Т8 for Brocade Data Center Ready Compatibility Test Report T8 Page 1 Compatibility Test Report: SAN Extension Т8 VOLGA with MS-100E-T10 card (with additional tests) Document Revision: 1.4 Test completion date: 15/09/2016 Prepared by: Sokolov Sergey

Transcript of Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits...

Page 1: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 1

Compatibility Test Report: SAN Extension

Т8 VOLGA with MS-100E-T10 card

(with additional tests)

Document Revision: 1.4

Test completion date: 15/09/2016

Prepared by: Sokolov Sergey

Page 2: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 2

© 2016 T8 LLC. All Rights Reserved.

All other brands, products, or service names are or may be trademarks or service marks of, and are used

to identify, products or services of their respective owners.

Notice: T8 reserves the right to make changes to this document at any time, without notice, and assumes

no responsibility for its use.

Page 3: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 3

1 INTRODUCTION

1.1 Introduction

This report captures the results of the test performed for compatibility with the T8 VOLGA DWDM

system and MS-100E-T10 card.

This document covers the following areas:

Product & Technology Overview

Test Methodology

Configurations Tested

Test Procedures

Test Bed Data & Test Results

Page 4: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 4

2 PRODUCT & TECHNOLOGY OVERVIEW

The Volga multiservice DWDM platform family provides increased network flexibility and operational

automation through zero-touch, transparent photonic networking. Photonic networks use simplified and

accelerated operations to transform wavelength division multiplexing (WDM) into true transport

networking with advanced flexibility, performance, automation, and integration.

Volga multiservice DWDM platform family includes the following:

• Universal slot-based shelves:

– Volga V10 Shelf

– Volga V6 Shelf

– Volga V3 Shelf

• Volga V1 Edge device (1 RU)

The Volga V10 Shelf supports:

• 13 full height application cards

• 1 equipment controllers (CU)

• 2 redundant power supplies cards (DC or AC)

• 1 fan tray

The Volga V6 Shelf supports:

• 7 full height application cards

• 1 equipment controllers (CU)

• 2 redundant power supplies cards (DC or AC)

• 1 fan tray

The Volga V3 Shelf supports:

• 3 full height application cards

• 1 equipment controllers (CU)

• 2 redundant power supplies cards (DC or AC)

• 1 fan tray

The Volga V1 Edge device (1 RU) supports:

• 1 non replaceable full height application cards

• 1 equipment controllers (CU)

• 2 redundant DС power supplies cards

• 1 fan tray

The testing with Brocade systems was conducted on the Volga V6 Shelf that uses the same software

releases as the other Volga multiservice DWDM platforms.

Page 5: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 5

Volga multiservice platform

The Volga multiservice DWDM platform supports channel speed up to 200 Gbit/s. The Volga chassis can

be installed in 19 or 21 inch telecommunication racks.

Transponders and aggregators from 2,5G to 200G

Optic amplifiers: EDFA, RAMAN and hybrid EDFA+RAMAN

ROADM: WSS 1×1, 1×2, 1×4, 1×9

Chassis depths — 300 mm

The Volga multiservice DWDM platform key features

I. Transmission up to 96 DWDM channels of up to 100 Gbit/s each or 48 up to 200Gbit/s. Client

interfaces:

400G: 100G Ethernet

100G: 100G Ethernet

40G: STM-256, OTU3, 40G Ethernet

10G: 10G Ethernet, STM-64, OTU2, 4/8/10GFC

≤2,5G: 1G Ethernet, STM-1/4/16, OTU1

II. Due to using of WSS ROADM 1×2, 1×4, 1×9 and different types of aggregators and path-protection

cards the Volga platform perfectly fits for constructing DWDM networks of different topologies with

1+1 protection, both ring and mesh. High speed optical end electronic switches, powerful digital

signal processor in 100G transponders make possible to build redundant links with very fast

reconfiguration

III. Low-noise erbium-doped fiber amplifiers (EDFA), Raman amplifiers (RAMAN) with a power of up

to 33 dBm, remote optically pumped amplifiers (ROPA), hybrid amplifiers EDFA + RAMAN

IV. Enables controlling all nodes at the network map with a color-coded indication. The graphical

framework Fractal and the built-in Web-server significantly simplify operations on remote

configuring of the Volga platform.

V. Doubled power units: DC 36–72 or AC 220 V. Power consumption no more than 1600 W.

Page 6: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 6

MS-100E-T10 aggregating transponder

Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC

Transmits 10 client signals of 10GE, STM-64, OTU2, 8/10 GFC

Service channel ESC in line interface

Soft-FEC 15% error correction algorithm

Coherent DP-QPSK modulation format

Reconfigurable in C-band laser

Up to 96 channels in accordance with 50 GHz wavelength channel plan

Automatic dispersion correction up to ± 125000 ps/nm

OSNRt from 11 dB (0.1 nm, BER = 10 -12)

Aggregating transponder (muxponder) combines 10×10 Gbit/s client channels and transmits them in a

DWDM channel. The MS-100E-T10 executes 3R regeneration, converts data into the OTN OTU4 format

and uses the powerful Soft-FEC error correction algorithm.

The MS-100E-T10 transfers data at a stabilized according to ITU-T 50 GHz. The laser with a

reconfigurable according to ITU-T 50 GHz enables organizing up to 96 DWDM channels.

Page 7: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 7

Optical characteristics

Parameter MS-100E-T10 MS-100E-Т10-SH

Line interface, line bit rate / payload OTU4, 120 / 10*10 Gbit/s

Client interfaces’ standards 10GE, STM-64, OTU2, 8/10 GFC

Output power - 5 ... 0 dBm - 15 ... 1 dBm

Operational wavelength range of the transmitter 1528.7–1567.1 nm

Receiver sensitivity (BER=10-12) -18 dBm -21 dBm

Receiver overload (BER=10-12) 0 dBm

Automatic dispersion correction up to ± 70/125 ns/nm up to ± 22 ns/nm

OSNRT (0,1 nm, BER=10-12)

11 dB (Soft-FEC 20%)

12.5 dB (Soft-FEC

15%)

14.5 dB (Soft-FEC

15%)

Power consumption ≤165 W ≤125 W

Page 8: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 8

3 TEST METHODOLOGY

Begin by identifying the objectives, functionality, and interface requirements of the Device Under Test

(DUT), paying particular attention to the areas that relate directly to its interface with the Brocade

product.

• For a DUT with a Fibre Channel (FC) interface, start by testing a single DUT interface port for correct

and consistent initialization of the port on selected Brocade switches.

• Perform login testing to verify correct speed negotiation, link initialization, fabric login, name server

registration, state change registration, and acknowledgements. Introduce errors, such as cable pulls and

switch resets, during the login.

• Next, perform target discovery and I/O traffic. Introduce errors to test these areas: monitoring of data

corruption, I/O stoppage, and throughput changes.

• Introduce the DUT into a larger configuration consisting of multiple Brocade switches, storage systems,

and host types. Test relevant features and functionality of the DUT and compatibility of the DUT with the

Brocade product. Add multiple host OS and storage LUNs as appropriate.

Introduce errors, such as Inter-Switch Link (ISL) toggling and principal switch reset, to verify stability of

the DUT.

• Run traffic for longer periods to check consistent I/O throughput and sustainability.

Page 9: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 9

4 CONFIGURATIONS TESTED

The following sections describe and illustrate topologies used in testing.

4.1 Flat-fabric Topologies

Flat-fabric topologies are connected through the DUT using 8GFC. Switches tested should merge into a

single unified fabric.

Figure 1. Networked Solutions (including MAN/WAN) test configuration.

Page 10: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 10

5 TEST PROCEDURES

5.7 Networked Solutions (including MAN/WAN) Tests.

5.7.1 SAN Extension Tests. VC_RDY MODE.

The test configuration consists of two switches interconnected by the DUT and separated by a long haul

MAN/WAN network.

The long haul network – DWDM 70 km.

Distance (70 km) simulated as a real production scenario.

Host (server Oracle M6-32) and Target (Disk array HP P9500) connect to Brocade DCX 8510. Ports 4/46

and 4/47 Brocade DCX 8510 connect to port Client 4 and port Client 5 MS-100E-T10 card. Ports Line 1

both MS-100E-T10 cards connect to DWDM line 70 km.

Host

Brocade DCX 8510#1

MS-100EDUT #1

Port #0

Port Client #4Client #5 MS-100E

DUT #2

Port Line

DWDM 70 km

Port LinePort4/464/47 Target

Brocade DCX 8510#1

Port #0

Port Client #4Client #5

Port4/464/47

5.7.1.1 E-Port Disable/Enable Test

Objective: To verify that the fabric can form correctly over the long distance link when the link port is

disabled and enabled.

Configuration: 1. Configure per diagram as shown in configuration 6.

Test Steps:

1. Execute a command to disable, e.g. portDisable <port#>, an E_Port connecting the two switches.

2. Fabric reconfiguration should result and the switches should be segmented.

3. Verify that the E_Port connection is offline from switch info., e.g. switchShow , on both switches.

Т8 Commentary: Port 4/46 and Port 4/47 DCX 8510 #1 are disable. E_Port connection is offline.

Page 11: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 11

Т8 Commentary: Port 4/46 and Port 4/47 DCX 8510 #2 are out of sync. E_Port connection is

offline.

4. Verify that two individual fabrics exist, each containing a single switch, e.g. fabricShow , on both

switches.

Т8 Commentary: Two individual fabrics exist, each containing a single switch.

Т8 Commentary: Two individual fabrics exist, each containing a single switch.

5. Merge the switches by re-enable the E-port, e.g. portEnable <port#>

6. Verify E_Port is online on both switches, e.g. switchShow.

Т8 Commentary: Port 4/46 and Port 4/47 DCX 8510 #1 are enable. E_Port connection is online.

Page 12: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 12

Т8 Commentary: Port 4/46 and Port 4/47 DCX 8510 #1 are in sync. E_Port connection is online.

7. Verify the fabric has successfully merged, e.g. fabricShow on each switch. Two switch entries should

exist.

Т8 Commentary: fabric has successfully merged. Two switch entries exist.

Т8 Commentary: fabric has successfully merged. Two switch entries exist.

Results:

All of the following criteria PASS.

Page 13: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 13

5.7.1.2 E-Port Cable Disconnect/Reconnect Test

Objective: To verify that the fabric can form correctly over the long distance link when the link port is

disconnected then reconnected.

Configuration: 1. Configure per diagram as shown in configuration 6.

Test Steps:

1. Disconnect the FC cable from one switch.

2. Fabric reconfiguration should result and the switches should be segmented.

3. Verify that the E_Port connection is offline from switch info., e.g. switchShow on both switches

There is no power on Port 4/46 and Port 4/47 cable’s disconnection.

Т8 Commentary: There is no synchronization on Port 4/46 and Port 4/47 cable’s disconnection.

