98 Order forms Masterpact NT or NW circuit breakers and switch-disconnectors Page 100 Masterpact NT or NW source-changeover systems for 2 devices Page 101 Masterpact NW source-changeover systems for 3 devices Page 102 Masterpact NT 630 - 1600A Fixed circuit breakers Page 103 Drawout circuit breakers Page 106 Accessories Page 110 Fixed switch-disconnectors Page 111 Drawout switch-disconnectors Page 112 Masterpact NW 800 - 6300A Fixed circuit breakers Page 113 Drawout circuit breakers Page 117 Accessories Page 122 Fixed switch-disconnectors Page 124 Drawout switch-disconnectors Page 125 Low voltage power distribution Air circuit breakers & switch-disconnectors Electrical distribution 1.3

Transcript of COMPLETE COVER 08 - · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed...

Page 1: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

98

Order formsMasterpact NT or NW circuit breakers and switch-disconnectors Page 100

Masterpact NT or NW source-changeover systems for 2 devices Page 101

Masterpact NW source-changeover systems for 3 devices Page 102

Masterpact NT 630 - 1600AFixed circuit breakers Page 103

Drawout circuit breakers Page 106

Accessories Page 110

Fixed switch-disconnectors Page 111

Drawout switch-disconnectors Page 112

Masterpact NW 800 - 6300AFixed circuit breakers Page 113

Drawout circuit breakers Page 117

Accessories Page 122

Fixed switch-disconnectors Page 124

Drawout switch-disconnectors Page 125

Low voltage power distributionAir circuit breakers & switch-disconnectors

Electrical distribution

1.3

Page 2: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

99

1.3

Masterpact NT and NW source-changeover systemsNT interlocking Page 126

NW interlocking Page 126

Remote controlled Page 126

Page 3: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

100

Masterpact NT or NW Circuit breakers and switch-disconnectors

1.3

Page 4: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

101

1.3

Source-changeover systems for 2 devicesMasterpact NT or NW Circuit breaker and switch-disconnectors

Page 5: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

102

Source-changeover systems for 3 devicesMasterpact NW Circuit breaker and switch-disconnectors

1.3

Page 6: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference415V) 525V) (A at 40°C)

H1 42 42 3 630 NT06H13F5.0A

800 NT08H13F5.0A

1000 NT10H13F5.0A

1250 NT12H13F5.0A

1600 NT16H13F5.0A

H2 50 42 3 630 NT06H23F5.0A

800 NT08H23F5.0A

1000 NT10H23F5.0A

1250 NT12H23F5.0A

1600 NT16H23F5.0A

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference415V) 525V) (A at 40°C)

H1 42 42 3 630 NT06H13F2.0A

800 NT08H13F2.0A

1000 NT10H13F2.0A

1250 NT12H13F2.0A

1600 NT16H13F2.0A

H2 50 42 3 630 NT06H23F2.0A

800 NT08H23F2.0A

1000 NT10H23F2.0A

1250 NT12H23F2.0A

1600 NT16H23F2.0A

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference415V) 525V) (A at 40°C)

H1 42 42 3 630 NT06H13F2.0A

800 NT08H13F2.0A

1000 NT10H13F2.0A

1250 NT12H13F2.0A

1600 NT16H13F2.0A

H2 50 42 3 630 NT06H23F2.0A

800 NT08H23F2.0A

1000 NT10H23F2.0A

1250 NT12H23F2.0A

1600 NT16H23F2.0A

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference415V) 525V) (A at 40°C)

H1 42 42 3 630 NT06H13F5.0A

800 NT08H13F5.0A

1000 NT10H13F5.0A

1250 NT12H13F5.0A

1600 NT16H13F5.0A

H2 50 42 3 630 NT06H23F5.0A

800 NT08H23F5.0A

1000 NT10H23F5.0A

1250 NT12H23F5.0A

1600 NT16H23F5.0A

103

1.3

Masterpact NT06 - NT16 Fixed Circuit Breakers

MASTERPACT NT06 - NT16 CIRCUIT BREAKER REAR HORIZONTALLY CONNECTED WITHMICROLOGIC 2.0A CONTROL UNIT

MASTERPACT NT06 - NT16 CIRCUIT BREAKER REAR HORIZONTALLY CONNECTED WITHMICROLOGIC 5.0A CONTROL UNIT

A complete Masterpact fixed circuit breaker device includes:1) the basic circuit breaker2) a micrologic control unit3) top and bottom connections4) top and bottom interphase barriers5) 4x (OF) ON/OFF indication contacts 6) 1x (SDE) fault trip indication contact Note:* If a Micrologic 7.0 A is selected, it is compulsory to add the external sensor.Optional: * Please contact your local Schneider sales office for assistance 1) complete 4 pole circuit breakers2) front and vertical connections3) communication options and various auxiliaries and accessories may also be added.

Page 7: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Type Description Reference

ON/OFF indication Changeover contacts (6A - 240V), 4 supplied Standardcontacts (OF) standard

1 low-level OF to replace 1 standard OF (4 max.) 47339

Fault trip indication contacts Changeover contact (5A - 240V), 1 supplied Standard(SDE) standard

1 additional SDE (5A - 240V) 47340

1 additional low-level SDE 47341

Type Description Position Poles/Quantity Reference

Interphase barriers Top/Bottom 3P/4P (3 parts) 33646

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference415V) 525V) (A at 40°C)

H1 42 42 3 630 NT06H13F6.0A

800 NT08H13F6.0A

1000 NT10H13F6.0A

1250 NT12H13F6.0A

1600 NT16H13F6.0A

H2 50 42 3 630 NT06H23F6.0A

800 NT08H23F6.0A

1000 NT10H23F6.0A

1250 NT12H23F6.0A

1600 NT16H23F6.0A

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference415V) 525V) (A at 40°C)

H1 42 42 3 630 NT06H13F7.0A

800 NT08H13F7.0A

1000 NT10H13F7.0A

1250 NT12H13F7.0A

1600 NT16H13F7.0A

H2 50 42 3 630 NT06H23F7.0A

800 NT08H23F7.0A

1000 NT10H23F7.0A

1250 NT12H23F7.0A

1600 NT16H23F7.0A

MASTERPACT NT06 - NT16 INDICATION CONTACTS

104

Masterpact NT06 - NT16 Fixed Circuit Breakers

1.3

Type Description Reference

ON/OFF indication Changeover contacts (6A - 240V), 4 supplied Standardcontacts (OF) standard

1 low-level OF to replace 1 standard OF (4 max.) 47339

Fault trip indication Changeover contact (5A - 240V), 1 supplied Standardcontacts (SDE) standard

1 additional SDE (5A - 240V) 47340

1 additional low-level SDE 47341

Masterpact NT06 - NT16 Fixed circuit breakers

MASTERPACT NT06 - NT16 CONNECTION ACCESSORIES

Description Position Poles/Quantity Reference

Interphase barriers Top/Bottom 3P/4P (3 parts) 33646

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference415V) 525V) (A at 40°C)

H1 42 42 3 630 NT06H13F6.0A

800 NT08H13F6.0A

1000 NT10H13F6.0A

1250 NT12H13F6.0A

1600 NT16H13F6.0A

H2 50 42 3 630 NT06H23F6.0A

800 NT08H23F6.0A

1000 NT10H23F6.0A

1250 NT12H23F6.0A

1600 NT16H23F6.0A

MASTERPACT NT06 - NT16 CIRCUIT BREAKER REAR HORIZONTALLY CONNECTED WITHMICROLOGIC 6.0A CONTROL UNIT

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference415V) 525V) (A at 40°C)

H1 42 42 3 630 NT06H13F7.0A

800 NT08H13F7.0A

1000 NT10H13F7.0A

1250 NT12H13F7.0A

1600 NT16H13F7.0A

H2 50 42 3 630 NT06H23F7.0A

800 NT08H23F7.0A

1000 NT10H23F7.0A

1250 NT12H23F7.0A

1600 NT16H23F7.0A

MASTERPACT NT06 - NT16 CIRCUIT BREAKER REAR HORIZONTALLY CONNECTED WITHMICROLOGIC 7.0A CONTROL UNIT

Page 8: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Type Description Voltage Reference

