincidences

(counts) σCoincidences (counts^1/2)

Rate (Counts/min)

σRate (Count/min)

1441.02 462 255 15.969 0.18 0.0111

1348.2 320 268 16.371 0.20 0.0121

312 120 112 10.583 0.36 0.0339

1008 380 205 14.318 0.20 0.0142

4317 317 859 29.309 0.20 0.0068

1560 220 347 18.628 0.22 0.0119

1506 70 643 25.357 0.43 0.0168

1279.8 150 406 20.149 0.32 0.0157

325.8 258 107 10.344 0.33 0.0317

1050 620 140 11.832 0.13 0.0113

3127.8 500 440 20.976 0.14 0.0067

3750 1981 204 14.283 0.05 0.0038 Table 4: Data obtained from the 60 Degree trifold coincidence counts.

Figure 24: Graph of the rates versus the distance for the 60 degree trifold coincidence counts.

0.04

0.09

0.14

0.19

0.24

0.29

0.34

0.39

0.44

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Rat

e (

Co

inci

de

nce

Co

un

ts/m

in)

Distance (cm)

Page 27: Cosmic Ray

Cossel 26

Figure 25: Graph of the rates versus the distance for the 60 degree trifold coincidence counts without the long distance.

Time (min) Distance (cm) Coincidence

(counts) σCoincidence (counts^1/2)

Rate (counts/min)

σRate (Counts/min)

1009 78 677 26.0192237 0.67096135 0.02578714

187 122 123 11.0905365 0.65775401 0.05930768

1404 560 313 17.691806 0.22293447 0.012601

1013 480 228 15.0996689 0.22507404 0.01490589

373 410 101 10.0498756 0.27077748 0.02694337

1414 302 279 16.7032931 0.19731259 0.0118128

280 250 80 8.94427191 0.28571429 0.03194383

882 78 357 18.8944436 0.4047619 0.02142227

306 122 104 10.198039 0.33986928 0.03332692

1287 165 420 20.4939015 0.32634033 0.01592378

343 260 112 10.5830052 0.32653061 0.03085424

935 339 228 15.0996689 0.24385027 0.01614938

4515 460 796 28.213472 0.17630122 0.00624883

4073 1981 689 26.2488095 0.16916278 0.00644459 Table 5: Data obtained from the 90 degree trifold coincidence counts.

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.45

50 150 250 350 450 550 650

Rat

es

(Co

inci

de

nce

Co

un

ts/m

in)

Distance (cm)

Page 28: Cosmic Ray

Cossel 27

Figure 26: Graph of the rates versus the distance for the 90 degree trifold coincidence counts.

Figure 27: Graph of the rates versus the distance for the 90 degree trifold coincidence counts without the long distance.

0.15

0.25

0.35

0.45

0.55

0.65

0.75

0 500 1000 1500 2000

Rat

e (

Co

inci

de

nce

Co

un

ts/m

in)

Distance (cm)

0.15

0.25

0.35

0.45

0.55

0.65

0.75

75 175 275 375 475 575

Rat

es

(Co

inci

de

nce

Co

un

ts/m

in)

Distance (cm)

Page 29: Cosmic Ray

Cossel 28

II.1.4 Analysis

The hypothesis discussed in I.2 Detecting Cosmic Rays was that the rate would decrease non-

linearly with the distance. This hypothesis was altered to include the angle of the stand. It was then

hypothesized that the rate would decrease faster with the smaller the angle from 0 degrees to 90

degrees.

This hypothesis was supported by the decrease in rates from the 90 degree experiment to the 60

degree which can be seen between Figure 24 and Figure 26. The 60 degree experiment had a range of

rates from 0.43-0.13 coincidence counts per minute over a 550cm range separation, and the 90 degree

experiment had a range of rates from 0.67-0.17 coincidence counts per minute with a 490cm range

separation. The rates where consistently higher in the 90 degree experiment versus the 60 degree

experiment.

From Figure 25, the decrease in rates is more gradual than the decrease in rates from Figure 27. I

am not certain why the rates from the 60 degree experiment decrease more gradually than the 90

degree experiment. Figure 25 and Figure 27 both exclude the data point that was taken at a 1,981cm

separation. By excluding this point, the decline in rates at smaller distances are easier to distinguish.

Although, excluding this point also makes the decline in rates seem more linear than it actually is and

therefore is not a true representation of the data. Our data is consistent with the shape of cosmic ray

showers that is shown in Figure 7, but it is not definitive on whether or not this technique will allow for

the determination of the width of the showers.

II.2 Schumann Resonance Detector

II.2.1 Discussion

II.2.1.1 Schumann Resonance Detection Frame

To detect and study Schumann resonance it was determined that building a detector would be

an effective way to have a comprehensive understanding of how to build the detector, how the

electronics connect, how to protect the electronics, and how to view the output of the detector. The

general design of the detector was a square with rounded edges. The edges would connect at a 45

degree angle and then curved to protect the wire. This detector would be made with 2”x4” boards and

wood glue. A sketch of the originally proposed detector with dimensions is shown in Figure 28.

Page 30: Cosmic Ray

Cossel 29

Figure 28: Original design for Schumann resonance detector, where A) is a frontal view with angled corners and B) is the side

view.

The originally proposed detector was altered to minimize the concerns that were expressed by

the group. A few concerns were whether the frame would be structurally sound with wood glue holding

together the 45 degree angle corners along with those corners being rounded and how to keep the

wires from falling off. The frame structure was then adjusted to remove the 45 degree corners and have

the two edged attach perpendicularly. This adjustment can be viewed in Figure 29. This adjustment

would allow the short board to remain structurally intact since the curved corners was contained to two

boards instead of all four. This adjustment to the frame shape was sketched in Figure 30.

Figure 29: Sketch of the Schumann Resonance detection frame, where A) is the frontal view and B) is the side view.

Page 31: Cosmic Ray

Cossel 30

Figure 30: Sketch of the Schumann Resonance detection frame with curved corners, where A) is the frontal view and B) is the

side view.

To ensure that the frame is structurally sound the group discussed adding braces to the frame.

The braces were designed for two separate functions. The braces are attached at the corners of the

frame so that the perpendicular corners are reinforced. The braces are also attached to that a small

portion of the brace sits beyond the frame edge. By attaching the brace this way it also becomes a guide

for the wire that will be wrapped around the outer edge. The guides will keep the wire from slipping off

the edges of the frame. Figure 31 is a sketch of the frame with the braces at the corners.

Figure 31: Sketch of the Schumann Resonance detection frame with curved edges and triangular corner braces, where A) is the

frontal view and B) is the side view.