E_Port connection is offline.

4. Verify that two individual fabrics exist, each containing a single switch, e.g. fabricShow on both

switches.

Т8 Commentary: Two individual fabrics exist, each containing a single switch.

Page 14: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 14

Т8 Commentary: Two individual fabrics exist, each containing a single switch.

5. Merge the switches by re-connecting the cable.

6. Verify the E_Port is online on both switches, e.g. switchShow.

Т8 Commentary: There is synchronization on Port 4/46 and Port 4/47 cable’s connection. E_Port

connection is online.

Т8 Commentary: There is synchronization on Port 4/46 and Port 4/47 cable’s connection. E_Port

connection is online.

7. Verify the fabric has successfully merged, e.g. fabricShow on each switch. Two switch entries should

exist.

Т8 Commentary: fabric has successfully merged. Two switch entries exist.

Page 15: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 15

Т8 Commentary: fabric has successfully merged. Two switch entries exist.

Results: All of the following criteria PASS.

Page 16: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 16

5.7.1.3 Long Haul Network Failure (No Redundancy)

Objective: To verify that the fabric can form correctly over the long distance link after a network failure.

Configuration: 1. Configure per diagram as shown in configuration 6.

Test Steps:

1. Disable the long haul network via cable disconnect.

Т8 Commentary: Disable the long haul network via MS-100E-T10 card Port Line cable

disconnect.

Host

Brocade DCX 8510#1

MS-100EDUT #1

Port #0

Port Client #4Client #5 MS-100E

DUT #2

Port Line

DWDM 70 km

Port LinePort4/464/47 Target

Brocade DCX 8510#1

Port #0

Port Client #4Client #5

Port4/464/47

2. Verify that the E_Port connection is offline, e.g. switchShow, on both switches

Т8 Commentary: There is no power on Port 4/46 and Port 4/47 after cable’s disconnection.

E_Port connection is offline.

Т8 Commentary: There is no synchronization on Port 4/46 and Port 4/47 cable’s disconnection.

E_Port connection is offline.

Page 17: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 17

3. Verify that two individual fabrics exist, each containing a single switch, e.g. fabricShow on both

switches.

Т8 Commentary: Two individual fabrics exist, each containing a single switch.

Т8 Commentary: Two individual fabrics exist, each containing a single switch.

4. Merge the switches by re-enabling the long haul port.

Т8 Commentary: Enable the long haul network via TD-10E card Port Line #1 cable connect.

Host

Brocade DCX 8510#1

MS-100EDUT #1

Port #0

Port Client #4Client #5 MS-100E

DUT #2

Port Line

DWDM 70 km

Port LinePort4/464/47 Target

Brocade DCX 8510#1

Port #0

Port Client #4Client #5

Port4/464/47

5. Execute switchShow and verify the E_Port is online on both switches

Т8 Commentary: There is power on Port 4/46 and Port 4/47 after cable connection. E_Port

connection is online.

Т8 Commentary: There is synchronization on Port 4/46 and Port 4/47 after cable connection.

E_Port connection is online.

Page 18: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 18

6. Verify the fabric has successfully merged, e.g. fabricShow on each switch. Two switch entries should

exist.

Т8 Commentary: fabric has successfully merged. Two switch entries exist.

Т8 Commentary: fabric has successfully merged. Two switch entries exist.

Results:

All of the following criteria PASS.

Page 19: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 19

5.7.1.5 Switch Reboot Test

Objective: To verify that the fabric can form correctly over the long distance link when a switch is reset.

ConfigurationConfigure per diagram as shown in configuration 6.

Test Steps:

1. Reboot one switch, e.g. fastboot.

2. Verify that the E_Port connection is offline on the remote switch, e.g. switchShow.

Т8 Commentary: Two individual fabrics exist, each containing a single switch.

Т8 Commentary: Port 4/46 and Port 4/47 DCX 8510 #1 are out of sync. E_Port connection is

offline.

3. After the rebooted switch is again online, verify that the E_Port performs link initialization and

the fabric merges, e.g. switchShow and fabricShow, on both switches.

Т8 Commentary: fabric has successfully merged. Two switch entries exist.

Page 20: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 20

Т8 Commentary: Port 4/46 and Port 4/47 DCX 8510 #1 are in sync. E_Port connection is online.

Т8 Commentary: fabric has successfully merged. Two switch entries exist.

Т8 Commentary: Port 4/46 and Port 4/47 DCX 8510 #2 are in sync. E_Port connection is online.

Results: All of the following criteria PASS.

Page 21: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 21

5.7.1.6 DUT Reset Test

Objective: To verify that the fabric can form correctly over the long distance link when the DUT is reset.

Configuration: 1. Configure per diagram as shown in configuration 6.

Test Steps:

1. Reboot one of the DUT devices via power cycle or management interface.

2. Verify that the E_Port connection is offline on the remote switch, e.g. switchShow.

Т8 Commentary: Т8 Commentary: There is no power on Port 4/46 and Port 4/47 during DUT

reset. E_Port connection is offline.

Т8 Commentary: Two individual fabrics exist, each containing a single switch.

Т8 Commentary: There is no synchronization on Port 4/46 and Port 4/47 during DUT reset. E_Port

connection is offline.

Page 22: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 22

Т8 Commentary: Two individual fabrics exist, each containing a single switch.

3.After the rebooted switch is again online, verify that the E_Port performs link initialization and the

fabric merges, e.g. switchShow and fabricShow, on both switches.

Т8 Commentary: There is power on Port 4/46 and Port 4/47 after DUT reset. E_Port connection is

online.

Т8 Commentary: fabric has successfully merged. Two switch entries exist.

Т8 Commentary: There is synchronization on Port 4/46 and Port 4/47 after DUT reset. E_Port

connection is online.

Page 23: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 23

Т8 Commentary: fabric has successfully merged. Two switch entries exist.

Results: All of the following criteria PASS.

Page 24: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 24

5.7.1.7 Extended Duration I/O Test (12 h)

Objective: Verify the ability of the DUT to pass fibre channel traffic over an extended time period.

Configuration:

1. Configure per diagram as shown in configuration 6.

2. Clear port statistics counters on the switches prior to testing, e.g. statsclear,

3. Configure Iometer on host to execute sequential writes using a large block size

(e.g., 512k).

Test Steps:

1. Let the I/O run for 12 hours.

2. Record the output for each E_Port interface, e.g. portStatsShow.

Т8 Commentary: Port statistic for first switch (before 12hour test).

Т8 Commentary: Port performance for first switch.

Page 25: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 25

Т8 Commentary: Port statistic for second switch (before 12hour test).

Page 26: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 26

Т8 Commentary: Port performance for second switch (before 12hour test).

Т8 Commentary: Port 4/46. There are no errors or alarm after 12hour test.

Page 27: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 27

Т8 Commentary: Port 4/47. There are no errors or alarm after 12hour test.

Page 28: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 28

Т8 Commentary: Port 4/46. There are no errors or alarm after 12hour test.

Т8 Commentary: Port 4/47. There are no errors or alarm after 16hour test.

Page 29: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 29

Т8 Commentary: Port performance for first switch (before 12hour test).

Т8 Commentary: Port performance for second switch (before 12hour test).

Results All of the following criteria PASS.

Page 30: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 30

5.7.1.8 ISL Trunking Test Objective: Verify the ability of the DUT to support Brocade ISL Trunking.

Configuration: Configure per diagram as shown in configuration 6. Add one or more E ports from Brocade switch

to the DUT

Test Steps: 1. Enable the switch ports Trunking and QoS using the command Portcfgtrunkport, portcfgqos.

2. Verify that the trunking is formed among all the ports that connected to the DUT using the commands, e.g.

switchShow, trunkShow, islshow.

Т8 Commentary: ISL trunking test passed. Ports can trunk.

Expected Results: All of the following criteria must be met for this test case to PASS.

Other:

No abnormal errors in the Host, Storage, Switch or DUT logs.

Notes: Repeat on each switch model that compatibility is required for.

Page 31: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 31

5.7.1.10 16G ISL D port

Objective: Verify the ability of the DUT to support Brocade 16G D port test.

Configuration: Configure per diagram as shown in configuration 6.

Test Steps:

1. Enable the D port mode on the port that is connected to the DUT using the command portcfgdport.

Т8 Commentary: D port mode enable to Port 4/46 on first switch.

Т8 Commentary: D port mode enable to Port 4/46 on second switch.

2. Verify the test results using the command Portdporttest.

Т8 Commentary: Electrical loopback test and link traffic test passed.

Page 32: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 32

Т8 Commentary: Electrical loopback test and link traffic test passed.

Expected Results: All of the following criteria must be met for this test case to PASS. Record the results.

Notes: Repeat on each switch model that compatibility is required for.

Page 33: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 33

5.7.1.11 16G ISL Compression Objective: Verify the ability of the DUT to support Brocade 16G ISL compression.

Configuration: Configure per diagram as shown in configuration 6.

Test Steps:

1. Enable the E port compression on the port that is connected to the DUT using the command

portcfgcompress.

Т8 Commentary: E port compression enable to Port 4/46 on first switch. E port compression is

active.

Т8 Commentary: E port compression enable to Port 4/46 on second switch. E port compression is

active.

2. Verify that the E_port is up using the command, e.g. switchShow, portcfgshow, PorEncCompShow.

Page 34: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 34

Page 35: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 35

Expected Results: All of the following criteria must be met for this test case to PASS.

Other: No abnormal errors in the Host, Storage, Switch or DUT logs.

Notes: Repeat on each switch model that compatibility is required for.

Page 36: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 36

5.7.1.12 16G ISL encryption Objective: Verify the ability of the DUT to support Brocade 16G ISL Encryption

Configuration: Configure per diagram as shown in configuration 6.

Test Steps:

1. Enable the E port compression on the port that is connected to the DUT using the command

portcfgEncrypt, AuthUtil,SecAuthSecret.

Page 37: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 37

Page 38: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 38

2. Verify that the E_port is up using the command, e.g. switchShow, portcfgshow, PorEncCompShow

Т8 Commentary: E_Port connection via port 4/46 is online.

Т8 Commentary: E_Port connection via port 4/46 is online.

Expected Results: All of the following criteria must be met for this test case to PASS.

Other: No abnormal errors in the Host, Storage, Switch or DUT logs.

Notes: Repeat on each switch model that compatibility is required for.

Page 39: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 39

5.7.1 SAN Extension Tests. R_RDY MODE.

The test configuration consists of two switches interconnected by the DUT and separated by a

long haul MAN/WAN network.

There is no Host and Target in this test. Flow generator function is used for traffic emulation.

Ports #0-#8 Brocade SW 6510 connect to port Client #1-#9 MS-100E-T10 card. Ports Line 1

both MS-100E-T10 cards connect between themselves.