Remote Gear motor (MCH) AC 48V 47391ON / OFF 50/60Hz

100-130V 47395

200-240V 47396

277-415V 47398

440-480V 47400

DC 24-30V 47390

48-60V 47391

100-130V 47392

200-250V 47393

Instant. Standard XF (closing AC 12V DC 47349

voltage voltage 50/60Hz 24-30V DC, 47350

releases release) or DC 24V AC

48-60V DC, 47351

48V AC

100-130V 47352

200-250V 47353

277V AC 47354

380-480V 47355

AC

MX AC 12V DC 47359

(opening 50/60Hz 24-30V DC, 47360

voltage or DC 24V AC

release) 48-60V DC, 47361

48V AC

100-130V 47362

200-250V 47363

277V AC 47364

380-480V 47365

AC

MN AC 24-30V DC, 47380

(under- 50/60Hz 24V AC

voltage or DC 48-60V DC, 47381

release) 48V AC

100-130V 47382

200-250V 47383

380-480V 47385

AC

105

1.3

Masterpact NT06 - NT16 Fixed Circuit Breakers

Masterpact NT06 - NT16 Fixed circuit breakers

MASTERPACT NT06 - NT16 REMOTE OPERATION

Type Description Voltage Reference

Remote Gear motor (MCH) AC 48V 47391ON / OFF 50/60Hz

100-130V 47395

200-240V 47396

277-415V 47398

440-480V 47400

DC 24-30V 47390

48-60V 47391

100-130V 47392

200-250V 47393

Instant. Standard XF (closing AC 12V DC 47349

voltage voltage 50/60Hz 24-30V DC, 47350

releases release) or DC 24V AC

48-60V DC, 47351

48V AC

100-130V 47352

200-250V 47353

277V AC 47354

380-480V 47355

AC

MX AC 12V DC 47359

(opening 50/60Hz 24-30V DC, 47360

voltage or DC 24V AC

release) 48-60V DC, 47361

48V AC

100-130V 47362

200-250V 47363

277V AC 47364

380-480V 47365

AC

MN AC 24-30V DC, 47380

(under- 50/60Hz 24V AC

voltage or DC 48-60V DC, 47381

release) 48V AC

100-130V 47382

200-250V 47383

380-480V 47385

AC

Page 9: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference415V) 525V) (A at 40°C)

H1 42 42 3 630 NT06H13D5.0A

800 NT08H13D5.0A

1000 NT10H13D5.0A

1250 NT12H13D5.0A

1600 NT16H13D5.0A

H2 50 42 3 630 NT06H23D5.0A

800 NT08H23D5.0A

1000 NT10H23D5.0A

1250 NT12H23D5.0A

1600 NT16H23D5.0A

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference415V) 525V) (A at 40°C)

H1 42 42 3 630 NT06H13D2.0A

800 NT08H13D2.0A

1000 NT10H13D2.0A

1250 NT12H13D2.0A

1600 NT16H13D2.0A

H2 50 42 3 630 NT06H23D2.0A

800 NT08H23D2.0A

1000 NT10H23D2.0A

1250 NT12H23D2.0A

1600 NT16H23D2.0A

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference415V) 525V) (A at 40°C)

H1 42 42 3 630 NT06H13D5.0A

800 NT08H13D5.0A

1000 NT10H13D5.0A

1250 NT12H13D5.0A

1600 NT16H13D5.0A

H2 50 42 3 630 NT06H23D5.0A

800 NT08H23D5.0A

1000 NT10H23D5.0A

1250 NT12H23D5.0A

1600 NT16H23D5.0A

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference415V) 525V) (A at 40°C)

H1 42 42 3 630 NT06H13D2.0A

800 NT08H13D2.0A

1000 NT10H13D2.0A

1250 NT12H13D2.0A

1600 NT16H13D2.0A

H2 50 42 3 630 NT06H23D2.0A

800 NT08H23D2.0A

1000 NT10H23D2.0A

1250 NT12H23D2.0A

1600 NT16H23D2.0A

106

Masterpact NT06 - NT16 Drawout circuit breakers

1.3

A complete Masterpact drawout circuit breaker device includes:1) the basic circuit breaker2) a micrologic control unit3) a chassis4) top and bottom connections5) bottom interphase barriers6) 4x (OF) ON/OFF indication contacts 7) 1x (SDE) fault trip indication contact Note: * If a Micrologic 7.0 A is selected, it is compulsory to add the external sensor.* Safety shutters are now supplied standard as part of the chassisOptional: * Please contact your local Schneider sales office for assistance 1) complete 4 pole circuit breakers2) front and vertical connections 3) communication options and various auxiliaries and accessories may also be added.

MASTERPACT NT06 - NT16 CIRCUIT BREAKER HORIZONTALLY REAR CONNECTED WITHMICROLOGIC 2.0A

MASTERPACT NT06 - NT16 CIRCUIT BREAKER HORIZONTALLY REAR CONNECTED WITHMICROLOGIC 5.0A

Page 10: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Type Description Position Poles/Quantity Reference

Interphase barriers - 3P/4P (3 parts) 33768

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference415V) 525V) (A at 40°C)

H1 42 42 3 630 NT06H13D7.0A

800 NT08H13D7.0A

1000 NT10H13D7.0A

1250 NT12H13D7.0A

1600 NT16H13D7.0A

H2 50 42 3 630 NT06H23D7.0A

800 NT08H23D7.0A

1000 NT10H23D7.0A

1250 NT12H23D7.0A

1600 NT16H23D7.0A

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference415V) 525V) (A at 40°C)

H1 42 42 3 630 NT06H13D6.0A

800 NT08H13D6.0A

1000 NT10H13D6.0A

1250 NT12H13D6.0A

1600 NT16H13D6.0A

H2 50 42 3 630 NT06H23D6.0A

800 NT08H23D6.0A

1000 NT10H23D6.0A

1250 NT12H23D6.0A

1600 NT16H23D6.0A

Description Position Poles/Quantity Reference

Interphase barriers - 3P/4P (3 parts) 33768

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference415V) 525V) (A at 40°C)

H1 42 42 3 630 NT06H13D7.0A

800 NT08H13D7.0A

1000 NT10H13D7.0A

1250 NT12H13D7.0A

1600 NT16H13D7.0A

H2 50 42 3 630 NT06H23D7.0A

800 NT08H23D7.0A

1000 NT10H23D7.0A

1250 NT12H23D7.0A

1600 NT16H23D7.0A

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference415V) 525V) (A at 40°C)

H1 42 42 3 630 NT06H13D6.0A

800 NT08H13D6.0A

1000 NT10H13D6.0A

1250 NT12H13D6.0A

1600 NT16H13D6.0A

H2 50 42 3 630 NT06H23D6.0A

800 NT08H23D6.0A

1000 NT10H23D6.0A

1250 NT12H23D6.0A

1600 NT16H23D6.0A

107

1.3

Masterpact NT06 - NT16 Drawout circuit breakers

MASTERPACT NT06 - NT16 CIRCUIT BREAKER HORIZONTALLY REAR CONNECTED WITHMICROLOGIC 6.0A

MASTERPACT NT06 - NT16 CIRCUIT BREAKER HORIZONTALLY REAR CONNECTED WITHMICROLOGIC 7.0A

MASTERPACT NT06 - NT16 CONNECTION ACCESSORIES

Page 11: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Type Description Reference

ON/OFF indication contacts Changeover contacts (6A - 240V), 4 supplied Standard(OF) standard

1 low-level OF to replace 1 standard OF (4 max.) 33806

Fault trip indication contacts Changeover contact (5A – 240V), 1 supplied Standard(SDE) standard

1 additional SDE (5A – 240V) 47430

1 additional low-level SDE 47431

Carriage switches (connected/ 1 connected position contact (3 max.) 33751

disconnected/test position) 1 test position contact (1 max.) 33752

Changeover contacts 1 disconnected position contact (2 max.) 33753

(6A – 240V):

Carriage switches (connected/ 1 connected position contact (3 max.) 33754

disconnected/test position) 1 test position contact (1 max.) 33755

And/or low-level changeover 1 disconnected position contact (2 max.) 33756

contacts:

Auxiliary terminals for 3 wire terminals (30 parts) 47071

chassis alone 6 wire terminals (10 parts) 47072

Jumpers (10 parts) 47900

Type Description Reference

Disconnected By padlocks VCPO Standard

position By Ronis 1 lock with 1 key + adaptation kit 33776

locking keylocks 2 locks - 2 same keys + adaptation kit 33777

2 locks - 2 different keys + adaptation kit 33778

Door interlock (1 part) Right-hand side of chassis (VPECD) 33786

Left-hand side of chassis (VPECG) 33787

Racking interlock Racking interlock (VPOC) 33788

Breaker mismatch protection Breaker mismatch protection (VDC) 33767

Type Description Reference

ON/OFF indication contacts Changeover contacts (6A - 240V), 4 supplied Standard(OF) standard

