CO2 Level

download CO2 Level

of 2

Transcript of CO2 Level

  • 7/22/2019 CO2 Level

    1/2

    Guided Wave Radar Level Measurement in

    CO2storage tanks

    Levelflex M, Ideal choice for liquid CO2storage tanks.

    Brewing or Soft drink production Levelflex M - FMP40 Carbonated beverages

    The guided wave radar Levelflex M -FMP40 is used to measure the level in

    bullet shaped CO2storage tanks

    Customer Profile

    Application common to Breweries andcarbonated soft drinks where CO2is stored

    Value Proposition

    QualityRevenue

    CostEfficiency

    RiskSoft Facts

    Reliable measurement was needed both forcontrol and inventory purpose. Product loss

    of beer would result if control is notaccurate. The FMP 40 provided an effective

    measurement with low unit and installationcost.

    Application description

    Products: Liquid CO2

    Tanks: Bullet shaped horizontal tank

    Temp: Ambient

    Pressure: 250-300psiRadar: FMP40 coax or cable version

    Mounting: from top of tank

    Application

    The customer had 6 x 6500 gallon CO2tanks, 4 located outdoors and 2 indoors

    working as buffers for production. Thecustomer was relying on sight glass to

    determine level but this was very unreliableand often resulted in lack of CO2or over fills.

    The customer had tried other guided radarbut with poor results. They also wanted to

    use existing nozzles on top of tank.

    CO2has very low dielectric constant so forthe first tank a Coax version rod probe was

    used to optimize the measurement. Howeverfor the second tank there was not enoughroom above the tank to allow for installation

    of the rod. A cable version was thereforeused.

    Measurement results

    The coax version worked perfect without

    any special settings. The cable probe actederratic until the patented end-of probe

    function was adjusted. A single rod or cableprobe would not work without the end of

    probe function due to the low dielectric ofthe CO2. They have been operational for

    over 3 months and the customer is verysatisfied with the measurement performance.

    Instrument description

    The Levelflex M is a top-mounted, compactlevel transmitter that operates with micro-

    impulse radar on the guided time-of-flightprinciple. Fluctuations in the density,

    temperature, or build-up do not influencethe measurement.

    Measuring principle

    The Levelflex is a downward-lookingTime-of-Flight (ToF) measuring system

    which measures the distance from theprocess connection to the material surface.

    An electrical pulse is launched and guideddown the probe. The pulses are reflected by

    the product surface, received by theelectronics, evaluated and converted into

    level information.

  • 7/22/2019 CO2 Level

    2/2

    USA Canada Mexico

    Endress+Hauser, Inc.

    2350 Endress Place

    Greenwood, IN 46143Tel. 317-535-7138

    Sales 888-ENDRESS

    Service 800-642-8737Fax [email protected]

    www.us.endress.com

    Endress+Hauser Canada1075 Sutton DriveBurlington, ON L7L 5Z8

    Tel. 905-681-9292800-668-3199Fax 905-681-9444

    www.ca.endress.com

    Endress+HauserPaseo del Pedregal No. 610Col. Jardines del Pedregal

    01900, Mexico D.F.MEXICOTel. 525-568-2405Fax 525-568-7459

    CS 0262/24/ae/06.05AE/doc

    FMP40 Cable Version

    FMP40 Coax Version

    Installation of Guided

    Wave Radar - LevelflexFMP 40 in CO2tanks

    Envelope Curve captured with the free ToF-Tool software. The patented End of Probe algorithm used in

    Levelflex M instrument makes it possible to use guided radar in application with very low dielectric constant.