Brocade 6510#1

MS-100EDUT #1

Port Client #1- #9 MS-100E

DUT #2

Port Line Port LinePort0-8

Brocade 6510#1

Port Client #1 - #9

Port0-8

Flow generator was used for traffic emulation.

Page 40: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 40

SW 6510 FOS version:

Page 41: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 41

5.7.1.1 E-Port Disable/Enable Test

Objective: To verify that the fabric can form correctly over the long distance link when the link

port is disabled and enabled.

Configuration: 1. Configure per diagram as shown in configuration 6.

Test Steps:

Т8 Commentary: R_RDY Mode was activate. Fabric has successfully merged. Two switch

entries exist.

Page 42: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 42

Page 43: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 43

1. Execute a command to disable, e.g. portDisable <port#>, an E_Port connecting the two

switches.

2. Fabric reconfiguration should result and the switches should be segmented.

3. Verify that the E_Port connection is offline from switch info., e.g. switchShow , on both

switches.

4. Verify that two individual fabrics exist, each containing a single switch, e.g. fabricShow , on

both switches.

Т8 Commentary: Port 0 is disable. E_Port connection is offline. Two individual fabrics

exist, each containing a single switch.

Page 44: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 44

5. Merge the switches by re-enable the E-port, e.g. portEnable <port#>.

6. Verify E_Port is online on both switches, e.g. switchShow.

7. Verify the fabric has successfully merged, e.g. fabricShow on each switch. Two switch entries

should exist.

Page 45: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 45

Page 46: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 46

Т8 Commentary: Port 0 6510 #1 is enable. E_Port connection is online. Fabric has

successfully merged. Two switch entries exist.

Results:

All of the following criteria PASS.

Page 47: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 47

5.7.1.2 E-Port Cable Disconnect/Reconnect Test

Objective: To verify that the fabric can form correctly over the long distance link when the link

port is disconnected then reconnected.

Configuration: 1. Configure per diagram as shown in configuration 6.

Test Steps:

1. Disconnect the FC cable from one switch.

2. Fabric reconfiguration should result and the switches should be segmented.

3. Verify that the E_Port connection is offline from switch info., e.g. switchShow on both

switches

4. Verify that two individual fabrics exist, each containing a single switch, e.g. fabricShow on

both switches.

Page 48: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 48

Т8 Commentary: There is no power on Port 0 cable’s disconnection. There is no

synchronization on Port 0 cable’s disconnection. E_Port connection is offline. Two

individual fabrics exist, each containing a single switch.

5. Merge the switches by re-connecting the cable.

6. Verify the E_Port is online on both switches, e.g. switchShow.

7. Verify the fabric has successfully merged, e.g. fabricShow on each switch. Two switch entries

should exist.

Т8 Commentary: There is synchronization on Port 0 cable’s connection. E_Port connection

is online. fabric has successfully merged. Two switch entries exist.

Page 49: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 49

Page 50: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 50

Results: All of the following criteria PASS.

Page 51: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 51

5.7.1.3 Long Haul Network Failure (No Redundancy)

Objective: To verify that the fabric can form correctly over the long distance link after a

network failure.

Configuration: 1. Configure per diagram as shown in configuration 6.

Brocade 6510#1

MS-100EDUT #1

Port Client #1- #9 MS-100E

DUT #2

Port Line Port LinePort0-8

Brocade 6510#1

Port Client #1 - #9

Port0-8

Test Steps:

7. Disable the long haul network via cable disconnect.

Т8 Commentary: Disable the long haul network via MS-100E-T10 card Port Line cable

disconnect.

8. Verify that the E_Port connection is offline, e.g. switchShow, on both switches.

9. Verify that two individual fabrics exist, each containing a single switch, e.g. fabricShow on

both switches.

Т8 Commentary: There is no sync on Port 0 after line cable’s disconnection. E_Port

connection is offline. Two individual fabrics exist, each containing a single switch.

Page 52: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 52

10. Merge the switches by re-enabling the long haul port.

Т8 Commentary: Enable the long haul network via TD-10E card Port Line #1 cable

connect.

Brocade 6510#1

MS-100EDUT #1

Port Client #1- #9 MS-100E

DUT #2

Port Line Port LinePort0-8

Brocade 6510#1

Port Client #1 - #9

Port0-8

11. Execute switchShow and verify the E_Port is online on both switches.

12. Verify the fabric has successfully merged, e.g. fabricShow on each switch. Two switch

entries should exist.

Т8 Commentary: There is sync on Port 0 and after cable connection. E_Port connection is

online. Fabric has successfully merged. Two switch entries exist.

Page 53: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 53

Page 54: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 54

Results:

All of the following criteria PASS.

Page 55: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 55

5.7.1.5 Switch Reboot Test

Objective: To verify that the fabric can form correctly over the long distance link when a switch

is reset.

ConfigurationConfigure per diagram as shown in configuration 6.

Test Steps:

4. Reboot one switch, e.g. fastboot.

5. Verify that the E_Port connection is offline on the remote switch, e.g. switchShow.

Т8 Commentary: Two individual fabrics exist, each containing a single switch. Port 0 6510

#1 are out of sync. E_Port connection is offline.

6. After the rebooted switch is again online, verify that the E_Port performs link

initialization and the fabric merges, e.g. switchShow and fabricShow, on both switches.

Page 56: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 56

Т8 Commentary: fabric has successfully merged. Two switch entries exist. Port 0 6510 #1

are in sync. E_Port connection is online.

Results: All of the following criteria PASS.

Page 57: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 57

5.7.1.6 DUT Reset Test

Objective: To verify that the fabric can form correctly over the long distance link when the

DUT is reset.

Configuration: 1. Configure per diagram as shown in configuration 6.

Test Steps:

1. Reboot one of the DUT devices via power cycle or management interface.

2. Verify that the E_Port connection is offline on the remote switch, e.g. switchShow.

Т8 Commentary: There is no power on Port 0 during DUT reset. E_Port connection is

offline. Two individual fabrics exist, each containing a single switch.

3.After the rebooted switch is again online, verify that the E_Port performs link initialization and

the fabric merges, e.g. switchShow and fabricShow, on both switches.

Page 58: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 58

Page 59: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 59

Т8 Commentary: There is power on Port 0 after DUT reset. E_Port connection is online.

Fabric has successfully merged. Two switch entries exist. Results: All of the following criteria PASS.

Page 60: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 60

Additional tests

Test for trunked configuration

Port 0,1,2,3,4,5,6,7 are trunked8x8G=64G

Port 10,11,12,13 are SIM-port4x16G=64G

SW 6510 #1B153-6510

SW 6510 #1B154-6510

Port 10,11,12,13 are SIM-port4x16G=64GMS-100E

DUT #1

Port Client #1Client #2Client #3Client #4Client #5Client #6Client #7Client #8 Port Line

MS-100EDUT #2

Port Line

Port 0,1,2,3,4,5,6,7 are trunked8x8G=64G

Port Client #1Client #2Client #3Client #4Client #5Client #6Client #7Client #8

Port 8 -redundant link 8G

Port 8 -redundant link 8G

Port 0-7 are trunked. Port 8 is a redundant link.

Page 61: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 61

a. Disable all of the slaves first, then the master. Enable the last known master

first, verify it comes online, then enable the other slaves and verify they join

the trunk.

Disable all of the slaves.

Page 62: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 62

Disable master.

Page 63: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 63

Enable the last known master first.

Then enable the other slaves and verify they join the trunk

Page 64: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 64

Т8 Commentary: All ports join the trunk.

Page 65: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 65

b. Disable all of the slaves first, then the master. Then enable one of the slave

ports first, verify it comes online, then enable the other ports in any order

and verify they join the trunk.

Disable all of the slaves first (ports 1-7), then the master (port 0).

Then enable one of the slave ports first (port 7).

Page 66: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 66

Then enable the other ports.

Т8 Commentary: All ports join the trunk.

c. Disable the master port first. Keep disabling all of the ports in a trunk,

targeting the newly selected master port, until all ports in that trunk are

disabled. Then enable the last disabled port first and verify it comes online,

then enable the other ports in any order and verify they join the trunk.

B153-6510:admin> trunkshow -perf

1: 5-> 5 10:00:00:05:33:9f:66:02 1 deskew 44 MASTER

1-> 1 10:00:00:05:33:9f:66:02 1 deskew 19

2-> 2 10:00:00:05:33:9f:66:02 1 deskew 21

0-> 0 10:00:00:05:33:9f:66:02 1 deskew 15

3-> 3 10:00:00:05:33:9f:66:02 1 deskew 23

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 28

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 18

7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15

Tx: Bandwidth 64.00Gbps, Throughput 48.83Gbps (88.81%)

Rx: Bandwidth 64.00Gbps, Throughput 40.11Gbps (72.95%)

Tx+Rx: Bandwidth 128.00Gbps, Throughput 88.93Gbps (80.88%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 4.81Gbps (70.05%)

Page 67: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 67

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.28%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 11.50Gbps (83.66%)

B153-6510:admin> portdisable 5

B153-6510:admin> trunkshow -perf

1: 0-> 0 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15

1-> 1 10:00:00:05:33:9f:66:02 1 deskew 19

2-> 2 10:00:00:05:33:9f:66:02 1 deskew 21

3-> 3 10:00:00:05:33:9f:66:02 1 deskew 23

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 28

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 18

Tx: Bandwidth 56.00Gbps, Throughput 46.75Gbps (97.19%)

Rx: Bandwidth 56.00Gbps, Throughput 40.12Gbps (83.41%)

Tx+Rx: Bandwidth 112.00Gbps, Throughput 86.87Gbps (90.30%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

B153-6510:admin> portdisable 0

B153-6510:admin> trunkshow -perf

1: 1-> 1 10:00:00:05:33:9f:66:02 1 deskew 19 MASTER

7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15

2-> 2 10:00:00:05:33:9f:66:02 1 deskew 21

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 18

3-> 3 10:00:00:05:33:9f:66:02 1 deskew 23

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 28

Tx: Bandwidth 48.00Gbps, Throughput 40.07Gbps (97.19%)

Rx: Bandwidth 48.00Gbps, Throughput 40.07Gbps (97.19%)

Tx+Rx: Bandwidth 96.00Gbps, Throughput 80.14Gbps (97.19%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

B153-6510:admin> portdisable 1

B153-6510:admin> trunkshow -perf

1: 2-> 2 10:00:00:05:33:9f:66:02 1 deskew 21 MASTER

7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 28

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 18

3-> 3 10:00:00:05:33:9f:66:02 1 deskew 23

Tx: Bandwidth 40.00Gbps, Throughput 33.39Gbps (97.19%)

Rx: Bandwidth 40.00Gbps, Throughput 33.39Gbps (97.19%)

Tx+Rx: Bandwidth 80.00Gbps, Throughput 66.79Gbps (97.19%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Page 68: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 68

