Copyright © 2004 Marconi Corporation plc. All rights reserved
Product Overview
BXR-48000 Switch Router
2 Copyright © 2004 Marconi Corporation plc. All rights reserved
Objectives
Explain the hardware configuration of the BXR-48000 Identify the hardware components and their location in the
BXR-48000
3 Copyright © 2004 Marconi Corporation plc. All rights reserved
Introduction to the BXR-48000
Multiservice Switch Router Payload agnostic switching
Able to support an aggregate port capacity equal to its fabric capacity
Configurations range from 40 Gbps to 480 Gbps switching capacity
4 Copyright © 2004 Marconi Corporation plc. All rights reserved
Upper Fan TrayP
ort
car
d 7
ap
ort
car
d 7
bp
ort
car
d 7
cp
ort
car
d 7
dB
lan
kF
7p
ort
car
d 8
ap
ort
car
d 8
bP
ort
car
d 8
cP
ort
car
d 8
dF
8F
9P
ort
car
d 9
aP
ort
car
d 9
bP
ort
car
d 9
cP
ort
car
d 9
dB
lan
k
Po
rt c
ard
10a
Po
rt c
ard
10b
Po
rt c
ard
10c
Po
rt c
ard
10d
Bla
nk
F10
Po
rt c
ard
11a
Po
rt c
ard
11b
Po
rt c
ard
11c
Po
rt c
ard
11d
F11
F12
Po
rt c
ard
12a
Po
rt c
ard
12b
Po
rt c
ard
12c
Po
rt c
ard
12d
Bla
nk
Lower Fan Tray
Air Inlet Air InletAir Inlet
Filter
PCM
A0
PCM
B0
PCM
A1
PCM
B1
BXR-48000 Hardware Configuration
Upper Fan Tray
Po
rt c
ard
1a
po
rt c
ard
1b
po
rt c
ard
1c
po
rt c
ard
1d
Pro
tect
ion
Fab
ric
Fab
ric
1p
ort
car
d 2
ap
ort
car
d 2
bP
ort
car
d 2
cP
ort
car
d 2
dF
abri
c 2
Fab
ric
3P
ort
car
d 3
aP
ort
car
d 3
bP
ort
car
d 3
cP
ort
car
d 3
dS
CP
X
Po
rt c
ard
4a
Po
rt c
ard
4b
Po
rt c
ard
4c
Po
rt c
ard
4d
Fab
ric
4P
ort
car
d 5
aP
ort
car
d 5
bP
ort
car
d 5
cP
ort
car
d 5
dF
abri
c 5
Fab
ric
6P
ort
car
d 6
aP
ort
car
d 6
bP
ort
car
d 6
cP
ort
car
d 6
dS
CP
Y
TC
M0
T
CM
1
AIM
Lower Fan Tray
Air Inlet Air InletAir Inlet
Filter
PCM
A0
PCM
B0
PCM
A1
PCM
B1
Chassis A
Chassis B
5 Copyright © 2004 Marconi Corporation plc. All rights reserved
Port Layout – Fabric 6 Example
Fab
ric
6
SC
P Y
A B C DSlots
1
2
3
4
1
8
16
Port Numbers
Ports for Fabric 6 are identified as 6A1, 6B16, etc.
