    Measure the distance between the front and rear mounting rails (distance A in the figure below), and select appropriate mounting brackets and guide rails according to this distance. (See the following figures.)

    The CE6800&5800 series switches are 1 U high (1 U = 44.45 mm), and their width is standard.The CE6800&5800 series switches must be installed in a standard 19-inch four-post cabinet or rack. The cabinet for a CE5800 switch must be at least 600 mm deep, and the cabinet for a CE6800 switch must be at least 800 mm deep.To reserve sufficient space for cabling, ensure that the distance from the mounting rails at the switch's port side to the cabinet door is no less than 130 mm. The cabinet must have a reliable ground point to ground the switch.If the CE6800&5800 series switches are installed in the same cabinet with a CE12800 switch, keep a distance of 700 mm to 800 mm between the front and rear mounting rails.

    Secure mounting brackets to the chassis with M4 screws.

    Connect the ground cable to the chassis ground point and coil the other end on top of the chassis.

    Mountingbrackets andguide rails

    Front-to-back airflow (fan tray panel to interior): Air flows from the power supply side to the port side. A power module or fan module with front-to-back airflow is identified by the flag on the right.

    Back-to-front airflow (interior to fan tray panel): Air flows from the port side to the power supply side. A power module or fan module with back-to-front airflow is identified by the flag on the right.

    1

    2

    3

    4

    5

    6

    7

    8

    Item Connect To Remarks

    External power source

    Upstream network device or stacked switch

    AC power cable

    DC power cable

    Optical fiber

    The length of three adjacent mounting holes may not be 1 U. Observe the scale ticks on the mounting rails when installing floating nuts.

    Category 5 or higher category network cables are recommended for GE electrical ports.Category 6A shielded or higher category network cables are recommended for 10GE electrical ports.

    10GE optical ports use SFP/SFP+ optical modules and optical fibers or SFP+ copper cables.40GE optical modules use QSFP+ optical modules and optical fiber or QSFP+ copper cables.Copper cable

    The switch must use the power modules and fan modules matching the product model.Power modules with different airflow directions or power values, AC and DC power modules, or fan modules with different airflow directions cannot be used in the same chassis.

    To ensure normal operating, the switch must have two normally running fan modules. Replace a fan module within 3 minutes.If only one power module is used, install a filler panel in the other power module slot.

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 3 4 1 2SYSMSTSTATSPEEDSTACK

    MODE/IDCE5850-48T4S2Q-EI

    31 4

    6

    5 8

    PAC-150WA ~100-240V;50/60Hz,2.5A

    STATUS

    PAC-150WA ~100-240V;50/60Hz,2.5A

    STATUSCONSOLE

    ETH

    SYS

    MST

    ACT

    L/A

    ID

    PWR1 FAN1 FAN2 PWR2

    CE5850-48T4S2Q-EISTATUS

    FAN-40EA-F

    STATUS

    FAN-40EA-F

    Managementnetwork

    Install eight floating nuts on the front and rear mounting rails, two on each mounting rail. Leave a distance of 1 U between the two floating nuts on each mounting rail.

    Secure guide rails on the front mounting rails with M6 screws.Hold bottom of the chassis, align the mounting brackets with the guide rails, and slowly slide the chassis into the cabinet.

    Insert the power module into a power module slot.

    Tighten the captive screws on the power module panel.

    Secure the chassis onto the cabinet with M6 screws.Then, connect the ground cable to the ground point on the cabinet.

    2 7

    Ground cableM6 lug: to the protection ground

    Network cable

    Network cable

    Switch or computer

    Operation terminal (usually a PC)

    Operation terminal (usually a PC)

    The ETH management port connects to an operation terminal or network management workstation for local or remote configuration of the switch. This port must use a Category 5 or higher category network cable.

    When the switch is powered on for the first time, use this port for onsite configuration.Console cable

    USB port USB flash drive This port is used to transfer upgrade files and configuration files during a USB-based deployment.

