Coaxial Cable RG59 DC Cross Section center condcutor insulation braiding jacket Construction Performance Center Center Center Center conductor: conductor: conductor: conductor: Bare copper Electrical Characteristics: AWG: 20 Fequency Attenuation Dia.: 0.813mm (MHz) (db/100m) 1 0.79 Insulation: Insulation: Insulation: Insulation: Foam PE with skin 10 2.5 Norm. thickness: 1.78mm 100 9.05 insulation Dia.: 3.66 +/- 0.08mm 400 19.76 Braiding Braiding Braiding Braiding Shield: Shield: Shield: Shield: bare copper wire Dielectric strength (kv/min) 1.0 Construction: 16*7/0.16mm Impedence (ohms) 75+/-3 Coverage: >= 95% Capacitance (PF/m) 53.1 Cond. DCR at 20 deg. (ohms/km) <=33.9 Jacket: Jacket: Jacket: Jacket: PVC Velocity of propagation (%) >=82 Norm. thickness: 0.80mm Min. thickness: 0.70mm Out Dia. 6.0 +/- 0.1mm Mechanical Characteristics: Test Object: jacket Test Test Test Test Material: Material: Material: Material: PVC Rated Temperature: 75 deg. Before Tensile Strength (Mpa): >=1.034 Product standard certificate: UL Aging Elongation (%): >=200 Flammability test: CM, CMG Aging Aging Aging Aging condition condition condition condition (deg./hrs): (deg./hrs): (deg./hrs): (deg./hrs): 113 +/-1.0, 168 After Tensile Strength (Mpa): >=85% unaged Aging Elongation (%): >=50% unaged Cold Bend (-20+/-2 deg._4h): no crack Jacket impact test (-15deg.): no crack Jacket longitudinal shrinkage (%) <=5 Center conductor bond to dielectric (N): >=2.3

Transcript of Coaxial Cable

Coaxial CableRG59 DC

Cross Sectioncenter condcutor

insulation

braiding

jacket

Construction PerformanceCenterCenterCenterCenter conductor:conductor:conductor:conductor: Bare copper Electrical Characteristics:AWG: 20 Fequency AttenuationDia.: 0.813mm (MHz) (db/100m)

1 0.79Insulation:Insulation:Insulation:Insulation: Foam PE with skin 10 2.5Norm. thickness: 1.78mm 100 9.05insulation Dia.: 3.66 +/- 0.08mm 400 19.76

BraidingBraidingBraidingBraiding Shield:Shield:Shield:Shield: bare copper wire Dielectric strength (kv/min) 1.0 Construction: 16*7/0.16mm Impedence (ohms) 75+/-3Coverage: >= 95% Capacitance (PF/m) 53.1

Cond. DCR at 20 deg. (ohms/km)<=33.9Jacket:Jacket:Jacket:Jacket: PVC Velocity of propagation (%) >=82Norm. thickness: 0.80mmMin. thickness: 0.70mmOut Dia. 6.0 +/- 0.1mm Mechanical Characteristics:

Test Object: jacket

TestTestTestTest Material:Material:Material:Material: PVC

Rated Temperature: 75 deg. Before Tensile Strength (Mpa): >=1.034

Product standard certificate: UL Aging Elongation (%): >=200

Flammability test: CM, CMG AgingAgingAgingAging conditionconditionconditioncondition (deg./hrs):(deg./hrs):(deg./hrs):(deg./hrs): 113 +/-1.0, 168

After Tensile Strength (Mpa): >=85% unaged

Aging Elongation (%): >=50% unaged

Cold Bend (-20+/-2 deg._4h): no crack

Jacket impact test (-15deg.): no crack

Jacket longitudinal shrinkage (%):<=5

Center conductor bond to dielectric (N): >=2.3