6B16
6 Copyright © 2004 Marconi Corporation plc. All rights reserved
BXR-48000 Chassis
Power Switching, Interfaces and Control Cooling Expansion from single chassis to dual chassis can be a hitless field upgrade (although we recommend an initial dual-chassis installation if possible)
Upper Fan Tray
Card Cages
Lower Fan Tray
Power Conditioning
Modules
7 Copyright © 2004 Marconi Corporation plc. All rights reserved
BXR-48000 SCP
Y
X
+
Serial Port
SELECT Button
System LEDsSystem LEDs
NEXT Button
Ethernet Port
NMI Button
Display
Reset Button
8 Copyright © 2004 Marconi Corporation plc. All rights reserved
BXR-48000 Dual SCP Configuration
Optional dual SCPs provide protection The primary active SCP emits a "heartbeat" at regular intervals
Primary/Secondary vs. Active/Standby SCPs Primary – is set as the default SCP to control the system after it boots Secondary – is set as the backup SCP should the primary fail Active – is the SCP that is currently controlling the system Standby – is the backup SCP
9 Copyright © 2004 Marconi Corporation plc. All rights reserved
BXR-48000 Fabric Modules
Variable-length packet fabric Support up to 12(+1), 40 Gbps
fabrics per chassis One fabric for every four port
cards Contiguous population Protocol agnostic fabrics
Data is distributed evenly across all fabrics
N+1 fabric protection Scales from 240 Gbps to a
480 Gbps system with fabric redundancy
Fail over protection is provided by a "hitless" reconstruction process
LEDs
Ejection/InsertionLevers
Lock
+
10 Copyright © 2004 Marconi Corporation plc. All rights reserved
BXR-48000 Port Cards
Input/Output Modules Each port card supports
up to 10 Gbps of full-duplex capacity
Three types: ATM IP-Aware (IPA) ATM Packet over SONET (POS)
+
OC-3c
OC-12c
LEDs
OC-48c
11 Copyright © 2004 Marconi Corporation plc. All rights reserved
ATM Port Cards
Cell-based interfaces capable of normal ATM functions PVC, SVC, SPVC Traffic management, per-VC queuing, scheduling ILMI, PNNI routing
ATM port card hardware 16 port OC-3c/STM-1 in multimode and single mode 16 port OC-12c/STM-4* in multimode and single mode 4 port OC-48c/STM-16 in single mode 1 port OC-192c/STM-64 in single mode
* Each port configurable as OC-12c/STM-4 or OC-3c/STM-1
Ejection/InsertionLevers
(with locks)
12 Copyright © 2004 Marconi Corporation plc. All rights reserved
IP-Aware (IPA) ATM Port Cards
An IP-aware ATM interface has ATM capabilities plus capabilities in an IP/MPLS network: Hop-by-hop routing when there is no LSP for the destination Can originate or terminate an LSP, encapsulating/decapsulating
packets using RFC 1483/2684 (bridged/routed PVCs) Support for ATM and MPLS control planes on the same port Pseudo Wire Emulation Edge-to-Edge (PWE3) Provider Edge (PE) capability
A topology change can make a transit LSR become an LER, the IPA card performs both roles. Ingress and egress to the MPLS network require IP look-ups A network failure could cause a transit LSR to unexpectedly become
an LER that cannot perform IP lookups
13 Copyright © 2004 Marconi Corporation plc. All rights reserved
IPA ATM Port Card Hardware
Port card types, listed by interface: 8 port OC-3c/STM-1 in multimode and single mode 8 port OC-12c/STM-4* in multimode and single mode 2 port OC-48c/STM-16 in single mode
* Each port configurable as OC-12c/STM-4 or OC-3c/STM-1
14 Copyright © 2004 Marconi Corporation plc. All rights reserved
Packet over SONET (POS) Port Cards
SONET-based IP interfaces allow direct connection of IP devices
OC-12c and OC-48c POS port cards can be trunks for aggregated IP traffic
Hop-by-hop routing supported Can originate or terminate an LSP
Provider Edge (PE) functionality Multiservice capability over MPLS with PWE3 toward the network