Page 32: Cosmic Ray

Cossel 31

II.2.1.2 Testing for Breaks

A concern when wrapping the wire around the frame is the uncertainty of whether the wire has

broken during the process. By finding a solution to determine if the wire had broken and at what

distance it broke, there is a chance that the wire could be fixed before the detector is completed. A

proposed method to test for a break in the wire is to send a pulse down the wire, determining how long

the pulse’s reflection took to return, and then determining the distance travelled by the reflection. If

the distance travelled is less than the amount of wire that is on the detector, then the wire is broken

and the distance that was calculated is where the break in the wire is. By using the speed of light and a

wire with a known length, it is possible to determine the amount of time it would take the reflection to

return. To get a reflection the pulse would have to be sent down a wire where the one end is

unattached. The reflection would hit a fixed end and return inverted, since the unattached end would

act as a node for the pulse. In the wire the pulse is an electromagnetic wave

The pulse was expected to return inverted based off of the concept of a pulse traveling down a

string to a fixed end. In a string when a pulse travels down to a fixed end, it returns inverted. When the

pulse reaches the end of the string, it creates an upward force on the boundary. Since the boundary is

stationary before the pulse acts on it, the boundary would supply a reaction force thus creating a

downward force on the string. By creating this downward force the pulse’s reflection would then return

inverted. An illustration of a pulse travelling down a string that has a fixed end is shown in Figure 32,

where a pulse is travelling towards the fixed end and then travelling away from the fixed end inverted. If

the pulse returns non-inverted then the end is considered a free end.

Figure 32: A pulse travelling down a string, where A) the pulse is travelling towards another medium and B) the inverted pulse travelling away from the other medium.

Page 33: Cosmic Ray

Cossel 32

The pulse does not invert with a free end because there is not a reaction force. The pulse

therefore does not create a force that would cause an inverted pulse. Figure 33 is an illustration of a

pulse travelling down a string with a free end, where the string is travelling towards the free end and

then away from the free end non-inverted. (Serway & Jewwtt Jr., 2004).

Figure 33: A pulse travelling down a string with a free end, where A) is the pulse traveling to right and B) the pulse is travelling to the left.

Before testing this method, we did a calculation to determine how long the reflection would

take to return by using a known length of wire. The known length of wire was 9m. The calculation

determined the reflection would return in 30ns. To be able to see the pulse and reflection, a pulse with

a width on the nanoscale was required. The only way to get a pulse on the nanoscale in our lab would be

to use a paddle counter (PC) and cosmic rays. The cosmic ray signal is enlarged by the photomultiplier

tube (PMT) and can be seen on the oscilloscope with a scale of at least 10ns. With the reflections

determined to take 30ns to return, the pulse would need to be viewed on the nanoscale as well. To test

this process, it was determined that it would be best to connect a PC to an oscilloscope and a wire with

an unattached end with a t-connector so the pulse and its reflection could be seen on the same

oscilloscope channel. Figure 34 is a depiction of the proposed set up.

Figure 34: Proposed set up to determine pulse reflections, where A) is the paddle counter, B) is the oscilloscope, and C) is the wire with an unattached end

Page 34: Cosmic Ray

Cossel 33

Pulses were visible when the PC was connected to the oscilloscope and the settings were

adjusted on the oscilloscope accordingly. Then the wire was attached to the oscilloscope and the other

end was unattached. A pulse and its reflection were then visible on the oscilloscope channel. There were

two obvious differences in the reflection than was expected. The differences in the reflection is that it

was not inverted and that the reflection took longer to return than was expected. From this, I concluded

that these wire’s unattached ends acted as a loose end instead of a fixed end. I do not have an

explanation for why the wire is behaving as a loose end. The reflection of the pulse was not inverted and

the reflection was at twice the distance that was calculated. The reflection returning in twice the

amount of time than what was expected was due to there being a difference between the cable length

and the distance the pulse had to travel to be seen on the oscilloscope a second time. The distance the

pulse travelled was twice the wire length because the pulse had to travel to the end of the wire and

then be reflected back to the oscilloscope make the total distance twice the cable length. Taking this

into account the known length was then 18m making the calculated time for the reflection to appear to

be 60ns. Even after adjusting the cable length we realized the pulse’s reflection did not return after

60ns. The reflection’s return to the oscilloscope took longer than 60ns, which meant that the pulse was

not travelling at the speed of light. To determine the speed that the pulse and its reflection are

travelling, multiple wire lengths were used and the amount of time the reflection took to appear was

studied.

To measure the time between the pulse and its reflection, the run/stop mode on the

oscilloscope was used to capture and image of the pulse and reflection and then the vertical bar mode

was used to measure the time. The vertical bar mode was also used to determine the uncertainty in

where the pulse started. This procedure was used to collect data with multiple wire lengths. Figure 35 is

a pulse and its reflection on the oscilloscope. The reflection is not inverted and is wider than the pulse,

which is due to dispersion while the pulse and the reflection travel through the wire

Page 35: Cosmic Ray

Cossel 34

Figure 35: A cosmic ray pulse and the reflected pulse after travelling the distance of the distance to the end of the wire and back to the oscilloscope.

While experimenting with the wire lengths, it became clear that the unattached wire had to be

long enough so that a pulse and its reflection could be viewed as two separate and measurable pulses,

as seen in Figure 36. If the unattached wire was too short, the pulse from the PC was visible but the

reflection travelled down the wire and back so quickly that it was undistinguishable from the pulse and

the multiple reflections after it. Figure 36 shows the clearly distinguishable original pulse but after that it

just looks like noise. To find the minimum length of wire need to see a pulse and distinguishable

reflection, multiple wires were connected until a reflection was viewed. Figure 37 is a pulse and

reflection using the shortest length of wire that reflected a measureable pulse and reflection. This

reflection occurred with a wire that had a length of 3.35m. The reflection in Figure 37 shows that its

width is larger than the pulse due to dispersion and the reflection is more than 20ns after the pulse,

which correlates with travelled distance greater than 6m.

Figure 36: A cosmic ray pulse followed by the noise caused by the reflected pulse from a short cable.

Page 36: Cosmic Ray

Cossel 35

Figure 37: A cosmic ray pulse and the reflected pulse with the shortest length cable without noise.

Since all of the wires of varying length, used to take data, were all BNC cables a linear trend in

the data was hypothesized. This was hypothesized because regardless of the size of the pulse, the pulse

and the reflection would be travelling down the same type of wire each time. This meant the speed the

pulse and the reflection travelled did not depend on the length of the wire in any way. Although, the

speed that the pulse and reflection travel could change depending on the type of wire being used.

