Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1...
Transcript of Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1...
![Page 1: Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1 Wired Controller KJR-12B • All basic function (Mode, fan speed, temperature)](https://reader034.fdocuments.in/reader034/viewer/2022042120/5e997562827cf81dbe565aec/html5/thumbnails/1.jpg)
Technical Support Department
Controllers of
Light Commercial Units
![Page 2: Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1 Wired Controller KJR-12B • All basic function (Mode, fan speed, temperature)](https://reader034.fdocuments.in/reader034/viewer/2022042120/5e997562827cf81dbe565aec/html5/thumbnails/2.jpg)
Part 1 Wired Controller
![Page 3: Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1 Wired Controller KJR-12B • All basic function (Mode, fan speed, temperature)](https://reader034.fdocuments.in/reader034/viewer/2022042120/5e997562827cf81dbe565aec/html5/thumbnails/3.jpg)
KJR-12B
• All basic function (Mode, fan speed, temperature)
• Economic function
• Swing function
• Follow me function
• Auto-restart function
• Standard for duct units and applicable for all kinds of indoor units.
Functions:
Size:118*118*18mm (Cover closed); 118*173*18
Connection:5-core wires with plug; connected to the reserved socket from the indoor display board
![Page 4: Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1 Wired Controller KJR-12B • All basic function (Mode, fan speed, temperature)](https://reader034.fdocuments.in/reader034/viewer/2022042120/5e997562827cf81dbe565aec/html5/thumbnails/4.jpg)
KJR-120C
• All basic function• 7-days Weekly schedule setting
• Control of auto-lifting panel of cassette
• Individual louver control of cassette panel
• Dual-way communication (show error codes)
• Auto-restart function
• ESP setting for A6 duct
• Applicable for all inverter indoor units.
Functions:
Size:120*122*18.5 mm
Connection:4-core wires with plug; connected to the reserved socket from the indoor main PCB
![Page 5: Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1 Wired Controller KJR-12B • All basic function (Mode, fan speed, temperature)](https://reader034.fdocuments.in/reader034/viewer/2022042120/5e997562827cf81dbe565aec/html5/thumbnails/5.jpg)
KJR-120G
Functions:
Size:120*123*18.5 mm
Connection:2 wires without polarity; Need an adapter board connected to the indoor main PCB
• All function of KJR-120C
• Max. 16 indoor units can be controlled at the same time
• Dual-way communication (show error codes)
• Screwed 2 wires connection without polarity
• Applicable for all inverter indoor units.
To KJR-120G
To indoor PCB
![Page 6: Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1 Wired Controller KJR-12B • All basic function (Mode, fan speed, temperature)](https://reader034.fdocuments.in/reader034/viewer/2022042120/5e997562827cf81dbe565aec/html5/thumbnails/6.jpg)
Functions:
Size:183*136*33mm
Connection:2 wires without polarity; connected to the indoor S1, S2 terminal (or X, Y, E terminal for old models)
• All basic functions
• Multi-touched full-colored HD (1024*600) LCD display
• Multiple control methods and auto-set: single control, zone control, 2 units rotation and backup, group control
• Max. 64 indoor units can be controlled independently
• ESP setting for A6 duct
• Applicable for all indoor units (Group control module NIM01 requested for ON-OFF units).
