Cogeneration & trigeneration with gas...
Transcript of Cogeneration & trigeneration with gas...
Cogeneration & Cogeneration & trigenerationtrigeneration
with gas with gas microturbinesmicroturbines
Turbec Turbec S.p.AS.p.A..
Turbec: the historyTurbec: the history
In the early
80s, Volvo started
the development
of two
different
gas turbine systems
for
vehicles
like
cars, bus and trucks
(VT40 and VT100)
Turbec T100: the developmentTurbec T100: the development
First Prototype (1997)
SERIES I (1998-1999)
SERIES II (1999-2001)
SERIES III
(2002-2009)
Turbec T100 Turbec T100
••RellabilityRellability••Low Low maintenancemaintenance
costscosts••Life in Life in operationoperation
(60.000 (60.000 hourshours))••Easy direction of the Easy direction of the equipmentequipment
••FlexibilityFlexibility
on the on the useuse
of the of the heatheat••Easy Easy installationinstallation
••LowerLower
emissionsemissions
valuesvalues••Remote control Remote control optionoption
••FunctioningFunctioning
withwith
differentdifferent
typetype
of of fuelfuel
DimensionsDimensions (CHP)(CHP)900x1810x2527/3652 mm (900x1810x2527/3652 mm (WxHxLWxHxL))
WeightWeight2650 kg 2650 kg
ElectricalElectrical outputoutput100 kW (ISO 100 kW (ISO conditioncondition))ElectricalElectrical efficiencyefficiency 30%30%
ProducedProduced heatheat (hot water)(hot water)167 kW (167 kW (aboutabout 144.000 kcal/h)144.000 kcal/h)ThermalThermal efficiencyefficiency 48% 48%
NoiseNoise levellevel70 70 dBAdBA (at 1 (at 1 metermeter))
VolumetricVolumetric exhaustexhaust gas gas emissionsemissions at at 15% O15% O22 and at 100% and at 100% ofof the the loadload::
NoNoxx <15 ppm v (<32mg/MJ <15 ppm v (<32mg/MJ fuelfuel))CO <15 ppm v (<18mg/MJ CO <15 ppm v (<18mg/MJ fuelfuel))UHC <10 ppm vUHC <10 ppm v
FunctioningFunctioning
Remote controlRemote control
Modem
Central Station
Maintenance Team
Head Office
Administration
Energy trading
Sales
100%ENERGY INPUT(FUEL)
37% ELECTRICITY
CONVENTIONAL SYSTEMTOTAL PERFORMANCE
~ 37%
55 %WASTE HEAT
8 %NETWORK
LOSSES
AnalysisAnalysis
of the of the currentcurrent
situationsituation
OUR SOLUTIONOUR SOLUTION
55% HEAT
COGENERATIONTOTAL PERFORMANCE
~ 30+55 =85%
100%INLET ENERGY(FUEL)
20 %WASTE HEAT
30% ELECTRICITY’
The Turbec The Turbec experienceexperience
450 installed
equipments>4.000.000 functioning
hours
for
the
installed
equipments
Shopping center (7%) Greenhouse (6%)
Ospedali-case riposo (23%)
Hotels (11%)Speciali -Ricerca (16%)
Scuole-Università (4%)
Piscine (6%)
Industria (8%)
Biogas (20%)
Swimming
pools School - University
Specials - Research
Hospitals
Nursing Homes
(23%)
Industry (8%)
Some Some applicationsapplications
Swimming pools : Legnano, Ispra, Monza
ReferencesReferences
Retirement
house (Bergamo -
Italy)
ReferencesReferences
Resort
***** Le Fay
(Lago di Garda -
Italy)
ReferencesReferences
Block of
flats
(300 flats) Milano - Italy
Process
heat
ALENIA INDUSTRIE AERONAVALI (Venezia – Italy)
ReferencesReferences
ReferencesReferences
Fabriano Hospital (Ancona -
Italy)
Trigeneration
shopping center
(Ipercoop
Arca Torino)
ReferencesReferences
Heating
and greenhouses
carbon fertilising
(SW)
ReferencesReferences
ReferencesReferencesElectricElectric
energyenergy
costscosts 0,110,11€€/kWh/kWh
MethaneMethane
costscosts O,35O,35€€/m/m33
ElectricElectric
powerpower 100kW100kW
ThermicThermic
powerpower 160kW160kW
Operating
hours
/year
: 8.000 40.156 €/YEAR
Electric Energy
Thermal Energy
Total Revenues
Hour revenue
Total operation costs
Maintenance costs
Gas cost
Particular
attention
is
given
to
the development
of machines
for
applications
with
fuels
from
renewable
sources, the real
distinguishing
feature
of the microturbine
BIOGAS
EXTERNAL COMBUSTION OF BIOMASS
SOLAR APPLICATION
VEG OIL
Special applicationsSpecial applications
Application modelsApplication models
Biogas Biogas fromfrom
landfilllandfill
(Perugia (Perugia --
Italy)Italy)
Application modelsApplication models
Biogas Biogas fromfrom
digestingdigesting
manuremanure
& & biomassbiomass
BiomassBiomass
––
ExternalExternal
combustioncombustionThe The functioningfunctioning
Special applicationsSpecial applications
BiomassBiomass
––
ExternalExternal
combustioncombustion
((chipschips))(ENEL Livorno (ENEL Livorno ––
Italy)Italy)
Special ApplicationsSpecial Applications
Special ApplicationsSpecial Applications
SolarSolar
applicationapplicationThe The functioningfunctioning
Special ApplicationsSpecial Applications
SolarSolar
ApplicationApplicationPlataformaPlataforma
solarsolar
de Almeria (de Almeria (SpainSpain) )
SolarSolar
ApplicationApplicationKibbutz Kibbutz SamarSamar
(Israel)(Israel)
Special ApplicationsSpecial Applications
Micro CHP Micro CHP ElectricElectric powerpower 5 kW 5 kW
ThermicThermic powerpower 12 kW12 kW
In cooperation with
- 66% CO2
THE GOALTHE GOAL
WITH COGENERATION THE EFFICIENCY INCREASES FROM
37%
TO
85%
ENERGY SAVING EQUAL TO
5.000.000
TON OF PETRO IF USED OVER 100% OF PLANT SYSTEMS
Energency
efficiency
It
is
an
important
environment
protection
factor, enable
saving
on non renewable
energy
sources
and avoiding
emissions
from
fossile fuel
……THANKTHANK YOUYOU
TURBEC S.p.A.
Via Fratelli Bandiera
44042 Cento (FE) Italia
Tel. +39 0516831628
Fax. +39 051901634