Content1.1 Fiber Optic Cable 1.1.1 Direct Buried 1.1.2 Aerial Duct 1.1.3 Aerial Tube 1.1.4 Aerial 1.1.5 Duct 1.1.6 12 & 24 Singlemode Indoor Breakout 1.1.7 Simplex Singlemode & Multimode 1.1.8 Duplex Singlemode & Multimode 1.1.9 Indoor Distribution

1.2 Fiber Optic Connector, Adapter, Passive Product & Accessories 1.2.1 Connector & Adapter 1.2.2 Coupler 1.2.3 Fix Attenuator 1.2.4 Fiber Hybric Adapter 1.2.5 Fiber Splice Protector Sleeve 1.2.6 Fiber Breakout Kit

1.3 Fiber Management System 1.3.0 Overview 1.3.1 Rack Mount FTDS 1.3.2 Rack Mount FTDC 1.3.3 Rack Mount FTDP 1.3.4 Rack Mount NGFM 1.3.5 Rack Mount RFPF 1.3.6 Rack Mount RFPP 1.3.7 Rack Mount TNB 1.3.8 Wall Mount WFP 1.3.9 Wall Mount WFPE 1.3.10 Wall Mount MFM 1.3.11 Fiber Closure 1.3.11.1 OFC-DR 1.3.11.2 OFC-DS 1.3.11.3 OFC-IB 1.3.11.4 OFC-IM-3 1.3.11.5 OFC-IM3 Re-entry Kit

1.4 Fiber Cable Assembly

456789

10111213

14151617181920

212224252627293031323335

3637383940

41

Page 3: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Content1.5 Fiber Test Equipment 1.5.1 FLS-100 Stabilized Laser Light Source 1.5.2 VFL-200 Visual Fault Locator 1.5.3 FPM-300 Optical Power Meter 1.5.4 LFT-400 Optical Talk Set 1.5.5 OFI-500 Optical Fiber Identifier

1.6 Fiber Converter 1.6.1 SM Fiber To Ethernet Converter 1.6.2 MM Fiber To Ethernet Converter 1.6.3 Multimode to Singlemode 1.6.4 Gigabit To Ethernet Converter 1.6.5 Fiber To RS-232/423/485 Converter 1.6.6 E1/T1, Datacom & Ethernet Multiplxer 1.6.7 Single E1/T1 To Fiber Converter

1.7 OPGW & ADSS ACCESSORIES 1.7.1 Overview 1.7.2 OPGW Closure

34567

10111213141516

1718

Page 4: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

1.1.1 Direct Buried1.1.2 Aerial Duct1.1.3 Armoured Duct1.1.4 Aerial Centre Tube1.1.5 Aerial1.1.6 Duct1.1.7 12 & 24 Singlemode Indoor Breakout1.1.8 Simplex Singlemode & Multimode1.1.9 Duplex Singlemode & Multimode1.1.10 Indoor Distribution1.1.11 Drop Cable

Fiber Optic Cable

Page 5: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Optical Fiber Cables

Simplex Assembly Cable Duplex Assembly Cable Indoor Distribution Cable

Indoor Breakout CableOutdoor All Dielectric Stranded Tubes Cable

Outdoor Aerial Stranded Tubes Cable

Outdoor Armoured Stranded Tubes Cable

Outdoor All Dielectric CentralTubes Cable

Outdoor Armoured CentralTubes Cable

LTOC-CB-XX-03 LTOC-CB-XX-04 LTOC-CB-XX05-YY

LTOC-CB-XX06-YY LTOC-CB-XX07-YY LTOC-CB-XX10-YY

LTOC-CB-XX08-YY LTOC-CB-XX07C-YY LTOC-CB-XX08C-YY

Page 6: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Optical Fiber CableDirect Buried

::: Cross Section Diagram :::

Cable Weight

Steel Wire Dia. /mm No. Dia. /mm No outer Dia.kg/km

LTOC-CB-DB-4xxx 4 2.3 2.2 1.0 2.2 5 1.0 2.0 15.5 250LTOC-CB-DB -6xxx 6 2.3 2.2 1.0 2.2 5 1.0 2.0 15.5 250LTOC-CB-DB -8xxx 8 2.3 2.2 1.0 2.2 5 1.0 2.0 15.5 250LTOC-CB-DB -12xxx 12 2.3 2.2 2.0 2.2 4 1.0 2.0 15.5 251LTOC-CB-DB -16xxx 16 2.3 2.2 2.0 2.2 4 1.0 2.0 15.5 252LTOC-CB-DB -18xxx 18 2.3 2.2 3.0 2.2 3 1.0 2.0 15.5 253LTOC-CB-DB -24xxx 24 2.3 2.2 3.0 2.2 3 1.0 2.0 15.5 253

Central Strength Member Loose Tube Inner Sheath

Thickness

Outer Sheath

ThicknessType Fiber Count

Ordering Information

Fillers

Transmission Parameters Of Fibres

G.652 G.652-C50/125 62.5/125

3.0 3.5<=0.36 <=0.36 1.0 1.5<=2.1 <=0.36 <=2.1<=0.22 <=0.22 <=0.22

<=0.25 <=0.25Chromatic dispersion

<=3.5 <=3.5<=18 <=18

1.0 to 6.04.5 to 11.2 \

MHz·km >=200 >=160>=500 >=500

ps/km1/2 <=0.2 <=0.2 <=0.1<=0.1 <=0.1 <=0.04

nm <=1260 <=1260 <=1480

G.652 G.655 G.65550/125 /125

1310 nm μm 9.2±0.4 9.2±0.41550 nm μm 10.4±0.8 10.4±0.8 9.2~10.0Mode field μm <=0.5 <=0.5 <=0.5noncircularityCore diameter μm 50±2 62.5±2Cladding diameter μm 125±1.0 125±2.0Cladding ellipticity % <=1 <=2Coating / cladding μm <=12concentricity

μmm

245±5>=4

Multimode FibreSinglemode Fibre

<=3.0μm <=0.5

Numerical aperture

Primary coating

Core / cladding

1288~1339 nm1550 nm

1530~1565 nm

Geometrical Parameters Of Fibres

1565~1625 nm

1300 nm

Bandwidth850 nm

ps/nm·km

individual fibrelink value

Parameter

Mode field diameter at wavelength

% <=1.0 <=2.0

concentricity

diameter

Curl

Unit

1310 nm1383 nm1550 nm

(in cable)Cut off wavelength

1625 nm

PMD

Parameter

Attenuation

Unit

850 nm

Multimode FibreSinglemode Fibre

dB/km

62.5

G.651 G.651G.655

G.651 G.651

ItemShort Term Long Term Short Term Long Term InstallingInstalled

Other MechanicalCharacteristicsInsulating Resistanceof SheathWater PenetrationMoisture Resistant

Jelly

Temperature

Bending Radius

Crush

Tensile

≥ 2000M after 24 hours water immersion

Correspond To IEC794-1-F5

+ 70, No jelly will be flooded

-40~+70 Additional dispersion 0.05dB/km

1000N/10cm

Correspond To IEC Publication

ParameterMechanical / Electrical / Environment Characteristics

30* Cable Diameter≥ 10* Cable Diameter

3000N1000N3000N/10cm

Structure and Material SpecificationCenter Strength Material Steel WireMember Diameter 2.3mm

Material PBTOut Dia 2.2mmMaterial Water Proof TapeThickness 0.2 mmMaterial AL/PE Tape

Tape 0.15mmEach Side PE 0.05mm

Material PEThickness 1.0mm

Armoured (2) Material PE Coated CorrugatedSteel Tape 0.15mmEach Side PE 0.05mm

Material PEThickness 2.0 mm

Inner Sheath

Thickness

Outer Sheath

Loose Tube

Wrap Tape

Armoured (1)Thickness

*Specification subject to change without prior notice

Fiber and Jelly

Loose Tube

CSM

Cable Core Jelly

Armouring (1)

Inner Sheath

Armouring (2)

Outer Sheath

Page 7: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Optical Fiber CableAerial

*Specification subject to change without prior notice

::: Cross Section Diagram :::

Message Wire

Neck

Cable Strength

Loose Tube

Fiber

Wrap Tape

Central Strength

Transmission Parameters Of Fibres

G.652 G.652-C50/125 62.5/125

3.0 3.5<=0.36 <=0.36 1.0 1.5<=2.1 <=0.36 <=2.1<=0.22 <=0.22 <=0.22

<=0.25 <=0.25Chromatic dispersion

<=3.5 <=3.5<=18 <=18

1.0 to 6.04.5 to 11.2 \

MHz·km >=200 >=160>=500 >=500

ps/km1/2 <=0.2 <=0.2 <=0.1<=0.1 <=0.1 <=0.04

nm <=1260 <=1260 <=1480

1288~1339 nm1550 nm

1530~1565 nm1565~1625 nm

1300 nm

Bandwidth850 nm

ps/nm·km

individual fibrelink value

1310 nm1383 nm1550 nm

(in cable)Cut off wavelength

1625 nm

PMD

Parameter

Attenuation

Unit

850 nm

Multimode FibreSinglemode Fibre

dB/km

G.651 G.651G.655

G.652 G.655 G.65550/125 /125

1310 nm μm 9.2±0.4 9.2±0.41550 nm μm 10.4±0.8 10.4±0.8 9.2~10.0Mode field μm <=0.5 <=0.5 <=0.5noncircularityCore diameter μm 50±2 62.5±2Cladding diameter μm 125±1.0 125±2.0Cladding ellipticity % <=1 <=2Coating / cladding μm <=12concentricity

μmm

245±5>=4

Multimode FibreSinglemode Fibre

<=3.0μm <=0.5

Numerical aperture

Primary coating

Core / cladding

Geometrical Parameters Of Fibres

Parameter

Mode field diameter at wavelength

% <=1.0 <=2.0

concentricity

diameter

Curl

Unit62.5

G.651 G.651

ItemShort Term Long Term Short Term Long Term InstallingInstalled

Other MechanicalCharacteristicsInsulating Resistanceof SheathWater PenetrationMoisture Resistant

Jelly

Temperature

Bending Radius

Crush

Tensile

≥ 2000M after 24 hours water immersion

Correspond To IEC794-1-F5

+ 70, No jelly will be flooded

-40~+70 Additional dispersion 0.05dB/km

300N

Correspond To IEC Publication

ParameterMechanical / Electrical / Environment Characteristics

30* Cable Diameter≥ 10* Cable Diameter

1500N600N

1000N

Message Wire MaterialSpec

Loose Tube Material Out Dia

Wrap Tape MaterialThickness

Structure and Material SpecificationSteel Wire1.4 x 7PBT1.9Water Blocking Tape0.2 mm

PE Coated Corrugated Tape Steel

Steel Tape 0.15Each Side PE 0.15

PE

MaterialArmoured

Outer Sheath Material

Thickness

Sheath Cable Weight

Steel Wire PE Sheath Dia. Dia. /mm No. Dia. /mm No. Thickness

mmOuter Dia. kg/km

LTOC-CB-A-4xxx 4 1.4 x 7 1.2 1.9 1 1.9 5 2.0 11.2 248LTOC-CB-A-6xxx 6 1.4 x 7 1.2 1.9 1 1.9 5 2.0 11.2 248LTOC-CB-A-8xxx 8 1.4 x 7 1.2 1.9 2 1.9 4 2.0 11.2 249LTOC-CB-A-12xxx 12 1.4 x 7 1.2 1.9 2 1.9 4 2.0 11.2 249LTOC-CB-A-16xxx 16 1.4 x 7 1.2 1.9 3 1.9 3 2.0 11.2 250LTOC-CB-A-18xxx 18 1.4 x 7 1.2 1.9 3 1.9 3 2.0 11.2 250LTOC-CB-A-24xxx 24 1.4 x 7 1.2 1.9 4 1.9 2 2.0 11.2 252

2.02.0

2.0 2.0 2.02.0

Message Wire

Steel Wire Dia.

2.0

Type Fiber Count

Ordering Information

FillersLoose TubeCentral Strength Member

Page 8: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Optical Fiber CableAerial Center Tube

*Specification subject to change without prior notice

::: Cross Section Diagram :::

Message Wire

Neck

Cable Sheath

Armour

Loose Tube

Wrap Tube

Fiber

Material Steel WireSpec 1.4 x 7

Material PBTOut Dia Refer table belowMaterial Water Proof TapeThickness 0.2 mmMaterial PE Coated

Corrugated Steel Tape

Thickness Steel Tape 0.15Each Side PE 0.15

Outer Sheath Material PE

Steel WireOuter

Dia./mm Kg/km

Message Wire

Loose Tube

Armoured

Correspond To IEC Publication

Bending Radius

Crush

Message Wire Cable

+ 70, No jelly will be flooded

2.0

≥ 2000M after 24 hours water immersion

4.24.2

Sheath

Thickness (mm)

2.02.02.02.02.02.0

1.2 1.2 1.2

Loose Tube

Dia. /mm

3.03.03.03.04.2

1.2 1.2 1.2 1.2

-40~+70 Additional dispersion 0.05dB/km

Type Fiber CountPE Sheath Dia.