    Quick Start GuideCloudEngine 6800&5800 Series Switches

    Packing List

    Safety Guidelines

    Take ESD protection measures during equipment installation and maintenance. For example, wear ESD gloves or an ESD wrist strap.During equipment transport and installation, prevent the equipment from colliding with objects like doors, walls, or shelves. Do not touch unpainted surfaces of the equipment with wet or contaminated gloves.Do not place other objects on the chassis.

    The installation, cable connection, and login methods for the CE6800&5800 series switches are similar. This document uses CE5850-48T4S2Q-EI as an example. For more information, see the Hardware Installation and Maintenance Guide. Figures in the document are for reference only and may be different from actual devices.

    Site EnvironmentDo not place or operate the switch in an environment with flammable or explosive gases or smoke.The switch must be installed in a clean, dry, well ventilated site with stable temperature. The installation site must be free from leaking or dripping water, heavy dew, and humidity.The installation site must be well ventilated, and air vents of the switch must not be blocked.It is recommended to leave sufficient clearance around the switch for heat dissipation.The temperature and humidity in the installation site must be within the normal ranges. (Operating temperature: 0C to 40C at an altitude of 0 m to 1800 m; when the altitude is between 1800 m and 5000 m, the maximum operating temperature decreases by 1C every time the altitude increases by 220 m. Operating humidity: 5%RH to 95%RH, noncondensing).

    4.1 Requirements for the Cabinet

    5.1 Selecting Power Modules and Fan Modules

    5.2 Installing Power Modules and Fan Modules into the Chassis

    4.2 Installing the Chassis in a CabinetMounting brackets and guide rails for the CE6800&5800 series switches

    Install the chassis in the cabinet

    SupportedSupported

    SupportedSupported

    SupportedNot supported

    SupportedNot supported

    SupportedSupported

    Enterprise networking community: http://support.huawei.com/ecommunity

    You can obtain the latest product documentation at http://support.huawei.com/enterprise. Log in to the website, and select a specific product model and version to download its documentation.If the instructions contained in the product documentation are insufficient to resolve problems that occur during device operation or maintenance, contact Huawei Technical Assistance Center for technical support.

    Obtaining Product Documentation and Technical Support

    Logging In to the Switch1

    2

    3

    Use a console cable to connect a PC to the console port of the switch.

    Please configure the login password (8-16)Enter Password: Confirm Password:

    Start the terminal simulation software, create a connection, select a serial port, and set communication parameters as follows:Bits per second (B): 9600Data bits (B): 8Parity (P): NoneStop bits (S): 1Flow control (F): None

    After successful login, you can configure the switch on the command line interface. For more information, see the Configuration Guide.

    If your PC's operating system provides terminal simulation software (like HyperTerminal in Windows 2000/XP), you do not need to install additional terminal simulation software. If the PC runs on an operating system without terminal simulation software (like Windows 7), install third-party terminal simulation software on the PC by referring to user manual or online help.

    A PC may have more than one serial port. Select the port connected to the console port. Generally, COM1 is used.

    If password authentication is not configured, you do not need to enter a password, but this brings security risks. Password authentication is recommended.The password is a string of 8 to 16 case-sensitive characters. It must contain at least two types of the following characters: uppercase letters, lowercase letters, digits 0 to 9, and special characters excluding question mark (?) and spaces.The password entered in interactive mode is not displayed on the screen.After a login password is configured, this password will be required upon next login if password authentication is used on this user interface. If you forget the login password, see the Troubleshooting to restore the password.

    Connecting Cables

    The ground cable must be reliably grounded. If a cabinet or rack has anti-rust coating, scrape off the paint around the ground point to ensure reliable grounding.

    To protect the switch from lightning, route outdoor cables underground or in steel pipes. Do not route cables aerially.

    Connectors of fibers and cable must be clean. If a fiber connector is contaminated, clean it with an alcohol swap. The bend radius of optical fibers must be larger than 40 mm.

    Secure the AC power cable on the AC power module with the locking latch.The AC power outlet connected to the power module must allow a minimum of 10 A current. For a country-specific standard outlet, use an AC power cable complying with the local. For a C13 straight power outlet, use an AC power cable with a C13 straight female connector and a C14 straight male connector.