The data that was obtained by using multiple length wires was recorded in Table 6. The table

includes the distance travelled by the pulse and reflection, the amount of time that passed between the

original pulse and the reflections return, the least count of the oscilloscope for the settings that were

used for each data point, the uncertainty in what was considered the beginning of each pulse and the

total uncertainty in the reflections return time. Table 7 is the data used to plot a weighted fit for the

data in Table 6. From the weighted fit it was determined that the slope, m, of the fit was 5.05E-09 s/m

and the y-intercept, b, is 2.80E-10 s. The speed of the reflection’s travelled distance, the total distance of

the unattached wire, is one over the slope. The speed was calculated to be 1.98E+08 m/s with an

uncertainty of +/- 0.0342E+08 m/s, which is slower than the speed of light. The speed was calculated

using Equation A1 and the uncertainty was calculated using Equation A2, which are listed in Appendix A.

With this uncertainty, the speed of the pulse and reflection is between 1.95E+08 m/s and 2.01E+08m/s.

A speed slower than the speed of light is an adequate speed since there are imperfections in the

material which would cause the pulse and reflection to travel slower.

Page 37: Cosmic Ray

Cossel 36

The data from Table 6 and Table 7 are graphed in Figure 38. The graph contains the amount of

time the reflection took to return plotted against the total distance the reflection had to travel. The

individual data points, blue, are listed in Table 6 and the error bars are the +/- of the total uncertainty in

the reflection. The solid green line is the weighted fit that was calculated using the data from Table 6

and is shown in Table 7. There is a clear linear trend in the data that corresponds to our hypothesis.

Distance Travelled

(m)

Reflection

(s)

Least Count

(s)

Uncertainty in

Pulse (s)

Uncertainty in

Reflection (s)

18.29 9.28E-08 4.00E-09 6.00E-10 4.04E-09

36.58 1.87E-07 4.00E-09 4.00E-10 4.02E-09

30.78 1.54E-07 4.00E-09 5.00E-10 4.03E-09

67.36 3.42E-07 8.00E-09 8.00E-10 8.04E-09

49.07 2.48E-07 8.00E-09 8.00E-10 8.04E-09

61.57 3.10E-07 8.00E-09 5.00E-10 8.02E-09

79.86 4.03E-07 8.00E-09 9.00E-10 8.05E-09

98.14 4.96E-07 8.00E-09 7.00E-10 8.03E-09

Table 6: Cosmic ray pulse and reflected pulse data obtained through experimentation.

Page 38: Cosmic Ray

Cossel 37

m (s/m) x (m) y (s)

5.05E-09 15.00 7.61E-08

Δm (s/m) 20.00 1.01E-07

8.72E-11 25.00 1.27E-07

b (s) 35.00 1.77E-07

2.80E-10 40.00 2.02E-07

Δb (s) 45.00 2.28E-07

4.09E-09 50.00 2.53E-07

v (m/s) 55.00 2.78E-07

1.98E+08 60.00 3.03E-07

σv (m/s) 65.00 3.29E-07

0.0342E+08 70.00 3.54E-07

75.00 3.79E-07

80.00 4.04E-07

85.00 4.30E-07

90.00 4.55E-07

95.00 4.80E-07

100.00 5.06E-07

Table 7: Values obtained from a weighted fit for cosmic ray pulses and reflected pulses.

Page 39: Cosmic Ray

Cossel 38

Figure 38: A graph of the time for the reflection to return versus the total distance travelled by the pulse and a weighted fit of the data.

To further understand if using pulses to test for breaks is a possible technique, a solid copper

core wire cut to a length of 9.144 meters was studied. To eliminate the noise caused by the cut wire

acting like an antenna, the coil was wrapped in aluminum foil with the two ends sticking out from the

foil as to not ground the wire. The coil was then attached at one end to the oscilloscope and PC and the

other end was left free. The same set up was used as was shown in Figure 34 with the addition of

aluminum foil encasing the wire. Figure 39 shows the set up with the PC, oscilloscope, and aluminum foil

encased coil of wire. Before wrapping the coil with aluminum is was not possible to see a reflected pulse

because the noise was stronger than the pulse that was being viewed. With the coil in aluminum foil a

pulse and reflection were visible.

y = 5.05E-09 x + 2.80E-10

Page 40: Cosmic Ray

Cossel 39

Figure 39: The set up for testing a known length of solid copper core wire, where A) is the paddle counter, B) is the oscilloscope, and C) is the wire wrapped in aluminum with the unattached end sticking out from the aluminum.

At first the unattached end of the wire was also enclosed in the aluminum foil and a reflection

was not visible on the oscilloscope. With the unattached end in the aluminum foil it was not possible to

tell if the wire was being unintentionally grounded. To remedy this, both ends of the wire were not

enclosed in the aluminum foil. Once the unattached end of the wire was removed from the aluminum

foil a reflection was then visible. Figure 40 is a pulse with a reflection at 108ns. The reflection travels

even slower in this wire than the original experiment. Using the speed of 2E+08 m/s that was obtained

from Figure 41, the reflection should appear around 90ns. To determine if the pulse was traveling

slower than the experimental speed, we attached the free end of the coil to channel 2 on the

oscilloscope. By attaching the free end, we will see a delayed pulse instead of a reflection of the pulse.

Figure 40: A pulse and reflection obtained by using a solid copper core bell wire.

By attaching the originally unattached end, the pulse and the delayed pulse can be seen side by

side on the oscilloscope. The set up described for the delayed pulse is depicted in Figure 41. The paddle

counter is attached to the oscilloscope and wire and shown as channel 1, which is yellow and the other

Page 41: Cosmic Ray

Cossel 40

end of the coil is attached to the oscilloscope and is shown as channel 2, which is blue. To determine

where the delayed pulse will appear requires an alteration to the calculations. The distance the pulse

travels is now half of what the reflection travelled, since the pulse travels through the wire and then

directly to the oscilloscope. The delayed pulse was expected to appear at 45ns. The delayed pulse was

actually viewed at 54ns. Seeing the delayed pulse at 54ns shows that the pulse is in fact moving slower

than the experimental speed of 2E+08m/s and that the reflection at 108ns is a true reflection. The

delayed pulse is the channel in blue, shown in Figure 42, and the yellow is the original pulse. The ability

to see the reflection in the solid copper core wire was a promising step towards determine if there are

breaks in the wire while the detection coil is being wound.

Figure 41: The delayed pulse set up, where A) is the paddle counter, B) is the oscilloscope, and C) is the aluminum foil encased coil connected to the oscilloscope by what was the unattached end.

Figure 42: A pulse in yellow and the delayed pulse in blue obtained by using a solid copper core bell wire.