Temperature

Tensile

Structure and Material Specification

Transmission Parameters Of Fibres

G.652 G.652-C G.655 G.651 G.65150/125 62.5/125

3.0 3.5<=0.36 <=0.36 1.0 1.5<=2.1 <=0.36 <=2.1<=0.22 <=0.22 <=0.22

<=0.25 <=0.25Chromatic dispersion

<=3.5 <=3.5<=18 <=18

1.0 to 6.04.5 to 11.2 \

MHz·km >=200 >=160>=500 >=500

ps/km1/2 <=0.2 <=0.2 <=0.1<=0.1 <=0.1 <=0.04

nm <=1260 <=1260 <=1480

dB/km

1288~1339 nm1550 nm

1530~1565 nm1565~1625 nm

1300 nm

Bandwidth850 nm

ps/nm·km

PMDindividual fibrelink value

(in cable)Cut off wavelength

1625 nm

Parameter

Attenuation

UnitMultimode FibreSinglemode Fibre

850 nm1310 nm1383 nm1550 nm

G.652 G.652-C G.655 G.651 G.65150/125 62.5/125

1310 nm m 9.2±0.4 9.2±0.41550 nm m 10.4±0.8 10.4±0.8 9.2~10.0

Mechanical / Electrical / Environment Characteristics

Mode field m <=0.5 <=0.5 <=0.5

Item Parameter

noncircularity

Short Term 3500N

Core diameter m 50±2 62.5±2

Long Term 1500N

Cladding diameter m

Short Term 1000N/10cm

Cladding ellipticity %

Long Term 300N/10cm

Coating / cladding m

Installing 30* Cable Diameter

concentricity

Installed ≥ 10* Cable DiameterOther MechanicalCharacteristicsInsulating Resistanceof Sheath

m

Water Penetration Correspond To IEC794-1-F5

m

Moisture Resistant

Jelly <=2.0

245±5>=4

<=125±1.0 <=125±2.0<=1 <=2

<=12

<=0.5 <=3.0m

Numerical aperture

Primary coating

Core / cladding

% <=1.0

Unit

Geometrical Parameters Of Fibres

concentricity

diameter

Curl

Parameter

Mode field diameter at wavelength

Multimode FibreSingelmode Fibre

LTOC-CB-ACT-4xxx 4 1.4X7 9.2 264LTOC-CB-ACT-6xxx 6 1.4X7 9.2 264LTOC-CB-ACT-8xxx 8 1.4X7 9.2 264LTOC-CB-ACT-12xxx 12 1.4X7 9.2 264LTOC-CB-ACT-16xxx 16 1.4X7 10.4 297LTOC-CB-ACT-18xxx 18 1.4X7 10.4 298LTOC-CB-ACT-24xxx 24 1.4X7 10.4 298

Wrap Tape

Page 9: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Optical Fiber CableArmoured Duct

Fiber and Jelly

Loose Tube

Wrap Tube

Inner Sheath

CSM

Cable Core Jelly

Outer Sheath

::: Cross Section Diagram :::

Ordering Information

Steel Wire Dia. No Dia/mm No Outer Dia. kg/kmLTOC-CB-AD -4xxx 4 2.0 1.0 1.9 5.0 2.0 11.2 117LTOC-CB-AD -6xxx 6 2.0 1.0 1.9 5.0 2.0 11.2 117LTOC-CB-AD -8xxx 8 2.0 2.0 1.9 4.0 2.0 11.2 118LTOC-CB-AD -12xxx 12 2.0 2.0 1.9 4.0 2.0 11.2 118LTOC-CB-AD -16xxx 16 2.0 3.0 1.9 3.0 2.0 11.2 119LTOC-CB-AD -18xxx 18LTOC-CB-AD -24xxx 24

LTOC-CB-AD -96xxx 96

2.0 3.0 1.9 3.0 2.0 11.2 1192.0 4.0 1.9 2.0 2.0 11.2 1211.9

Sheath Thickness

mm

Cable

1.9 1.9 1.9 1.9

LTOC-CB-AD -36xxx 36 2.0 6.0 - - 2.0 11.2 123LTOC-CB-AD -48xxx 48 2.3 6.0 - - 2.0 12.2 149

2.5 8.0 - - 2.0 14.2 1952.4

1.9 2.2

Dia/mm1.91.9

Type Fiber CountCentral Strength

Member Loose Tube Fillers

Material Steel WireDiameter 2.0mm

Material PBTOut Dia Refer table belowMaterial Water Proof TapeThickness 0.2 mm

AL/PE LaminatedTape Armoured & HDPE Outer Sheath

PE

2.0mm

Structure and Material Specification

Central StrengthMember

Loose Tube

Wrap Tape

Armoured Material

Outer SheathMaterial

Thickness

ItemShort Term Long Term Short Term Long Term InstallingInstalled

Other MechanicalCharacteristicsInsulating Resistanceof SheathWater PenetrationMoisture Resistant

Jelly

30* Cable Diameter≥ 10* Cable Diameter

300N/10cm

Correspond To IEC Publication

ParameterMechanical / Electrical / Environment Characteristics

1500N600N1000N/10cm

≥ 2000M after 24 hours water immersion

Correspond To IEC794-1-F5

+ 70, No jelly will be flooded

-40~+70 Additional dispersion 0.05dB/km

Temperature

Bending Radius

Crush

Tensile

Transmission Parameters Of Fibres

G.652 G.652-C50/125 62.5/125

3.0 3.5<=0.36 <=0.36 1.0 1.5<=2.1 <=0.36 <=2.1<=0.22 <=0.22 <=0.22

<=0.25 <=0.25Chromatic dispersion

<=3.5 <=3.5<=18 <=18

1.0 to 6.04.5 to 11.2 \

MHz·km >=200 >=160>=500 >=500

ps/km1/2 <=0.2 <=0.2 <=0.1<=0.1 <=0.1 <=0.04

nm <=1260 <=1260 <=1480

G.652 G.655 G.65550/125 /125

1310 nm μm 9.2±0.4 9.2±0.41550 nm μm 10.4±0.8 10.4±0.8 9.2~10.0Mode field μm <=0.5 <=0.5 <=0.5noncircularityCore diameter μm 50±2 62.5±2Cladding diameter μm 125±1.0 125±2.0Cladding ellipticity % <=1 <=2Coating / cladding μm <=12concentricity

μmm

245±5>=4

Multimode FibreSinglemode Fibre

<=3.0μm <=0.5

Numerical aperture

Primary coating

Core / cladding

1288~1339 nm1550 nm

1530~1565 nm

Geometrical Parameters Of Fibres

1565~1625 nm

1300 nm

Bandwidth850 nm

ps/nm·km

individual fibrelink value

Parameter

Mode field diameter at wavelength

% <=1.0 <=2.0

concentricity

diameter

Curl

Unit

1310 nm1383 nm1550 nm

(in cable)Cut off wavelength

1625 nm

PMD

Parameter

Attenuation

Unit

850 nm

Multimode FibreSinglemode Fibre

dB/km

62.5

G.651 G.651G.655

G.651 G.651

*Specification subject to change without prior notice

Page 10: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Optical Fiber CableDuct

*Specification subject to change without prior notice

::: Cross Section Diagram :::

Cable Weight

Dia. /mm No. Dia. /mm No. outer Dia. kg/kmLTOC-CB-D-4xxx 4 2.2 1.0 2.2 6 11.8 111LTOC-CB-D-6xxx 6 2.2 1.0 2.2 6 11.8 111LTOC-CB-D-8xxx 8 2.2 2.0 2.2 5 11.8 112LTOC-CB-D-12xxx 12 2.2 2.0 2.2 5 11.8 112LTOC-CB-D-16xxx 16 2.2 3.0 2.2 4 11.8 113LTOC-CB-D-18xxx 18 2.2 3.0 2.2 4 11.8 113LTOC-CB-D-24xxx 24 2.2 4.0 2.2 3 11.8 115

3.0

Type Fiber CountCentral Strength

Member

Ordering Information

FRP Dia.

Loose Tube

3.0 3.0 3.0

2.03.03.03.0

Fillers

2.0

Sheath

Thickness (mm)2.02.02.02.02.0

Fiber and Jelly

Loose Tube

Wrap Tube

CSM

Outer Sheath

1310 nm m 9.2±0.4 9.2±0.41550 nm m 10.4±0.8 10.4±0.8 9.2~10.0Mode field m <=0.5 <=0.5 <=0.5

Cladding diameter m 125±1.0 125±2.0Cladding ellipticity % <=1 <=2

Center Strength Material FRP Member Spec 3.0mmLoose Tube Material PBTP

Out Dia 2.2mm

Thickness 0.2 mm

Thickness Minimum 2.0

Mechanical / Electrical / Environment Characteristics

Long Term 600NCrush Short Term 1000N/10cm

Bending Radius Installing 30* Cable DiameterInstalled ≥ 10* Cable Diameter

Other Mechanical Correspond To IEC PublicationCharacteristicsInsulating Resistanceof SheathWater Penetration Correspond To IEC794-1-F5

Moisture Resistant + 70, No jelly will be flooded

Jelly

Temperature

Parameter

Structure and Material Specification

-40~+70 Additional dispersion 0.05dB/km

≥ 2000M after 24 hours water immersion

Armoured Material Kevlar

G.652 G.652-C G.655 G.651 G.651

Outer Sheath Material PE

50/125 62.5/125

Item

noncircularity

Tensile Short Term 1500N

Core diameter m 50±2 62.5±2

Long Term 300N/10cm

Coating / cladding concentricity

m 245±5m >=4

Multimode FibreSingelmode Fibre

m <=12

Parameter

Mode field diameter at wavelength

concentricity

diameter

Curl

<=2.0

Unit

Geometrical Parameters Of Fibres

<=0.5

Numerical aperture

Primary coating

Core / cladding

% <=1.0

<=3.0m

Transmission Parameters Of Fibres

G.652 G.652-C G.655 G.651 G.65150/125 62.5/125

3.5 3.5<=0.36 <=0.36 1.0 1.5<=2.1 <=0.36 <=2.1<=0.22 <=0.22 <=0.22

<=0.25 <=0.25Chromatic dispersion

<=3.5 <=3.5<=18 <=18

1.0 to 6.04.5 to 11.2 \

MHz·km >=200 >=160>=500 >=500

ps/km1/2 <=0.2 <=0.2 <=0.1<=0.1 <=0.1 <=0.04

nm <=1260 <=1260 <=1480

1383 nm1550 nm

Multimode FibreSinglemode FibreParameter

Attenuation

Unit

850 nm1310 nm

individual fibrelink value

(in cable)Cut off wavelength

850 nm

ps/nm·km

PMD

1625 nm

dB/km

1288~1339 nm1550 nm

1530~1565 nm1565~1625 nm

1300 nm

Bandwidth

Page 11: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Optical Fiber Cable12 & 24 Singlemode Inddor Breakout

*Specification subject to change without prior notice

::: Cross Section Diagram :::

up to 12 cords, on a single layer stranding > 12 and up to 24 cords or two layer stranding

Core Diameter 4 6 8 10 12 16 18 20 24

Cable Diameter ( mm)

Cable Mass ( kg /km ) 44 47 66 106 113 143 150

Max. Tensile - Loaded ( N )

- Unloaded

Min Bending Radius - Loaded

- Unloaded

Grush Resistance

Flex Resistance ( Cycles )

Fire Resistance

13.1

500

275

150

700

400

180

1000

600

200

Structured and Material Specification

1400

800

250

7.7 9.1 11.7

109

200N/10cm

Greater than 2000 Cycles

Compiles with UL 1666 and IEC 332 Parts 1 and 3C

100 25075 90

Transmission Parameters Of Fibres

G.652 G.652-C G.655 G.651 G.65150/125 62.5/125

3.0 3.5

<=0.36 <=0.36 1.0 1.5

<=2.1 <=0.36 <= 2.1 <=0.22 <=0.22 <=0.22

<=0.25 <=0.25Chromatic dispersion

<=3.5 <=3.5 <=18 <=18

1.0 to 6.04.5 to 11.2 \

>=200 >=160 >=500 >=500

<=0.2 <=0.2 <=0.1 <=0.1 <=0.1 <=0.04

G.652 G.652-C G.655 G.651 G.65150/125 62.5/125

1310 nm μm 9.2±0.4 9.2±0.4

1550 nm 10.4±0.8 10.4±0.8 9.2~10.0Mode field <=0.5 <=0.5 <=0.5noncircularity

Core diameter μm 50±2 62.5±2Cladding diameter μmCladding ellipticity %Coating / cladding

μmconcentricity

μmm

%

125±2.0

Primary coating

Core / cladding μm

Numerical apertureindividual fibre

dB/km

Unit

1288~1339 nm1550 nm

1530~1565 nm

Geometrical Parameters Of Fibres

1565~1625 nm

1300 nm

1625 nm

concentricity

diameter

Curl

Parameter

Mode field diameter at wavelength

ps/nm·km

PMD

Bandwidth

850 nm1310 nm1383 nm

link value

850 nm

Parameter

Attenuation

UnitMultimode FibreSinglemode Fibre

1550 nm

ps/km1/2

nm

MHz·km

(in cable)Cut off wavelength

<=3.0

<=1260 <=1260 <=1480

125±1.0

Multimode FibreSingelmode Fibre

<=1.0 <=2.0

245±5>=4

<=1 <=2

<=12

<=0.5

μm

μm

Part Number DescriptionLTOC-CB-SM06-12 Fiber Cable Breakout SM12 CoreLTOC-CB-SM06-24 Fiber Cable Breakout SM24 Core

::: Ordering Information :::

Page 12: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Optical Fiber CableSimplex Singlemode & Multimode

*Specification subject to change without prior notice

Outer Sheath

Peripheral Strength

Tight Buffer

Optical Fiber

Singlemode Multimode

Parameter ValueMaterial PVC/Nylon Installation

Diameter 0.9 ± 0.1 mm Maximum Pulling Load * 500 NMaterial Aramid Yarn Maximum Operating Load * 200 N

Assembly LongitudinallyCrush Resistance (between

parallel plates)400 N/cm

Outer Sheath Material * PVC Impact Resistance 20 times @ 1.5 NmThickness 0.5 ± 0.15 mm Minimum Bending Radius

Cable Diameter (Nominal) 3.0 ± 0.2 mm - During Installation 15 x Outer Diameter< 10 kg/km - Installed 10 x Outer Diameter

Temperature Range

- Storage on Reel -40ºC ~ +70ºC

- Operating -20ºC ~ +70ºC

Tigh Buffer

Peripheral Strength Member

Material Specification And Construction

Cable Weight (Nominal)

Part Number DescriptionLTOC-CB-SM-03 Fiber Cable Assembly SM Simplex 3.0mm

LTOC-CB-MM-03 Fiber Cable Assembly MM 62.5um Simplex 3.0mmLTOC-CB-MF-03 Fiber Cable Assembly MM 50um Simplex 3.0mm