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

B153-6510:admin> portdisable 2

B153-6510:admin> trunkshow -perf

1: 3-> 3 10:00:00:05:33:9f:66:02 1 deskew 23 MASTER

7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 28

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 18

Tx: Bandwidth 32.00Gbps, Throughput 26.71Gbps (97.19%)

Rx: Bandwidth 32.00Gbps, Throughput 26.71Gbps (97.19%)

Tx+Rx: Bandwidth 64.00Gbps, Throughput 53.43Gbps (97.19%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

B153-6510:admin> portdisable 3

B153-6510:admin> trunkshow -perf

1: 4-> 4 10:00:00:05:33:9f:66:02 1 deskew 28 MASTER

7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 18

Tx: Bandwidth 24.00Gbps, Throughput 20.04Gbps (97.18%)

Rx: Bandwidth 24.00Gbps, Throughput 20.04Gbps (97.18%)

Tx+Rx: Bandwidth 48.00Gbps, Throughput 40.07Gbps (97.18%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.18%)

B153-6510:admin> portdisable 4

B153-6510:admin> trunkshow -perf

1: 6-> 6 10:00:00:05:33:9f:66:02 1 deskew 18 MASTER

7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15

Tx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

Tx+Rx: Bandwidth 32.00Gbps, Throughput 26.71Gbps (97.19%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

B153-6510:admin> portdisable 6

B153-6510:admin> trunkshow -perf

1: 7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

Page 69: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 69

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

B153-6510:admin> portdisable 7

B153-6510:admin> trunkshow -perf

1: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.18%)

B153-6510:admin> portenable 7

B153-6510:admin> trunkshow -perf

1: 7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.18%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.18%)

B153-6510:admin> portenable 6

B153-6510:admin> trunkshow -perf

1: 7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.18%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.18%)

B153-6510:admin> portenable 5

B153-6510:admin> trunkshow -perf

1: 7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 15

5-> 5 10:00:00:05:33:9f:66:02 1 deskew 25

Tx: Bandwidth 24.00Gbps, Throughput 20.04Gbps (97.19%)

Rx: Bandwidth 24.00Gbps, Throughput 20.04Gbps (97.19%)

Tx+Rx: Bandwidth 48.00Gbps, Throughput 40.07Gbps (97.19%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

Page 70: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 70

B153-6510:admin> portenable 4

B153-6510:admin> trunkshow -perf

1: 7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 16

5-> 5 10:00:00:05:33:9f:66:02 1 deskew 25

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 21

Tx: Bandwidth 32.00Gbps, Throughput 25.97Gbps (94.50%)

Rx: Bandwidth 32.00Gbps, Throughput 25.97Gbps (94.49%)

Tx+Rx: Bandwidth 64.00Gbps, Throughput 51.95Gbps (94.49%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.67Gbps (97.09%)

Rx: Bandwidth 8.00Gbps, Throughput 6.67Gbps (97.08%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.34Gbps (97.09%)

B153-6510:admin> portenable 3

B153-6510:admin> trunkshow -perf

1: 7-> 7 10:00:00:05:33:9f:66:02 1 deskew 17 MASTER

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 18

5-> 5 10:00:00:05:33:9f:66:02 1 deskew 27

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 22

3-> 3 10:00:00:05:33:9f:66:02 1 deskew 15

Tx: Bandwidth 40.00Gbps, Throughput 33.39Gbps (97.19%)

Rx: Bandwidth 40.00Gbps, Throughput 33.39Gbps (97.19%)

Tx+Rx: Bandwidth 80.00Gbps, Throughput 66.79Gbps (97.19%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

B153-6510:admin> portenable 2

B153-6510:admin> trunkshow -perf

1: 7-> 7 10:00:00:05:33:9f:66:02 1 deskew 17 MASTER

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 17

5-> 5 10:00:00:05:33:9f:66:02 1 deskew 26

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 22

3-> 3 10:00:00:05:33:9f:66:02 1 deskew 15

2-> 2 10:00:00:05:33:9f:66:02 1 deskew 24

Tx: Bandwidth 48.00Gbps, Throughput 40.09Gbps (97.22%)

Rx: Bandwidth 48.00Gbps, Throughput 38.23Gbps (92.72%)

Tx+Rx: Bandwidth 96.00Gbps, Throughput 78.32Gbps (94.97%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

B153-6510:admin> portenable 1

B153-6510:admin> trunkshow -perf

1: 7-> 7 10:00:00:05:33:9f:66:02 1 deskew 18 MASTER

Page 71: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 71

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 18

5-> 5 10:00:00:05:33:9f:66:02 1 deskew 27

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 23

3-> 3 10:00:00:05:33:9f:66:02 1 deskew 15

2-> 2 10:00:00:05:33:9f:66:02 1 deskew 25

1-> 1 10:00:00:05:33:9f:66:02 1 deskew 24

Tx: Bandwidth 56.00Gbps, Throughput 46.76Gbps (97.20%)

Rx: Bandwidth 56.00Gbps, Throughput 40.09Gbps (83.33%)

Tx+Rx: Bandwidth 112.00Gbps, Throughput 86.84Gbps (90.27%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

B153-6510:admin> portenable 0

B153-6510:admin> trunkshow -perf

1: 7-> 7 10:00:00:05:33:9f:66:02 1 deskew 23 MASTER

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 23

5-> 5 10:00:00:05:33:9f:66:02 1 deskew 32

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 27

3-> 3 10:00:00:05:33:9f:66:02 1 deskew 20

2-> 2 10:00:00:05:33:9f:66:02 1 deskew 30

1-> 1 10:00:00:05:33:9f:66:02 1 deskew 28

0-> 0 10:00:00:05:33:9f:66:02 1 deskew 15

Tx: Bandwidth 64.00Gbps, Throughput 48.82Gbps (88.81%)

Rx: Bandwidth 64.00Gbps, Throughput 42.39Gbps (77.11%)

Tx+Rx: Bandwidth 128.00Gbps, Throughput 91.21Gbps (82.96%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 4.81Gbps (70.05%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.28%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 11.50Gbps (83.66%)

Т8 Commentary: All ports join the trunk.

Page 72: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 72

d. Disable the master port first. Keep disabling all of the ports in a trunk,

targeting the newly selected master port, until all ports in that trunk are

disabled. Then enable any single port within the trunk except for the last

disabled port. Verify it comes online, then enable the other ports in any

order and verify they join the trunk.

B153-6510:admin> trunkshow -perf

1: 7-> 7 10:00:00:05:33:9f:66:02 1 deskew 23 MASTER

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 23

5-> 5 10:00:00:05:33:9f:66:02 1 deskew 32

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 27

3-> 3 10:00:00:05:33:9f:66:02 1 deskew 20

2-> 2 10:00:00:05:33:9f:66:02 1 deskew 30

1-> 1 10:00:00:05:33:9f:66:02 1 deskew 28

0-> 0 10:00:00:05:33:9f:66:02 1 deskew 15

Tx: Bandwidth 64.00Gbps, Throughput 48.82Gbps (88.81%)

Rx: Bandwidth 64.00Gbps, Throughput 42.39Gbps (77.11%)

Tx+Rx: Bandwidth 128.00Gbps, Throughput 91.21Gbps (82.96%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 4.81Gbps (70.05%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.28%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 11.50Gbps (83.66%)

B153-6510:admin> portdisable 7

B153-6510:admin> trunkshow -perf

1: 0-> 0 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 23

5-> 5 10:00:00:05:33:9f:66:02 1 deskew 32

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 27

3-> 3 10:00:00:05:33:9f:66:02 1 deskew 20

2-> 2 10:00:00:05:33:9f:66:02 1 deskew 30

1-> 1 10:00:00:05:33:9f:66:02 1 deskew 28

Tx: Bandwidth 56.00Gbps, Throughput 46.79Gbps (97.28%)

Rx: Bandwidth 56.00Gbps, Throughput 40.72Gbps (84.65%)

Tx+Rx: Bandwidth 112.00Gbps, Throughput 87.51Gbps (90.96%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.18%)

B153-6510:admin> portdisable 0

B153-6510:admin> trunkshow -perf

1: 1-> 1 10:00:00:05:33:9f:66:02 1 deskew 23 MASTER

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 18

5-> 5 10:00:00:05:33:9f:66:02 1 deskew 27

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 22

3-> 3 10:00:00:05:33:9f:66:02 1 deskew 15

2-> 2 10:00:00:05:33:9f:66:02 1 deskew 25

Tx: Bandwidth 48.00Gbps, Throughput 40.10Gbps (97.25%)

Page 73: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 73

Rx: Bandwidth 48.00Gbps, Throughput 38.93Gbps (94.41%)

Tx+Rx: Bandwidth 96.00Gbps, Throughput 79.03Gbps (95.83%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.18%)

B153-6510:admin> portdisable 1

B153-6510:admin> trunkshow -perf

1: 2-> 2 10:00:00:05:33:9f:66:02 1 deskew 25 MASTER

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 18

5-> 5 10:00:00:05:33:9f:66:02 1 deskew 27

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 22

3-> 3 10:00:00:05:33:9f:66:02 1 deskew 15

Tx: Bandwidth 40.00Gbps, Throughput 33.41Gbps (97.23%)

Rx: Bandwidth 40.00Gbps, Throughput 33.41Gbps (97.24%)

Tx+Rx: Bandwidth 80.00Gbps, Throughput 66.82Gbps (97.24%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

B153-6510:admin> portdisable 2

B153-6510:admin> trunkshow -perf

1: 3-> 3 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 18

5-> 5 10:00:00:05:33:9f:66:02 1 deskew 27

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 22

Tx: Bandwidth 32.00Gbps, Throughput 26.73Gbps (97.23%)

Rx: Bandwidth 32.00Gbps, Throughput 26.73Gbps (97.23%)

Tx+Rx: Bandwidth 64.00Gbps, Throughput 53.45Gbps (97.23%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.18%)

B153-6510:admin> portdisable 3

B153-6510:admin> trunkshow -perf

1: 4-> 4 10:00:00:05:33:9f:66:02 1 deskew 19 MASTER

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 15

5-> 5 10:00:00:05:33:9f:66:02 1 deskew 24

Tx: Bandwidth 24.00Gbps, Throughput 20.04Gbps (97.23%)

Rx: Bandwidth 24.00Gbps, Throughput 20.05Gbps (97.23%)

Tx+Rx: Bandwidth 48.00Gbps, Throughput 40.09Gbps (97.23%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Page 74: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 74

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.18%)

B153-6510:admin> portdisable 4

B153-6510:admin> trunkshow -perf

1: 5-> 5 10:00:00:05:33:9f:66:02 1 deskew 24 MASTER

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 15

Tx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.23%)

Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.23%)

Tx+Rx: Bandwidth 32.00Gbps, Throughput 26.73Gbps (97.23%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.18%)

B153-6510:admin> portdisable 5

B153-6510:admin> trunkshow -perf

1: 6-> 6 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.23%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.23%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.23%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.18%)