Page 42: Cosmic Ray

Cossel 41

To further determine if this process would work on the thin wire that is to be used to make the

coil on the detector, a smaller diameter wire than the solid copper core wire was used. Unfortunately,

even enclosing the coil in aluminum foil did not help in eliminating enough noise to look for a reflection

from the pulse. Even using the delayed pulse method to study the wire was not very informative. The

wire produced a similar delayed pulse each time a pulse was detected but there was no way to

determine the delayed pulse actually started. From these poor result with a wire more similar in size to

the desired coil wire, it was determined that this overall method for determining if the wire has broken

while the coil is being wrapped around the frame is not plausible. The pulse reflection is most likely too

dispersed to be viewed on the oscilloscope.

II.2.1.3 Connection to Lightning.

Lightning return strokes caught my attention because of the returns strokes similarity to my

experiment with BNC cables to test for breaks in our Schumann resonance detector. The variation in the

electric field graphs looked extremely similar to the pictures of the oscilloscope that I viewed when

looking for pulse reflections. The electric field graphs show a large spike on the electric field when the

return stroke occurs and then smaller changes in the electric field for each dart leader return stroke that

occurred after the initial return stroke. The way charges travel when lightning strikes the ground

resembled how charges travel in wires. By using an oscilloscope, a PC, t-connectors, and multiple BNC

cables of varying length, I will send pulses down the wires and try to predict where the reflections will

return to the oscilloscope. My goal is to see if I can draw a conclusion on whether or not the paths

created during a lightning strike act like wires.

II.2.2 Procedure

II.2.2.1 Building the Detector

To build the Schumann resonance detection frame the first step was to cut the two 2”x4”

boards into two 34” boards and two 41” boards. To cut the appropriate length boards, the tools that

were used included a saw, a square, and a tape measurer. Figure 43 is a picture of the board being cut

with a saw after being measured and marked. This was done to obtain four boards.

Page 43: Cosmic Ray

Cossel 42

Figure 43: Cutting the boards for the frame using a saw.

The two 41” boards are to have two corners rounded. To achieve the rounded corners, a

compass was used to draw the guides for the curve. A straight edge was used to draw two lines tangent

to the curve so a rough cut could be made. Figure 44 is a picture of the frame edge after the rough cuts

were made. A saw was also used to make the rough cuts. A sander was then used to remove the excess

wood from the board and to smooth out the final curve of the wood. Figure 45 is a picture of the

smooth curve. This process was repeated for three additional curved corners.

Figure 44: The curved edge after rough cuts were made.

Page 44: Cosmic Ray

Cossel 43

Figure 45: The curved edge after the rough cut was smoothed out.

After the corners were smoothed, the next step was to remove the rounded edges that ran the

entire length of the boards. These edges needed to be removed to the wire would lay flat and parallel

along the entire width of the board. The curved edges were removed using a table saw. Figure 46 shows

the board positioned against the saw. This shows that a small amount of the wood was removed. Figure

47 is a comparison of one board before it was cut and one board after having been cut. In Figure 47 the

curved edges are clearly removed from the top of the board and that the edges are sharp edges. The

boards were then clamped together and an electric sander was used to smooth out the cuts so one

board does not end up shorter than the others. The boards being clamped together is shown in Figure

48 at two different angles.

Figure 46: The board positioned against the table saw.

Page 45: Cosmic Ray

Cossel 44

Figure 47: A comparison of the two boards, where (A) a board has had the rounded edges and

(B) a board before the rounded edges were removed.

Figure 48: The perimeter boards clamped together before being sanded from (A) angle one and (B) angle two.

To make sure the frame is structurally sound triangle braces were cut with a hand saw. Figure 49

is the braces for one side of the frame. Only one side of braces could be attached at a time because the

wood glue needs at least 24 hours to set. The other side was cut and glued at a later time. The frame

was then laid out on the table, the edges were aligned and squared, and the braces were held on with

clamps after that corner was adjusted. Figure 50 shows the braces and frame being held in place. The

braces were traced onto the frame so that after glue was applied the braces could be realigned more

easily. After the brace was glued and aligned the braces were clamped in place and then temporarily

screwed to the frame. Figure 50 shows the frame aligned and clamped before being attached and Figure

A B

Page 46: Cosmic Ray

Cossel 45

51 is after all elements were attached. In Figure 52 you can see the corner brace after it was glued to the

frame and the temporary screws were placed. The second set of braces were attached a few days later

with the same process of clamping the braces in place, traced, glued and then temporary screws placed.

Figure 53 shows the side of a corner of the frame with both braces in place.

Figure 49: Triangle braces for one side of the frame.

Figure 50: Schumann resonance detection frame before each element was attached.

Page 47: Cosmic Ray

Cossel 46

Figure 51: Schumann resonance detection frame after all elements have been attached.

Figure 52: A corner brace of the Schumann resonance detection frame with the temporary screws.

Page 48: Cosmic Ray

Cossel 47

Figure 53: A corner of the Schumann resonance detection frame after the second set of braces were attached to the frame.

II.2.2.2 Connections for the Schuman Resonance Detector

To be able to view the resonances that are to be detected, the detector needs to be able to

connect to the oscilloscope. To connect to the oscilloscope the wire that is to make the coil has to be

connected to a BNC cable in some way. The proposed way to connect the wire to the BNC cable is

through a connector that has a pin to solder a wire to and a female BNC connection on the other end, as

shown in Figure 54. From Figure 54 the wire was soldered to the gold pin on the left of the nut and the

male BNC connector were attached to the female BNC connector on the right of the nut.

Figure 54: BNC female connection to a wire connector.

http://www.showmecables.com/product/BNC-Female-Chassis-Mount-Connector.aspx

Page 49: Cosmic Ray

Cossel 48

To attach this connector to the frame, a hole was cut into one of the braces and the solder pin

and ground was inside the two braces and the female BNC was on the outside of the brace. This idea is

shown in Figure 55 shows the connection between the two corner braces, A, the connection on the

outside of the corner board, B, and the side view of the connection, C. In Figure 55, there is also a

thicker wire connected to the connector and then connected to the wire used for the coil. This thicker

wire is meant to remove strain off of the coil wire and the goal is to avoid a break in the wire causing a

faulty connection.

Figure 55: Female BNC connector connected to the wood corner brace, where A) is the connection between the two corner braces, B) is the connection on the outside of the corner brace, and C) is the side view of the connection.

A concern with the connection being attached directly to the corner brace was that the pin

would be in the way when wrapping the coil. To remedy this, the connector was attached to a piece of

hard plastic and then connected to the wood corner brace. The hole in the corner brace was larger than

the connector so that the nut that attached the connector to the plastic could be accessed if the

connector needed to be removed at some later time. Figure 56 is a depiction of the connector being

attached to the corner brace after being attached to a piece of hard plastic and shows the connection

inside the two corner braces, the connection of the connector and plastic to the outside of the corner

brace, the side view of the connection, and an enlarged side view of the plastic/connector being

attached to the wood corner brace.