::: Ordering Information :::

::: Cross Section Diagram :::

Transmission Parameters Of Fibres

G.652 G.652-C G.655 G.651 G.65150/125 62.5/125

3.0 3.5

<=0.36 <=0.36 1.0 1.5

<=2.1 <=0.36 <= 2.1 <=0.22 <=0.22 <=0.22

<=0.25 <=0.25Chromatic dispersion

<=3.5 <=3.5 <=18 <=18

1.0 to 6.04.5 to 11.2 \

>=200 >=160 >=500 >=500

<=0.2 <=0.2 <=0.1 <=0.1 <=0.1 <=0.04

G.652 G.652-C G.655 G.651 G.65150/125 62.5/125

1310 nm μm 9.2±0.4 9.2±0.4

1550 nm 10.4±0.8 10.4±0.8 9.2~10.0Mode field <=0.5 <=0.5 <=0.5noncircularity

Core diameter μm 50±2 62.5±2Cladding diameter μmCladding ellipticity %Coating / cladding

μmconcentricity

μmm

%

125±2.0

Primary coating

Core / cladding μm

Numerical apertureindividual fibre

dB/km

Unit

1288~1339 nm1550 nm

1530~1565 nm

Geometrical Parameters Of Fibres

1565~1625 nm

1300 nm

1625 nm

concentricity

diameter

Curl

Parameter

Mode field diameter at wavelength

ps/nm·km

PMD

Bandwidth

850 nm1310 nm1383 nm

link value

850 nm

Parameter

Attenuation

UnitMultimode FibreSinglemode Fibre

1550 nm

ps/km1/2

nm

MHz·km

(in cable)Cut off wavelength

<=3.0

<=1260 <=1260 <=1480

125±1.0

Multimode FibreSingelmode Fibre

<=1.0 <=2.0

245±5>=4

<=1 <=2

<=12

<=0.5

μm

μm

Page 13: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Optical Fiber CableDuplex Singlemode & Multimode

*Specification subject to change without prior notice

::: Cross Section Diagram :::

Outer Sheath

Peripheral Strength

Tight Buffer

Optical Fiber

9/125 um 50/125 um 62.5/125 um

8 ± 1.0 um 50 ± 3.0 um 62.5 ± 3.0 um125 ± 2 um 125 ± 2 um 125 ± 2 um

0.12 ± 0.01 0.20 ± 0.015 0.275 ± 0.015

1310 nm : <= 0.36 dB/km

1550 nm : <= 0.25 dB/km

1310 nm : <= 0.45 dB/km

1550 nm : <= 0.35 dB/km

850 nm : >= 300 MHz/km 850 nm : >= 150 MHz/km

1300 nm : >= 600MHz/km 1300 nm : >= 400MHz/km

GeCI4 (Germanium Tetrachloride ) + SiCI4 (Silica Tetrachloride)

SiCI4 (Silica Tetrachloride)

Fiber Core

Fiber Cladding

Bandwidth Not Applicable

850 nm : <= 3.0 dB/km

1300 nm : <= 1.0 dB/km

850 nm : <= 3.5 dB/km

1300 nm : <= 1.2 dB/km

Average Attenuation

Maximum Attenuation

Core Diameter

Cladding Diameter

Numerical Aperture

ValueParameterType Of Fiber

Parameter ValueMaterial PVC/Nylon Installation

Diameter 0.9 ± 0.1 mm Maximum Pulling Load * 300 N

Material Aramid Yarn Maximum Operating Load * 60 N

Assembly LongitudinallyCrush Resistance (between

parallel plates) 400 N/cm

Outer Sheath Material * PVC Impact Resistance 20 times @ 1.5 Nm

Thickness 0.5 ± 0.15 mm Minimum Bending Radius

Cable Diameter (Nominal) 5.8 ± 0.2 mm - During Installation 15 x Outer Diameter

< 20 kg/km - Installed 10 x Outer Diameter

Temperature Range

- Storage on Reel -40ºC ~ +70ºC

- Operating -20ºC ~ +70ºC

Tight Buffer

Peripheral Strength Member

Material Specification And Construction

Cable Weight (Nominal)

Part Number DescriptionLTOC-CB-SM-04 Fiber Cable Assembly SM Duplex 3.0mm

LTOC-CB-MM-04 Fiber Cable Assembly MM 62.5um Duplex 3.0mmLTOC-CB-MF-04 Fiber Cable Assembly MM 50um Duplex 3.0mm

::: Ordering Information :::

Singlemode Multimode

Page 14: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Optical Fiber CableArmoured Central Loose Tube

*Specification subject to change without prior notice

::: Cross Section Diagram :::

Cable Sheath

Armour

Loose Tube

Wrap Tube

Fiber

Strength member

Material Steel WireSpec 1.4mm

Material PBTOut Dia Refer table belowMaterial Water Proof TapeThickness 0.2 mmMaterial PE Coated

Corrugated Steel Tape

Thickness Steel Tape 0.15Each Side PE 0.15

Outer Sheath Material PE

Outer Dia./mm Kg/km

Strength member

Loose Tube

Wrap Tape

Armoured

≥ 15kv DC for 2 minutes after24 hours water immersion

Bending Radius

Crush

Cable

+ 70°C, No jelly will be flooded

Storage : -20°C ~ +60°C

≥ 2000M after 24 hours water immersion

SheathSteel Wire

1.41.41.41.4

Dia. /mm Thickness (mm)

3.02.02.02.0

Loose Tube

Dia. /mm

3.03.03.03.0

Type Fiber Count

Temperature

Tensile

Structure and Material Specification

Transmission Parameters Of Fibres

G.652 G.652-C G.655 G.651 G.65150/125 62.5/125

3.0 3.5<=0.36 <=0.36 1.0 1.5<=2.1 <=0.36 <=2.1<=0.22 <=0.22 <=0.22

<=0.25 <=0.25Chromatic dispersion

<=3.5 <=3.5<=18 <=18

1.0 to 6.04.5 to 11.2 \

MHz·km >=200 >=160>=500 >=500

ps/km1/2 <=0.2 <=0.2 <=0.1<=0.1 <=0.1 <=0.04

nm <=1260 <=1260 <=1480

dB/km

1288~1339 nm1550 nm

1530~1565 nm1565~1625 nm

1300 nm

Bandwidth850 nm

ps/nm·km

PMDindividual fibrelink value

(in cable)Cut off wavelength

1625 nm

Parameter

Attenuation

UnitMultimode FibreSinglemode Fibre

850 nm1310 nm1383 nm1550 nm

G.652 G.652-C G.655 G.651 G.65150/125 62.5/125

1310 nm m 9.2±0.4 9.2±0.41550 nm m 10.4±0.8 10.4±0.8 9.2~10.0

Mechanical / Electrical / Environment Characteristics

Mode field m <=0.5 <=0.5 <=0.5

Item Parameter

noncircularity

Short Term 1500N

Core diameter m 50±2 62.5±2

Long Term 600N

Cladding diameter m

Short Term 1000N/10cm

Cladding ellipticity %

Long Term 300N/10cm

Coating / cladding m

Installing 30* Cable Diameter

concentricity

Installed 10* Cable DiameterSpark Voltage ofSheathInsulating Resistanceof Sheath

m

Water Penetration Correspond To IEC794-3

m

Moisture Resistant Jelly <=2.0

245±5>=4

<=125±1.0 <=125±2.0<=1 <=2

<=12

<=0.5 <=3.0m

Numerical aperture

Primary coating

Core / cladding

% <=1.0

Unit

Geometrical Parameters Of Fibres

concentricity

diameter

Curl

Parameter

Mode field diameter at wavelength

Multimode FibreSingelmode Fibre

LTOC-CB-CT-4xxx 4 10.8 137LTOC-CB-CT-6xxx 6 10.8 137LTOC-CB-CT-8xxx 8 10.8 137LTOC-CB-CT-12xxx 12 10.8 137

Operation : -5°C ~ +40°COperation : -20°C ~ +60°C

Page 15: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Optical Fiber CableIndoor Distribution

*Specification subject to change without prior notice

::: Cross Section Diagram :::

Fiber

Tight Buffer

Kevlar

Outer Sheath

Fiber

Tight Buffer

Kevlar

Outer Sheath

Multimode

Singlemode

Material Short Term Long Term

LTOC-CB-4XXX 4 PVC 400 200LTOC-CB-6XXX 6 PVC 500 300LTOC-CB-8XXX 8 PVC 500 300LTOC-CB-10XXX 10 PVC 600 400LTOC-CB-12XXX 12 PVC 600 400

Outer Sheath

25.029.0

Max. Tension ForceCable

Weight (kg/km)

17.022.023.0

1.0 5.86.1

1.0 1.0 1.0 1.0

4.65.05.5

Type Fiber Count

Ordering Information

Thickness (mm) Outer Dia. (mm)

Mechanical / Electrical / Environment CharacteristicsItem

Tensile Short Term 600NLong Term 450N

Crush 200N/10cm

Bending Radius Installing 30* Cable DiameterInstalled ≥ 10* Cable Diameter

Other Mechanical Correspond to IEC Publication CharacteristicsInsulating Resistanceof SheathWater Penetration Correspond To IEC 794-1-F5Moisture Resistant + 70, No jelly will be flooded

Jelly

Parameter

-40~+70 Additional dispersion 0.05dB/km

≥ 2000M after 24 hours water immersion

Temperature

Diameter 0.9mmMaterial KEVLARMaterial PVCThickness 1.0mm

Sheath

Structure and Material SpecificationTight Buffered FibreArmoured Layer

Transmission Parameters Of Fibres

G.652 G.652-C G.655 G.651 G.65150/125 62.5/125

3.0 3.5 <=0.36 <=0.36 1.0 1.5 <=2.1 <=0.36 <= 2.1 <=0.22 <=0.22 <=0.22

<=0.25 <=0.25Chromatic dispersion

<=3.5 <=3.5 <=18 <=18

1.0 to 6.04.5 to 11.2 \

>=200 >=160 >=500 >=500

<=0.2 <=0.2 <=0.1 <=0.1 <=0.1 <=0.04

G.652 G.652-C G.655 G.651 G.65150/125 62.5/125

1310 nm μm 9.2±0.4 9.2±0.41550 nm 10.4±0.8 10.4±0.8 9.2~10.0Mode field <=0.5 <=0.5 <=0.5noncircularityCore diameter μm 50±2 62.5±2Cladding diameter μmCladding ellipticity %Coating / cladding μmconcentricity

μmm

%

125±2.0

Primary coating

Core / cladding μm

Numerical aperture

individual fibre

dB/km

Unit

1288~1339 nm1550 nm

1530~1565 nm

Geometrical Parameters Of Fibres

1565~1625 nm

1300 nm

1625 nm

concentricity

diameter

Curl

Parameter

Mode field diameter at wavelength

ps/nm·km

PMD

Bandwidth

850 nm1310 nm1383 nm

link desin value

850 nm

Parameter

Attenuation

UnitMultimode FibreSinglemode Fibre

1550 nm

ps/km1/2

nm

MHz·km

(in cable)Cut off wavelength

<=3.0

<=1260 <=1260 <=1480

125±1.0

Multimode FibreSingelmode Fibre

<=1.0 <=2.0

245±5>=4

<=1 <=2

<=12

<=0.5

μmμm

Page 16: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Optical Fiber CableDrop Cable

*Specification subject to change without prior notice

::: Cross Section Diagram :::

Material PBT or PC

Material Aramid Yarns

Outer Sheath Material PE

Short Term (N) Outer Dia./mm

WeightKg/km

Loose Tube

Correspond To IEC Publication

Bending Radius

Crush

Max Tension Force Cable

+ 70, No jelly will be flooded

≥ 2000M after 24 hours water immersion

200

100100

1000100 100100100

-40~+70 Additional dispersion 0.05dB/km

Type Fiber CountLong Term (N)

Temperature

Tensile

Structure and Material Specification

Transmission Parameters Of Fibres

G.652 G.652-C G.655 G.651 G.65150/125 62.5/125

3.0 3.5<=0.36 <=0.36 1.0 1.5<=2.1 <=0.36 <=2.1<=0.22 <=0.22 <=0.22

<=0.25 <=0.25Chromatic dispersion

<=3.5 <=3.5<=18 <=18

1.0 to 6.04.5 to 11.2 \

MHz·km >=200 >=160>=500 >=500

ps/km1/2 <=0.2 <=0.2 <=0.1<=0.1 <=0.1 <=0.04

nm <=1260 <=1260 <=1480

dB/km

1288~1339 nm1550 nm

1530~1565 nm1565~1625 nm

1300 nm

Bandwidth850 nm

ps/nm·km

PMDindividual fibrelink value

(in cable)Cut off wavelength

1625 nm

Parameter

Attenuation

UnitMultimode FibreSinglemode Fibre

850 nm1310 nm1383 nm1550 nm

G.652 G.652-C G.655 G.651 G.65150/125 62.5/125

1310 nm m 9.2±0.4 9.2±0.41550 nm m 10.4±0.8 10.4±0.8 9.2~10.0

Mechanical / Electrical / Environment Characteristics

Mode field m <=0.5 <=0.5 <=0.5

Item Parameter

noncircularity

Short Term 300N

Core diameter m 50±2 62.5±2

Long Term 100N

Cladding diameter m

Short Term 1000N/10cm

Cladding ellipticity %

Long Term 200N/10cm

Coating / cladding m

Installing 30* Cable Diameter

concentricity

Installed ≥ 10* Cable DiameterOther MechanicalCharacteristicsInsulating Resistanceof Sheath

m

Water Penetration Correspond To IEC794-1-F5

m

Moisture Resistant

Jelly <=2.0

245±5>=4

<=125±1.0 <=125±2.0<=1 <=2

<=12

<=0.5 <=3.0m

Numerical aperture

Primary coating

Core / cladding

% <=1.0

Unit

Geometrical Parameters Of Fibres

concentricity

diameter

Curl

Parameter

Mode field diameter at wavelength

Multimode FibreSingelmode Fibre

LTOC-CB-DRC-04 4LTOC-CB-DRC-02 2

300300

3.5 153.5 15

LTOC-CB-DRC-06 6 300 3.5 15LTOC-CB-DRC-08 8 300 3.5 16LTOC-CB-DRC-10 10 300 3.5 16LTOC-CB-DRC-12 12 300 3.5 16LTOC-CB-DRC-(14-24) 14-24 300 4.0 18