![Page 7: Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1 Wired Controller KJR-12B • All basic function (Mode, fan speed, temperature)](https://reader034.fdocuments.in/reader034/viewer/2022042120/5e997562827cf81dbe565aec/html5/thumbnails/7.jpg)
Part 2 Central Controller
(from Midea CAC)
![Page 8: Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1 Wired Controller KJR-12B • All basic function (Mode, fan speed, temperature)](https://reader034.fdocuments.in/reader034/viewer/2022042120/5e997562827cf81dbe565aec/html5/thumbnails/8.jpg)
Functions:
Size:180*120*63mm; 180*153*63 (Cover opened)
Connection:X, Y, E terminal of indoor unit (or S1, S2 terminal for new unit)
• Max. 64 indoor units group control or individual setting• Clear and bright LCD screen• Backlight• Parameter query• Error code query of each unit• Mode lock, Key lock, Remote controller lock • Permanent schedule setting storage
CCM03
![Page 9: Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1 Wired Controller KJR-12B • All basic function (Mode, fan speed, temperature)](https://reader034.fdocuments.in/reader034/viewer/2022042120/5e997562827cf81dbe565aec/html5/thumbnails/9.jpg)
Functions:
Size:180*120*65mm
Connection:X, Y, E terminal of indoor unit (or S1, S2 terminal for new unit)
• All functions of CCM03• Touch key design• Filter clean reminding
CCM30
![Page 10: Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1 Wired Controller KJR-12B • All basic function (Mode, fan speed, temperature)](https://reader034.fdocuments.in/reader034/viewer/2022042120/5e997562827cf81dbe565aec/html5/thumbnails/10.jpg)
Functions:
Size:
Connection:X, Y, E terminal of indoor unit (or S1, S2 terminal for new unit)
CCM09
• 7-days Weekly schedule setting• Max. 64 indoor units group control or individual setting• Clear and bright LCD screen• with backlight• Parameter query• Error code query• Mode lock, Key lock, Remote controller lock • Permanent schedule setting storage
180*120*63mm; 180*153*63 (Cover opened)
![Page 11: Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1 Wired Controller KJR-12B • All basic function (Mode, fan speed, temperature)](https://reader034.fdocuments.in/reader034/viewer/2022042120/5e997562827cf81dbe565aec/html5/thumbnails/11.jpg)
MD-CCM08/E
• BMS Gateways are compatible to multiple communication protocol of BACnet, LonWorks, Modbus.• Connectible to BMS or Smart Home system
MD-LonGW64/E CCM18-A
BMS Gateways
![Page 12: Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1 Wired Controller KJR-12B • All basic function (Mode, fan speed, temperature)](https://reader034.fdocuments.in/reader034/viewer/2022042120/5e997562827cf81dbe565aec/html5/thumbnails/12.jpg)
CCM03 or
CCM09
Max. 64
X, Y, E (or S1, S2) X, Y, E (or S1, S2)
Single Group Controller
![Page 13: Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1 Wired Controller KJR-12B • All basic function (Mode, fan speed, temperature)](https://reader034.fdocuments.in/reader034/viewer/2022042120/5e997562827cf81dbe565aec/html5/thumbnails/13.jpg)
Group Control by PC
CCM03
CCM03
Max. 64
Max. 16
Max. 64
X, Y, E (or S1, S2)
F1,F2,E
F1,F2,E
X, Y, E (or S1, S2)
X, Y, E (or S1, S2) X, Y, E (or S1, S2)
Soft dog
RS485/RS232
Converter
Network control
software
![Page 14: Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1 Wired Controller KJR-12B • All basic function (Mode, fan speed, temperature)](https://reader034.fdocuments.in/reader034/viewer/2022042120/5e997562827cf81dbe565aec/html5/thumbnails/14.jpg)
BMS Access Solution
![Page 15: Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1 Wired Controller KJR-12B • All basic function (Mode, fan speed, temperature)](https://reader034.fdocuments.in/reader034/viewer/2022042120/5e997562827cf81dbe565aec/html5/thumbnails/15.jpg)
BMS Access Solution
![Page 16: Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1 Wired Controller KJR-12B • All basic function (Mode, fan speed, temperature)](https://reader034.fdocuments.in/reader034/viewer/2022042120/5e997562827cf81dbe565aec/html5/thumbnails/16.jpg)
BMS Access Solution
Max. 64X, Y, E (or S1, S2) X, Y, E (or S1, S2)X, Y, E (or S1, S2)
TCP/IP RTU
There are 2 connection methods for the Modbus system: either TCP/IP or RTU
![Page 17: Controllers of Light Commercial Unitsmidea.com.ge/uploads/client/Uploads/Catalogues/Service...Part 1 Wired Controller KJR-12B • All basic function (Mode, fan speed, temperature)](https://reader034.fdocuments.in/reader034/viewer/2022042120/5e997562827cf81dbe565aec/html5/thumbnails/17.jpg)
Midea Strategic Partners:
THANKSFOR YOUR ATTENTION