Colorimetric Tubes Drager

41
DRAEGER SAFETY GT-MMT „DRAEGER TUBES“ • 31.12.2004 1/41 DRAEGER-TUBES® - MEASUREMENT SYSTEMS INDEX

description

Drager Tubes

Transcript of Colorimetric Tubes Drager

Page 1: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 1/41

DRAEGER-TUBES® - MEASUREMENT SYSTEMS

INDEX

Page 2: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 2/41

“A detector tube is a hermetically sealed glass tube containing an inert solid or granular material such as silica gel, alumina,resin, pumice, or ground glass.

The inert material is impregnated with or mixed with one or more reagents which change color when specific types of air contaminants are introduced.

The length of the color change or stain, or the intensity of color change as compared to a comparative standard indicates the amount of material present.”

Source: Air Monitoring Instrumentation, C. J. Maslansky/S. P. Maslansky

WHAT IS A DETECTOR TUBE?

Page 3: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 3/41

• Glass Vial (120 x 7 mm)

• Filled with a chemical reagent (s)

• Air is pulled through with a hand operated pump

• The reagents change color if the targeted chemical is present

WHAT IS A DETECTOR TUBE?

Page 4: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 4/41

• More than 200 Draeger-Tubes

• Detecting more than 500 substances

• Measurements in air, liquids, and soil

• Gases (CO, H2S, Cl2,…)

• Vapors (acetone, benzene, ethyl alcohol,…)

• Aerosols (nickel, sodium cyanide,sulfuric acid,…)

DRAEGER-TUBE CAPABILITIES

Example

Page 5: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 5/41

• Extremely portable and easy to use.

• Can be specific to a chemical or detect general family of gases.

• Can measure low/sub ppm levels to Vol. %.

• Can be used to determine an unknown or the chemical group (aromatic, aliphatic, alcohol).

• Accuracy varies from +/- 5 to 25 % depending on gas and measuring range.

DRAEGER-TUBE CAPABILITIES

Page 6: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 6/41

Carbon Monoxide 10/b (10 - 3,000 ppm)

• Gas / Vapor to be detected

• Indicates lowest standard measuring range

• Indicates latest engineering revision

• Specifies measuring range

• ppm, Vol %, mg/m3, mg/l, lbs/mmcf, or qualitative

DRAEGER-TUBE NOMENCLATURE

Page 7: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 7/41

• Carbon Monoxide 10/b Short-term

• Carbon Monoxide 10/a-L Long-term

• Carbon Monoxide 50/a-D Diffusion

• Carbon Monoxide 5/a-P Aerotest

Diffusion Tubes

DRAEGER-TUBE NOMENCLATURE

Page 8: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 8/41

• Short-Term Tubes

• Gases, vapors, & aerosols - white label

• Single Stroke - Gases & Vapors - orange label

• Long-Term Tubes

• Active - yellow label (-L)

• Passive (Dosimeter) - magenta label (-D)

• Sorbent Tubes (silica gel, charcoal) – green label

• Compressed Air Testing - blue label (-P)

DRAEGER-TUBE TYPES

Page 9: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 9/41

• Batch / Lot Number

• Total Number of Tests (10, 9, 8, 5)

• Tube Type

• Tube Nomenclature in 4 Languages

• Measuring Range

• ISO 9001

• Storage Temperature (25 °C / 77°F)

• Expiration Date

INFORMATION ON THE BOX

Page 10: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 10/41

• Nomenclature

• Part Number*

• Batch / Lot Number*

• Number of Pump Strokes

• Airflow Directional Arrow

• Measurement Scale(s) or color intensity layer

* Consider for questions on a particular batch.

WHAT'S ON THE TUBE?

Page 11: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 11/41

• Scaled Tubes

• Color Comparison Tubes

• Color Match Tubes

• Qualitative Tubes

• Ampoule Tubes

• Two Tube Systems

• Double Tube Systems

• Single Stroke Tubes

• Simultaneous Test Sets

SHORT-TERM DRAEGER-TUBE

Page 12: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 12/41

Draeger

Water Vapor 1/b

n=

2

15

10

5

3

1

Airflow directional arrow

Tube nomenclature indicates gas to be measured

Determine reading using the length of color stain

Number of pump strokesBatch: ARHM - 0111

(Aim towards pump inlet)

Quality control batch number

8101781

Part number

Hermetically-sealed glass tube housing

DRAEGER-TUBES

Page 13: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 13/41

• Adequate lighting - but no direct sunlight• Hold the tube against a light background• Scale tubes:

a) full length of discoloration(sum of all colors)

b) diffuse indication(end point of the slightest discoloration)

• Compare with an unused tube• Diagonal leading edge:

average between the shortest andlongest discoloration

READING DRAEGER-TUBES

Page 14: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 14/41

• Operating Instructions

• Draeger-Tube Handbook

• VOICE Software

MUST be verified by Draeger, DO NOT assume that the measuring range is linear for all sample volumes!