Strengthen Layer

Fiber & Jelly

Loose Tube

Strength Member

Outer Sheath

Max Crush

Short Term (N) Long Term (N)

20010002001000200100020010002001000

100 2001000

Page 17: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

1.2.1 Connector & Adapter1.2.2 Coupler1.2.3 Fix Attenuator1.2.4 Fiber Hybric Adapter1.2.5 Fiber Splice Protector Sleeve1.2.6 Fiber Breakout Kit1.2.7 Polarization Independent Circulator

Fiber Optic Connector,Adapter, Passive Product & Accessories

Page 18: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Connector

Fiber Optic Adapter

SC E-2000 FC SMA ST MU LC MTRJ DIN D4

SC E-2000 FC SMA ST MU LC MTRJ DIN

SC FC LC

Hybrid Adapter Bare Fiber Adapter

ST-SMA ST-SC FC-ST FC-SC FC-Din SMA FC STE-2000-FC

Fixed Attenuator Head Shrink Protection Sleeve

SingleRibbon

1x2 1x4

Optical Coupler / Splitter Optical Circulator

Fiber Optic Connectors,Adapters & Accessories

Page 19: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Connector & Adapter

::: Specification - Connector :::

::: Specification - Adapter :::

::: Ordering Information :::

LTOC - CON - - -

LTOC - ADP - - - -

Connector

Adapter

SM : SinglemodeMM : Multimode

SX : SimplexDX : Duplex

C : CeramicB : Bronze

01: 0.9mm02 : 3.0mm03 : 2.0mm

D : FlangeS : Square Flange

Min Typ Max

Insertion Loss (dB) 0.15 0.40Durability (dB) 1,000 matings 0.20Operating Temperature (dB) -40ºC~80ºC 0.20Humidity Cycling (dB) 75ºC, RH 95% 0.20

Vibration (dB) 10~55Hz (3 Axis) 0.20Impact 1.5m drop, 8 cycles 0.20

Characteristics ConditionsValue

Type Singlemode MultimodeInsertion Loss 0.3 dB 0.3 dBBack Reflection -50 dB -22 dBOperating Temperature -40ºC to +85ºC -40ºC to +85ºC

D4 : D4 LC : LCDIN : DI ST : STFC : FC MTRJ : MRFC/APC : FA SMA : MASC : SC E-2000 : E2SC/APC : SA E2000/APC : EA

FDDI : FD MU : MU

Connector & Adapter Type

Page 20: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Coupler

::: Singlemode Wavelength Independent Coupler :::

::: Specification :::

::: Features :::

Low excess loss Low insertion loss Available in wide range of coupling ratios Environment Stablity Comply to Bellcore's GR-1221 standards

Center Wavelength (nm) 1310 or 1550

Bandwidth (nm) ±40

Coupling Ratio (%) 1 ~ 50

Typical Excess Loss (dB) ≤0.15

Typical Insertion Loss (dB) ≤3.2

PDL (dB) ≤0.10

Min Directivity (dB) ≥60

Temperature (°C) ≤0.002

Operating Temperature (°C) -40 ~ +70

Storage Temperature (°C) -40 ~ +85

Max Operating Power (mW) 300

Max Tensile Strength (N) 5

Item Single-mode Dual-Windows Coupler Unit

Page 21: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Fixed Attenuator

Low backreflection High power endurance Precise control of attenuation range Easy installation

Fiber optic telecommunications LAN (Local Area Network) High speed transmissions system Bi-directional system

::: Specification :::

::: Features :::

::: Aplication :::

::: Ordering Information :::

ParameterOperating Wavelength Range

Attenuation ValueAttenuation Accuracy

Return Loss

PremiumWavelength Independance

± 0.5dB> 50dB

5, 10, 15, 20 dB

Operating Temperature -40ºC to ± 80ºC

Part NumberLTOC-ATT-FC-05/10/15/20LTOC-ATT-SC-05/10/15/20

DescriptionFiber Attenuator Fixed SM FC 5/10/15/20 dBFiber Attenuator Fixed SM SC 5/10/15/20 dB

LTOC-ATT-LC-05/10/15/20 Fiber Attenuator Fixed SM LC 5/10/15/20 dB

Page 22: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Hybrid Adapter

ST-SMA Hybrid Adapter E 2000 - FC Hybrid Adapter

FC-SC Hybrid Adapter ST-SC Hybrid Adapter

SMA Bare Adapter FC Bare Adapter

FC - Din Hybrid Adapter

FC-ST Hybrid Adapter

ST Bare Adapter

LTOC-ADP-STSMA LTOC-ADP-E2FC

LTOC-ADP-SCST

LTOC-ADP-FCDI

LTOC-ADP-FCSC LTOC-ADP-FCST

LTOC-ADP-SMA-SX-BR LTOC-ADP-ST-SX-BRLTOC-ADP-FC-SX-BR

Page 23: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Splice Protector Sleeve

::: Advantages :::

::: Ordering Information :::

Clear outer heatshrink materialLow temperature hot melt adhensive to encapsulate the spliceStainless steel rod for single fiber splices and a ceramic rod for ribbon fiber splices to ensureproper alignment and rigidity

Litech splice protector sleeves provide mechanical and environment protection for fusion splices ofsingle and ribbon fiber.

Part Number DescriptionLTCV-ACC-HS-40 Splice Protection Sleeve 40mmLTCV-ACC-HS-60 Splice Protection Sleeve 60mmLTCV-ACC-HS-RB Splice Protection Sleeve Ribbon

::: Specification :::Specification

Outer Tube Clear Heatshrink MaterialInner Tube EVA MaterialsInner Rod Stainless SteelShrinking Temperature 90~120 °CRadial Shrinking Rate >50%Axial Shrinking Rate < 3%Low Temperature Property No Crack-55°C lasting 4 hoursNormal Operation Temperature -40 ~ 65 °CNormal Operation Relative Humidity ≤ 90%Spack-over-Strength ≥ 20 kV/mmTensile Strength 20 Mpa

Page 24: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Breakout Kit

Fiber Breakout Kit (Blue - Big) Fiber Breakout Kit (Beige - Medium)

Fiber Breakout Kit (Black - Small) Fiber Tube

Fiber Breakout Kit (Yellow - Big)

LTOC-BOK-B-BLU LTOC-BOK-M-BEI

LTOC-BOK-S-BLK LTOC-BOK-OV-XX

LTOC-BOK-S-YEL-A

Fiber Breakout Kit (Yellow - Small)

LTOC-BOK-S-YEL-B

Page 25: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Polarization Independent Circulator

::: Features :::

::: Specification :::

Item/Model Type A Type B Wideband (5w)

Extra high isolationLow PDLPMD freeLow cross-talkLow insertion lossEnvironmentally stableEpoxy-free optical path

::: Applications :::

Optical amplifierOptical transmitterCATVTesting instrumentsBi-directional transmission systexDense WDMAdd/Drox Multiplexer (ADM)Dispersion compensation

Operating Wavelength ,nm 1470-1610ConfigurationsMinimum Isolation, dB 40(1530-1570nm) 35(1530-1570nm) 35(1470-1490nm)(at 25_C, all SOP) 40(1490-161-nm)Maximum Insertion Loss, dB 1.4(1470-1490)(at 0 ~ 60_C, all SOP) 1.3(1490-1500)

0.8(1530-1570nm) 1.0(1530-1570nm) 1.1(1500-1600)1.4(1600-1610)

Polarization dependent Loss, dBMaximum Optical Power, mW

Return Loss, dB (input/outpux)Polarization Mode Dispersion, ps

Operating Temperature, _CStorage temperature CDimension, mmNote: SOP = States of Polarization Optical laser signal through out Port 1→ 2 → 3Completeness Close off Port 2 → 1,3 → 2 Transmission

Port1→2→3

0-6045

Ø5 .5 × 60

≤0.15500≥50≤0.1

1310 or1550(±20)

Page 26: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

1.3.0 Overview1.3.1 Rack Mount FTDS1.3.2 Rack Mount FTDC1.3.3 Rack Mount FTDP1.3.4 Rack Mount MFM1.3.5 Rack Mount NGFM1.3.6 Rack Mount RFPF1.3.7 Rack Mount RFPP1.3.8 Rack Mount TNB1.3.9 Rack Mount WFP1.3.10 Rack Mount WFPE1.3.11 Rack Mount MFM1.3.12 Fiber Closure 1.3.12.1 OFC-DR 1.3.12.2 OFC-DS 1.3.12.3 OFC-IB 1.3.12.4 OFC-IM3 1.3.12.5 OFC-IM3 Re-entry Kit

Fiber Management System

Page 27: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

FTDS Fiber Management System

NGFM Fiber Management System

FTDC Fiber Management System

MFM Fiber Management System

FTDP Fiber Management System

Fiber Management System

LTOC-FTDC-XU-YP LTOC-FTDC-XU-YS

LTOC-FTDS-SPM LTOC-FTDS-SR LTOC-FTDS-CM

LTOC-NGFM-XU-Y

LTOC-NGFM-OD-96 LTOC-NGFM-OD-288 LTOC-NGFM-CAB

Splice / Patch Module

Swing Out Patch Module Pull Out Splice Module

LTOC-MFM-XU-YS LTOC-MFM-XU-YPPull Out Splice Module Swing Out Patch Module

LTOC-FTDP-XU-YS LTOC-FTDP-XU-YPPull Out Splice Module Pull Out Patch Module

Subrack Slack Cable Module

Fiber Outdoor Cabinet 96 Core Fiber Outdoor Cabinet 288 Core NGFM Fiber Cabinet

NGFM Splice & Patch Module

Page 28: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Management System

RFPF Fiber Distribution Panel(Fixed Type)

TNB Fiber Distribution Panel(Pull Out Type)

RFPP Fiber Distribution Panel(Pull Out Type)

RFPE Fiber Distribution Panel(Fixed Type)

RFPS Fiber Distribution Panel(Pull Out Type) FCP Compact Fiber Panel

WFP Wall Mount Fiber Distribution Box

WFPE Wall Mount Fiber Distribution Box

WFPS Wall Mount Fiber Distribution Box

LTOC-RFPF-XX-YY LTOC-RFPP-XX-YY LTOC-PN-TNB-XX

LTOC-RFPE-XX-YY LTOC-RFPS-XX-YY LTOC-FCP-XX-YY

LTOC-WFP-XX LTOC-WEPE-XX LTOC-WFPS-XX

Page 29: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Management System - FTDS

::: Fiber Termination & Distribution System (FTDS) :::

::: Splice / Patch Module :::

::: FTDS - Subrack :::

::: Slack Cable Drawer :::

Up to 12 connector per module - FC/PC, E2000/APC,SC/PC, ST/PCFibre guide are available to ensure the optical fibre bending radius is always greater than 30 mmThe module includes splice holder that holds up 12 splice sleevesStrength relief facilities for fibre cable

3U height FTDS SubrackThe standards subrack is 19" rack mount typeThe standards subrack shall be able to accomodateup to 10 splice & patch modules (Total of 120 fibre)Dust cover is available for each subrack (optional)

To store excess patchcord cablesSlide-Out designed for easy cable access

Page 30: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Management System - FTDC

::: FTDC Fiber Distribution Panel :::

Removeable front and rear door allow easy access to patch and fiber traysInterchangeable adapter plates accommodate various types of connectorsSwing out adpater panel design allow easy access to connectorIndividual slide out splice organizer trays provide easy access to splices for maintenanceStrength member clamp provides strain relief to avoid cable pull-out

Material : Aluminium with epoxy coatingFinish : High quality oven baked epoxy powderedColour : Beige

::: Features :::

::: Specification :::

::: Ordering Information :::

Part Number DescriptionLTOC-FTDC-2U-48S Fiber Rack Mount FTDC 2U 48C SpliceLTOC-FTDC-3U-48P Fiber Rack Mount FTDC 3U 48C PatchLTOC-FTDC-4U-72P Fiber Rack Mount FTDC 4U 72C PatchLTOC-FTDC-4U-96S Fiber Rack Mount FTDC 4U 96C SpliceLTOC-FTDC-5U-96P Fiber Rack Mount FTDC 5U 96C PatchLTOC-FTDC-5U-144S Fiber Rack Mount FTDC 5U 144C SpliceLTOC-FTDC-5U-144P Fiber Rack Mount FTDC 5U 144C Patch

Page 31: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Management System - FTDP

::: FTDP Fiber Distribution Panel :::

FTDP Fiber Distribution Panels are designed for terminating optical fiber in exchanges or communications room where higher density is required. FTDP features a modular system for fiber splicing and patching with flexible cablemanagement systems. A cost effective and easy installation solutions for fiber optic management system.