B153-6510:admin> portdisable 6

B153-6510:admin> trunkshow -perf

1: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

B153-6510:admin> portenable 5

B153-6510:admin> trunkshow -perf

1: 5-> 5 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.23%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.23%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.23%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.18%)

B153-6510:admin> portenable 7

B153-6510:admin> trunkshow -perf

1: 5-> 5 10:00:00:05:33:9f:66:02 1 deskew 45 MASTER

7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15

Tx: Bandwidth 16.00Gbps, Throughput 12.64Gbps (91.94%)

Page 75: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 75

Rx: Bandwidth 16.00Gbps, Throughput 12.64Gbps (91.96%)

Tx+Rx: Bandwidth 32.00Gbps, Throughput 25.28Gbps (91.95%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.67Gbps (97.08%)

Rx: Bandwidth 8.00Gbps, Throughput 6.67Gbps (97.11%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.34Gbps (97.09%)

B153-6510:admin> portenable 4

B153-6510:admin> trunkshow -perf

1: 5-> 5 10:00:00:05:33:9f:66:02 1 deskew 45 MASTER

7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 42

Tx: Bandwidth 24.00Gbps, Throughput 13.34Gbps (64.73%)

Rx: Bandwidth 24.00Gbps, Throughput 13.34Gbps (64.73%)

Tx+Rx: Bandwidth 48.00Gbps, Throughput 26.69Gbps (64.73%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.67Gbps (97.11%)

Rx: Bandwidth 8.00Gbps, Throughput 6.67Gbps (97.11%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.35Gbps (97.11%)

^[[AB153-6510:admin> portenable 3

B153-6510:admin> trunkshow -perf

1: 5-> 5 10:00:00:05:33:9f:66:02 1 deskew 45 MASTER

7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 42

3-> 3 10:00:00:05:33:9f:66:02 1 deskew 24

Tx: Bandwidth 32.00Gbps, Throughput 26.71Gbps (97.19%)

Rx: Bandwidth 32.00Gbps, Throughput 26.71Gbps (97.19%)

Tx+Rx: Bandwidth 64.00Gbps, Throughput 53.43Gbps (97.19%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.18%)

B153-6510:admin> portenable 2

B153-6510:admin> trunkshow -perf

1: 5-> 5 10:00:00:05:33:9f:66:02 1 deskew 45 MASTER

7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 42

3-> 3 10:00:00:05:33:9f:66:02 1 deskew 24

2-> 2 10:00:00:05:33:9f:66:02 1 deskew 33

Tx: Bandwidth 40.00Gbps, Throughput 33.39Gbps (97.19%)

Rx: Bandwidth 40.00Gbps, Throughput 33.39Gbps (97.19%)

Tx+Rx: Bandwidth 80.00Gbps, Throughput 66.79Gbps (97.19%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Page 76: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 76

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

B153-6510:admin> portenable 1

B153-6510:admin> trunkshow -perf

1: 5-> 5 10:00:00:05:33:9f:66:02 1 deskew 45 MASTER

7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 42

3-> 3 10:00:00:05:33:9f:66:02 1 deskew 24

2-> 2 10:00:00:05:33:9f:66:02 1 deskew 33

1-> 1 10:00:00:05:33:9f:66:02 1 deskew 36

Tx: Bandwidth 48.00Gbps, Throughput 40.09Gbps (97.22%)

Rx: Bandwidth 48.00Gbps, Throughput 38.37Gbps (93.06%)

Tx+Rx: Bandwidth 96.00Gbps, Throughput 78.45Gbps (95.14%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

B153-6510:admin> portenable 0

B153-6510:admin> trunkshow -perf

1: 5-> 5 10:00:00:05:33:9f:66:02 1 deskew 45 MASTER

7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 42

3-> 3 10:00:00:05:33:9f:66:02 1 deskew 23

2-> 2 10:00:00:05:33:9f:66:02 1 deskew 33

1-> 1 10:00:00:05:33:9f:66:02 1 deskew 35

0-> 0 10:00:00:05:33:9f:66:02 1 deskew 30

Tx: Bandwidth 56.00Gbps, Throughput 43.89Gbps (91.24%)

Rx: Bandwidth 56.00Gbps, Throughput 40.11Gbps (83.38%)

Tx+Rx: Bandwidth 112.00Gbps, Throughput 84.00Gbps (87.31%)

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.19%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.19%)

B153-6510:admin> portenable 6

B153-6510:admin> trunkshow -perf

1: 5-> 5 10:00:00:05:33:9f:66:02 1 deskew 45 MASTER

7-> 7 10:00:00:05:33:9f:66:02 1 deskew 15

4-> 4 10:00:00:05:33:9f:66:02 1 deskew 42

3-> 3 10:00:00:05:33:9f:66:02 1 deskew 23

2-> 2 10:00:00:05:33:9f:66:02 1 deskew 33

1-> 1 10:00:00:05:33:9f:66:02 1 deskew 35

0-> 0 10:00:00:05:33:9f:66:02 1 deskew 30

6-> 6 10:00:00:05:33:9f:66:02 1 deskew 26

Tx: Bandwidth 64.00Gbps, Throughput 40.14Gbps (73.01%)

Rx: Bandwidth 64.00Gbps, Throughput 33.46Gbps (60.86%)

Tx+Rx: Bandwidth 128.00Gbps, Throughput 73.60Gbps (66.94%)

Page 77: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 77

2: 8-> 8 10:00:00:05:33:9f:66:02 1 deskew 15 MASTER

Tx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Rx: Bandwidth 8.00Gbps, Throughput 6.68Gbps (97.18%)

Tx+Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.18%)

Т8 Commentary: All ports join the trunk.

Hareboot test

Т8 Commentary: E_Port connection is online. Fabric has successfully merged. Two switch

entries exist.

Page 78: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 78

B153-6510:admin> portstatsshow 0

stat_wtx 3025334596 4-byte words transmitted

stat_wrx 3027515049 4-byte words received

stat_ftx 178924503 Frames transmitted

stat_frx 178928685 Frames received

stat_c2_frx 0 Class 2 frames received

stat_c3_frx 178928663 Class 3 frames received

stat_lc_rx 18 Link control frames received

stat_mc_rx 0 Multicast frames received

stat_mc_to 0 Multicast timeouts

stat_mc_tx 0 Multicast frames transmitted

tim_rdy_pri 2888862 Time R_RDY high priority

tim_txcrd_z 0 Time TX Credit Zero (2.5Us ticks)

tim_txcrd_z_vc 0- 3: 0 0 0 0

tim_txcrd_z_vc 4- 7: 0 0 0 0

tim_txcrd_z_vc 8-11: 0 0 0 0

tim_txcrd_z_vc 12-15: 0 0 0 0

er_enc_in 0 Encoding errors inside of frames

er_crc 0 Frames with CRC errors

er_trunc 0 Frames shorter than minimum

er_toolong 0 Frames longer than maximum

er_bad_eof 0 Frames with bad end-of-frame

er_enc_out 0 Encoding error outside of frames

er_bad_os 0 Invalid ordered set

er_pcs_blk 0 PCS block errors

er_rx_c3_timeout 0 Class 3 receive frames discarded due to timeout

er_tx_c3_timeout 0 Class 3 transmit frames discarded due to timeout

er_unroutable 0 Frames that are unroutable

er_unreachable 0 Frames with unreachable destination

Page 79: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 79

er_other_discard 0 Other discards

er_type1_miss 0 frames with FTB type 1 miss

er_type2_miss 0 frames with FTB type 2 miss

er_type6_miss 0 frames with FTB type 6 miss

er_zone_miss 0 frames with hard zoning miss

er_lun_zone_miss 0 frames with LUN zoning miss

er_crc_good_eof 0 Crc error with good eof

er_inv_arb 0 Invalid ARB

er_single_credit_loss 0 Single vcrdy/frame loss on link

er_multi_credit_loss 0 Multiple vcrdy/frame loss on link

phy_stats_clear_ts 09-05-2016 Localtime Mon 14:42:26 Timestamp of phy_port stats

clear

lgc_stats_clear_ts 09-05-2016 Localtime Mon 14:42:26 Timestamp of lgc_port stats clear

B153-6510:admin> portstatsshow 1

stat_wtx 3769768348 4-byte words transmitted

stat_wrx 3771966408 4-byte words received

stat_ftx 180353357 Frames transmitted

stat_frx 180357569 Frames received

stat_c2_frx 0 Class 2 frames received

stat_c3_frx 180357552 Class 3 frames received

stat_lc_rx 11 Link control frames received

stat_mc_rx 0 Multicast frames received

stat_mc_to 0 Multicast timeouts

stat_mc_tx 0 Multicast frames transmitted

tim_rdy_pri 2367835 Time R_RDY high priority

tim_txcrd_z 0 Time TX Credit Zero (2.5Us ticks)

tim_txcrd_z_vc 0- 3: 0 0 0 0

tim_txcrd_z_vc 4- 7: 0 0 0 0

tim_txcrd_z_vc 8-11: 0 0 0 0

tim_txcrd_z_vc 12-15: 0 0 0 0

er_enc_in 0 Encoding errors inside of frames

er_crc 0 Frames with CRC errors

er_trunc 0 Frames shorter than minimum

er_toolong 0 Frames longer than maximum

er_bad_eof 0 Frames with bad end-of-frame

er_enc_out 0 Encoding error outside of frames

er_bad_os 0 Invalid ordered set

er_pcs_blk 0 PCS block errors

er_rx_c3_timeout 0 Class 3 receive frames discarded due to timeout

er_tx_c3_timeout 0 Class 3 transmit frames discarded due to timeout

er_unroutable 0 Frames that are unroutable

er_unreachable 0 Frames with unreachable destination

er_other_discard 0 Other discards

er_type1_miss 0 frames with FTB type 1 miss

er_type2_miss 0 frames with FTB type 2 miss

er_type6_miss 0 frames with FTB type 6 miss

er_zone_miss 0 frames with hard zoning miss

er_lun_zone_miss 0 frames with LUN zoning miss

er_crc_good_eof 0 Crc error with good eof

er_inv_arb 0 Invalid ARB

er_single_credit_loss 0 Single vcrdy/frame loss on link

Page 80: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 80

er_multi_credit_loss 0 Multiple vcrdy/frame loss on link

phy_stats_clear_ts 09-05-2016 Localtime Mon 14:42:26 Timestamp of phy_port stats

clear

lgc_stats_clear_ts 09-05-2016 Localtime Mon 14:42:26 Timestamp of lgc_port stats clear