1 low-level OF to replace 1 standard OF (4 max.) 33806

Fault trip indication contacts Changeover contact (5A – 240V), 1 supplied Standard(SDE) standard

1 additional SDE (5A – 240V) 47430

1 additional low-level SDE 47431

Carriage switches (connected/ 1 connected position contact (3 max.) 33751

disconnected/test position) 1 test position contact (1 max.) 33752

Changeover contacts 1 disconnected position contact (2 max.) 33753

(6A – 240V):

Carriage switches (connected/ 1 connected position contact (3 max.) 33754

disconnected/test position) 1 test position contact (1 max.) 33755

And/or low-level changeover 1 disconnected position contact (2 max.) 33756

contacts:

Auxiliary terminals for 3 wire terminals (30 parts) 47071

chassis alone 6 wire terminals (10 parts) 47072

Jumpers (10 parts) 47900

Type Description Reference

Disconnected By padlocks VCPO Standard

position By Ronis 1 lock with 1 key + adaptation kit 33776

locking keylocks 2 locks - 2 same keys + adaptation kit 33777

2 locks - 2 different keys + adaptation kit 33778

Door interlock (1 part) Right-hand side of chassis (VPECD) 33786

Left-hand side of chassis (VPECG) 33787

Racking interlock Racking interlock (VPOC) 33788

Breaker mismatch protection Breaker mismatch protection (VDC) 33767

Masterpact NT06 - NT16 Drawout circuit breakers

C60A 5KA C CURVE (TYPE2)

108

C60A 5KA C CURVE (TYPE2)

1.3

MASTERPACT NT06 - NT16 INDICATION CONTACTS

MASTERPACT NT06 - NT16 CHASSIS LOCKING AND ACCESSORIES

Page 12: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Type Description Voltage Reference

Remote Gear motor (MCH) AC 48V 47461

ON / OFF 50/60Hz 100-130V 47465

200-240V 47466

277-415V 47468

440-480V 47470

DC 24-30V 47460

48-60V 47461

100-130V 47462

200-250V 47463

Instant. Standard XF AC 12V DC 47439

voltage (closing 50/60Hz 24-30V DC, 47440

releases voltage or DC 24V AC

release) 48-60V DC, 47441

48V AC

100-130V 47442

200-250V 47443

277V AC 47444

380-480V 47445

AC

MX AC 12V DC 33809

(opening 50/60Hz 24-30V DC, 33810

voltage or DC 24V AC

release) 48-60V DC, 33811

48V AC

100-130V 33812

200-250V 33813

277V AC 33814

380-480V 33815

AC

Ready to close contact 1 changeover contact - 47432(1 max.) PF (5A - 240V)

1 low-level changeover contact (PF) 47433

Instant. voltage releases MN AC 24-30V DC, 33819

(under- 50/60Hz 24V AC

voltage or DC 48-60V DC, 33820

release) 48V AC

100-130V 33821

200-250V 33822

380-480V 33824

AC

Type Description Voltage Reference

Remote Gear motor (MCH) AC 48V 47461

ON / OFF 50/60Hz 100-130V 47465

200-240V 47466

277-415V 47468

440-480V 47470

DC 24-30V 47460

48-60V 47461

100-130V 47462

200-250V 47463

Instant. Standard XF AC 12V DC 47439

voltage (closing 50/60Hz 24-30V DC, 47440

releases voltage or DC 24V AC

release) 48-60V DC, 47441

48V AC

100-130V 47442

200-250V 47443

277V AC 47444

380-480V 47445

AC

MX AC 12V DC 33809

(opening 50/60Hz 24-30V DC, 33810

voltage or DC 24V AC

release) 48-60V DC, 33811

48V AC

100-130V 33812

200-250V 33813

277V AC 33814

380-480V 33815

AC

Ready to close contact 1 changeover contact - 47432(1 max.) PF (5A - 240V)

1 low-level changeover contact (PF) 47433

Instant. voltage releases MN AC 24-30V DC, 33819

(under- 50/60Hz 24V AC

voltage or DC 48-60V DC, 33820

release) 48V AC

100-130V 33821

200-250V 33822

380-480V 33824

AC

109

1.3

Masterpact NT06 - NT16 Fixed Circuit BreakersMasterpact NT06 - NT16 Drawout circuit breakers

C60A 5KA C CURVE (TYPE2)MASTERPACT NT06 - NT16 REMOTE OPERATION

Page 13: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Type Description Reference

Pushbutton locking device By padlocks 33897

By Ronis keylocks + 1 lock with 1 key + adaptation kit 47521

BPFE support 2 locks - 2 same keys + adaptation kit 47522

Type Description Reference

Interlocking using cables * 1 adaptation fixture for Masterpact NT fixed 33200

Select 2 adaptation fixtures devices

(1 for each breaker) + 1 set 1 adaptation fixture for Masterpact NT drawout 33201

of cables: devices

1 set of 2 cables 33209

Note: * Can be used with any combination of NT or NW, fixed or drawout devices.

Type Description Reference

Escutcheon and accessories Escutcheon Fixed 33718

Drawout 33857

Note: The Escutcheon and the transparent cover (IP 54) are required to be purchased together if this option is selected.

Type Description Reference

External sensor for earth- Sensor rating 400/1600A 33576leakage protection (TCE) (for Micrologic P and H with 3P devices)

Rectangular sensor for 280 mm x 115 mm 33573earth-leakage protection

Note: * An external sensor is compulsory if a Micrologic 7.0 A / P / H is selected.

Type Description Reference

Pushbutton locking device By padlocks 33897

By Ronis keylocks + 1 lock with 1 key + adaptation kit 47521

BPFE support 2 locks - 2 same keys + adaptation kit 47522

Type Description Reference

Interlocking using cables * 1 adaptation fixture for Masterpact NT fixed 33200

Select 2 adaptation fixtures devices

(1 for each breaker) + 1 set 1 adaptation fixture for Masterpact NT drawout 33201

of cables: devices

1 set of 2 cables 33209

Note: * Can be used with any combination of NT or NW, fixed or drawout devices.

Type Description Reference

Escutcheon and accessories Escutcheon Fixed 33718

Drawout 33857

Note: The Escutcheon and the transparent cover (IP 54) are required to be purchased together if thisoption is selected.

Type Description Reference

External sensor for earth- Sensor rating 400/1600A 33576leakage protection (TCE) (for Micrologic P and H with 3P devices)

Rectangular sensor for 280 mm x 115 mm 33573earth-leakage protection

Note: * The external sensor REF: 33573 is compulsory if a Micrologic 7.0 A / P / H is selected.

Masterpact NT06 - NT16 Accessories for fixed or drawout circuit breakers

C60A 5KA C CURVE (TYPE2)

110

C60A 5KA C CURVE (TYPE2)

1.3

MASTERPACT NT06 - NT16 MECHANICAL INTERLOCKING FOR SOURCE CHANGEOVER

MASTERPACT NT06 - NT16 CIRCUIT BREAKER LOCKING

MASTERPACT NT06 - NT16 OTHER CIRCUIT BREAKER ACCESSORIES

C60A 5KA C CURVE (TYPE2)MASTERPACT NT06 - NT16 ACCESSORIES FOR MICROLOGIC CONTROL UNITS

Page 14: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Type Description Position Poles/Quantity Reference

Interphase barriers Top/Bottom 3P (3 parts) 33648

TypeIcm (kA at Icw (kA

Poles Rating (A) in Reference

220/690V) for 1 sec) (A at 40°C)

HA 75 36 3 630 NT06HA3F

800 NT08HA3F

1000 NT10HA3F

1250 NT12HA3F

1600 NT16HA3F

Description Position Poles/Quantity Reference

Interphase barriers Top/Bottom 3P (3 parts) 33648

TypeIcm (kA at Icw (kA

Poles Rating (A) in Reference

220/690V) for 1 sec) (A at 40°C)

HA 75 36 3 630 NT06HA3F

800 NT08HA3F

1000 NT10HA3F

1250 NT12HA3F

1600 NT16HA3F

Masterpact NT06 - NT16 Fixed switch-disconnectors

A complete Masterpact fixed switch-disconnector device includes:1) the basic switch-disconnector2) top and bottom connections3) top and bottom interphase barriersOptional: * Please contact your local Schneider sales office for assistance1) complete 4 pole switch-disconnectors2) front and vertical connections 3) communication options and various auxiliaries and accessories may also be added. Please refer to the circuit breaker section