Page 50: Cosmic Ray

Cossel 49

Figure 56: BNC to wire connector connected to plastic and attached to the wood corner brace, where A) is the connection between two corner braces, B) is the connector and plastic attached to the outside of the corner brace, C) is a side view of the

connector attached to the corner brace and D) is an enlarged view of the connector being attached to the corner brace.

A prototype of the sketched connection in Figure 56 was made with a piece of wood the

thickness of a corner brace with a predrilled hole, plastic with a predrilled hole, a female BNC connector

similar to Figure 54, and tape. A predrilled hole was enlarged to fit the BNC connector. The female BNC

connector was on one side and the ground and nut on the side of the pin as shown in Figure 57. The

plastic was then attached to the wood with the pin and ground sitting inside of the hole in the wood as

shown in Figure 58. Figure 59 shows the female BNC connector attached to the plastic which is attached

to the wood on the outside of the corner brace. The side view of the prototype, Figure 60, shows that

the pin sits within the hole that is in the wood, and did not interfere with wrapping the wire around the

frame. The ground, however, sticks out of the hole in the wood but the ground can we shortened to fit

within the hole. A hole was easily widened in the plastic to make it large enough to fit the connector. It

has not been determined how to cut the plastic down to a reasonable size to attach to the outside of the

corner brace on the frame. Over all the prototype was successful. Figure 61 is the plastic for the BNC

connector glued to the wooden frame from two angles and Figure 62 is the soldered BNC connector that

is going to be used to on the detector.

Page 51: Cosmic Ray

Cossel 50

Figure 57: Female BNC to wire connector attached to a piece of hard plastic.

Figure 58: Inside view of the BNC to wire connection prototype, which shows the pin and ground inside the hole in the wood.

Page 52: Cosmic Ray

Cossel 51

Figure 59: Outside view of the BNC to wire connector attached to the connection prototype, where the female BNC connection is attached to the plastic on the outside of the hole in the wood.

Figure 60: Side view of the BNC to wire connector that is attached to the prototype connection, where the pin and ground are on the left of the wood and the female BNC connector is on the right of the wood and plastic.

Page 53: Cosmic Ray

Cossel 52

Figure 61: Glued plastic connector for the BNC connection showing A) the front of the connection and B) the side of the connection.

Figure 62: Soldered BNC connector for the detector.

A B

Page 54: Cosmic Ray

Cossel 53

To connect the coil on the detector to the BNC female connector, it was determined that it

would be better to connect the coil to a panel and then use a thicker wire to connect the panel to the

BNC connector. Several prototypes were made to determine the best way to attach the coil wire and

thick wire to the panel. Figure 63 is a prototype that has the wires stick through the panel and soldered

on the underside. This prototype was dismissed because the solder was too large and would cause a

problem when gluing the panel to the wooden detection frame. Figure 64 is a prototype where the wire

were wrapped through the panel and then twisted around itself and soldered on the underside. This was

also dismissed because it would not connect easily to the wooden detection frame. Figure 65 is a

prototype that was chosen to be used on our detector. The wires are placed into the holes on the panel

and then soldered. The back of the panel is flat and was then glued to a piece of wood.

Figure 63: Panel connection prototype where the wires are through the panel and then soldered.

Page 55: Cosmic Ray

Cossel 54

Figure 64: A prototype connection where the wire are A) soldered after being B) pulled through the panel and wrapped aroung itself.

Figure 65: Panel connection prototype where the wires are soldered while sitting in the panel and then glued to a board.

A B

Page 56: Cosmic Ray

Cossel 55

After deciding on a panel and soldering technique, the next step was how to keep the coil under

tension if the soldered connection at the panel were to break. The proposed solution was a post

constructed by a bolt that had plastic washers and were held on by a nut. The prototype is shown in

Figure 66, with a thin wire used to mimic the wire that is to be used to wrap the coil. Figure 67 is a

prototype of the connection of the wire from the post to the connection panel.

Figure 66: Prototype post that will hold the tension of the coil.

Figure 67: Prototype panel connection to a post.

Page 57: Cosmic Ray

Cossel 56

The desired prototypes were then implemented on our detector frame. Figure 68 shows the bolt

that was used as the post after being placed onto the frame. The bolt is covered with heat shrink to

protect the thin wire from the treads on the bolt. Figure 68 shows three different angles of the post in

the frame. Figure 69 shows the post in the frame with the heat shrink, the two plastic washers, and the

nut. The washers are used to protect the wire from being damaged by the wooden frame and the nut

when it is tightened. Figure 69 shows the post with the washers and nut loose on the post as well as

tightened on the bolt. The bolt was also shortened and filed to be flush with the nut when it is fully

tightened.

A B

C

Page 58: Cosmic Ray

Cossel 57

Figure 68: The post in the detector with heat shrink to protect the wire with images showing A) the post on the outside of the detector, B) the post inside the detector, and C) the post from the side.

Figure 69: The posts on the detector with two plastic washers and a nut where A) the nut hasn't been tightened and B) the nut having been tightened.

The coil was wrapped onto the wooden frame that was painted white and taped to help protect

the wire from the imperfections of the wooden frame. Figure 70 shows the beginning of the first layer

being wrapped and the first layer being completely wrapped. The wire was wrapped to limit the amount

of crossover of the wires so that each wire would lay flat against the frame. After wrapping the first

layer, we taped the wire layer to protect it and to ensure that the wires didn’t move as we continued to

wrap the layers on top of it. White paper was used on the rounded edges so that there was a

background to work on since the second layer of wire was not visible with just tape between them.

Figure 71 is the taped first layer on the flat edges of the frame and the paper covered first layer of the

rounded edges of the detector.

Page 59: Cosmic Ray

Cossel 58

Figure 70: The first layer of wire wrapped on the detector showing A) a quarter of the layer and then B) the whole first layer completed.

Figure 71: The first layer of wire was covered with A) tape in the flat edges and B) paper on the curved edges.

A B

A B

Page 60: Cosmic Ray

Cossel 59

After the final layer was wrapped and taped, we did not add a third layer of white paper, the

connections were soldered together on a board. The board was cut with a hacksaw so it would fit in the

space left on the corner brace. Figure 72 is the soldered connection where the black wire is the ground

and the red wire is the output wire. These connections connect the coil to the BNC female connection.

Figure 73 is a picture of all of the connections on the detector. A stand was built to hold the detector off

the ground when it is being used outdoors.

Figure 72: The soldered connection between the coil and BNC connection where the black wire is the ground and the red wire is the output wire.

Figure 73: The connections of the coil and the BNC connector.

Page 61: Cosmic Ray

Cossel 60

Figure 74: The stand used to hold the detector showing A) the base piece that held the detector, B) the cross base piece of wood, C) a side view of the stand, and D) a side view of the stand with the cutout for the detector.