Material : Aluminium with epoxy coatingFinish : High quality oven baked epoxy powderedColour : Beige

::: Features :::

::: Specification :::

::: Ordering Information :::

Removeable front and rear door allow easy access to patch and fiber traysInterchangeable adapter plates accommodate various types of connectorsSlide out design allow easy access and reduce installation timeFlappable splice organizer trays provide easy access to splices for maintenanceStrength member clamp provides strain relief to avoid cable pull-out

Part Number DescriptionLTOC-FTDP-12/24 FTDP Splice & Patch FTDP 24 Core 133.4 x 431.8 x 304.8LTOC-FTDP-48S FTDP Splice FTDP 48 Core 133.4 x 431.8 x 304.8LTOC-FTDP-48P FTDP Patch FTDP 48 Core 177.8 x 431.8 x 304.8LTOC-FTDP-72S FTDP Splice FTDP 72 Core 133.4 x 431.8 x 304.8LTOC-FTDP-72P FTDP Patch FTDP 72 Core 177.8 x 431.8 x 304.8LTOC-FTDP-96S FTDP Splice FTDP 96 Core 177.8 x 431.8 x 304.8LTOC-FTDP-96P FTDP Patch FTDP 96 Core 222.2 x 431.8 x 304.8LTOC-FTDP-144S FTDP Splice FTDP 144 Core 266.7 x 431.8 x 304.8LTOC-FTDP-144P FTDP Patch FTDP 144 Core 311.1 x 431.8 x 304.8

Dimensions (HxWxD)

Page 32: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Management System - MFM

::: MFM Fiber Distribution Panel :::

::: Features :::

::: Specification :::

::: Ordering Information :::

Part Number DescriptionLTOC-MFM-72P MFM Patch Module 72 Core 203mm x 485mm x 258mm

203mm x 482mm x 258mm LTOC-MFM-144S MFM Splice Module 144 Core

Dimensions (HxWxD)

Material : Aluminium/mild steel with epoxy coatingFinish : High quality oven baked epoxy powderedColour : BeigeDimension : 203mm(H) x 485mm(W) x 258mm(D)

MFM Fiber Distribution Panels are designed for terminating optical fiber in exchanges or communications room where higher density is required. MFM features a modular system for fiber splicing and patching with flexible cablemanagement systems. MFM consists of a splice module and a patch module to provide a cost effective and easy installation solutions for fiber optic management system.

All front access allow easy access to patch and fiber traysInterchangeable adapter plates accommodate various types of connectorsSwing out adapter panel design of patch module allows easy access to the pigtail cable at the backSlide out splice module design allows access to fiber splice tray and reduce installation timeFlippable splice organizer trays provide easy access to splices for maintenanceStrength member clamp provides strain relief to avoid cable pull-out

Page 33: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Management System - NGFM

::: NGFM Fiber Management System :::

Total Fiber Management SystemsSpace for excess patch cablesHigh DensitySplice and patch in one trayCater for all connector typeIndividual slide out splice organizer trays provide easy access to splicesProper strain relief for incoming cablesGood appearance

NGFM Fiber Management System are designed for terminating optical fiber in exchanges or communicationsroom where higher density is required. NGFM features a modular system for splicing and patching with flexible cable management systems. All cable are front accessable with individual slide out splice organizer tray for easy fiber maintenance. A 46U NGFM is able to accomodate more than 600 splices and patch cables and is a cost effective solution for optic fiber management.

::: Advantages :::

::: Specification :::Dimension : Fiber Management Cabinet 46U x 300mm(D) x 900mm(W)Finish : High quality oven baked epoxy powderedColour : Beige

Page 34: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Management System - NGFM

::: NGFM Fiber Management System :::

::: Ordering Information :::

Fiber Outdoor Cabinet 96 CoreFiber Outdoor Cabinet 288 Core

NGFM Splice & Patch Sub Rack

NGFM Fiber Cabinet

Part Number DescriptionLTOC-NGFM-3U-48 Fiber Rack Mount NGFM 3U 48C Splice & PatchLTOC-NGFM-5U-96 Fiber Rack Mount NGFM 5U 96C Splice & PatchLTOC-NGFM-8U-144 Fiber Rack Mount NGFM 8U 144C Splice & PatchLTOC-NGFM-10U-192 Fiber Rack Mount NGFM 10U 192C Splice & PatchLTOC-NGFM-CAB NGFM Fiber CabinetLTOC-NGFM-OD-96 NGFM Outdoor Fiber cabinet 96 CoreLTOC-NGFM-OD-288 NGFM Outdoor Fiber cabinet 288 Core

Page 35: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Management System - RFPP

::: RFPP Fiber Distribution Panel (Pull Out Type) :::

RFPP Rack Mount Fiber Disribution Panels are design for terminating optical fiber in exchanges, communicationsrooms or in existing equipment racks where space is a constrain or higher density is required. FDP features a slideout design for effective installation and maintenance as well as front access patch panels for easy patching.

Dimensions : 435mm (W) x 44mm (H) x 315mm (D)Material : Mild steel with epoxy coatingFinish : High quality oven baked epoxy powderedColour : Light grey

::: Features :::

::: Specification :::

::: Ordering Information :::

LTOC-RFPP-24-E2 Fiber Rack Mount RFPP 1U Slide Out (E2000 x 24)LTOC-RFPP-24-SC Fiber Rack Mount RFPP 1U Slide Out 24 Port (SC Duplex)LTOC-RFPP-24-FC Fiber Rack Mount RFPP 1U Slide Out x 24 FCLTOC-RFPP-SN-1U Fiber Rack Mount RFPP 1U Slide Out 12 Core (Snap On)LTOC-RFPP-12-FC Fiber Rack Mount RFPP 1U Slide Out 12 Core FC

LTOC-RFPP-SN-2U Fiber Rack Mount RFPP 2U Slide Out 24 Core (Snap On)LTOC-RFPP-48-E2 Fiber Rack Mount RFPP 2U Slide Out 48 Core E2000

LTOC-RFPP-48-FC Fiber Rack Mount RFPP 2U Slide Out 48 Core FC

Part Number Description

Compact design for space savingFront access panel design for easy fiber patchingFlappable splice organizer trays provide easy access for maintenanceSide mounting bracket can be position in front or middle on 19" or 23" rackSlide out design for easy access during maintenance

Page 36: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Management System - RFPF

RFPF Fixed Type Fiber Distribution Panel provides an economical way of terminating small optical fiber countin communications room or existing equipment racks where space is a constrain.

Dimensions : 435mm (W) x 44mm (H) x 315mm (D)Material : Mild steel with epoxy coatingFinish : High quality oven baked epoxy powderedColour : Beige

::: Features :::

::: Specification :::

::: Ordering Information :::

Cost effectiveCompact design for space savingFront access panel design for easy fiber patchingSide mounting bracket can be position in front or middle on 19" or 23" rack

Part Number DescriptionLTOC-RFPF-SN-12 Fiber Rack Mount RFPF 1U Fixed (2 x 6 snap on)LTOC-RFPF-SN-16 Fiber Rack Mount RFPF 1U Fixed (2 x 8 snap on)

::: RFPF Fiber Distribution Panel (Fix Type) :::

Page 37: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Management System - WFP

::: WFP Wall Mount Fiber Distribution Box :::

WFP Wall Mount Fiber Distribution Boxes are used indoor to provide interconnection between active equipmentand outside plant cables in customer premises access for commercial and industrial telecommunicationapplication, or where space is constrained. WFP Series are designed for easy and efficient installation as well ashighest quality and appearance.

Double compartment designed separate carter splice from customer patchingDouble lockable and latchable door design provides security and protection for both spliced and patched fiber.Interchangeable adapter panel accomodate various types of connectorFlappable splice organizer trays provide easy access for maintenanceCable gland and strength member clamp provides strain relief to avoid cable pull out

Dimension : LTOC-WFP-12 : 350mm (W) x 285mm (H) x 45mm (D) LTOC-WFP-24 :350mm (W) x 285mm (H) x 70mm (D) LTOC-WFP-48 :350mm (W) x 285mm (H) x 140mm (D)Material : Mild steel with epoxy coatingFinish : High quality oven baked epoxy powdered Colour : Beige

::: Features :::

::: Specification :::

::: Ordering Information :::

Part Number DescriptionLTOC-WFP-12 Fiber Wall Mount WFP Distribution Box 12 CoreLTOC-WFP-24 Fiber Wall Mount WFP Distribution Box 24 CoreLTOC-WFP-48 Fiber Wall Mount WFP Distribution Box 48 Core

Page 38: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Management System - WFPE

::: WFPE Wall Mount Fiber Distribution Box - 6 port:::

WFPE Wall Mount Fiber Distribution Boxes are used indoor to provide interconnection or termination of multimodeand singlemode fibers. These cost effective distribution boxes are perfect for direct termination in telecommunicationcloset and where spaces is constrained.

Dimensiong : 270mm (W) x 170mm (H) x 45mm (D)Material : Mild steel with epoxy coatingFinish : High quality oven baked epoxy powdered

Cost effectiveCompact sizeInterchangeable adapter plate accommodate various types of connectorsDouble hinged and lock door for securityCable tie down bracket provide strain relief to avoid cable pull out

::: Features :::

::: Specification :::

::: Ordering Information :::Part Number Description

LTOC-WFPE-6 Fiber Wall Mount WFPE Distribution Box 6 Core

Page 39: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Management System - WFPE

::: WFPE Wall Mount Fiber Distribution Box - 12 port :::

WFPE Wall Mount Fiber Distribution Boxes are used indoor to provide interconnection or termination of multimodeand singlemode fibers. These cost effective distribution boxes are perfect for direct termination in telecommunicationcloset and where spaces is constrained.

Dimensiong : 305mm (W) x 235mm (H) x 76mm (D)Material : Mild steel with epoxy coatingFinish : High quality oven baked epoxy powdered

Cost effectiveCompact sizeInterchangeable adapter plate accommodate various types of connectorsDouble hinged and lock door for securityCable tie down bracket provide strain relief to avoid cable pull out

::: Features :::

::: Specification :::

::: Ordering Information :::Part Number Description

LTOC-WFPE-12 Fiber Wall Mount WFPE Distribution Box 12 CoreLTOC-WFPE-24 Fiber Wall Mount WFPE Distribution Box 24 CoreLTOC-WFPE-48 Fiber Wall Mount WFPE Distribution Box 48 Core

Page 40: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Management System - TNB

::: TNB Fiber Distribution Panel (Pull Out Type) :::

TNB Rack Mount Fiber Disribution Panels are design for terminating optical fiber in exchanges, communicationsrooms or in existing equipment racks where space is a constrain or higher density is required. FDP features a slideout design for effective installation and maintenance.

Dimensions : 490mm (W) x 88mm (H) x 360mm (D)Material : Mild steel with epoxy coatingFinish : High quality oven baked epoxy powdered Colour : Beige color

::: Features :::

::: Specification :::

::: Ordering Information :::

Compact design for space savingFront access panel design for easy fiber patchingFlappable splice organizer trays provide easy access for maintenanceSlide out design reduce time during maintenance

Part Number DescriptionLTOC-PN-TNB-24FC Fiber Rack Mount TNB Panel 2U 24C LTOC-PN-TNB-36FC Fiber Rack Mount TNB Panel 2U 36C

Page 41: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Closure - OFC-DR

"O" ring. 2 part clamp and bolt sealing design, no re-entry tape or sleeve required during re-access. Save costNo loose part - easy of installationMechanical cable sealing system for cable entry, without use of heat shrink tubingAccomodate extensive range of cable sizeMultiple drop cable ports for ready access Mountable in manhole, on wall and poleSecurity Locking DeviceNo special training and tooling requierdVarious dome size available

- Dimensions : S - 440mm (L) x 210mm (O.D) L - 480mm (L) x 250mm (O.D)- Colour : Black

F t::: Features :::

::: OFC-DR Optical Dome Closure ::::: OFC-DR Optical Dome Closure :::

::: Specification :::

OFC-DR Optical Dome Closure are designed for easy assembly and re-entry in the external plant installation.The closure featured a mechanical cable sealing system which made re-entry at no cost. The waterproofand rugged construction makes these closures perfect for the extreme plant environment.

::: Ordering Information :::Part Number Description

LTOC-OFC-DR-12A Optical Fiber Dome Closure OFC-DR 12 coreLTOC-OFC-DR-24A Optical Fiber Dome Closure OFC-DR 24 coreLTOC-OFC-DR-36A Optical Fiber Dome Closure OFC-DR 36 coreLTOC-OFC-DR-48A Optical Fiber Dome Closure OFC-DR 48 core

LTOC-OFC-DR-72A Optical Fiber Dome Closure OFC-DR 72 coreLTOC-OFC-DR-96B Optical Fiber Dome Closure OFC-DR 96 core

LTOC-OFC-DR-120B Optical Fiber Dome Closure OFC-DR 120 coreLTOC-OFC-DR-144B Optical Fiber Dome Closure OFC-DR 144 core

Page 42: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Closure - OFC-DS

::: OFC-DS Optical Dome Closure ::::: OFC-DS Optical Dome Closure :::

- Dimensions : S - 470mm (L) x 120mm (O.D)- Materail : Co-Polymer Polyproplylene- Colour : Black

::: Features :::

::: Specification :::

::: Ordering Information :::

OFC Optical Closure are designed for easy assembly and re-entry in the external plant installation.The waterproof and rugged construction makes these closures perfect for the extreme plant environment.

"O" ring. 2 part clamp and bolt sealing design, no re-entry tape or sleeve required during re-access. Save costNo loose part - easy of installationCable entry ports are sealed to cable by the use of unique mechanical clamp on system Mountable in manhole, on wall and poleNo special training and tooling requierdVarious dome size available

Part Number DescriptionLTOC-OFC-DS-12 Optical Dome Closure OFC-DS 12 coreLTOC-OFC-DS-24 Optical Dome Closure OFC-DS 24 coreLTOC-OFC-DS-36 Optical Dome Closure OFC-DS 36 coreLTOC-OFC-DS-48 Optical Dome Closure OFC-DS 48 coreLTOC-OFC-DS-72 Optical Dome Closure OFC-DS 72 core

Page 43: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Closure - OFC-IB

::: OFC-IB Optical Dome Closure ::::: OFC-IB Optical Dome Closure :::

2 Part stainless steel strap locking design, no re-entry tape required during re-access. Save costNo loose parts - ease of installationCable entry ports are sealed to cable size by the use of sealing tapeMountable in manhole, on wall and poleNo special training and tooling requiredVarious size available

- Dimensions : OFC-IB - 430mm (L) x 180mm (W) x 170mm (H) : - 380mm (L) x 155mm (W) x 155mm (H)- Materail : Co-Polymer Polyproplylene

::: Features :::

::: Specification :::

::: Ordering Information :::

OFI Inline Optical Closure features a fully mechanical system makes assembly and re-entry easy.The waterproofand rugged construction are desinged for the extreme plant environment.