111

1.3

MASTERPACT NT06 - NT16 SWITCH-DISCONNECTOR HORIONTALLY REAR CONNECTED

MASTERPACT NT06 - NT16 CONNECTION ACCESSORIES

Page 15: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Type Description Position Poles/Quantity Reference

Interphase barriers - 3P (3 parts) 33768

Type Poles Amp rating Reference

HA 3 630/1250A 33722

1600A 33723

TypeIcm (kA at Icw (kA

PolesRating (A) in

Reference220/690V) for 1 sec) (A at 40°C)

HA 75 36 3 630 NT06HA3D

800 NT08HA3D

1000 NT10HA3D

1250 NT12HA3D

1600 NT16HA3D

Description Position Poles/Quantity Reference

Interphase barriers - 3P (3 parts) 33768

C60A 5KA C CURVE (TYPE2)MASTERPACT NT06 - NT16 CONNECTION ACCESSORIES

Type Poles Amp rating Reference

HA 3 630/1250A 33722

1600A 33723

TypeIcm (kA at Icw (kA

PolesRating (A) in

Reference220/690V) for 1 sec) (A at 40°C)

HA 75 36 3 630 NT06HA3D

800 NT08HA3D

1000 NT10HA3D

1250 NT12HA3D

1600 NT16HA3D

Masterpact NT06 - NT16 Drawout switch-disconnectors

112

1.3

To order a complete Masterpact drawout switch-disconnector device, please select:1) the basic switch-disconnector2) a chassis3) top and bottom connections4) bottom interphase barriersNote: Safety shutters are now supplied standard as part of the chassisOptional: * Please contact your local Schneider sales office for assistance 1) complete 4 pole switch-disconnectors2) front and vertical connections 3) communication options and various auxiliaries and accessories may also be added. Please refer to the circuit breaker section

MASTERPACT NT06 - NT16 SWITCH-DISCONNECTOR HORIZONTALLY REAR CONNECTED

MASTERPACT NT06 - NT16 CHASSIS

Page 16: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference440V) 525V) (A at 40°C)

N1 42 42 3 800 NW08N13F2.0A

1000 NW10N13F2.0A

1250 NW12N13F2.0A

1600 NW16N13F2.0A

H1 65 65 3 800 NW08H13F2.0A

1000 NW10H13F2.0A

1250 NW12H13F2.0A

1600 NW16H13F2.0A

2000 NW20H13F2.0A

2500 NW25H13F2.0A

3200 NW32H13F2.0A

H2 100 85 3 800 NW08H23F2.0A

1000 NW10H23F2.0A

1250 NW12H23F2.0A

1600 NW16H23F2.0A

2000 NW20H23F2.0A

2500 NW25H23F2.0A

3200 NW32H23F2.0A

Note: Optional: Please consult Schneider Electric if neutral required on the right hand side

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference440V) 525V) (A at 40°C)

N1 42 42 3 800 NW08N13F2.0A

1000 NW10N13F2.0A

1250 NW12N13F2.0A

1600 NW16N13F2.0A

H1 65 65 3 800 NW08H13F2.0A

1000 NW10H13F2.0A

1250 NW12H13F2.0A

1600 NW16H13F2.0A

2000 NW20H13F2.0A

2500 NW25H13F2.0A

3200 NW32H13F2.0A

H2 100 85 3 800 NW08H23F2.0A

1000 NW10H23F2.0A

1250 NW12H23F2.0A

1600 NW16H23F2.0A

2000 NW20H23F2.0A

2500 NW25H23F2.0A

3200 NW32H23F2.0A

Note: Optional: Please consult Schneider Electric if neutral required on the right hand side

Masterpact NW08 - NW32 Fixed circuit breakers

113

1.3MASTERPACT NW08 - NW32 COMPLETE HORIZONTALLY REAR CONNECTED CIRCUIT BREAKERWITH MICROLOGIC 2.0A

A complete Masterpact fixed circuit breaker device includes:1) the basic circuit breaker2) a micrologic control unit3) top and bottom connections4) top and bottom interphase barriers5) 4x (OF) ON/OFF indication contacts 6) 1x (SDE) fault trip indication contact Note:* If a Micrologic 7.0 A is selected, it is compulsory to add the external sensor.Optional: * Please contact your local Schneider sales office for assistance1) complete 4 pole circuit breakers2) front and vertical connections 3) communication options and various auxiliaries and accessories may also be added.

Page 17: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference440V) 525V) (A at 40°C)

N1 42 42 3 800 NW08N13F5.0A

1000 NW10N13F5.0A

1250 NW12N13F5.0A

1600 NW16N13F5.0A

H1 65 65 3 800 NW08H13F5.0A

1000 NW10H13F5.0A

1250 NW12H13F5.0A

1600 NW16H13F5.0A

2000 NW20H13F5.0A

2500 NW25H13F5.0A

3200 NW32H13F5.0A

H2 100 85 3 800 NW08H23F5.0A

1000 NW10H23F5.0A

1250 NW12H23F5.0A

1600 NW16H23F5.0A

2000 NW20H23F5.0A

2500 NW25H23F5.0A

3200 NW32H23F5.0A

Note: Optional: Please consult Schneider Electric if neutral required on the right hand side

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference440V) 525V) (A at 40°C)

N1 42 42 3 800 NW08N13F6.0A

1000 NW10N13F6.0A

1250 NW12N13F6.0A

1600 NW16N13F6.0A

H1 65 65 3 800 NW08H13F6.0A

1000 NW10H13F6.0A

1250 NW12H13F6.0A

1600 NW16H13F6.0A

2000 NW20H13F6.0A

2500 NW25H13F6.0A

3200 NW32H13F6.0A

H2 100 85 3 800 NW08H23F6.0A

1000 NW10H23F6.0A

1250 NW12H23F6.0A

1600 NW16H23F6.0A

2000 NW20H23F6.0A

2500 NW25H23F6.0A

3200 NW32H23F6.0A

Note: Optional: Please consult Schneider Electric if neutral required on the right hand side

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference440V) 525V) (A at 40°C)

N1 42 42 3 800 NW08N13F5.0A

1000 NW10N13F5.0A

1250 NW12N13F5.0A

1600 NW16N13F5.0A

H1 65 65 3 800 NW08H13F5.0A

1000 NW10H13F5.0A

1250 NW12H13F5.0A

1600 NW16H13F5.0A

2000 NW20H13F5.0A

2500 NW25H13F5.0A

3200 NW32H13F5.0A

H2 100 85 3 800 NW08H23F5.0A

1000 NW10H23F5.0A

1250 NW12H23F5.0A

1600 NW16H23F5.0A

2000 NW20H23F5.0A

2500 NW25H23F5.0A

3200 NW32H23F5.0A

Note: Optional: Please consult Schneider Electric if neutral required on the right hand side

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference440V) 525V) (A at 40°C)

N1 42 42 3 800 NW08N13F6.0A

1000 NW10N13F6.0A

1250 NW12N13F6.0A

1600 NW16N13F6.0A

H1 65 65 3 800 NW08H13F6.0A

1000 NW10H13F6.0A

1250 NW12H13F6.0A

1600 NW16H13F6.0A

2000 NW20H13F6.0A

2500 NW25H13F6.0A

3200 NW32H13F6.0A

H2 100 85 3 800 NW08H23F6.0A

1000 NW10H23F6.0A

1250 NW12H23F6.0A

1600 NW16H23F6.0A

2000 NW20H23F6.0A

2500 NW25H23F6.0A

3200 NW32H23F6.0A

Note: Optional: Please consult Schneider Electric if neutral required on the right hand side

MASTERPACT NW08 - NW32 COMPLETE HORIZONTALLY REAR CONNECTED CIRCUIT BREAKERWITH MICROLOGIC 5.0A

114

Masterpact NT06 - NT16 Fixed Circuit Breakers

1.3

Masterpact NW08 - NW32 Fixed circuit breakers

MASTERPACT NW08 - NW32 COMPLETE HORIZONTALLY REAR CONNECTED CIRCUIT BREAKWITHMICROLOGIC 6.0A

Page 18: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Type Control Unit Protection Reference

Rear connection Interphase barriers 3P (3 parts) 48599

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference440V) 525V) (A at 40°C)

N1 42 42 3 800 NW08N13F7.0A

1000 NW10N13F7.0A

1250 NW12N13F7.0A

1600 NW16N13F7.0A

H1 65 65 3 800 NW08H13F7.0A

1000 NW10H13F7.0A

1250 NW12H13F7.0A

1600 NW16H13F7.0A

2000 NW20H13F7.0A

2500 NW25H13F7.0A

3200 NW32H13F7.0A

H2 100 85 3 800 NW08H23F7.0A

1000 NW10H23F7.0A

1250 NW12H23F7.0A

1600 NW16H23F7.0A

2000 NW20H23F7.0A

2500 NW25H23F7.0A

3200 NW32H23F7.0A

Note: Optional: Please consult Schneider Electric if neutral required on the right hand side