Figure 75: The detector in the stand to ensure it would be sufficient for field testing.

Page 62: Cosmic Ray

Cossel 61

Figure 76: The detector in the stand with a BNC cable connected when it was taken into the field.

II.2.3 Data

The data obtained from testing the coil in the field at Cherry Springs State Park is shown in the

figures below. Figure 77 is an image of the Fourier transform of the signal obtained from the detection

coil attached directly to the oscilloscope. Figure 78 is the Fourier Transform signal of the low pass filter

connected directly to the oscilloscope. Figure 79 is the Fourier Transform of the BNC cables connected

to only the oscilloscope. Table 8 contained impedance and resistance values pertaining to the detection

coil that were obtained using a multimeter before field testing.

Figure 77: Fourier transform of the detector signal.

Page 63: Cosmic Ray

Cossel 62

Figure 78: Fourier transform of the low pass filter only.

Figure 79: Fourier transform of the BNC cables only.

Page 64: Cosmic Ray

Cossel 63

Figure 80: Fourier transform of the detector attached to the band pass filter.

Coil Impedance (H) 1.042

Coil Resistance (kΩ) 2.769

Wire Resistance(Ω/m) 1.05

Wire & BNC Impedance (H) 1.069

Wire & BNC Resistance (kΩ) 2.768 Table 8: Impedance and resistive values related to the detection coil.

II.2.4 Analysis

Figure 77 is the Fourier Transform of the raw signal from the detector to the oscilloscope.

Multiple peaks can be seen in this signal. The largest peak is around 15Hz. This corresponds with the

14Hz frequency that is associated with the Schumann Resonance. Figure 78 and Figure 79 do not show

peaks in them that would cause false peaks in the combined signal of the detector.

In Figure 80 there is a peak in the Fourier Transform around 14Hz. This peak corresponds with the

common Schuman Resonance frequency and corresponds with the large peak in Figure 77. Viewing the

peak around 14Hz is a promising result. Since data was only collected one time, we cannot conclude

definitively that the peak in the figures is the Schumann Resonance. Based on the known values for the

Schumann Resonance and the parameters of our circuit, multiple peaks were expected. To have only

seen one peak at 14Hz could still be a Schumann Resonance peak, but more data collection would need

to be done to clarify the current results.

Page 65: Cosmic Ray

Cossel 64

III. Summary We studied cosmic ray shower width. We used three scintillation counters; two that were attached

to a stand which allowed for the angle to be adjusted and the third on a moveable table. We

hypothesized that the shower width would decrease non-linearly and that the shower width would

decrease quicker with smaller angles. Our data showed that it was non-linear and decreased quicker

with a smaller angle.

We studied Schumann Resonances. We built a detector with a wooden frame that was wrapped

with three layers of copper coil and the electronics to filter the signal. We saw results that are consistent

with the Schumann Resonances, but more data needs to be collected.

Page 66: Cosmic Ray

Cossel 65

IV. Index of Figures

Figure 1: The development of a cosmic-ray air shower that started with a primary particle. ..................... 5

Figure 2: A representation of the fundamental particles and the relationships between particles. ........... 6

Figure 3: A scintillator connected to a PMT with the PMT parts labeled accordingly.

http://web.stanford.edu/group/scintillators/scintillators.html ................................................................... 8

Figure 4: A paddle counter made in our lab. a) Where the scintillator is housed. b) Where the PMT is

housed........................................................................................................................................................... 8

Figure 5 A visual of a coincidence on an oscilloscope obtained during research. ........................................ 9

Figure 6: Hypothesized graph of the width of cosmic ray air showers. ...................................................... 10

Figure 7: Simulated cosmic ray air shower. ................................................................................................ 11

Figure 8: The rate of coincidences versus the distance between paddle counters.................................... 13

Figure 9: Visual comparison of high and low frequency sine waves. ......................................................... 14

Figure 10: Illustration of (A) a magnet inducing (B) eddy currents in (C) a permeable magnetic material.

.................................................................................................................................................................... 15

Figure 11: Induced eddy currents in (A) a solid core and (B) in an insulated core. .................................... 15

Figure 12: The process of lightning formation with the A) stepped leader, B) striking distance, .............. 16

Figure 13: The direction of A) negative charge discharge in the initial lightning strike ............................. 17

Figure 14: The direction of A) negative charge discharge and B) light travel in dart leaders. ................... 18

Figure 15: Paddle Counter stand with paddle counters and connections securely attached. ................... 19

Figure 16: Paddle counter attached to the frame with the connections secured to the frame with zip ties.

.................................................................................................................................................................... 19

Figure 17: The secured paddle counter connections attached to the stand with zip ties. ......................... 20

Figure 18: Paddle counter setup perpendicular to the ground where A) is a frontal view and B) is a side

view. ............................................................................................................................................................ 21

Figure 19: Paddle counter setup at 45 degree angle from the floor, where A) is the frontal view and B) is

a side view. .................................................................................................................................................. 21

Figure 20: Paddle counter stand setup with the paddle counter on the moveable table. ......................... 21

Figure 21: The paddle counter on the moveable table aligned with the tape on the floor. ...................... 23

Figure 22: The paddle counter aligned with the tape on the table top...................................................... 23

Figure 23: The tape on the bottom of the table aligned with the tape on the floor. ................................. 24

Figure 24: Graph of the rates versus the distance for the 60 degree trifold coincidence counts. ............. 25

Figure 25: Graph of the rates versus the distance for the 60 degree trifold coincidence counts without

the long distance. ........................................................................................................................................ 26

Figure 26: Graph of the rates versus the distance for the 90 degree trifold coincidence counts. ............. 27

Figure 27: Graph of the rates versus the distance for the 90 degree trifold coincidence counts without

the long distance. ........................................................................................................................................ 27

Figure 28: Original design for Schumann resonance detector, where A) is a frontal view with angled

corners and B) is the side view. .................................................................................................................. 29

Figure 29: Sketch of the Schumann Resonance detection frame, where A) is the frontal view and B) is the

side view. .................................................................................................................................................... 29

Page 67: Cosmic Ray

Cossel 66

Figure 30: Sketch of the Schumann Resonance detection frame with curved corners, where A) is the

frontal view and B) is the side view. ........................................................................................................... 30

Figure 31: Sketch of the Schumann Resonance detection frame with curved edges and triangular corner

braces, where A) is the frontal view and B) is the side view. ..................................................................... 30

Figure 32: A pulse travelling down a string, where A) the pulse is travelling towards another medium and

B) the inverted pulse travelling away from the other medium. ................................................................. 31

Figure 33: A pulse travelling down a string with a free end, where A) is the pulse traveling to right and B)

the pulse is travelling to the left. ................................................................................................................ 32

