Control of Bioaerosols

40
Control of Bioaerosols

description

Control of Bioaerosols. Concentrations in Air. Concentrations of indoor bacteria range from

Transcript of Control of Bioaerosols

Page 1: Control of Bioaerosols

Control of Bioaerosols

Page 2: Control of Bioaerosols

Concentrations in Air

• Concentrations of indoor bacteria range from <100-1500 cfu/m3; avg 0-500– heated dwellings lower

• Avg concentrations of outdoor bacteria 200-1000

• Avg concentrations of indoor Fungi range from 10-500

• Avg concentrations of Outdoor Fungi range from 100-1000

Page 3: Control of Bioaerosols

Air Quality Control Methods

SourceControl

VentilationPressureControl

AirTreatment

Page 4: Control of Bioaerosols
Page 5: Control of Bioaerosols
Page 6: Control of Bioaerosols
Page 7: Control of Bioaerosols

Air Filtration

• Part of most HVAC systems• Hospitals have very intricate systems• No universal standard method for evaluating

filter performance– Thus advertised efficiencies may be misleading

• Most difficult range of particles to filter 0.2 to 0.3 micron; generally particles categorized as > 0.5 or < 0.5 microns

• Peak Particle Removal with 12-15 ACH

Page 8: Control of Bioaerosols

Types of Filters

• Fiberglass- typical household filter 5-7% effective

• Electronic- lose filtering 50% capacity in first week

• HEPA- High Efficiency Particulate Air, 99.97% of pollutants at 0.3 microns

• ULPA- Ultra Low Penetration Air, 99.9997% of particles as 0.1 micron

• Electrostatic- “static charged”, 95%

Page 9: Control of Bioaerosols
Page 10: Control of Bioaerosols
Page 11: Control of Bioaerosols
Page 12: Control of Bioaerosols
Page 13: Control of Bioaerosols
Page 14: Control of Bioaerosols
Page 15: Control of Bioaerosols
Page 16: Control of Bioaerosols
Page 17: Control of Bioaerosols
Page 18: Control of Bioaerosols

Other Air Treatments

• Ionizer- negative ion generation

• Ozone- good disinfectant, safety risk

• UV- good disinfectant, 253.7nm, long exposure times?

Page 19: Control of Bioaerosols
Page 20: Control of Bioaerosols
Page 21: Control of Bioaerosols

Cundith et al.Console filtration

Page 22: Control of Bioaerosols

Cundith et al., Meat Processing Plant

• Deployed EP filters with scanning UV

• Three Rooms (100% recirculation)– Processing- 10ºC, 110m3, 3 m/min– Chill Cooler- 0-2ºC, 130m3, 21 m/min– Aging Cooler- 0-2ºC, 360m3, 8m/min

Page 23: Control of Bioaerosols
Page 24: Control of Bioaerosols
Page 25: Control of Bioaerosols
Page 26: Control of Bioaerosols
Page 27: Control of Bioaerosols

Kujundzic E, et al..•  

Effects of ceiling-mounted HEPA-UV air filters on airborne bacteria concentrations in an indoor therapy pool building. J Air Waste Manag Assoc. 2005 Feb;55(2):210-8.

The purpose of this study was to assess the effectiveness of a new generation of high-volume, ceiling-mounted high-efficiency particulate air (HEPA)-ultraviolet (UV) air filters (HUVAFs) for their ability to remove or inactivate bacterial aerosol. In an environmentally controlled full-scale laboratory chamber (87 m3), and an indoor therapy pool building, the mitigation ability of air filters was assessed by comparing concentrations of total bacteria, culturable bacteria, and airborne endotoxin with and without the air filters operating under otherwise similar conditions. Controlled chamber tests with pure cultures of aerosolized Mycobacterium parafortuitum cells showed that the HUVAF unit tested provided an equivalent air-exchange rate of 11 hr(-1). Using this equivalent air-exchange rate as a design basis, three HUVAFs were installed in an indoor therapy pool building for bioaerosol mitigation, and their effectiveness was studied over a 2-year period. The HUVAFs reduced concentrations of culturable bacteria by 69 and 80% during monitoring periods executed in respective years. The HUVAFs reduced concentrations of total bacteria by 12 and 76% during the same monitoring period, respectively. Airborne endotoxin concentrations were not affected by the HUVAF operation.

Page 28: Control of Bioaerosols

Laboratory Control

• BSCs

• Centrifuge containment

• HVAC

Page 29: Control of Bioaerosols

Class I

• Personnel and Environmental Protection

• No Product Protection• Similar to fume hood

with HEPA exhaust• 75 LPM• Hard-ducted to BLDG

exhaust• 0.5 inches water

Page 30: Control of Bioaerosols

Class I

• Some have integral blower

• Must be turned off in case of BLDG exhaust failure

• Good design to surround all positive pressure plenums with vacuum

Page 31: Control of Bioaerosols

Class IIA/B3 (Now Class II A2)

• 30/70 exhaust/recirculation• HEPA filtered on exhaust

and recirculation• 75 LPM• Hard-ducting not

recommended • Not rated for volatiles or

toxics

Page 32: Control of Bioaerosols

Class IIB1• Originated with NCI designed

cabinet• 70/30 exhaust/recirculation• HEPA filtered on exhaust,

recirculation and inflow• Personnel, environment and

product protection• 100 LPM• 70% downflow through rear grill;

30% front grill• Hard-ducted; preferably

dedicated

Page 33: Control of Bioaerosols

Class IIB2

• Total exhaust • Personnel, environment and

product protection• HEPA filtered on inflow and

exhaust• 100 LPM• Hard-ducted;1.5 inches

water; must be interlocked; ideally dedicated

• With internal blower may not be hard-ducted

Page 34: Control of Bioaerosols

Class III

• Designed for work with BSL 4 agents• Interchange box• Heavy duty rubber gloves• HEPA filtered on supply and exhaust (double or

incinerator)• Hard-ducted; dedicated exhaust 0.5 inches water

Page 35: Control of Bioaerosols

BAG-IN BAG-OUT (BIBO)

• Additional layer of protection

• Between BSC and BLDG exhaust

• HEPA• Required for BSL3/BSL4

laboratories

Page 36: Control of Bioaerosols
Page 37: Control of Bioaerosols

Respirators/PAPRs

Page 38: Control of Bioaerosols

Fit TestingBefore an employee uses any respirator with a negative or positive pressure tight-fitting facepiece, the employee must be fit tested with the same make, model, style, and size of respirator that will be used.

Page 39: Control of Bioaerosols

Qualitative Fit Test (QLFT)

A pass/fail fit test to assess the adequacy of respirator fit that relies on the individual’s response to the test agent.

Page 40: Control of Bioaerosols

Quantitative Fit Test (QNFT)An assessment of the adequacy of respirator fit by numerically measuring the amount of leakage into the respirator.