Type Description Reference

ON/OFF indication contacts Changeover contacts (6A - 240V), 4 supplied Standard(OF) standard

1 additional block of 4 contacts (2 max.) 48198

Fault trip indication contacts Changeover contact (5A - 240V), Standard(SDE) 1 supplied standard

1 additional SDE (5A - 240V) 48200

1 additional low-level SDE 48201

Type Description Reference

ON/OFF indication Changeover contacts (6A - 240V), 4 supplied Standardcontacts (OF) standard

1 additional block of 4 contacts (2 max.) 48198

Fault trip indication Changeover contact (5A - 240V), Standardcontacts (SDE) 1 supplied standard

1 additional SDE (5A - 240V) 48200

1 additional low-level SDE 48201

Type Control Unit Protection Reference

Rear connection Interphase barriers 3P (3 parts) 48599

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference440V) 525V) (A at 40°C)

N1 42 42 3 800 NW08N13F7.0A

1000 NW10N13F7.0A

1250 NW12N13F7.0A

1600 NW16N13F7.0A

H1 65 65 3 800 NW08H13F7.0A

1000 NW10H13F7.0A

1250 NW12H13F7.0A

1600 NW16H13F7.0A

2000 NW20H13F7.0A

2500 NW25H13F7.0A

3200 NW32H13F7.0A

H2 100 85 3 800 NW08H23F7.0A

1000 NW10H23F7.0A

1250 NW12H23F7.0A

1600 NW16H23F7.0A

2000 NW20H23F7.0A

2500 NW25H23F7.0A

3200 NW32H23F7.0A

Note: Optional: Please consult Schneider Electric if neutral required on the right hand side

Masterpact NW08 - NW32 Fixed circuit breakers

115

1.3

MASTERPACT NW08 - NW32 COMPLETE HORIZONTALLY REAR CONNECTED CIRCUIT BREAKERWITH MICROLOGIC 7.0A

MASTERPACT NW08 - NW32 CONNECTION ACCESSORIES

MASTERPACT NW08 - NW32 INDICATION CONTACTS

Page 19: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Type Description Voltage Reference

Remote Gear motor (MCH) AC 48V 48207

ON / OFF 50/60Hz 100-130V 48211

200-240V 48212

250-277V 48213

380-415V 48214

440-480V 48215

DC 24-30V 48206

48-60V 48207

100-130V 48208

200-250V 48209

Instant Standard XF AC 12V DC 47349

voltage (closing 50/60Hz 24-30V DC, 47350

releases voltage or DC 24V AC

release) 48-60V DC, 47351

48V AC

100-130V 47352

200-250V 47353

277V AC 47354

380-480V 47355

AC

MX AC 12V DC 47359

(opening 50/60Hz 24-30V DC, 47360

voltage or DC 24V AC

release) 48-60V DC, 47361

48V AC

100-130V 47362

200-250V 47363

277V AC 47364

380-480V 47365

AC

Ready to close contact 1 changeover contact - 47342(1 max.) PF (5A - 240V)

1 low-level changeover 47343contact (PF)

Electrical pushbutton 1 Electrical closing 48534pushbutton (BPFE)

Instant Standard MN AC 24-30V DC, 47380

voltage (under- 50/60Hz 24V AC

releases voltage or DC 48-60V DC, 47381

release) 48V AC

100-130V 47382

200-250V 47383

380-480V 47385

AC

Type Description Voltage Reference

Remote Gear motor (MCH) AC 48V 48207

ON / OFF 50/60Hz 100-130V 48211

200-240V 48212

250-277V 48213

380-415V 48214

440-480V 48215

DC 24-30V 48206

48-60V 48207

100-130V 48208

200-250V 48209

Instant Standard XF AC 12V DC 47349

voltage (closing 50/60Hz 24-30V DC, 47350

releases voltage or DC 24V AC

release) 48-60V DC, 47351

48V AC

100-130V 47352

200-250V 47353

277V AC 47354

380-480V 47355

AC

MX AC 12V DC 47359

(opening 50/60Hz 24-30V DC, 47360

voltage or DC 24V AC

release) 48-60V DC, 47361

48V AC

100-130V 47362

200-250V 47363

277V AC 47364

380-480V 47365

AC

Ready to close contact 1 changeover contact - 47342(1 max.) PF (5A - 240V)

1 low-level changeover 47343contact (PF)

Electrical pushbutton 1 Electrical closing 48534pushbutton (BPFE)

Instant Standard MN AC 24-30V DC, 47380

voltage (under- 50/60Hz 24V AC

releases voltage or DC 48-60V DC, 47381

release) 48V AC

100-130V 47382

200-250V 47383

380-480V 47385

AC

Masterpact NW08 - NW32 Fixed circuit breakers

116

1.3

MASTERPACT NW08 - NW32 REMOTE OPERATION

Page 20: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference440V) 525V) (A at 40°C)

N1 42 42 3 800 NW08N13D2.0A

1000 NW10N13D2.0A

1250 NW12N13D2.0A

1600 NW16N13D2.0A

H1 65 65 3 800 NW08H13D2.0A

1000 NW10H13D2.0A

1250 NW12H13D2.0A

1600 NW16H13D2.0A

2000 NW20H13D2.0A

2500 NW25H13D2.0A

3200 NW32H13D2.0A

H2 100 85 3 800 NW08H23D2.0A

1000 NW10H23D2.0A

1250 NW12H23D2.0A

1600 NW16H23D2.0A

2000 NW20H23D2.0A

2500 NW25H23D2.0A

3200 NW32H23D2.0A

Note: Optional: Please consult Schneider Electric if neutral required on the right hand side

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference440V) 525V) (A at 40°C)

N1 42 42 3 800 NW08N13D2.0A

1000 NW10N13D2.0A

1250 NW12N13D2.0A

1600 NW16N13D2.0A

H1 65 65 3 800 NW08H13D2.0A

1000 NW10H13D2.0A

1250 NW12H13D2.0A

1600 NW16H13D2.0A

2000 NW20H13D2.0A

2500 NW25H13D2.0A

3200 NW32H13D2.0A

H2 100 85 3 800 NW08H23D2.0A

1000 NW10H23D2.0A

1250 NW12H23D2.0A

1600 NW16H23D2.0A

2000 NW20H23D2.0A

2500 NW25H23D2.0A

3200 NW32H23D2.0A

Note: Optional: Please consult Schneider Electric if neutral required on the right hand side

Masterpact NW08 - NW32 Drawout circuit breakers

117

1.3

A complete Masterpact drawout circuit breaker device includes:1) the basic circuit breaker2) a micrologic control unit3) a chassis4) top and bottom connections5) bottom interphase barriers6) 4x (OF) ON/OFF indication contacts 7) 1x (SDE) fault trip indication contact Note: * Safety shutters are now supplied standard as part of the chassis* If a Micrologic 7.0 A is selected, it is compulsory to add the external sensor.Optional: * Please contact your local Schneider sales office for assistance 1) complete 4 pole circuit breakers2) front and vertical connections 3) communication options and various auxiliaries and accessories may also be added.

