 INS_CNFE6+2USPOE_REV– 07/08/11 PAGE 1 INSTALLATION AND OPERATION MANUAL CNFE6+2USPOE 10/100TX Drop/Insert/Repeat 6TX/2FX Ethernet Switch with PoE The ComNet CNFE6+2USPOE provides 8 Ethernet ports operating at 10/100 Mbs and is designed to combine six electrical ports into a second optical port that forwards this data to the next CNFE6+2USPOE. The optical ports are designed to forward the data from the six electrical ports to its up network. In addition, the electrical ports can supply up to thirty (30) watts of power (“Power Over Ethernet”), based on IEEE802.3at standard, to remote Ethernet devices. This product uses ST optical connections and can be supplied to operate over Singlemode or Multimode optical fiber. There is no programming required to use this product. It is “Plug-and-Play”. Port 8 can be used to monitor the data flow from the optical port to permit “local” observation and diagnostics of the equipment when the diagnostic switch is set to on. LED indicators confirm the operating status of this device. The ComNet CNFE6+2USPOE may be either wall mounted, rack mounted (“ComFit” packaging) or DIN-rail mounted with the use of the ComNet DINBKT1 adapter. See Figures A on Page 5 for mounting instructions. See Figures 1 – 7 for complete installation details.

description

Buy the ComNet CNFE6+2USPOES at JMAC Supply!https://www.jmac.com/ComNet_CNFE6_PLUS2USPOES_p/comnet-cnfe62uspoes.htm?=scribd

Transcript of ComNet CNFE6+2USPOES Instruction Manual

  • INS_CNFE6+2USPOE_REV07/08/11

    PAGE 1

    INSTALLATION AND OPERATION MANUAL

    CNFE6+2USPOE10/100TX Drop/Insert/Repeat 6TX/2FX Ethernet Switch with PoE

    The ComNet CNFE6+2USPOE provides 8 Ethernet ports operating at 10/100 Mbs and is designed to combine six electrical ports into a second optical port that forwards this data to the next CNFE6+2USPOE. The optical ports are designed to forward the data from the six electrical ports to its up network. In addition, the electrical ports can supply up to thirty (30) watts of power (Power Over Ethernet), based on IEEE802.3at standard, to remote Ethernet devices. This product uses ST optical connections and can be supplied to operate over Singlemode or Multimode optical fiber.

    There is no programming required to use this product. It is Plug-and-Play. Port 8 can be used to monitor the data flow from the optical port to permit local observation and diagnostics of the equipment when the diagnostic switch is set to on. LED indicators confirm the operating status of this device. The ComNet CNFE6+2USPOE may be either wall mounted, rack mounted (ComFit packaging) or DIN-rail mounted with the use of the ComNet DINBKT1 adapter. See Figures A on Page 5 for mounting instructions.

    See Figures 1 7 for complete installation details.

  • INS_CNFE6+2USPOE_REV07/08/11

    PAGE 2

    FIGURE 1 TYPICAL APPLICATION

    INSTALLATION AND OPERATION MANUAL CNFE6+2USPOE

    TECh SUPPORT: 1.888.678.9427

    CNFE6+2USPOE CNFE6+2USPOE

    PC 5 61 148VDC in

    48VDC in

    2345678

    2345678

    ... ...

    ... ......

    ... ...... ...

    10/100TX

    Ethernet

    Ethernet

    10/100TX

    PoE

    PoE

    INSERTINSERT

    FiberFiberFiber

    11Up layer switch with

    1Gbps enabled

  • INS_CNFE6+2USPOE_REV07/08/11

    PAGE 3

    NOTE: Remove Electrical Connector for Rack Mount Units

    OPTICAL FIBER

    RJ-45

    RJ-45

    RJ-45

    RJ-45

    BLACK

    BLACK WITH WHITE STRIPE

    For Power over Ethernet, use

    48 VDC @ 5 Amps PS. (ComNet Model PS48VDC-5ADIN

    sold separately)

    NOTE: Diagnostic only functions when Uplink is enabled. When Uplink and Diagnostic are enabled, Port 8 can be connected to all other ports from 1 7.

    FIGURE 3 CNFE6+2USPOE

    FIGURE 2 CNFE6+2USPOE

    INSTALLATION AND OPERATION MANUAL CNFE6+2USPOE

    REAR PANELFRONT PANEL

    TECh SUPPORT: 1.888.678.9427

    FIGURE 4 REAR SWITCH SETTINGS

    EFFECT PORT Uplink

    DIAGNOSTIC

    Uplink & Diagnostic Enabled ON ON

    Uplink Enabled, Diagnostic Disabled ON OFF

    Uplink & Diagnostic Disabled OFF ON

    Uplink & Diagnostic Disabled OFF OFF

  • INS_CNFE6+2USPOE_REV07/08/11

    PAGE 4

    INSTALLATION AND OPERATION MANUAL CNFE6+2USPOE

    TECh SUPPORT: 1.888.678.9427

    FIGURE 5 LED INDICATORS

    LINK (PORT 1 & 2) LINK (PORT 3 8) POE (PORT 3 8) POWER

    SOLID Link Up Link Up Power Suppled to PD Power Applied

    BLINKING Data Activity Data Activity POE Negotiating

    OFF No Data Link No Data Link No Power Supplied Power Not Applied

    FIGURE 6 APPLICATION DIAGRAM WITHOUT MULTICAST TRAFFICIGMP Disabled, Uplink disabled on the units.

    P1

    PC Connections on Ports 38

    CNGE2FE24MODMS

    CNFE6+2USPOE CNFE6+2USPOE

    CNFE6+2USPOE

    P1

    P1

    P2

  • INS_CNFE6+2USPOE_REV07/08/11

    PAGE 5

    INSTALLATION AND OPERATION MANUAL CNFE6+2USPOE

    TECh SUPPORT: 1.888.678.9427

    FIGURE 7 APPLICATION DIAGRAM WITH MULTICAST TRAFFICIGMP Enabled, Uplink enabled on the units

    P1

    Camera Connections Providing PoEon Ports 38

    CNGE2FE24MODMS

    CNFE6+2USPOE

    P1

    P1

    P2

  • INS_CNFE6+2USPOE_REV07/08/11

    PAGE 6 2012 Communications Networks Corporation. All Rights Reserved. ComNet and the ComNet Logo are registered trademarks of Communication Networks, LLC.

    3 CORPORATE DRIVE | DANBURy, CT 06810 | USA T: 203.796.5300 | F: 203.796.5303 | TECh SUPPORT: 1.888.678.9427 | [email protected]

    8 TURNBERRy PARK ROAD | GILDERSOME | MORLEy | LEEDS, UK LS27 7LET: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | [email protected]

    MEChANICAL INSTALLATION INSTRUCTIONS

    .313 [7.95 mm]

    .156 [3.96 mm]

    FIGURE ADimensions are for a standard ComNet two slot module

    INSTALLATION CONSIDERATIONS This fiber-optic link is supplied as a Standalone/Rack module. Units should be installed in dry locations protected from extremes of temperature and humidity.

    C1-US, C1-EU, C1-AU OR C1-Ch CARD CAGE RACKS CAUTION: Although the units are hot-swappable and may be installed without turning power off to the rack, ComNet recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack.

    1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the racks connector panel. Seating may require thumb pressure on the top and bottom of the cards front panel.

    CAUTION: Take care not to press on any of the LEDs. 2. Tighten the two thumb screws on the card until the front panel of the

    card is seated against the front of the rack.

    WARNING: Unit is to be used with a Listed Class 2 or LPS power supply.

    IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack

    assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.

    B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.