B154-6510:admin> portstatsshow 0

stat_wtx 1237406455 4-byte words transmitted

stat_wrx 1235074034 4-byte words received

stat_ftx 191980183 Frames transmitted

stat_frx 191975699 Frames received

stat_c2_frx 0 Class 2 frames received

stat_c3_frx 191975675 Class 3 frames received

stat_lc_rx 12 Link control frames received

stat_mc_rx 0 Multicast frames received

stat_mc_to 0 Multicast timeouts

stat_mc_tx 0 Multicast frames transmitted

tim_rdy_pri 2574997 Time R_RDY high priority

tim_txcrd_z 0 Time TX Credit Zero (2.5Us ticks)

tim_txcrd_z_vc 0- 3: 0 0 0 0

tim_txcrd_z_vc 4- 7: 0 0 0 0

tim_txcrd_z_vc 8-11: 0 0 0 0

tim_txcrd_z_vc 12-15: 0 0 0 0

tim_latency_vc 0- 3: 1 1 217 1

tim_latency_vc 4- 7: 1 1 1 1

tim_latency_vc 8-11: 1 1 1 1

tim_latency_vc 12-15: 1 1 1 1

er_enc_in 0 Encoding errors inside of frames

er_crc 0 Frames with CRC errors

er_trunc 0 Frames shorter than minimum

er_toolong 0 Frames longer than maximum

er_bad_eof 0 Frames with bad end-of-frame

er_enc_out 0 Encoding error outside of frames

er_bad_os 0 Invalid ordered set

er_pcs_blk 0 PCS block errors

er_rx_c3_timeout 0 Class 3 receive frames discarded due to timeout

er_tx_c3_timeout 0 Class 3 transmit frames discarded due to timeout

er_unroutable 0 Frames that are unroutable

er_unreachable 0 Frames with unreachable destination

er_other_discard 0 Other discards

er_type1_miss 0 frames with FTB type 1 miss

er_type2_miss 0 frames with FTB type 2 miss

er_type6_miss 0 frames with FTB type 6 miss

er_zone_miss 0 frames with hard zoning miss

er_lun_zone_miss 0 frames with LUN zoning miss

er_crc_good_eof 0 Crc error with good eof

er_inv_arb 0 Invalid ARB

er_single_credit_loss 0 Single vcrdy/frame loss on link

er_multi_credit_loss 0 Multiple vcrdy/frame loss on link

phy_stats_clear_ts 09-05-2016 Localtime Mon 14:42:31 Timestamp of phy_port stats

clear

lgc_stats_clear_ts 09-05-2016 Localtime Mon 14:42:31 Timestamp of lgc_port stats clear

Page 81: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 81

B153-6510:admin> portstatsshow 1

stat_wtx 1954431926 4-byte words transmitted

stat_wrx 1952082280 4-byte words received

stat_ftx 193356425 Frames transmitted

stat_frx 193351912 Frames received

stat_c2_frx 0 Class 2 frames received

stat_c3_frx 193351891 Class 3 frames received

stat_lc_rx 12 Link control frames received

stat_mc_rx 0 Multicast frames received

stat_mc_to 0 Multicast timeouts

stat_mc_tx 0 Multicast frames transmitted

tim_rdy_pri 2885165 Time R_RDY high priority

tim_txcrd_z 0 Time TX Credit Zero (2.5Us ticks)

tim_txcrd_z_vc 0- 3: 0 0 0 0

tim_txcrd_z_vc 4- 7: 0 0 0 0

tim_txcrd_z_vc 8-11: 0 0 0 0

tim_txcrd_z_vc 12-15: 0 0 0 0

tim_latency_vc 0- 3: 1 1 216 1

tim_latency_vc 4- 7: 1 1 1 1

tim_latency_vc 8-11: 1 1 1 1

tim_latency_vc 12-15: 1 1 1 1

er_enc_in 0 Encoding errors inside of frames

er_crc 0 Frames with CRC errors

er_trunc 0 Frames shorter than minimum

er_toolong 0 Frames longer than maximum

er_bad_eof 0 Frames with bad end-of-frame

er_enc_out 0 Encoding error outside of frames

er_bad_os 0 Invalid ordered set

er_pcs_blk 0 PCS block errors

er_rx_c3_timeout 0 Class 3 receive frames discarded due to timeout

er_tx_c3_timeout 0 Class 3 transmit frames discarded due to timeout

er_unroutable 0 Frames that are unroutable

er_unreachable 0 Frames with unreachable destination

er_other_discard 0 Other discards

er_type1_miss 0 frames with FTB type 1 miss

er_type2_miss 0 frames with FTB type 2 miss

er_type6_miss 0 frames with FTB type 6 miss

er_zone_miss 0 frames with hard zoning miss

er_lun_zone_miss 0 frames with LUN zoning miss

er_crc_good_eof 0 Crc error with good eof

er_inv_arb 0 Invalid ARB

er_single_credit_loss 0 Single vcrdy/frame loss on link

er_multi_credit_loss 0 Multiple vcrdy/frame loss on link

phy_stats_clear_ts 09-05-2016 Localtime Mon 14:42:31 Timestamp of phy_port stats

clear

lgc_stats_clear_ts 09-05-2016 Localtime Mon 14:42:31 Timestamp of lgc_port stats clear

Hareboot command on one switch:

Page 82: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 82

Fabricshow&switchshow on another switch:

Т8 Commentary: Fabric didn’t split up white hareboot. Two switch entries exist.

B154-6510:admin> trunkshow -perf

1: 1-> 1 10:00:00:05:33:91:e4:00 2 deskew 40 MASTER

0-> 0 10:00:00:05:33:91:e4:00 2 deskew 15

Tx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.24%)

Rx: Bandwidth 16.00Gbps, Throughput 13.36Gbps (97.24%)

Tx+Rx: Bandwidth 32.00Gbps, Throughput 26.73Gbps (97.24%)

B154-6510:admin> portstatsshow 0

stat_wtx 141259214 4-byte words transmitted

stat_wrx 138252302 4-byte words received

stat_ftx 247582155 Frames transmitted

stat_frx 247576374 Frames received

stat_c2_frx 0 Class 2 frames received

stat_c3_frx 247576346 Class 3 frames received

stat_lc_rx 14 Link control frames received

stat_mc_rx 0 Multicast frames received

stat_mc_to 0 Multicast timeouts

stat_mc_tx 0 Multicast frames transmitted

Page 83: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 83

tim_rdy_pri 3093371 Time R_RDY high priority

tim_txcrd_z 0 Time TX Credit Zero (2.5Us ticks)

tim_txcrd_z_vc 0- 3: 0 0 0 0

tim_txcrd_z_vc 4- 7: 0 0 0 0

tim_txcrd_z_vc 8-11: 0 0 0 0

tim_txcrd_z_vc 12-15: 0 0 0 0

tim_latency_vc 0- 3: 1 1 217 1

tim_latency_vc 4- 7: 1 1 1 1

tim_latency_vc 8-11: 1 1 1 1

tim_latency_vc 12-15: 1 1 1 1

er_enc_in 0 Encoding errors inside of frames

er_crc 0 Frames with CRC errors

er_trunc 0 Frames shorter than minimum

er_toolong 0 Frames longer than maximum

er_bad_eof 0 Frames with bad end-of-frame

er_enc_out 0 Encoding error outside of frames

er_bad_os 0 Invalid ordered set

er_pcs_blk 0 PCS block errors

er_rx_c3_timeout 0 Class 3 receive frames discarded due to timeout

er_tx_c3_timeout 0 Class 3 transmit frames discarded due to timeout

er_unroutable 0 Frames that are unroutable

er_unreachable 0 Frames with unreachable destination

er_other_discard 0 Other discards

er_type1_miss 0 frames with FTB type 1 miss

er_type2_miss 0 frames with FTB type 2 miss

er_type6_miss 0 frames with FTB type 6 miss

er_zone_miss 0 frames with hard zoning miss

er_lun_zone_miss 0 frames with LUN zoning miss

er_crc_good_eof 0 Crc error with good eof

er_inv_arb 0 Invalid ARB

er_single_credit_loss 0 Single vcrdy/frame loss on link

er_multi_credit_loss 0 Multiple vcrdy/frame loss on link

phy_stats_clear_ts 09-05-2016 Localtime Mon 14:42:31 Timestamp of phy_port stats

clear

Page 84: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 84

lgc_stats_clear_ts 09-05-2016 Localtime Mon 14:42:31 Timestamp of lgc_port stats clear

^[[AB154-6510:admin> portstatsshow 1

stat_wtx 1160920905 4-byte words transmitted

stat_wrx 1157889829 4-byte words received

stat_ftx 249539271 Frames transmitted

stat_frx 249533450 Frames received

stat_c2_frx 0 Class 2 frames received

stat_c3_frx 249533424 Class 3 frames received

stat_lc_rx 14 Link control frames received

stat_mc_rx 0 Multicast frames received

stat_mc_to 0 Multicast timeouts

stat_mc_tx 0 Multicast frames transmitted

tim_rdy_pri 3766594 Time R_RDY high priority

tim_txcrd_z 0 Time TX Credit Zero (2.5Us ticks)

tim_txcrd_z_vc 0- 3: 0 0 0 0

tim_txcrd_z_vc 4- 7: 0 0 0 0

tim_txcrd_z_vc 8-11: 0 0 0 0

tim_txcrd_z_vc 12-15: 0 0 0 0

tim_latency_vc 0- 3: 1 1 216 1

tim_latency_vc 4- 7: 1 1 1 1

tim_latency_vc 8-11: 1 1 1 1

tim_latency_vc 12-15: 1 1 1 1

er_enc_in 0 Encoding errors inside of frames

er_crc 0 Frames with CRC errors

er_trunc 0 Frames shorter than minimum

er_toolong 0 Frames longer than maximum

er_bad_eof 0 Frames with bad end-of-frame

er_enc_out 0 Encoding error outside of frames

er_bad_os 0 Invalid ordered set

er_pcs_blk 0 PCS block errors

er_rx_c3_timeout 0 Class 3 receive frames discarded due to timeout

er_tx_c3_timeout 0 Class 3 transmit frames discarded due to timeout

er_unroutable 0 Frames that are unroutable

er_unreachable 0 Frames with unreachable destination

Page 85: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 85

er_other_discard 0 Other discards

er_type1_miss 0 frames with FTB type 1 miss

er_type2_miss 0 frames with FTB type 2 miss

er_type6_miss 0 frames with FTB type 6 miss

er_zone_miss 0 frames with hard zoning miss

er_lun_zone_miss 0 frames with LUN zoning miss

er_crc_good_eof 0 Crc error with good eof

er_inv_arb 0 Invalid ARB

er_single_credit_loss 0 Single vcrdy/frame loss on link

er_multi_credit_loss 0 Multiple vcrdy/frame loss on link

phy_stats_clear_ts 09-05-2016 Localtime Mon 14:42:31 Timestamp of phy_port statsclear

lgc_stats_clear_ts 09-05-2016 Localtime Mon 14:42:31 Timestamp of lgc_port stats clear

QoS_test

Scheme for QoS:

Port 0,1,2 are trunked3x8G=24G

Port 10,11 are SIM-port2x16G=32G

SW 6510 #1B153-6510

SW 6510 #1B154-6510

Port 0,1,2 are trunked3x8G=24G

Port 10,11 are SIM-port2x16G=32G

MS-100EDUT #1

Port Client #1Client #2Client #3 Port Line

MS-100EDUT #2

Port Client #1Client #2Client #3Port Line

Switch’s configs. There is 3 trunked port

Page 86: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 86

Setting QoS zone-based traffic prioritization. One zone (QOSH1_zone) has high priority traffic, another (QOSL2_zone) has low priority traffic.