MASTERPACT NW08 - NW32 COMPLETE HORIZONTALLY REAR CONNECTED CIRCUIT BREAKERWITH MICROLOGIC 2.0A

Page 21: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference440V) 525V) (A at 40°C)

N1 42 42 3 800 NW08N13D6.0A

1000 NW10N13D6.0A

1250 NW12N13D6.0A

1600 NW16N13D6.0A

H1 65 65 3 800 NW08H13D6.0A

1000 NW10H13D6.0A

1250 NW12H13D6.0A

1600 NW16H13D6.0A

2000 NW20H13D6.0A

2500 NW25H13D6.0A

3200 NW32H13D6.0A

H2 100 85 3 800 NW08H23D6.0A

1000 NW10H23D6.0A

1250 NW12H23D6.0A

1600 NW16H23D6.0A

2000 NW20H23D6.0A

2500 NW25H23D6.0A

3200 NW32H23D6.0A

Note: Optional: Please consult Schneider Electric if neutral required on the right hand side

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference440V) 525V) (A at 40°C)

N1 42 42 3 800 NW08N13D5.0A

1000 NW10N13D5.0A

1250 NW12N13D5.0A

1600 NW16N13D5.0A

H1 65 65 3 800 NW08H13D5.0A

1000 NW10H13D5.0A

1250 NW12H13D2.0A

1600 NW16H13D2.0A

2000 NW20H13D2.0A

2500 NW25H13D2.0A

3200 NW32H13D2.0A

H2 100 85 3 800 NW08H23D2.0A

1000 NW10H23D2.0A

1250 NW12H23D2.0A

1600 NW16H23D2.0A

2000 NW20H23D2.0A

2500 NW25H23D2.0A

3200 NW32H23D2.0A

Note: Optional: Please consult Schneider Electric if neutral required on the right hand side

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference440V) 525V) (A at 40°C)

N1 42 42 3 800 NW08N13D6.0A

1000 NW10N13D6.0A

1250 NW12N13D6.0A

1600 NW16N13D6.0A

H1 65 65 3 800 NW08H13D6.0A

1000 NW10H13D6.0A

1250 NW12H13D6.0A

1600 NW16H13D6.0A

2000 NW20H13D6.0A

2500 NW25H13D6.0A

3200 NW32H13D6.0A

H2 100 85 3 800 NW08H23D6.0A

1000 NW10H23D6.0A

1250 NW12H23D6.0A

1600 NW16H23D6.0A

2000 NW20H23D6.0A

2500 NW25H23D6.0A

3200 NW32H23D6.0A

Note: Optional: Please consult Schneider Electric if neutral required on the right hand side

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference440V) 525V) (A at 40°C)

N1 42 42 3 800 NW08N13D5.0A

1000 NW10N13D5.0A

1250 NW12N13D5.0A

1600 NW16N13D5.0A

H1 65 65 3 800 NW08H13D5.0A

1000 NW10H13D5.0A

1250 NW12H13D5.0A

1600 NW16H13D5.0A

2000 NW20H13D5.0A

2500 NW25H13D5.0A

3200 NW32H13D5.0A

H2 100 85 3 800 NW08H23D5.0A

1000 NW10H23D5.0A

1250 NW12H23D5.0A

1600 NW16H23D5.0A

2000 NW20H23D5.0A

2500 NW25H23D5.0A

3200 NW32H23D5.0A

Note: Optional: Please consult Schneider Electric if neutral required on the right hand side

Masterpact NW08 - NW32 Drawout circuit breakers

118

1.3

MASTERPACT NW08 - NW32 COMPLETE HORIZONTALLY REAR CONNECTED CIRCUIT BREAKERWITH MICROLOGIC 5.0A

MASTERPACT NW08 - NW32 COMPLETE HORIZONTALLY REAR CONNECTED CIRCUIT BREAKERWITH MICROLOGIC 6.0A

Page 22: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Type Poles Amp rating Reference

N1 3 800/1250A 48391

1600A 48392

H1 / H2 3 800/1600A 48392

2000A 48393

2500A 48394

3200A 48395

Type Poles Amp rating Reference

N1 3 800/1250A 48391

1600A 48392

H1 / H2 3 800/1600A 48392

2000A 48393

2500A 48394

3200A 48395

Type Control Unit Protection Reference

Rear connection Interphase barriers 3P/4P (3 parts) 48600

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference440V) 525V) (A at 40°C)

N1 42 42 3 800 NW08N13D7.0A

1000 NW10N13D7.0A

1250 NW12N13D7.0A

1600 NW16N13D7.0A

H1 65 65 3 800 NW08H13D7.0A

1000 NW10H13D7.0A

1250 NW12H13D7.0A

1600 NW16H13D7.0A

2000 NW20H13D7.0A

2500 NW25H13D7.0A

3200 NW32H13D7.0A

H2 100 85 3 800 NW08H23D7.0A

1000 NW10H23D7.0A

1250 NW12H23D7.0A

1600 NW16H23D7.0A

2000 NW20H23D7.0A

2500 NW25H23D7.0A

3200 NW32H23D7.0A

Note: Optional: Please consult Schneider Electric if neutral required on the right hand side

Type Control Unit Protection Reference

Rear connection Interphase barriers 3P/4P (3 parts) 48600

C60A 5KA C CURVE (TYPE2)MASTERPACT NW08 - NW32 CONNECTION ACCESSORIES

TypeIcu (kA at Icu (kA at

PolesRating (A) in

Reference440V) 525V) (A at 40°C)

N1 42 42 3 800 NW08N13D7.0A

1000 NW10N13D7.0A

1250 NW12N13D7.0A

1600 NW16N13D7.0A

H1 65 65 3 800 NW08H13D7.0A

1000 NW10H13D7.0A

1250 NW12H13D7.0A

1600 NW16H13D7.0A

2000 NW20H13D7.0A

2500 NW25H13D7.0A

3200 NW32H13D7.0A

H2 100 85 3 800 NW08H23D7.0A

1000 NW10H23D7.0A

1250 NW12H23D7.0A

1600 NW16H23D7.0A

2000 NW20H23D7.0A

2500 NW25H23D7.0A

3200 NW32H23D7.0A

Note: Optional: Please consult Schneider Electric if neutral required on the right hand side

Masterpact NW08 - NW32 Drawout circuit breakers

119

1.3

MASTERPACT NW08 - NW32 CHASSIS

MASTERPACT NW08 - NW32 COMPLETE HORIZONTALLY REAR CONNECTED CIRCUIT BREAKERWITH MICROLOGIC 7.0A

Page 23: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Type Description Reference

ON/OFF indication contacts Changeover contacts (6A - 240V), 4 supplied Standard

(OF) standard

1 additional block of 4 contacts (Two contacts 48468

maximum)

Combined closed / connected 1 contact (5A - 240V). Eight contacts maximum 48477

contacts for use with 1 low-level contact (Eight contacts maximum) 48478

1 auxiliary contact

Fault trip indication contacts Changeover contact (5A - 240V), Standard

(SDE) 1 supplied standard

1 additional SDE (5A - 240V) 48475

1 additional low-level SDE 48476

Programmable contacts for 2 contacts (M2C) (5A - 240V) 48382

Micrologic P & H only 6 changeover contacts (M6C) (5A - 240V) 48383

Carriage switches (connected/ 1 connected position contact (3 max.) 33751

disconnected/test position) 1 test position contact (3 max.) 33752

Changeover contacts 1 disconnected position contact (3 max.) 33753

(8A - 240V):

Carriage switches (connected/ 1 connected position contact (3 max.) 33754

disconnected/test position) 1 test position contact (3 max.) 33755

and/or low-level changeover 1 disconnected position contact (3 max.) 33756

contacts: Actuator for additional carriage switches 48560

Auxiliary terminals for chassis 3 wire terminals (30 parts) 47898

only 6 wire terminals (10 parts) 47899

Jumpers (10 parts) 47900

Type Description Reference

Disconnected By padlocks VCPO Standard

position By Ronis 1 lock with 1 key + adaptation kit 48572

locking keylocks 2 locks - 2 same keys + adaptation kit 48573

2 locks - 2 different keys + adaptation kit 48574

Door interlock (1 part) Right-hand side of chassis (VPECD) 48579

Left-hand side of chassis (VPECG) 48580

Racking interlock (VPOC) 48582

Racking interlock between crank and OFF pushbutton 48585

Automatic spring discharge before breaker removal 48554

Breaker mismatch protection (VDC) 33767

Type Description Reference

ON/OFF indication contacts Changeover contacts (6A - 240V), 4 supplied Standard

(OF) standard

1 additional block of 4 contacts (Two contacts 48468

maximum)

Combined closed / connected 1 contact (5A - 240V). Eight contacts maximum 48477

contacts for use with 1 low-level contact (Eight contacts maximum) 48478

1 auxiliary contact

Fault trip indication contacts Changeover contact (5A - 240V), Standard

(SDE) 1 supplied standard

1 additional SDE (5A - 240V) 48475

1 additional low-level SDE 48476

Programmable contacts for 2 contacts (M2C) (5A - 240V) 48382

Micrologic P & H only 6 changeover contacts (M6C) (5A - 240V) 48383

Carriage switches (connected/ 1 connected position contact (3 max.) 33751

disconnected/test position) 1 test position contact (3 max.) 33752

Changeover contacts 1 disconnected position contact (3 max.) 33753

(8A - 240V):