Figure 34: Proposed set up to determine pulse reflections, where A) is the paddle counter, B) is the

oscilloscope, and C) is the wire with an unattached end ........................................................................... 32

Figure 35: A cosmic ray pulse and the reflected pulse after travelling the distance of the distance to the

end of the wire and back to the oscilloscope. ............................................................................................ 34

Figure 36: A cosmic ray pulse followed by the noise caused by the reflected pulse from a short cable. .. 34

Figure 37: A cosmic ray pulse and the reflected pulse with the shortest length cable without noise. ...... 35

Figure 38: A graph of the time for the reflection to return versus the total distance travelled by the pulse

and a weighted fit of the data. ................................................................................................................... 38

Figure 39: The set up for testing a known length of solid copper core wire, where A) is the paddle

counter, B) is the oscilloscope, and C) is the wire wrapped in aluminum with the unattached end sticking

out from the aluminum............................................................................................................................... 39

Figure 40: A pulse and reflection obtained by using a solid copper core bell wire. ................................... 39

Figure 41: The delayed pulse set up, where A) is the paddle counter, B) is the oscilloscope, and C) is the

aluminum foil encased coil connected to the oscilloscope by what was the unattached end. ................. 40

Figure 42: A pulse in yellow and the delayed pulse in blue obtained by using a solid copper core bell

wire. ............................................................................................................................................................ 40

Figure 43: Cutting the boards for the frame using a saw. .......................................................................... 42

Figure 44: The curved edge after rough cuts were made. .......................................................................... 42

Figure 45: The curved edge after the rough cut was smoothed out. ......................................................... 43

Figure 46: The board positioned against the table saw. ............................................................................. 43

Figure 47: A comparison of the two boards, where (A) a board has had the rounded edges and ............ 44

Figure 48: The perimeter boards clamped together before being sanded from (A) angle one and (B) angle

two. ............................................................................................................................................................. 44

Figure 49: Triangle braces for one side of the frame. ................................................................................. 45

Figure 50: Schumann resonance detection frame before each element was attached. ............................ 45

Figure 51: Schumann resonance detection frame after all elements have been attached. ...................... 46

Figure 52: A corner brace of the Schumann resonance detection frame with the temporary screws. ..... 46

Figure 53: A corner of the Schumann resonance detection frame after the second set of braces were

attached to the frame. ................................................................................................................................ 47

Figure 54: BNC female connection to a wire connector. ............................................................................ 47

Figure 55: Female BNC connector connected to the wood corner brace, where A) is the connection

between the two corner braces, B) is the connection on the outside of the corner brace, and C) is the

side view of the connection. ....................................................................................................................... 48

Page 68: Cosmic Ray

Cossel 67

Figure 56: BNC to wire connector connected to plastic and attached to the wood corner brace, where A)

is the connection between two corner braces, B) is the connector and plastic attached to the outside of

the corner brace, C) is a side view of the connector attached to the corner brace and D) is an enlarged

view of the connector being attached to the corner brace. ....................................................................... 49

Figure 57: Female BNC to wire connector attached to a piece of hard plastic. ......................................... 50

Figure 58: Inside view of the BNC to wire connection prototype, which shows the pin and ground inside

the hole in the wood. .................................................................................................................................. 50

Figure 59: Outside view of the BNC to wire connector attached to the connection prototype, where the

female BNC connection is attached to the plastic on the outside of the hole in the wood. ...................... 51

Figure 60: Side view of the BNC to wire connector that is attached to the prototype connection, where

the pin and ground are on the left of the wood and the female BNC connector is on the right of the

wood and plastic. ........................................................................................................................................ 51

Figure 61: Glued plastic connector for the BNC connection showing A) the front of the connection and B)

the side of the connection. ......................................................................................................................... 52

Figure 62: Soldered BNC connector for the detector. ................................................................................ 52

Figure 63: Panel connection prototype where the wires are through the panel and then soldered......... 53

Figure 64: A prototype connection where the wire are A) soldered after being B) pulled through the

panel and wrapped aroung itself. ............................................................................................................... 54

Figure 65: Panel connection prototype where the wires are soldered while sitting in the panel and then

glued to a board. ......................................................................................................................................... 54

Figure 66: Prototype post that will hold the tension of the coil. ................................................................ 55

Figure 67: Prototype panel connection to a post. ...................................................................................... 55

Figure 68: The post in the detector with heat shrink to protect the wire with images showing A) the post

on the outside of the detector, B) the post inside the detector, and C) the post from the side. .............. 57

Figure 69: The posts on the detector with two plastic washers and a nut where A) the nut hasn't been

tightened and B) the nut having been tightened. ...................................................................................... 57

Figure 70: The first layer of wire wrapped on the detector showing A) a quarter of the layer and then B)

the whole first layer completed. ................................................................................................................. 58

Figure 71: The first layer of wire was covered with A) tape in the flat edges and B) paper on the curved

edges. .......................................................................................................................................................... 58

Figure 72: The soldered connection between the coil and BNC connection where the black wire is the

ground and the red wire is the output wire. .............................................................................................. 59

Figure 73: The connections of the coil and the BNC connector. ................................................................ 59

Figure 74: The stand used to hold the detector showing A) the base piece that held the detector, B) the

cross base piece of wood, C) a side view of the stand, and D) a side view of the stand with the cutout for

the detector. ............................................................................................................................................... 60

Figure 75: The detector in the stand to ensure it would be sufficient for field testing.............................. 60

Figure 76: The detector in the stand with a BNC cable connected when it was taken into the field. ....... 61

Figure 77: Fourier transform of the detector signal. .................................................................................. 61

Figure 78: Fourier transform of the low pass filter only. ............................................................................ 62

Figure 79: Fourier transform of the BNC cables only. ................................................................................ 62

Figure 80: Fourier transform of the detector attached to the band pass filter. ......................................... 63

Page 69: Cosmic Ray

Cossel 68

V. Index of Tables Table 1: Coincidences per second obtained using Paddle Counters .......................................................... 12

Table 2: Hex code for enabled and disabled inputs. ................................................................................... 22

Table 3: The type of coincidence and its corresponding Hex code. ........................................................... 22

Table 4: Data obtained from the 60 Degree trifold coincidence counts. ................................................... 25

Table 5: Data obtained from the 90 degree trifold coincidence counts. .................................................... 26

Table 6: Cosmic ray pulse and reflected pulse data obtained through experimentation. ......................... 36

Table 7: Values obtained from a weighted fit for cosmic ray pulses and reflected pulses. ....................... 37

Table 8: Impedance and resistive values related to the detection coil. ..................................................... 63

VI. Index of Equations Equation A 1: The units of the slope (m) in Figure 8 is seconds per meter. These units are the inverse of

the units for speed. To find the speed (v) the inverse of the slope must be taken. This speed then shows

how quickly the pulses are travelling through the wire. ............................................................................ 70

Equation A 2: The uncertainty of the speed (σv) is determined by taking the partial derivative of

Equation A 1, multiplied by the uncertainty in m (σm), squared, then square rooted. The uncertainty is

also graphed in Figure 8 as the positive and negative error bars. .............................................................. 71

VII. References Bernlohr, K. (n.d.). Cosmic-ray air showers. Retrieved 2015, from http://www.mpi-

hd.mpg.de/hfm/CosmicRay/Showers.html

Committee of Nuclear Science. (1962). Nuclear Instruments and Their Uses (Vol. 1). (A. H. Snell, Ed.) New

York: John Wiley & Sons, Inc.