Part Number DescriptionLTOC-OFC-IB-48C Fiber Closure Inline OFB-IB-48 CoreLTOC-OFC-IB-96C Fiber Closure Inline OFB-IB-96 Core

Page 44: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Closure - OFC-IM3

::: OFC-IM-3 Optical Dome Closure ::::: OFC-IM-3 Optical Dome Closure :::

::: Features :::

Litech Optical Inline Closures is designed for used in external plant environment. The waterproof and ruggedconstruction makes these closure perfect for underground, aerial and pedestal applications. The closures features full mechanical systems for easy assembly and easy to re-enter.OFC-IM-3A is designed to accommodate up to 48 fibers where as OFC-IM-3B is designed to accommodate upto 192 fibers.

Manufactured with engineering plastic for external used No loose parts - ease of installation Double strain relief for cables Mountable in manhole, on wall and aerial No special training and tooling required Various size available Pressurized valve for flash test

::: Specification :::OFC-IM-3A

ax Cable Diameter 25mm 25mmM

OFC-IM-3BSpecification (mm)

Min Cable Diameter 10mm 10mm

Closure Length 583mm 660mm186mm 222mmClosure Width

Closure Height 116mm 197mmUseable Length 387.5mm 406mmUseable Width 126mm 140mmUseable Heigth 76mm 89mm

::: Ordering Information :::Description

LTOC-OFC-IM3A-12 Fiber Closure Inline OFC-IM3A-12LTOC-OFC-IM3A-24 Fiber Closure Inline OFC-IM3A-24LTOC-OFC-IM3A-36 Fiber Closure Inline OFC-IM3A-36LTOC-OFC-IM3A-48 Fiber Closure Inline OFC-IM3A-48

Part Number

Page 45: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Optical Fiber ClosureOFC-IM-3-Re-entry Kit

::: Inline Closure Re-entry Kit :::

Excellent sealing to metal, rubber and cable jacket materialsSilent chemical resistanceMoldable and conformable for irregular surfaceExcellent weather and moisture protection for used in outdoor

Sealing Washer 8 pcsSealing Tape 2 rollsSealing Cord 2 stripsHose Clamp 2 pcsDummy Plug 2 pcsCable Tie 8 pcs

::: Features :::

::: Specification :::

::: Ordering Information :::

Part Number Description

OFC-RNTY-01A Closure Reentry Kit For Up To 48 FiberOFC-RNTY-01B Closure Reentry Kit For Up To 96 to 192 Fiber

Page 46: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

1.4.1 Optical Cable Assemblies

Fiber Cable Assembly

Page 47: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Optical Cable Assemblies

Pigtail Simplex Patchcord

Duplex Patchcord Distribution Patch Cable

Breakout Patch Cable Outdoor Patch Cable

Page 48: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Optical Cable Assemblies

::: Application :::

::: Specification :::

::: Ordering Information :::

Telecommunication networkCATV systemLocal Area Network

LTOC - - -

Min Typ MaxInsertion Loss (dB) 0.15 0.40

Return Loss (dB) Singlemode 0º 50

Singlemode 8º 60Multimode 40

Durability (dB) 1,000 matings 0.20Operating Temperature (dB) -40ºC~80ºC 0.20

Humidity Cycling (dB) 75ºC, RH 95% 0.20

Vibration (dB) 10~55Hz (3 Axis) 0.20

Impact 1.5m drop, 8 cycles 0.20

ValueCharacteristics Conditions

D4 : D4 LC : LC

DIN : DI ST : STFC : FC MTRJ : MR

FC/APC : FA SMA : MA

SC : SC E-2000 : E2SC/APC : SA E2000/APC : EAFDDI : FD MU : MU

Connector Type ( 1st & 2nd Connector )

01 : 250um 04 : Duplex02 : 900um 05 : Distribution03 : Simplex 06 : Breakout

Type Of Cable

Type Of FiberSM : Singlemode

MM : Multimode 62.5umMF : Multimode 50um

Cable LengthAny customized length

i.e : 3 : 3.0 mtrs ; 10 : 10.0 mtrs

Page 49: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

1.5.1 FLS-100 Stablized Laser Light Source1.5.2 VFL-200 Visual Fault Locator1.5.3 FPM-300 Optical Power Meter1.5.4 LFT-400 Optical Talk Set1.5.5 OFI-500 Optical Fiber Identifier1.5.6 OFA-600 Variable Optical Attenuator

Fiber Test Equipment

Page 50: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Test Equipment

FLS-100 Stabilized Laser Light Source VFL-200 Visual Fault Locator

FPM-300 Optical Power Meter LFT-400 Optical Talk Set

OFI-500 Optical Fiber Identifier OFA-600 Variable Optical Attenuator

FLS-100 VFL-200

FPM-300 LFT-400

OFI-500 OFA-600

Page 51: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Test Equipment

::: FLS-100 Stabilized Laser Light Source :::

::: Features :::

The FLS-100 series light source is a simple but versatile. FLS-100 are prefect for use in fiber testing : splicing, connector loss, cable acceptance, fiber attenuation, and other LAN, FDDI, and ISDN network. The straight forwards control panel is easy to use. Coupler with FPM-300 power meters, it is ideal for fiber end to end testing.

Portable and easy to useCW and 2KHz modulationIdeal for single-mode fiber testingBuild-in rechargeable battery pack and battery lowindicatorLCD display emitter power level and wavelengthDual wavelength outputPerfect for field Telecom, SONET, and CATV field works

::: Specification :::

Item/Model FLS-100

Output Power via 9/125mEmitter

-7/-6Laser Diode

Wavelength range (nm) 1310/1500 ± 20

Modulation CW, 1Hz, 21Hz, 2701Hz, 1000Hz, 2000HzStability (20°C 15min) ± 0.05db

-10~+60Working Temperature (°C)-25~+70Storage Temperature (°C)

18Battery Operating Time (mins)Dimensions (mm) 180 x 90 x 36.5

300Weight (g)Power Supply (battert rechargeable) + power supply adapter

Fiber Connector FC

Page 52: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Test Equipment

Litech Visual Fault Locator Pen is equipped with a 650mm high power visible diode, can be operated in CW (continuous) or MOD (1Hz modulation) mode. Visual Fault Locator Pen is housed in a pocket-size, rugged brass casing, and comes with a carrying case.

::: Features :::For locating broken points in fibersEquipped with a 650-nm visible laser diodeCan be operated in continuous or pulse modes for clear noticeable resultsOne green LED indicator shows the operating modePower switch on the end for battery on/offPush button operates CW / Mod. (2.5 Hz frequency) / pauseClip pocket-size pen designProtective cap for extra protection

::: Specification :::

Model Number VFL-200

Power supply two 1.5V AA Alkaline batteries(Do not use rechargeable type)

Dimension & Weight Length : 170mm(w/batteries) Diameter : 13.5mm

Approx. weight : 88mg

Connector Universal

Light source Class 3A Laser diodeCentral Wavelength 650nm + 10nm

Spectral width (FWHM) < 10nm

1mW Into SMF-28 single mode fiber

Transmision CW mode or 2.5 Hz modulated

Environment

Operation -10oC to +50

oC, 0 to 95% RH (non-condensing)

-20oC to +80

oC, 0 to 95% RH (non-condensing)Storage

Power (on/off )

Control Button

Push 1 Time : bind lightPush 2 Time : glittlePush 3 Time : power off

::: VFL-200 Visual Fault Locator :::

Page 53: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Test Equipment

::: Features :::

Compact design and portableLarge LCD display screenResolution to 0.01dB; accuracy to ± 5%Measurement units in dB, dBm, mW and nWSelections of relative/absolute powersDeal for both multi-mode and single-mode optical fibersBuild-in rechargeable battery packBaterry-low indicatorsCalibrated at 850nm, 980nm, 1310nm,1500nmDeal for LAN, ISDN, FDDI, Telecom, SONET and CATV

::: Specification :::

The FPM-300 series is a range of optical power meter covering spectral range from 800nm to 1600nm ; idealfor both single-mode and multi-mode fiber testing. FPM-300 optical power meter is light weight and easyto use.

FPM-301 FPM-303 FPM-304Item/Model FPM-302

Sensor Type InGaAsWavelength range (nm) 800~1600

Dynamic Range (dBm) -70~ +3 -60~ +10 -30~ +20 -20~ +30Accuracy (dB) ± 0.25Resolution 0.01dB

-10~+60Working Temperature (°C)-25~+70Storage Temperature (°C)

Auto Off Time (mins) 1028Battery Operating Time (mins)

Dimensions (mm) 150 x 74 x 25

250Weight (g)Power Supply 8.4V (battert rechargeable) + power supply adapter

::: FPM-300 Optical Power Meter :::

Page 54: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Test Equipment

::: Features :::

LFT-400 designed for communication on-site by transmitting voice into modulated optical signal through the fiber link, with high voice quality.

Full duplex communication via a SM fiberLarge LCD ScreenSeven color backlightAdjustable headset volumeDigital communication with minimized line noiseLow power Alam

::: Specification :::

* dBr : measurement value (in dB) against a " reference" which is the light source itself

Item/Model LFT-400Communication Full DuplexCentral Wavelength 1310/1500 ± 20 nmFWHM <=5nmEmitter Laser DiodeTransmission Distance <=80 KmDynamic Range 40dB (9 / 125 mm)Output Power 3-4.5dB or 2KHz, 500 modulatorOutput Stability (typ.)*3 ± 0.1dB / ± 0.25dB (1/8 Hrs.)TemperatureFiber Connector

± 0.02 dBm / ºC FC

Operating Time 5hrs (Continuous)

::: LFT-400 Optical Talk Set :::

Page 55: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Test Equipment

::: OFI-500 Optical Fiber Identifier :::

::: Features :::Easy and convenient operation with a single keystrokeDetecting three signal frequencies 2kHz, 1kHz, 270HzDisplaying signal in intensityConcise LED lightLow battery reminder Two 1.5V dry batteries (Mignon AA size)Interchangeable adapter heads (clamps) for bare and jacketed fiber

::: Specification :::

Model Number OFI 500

Wavelength Range

Detector Type InGaAa 2pcs

Recognizable signal Type CW, 270Hz ± 10%, 1KHz ± 10%, 2kHz ± 10%

-55dBmDetecting Sensitivity

Clamp Type HO. 25 bare fiber H0.9/H2.5/H3.0 jacheted fiber

Signal Frequency 270Hz, 1kHz, 2kHz LED

Signal Traffic Left or right LED

5 grades LEDSignal Intensity

Low Battery LED

-10°C ~ +60°COperating Temperature (°C)

Storage Temperature (°C -25°C ~ +70°C

Dimentions 200mm x 80mm x 40mm

Battery Operating Time (h) 8h

1.5V AA batteries *2pcsPower Supply

Weight 200g

650nm ± 10mm

Page 56: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Test Equipment

::: OFA-600 Valiable Optical Attenuator

::: Features :::Large LCD screen +/- 0.1dB attenuation resolution0-60dB variable attenuation range> 50dB return loss0.1db, 1db and 10db attenuation step selectionInterchangeable adapter interface

::: Specification :::

Model Number OFA-600-50D OFA-600-60DWavelength

Accuracy ≤ ± 0.1dB (0db ~20dB)

≤ ± 0.2dB (20db ~50dB)

Resolution

Insertion Loss < 0.15 dB

Return Loss

Attenuation Repetition

> 60dB(PC), >50db(PC)

0.05 dB

Fiber Type SMF 3/125μ

FC (Standard), ST, SC, (Optional)Optical Adapter

1310nm/1550nm

≤ ± 0.1dB (0db ~20dB)

Attenuation Range 0~ -50dB (without insertion Loss) 0~ -60dB (without insertion Loss)

≤ ± 0.2dB (20db ~60dB)

0.1 dB

1310nm/1550nm

Litech OFA-600 variable optical attenuator is designed for singlemode application at 1310nm and 1550nm. OFA variable optical attenuator allow variable attenuation setting from 0 to 60dB. This handheld variable attenuator is designed for system testing and acceptance, optical margin analysis, system loss simulation or power meter calibration. A perfect tool for field, manufacturing or R&D applications.