Carriage switches (connected/ 1 connected position contact (3 max.) 33754

disconnected/test position) 1 test position contact (3 max.) 33755

and/or low-level changeover 1 disconnected position contact (3 max.) 33756

contacts: Actuator for additional carriage switches 48560

Auxiliary terminals for chassis 3 wire terminals (30 parts) 47898

only 6 wire terminals (10 parts) 47899

Jumpers (10 parts) 47900

Type Description Reference

Disconnected By padlocks VCPO Standard

position By Ronis 1 lock with 1 key + adaptation kit 48572

locking keylocks 2 locks - 2 same keys + adaptation kit 48573

2 locks - 2 different keys + adaptation kit 48574

Door interlock (1 part) Right-hand side of chassis (VPECD) 48579

Left-hand side of chassis (VPECG) 48580

Racking interlock (VPOC) 48582

Racking interlock between crank and OFF pushbutton 48585

Automatic spring discharge before breaker removal 48554

Breaker mismatch protection (VDC) 33767

Masterpact NW08 - NW32 Drawout circuit breakers

120

1.3

C60A 5KA C CURVE (TYPE2)MASTERPACT NW08 - NW32 CHASSIS LOCKING

MASTERPACT NW08 - NW32 INDICATION CONTACTS

Page 24: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Type Description Voltage Reference

Remote Gear motor (MCH) AC 48V 48522

ON / OFF 50/60Hz 100-130V 48526

200-240V 48527

250-277V 48528

380-415V 48529

440-480V 48530

DC 24-30V 48521

48-60V 48522

100-130V 48523

200-250V 48524

Instant. Standard XF AC 12V DC 48480

voltage (closing 50/60Hz 24-30V DC, 48481

releases voltage or DC 24V AC

release) 48-60V DC, 48482

48V AC

100-130V 48483

200-250V 48484

277V AC 48485

380-480V 48486

AC

MX AC 12V DC 48490

(opening 50/60Hz 24-30V DC, 48491

voltage or DC 24V AC

release) 48-60V DC, 48492

48V AC

100-130V 48493

200-250V 48494

277V AC 48495

380-480V 48496

AC

Ready to close contact 1 changeover contact (1 max.) 48469

- PF (5A - 240V)

1 low-level changeover contact (PF) 48470

Instant. MN AC 24-30V DC, 48501

voltage (under- 50/60Hz 24V AC 48502

releases voltage or DC 48-60V DC,

release) 48V AC

100-130V 48503

200-250V 48504

380-480V 48506

AC

Type Description Voltage Reference

Remote Gear motor (MCH) AC 48V 48522

ON / OFF 50/60Hz 100-130V 48526

200-240V 48527

250-277V 48528

380-415V 48529

440-480V 48530

DC 24-30V 48521

48-60V 48522

100-130V 48523

200-250V 48524

Instant. Standard XF AC 12V DC 48480

voltage (closing 50/60Hz 24-30V DC, 48481

releases voltage or DC 24V AC

release) 48-60V DC, 48482

48V AC

100-130V 48483

200-250V 48484

277V AC 48485

380-480V 48486

AC

MX AC 12V DC 48490

(opening 50/60Hz 24-30V DC, 48491

voltage or DC 24V AC

release) 48-60V DC, 48492

48V AC

100-130V 48493

200-250V 48494

277V AC 48495

380-480V 48496

AC

Ready to close contact 1 changeover contact (1 max.) 48469

- PF (5A - 240V)

1 low-level changeover contact (PF) 48470

Instant. MN AC 24-30V DC, 48501

voltage (under- 50/60Hz 24V AC 48502

releases voltage or DC 48-60V DC,

release) 48V AC

100-130V 48503

200-250V 48504

380-480V 48506

AC

Masterpact NW08 - NW32 Drawout circuit breakers

121

1.3

C60A 5KA C CURVE (TYPE2)MASTERPACT NW08 - NW32 REMOTE OPERATION

Page 25: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Type Description Reference

Interlocking of 2 devices 1 adaptation fixture for Masterpact NW fixed 47926

using cables ** devices/

Select 2 adaptation sets 1 adaptation fixture for Masterpact NW drawout

(1 for each breaker devices

+ 1 set of cables): 1 set of 2 cables 33209

Interlocking of 3 devices 3 sources, only 1 device closed, fixed or drawout 48610

using cables devices

Select 3 adaptation sets 2 sources + 1 coupling, fixed or drawout devices 48609

(including 3 adaptation 2 normal + 1 replacement source, fixed or 48608

fixtures + cables): drawout devices

Note: * Can be used with 1 NW fixed + 1 NW drawout. ** Can be used with any combination of NT or NW fixed or drawout devices.

Type Description Reference

Escutcheon and accessories Escutcheon Fixed 48601

Drawout 48603

Transparent cover (IP 54) Drawout 48604

Escutcheon blanking plate Fixed / Drawout 48605

Note: The Escutcheon and the transparent cover (IP 54) are required to be purchased together if this option is selected.

Type Description Reference

Pushbutton locking device By padlocks 48536

OFF By Ronis keylocks 1 lock with 1 key + adaptation kit 48549position

2 locks - 2 same keys + adaptation kit 48550locking

2 locks - 2 different keys + adaptation kit 48551

Type Description Reference

Interlocking of 2 devices 1 adaptation fixture for Masterpact NW fixed 47926

using cables ** devices/

Select 2 adaptation sets 1 adaptation fixture for Masterpact NW drawout

(1 for each breaker devices

+ 1 set of cables): 1 set of 2 cables 33209

Interlocking of 3 devices 3 sources, only 1 device closed, fixed or drawout 48610

using cables devices

Select 3 adaptation sets 2 sources + 1 coupling, fixed or drawout devices 48609

(including 3 adaptation 2 normal + 1 replacement source, fixed or 48608

fixtures + cables): drawout devices

Note: * Can be used with 1 NW fixed + 1 NW drawout. ** Can be used with any combination of NT or NW fixed or drawout devices.

Type Description Reference

Escutcheon and accessories Escutcheon Fixed 48601

Drawout 48603

Transparent cover (IP 54) Drawout 48604

Escutcheon blanking plate Fixed / Drawout 48605

Note: The Escutcheon and the transparent cover (IP 54) are required to be purchased together if thisoption is selected.

Type Description Reference

Pushbutton locking device By padlocks 48536

OFF By Ronis keylocks 1 lock with 1 key + adaptation kit 48549position

2 locks - 2 same keys + adaptation kit 48550locking

2 locks - 2 different keys + adaptation kit 48551

Masterpact NW08 - NW32 Accessories for fixed or drawout circuit breakers

C60A 5KA C CURVE (TYPE2)

122

C60A 5KA C CURVE (TYPE2)

1.3

MASTERPACT NW08 - NW32 MECHANICAL INTERLOCKING FOR SOURCE CHANGEOVER

MASTERPACT NW08 - NW32 CIRCUIT BREAKER LOCKING

MASTERPACT NW08 - NW32 OTHER CIRCUIT BREAKER ACCESSORIES

Page 26: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Type Description Reference

External sensor for earth- Sensor rating 400/2000A 34035

leakage protection (TCE) Sensor rating 1000/4000A 34036

Rectangular sensor for 470 mm x 160 mm (In. Max 400A) 33574earth-leakage protection

Note: * An external sensor is compulsory if a Micrologic 7.0 A / P / H is selected.

Description Reference

1 complete assembly for Masterpact NW fixed or drawout devices 48614

Type Description Reference

External sensor for earth- Sensor rating 400/2000A 34035

leakage protection (TCE) Sensor rating 1000/4000A 34036

Rectangular sensor for 470 mm x 160 mm (In. Max 400A) 33574earth-leakage protection

Note: * The external sensor REF: 33574 is compulsory if a Micrologic 7.0 A / P / H is selected.