EXTENDING THE MEASUREMENT RANGE

Page 15: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 15/41

Conversion of semantics:

ppm = ml/m³ mg/m³

C [ppm] = c [mg/m³] x 24.1 *)

Molar mass [g]

C [mg/m³] = c [ppm] x Molar mass [g]

24.1 *)

*) 24.1 L Mole volume at 20°C and 1013 hPa

MEASUREMENT OF GASESBASICS

Page 16: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 16/41

ppm = parts per million ml/m3 or l / 1 miol.

Vol.% = Liters of Contaminant100 Liters of Air

1 Vol.% = 10,000 ppm

ppm = mg x 24m3 x MW (at 20 °C, 68 °F)

MW=>molecular weight (g/mole) & 24 => mole volume (moles/L)

UNITS OF MEASUREMENT

Page 17: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 17/41

Draeger-Tubes (7 mm)

• Less Cross-Sensitivity• Shorter Testing Time...

e.g. NH3 5-70 ppm, 1 minute• More Distinct Length of Stain...

e.g. CO 2-60 ppm, 25 mm @ TLV

• Longer Shelf-Life (2 Years)• No Cold Storage Requirement...

0 to 25 °C (0 to 77 °F)• Advanced Tube Designs• Quality Control Batch Testing• ISO 9001 Certification • Detecting >500 substances

DRAEGER TUBE ADVANTAGES

5 mm Tubes

• Higher Cross-Sensitivity• Longer Testing Time

e.g. NH3 10-50 ppm, 3.5 minutes• Shorter Length of Stain

e.g. CO 5-50 ppm, 11 mm @ TLV• Ambiguous Shelf-Life• Cool Storage Requirement

0 to 15 °C (0 to 50 °F)require Pyrolyzer

• Batch Testing• ISO 9001 Certification

Page 18: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 18/41

Ü Draeger detector tubes and gas detection pumps are designed and calibrated as a unit.

Ü Interchanging Draeger pumps and tubes with other manufacturer’s products is not recommended nor permitted according to official regulations (e.g. ANSI / ISEA 102-1990, R 1998 or EN 1231)

WARNING !!!

Page 19: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 19/41

-- --

Pump stroke counter

Airflow directional arrow

End of stroke indicator

(Facing pump inlet)

Scissors & spring mechanisms provides uniform pump stroke

Durable EPDM rubber housing

Exhaust port

Allen screw for pump maintenance

Wrist strap

Ceramic tube opener

Bellows-style pump

AREL - F012

Quality control batch number

DRAEGER ACCURO PUMP

Page 20: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 20/41

• Insert unopened Draeger detector tube into socket.

• Squeeze pump completely and release.

• Pump is adequately leak proof if the end-of-strokeindicator has not appeared (popped up) after 15minutes.

• if the end-of-stroke indicator appears within 15 minutes:

1. Clean the exhaust valve and valve seating area2. Replace the exhaust valve3. Replace the socket

ACCURO LEAK TEST & CALIBRATION CHECKLEAK TEST PROCEDURE

Page 21: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 21/41

Draeger Pump

• Distinct end-of-stroke indicator• Automatic stroke counter• No O-rings to lubricate...• leakage not a problem• No frictional wear & tear parts• Simple leak test

Faster opening time per stroke• typically < 20 seconds• Optional one-hand operation

DRAEGER PUMP ADVANTAGES

Piston Pump

• Indicator at end of handle• manual stroke counter• O-Rings requiring lubrication• small particles can cause leaks

must maintain lubrication• improper procedure can damage

check valve • more time per stroke

1 to 3 minutes• two hand operation

Page 22: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 22/41

• Device Complete with Internal Pump

• Battery Operated (1,000 Strokes)

• Programmable to 199 Strokes

• Dual LCD Display (Selected & Actual Strokes)

• Microprocessor Controlled

• Rugged Design & Construction

• Intrinsically Safe Approval (CENELEC)

• Low Battery Warning

DRAEGER QUANTIMETER 1000

Page 23: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 23/41

• Extension of measurement range

• Special applications - aerosols & ppb

• Sulfuric Acid

• Dimethyl Sulfate

• High usage, e.g. plant turnaround

• Multi-tasking

• Indoor air applications

• Sampling tubes

APPLICATIONS ACCURO 2000 & QUANTIMETER 1000

Page 24: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 24/41

1. 3,10,15 meter Extension Hoses

2. Hot Air Probe

3. Exhaust Gas Probe

4. Tube Opener

1

2

34

EXTENSION HOSES & PROBES

Page 25: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 25/41

� Pumps Kits

� Simultaneous Test Sets

� HazMat Kit

� HazMat Simultest

� DLE Kit

� Aerotest Kit

DRAEGER TUBE KITS

CDS-Sets

Aerotest-Simultan

Page 26: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 26/41

accuro® Pump

Soft-side Pump Kit

Nylon carry case, accuro

pump, tube opener,

spare parts kit, and tools.