    Connect the positive cable to the positive pole on the DC power module and the negative cable to the negative pole.On the DC power cable plug, the red end is RTN (+), and the blue end is NEG (-). You can also identify the positive and negative poles by the silkscreens on the plug.

    Do not install power cables while the power is on. Do not turn on the power until you have finished installing the chassis and connecting cables.Do not look into bores of optical modules or optical fibers without eye protection. Laser beams will cause eye damage.

    Installing other Modules

    PAC-150WA

    STATUS

    2

    1

    1

    2

    Power modules and fan modules are hot swappable, and they are installed in the same way. A power module is used as an example here.Before installing a power module or fan module, remove the filler panel in the slot.Connect positive and negative power cables to positive and negative poles on a DC power module correctly.

    1

    2

    3

    4

    5

    Distance A

    Distance A

    Determine the directions of the port side and power supply side according to actual situations in your equipment room. In a typical data center scenario, if the switch needs to connect to servers in the same cabinet, make its port side face rear of the cabinet to facilitate cable connections with the servers. Whether the mounting brackets and guide rails should be installed near the port side or power supply side depends on the direction in which the chassis is installed. Ensure that the rear mounting brackets will not touch the cabinet door. The figures here are for reference only.

    Mounting bracket A

    Mounting bracket and guide rail bundles for the CE5800

    Mounting bracket and guide rail bundles for the CE6800

    308 mm-351 mm

    436 mm-479 mm

    539 mm-638 mm

    367 mm-410 mm

    495 mm-538 mm

    697 mm-839 mm639 mm-696 mm

    547 mm-551 mm493 mm-546 mm

    681 mm-818 mm552 mm-680 mm

    Mounting bracket A +mounting bracket B + guide rail A

    Mounting bracket A +mounting bracket B + guide rail A

    Mounting bracket A +mounting bracket B + guide rail A

    Mounting bracket A +mounting bracket C + guide rail A

    Mounting bracket A +mounting bracket B + guide rail A

    Mounting bracket A +mounting bracket C + guide rail B

    Mounting bracket A +mounting bracket C + guide rail A

    Mounting bracket A +mounting bracket C + guide rail A

    Mounting bracket A +mounting bracket C + guide rail A

    Mounting bracket A +mounting bracket C + guide rail A

    Mounting bracket A +mounting bracket C + guide rail A

    Mounting bracket B Mounting bracket C Guide rail A Guide rail B

    RTN(+)

    NEG(-)

    Front mounting rail Rear mounting rail

    4

    X81

    3

    2

    5

    21

    Installation accessory packageChassis ground cableConsole cable

    Warranty cardQuick Start Guide

    Mounting brackets and guide railFloating nuts

    M4 screwsM6 screws

    Chassis (with the product model on the nameplate) Installation accessories include:

    Observe all safety regulations and precautionsTo ensure personal and equipment safety, observe all the safety precautions on the equipment and in this document. and items do not cover all the safety precautions and are only supplementary to the safety precautions.Follow all the safety precautions and instructions provided by Huawei. The safety precautions outlined in this document are only those that Huawei can predict. Huawei is not liable for any consequence that results from violation of regulations pertaining to safe operations or safety codes pertaining to design, production, and equipment use.

    WARNING

    WARNING

    NOTICE

    WARNINGThis is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

    NOTICE

    NOTICE

    NOTICE

    NOTICE

    NOTICE

    NOTICE

    NOTICE

    NOTE

    NOTE

    NOTE

    NOTE

    NOTE

    NOTE

    Installing the Chassis

    No.

    Press Enter in the subsequent dialog boxes until the following information is displayed, and then enter a password. The configured password will be saved in the system.

    and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.All other trademarks and trade names mentioned in this document are the property of their respective holders.

    Copyright Huawei Technologies Co., Ltd. 2013. All rights reserved.No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.

    Trademarks and Permissions

    04(2013-11-30)Part number: 31505402

    Note: Install mounting bracket C in mounting holes at middle of the chassis.

    Note: Note: If the cabinet is 800 mm deep, mounting bracket C will touch the cabinet door. Do not close the door at this side.

    Note: Note: If the cabinet is 800 mm deep, mounting bracket C will touch the cabinet door. Do not close the door at this side.