Comandos uteis M2000
-
Upload
joao-lopes -
Category
Documents
-
view
31 -
download
0
description
Transcript of Comandos uteis M2000
Template.TXT//Estado do link para o MME
DSP SCTPLNK:SCTPNO=0;
//Verificar tipo fisico de transmissão
DSP ETHPORT: SN=7, SBT=BASE_BOARD;
//Verificar estado de ligaçãoDSP OMCH:FLAG=MASTER;
//Listar rotas configuradas no eNodeBLST IPRT:;
//Verificar tipo de relogioDSP CLKSRC:;
//Verificar valores de sincronismoDSP CLKDA:SRN=1,SN=7;
//Verificar estado do sincronismoDSP CLKSTAT:SRN=1,SN=7;
//Listar caracteristicas do hardware, nºserie, etc..DSP BRDMFRINFO:CN=0,SRN=4,SN=0;
//Verificar tipo fisico de transmissãoDSP ETHPORT: SN=7, SBT=BASE_BOARD;
//Verificar potencia oticaDSP SFP: CN=0, SRN=0, SN=7, MODULEID=0;
DSP SFP: CN=0, SRN=60, SN=0, MODULEID=0;DSP SFP: CN=0, SRN=61, SN=0, MODULEID=0;DSP SFP: CN=0, SRN=62, SN=0, MODULEID=0;
DSP SFP: CN=0, SRN=0, SN=3, MODULEID=0;DSP SFP: CN=0, SRN=0, SN=3, MODULEID=2;DSP SFP: CN=0, SRN=0, SN=3, MODULEID=4;
//Verificar sectoresLST SECTOR;LST CELL;LST RRU;
//Verificar sectoresDSP SECTOR;DSP CELL;DSP RRU;
Página 1
Template.TXT
//TMA, RET'S
//TMA'SDSP TMADEVICEDATA
MOD ANTENNAPORT: CN=0, SRN=62, SN=0, PN=R0A, PWRSWITCH=ON, THRESHOLDTYPE=TMA24DB_AISG;
MOD ANTENNAPORT: CN=0, SRN=62, SN=0, PN=R0B, PWRSWITCH=ON, THRESHOLDTYPE=TMA24DB_AISG;
SCN ALD: CTRLPORTSRN=62, CTRLPORTSN=0;
ADD TMA: DEVICENO=3, DEVICENAME="TMA3", CTRLPORTCN=0, CTRLPORTSRN=62, CTRLPORTSN=0, SUBUNITNUM=2, CONNCN1=0, CONNSRN1=62, CONNSN1=0, CONNPN1=R0A, CONNCN2=0, CONNSRN2=62, CONNSN2=0, CONNPN2=R0B;
//RET'SSCN ALD: CTRLPORTSRN=60, CTRLPORTSN=0;
//Colocar "VENDERCODE" E "SERIALNO" que foi dado no comando anteriorADD RET: DEVICENO=4, DEVICENAME="RET_SECTOR1", CTRLPORTCN=0, CTRLPORTSRN=60, CTRLPORTSN=0, RETTYPE=SINGLE_RET, POLARTYPE=SINGLE, SCENARIO=REGULAR, VENDORCODE="XX", SERIALNO="XXX";
//Download do software do RET (KATHREIN)DLD RETCFGDATA:OPMODE=SUBUNIT,DEVICENO=4,SUBUNITNO=1,IP="10.103.49.212",USR="root",PWD="root",SRCF="KA_80010644_2490‐2690_extended2.bin";
MOD RETSUBUNIT: DEVICENO=4, SUBUNITNO=1, CONNCN1=0, CONNSRN1=60, CONNSN1=0, CONNPN1=R0A, CONNCN2=0, CONNSRN2=60, CONNSN2=0, CONNPN2=R0B;
CLB RET: OPMODE=SUBUNIT, DEVICENO=4, SUBUNITNO=1;
DSP RETDEVICEDATA: DEVICENO=4, SUBUNITNO=1;
MOD RETTILT: METHODS=BY_RET, DEVICENO=4, TILT=70;
LST RETSUBUNIT:;
Página 2