Page 87: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 87

QoS zone-based SIM-port SW 6510 #1

B153-6510

SW 6510 #2

B154-6510

QOSH1_zone Port 10/Port10 SIM-Port

20:0a:00:05:33:91:e4:00

SIM-Port

20:0a:00:05:33:9f:66:02

QOSL2_zone Port 11/Port11 SIM-Port

20:0b:00:05:33:91:e4:00

SIM-Port

20:0b:00:05:33:9f:66:02

Page 88: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 88

Flow generator and flow monitor on SIM-ports. B153-6510:admin> flow --show all

Name : flow11 Features: mon(Activated) noConfig: Off

Definition: IngrPort(10),SrcDev(0x020a00),DstDev(0x010a00)

Flow Monitor (Activated):

Monitor time: | Mon Sep 05 20:29:08 Localtime 2016 |

---------------------------------------------------------

-----------------------------------------------------------------------------------------------------

| Rx Frames Count | Rx Frames per Sec. | Rx Bytes Count | Rx Throughput(Bps) | Avg Rx Frm Sz(Bytes)|

-----------------------------------------------------------------------------------------------------

| 3.27G | 623.61k | 6.20T | 1.20G | 2084 |

-----------------------------------------------------------------------------------------------------

-------------------------------------------------------------------------------------------------

| I/O Count | I/O Per Sec.(IOPS) | I/O bytes Transferred | I/O bytes Per Sec. |

| Reads / Writes/ Total | Reads / Writes/ Total | Reads / Writes/ Total | Reads / Writes/ Total |

-------------------------------------------------------------------------------------------------

| 0 / 0 / 0 | 0 / 0 / 0 | 0 / 0 / 0 | 0 / 0 / 0 |

-------------------------------------------------------------------------------------------------

Name : flow31 Features: mon(Activated) noConfig: Off

Definition: IngrPort(11),SrcDev(0x020b00),DstDev(0x010b00)

Flow Monitor (Activated):

Monitor time: | Mon Sep 05 20:29:08 Localtime 2016 |

---------------------------------------------------------

-----------------------------------------------------------------------------------------------------

| Rx Frames Count | Rx Frames per Sec. | Rx Bytes Count | Rx Throughput(Bps) | Avg Rx Frm Sz(Bytes)|

-----------------------------------------------------------------------------------------------------

| 3.31G | 578.33k | 6.28T | 1.12G | 2084 |

-----------------------------------------------------------------------------------------------------

-------------------------------------------------------------------------------------------------

| I/O Count | I/O Per Sec.(IOPS) | I/O bytes Transferred | I/O bytes Per Sec. |

| Reads / Writes/ Total | Reads / Writes/ Total | Reads / Writes/ Total | Reads / Writes/ Total |

-------------------------------------------------------------------------------------------------

| 0 / 0 / 0 | 0 / 0 / 0 | 0 / 0 / 0 | 0 / 0 / 0 |

-------------------------------------------------------------------------------------------------

Name : flow1 Features: gen(Activated) noConfig: Off

Definition: IngrPort(10),SrcDev(0x020a00),DstDev(0x010a00)

Flow Generator (Activated):

-----------------------

| SrcDev | DstDev |

-----------------------

| 0x020a00 | 0x010a00 |

-----------------------

Number of frames generated from IngrPort : 4.17G

Name : flow3 Features: gen(Activated) noConfig: Off

Definition: IngrPort(11),SrcDev(0x020b00),DstDev(0x010b00)

Flow Generator (Activated):

-----------------------

| SrcDev | DstDev |

-----------------------

| 0x020b00 | 0x010b00 |

-----------------------

Number of frames generated from IngrPort : 1.16G

Name : sys_gen_all_simports Features: gen(Deactivated) noConfig: Off

Definition: IngrPort(*),EgrPort(*),SrcDev(*),DstDev(*)

No data is available for the specified flow-feature combinations.

Page 89: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 89

B154-6510:admin> flow --show all

Name : flow21 Features: mon(Activated) noConfig: Off

Definition: IngrPort(10),SrcDev(0x010a00),DstDev(0x020a00)

Flow Monitor (Activated):

Monitor time: | Mon Sep 05 20:41:33 Localtime 2016 |

---------------------------------------------------------

-----------------------------------------------------------------------------------------------------

| Rx Frames Count | Rx Frames per Sec. | Rx Bytes Count | Rx Throughput(Bps) | Avg Rx Frm Sz(Bytes)|

-----------------------------------------------------------------------------------------------------

| 3.25G | 623.55k | 6.16T | 1.20G | 2084 |

-----------------------------------------------------------------------------------------------------

-------------------------------------------------------------------------------------------------

| I/O Count | I/O Per Sec.(IOPS) | I/O bytes Transferred | I/O bytes Per Sec. |

| Reads / Writes/ Total | Reads / Writes/ Total | Reads / Writes/ Total | Reads / Writes/ Total |

----------------------------------------------------------------------------------------------- --

| 0 / 0 / 0 | 0 / 0 / 0 | 0 / 0 / 0 | 0 / 0 / 0 |

-------------------------------------------------------------------------------------------------

Name : flow41 Features: mon(Activated) noConfig: Off

Definition: IngrPort(11),SrcDev(0x010b00),DstDev(0x020b00)

Flow Monitor (Activated):

Monitor time: | Mon Sep 05 20:41:33 Localtime 2016 |

---------------------------------------------------------

-----------------------------------------------------------------------------------------------------

| Rx Frames Count | Rx Frames per Sec. | Rx Bytes Count | Rx Throughput(Bps) | Avg Rx Frm Sz(Bytes)|

-------------------------------------------------------------------------------------------------- ---

| 3.40G | 576.99k | 6.45T | 1.11G | 2084 |

-----------------------------------------------------------------------------------------------------

-------------------------------------------------------------------------------------------------

| I/O Count | I/O Per Sec.(IOPS) | I/O bytes Transferred | I/O bytes Per Sec. |

| Reads / Writes/ Total | Reads / Writes/ Total | Reads / Writes/ Total | Reads / Writes/ Total |

-------------------------------------------------------------------------------------------------

| 0 / 0 / 0 | 0 / 0 / 0 | 0 / 0 / 0 | 0 / 0 / 0 |

-------------------------------------------------------------------------------------------------

Name : sys_mon_all_fports Features: mon(Deactivated) noConfig: Off

Definition: IngrPort(*),SrcDev(*),DstDev(*)

No data is available for the specified flow-feature combinations.

Name : flow2 Features: gen(Activated) noConfig: Off

Definition: IngrPort(10),SrcDev(0x010a00),DstDev(0x020a00)

Flow Generator (Activated):

-----------------------

| SrcDev | DstDev |

-----------------------

| 0x010a00 | 0x020a00 |

-----------------------

Number of frames generated from IngrPort : 456.35M

Name : flow4 Features: gen(Activated) noConfig: Off

Definition: IngrPort(11),SrcDev(0x010b00),DstDev(0x020b00)

Flow Generator (Activated):

-----------------------

| SrcDev | DstDev |

-----------------------

| 0x010b00 | 0x020b00 |

-----------------------

Number of frames generated from IngrPort : 1.29G

Name : sys_gen_all_simports Features: gen(Deactivated) noConfig: Off

Definition: IngrPort(*),EgrPort(*),SrcDev(*),DstDev(*)

No data is available for the specified flow-feature combinations.

Page 90: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 90

Name : sys_analytics_vtap Features: mir(Deactivated) noConfig: Off

Definition: IngrPort(*),FrameType(firstresp),BiDir

No data is available for the specified flow-feature combinations.

Flow Rx Throughput(Bps) QoS zone-based

Flow11 1.20G QOSH1_zone

Flow21 1.20G QOSH1_zone

Flow31 1.12G QOSL2_zone Flow41 1.11G QOSL2_zone There is a little traffic limiting for low priority traffic(QOSL2_zone) with QoS zone-based traffic prioritization. If I use “portcfgqos --setratelimit 10 200” on B153-6510 Rx_Throughput(Bps) changes: Flow Rx Throughput(Bps) QoS zone-based

Flow11 23.78M QOSH1_zone

Flow21 1.21G QOSH1_zone

Flow31 1.56G QOSL2_zone Flow41 1.12G QOSL2_zone

Page 91: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 91

Virtual fabric test Scheme for VF test

SW 6510 #1B153-6510

Logical switch 1(default logical switch FID 128)

Logical switch 2(FID 1)

Port 0,1,2,3,10,11

Port 4-9,12-47

Logical switch 3(default logical switch FID 128)

Logical switch 4(FID 1)

Port 0,1,2,3,10,11

Port 4-9,12-47

Port 0,1,2,3 are trunked4x8G=32G

Port 0,1,2,3 are trunked4x8G=32G

SW 6510 #2B154-6510

MS-100EDUT #1

Port Client #1Client #2Client #3Client #4 Port Line

MS-100EDUT #2

Port Client #1Client #2Client #3Client #4Port Line

Page 92: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 92

Page 93: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 93

switch_1:FID1:admin> flow --show all

Name : flow11 Features: mon(Activated) noConfig: Off

Definition: IngrPort(10),SrcDev(0x010300),DstDev(0x020300)

Flow Monitor (Activated):

Monitor time: | Tue Sep 06 04:57:08 Localtime 2016 |

---------------------------------------------------------

-----------------------------------------------------------------------------------------------------

| Rx Frames Count | Rx Frames per Sec. | Rx Bytes Count | Rx Throughput(Bps) | Avg Rx Frm

Sz(Bytes)|

-----------------------------------------------------------------------------------------------------

| 3.28G | 802.01k | 6.23T | 1.55G | 2084 |

-----------------------------------------------------------------------------------------------------

-------------------------------------------------------------------------------------------------

| I/O Count | I/O Per Sec.(IOPS) | I/O bytes Transferred | I/O bytes Per Sec. |

| Reads / Writes/ Total | Reads / Writes/ Total | Reads / Writes/ Total | Reads / Writes/ Total |

-------------------------------------------------------------------------------------------------

| 0 / 0 / 0 | 0 / 0 / 0 | 0 / 0 / 0 | 0 / 0 / 0 |

-------------------------------------------------------------------------------------------------