Working Time > 10 hours ( 8.4V/NI-cd battery)Baterry lifetime

14.0 x 7.8 x 3.8cm (without Holster) ,17.3 x 9.0 x 4.2cm (with Holster)Dimension

450gWeight

-5 ~ +60°COperation Temperature

Storage Temperature -25 ~ +70°C

Page 57: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

1.6.1 SM Fiber To Ethernet Converter1.6.2 MM Fiber To Ethernet Converter1.6.3 Multimode To Singlemode1.6.4 Gigabit To Ethernet Converter1.6.5 Fiber To RS-232/423/485 Converter1.6.6 E1/T1, Datacom & Ethernet Multiplexer1.6.7 Single E1/T1 To Fiber Converter

Fiber Converter

Page 58: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Converter

Singlemode Fiber to Ethernet Converter Multimode Fiber to Ethernet Converter

Multimode to Singlemode Converter Gigabit to Ethernet Converter

Fiber to RS-232-422-485 Converter Single Fiber to E1-T1 Converter

LTCV-100S-SC-XX LTCV-10/100S-SS-XX

LTCV-SMMM-SC-XX LTCV-1000S-SC-XX

LTCV-MM232-ST LTCV-ESM-01

Page 59: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Converter

::: 10/100 Base-TX to 10/100 Base-FX Fiber SC/ST Converter (Singlemode) :::

::: Features :::

The Fast Fiber Converter FIB-10/100M/ST and FIB-10/100M/SC provides you with ST and SC connector for your fiber opticcable and RJ-45 ports (straight through and crossover) for your 10/100 Base-TX twisted pair cable connection.Ultilizing singlemode optical cable, the cabling distance of your 100Base-TXnetwork may be extended to 15, 30 or 50kilometers. When auto-negeotiation is selected, these units will automatically tailor themselves to convert both half-duplex and full duplex signals, depending on your specific network needs. You may also set the unit to convert signalsin full-duplex or half duplex only.Five LED indicators signal the power status of the converter, RJ-45 port and FX portactivity, and full or half duplex status

::: Specification :::

::: Ordering Information :::

Complies with IEEE 802.3u 10/100 Base-FX and 10/100 Base-TX standardsFiber connectivity models for 15, 30 or 50KMST or SC connector accomodates singlemode fiber size 9/125umTwo RJ-45 for straight or cross-over connectionFull duplex, Half duplex or auto selectable5 diagnostic LEDs

Part Number DescriptionFIB-10/100S/ST(SC) 15 10/100 Base-TX to Fiber Converter, Singlemode, ST(SC) Type, 15KmFIB-10/100S/ST(SC) 30 10/100 Base-TX to Fiber Converter, Singlemode, ST(SC) Type, 30KmFIB-10/100S/ST(SC) 50 10/100 Base-TX to Fiber Converter, Singlemode, ST(SC) Type, 50KmFIB-10/100S/ST(SC) 120 10/100 Base-TX to Fiber Converter, Singlemode, ST(SC) Type, 120Km

CompatibilityStandards IEEE 802.3u 10/100 Base-TX and 10/100 Base-FXProtocol CSMA/CD

Physical CharacteristicsInterface ST or SC connector, using 9/125um singlemode fiber optic cable RJ-45 connector, using UTP 100 ohm Cat 5 or above cableMaximum Segment Length UTP cable (10/100 Base-FX) : 100 meters singlemode cable, full duplex: 15, 30 or 50 KilometersTemperature 0ºC to 70ºC (Operating)Humidity 10% to 90% (Non-condensing)External Power Supply Input Rating : 110 or 220 VAC, 50-60Hz Output Rating : 9VDC, 800mA

Page 60: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Converter

::: Features :::

The Fast Fiber Converter Multimode Series FIB-10/100M/ST and FIB-10/100M/SC provides you with ST or SC connectorfor your fiber optic cable and RJ-45 ports (straight through and crossover) for your 10/100 Base-TX cable connectionrepectively. When auto-negeotiation is selected, these units will automatically tailor themselves to convert both half-duplex and full duplex signals, depending on your specific network needs. You may also set the unit to convert signalsin full-duplex or half duplex only. The Fast Fiber Converter give you the freedom to extend your 10/100 Mpbs cablingdistance by allowing connectivity up to 2KM. Five LED indicators signal the power status of the converter, RJ-45 portand FX port activity, and full or half duplex status

Complies with IEEE 802.3u 10/100 Base-FX and 10/100 Base-TX standardsFiber connectivity up to 2KmST or SC connector accomodates multimode fiber optic cable size 62.5/125umTwo RJ-45 for straight or cross-over connectionFull duplex, Half duplex or auto selectable5 diagnostic LEDs

::: Specification :::

::: Ordering InformationPart Number Description

LTCV-TPMM-ST-2 10/100 Base-TX to Fiber Converter, Multimode, ST Type, 2KmLTCV-TPMM-SC-2 10/100 Base-TX to Fiber Converter, Multimode, SC Type, 2Km

CompatibilityStandards IEEE 802.3u 10/100 Base-TX and 10/100 Base-FXProtocol CSMA/CD

Physical CharacteristicsInterface ST or SC fiber connector, using 62.5/125um multimode fiber cable RJ-45 connector, using UTP 100 ohm Cat 5 cableWavelength 1310nmMaximum Segment Length UTP cable (10/100 Base-FX) : up to 100 meters multimode cable, (10/100 Base-FX) : up to 2000 metersTemperature 0ºC to 70ºC (Operating)External Power Supply Input Rating : 110 or 220 VAC, 50-60Hz Output Rating : 9VDC, 800mA

::: 10/100 Base-TX to 10/100 Base-FX Fiber SC/ST Converter (Multimode) :::

Page 61: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Converter

::: Features :::

The MSC series are fast ethernet 100Base-FX fiber converter specially designed for the fiber optic cablingconversion between 1300nm multimode and 1300nm singlemode. The full duplex cabling in multimode andsinglemode offers bandwidth of up to 200Mbps and allows the transmission distance up to 2Km over multimodeand 20Km over singlemode. There are 40Km and 100Km options for special applications over singlemode fiber.

IEEE 802.3 u 100 Base-FX StandardsSupport half duplex and full duplexSupport multimode fiber 50/125 nm or 62.5/125 nm or 100/140 nmSupport singlemode fiber 8.3/125, 8.7/125, 9/125 and 10/125 nm

::: Specification :::

::: Ordering Information :::Part Number Description

LTCV-SMMM-SC-20 100 Base - FX SC multimode 2 Km to SC Singlemode 20 KmLTCV-SMMM-SC-40 100 Base - FX SC multimode 2 Km to SC Singlemode 40 KmLTCV-SMMM-SC-100 100 Base - FX SC multimode 2 Km to SC Singlemode 100 Km

Standards IEEE 802.3u 100 Base-TX/10 Base-FXFiber Port Connector SC model : Two connector 1300 nm VF-45 Model : Two MT-RJ Connector 1300 nm MT-RJ Model : Two MT-RJ Connector 1300 nmFiber cable 50/125, 62.5 or 100 140um multimode 8.3/125, 8.7/125, 9/125 or 10/125um singlemodeMultimode Fiber cable Limitation Multimode half duplex : 412m Multimode full duplex : 2 KmSinglemode Fiber Cable Limitation SC singlemode full duplex : 20 Km SC 4 Singlemode full duplex : 40 Km SC 6 Singlemode full duplex : 60 KmData Transfer Rate 100Mpbs for half duplex mode 200 Mpbs for half duplex modeLED Indication Multimode fiber port : Link / Actrivity Singlemode fiber port : Link / ActrivityPower Requirement 1A @ + 5VDCOperating Temperature 0~50ºC (32º ~ 122ºF)Operating Humidity 5% - 9%, Non condensingDimension 26.2 (H) x 70.3 (W) x 94 mmCertificate CE Mark PCC Part 15 Class A

::: Multimode To Singlemode :::

Page 62: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Converter

::: Features :::

The FIBI-1000 is a standalone optical fiber media converter for 1000Base Ethernet to fiber that also provides NMS functions for Link-Loss-Forwarding, Remote-Monitoring-Status, and Loop-Back-Test. When auto-negotiation is selected, these units will autonatically tailor themselves to convert both half-duplex and full-duplex signals, depending on your specific networks needs.

::: Specification :::

Complies with IEEE 802.3ab, 1000Base-TX, IEEE 802.3z, 1000Base-SX/LX Gigabit Ethernet Standards.Provides one 1000Base-TX port, one 1000Base-SX/LX port, voltage 3.3V {SX-Multi-mode, LX- Single-mode}Three versions supports fixed SC or LC connector types, GBIC socket with SC, or SFP with LC. Sockets allow easy replacement of the snap-out transceiver models.Supports Full-duplex and Half-duplex mode for the Fiber and LAN ports.Automatic MDI/MDX crossover function.6 diagnostic LEDs for Power, TX link/transmit, FX link/transmit, Full/Half Duplex mode, CPE, LLF and LBT.Advanced Features: 1) Supports Link-Loss-Forwarding function via front panel DIP switch. 2) Supports for the Loop-Back test via front panel DIP switch.3) Supports remote monitor status via front panel DIP switch.

EnvironmentTemperature 0ºC to 50ºC (Operating),0ºC to 70ºC (Storage)Humidity 20% to 80% Non-condensing (Operating), 10% to 90% (Storage)Dimension 122.6mm(L) x 85.6mm(W) x 20mm (H)Weight 0.663lbs (300g)Power ModuleAC Power Module Input Universal 90 ~ 264 VACFrequency 47 ~ 63 HzOutput DC 12V, 8.5AEMI FCC Class A, CE Power Consumption <4WPower Budget Multimode >13dB : 0.55kmSinglemode >10.5dB : 10km >18dB : 30km >19dB : 50km

::: 1000 Base-TX to 1000 Base LX Gigabit To Ethernet Converter :::

Page 63: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Converter

::: Fiber To RS-232/423/485 Converter :::

::: Features :::

The FIBI-485A provides a fiber converter solution to extend RS-485 transmission distance up to 4Km over multimode fiberor up to 120Km over single mode fiber. The converter is equipped with multiple interface circuits, for connection to RS-232, RS-422, or RS-422/485 (2 or 4-wire). The FIBI-485A secures data transmissions over EMI resistant fiber at speed up to 256kbps for RS-232, or up to 1024kbps for RS-422/485.

::: Specification :::

Selectable data I/F for RS-232/423/485/TTL.Selectable for two or four wire RS-485/422.Speeds up to 256kbps for RS-232 and RS-423. Speeds up to 102kbps for RS-485/422.Extend transmission distance up to 120Km.Supply +5V (60mA) output for external device.

OpticalWavelength 1310/850nm Optical Mode Single/MultimodeOperating Distance up to 4Km on multi-mode up to 120Km on single modeFiber Type 50/125um, 60/125umOptical Budget 14dB Transmitter Power -15dBm Receiver Sensitivity -29dBmData SignalData Formats: RS-485/422 2-Wire RS-485/422 4-Wire RS-232+RTS/CTS 5-Wire RS-2325 3-Wire RS-423+RTS/CTS 5-Wire RS-423 3-WireBaud Rate: RS-485 1024kbps RS-232 120kbps RS-423 120kbps TTL 1024kbpsBit Error Rate: <10-10

ElectricalInput voltage 12-18VDC Current Requirement 300mAPower Consumption 5 WattsConnectorsOptical ST TypeData 6-Position detachableMechanicalLength 138mmWidth 86mmHeight 20mmWeight 660g

Page 64: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Converter

::: Product Overview :::

::: FOM - Series Fiber Optic Multiplxer :::

::: Advantages :::

The FOM new generation of the manageable fiber optic multiplexer, which is designed to extend transmissiondistance of 4 / 8 / 16 E1s data / voice over single core or dual core of single mode fiber cable with distance upto 50Km. FOM Fiber Optic Multiplxer are designed to used in LAN environment, mobile basic station to MSC,PABX extension & etc. Integrated with transmission and multiplex function, FOM receives and deliver synchronous E1 data from G.703networks over fiber optics. 1+1 optical protection is available. For the higher flexibility, dual E1 interface connectorsof 75 and 120 ohm are equipped for the 4E1 and 8E1 model; with user definable for the E1 impedance interface. FOM enhances the management capability with SNMP and GUI web management by the optional built-inmanagement module. CLI also support via telnet or RS485 / RS232 console port. LED indicators are equipped on thefront panel for all interfaces transmission statues. The FOM support local and remote loopback for the test of tributaryand optical interfaces by hardware switches or management software.

4 / 8/ 16 G.703 E1 ports Front panel LED indicatorsLocal and remote loopback facilitySingle core fiber with built-in WDMOptional 1+1 fiber protectionDual E1 interface for 4E1 and 8E1 modelRedundancy power supply with any combination of AC or DC power19” rack mountableSNMP v1 / v2 Management

Page 65: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Converter

::: FOM - Series Fiber Optic Multiplxer :::

::: Technical Specification :::

E1 InterfaceStandard: ITU-T G.703Data Rate: 2.048Mbits + 50ppmLine Code: HDB3Impedance: 75 ohm / BNC, 120 ohm / RJ45 Jitter & Wander: ITU-T.G823

Network ManagementStandard: SNMP v1, v2 Interface: 10Base-T EthernetConnector: RJ45

Web ManagementStandard: IE 6.0Interface: IP / Ethernet

CLI ConsoleStandard: RS232 / RS485 serial com portConnector: DB25F

EnvironmentWorking Temperature: 0 ~ 50 oCStorage Temperature: - 40 ~ + 70oCRelative Humidity: <95%

Optical InterfaceConnector: FC-PC or SC or STFiber Optic Type: 1310 / 1550 nm, SM LD

Dual Core Fiber Transmit Power: >= -10dBmReceive Sensitivity: <= -38dBm (BER<= -10)Link Budget: 28 dBm

Single Core FiberMultiplexing: WDMTransmit Power: >= -14 dBmReceive Sensitivity: <= -32 dBm (BER<= -10)Link Budget: 18 dBm

Power Supply AC Power 110V or 220VRange: 95 ~ 120V or 180 ~ 260V DC Power - 48V or + 24VRange: - 38 ~ - 72V or 18 ~ 36VPower Consumption: < 10W

::: Ordering Information :::

Part Number DescriptionLTOC-FOM-4E1-M Fiber Optic Multiplxer 4xE1 (Dual Interface Selectable)

LTOC-FOM-8E1-M Fiber Optic Multiplxer 8xE1 (Dual Interface Selectable)

LTOC-FOM-16E1-M Fiber Optic Multiplxer 16xE1 (75 or 120 ohm orderable)

ROUTER

SWITCH

MUX

ROUTER

SWITCH

MUX

E1

FOM-M(MK2) FOM-M(MK2)

E1

E1

E1

E1

E1

Page 66: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Converter

::: Features :::

The FIBI Family are the standalone fiber media converters available in a number of different models. The FIBI-E1 is a fiber media transport for G.703 E1transmission. The BNC model provides unbalanced 75Ohm coaxial connections while the RJ-45 model provides balanced 120Ohm connections over twisted pair wiring. The FIBI-T1 is a fiber media transport for G.703 T1 transmission and features an RJ-45 connector for connection to 100 Ohm twisted pair wiring.All media converters are available with either multi-mode and single-mode optical tranceivers and with connectors for SC, ST, FC, LC, or MT-RJ.