Description Reference

1 complete assembly for Masterpact NW fixed or drawout devices 48614

Masterpact NW08 - NW32 Accessories for fixed or drawout circuit breakers

123

1.3

MASTERPACT NW08 - NW32 CABLE-TYPE DOOR INTERLOCK

C60A 5KA C CURVE (TYPE2)MASTERPACT NW08 - NW32 ACCESSORIES FOR MICROLOGIC CONTROL UNITS

Page 27: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Type Description Poles/Quantity Reference

Rear connection Interphase barriers 3P/4P (3 parts) 48599

accessories Brackets for mounting on a backplate 2 Parts 47829

TypeIcm (kA at Icw (kA

PolesIn Rating

Reference220/690V) for 1 sec) (A at 40°C) (A)

NA 88 42 3 800 800 NW08NA3F

1000 1000 NW10NA3F

1250 1250 NW12NA3F

1600 1600 NW16NA3F

HA 105 50 3 800 800 NW08HA3F

1000 1000 NW10HA3F

1250 1250 NW12HA3F

1600 1600 NW16HA3F

2000 2000 NW20HA3F

Type Description Poles/Quantity Reference

Rear connection Interphase barriers 3P/4P (3 parts) 48599

accessories Brackets for mounting on a backplate 2 Parts 47829

TypeIcm (kA at Icw (kA

PolesIn Rating

Reference220/690V) for 1 sec) (A at 40°C) (A)

NA 88 42 3 800 800 NW08NA3F

1000 1000 NW10NA3F

1250 1250 NW12NA3F

1600 1600 NW16NA3F

HA 105 50 3 800 800 NW08HA3F

1000 1000 NW10HA3F

1250 1250 NW12HA3F

1600 1600 NW16HA3F

2000 2000 NW20HA3F

Masterpact NW08 - NW20 Fixed switch-disconnectors

124

1.3

A complete Masterpact fixed switch-disconnector device includes:1) the basic switch-disconnector2) top and bottom connections3) top and bottom interphase barriersOptional: * Please contact your local Schneider sales office for assistance 1) complete 4 pole switch-disconnectors2) front and vertical connections3) communication options and various auxiliaries and accessories may also be added. Please refer to the circuit breaker section

MASTERPACT NW08 - NW20 SWITCH-DISCONNECTOR HORIZONTALLY REAR CONNECTED

MASTERPACT NW08 - NW20 CONNECTION ACCESSORIES

Page 28: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Type Description Position Poles/Quantity Reference

Rear connection Interphase barriers - 3P/4P (3 parts) 48600

accessories

Type Poles Amp rating Reference

NA 3 800/1250A 48391

NA/HA 3 800/1600A 48392

HA 3 2000A 48393

TypeIcm (kA at Icw (kA

PolesIn Rating

Reference220/690V) for 1 sec) (A at 40°C) (A)

NA 88 42 3 800 800 NW08NA3D

1000 1000 NW10NA3D

1250 1250 NW12NA3D

1600 1600 NW16NA3D

HA 105 50 3 800 800 NW08HA3D

1000 1000 NW10HA3D

1250 1250 NW12HA3D

1600 1600 NW16HA3D

2000 2000 NW20HA3D

Type Description Position Poles/Quantity Reference

Rear connection Interphase barriers - 3P/4P (3 parts) 48600

accessories

Type Poles Amp rating Reference

NA 3 800/1250A 48391

NA/HA 3 800/1600A 48392

HA 3 2000A 48393

TypeIcm (kA at Icw (kA

PolesIn Rating

Reference220/690V) for 1 sec) (A at 40°C) (A)

NA 88 42 3 800 800 NW08NA3D

1000 1000 NW10NA3D

1250 1250 NW12NA3D

1600 1600 NW16NA3D

HA 105 50 3 800 800 NW08HA3D

1000 1000 NW10HA3D

1250 1250 NW12HA3D

1600 1600 NW16HA3D

2000 2000 NW20HA3D

125

1.3

Masterpact NW08 – NW20 Drawout switch-disconnectors

A complete Masterpact drawout switch-disconnector device includes:1) the basic switch-disconnector2) a chassis3) top and bottom connections4) bottom interphase barriersNote:Safety shutters are now supplied standard as part of the chassisOptional: * Please contact your local Schneider sales office for assistance1) complete 4 pole switch-disconnectors2) front and vertical connections 3) communication options and various auxiliaries and accessories may also be added. Please refer to the circuit breaker section

MASTERPACT NW08 - NW20 SWITCH-DISCONNECTOR HORIZONTALLY REAR CONNECTED

MASTERPACT NW08 - NW20 CHASSIS

MASTERPACT NW08 - NW20 CONNECTION ACCESSORIES

Page 29: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Voltage and Frquency Type Reference

110/127V AC 50/60 Hz ACP + control unit UA * 29448

Plate ACP 29447

Control unit UA 29446

220/240V AC 50/60 Hz ACP + control unit UA * 29472

Plate ACP 29363

Control unit UA 29378

380/415V AC 50/60 Hz ACP + control unit UA * 29473

or 480V 60 Hz Plate ACP 29364

Control unit UA 29380

Note: * The supply voltages of the BA/UA controller, ACP plate, IVE unit and circuit breaker operating mechanism must be identical whatever the type of source-changeover system. Please make sure of this when placing orders.

Voltage and Frquency Type Reference

220/240V AC 50/60 Hz ACP + control unit BA * 29470

Plate ACP 29363

Control unit BA 29376

380/415V AC 50/60 Hz ACP + control unit BA * 29471

or 480V 60 Hz Plate ACP 29364

Control unit BA 29377

Note: * The supply voltages of the BA/UA controller, ACP plate, IVE unit and circuit breaker operating mechanism must be identical whatever the type of source-changeover system. Please make sure of this when placing orders.

Voltage and Frequency Description Reference

48/415V AC 50/60 Hz or For 2 devices 29352440V 60 Hz

48/415V AC 50/60 Hz Wiring kit for connection of 2 fixed/drawout 54655or 440V 60 Hz devices to the IVE unit

Voltage and Frequency Description Reference

48/415V AC 50/60 Hz or For 2 devices 29352440V 60 Hz

48/415V AC 50/60 Hz Wiring kit for connection of 2 fixed/drawout 54655or 440V 60 Hz devices to the IVE unit

Voltage and Frquency Type Reference

220/240V AC 50/60 Hz ACP + control unit BA * 29470

Plate ACP 29363

Control unit BA 29376

380/415V AC 50/60 Hz ACP + control unit BA * 29471

or 480V 60 Hz Plate ACP 29364

Control unit BA 29377

Note: * The supply voltages of the BA/UA controller, ACP plate, IVE unit and circuit breaker operatingmechanism must be identical whatever the type of source-changeover system. Please make sure of this whenplacing orders.

Voltage and Frquency Type Reference

110/127V AC 50/60 Hz ACP + control unit UA * 29448

Plate ACP 29447

Control unit UA 29446

220/240V AC 50/60 Hz ACP + control unit UA * 29472

Plate ACP 29363

Control unit UA 29378

380/415V AC 50/60 Hz ACP + control unit UA * 29473

or 480V 60 Hz Plate ACP 29364

Control unit UA 29380

Note: * The supply voltages of the BA/UA controller, ACP plate, IVE unit and circuit breaker operatingmechanism must be identical whatever the type of source-changeover system. Please make sure of this whenplacing orders.

Masterpact NT and NW Source-changeover systems

126

1.3

The automatic-control option includes:1) IVE electrical-interlocking unit2) ACP auxiliaries control plate3) BA or UA controller, depending on the required functions4) UA/BA adapter kit.Note:The circuit breaker auxiliaries (MCH, MX, XF) and the automatic control components (IVE, ACP, UA or BA) must have the same voltages. Please make sure of this when placing orders.

MASTERPACT NT AND NW - IVE ELECTRICAL-INTERLOCKING UNIT

MASTERPACT NT AND NW ASSOCIATED CONTROLLER

MASTERPACT NT AND NW - BA CONTROL UNIT OPTION

MASTERPACT NT AND NW - UA CONTROL UNIT OPTION

Page 30: COMPLETE COVER 08 -  · PDF fileMICROLOGIC 5.0A CONTROL UNIT A complete Masterpact fixed circuit breaker device includes: 1) the basic circuit breaker 2) a micrologic control unit

Voltage and Frquency Type Reference

220/240V AC 50/60 Hz ACP + control unit UA150 * 29474

(communication option)

Plate ACP 29363

Control unit UA150 29379

380/415V AC 50/60 Hz ACP + control unit UA150 *

or 480V 60 Hz (communication option) 29475

Plate ACP 29364

Control unit UA150 29381

Note: * The supply voltages of the BA/UA controller, ACP plate, IVE unit and circuit breaker operating mechanism must be identical whatever the type of source-changeover system. Please make sure of this when placing orders.

Voltage and Frquency Type Reference

220/240V AC 50/60 Hz ACP + control unit UA150 * 29474

(communication option)

Plate ACP 29363

Control unit UA150 29379

380/415V AC 50/60 Hz ACP + control unit UA150 *

or 480V 60 Hz (communication option) 29475

Plate ACP 29364

Control unit UA150 29381

Note: * The supply voltages of the BA/UA controller, ACP plate, IVE unit and circuit breaker operatingmechanism must be identical whatever the type of source-changeover system. Please make sure of this whenplacing orders.

Masterpact NT and NW Source-changeover systems

127

1.3

MASTERPACT NT AND NW - UA150 CONTROL UNIT OPTION (COMMUNICATION)