CloudEngine 6800&5800 V100R001C00 Routine Maintenance 01.pdf

download CloudEngine 6800&5800 V100R001C00 Routine Maintenance 01.pdf

of 13

Transcript of CloudEngine 6800&5800 V100R001C00 Routine Maintenance 01.pdf

  • CloudEngine 6800&5800 Series Switches

    Routine Maintenance

    Issue 01Date 2013-05-10

    HUAWEI TECHNOLOGIES CO., LTD.

  • Copyright Huawei Technologies Co., Ltd. 2013. All rights reserved.No part of this document may be reproduced or transmitted in any form or by any means without prior writtenconsent of Huawei Technologies Co., Ltd. Trademarks and Permissions

    and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.All other trademarks and trade names mentioned in this document are the property of their respective holders. NoticeThe purchased products, services and features are stipulated by the contract made between Huawei and thecustomer. All or part of the products, services and features described in this document may not be within thepurchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,and recommendations in this document are provided "AS IS" without warranties, guarantees or representationsof any kind, either express or implied.

    The information in this document is subject to change without notice. Every effort has been made in thepreparation of this document to ensure accuracy of the contents, but all statements, information, andrecommendations in this document do not constitute a warranty of any kind, express or implied. Huawei Technologies Co., Ltd.Address: Huawei Industrial Base

    Bantian, LonggangShenzhen 518129People's Republic of China

    Website: http://enterprise.huawei.com

    Issue 01 (2013-05-10) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    i

  • About This Document

    Intended AudienceThis document describes the maintenance operations for CloudEngine 6800&5800.This document is intended for:l Network monitoring engineersl On-site maintenance engineersl System maintenance engineers

    Symbol ConventionsThe symbols that may be found in this document are defined as follows.

    Symbol Description

    DANGERIndicates a hazard with a high level or medium level of riskwhich, if not avoided, could result in death or serious injury.

    WARNINGIndicates a hazard with a low level of risk which, if notavoided, could result in minor or moderate injury.

    CAUTIONIndicates a potentially hazardous situation that, if notavoided, could result in equipment damage, data loss,performance deterioration, or unanticipated results.

    TIP Provides a tip that may help you solve a problem or save time.

    NOTE Provides additional information to emphasize or supplementimportant points in the main text.

    Command ConventionsThe command conventions that may be found in this document are defined as follows.

    CloudEngine 6800&5800 Series SwitchesRoutine Maintenance About This Document

    Issue 01 (2013-05-10) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    ii

  • Convention DescriptionBoldface The keywords of a command line are in boldface.Italic Command arguments are in italics.[ ] Items (keywords or arguments) in brackets [ ] are optional.{ x | y | ... } Optional items are grouped in braces and separated by

    vertical bars. One item is selected.[ x | y | ... ] Optional items are grouped in brackets and separated by

    vertical bars. One item is selected or no item is selected.{ x | y | ... }* Optional items are grouped in braces and separated by

    vertical bars. A minimum of one item or a maximum of allitems can be selected.

    [ x | y | ... ]* Optional items are grouped in brackets and separated byvertical bars. You can select one or several items, or selectno item.

    & The parameter before the & sign can be repeated 1 to n times.# A line starting with the # sign is comments.

    Change HistoryUpdates between document issues are cumulative. Therefore, the latest document issue containsall updates made in previous issues.

    Changes in Issue 01 (2013-05-10)Initial commercial release.

    CloudEngine 6800&5800 Series SwitchesRoutine Maintenance About This Document

    Issue 01 (2013-05-10) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    iii

  • Contents

    About This Document.....................................................................................................................ii1 Introduction to the Routine Maintenance................................................................................12 Checking the Running Environment.........................................................................................23 Checking Basic Device Information..........................................................................................54 Checking the Device Running Status........................................................................................75 Checking the Interface Information..........................................................................................8

    CloudEngine 6800&5800 Series SwitchesRoutine Maintenance Contents

    Issue 01 (2013-05-10) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    iv

  • 1 Introduction to the Routine MaintenanceThe stable running of switches depends on the proper network planning and routine maintenanceand monitoring on the switches. It is necessary to find hidden hazards during routine maintenanceand monitoring. The inspection checklist provides the routine maintenance recommendation forthe switches.

    CloudEngine 6800&5800 Series SwitchesRoutine Maintenance 1 Introduction to the Routine Maintenance

    Issue 01 (2013-05-10) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    1

  • 2 Checking the Running EnvironmentDevices can run properly only after the following conditions are met.

    No. Check Item Criteria Result1 Position of the device The device should be

    placed steadily in aflat position in aventilated and dryenvironment.

    Satisfied Unsatisfied Not involved

    2 Ambient temperature inthe equipment room

    l Operatingtemperature: 0Cto 40C (0 m to1800 m)NOTE

    When the altitudeis between 1800 mand 5000 m, theoperatingtemperaturereduces 1C everytime the altitudeincreases 220 m.

    l Storagetemperature: -40C to +70C

    Satisfied Unsatisfied Not involved

    3 Ambient humidity Operating relativehumidity: 5% RH to95% RH(noncondensing)

    Satisfied Unsatisfied Not involved

    4 Air conditioner in theequipment room

    The air conditionerkeeps running steadilyso that thetemperature in theequipment room iswithin an acceptablerange.