Cosmic rays: Particles from outer space. (n.d.). Retrieved 2015, from CERN:

http://home.web.cern.ch/about/physics/cosmic-rays-particles-outer-space

Elert, G. (1998-2015). The Physics Hypertextbook. Retrieved from http://physics.info

Huang, E., Williams, E., Boldi, R., Heckman, S., Lyons, W., Taylor, M., . . . Wong, C. (1999, July 27). Criteria

for sprites and elves based on Schumann resonance observations. Geophysical Research, 104,

16,943-16,964. Retrieved 2015

Isaacs, A. (Ed.). (2000). Oxford Dictionary of Physics. Oxford University Press.

Kleinknecht, K. (1998). Detectors for Particle Radiation. Cambridge: Cambride University Press.

Knoll, G. F. (2000). Radiation Detection and Measurement. John Wiley & Sons, Inc.

Page 70: Cosmic Ray

Cossel 69

Mewaldt, R. A. (1996). Cosmic Rays. Macmillan Encyclopedia of Physics. Retrieved 2015, from

http://www.srl.caltech.edu/personnel/dick/cos_encyc.html

Neutrinos. (2015, July 15). Retrieved September 2015, from Fermilab:

http://www.fnal.gov/pub/science/particle-physics/experiments/neutrinos.html

Price, W. J. (1964). Nuclear Radiation Detection. McGraw-Hill Book Company.

Riesselmann, K. (2015, July 21). The Standard Model of particle physics. Retrieved September 2015, from

Symmetry: dimensions of particle physics: http://www.symmetrymagazine.org/article/july-

2015/standard-model

Serway, R. A., & Jewwtt Jr., J. W. (2004). Physics for Scientists and Engineers (Vol. 6). Belmont, CA:

Brooks/Cole-Thomson Learning.

Simoes, F., Rycroft, M., Renno, N., Yair, Y., Aplin, K. L., & Takahashi, Y. (2008). Schumann Resonances as

a Means of Investigating the Electromagnetic Environment in the Solar System. Space Science

Reviews.

Uman, M. A. (1987). The Lightning Discharge. Orlando, Florida, United States: Academic Press. Retrieved

2015

Understanding Lightning Science. (n.d.). Retrieved 2015, from National Weather Service:

http://www.lightningsafety.noaa.gov/science/science-overview.shtml

Williams, E. R., & Satori, G. (2007). Solar radiation-induced changes in ionospheric height and the

Schumann resonance waveguide on different timescales. Radio Science.

VIII. Bibliography Bernlohr, K. (n.d.). Cosmic-ray air showers. Retrieved 2015, from http://www.mpi-

hd.mpg.de/hfm/CosmicRay/Showers.html

Committee of Nuclear Science. (1962). Nuclear Instruments and Their Uses (Vol. 1). (A. H. Snell, Ed.) New

York: John Wiley & Sons, Inc.

Cosmic rays: Particles from outer space. (n.d.). Retrieved 2015, from CERN:

http://home.web.cern.ch/about/physics/cosmic-rays-particles-outer-space

Elert, G. (1998-2015). The Physics Hypertextbook. Retrieved from http://physics.info

Huang, E., Williams, E., Boldi, R., Heckman, S., Lyons, W., Taylor, M., . . . Wong, C. (1999, July 27). Criteria

for sprites and elves based on Schumann resonance observations. Geophysical Research, 104,

16,943-16,964. Retrieved 2015

Page 71: Cosmic Ray

Cossel 70

Isaacs, A. (Ed.). (2000). Oxford Dictionary of Physics. Oxford University Press.

Kleinknecht, K. (1998). Detectors for Particle Radiation. Cambridge: Cambride University Press.

Knoll, G. F. (2000). Radiation Detection and Measurement. John Wiley & Sons, Inc.

Mewaldt, R. A. (1996). Cosmic Rays. Macmillan Encyclopedia of Physics. Retrieved 2015, from

http://www.srl.caltech.edu/personnel/dick/cos_encyc.html

Neutrinos. (2015, July 15). Retrieved September 2015, from Fermilab:

http://www.fnal.gov/pub/science/particle-physics/experiments/neutrinos.html

Price, W. J. (1964). Nuclear Radiation Detection. McGraw-Hill Book Company.

Riesselmann, K. (2015, July 21). The Standard Model of particle physics. Retrieved September 2015, from

Symmetry: dimensions of particle physics: http://www.symmetrymagazine.org/article/july-

2015/standard-model

Serway, R. A., & Jewwtt Jr., J. W. (2004). Physics for Scientists and Engineers (Vol. 6). Belmont, CA:

Brooks/Cole-Thomson Learning.

Simoes, F., Rycroft, M., Renno, N., Yair, Y., Aplin, K. L., & Takahashi, Y. (2008). Schumann Resonances as

a Means of Investigating the Electromagnetic Environment in the Solar System. Space Science

Reviews.

Uman, M. A. (1987). The Lightning Discharge. Orlando, Florida, United States: Academic Press. Retrieved

2015

Understanding Lightning Science. (n.d.). Retrieved 2015, from National Weather Service:

http://www.lightningsafety.noaa.gov/science/science-overview.shtml

Williams, E. R., & Satori, G. (2007). Solar radiation-induced changes in ionospheric height and the

Schumann resonance waveguide on different timescales. Radio Science.

IX. Appendix A

𝑣 =1

𝑚

Equation A 1: The units of the slope (m) in Figure 8 is seconds per meter. These units are the inverse of

the units for speed. To find the speed (v) the inverse of the slope must be taken. This speed then shows

how quickly the pulses are travelling through the wire.

Page 72: Cosmic Ray

Cossel 71

𝜎𝑣 = √(𝜕𝑣

𝑑𝑚𝜎𝑚)2 = √(−

1

𝑚2𝜎𝑚)2

Equation A 2: The uncertainty of the speed (σv) is determined by taking the partial derivative of

Equation A 1, multiplied by the uncertainty in m (σm), squared, then square rooted. The uncertainty is

also graphed in Figure 8 as the positive and negative error bars.