ACCURO PUMP KITS

Example

Page 27: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 27/41

• Set I: Acid Gas, HCN, CO, Basic, NOx

• Set II: SO2, Cl2, H2S, CO2, COCl2

• Set III: Ketones, Aromatics, Alcohols,

Aliphatics, Chlorinated Hydroc.

SIMULTEST SETSDETECT AND MEASURE 5 CHEMICALS SIMULTANEOUSLY

Page 28: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 28/41

Includes the 3 Simultest Sets

• Simple & Fast

• 45 seconds per set!!

• 15 chemicals in < 5 minutes

• No complicated charts

• Reliable Draeger Technology

HAZMAT SIMULTEST SETS

Example

Page 29: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 29/41

Types of chemical agents detected:

• Nerve

• Blister

• Lung

• Blood

• Nose and Throat Irritating

CDS KIT

Page 30: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 30/41

• Low cost vs. spectroscopic devices

• No power supply required

• On-the-spot results in five minutes

• No warm-up time

• No calibration

• Minimal training

• Simple operation

• No filters to replace

• Light weight and portable

CDS KITFEATURES / BENEFITS

Example

Page 31: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 31/41

• Objective: test PID’s, FID’s, Draeger Tubes (Phosphoric Acid Esters 0.05/a & Thioether)

• Agents: Tabun (GA), Sarin (GA), Mustard (HD)

• Temperatures: 0, 20, 40 °C

• Humidities: 0, 50, 90% RH

REPORT OF DETECTORS FOR CW AGENTS

Page 32: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 32/41

No consistent response factor for PID or FID

• The results with the Draeger tubes were consistent and the tubes performed well in all tests.

• None of the detectors would calibrate correctly after the field tests

• Gasoline exhaust, diesel exhaust, gasoline vapor, and diesel vapor adversely affect the sensitivity of the detectors

• Neither Draeger tube showed any positive reactionto the interference vapors tested

REPORT OF DETECTORS FOR CW AGENTS

Page 33: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 33/41

• Simultaneous measurementof CO, CO2, Oil, & H2O

• No calibration (limiting orifice)

• Time savings

• 300 bar = 4500 psi

AEROTEST SIMULTAN HPFEATURES

Page 34: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 34/41

Kit Contents• Pressure Reducer• Measuring Device (4 tubes)• CGA 347 Female Connector• CGA 347 Male Connector• Timer• Deluxe Tube Opener• Instruction Manual• Carrying Case

Four Boxes of Tubes• 6728521, CO2 100/a-P• 6728511, CO 5/ a-P• 6728371, Oil 10 / a-P• 8103061, H2O 20 / a-P

AEROTEST SIMULTAN HP

Page 35: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 35/41

• Aerotest Simultan LP (<10 bar = 150 psi)CO, CO2, H2O, and Oil

• Aerotest Simultan HP (<300 bar = 4500)CO, CO2, H2O, and Oil

• Aerotest Simultan HP + P (<300 bar = 4500 psi)CO, CO2, H2O, and Oil (Navy lubricant)accuro pump

• Aerotest Simultan MultiTest (<5 bar = 75 psi)Measuring device for seven tubesCO, CO2, H2O,Oil, SO2, H2S, and NOx

AEROTEST SIMULTAN VERSIONS

Page 36: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 36/41

• An instrument designed to produce a harmless, non-toxic cloud of smoke rendering even slight air

• currents visible.

• Determination of relative air speed, distribution, and direction.

• General purpose use only ( not intrinsically safe)

"FLOW CHECK" INDICATORWHAT IS IT?

Page 37: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 37/41

• Environmentally safe

• Puffs of smoke or continuous cloud

• Easy to use

• One hand operation

• Light weight

• Ergonomic design

"FLOW CHECK"FEATURES

Page 38: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 38/41

Flow Check Smoke Generation Tube

Non- irritating Irritates mucous membranes

Non-toxic Stannic Chloride, Sulfuric No

H2O needed H2O required for reaction

"FLOW CHECK"COMPETITIVE COMPARISON

Page 39: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 39/41

• Determination of volatile contaminants in water

• Extraction liquid phase and gas phase

• Measurement with Conventional Draeger-Tubes

• On-site results

DLE KIT

Page 40: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 40/41

� Bio-Check F

� Bio-Check Ozone

� Phosphine Badge

� ORSA

DRAEGER BADGES

Page 41: Colorimetric Tubes Drager

DRAEGER SAFETY • GT-MMT„DRAEGER TUBES“ • 31.12.2004 • 41/41

THANK YOU FOR YOUR ATTENTION!INDEX