=====================================================================

===================================================

Name : flow31 Features: mon(Activated) noConfig: Off

Definition: IngrPort(11),SrcDev(0x010400),DstDev(0x020400)

Flow Monitor (Activated):

Monitor time: | Tue Sep 06 04:57:08 Localtime 2016 |

---------------------------------------------------------

-----------------------------------------------------------------------------------------------------

| Rx Frames Count | Rx Frames per Sec. | Rx Bytes Count | Rx Throughput(Bps) | Avg Rx Frm

Sz(Bytes)|

-----------------------------------------------------------------------------------------------------

| 3.27G | 802.01k | 6.20T | 1.55G | 2084 |

-----------------------------------------------------------------------------------------------------

-------------------------------------------------------------------------------------------------

| I/O Count | I/O Per Sec.(IOPS) | I/O bytes Transferred | I/O bytes Per Sec. |

| Reads / Writes/ Total | Reads / Writes/ Total | Reads / Writes/ Total | Reads / Writes/ Total |

-------------------------------------------------------------------------------------------------

| 0 / 0 / 0 | 0 / 0 / 0 | 0 / 0 / 0 | 0 / 0 / 0 |

-------------------------------------------------------------------------------------------------

Name : flow1 Features: gen(Activated) noConfig: Off

Definition: IngrPort(10),SrcDev(0x010300),DstDev(0x020300)

Flow Generator (Activated):

-----------------------

| SrcDev | DstDev |

-----------------------

Page 94: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 94

| 0x010300 | 0x020300 |

-----------------------

Number of frames generated from IngrPort : 617.22M

=====================================================================

===================================================

Name : flow3 Features: gen(Activated) noConfig: Off

Definition: IngrPort(11),SrcDev(0x010400),DstDev(0x020400)

Flow Generator (Activated):

-----------------------

| SrcDev | DstDev |

-----------------------

| 0x010400 | 0x020400 |

-----------------------

Number of frames generated from IngrPort : 608.34M

Name : sys_gen_all_simports Features: gen(Deactivated) noConfig: Off

Definition: IngrPort(*),EgrPort(*),SrcDev(*),DstDev(*)

No data is available for the specified flow-feature combinations.

switch_2:FID1:admin> flow --show all

Name : flow21 Features: mon(Activated) noConfig: Off

Definition: IngrPort(10),SrcDev(0x020300),DstDev(0x010300)

Flow Monitor (Activated):

Monitor time: | Tue Sep 06 04:58:28 Localtime 2016 |

---------------------------------------------------------

-----------------------------------------------------------------------------------------------------

| Rx Frames Count | Rx Frames per Sec. | Rx Bytes Count | Rx Throughput(Bps) | Avg Rx Frm

Sz(Bytes)|

-----------------------------------------------------------------------------------------------------

| 3.33G | 801.10k | 6.31T | 1.55G | 2084 |

-----------------------------------------------------------------------------------------------------

-------------------------------------------------------------------------------------------------

| I/O Count | I/O Per Sec.(IOPS) | I/O bytes Transferred | I/O bytes Per Sec. |

| Reads / Writes/ Total | Reads / Writes/ Total | Reads / Writes/ Total | Reads / Writes/ Total |

-------------------------------------------------------------------------------------------------

| 0 / 0 / 0 | 0 / 0 / 0 | 0 / 0 / 0 | 0 / 0 / 0 |

-------------------------------------------------------------------------------------------------

Name : flow41 Features: mon(Activated) noConfig: Off

Definition: IngrPort(11),SrcDev(0x020400),DstDev(0x010400)

Flow Monitor (Activated):

Monitor time: | Tue Sep 06 04:58:28 Localtime 2016 |

---------------------------------------------------------

-----------------------------------------------------------------------------------------------------

| Rx Frames Count | Rx Frames per Sec. | Rx Bytes Count | Rx Throughput(Bps) | Avg Rx Frm

Sz(Bytes)|

-----------------------------------------------------------------------------------------------------

| 3.29G | 801.10k | 6.24T | 1.55G | 2084 |

-----------------------------------------------------------------------------------------------------

-------------------------------------------------------------------------------------------------

| I/O Count | I/O Per Sec.(IOPS) | I/O bytes Transferred | I/O bytes Per Sec. |

Page 95: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 95

| Reads / Writes/ Total | Reads / Writes/ Total | Reads / Writes/ Total | Reads / Writes/ Total |

-------------------------------------------------------------------------------------------------

| 0 / 0 / 0 | 0 / 0 / 0 | 0 / 0 / 0 | 0 / 0 / 0 |

-------------------------------------------------------------------------------------------------

Name : sys_mon_all_fports Features: mon(Deactivated) noConfig: Off

Definition: IngrPort(*),SrcDev(*),DstDev(*)

No data is available for the specified flow-feature combinations.

Name : flow2 Features: gen(Activated) noConfig: Off

Definition: IngrPort(10),SrcDev(0x020300),DstDev(0x010300)

Flow Generator (Activated):

-----------------------

| SrcDev | DstDev |

-----------------------

| 0x020300 | 0x010300 |

-----------------------

Number of frames generated from IngrPort : 364.85M

Name : flow4 Features: gen(Activated) noConfig: Off

Definition: IngrPort(11),SrcDev(0x020400),DstDev(0x010400)

Flow Generator (Activated):

-----------------------

| SrcDev | DstDev |

-----------------------

| 0x020400 | 0x010400 |

-----------------------

Number of frames generated from IngrPort : 359.40M

Name : sys_gen_all_simports Features: gen(Deactivated) noConfig: Off

Definition: IngrPort(*),EgrPort(*),SrcDev(*),DstDev(*)

No data is available for the specified flow-feature combinations.

Name : sys_analytics_vtap Features: mir(Deactivated) noConfig: Off

Definition: IngrPort(*),FrameType(firstresp),BiDir

No data is available for the specified flow-feature combinations.

Flow Rx Throughput(Bps)

Flow11 1.55G Flow21 1.55G Flow31 1.55G Flow41 1.55G

Page 96: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 96

6 TEST BED DATA AND TEST RESULTS

6.1 Contact Details

Test Requestor T8, LLC

Brocade Data Center Ready Lead

Requestor Contact Sokolov Sergey <[email protected]>

6.2 Device Under Test (DUT) Details

Product Volga multiservice DWDM platform, V3 Shelf

Card MS-100E-T10-01

Protocol 8GFC

Revision HwNumber 1.0

SwNumber 1.0.4

Distance Tested 70 km

Comments -

6.3 Brocade Products

Switch Model Version Protocol Comments

#1

Brocade DCX 8510

Backbone

Kernel: 2.6.14.2

Fabric OS: v7.4.1c

Made on: Tue Apr 19 03:27:56 2016

Flash: Fri Jul 22 12:54:28 2016

BootProm: 1.0.16

8GFC -

#2

Brocade DCX 8510

Backbone

Kernel: 2.6.14.2

Fabric OS: v7.4.1c

Made on: Tue Apr 19 00:27:56 2016

Flash: Fri Jul 15 19:37:47 2016

BootProm: 1.0.16

8GFC -

#3

Brocade SW 6510

Kernel: 2.6.14.2

Fabric OS: v7.3.0b

Made on: Mon Oct 13 19:21:44 2014

Flash: Tue Oct 28 15:45:03 2014

BootProm: 1.0.11

8GFC -

#4

Brocade SW 6510

Kernel: 2.6.14.2

Fabric OS: v7.4.0a

Made on: Fri May 29 01:45:37 2015

Flash: Tue Jun 16 16:41:01 2015

BootProm: 1.0.11

8GFC -

Page 97: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 97

6.4 Test Cases and Results

Networked Solutions (including MAN/WAN): Product (DUT) and Switch Details, Test Results

Networked Solution (including MAN/WAN) Product Details

Vendor T8 LLC

Product Volga multiservice DWDM platform, V3 Shelf

Type MS-100E-T10-01

Firmware/code HwNumber 1.0

SwNumber 1.0.4

FC port default topology -

FC port default speed 8GFC/10GFC

FC port supported speeds 8GFC/10GFC

Networked Solution (including MAN/WAN) Tests and Results

Test Case Result

(Pass/Fail)

MS-100E-T10

4.1.1 DUT Reset Test N/A See Note 1

4.1.2 DUT Port Disable/Enable Test N/A See Note 1

4.1.3 DUT Cable Disconnect/Reconnect Test N/A See Note 1

4.1.4 DUT Port Speed Lock Test N/A See Note 1

4.1.5 Switch Reset Test N/A See Note 1

4.1.6 Uninterrupted I/O Test (12 h) N/A See Note 1

5.7.1 SAN Extension Tests. VC_RDY MODE:

5.7.1.1 E-Port Disable/Enable Test Pass Pass

5.7.1.2 E-Port Cable Disconnect/Reconnect Test Pass Pass

5.7.1.3 LH Network Failure (No Redundancy) Pass Pass

5.7.1.4 LH Network Failure (With Redundancy) N/A See Note 2

5.7.1.5 Switch Reboot Test Pass Pass

5.7.1.6 DUT Reset Test Pass Pass

5.7.1.7 Extended Duration I/O Test (12h) Pass Pass

Page 98: Compatibility Test Report: SAN Extensiont8.ru/wp-content/uploads/2016/11/Compatibility...Transmits 10×10 Gbit/s client signals in 100 Gbit/s DWDM channel with Soft-FEC Transmits 10

Т8 for Brocade Data Center Ready

Compatibility Test Report T8 Page 98

5.7.1.8 ISL Trunking Test Pass Pass

5.7.1.9 16G ISL FEC Test N/A See Note 3

5.7.1.10 16G ISL D port Test Pass Pass (8G)

5.7.1.11 16G ISL Compression Test Pass Pass (8G)

5.7.1.12 16G ISL Encryption Test Pass Pass (8G)

5.7.1 SAN Extension Tests. R_RDY MODE:

5.7.1.1 E-Port Disable/Enable Test Pass Pass

See Note 4

5.7.1.2 E-Port Cable Disconnect/Reconnect Test Pass Pass

See Note 4

5.7.1.3 LH Network Failure (No Redundancy) Pass Pass

See Note 4

5.7.1.4 LH Network Failure (With Redundancy) N/A See Note 2

5.7.1.5 Switch Reboot Test Pass Pass

See Note 4

5.7.1.6 DUT Reset Test Pass Pass

See Note 4

Additional tests:

Test for trunked configuration Pass Pass

See Note 4

Hareboot test Pass Pass

See Note 4

QoS test Pass Pass

See Note 4

Virtual fabric test Pass Pass

See Note 4

Note 1: “4.1 DUT initialization tests” do not applicable for MS-100E-T10 card because MS-100E-T10 card support levels FC-0, FC-1 according to rec. G.709.

Note 2: DUT (MS-100E-T10 card) does not support test configuration.

Note 3: FEC is not supported at 8G. Note 4: SW 6510 was used in this test.