core
15 Copyright © 2004 Marconi Corporation plc. All rights reserved
POS Port Card Hardware
Port card types, listed by interface: 12 port OC-3c/STM-1 in multimode and single mode 12 port OC-12c/STM-4* in multimode and single mode 4 port OC-48c/STM-16 in single mode
* Each port configurable as OC-12c/STM-4 or OC-3c/STM-1
16 Copyright © 2004 Marconi Corporation plc. All rights reserved
Port Card Scheduling and Queuing
POS and IPA port cards have 16 hardware queues Room to concurrently support ATM service categories,
Diffserv, IntServ and best-effort IP Configurable strict and weighted round robin queues Provides support for unique service offerings
17 Copyright © 2004 Marconi Corporation plc. All rights reserved
BXR-48000 Card Carrier/TCM
The card carrier supports: TCM and AIM The TCM(s) are optionally
redundant The TCM provides system
synchronization and manages the timing sources: Primary and secondary line
timing sources Redundant BITS sources Internal Stratum 3E clock
TCM(s) are located on chassis A only
+
TCMTCM
Card CarrierCard Carrier
18 Copyright © 2004 Marconi Corporation plc. All rights reserved
BXR-48000 Card Carrier/AIM
Supports five alarm relays Has six LEDs which are:
LED1 - OK (green) LED2 - Critical Alarm (blinking red) LED3 - Major Alarm (red) LED4 - Minor Alarm (amber) LED5 - Unused LED6 - Unused
Located on chassis A only
+
AIMAIM
Card CarrierCard Carrier
19 Copyright © 2004 Marconi Corporation plc. All rights reserved
BXR-48000 TIM
The physical connection point for external timing sources on the BXR-48000
Accessible by removing a small cover on the back of chassis A
TIM
20 Copyright © 2004 Marconi Corporation plc. All rights reserved
BXR-48000 PCMs
Requires –48v DC power 2(+2) redundancy per
chassis PCMs provide:
EMI filtering Short-term energy storage Reverse feed polarity
protection Reverse discharge
protection Surge suppression Under voltage trip
+
PCM
PCM
A0
PCM
B0
PCM
A1
PCM
B1
21 Copyright © 2004 Marconi Corporation plc. All rights reserved
BXR-48000 System Cooling
Two removable fan trays with four fans in each tray
If a single fan fails, the remaining seven fans increase speed to compensate for the loss
Filter and protective screen keeps debris from the chassis
Filter
Protective Screen
Air inlet
Air Exhaust
+
Fan Trays
22 Copyright © 2004 Marconi Corporation plc. All rights reserved
BXR-48000 MCP
Provides alarm and control interface between the mothercard and the active SCP
Consists of a high performance processor and memoryF
ab
ric
Po
rt c
ard
Po
rt c
ard
Po
rt c
ard
Po
rt c
ard
Fa
bri
c
Po
rt c
ard
Po
rt c
ard
Po
rt c
ard
Po
rt c
ard
SC
P Y
Fa
bri
c
Po
rt c
ard
Po
rt c
ard
Po
rt c
ard
Po
rt c
ard
Fa
bri
c
Po
rt c
ard
Po
rt c
ard
Po
rt c
ard
Po
rt c
ard
SC
P X
TC
M 0
TC
M 1
MCP MCP MCP MCP MCP MCP MCP MCP MCP MCP MCP
MCP
MCP MCP MCP MCP MCP MCP MCP MCP MCP MCP
23 Copyright © 2004 Marconi Corporation plc. All rights reserved
BXR-48000 Cable Management System
Two cable management systems per chassis located: Above the upper card cage Below the lower card cage
Organize and protect fiber cables in the chassis
Protective Doors
Cable Management
Cable Management
24 Copyright © 2004 Marconi Corporation plc. All rights reserved
BXR-48000 Management and Configuration
The BXR-48000 supports IP Management: ATM over port card interfaces Over the SCP’s Ethernet port
Can configure remotely using: Command Line Interface (CLI) Element Manager
The SNMP BXR-48000 can be used with Service On Data (SOD) Release 2.0 – SOn-D v2.4
25 Copyright © 2004 Marconi Corporation plc. All rights reserved
Summary
Explained the hardware configuration of the BXR-48000 Identified the hardware components and their location in the
BXR-48000