    Satisfied Unsatisfied Not involved

    CloudEngine 6800&5800 Series SwitchesRoutine Maintenance 2 Checking the Running Environment

    Issue 01 (2013-05-10) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    2

  • No. Check Item Criteria Result5 Grounding and grounding

    resistanceWorking grounding,protection grounding,and surge protectiongrounding should bearranged separately inthe equipment room.Joint grounding canbe used if theequipment room isunder limitedconditions.Grounding issignificant especiallyfor outdoor devicesbecause the outdoordevices are possiblystruck by thunder.

    Satisfied Unsatisfied Not involved

    6 Connection to powersupply

    Power cables shouldbe correctly andfixedly connected tothe specified positionof the device. Thepower supplyindicator on thedevice should besteady green.

    Satisfied Unsatisfied Not involved

    7 Power supply system The power supplysystem should runstably.l Rated voltage: 100

    V AC to 240 VAC, 50/60 Hz

    l Maximum voltagerange: 90 V AC to290 V AC, 45 Hzto 65 Hz

    Satisfied Unsatisfied Not involved

    8 Ventilation channel No sundries existaround the device.There is at least 1 Uclearance betweentwo devices to ensureefficient heatdissipation.

    Satisfied Unsatisfied Not involved

    CloudEngine 6800&5800 Series SwitchesRoutine Maintenance 2 Checking the Running Environment

    Issue 01 (2013-05-10) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    3

  • No. Check Item Criteria Result9 Heat dissipation Power modules and

    fan modules in achassis have the sameairflow direction. Thedevice has the sameairflow direction asthat of other devices inthe same cabinet.

    Satisfied Unsatisfied Not involved

    10 Fan module The fan moduleindicator on thedevice should slowlyblink green.

    Satisfied Unsatisfied Not involved

    11 Device operation The SYS indicator onthe device shouldslowly blink green.

    Satisfied Unsatisfied Not involved

    CloudEngine 6800&5800 Series SwitchesRoutine Maintenance 2 Checking the Running Environment

    Issue 01 (2013-05-10) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    4

  • 3 Checking Basic Device InformationThe basic device information includes software version, patch information, and system time.

    No. Check Item Command Criteria Result1 Software

    versionRun the displayversion command.

    The PCB versionsand softwareversion are correct.

    Satisfied Unsatisfied Not involved

    2 Softwarepackage

    Run the displaystartup command.

    The names of thesoftware andconfiguration filethat are in use andthat will be loadedat next startup arecorrect.

    Satisfied Unsatisfied Not involved

    3 Patchinformation

    Run the displaypatch-informationcommand.

    The installedpatches meet therequirements. Thelatest patch of theproduct isrecommended.

    Satisfied Unsatisfied Not involved

    CloudEngine 6800&5800 Series SwitchesRoutine Maintenance 3 Checking Basic Device Information

    Issue 01 (2013-05-10) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    5

  • No. Check Item Command Criteria Result4 System time Run the display

    clock command.l The system

    time is thesame as thelocal time (timedifference iswithin 5minutes). Thecorrect systemtime makesfault locatingaccurate.

    l If the systemtime isincorrect, runthe clockdatetimecommand tochange thesystem time orrun NTP.

    Satisfied Unsatisfied Not involved

    5 Configurations Run the displaycurrent-configurationcommand.

    The currentparameter settingson the switch arecorrect.

    Satisfied Unsatisfied Not involved

    CloudEngine 6800&5800 Series SwitchesRoutine Maintenance 3 Checking Basic Device Information

    Issue 01 (2013-05-10) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    6

  • 4 Checking the Device Running StatusThe running status of a switch includes the running status of subcards, resetting information,and device temperature.

    No. Check Item Method Criteria Result1 Fan status Run the display

    device fancommand.

    The Status fielddisplays Normal.

    Satisfied Unsatisfied Not involved

    2 Power supplystatus

    Run the displaydevice powercommand.

    The State fielddisplays Supply.

    Satisfied Unsatisfied Not involved

    3 Devicetemperature

    Run the displaydevicetemperaturecommand.

    The Status fielddisplays Normal.

    Satisfied Unsatisfied Not involved

    4 CPU usage Run the displaycpu command.

    CPU usage of thedevice is withinthe allowed range.

    Satisfied Unsatisfied Not involved

    5 Memory usage Run the displaymemorycommand.

    Memory usage ofthe device iswithin the allowedrange.

    Satisfied Unsatisfied Not involved

    CloudEngine 6800&5800 Series SwitchesRoutine Maintenance 4 Checking the Device Running Status

    Issue 01 (2013-05-10) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    7

  • 5 Checking the Interface InformationThe interface information includes the negotiation mode, configurations, and status of theinterface.

    No. Check Item Command Criteria Result1 Errored packet Run the display

    interfacecommand.

    No erroredpackets, includingthe CRC erroredpackets, exist onthe interfaceduring servicerunning.

    Satisfied Unsatisfied Not involved

    2 Negotiationmode

    Run the displayinterfacecommand.

    The negotiationmode of theinterface is correct.The negotiationmodes of the twoconnectedinterfaces must bethe same. Nointerface is in half-duplex mode.

    Satisfied Unsatisfied Not involved

    3 Interface status Run the displayinterface briefcommand.

    The Up/Downstatus of theinterface meets therequirements.

    Satisfied Unsatisfied Not involved

    CloudEngine 6800&5800 Series SwitchesRoutine Maintenance 5 Checking the Interface Information

    Issue 01 (2013-05-10) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    8

    About This DocumentContents1 Introduction to the Routine Maintenance2 Checking the Running Environment3 Checking Basic Device Information4 Checking the Device Running Status5 Checking the Interface Information