::: Specification :::

T1/E1 RJ45/RJ48 or Coax to Fiber converterSupports multimode, single-mode, and single fiber with ST, SC, LC and MT-RJ connectorsUser-selectable Local Loop-Back, Force 1's to Copper, Force 1's to Fiber, and Fiber Test modesLED indicators - Power, Fiber Link, LINE (E1 or T1) Link, Test modeNetwork Management via Terminal or SNMP cardSupports AMI or B8ZS/HDB3 modesRJ45 port with DCE/DTE switch

E1 SpecifivationPorts 1 portStandards ITU-T G.703, G.704, G.706, G.732, G.823Framing Unframed, CAS, CCSData rate 2.048MbpsLine Code HDB3Receive Level Short haul - 15dbLine impedance 75 ohms 120 ohmsConnector RJ-45 for 120ohms BNC for 75 ohms

Distance Connectivity002 2Km [multi-mode only]015 15Km030 30Km050 50Km120 120Km

E1 SpecifivationPorts 1 portStandards ITU-T G.703, G.704,AT&T TR-62411,ANSI T1.403 Framing Unframed, D4, ESFData rate 1.544 MbpsLine Code B8ZS, AMIReceive level Short haul - 15dbLine impedance 100ohmsConnector RJ-45

::: Single E1/T1 to Fiber Converter :::

Page 67: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

1.7.1 Double Suspension Set1.7.2 Suspension Set1.7.3 Tension Set1.7.4 Down Lead Cushions1.7.5 Tighten Harness1.7.6 Stock Bridge Damper1.7.7 OPGW Closure

OPGW & ADSS Accessories

Page 68: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

OPGW & ADSS Accessories

Double Suspension Set Tension SetSuspension Set

Stock Bridge Damper Vibration DamperOPGW Closure

Down Lead Cushions

Tighten Harness

TGX

ZZJG

TGJ TTZX

TTZJ

Page 69: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Suspension Clamps for ADSS

Span Length of structuralreinforcing rods

Length of suspension rods

LTOC-ADSS-SUS-AC0200 150~200 1600 1000 3.2LTOC-ADSS-SUS-AC0300 201~300 1800 1200 3.5LTOC-ADSS-SUS-AC0400 301~400 1900 1300 3.8LTOC-ADSS-SUS-AC0500 401~500 2000 1400 4.1LTOC-ADSS-SUS-AC0600 501~600 2200 1600 4.5LTOC-ADSS-SUS-AC0800 601~800 2400 1800 4.8LTOC-ADSS-SUS-AC1000 801~1000 2600 2000 5.0

Weight(kg)Type

Ordering Information

::: Cross Section Diagram :::

1. Clevis thimble(optional)2. Cast aluminium housing3. Elastomer insert clamp4. Suspension rods5. Structural reinforcing rods

::: Characteristic :::

::: Technical characteristic :::

::: Ordering Information :::

Single preformed rods.Simple Structure with low weightEasy to installVertical break load ≥ 70kN

::: Applications :::All kinds of ADSSCorner of the line less than 300Pole or tower use

The structure of the two of preformed strand string could make better protection for FOC with long time unequal load operation. It can bear larger dynamic stress and has larger grip strength.Because of the large touching area, equally distributed power and non intensive stress pivot, FOC is strengthened at the fixing point and therefore better protected.Selected materials are well against corrosion, oxidation and aging, and these features could lengthen the operation of FOC.Simple structure and convenient installation need no special tools or maintenance.

Page 70: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Tension Clamps for ADSS

::: Cross Section Diagram :::

1. Clevis thimble(optional)2. PH extension link(optional)3. Thimble eye4. ID tag5. Dead-end component6. Structural reinforcing rods

::: Technical characteristic :::

::: Applications :::Use in terminal poles, tension poles, connecting poles and conner(elevation) poles having turning angle more than 250

Wall of both inner and outer standing wires are sprayed with carborundum in order to increase the damping effect, through which cables are finely protected.Cables are finely protected because stress is equally distributed in large touching area without intensive stress pivot. All the selected materials are against corrosion and have long operation life.Simple structure, easy installation and free from special tools or maintenance.

The clamp distributes radial pressure equally and passes axial force. It also provides safe and reliable gripping power in the premise of protecting cable to avoid damage.

Page 71: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

OPGW Closure

Aluminum Alloy case and bracket designStainless Steel Clamp and " O" ring sealing design, no re-entry tape or sleeve required during re-access. Save costNo loose part - easy of installationMultiple drop cable ports for ready access Mountable in pole for aerial applicationsNo special training and tooling requierd

- Dimensions : S - 450mm (L) x 210mm (O.D)- Gross weight : 9 kg

::: Features :::

::: Ordering Information :::

Part Number DescriptionLTOC-OFC-OPGW-12 Optical Dome Closure OFC-OPGW 12 coreLTOC-OFC-OPGW-24 Optical Dome Closure OFC-OPGW 24 coreLTOC-OFC-OPGW-36 Optical Dome Closure OFC-OPGW 36 coreLTOC-OFC-OPGW-48 Optical Dome Closure OFC-OPGW 48 coreLTOC-OFC-OPGW-72 Optical Dome Closure OFC-OPGW 72 core

::: Specification :::

OFC-OPGW Optical Dome Closure are designed for easy assembly and re-entry in the external plant for OPGW and ADSS cable applications. The closure featured a mechanical cable sealing system which made re-entry at no cost. The waterproof and rugged construction makes these closures perfect for the extreme aerial plant environment.

::: OFC-OPGW Dome Closure :::

Page 72: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

1.8.1 Fiber Optic Tool1.8.2 Fiber Optical Basic Tool Kit1.8.3 Fiber Optical TerminationKit1.8.4 High Precision Cleaver1.8.5 V-Groove Mechanical Splice1.8.6 Fiber Optic Cleaning Kit

Fiber Optic Tools

Page 73: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Tools and Consumables

Jacket Stripper

LTOC-TL-JS LTOC-TL-STR-CLA LTOC-TL-SP

Fiber Stripper Fiber Stripper Fiber Stripper

LTOC-TL-NS

Kevlar Cutter - Premium

LTOC-TL-KC-PR LTOC-TL-375 LTOC-TL-CRP

Fiber Optic Scissors Fiber Optic Crimping Tool Buffer Tube Stripper

LTOC-TL-BS

Tube Slitter

LTOC-TL-TS LTOC-TL-QC-HAR/PRI LTOC-TL-PGP

Fiber Quick Cure Epoxy Polish Glass Plate Curing Oven

LTOC-TL-CO

Epoxy Syringe

LTOC-TL-SE LTGN-TL-CP-B LTSS-TL-INS

Blower Cleaner Inspection ScopeSuper Fine Tip StainlessTweezer

LTGN-TL-GCP-005

Scribe Tool (Carbide)

LTSS-TL-ST-CAR LTSS-TL-ST-R

Scribe Tool (Ruby) Alcohol Dispensor Bottle

LTOC-TL-BOT LTOC-TL-PIW

Piano Wire

Page 74: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Tools and Consumables

Cleaning Cassette

LTOC-TL-CTP LTSS-TL-KW LTOC-TL-PF-XX

Lint Free Tissue Polishing Film Polishing Jig

LTOC-TL-PJ-XX

Mechanical Lab Splice

LTOC-MLS LTOC-TL-VGRO LTOC-TL-FC-XXXX

V-Groove TemporarySplice Fiber Cleaver

In-Adapter Ferrule Cleaner

LTOC-IFC-2.5

Fiber Termination Tool Kit

LTOC-TL-TER-KIT LTOC-TL-BK-KIT LTOC-TL-CTP

Fiber Basic Tool Kit Fiber Cleaning KitFiber Breakout Kit (Blue-Big)

LTOC-BOK-B-BLU

Fiber Breakout Kit (Beige-Medium)

LTOC-BOK-M-BEI LTOC-BOK-S-YEL-A LTOC-BOK-S-YEL-B

LTOC-BOK-OV-XX

Fiber Tube

Fiber Breakout Kit (Yellow-Big)

Fiber Breakout Kit (Yellow-Small)

Fiber Breakout Kit (Black-Small)

LTOC-BOK-S-BLK

Page 75: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Basic Tool Kit

::: Product Overview :::

::: Ordering Information :::

The Fiber Optic Basic Tool Kit contained all the tools necessary for the fiber optic preparation requirement. The kit also complete with consumables may be ordered separately.

Kit Contents: Quantity

1. Buffer Tube Stripper 1 unit2. Kelvar Scissors 1 unit3. Lint-Free Wipe Tissues 1 box4. Utility Knife 1 unit5. Cutting Plier 1 unit6. Measuring Tape 1 unit7. Multipurpose Screw Driver 1 unit8. Jacket Stripper 1 unit9. Tweezers 1 unit10. Fiber Stripper 1 unit11. Alcohol Bottle 1 unit12. Cable Cutter 1 unit13. Waste Fiber Storage Box 1 unit14. Cable Marker 1 unit15. Cable Ties 10 unit16. Economy Tie Label 10 unit17. Carrying Case 1 unit

Optional Items :

1. High Precision Fiber Cleaver2. Visual Fault Locator3. Cable Sheath Slitter

Part Number DescriptionLTOC-TL-BK-KIT Fiber Tool Basic Tool Kit

Page 76: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

High Precision Cleaver

::: Advantages :::

::: Ordering Information :::

Automatic cleaving Low cleaving angle : 0.5ºLife time: 48,000 timesFor both single and ribbon fiberHigh degree of hardness8º angled cleaver is available

::: Specification :::

Part Number DescriptionLTOC-TL-FC-CI 01 Tool Fiber Cleaver CI-01LTOC-TL-FC-CI 02 Tool Fiber Cleaver CI-02

LTOC-TL-FC-CI 03 Tool Fiber Cleaver CI-03

CI-01 CI-03CI-02Fiber Diameter 125um 80um, 125um 125umCoating Diameter 0.25-0.9mm 0.25-0.9mm 0.25-0.9mmCleave Length 10-25mm (Single, Ribbon) 5-20mm (Single) 10-25mm (Single & Ribbon)

10-25mm (Single)Fiber Count Single & Ribbon (2-12) Single & Ribbon (2-24) Single & Ribbon (2-24)Cleaving Angle 0.5º (Single Fiber) 0.5º (Single Fiber) 0.5º (Single Fiber)Dimension 58mm X 55mm x 48mm 84mm x 65mm x 54mm 58mm x 66mm x 48mmWeight 260g 470g 290g

Distinction Manual (Six Action) Automatic (one action) Automatic (one action)Waste basket

Page 77: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Fiber Optic Termination Kit

::: Product Overview :::

The Fiber Optic Termination Kit contained all the tools necessary for the fiber optic termination requirement. The kit also complete with consumables may be ordered separately.

Kit Contents: Quantity

1. Buffer Tube Stripper 1 unit2. Kelvar Scissors 1 unit3. Lint-Free Wipe Tissues 1 box4. Utility Knife 1 unit5. Cutting Plier 1 unit6. Measuring Tape 1 unit7. Multipurpose Screw Driver 1 unit8. Jacket Stripper 1 unit9. Tweezers 1 unit10. Fiber Stripper 1 unit11. Alcohol Bottle 1 unit12. Cable Cutter 1 unit13. Syringes 1 unit14. Polishing Jig ( SC or FC or ST ) 1 unit15. Waste Fiber Storage Box 1 unit16. Polishing Film 0.3 um 5 unit17. Polishing Film 3.0 um 5 unit

18. Fiber Optic Crimping Tool 1 unit19. Fiber Scribe Tool 1 unit20. Polish Glass Plate 1 unit21. Carrying Case 1 unit

Optional Items : 1. Heat Curving Oven 2. Inspection Microscope 400X3. Quick Cure Epoxy Set 4. Visual Fault Locator

::: Ordering Information :::

Part Number DescriptionLTOC-TL-TER-KIT Fiber Tool Termination Kit

Page 78: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

V-Groove Mechanical Splice

::: Advantages :::

::: Ordering Information :::Part Number Description

LTOC-TL-VGRO-2525 V-Groove Mechanical Splice for 0.25mm x 0.25mm FiberLTOC-TL-VGRO-2509 V-Groove Mechanical Splice for 0.25mm x 0.9mm FiberLTOC-TL-VGRO-0909 V-Groove Mechanical Splice for0.9mm x 0.9mm Fiber

Higher surface tension between upper lid and base lid. The middles lid controls the tensionof two side lids properlyThe average insertion loss is less than 0.5dBAvailable for 0.25mm and 0.9mm fiber typeOptical devices application for temporary testing

V-Groove mechanical splice is used for temporary fiber connection for testing during cable drum test,R&D ornetwork testing. V-Groove mechanical Splice is a user friendly temporary splice device with low insertion loss.

Page 79: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

::: Product Overview :::

Kit Contents: Quantity

1. Mini Foam Swabs (50) 1 unit2. Kim Wipes 1 unit3. Optic Preps 1 box4. Alcohol Dispenser Bottle 1 unit

::: Ordering Information :::

Part Number DescriptionLTOC-TL-CTP Fiber Tool Cleaning Kit

Fiber Optical Cleaning Kit

Page 80: Contentcomscience-network.com/newpdf/W02 Catalogue/PB 01… ·  · 2013-04-10Content 1.1 Fiber Optic Cable 1.1.1 Direct Buried ... 1.3.11.2 OFC-DS ... Geometrical Parameters Of Fibres

Other Products

Coaxial

Voice

Racking- Equipment/Racks- Open System Racks- ODF/ MMF/ DDF Frames- Outdoor Equipment Cabinets- Customized Racking

- 75 Ohm to 120 Ohm Balin- IDC Type Balun- Balun Panels- Balun Pigtail

- Coaxial Frames & Tools- Coaxial Connectors & Adapters- Coaxial Panels & Frames

RF- RF Connectors & Adapters- Feeder Clamp, Grounding KitsA t & RF P i P d t

- Data Cables- Work Station Solutions- Patch Panels- 110 Wiring System

Fiber Optic

Magazine Arrestor- Back Mount Frame- DP Boxes- Tools