CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014...

114
RP-QT-127B Rev.0 QUALITECH INSPECTION, REPAIR AND MAINTENACE LTD. GENERAL NDT INSPECTIONS CLIENT: TRANSOCEAN LOCATION: SEDCO 706 PO N°: 1334050 WO N°: 1053/1 Date: 12/08/2014 Version: Original Volume: 1 of 1

Transcript of CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014...

Page 1: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

RP-QT-127B Rev.0

QUALITECH INSPECTION, REPAIR AND MAINTENACE LTD.

GENERAL NDT INSPECTIONS

CLIENT: TRANSOCEAN

LOCATION: SEDCO 706

PO N°: 1334050 WO N°: 1053/1

Date: 12/08/2014 Version: Original Volume: 1 of 1

Page 2: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

RP-QT-127B Rev.0

CONTENT

SECTION 01 - EXECUTIVE SUMMARY REPORT

SECTION 02 – WORK BASKETS

SECTION 03 – STBD AND PORT BOP CRANE & HOOKS AFTER THE LOAD TEST

SECTION 04 – BOP PAD EYES LIFTING CONNECTOR

SECTION 05 – BOP LIFTING CONNECTOR PAD EYE

SECTION 06 – PEDESTAL PORT CRANE & ASSOCIATED EQUIPMENTS

SECTION 07 – STBD CRANE & ASSOCIATED EQUIPMENTS

SECTION 08 – MANUAL TONG AND PARTS

SECTION 09 – ROV SUPPORT BASE

SECTION 10 – FLEX JOINT ADAPTER

SECTION 11 – HP CEMENT LINE WELD

SECTION 12 – LIFEBOAT 1 AND 2 SUPPORT DAVIT

SECTION 13 – LIFEBOATS WEDGE SOCKETS

SECTION 14 – DRILL STRING COMPENSATOR

SECTION 15 – RBS CLEVIS POINT

SECTION 16 – FLARE BOOM BASE STRUCTURE

SECTION 17 – TECHINICIAN CERTIFICATE

SECTION 18 – COMPANY CERTIFICATE

Page 3: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 4: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 5: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 1 of 2

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-150 Rev. 1

CERTIFICATE OF THOROUGH EXAMINATION

Health and Safety, The Lifting Operations and Lifting Equipment Regulations 1998 Statutory Instruments 1998 No. 2307 Customer: Transocean Certificate Number: QT-1053-001 Location: Sedco 706 Date of Thorough Examination: 11/03/2014

Manufacturer: Safe Lift Offshore LTDA Equipment Status: New

Equipment: Basket Serial Number: SOL / 9816/1 Manufacture Date: N/A Tare: 200 Kg SWL:1.500 Kg

Area Inspected: As per clients request a 100% Visual Inspection was carried out on offshore container and lifting equipment’s fitted Following L.O.L.E.R. Procedures. Fitting Equipments: 1 Set of four leg wire rope sling SWL 4 Ton Te: SERIAL NUMBER: SOL / 9816/1A 1 Set of four Shackles Safety Pin Bow SWL 3.25 Ton Te: SERIAL NUMBER: 16/1B 16/1C 16/1D 16/1E Results: No defects or injurious were found on time of inspection. Recommendations: Acceptable to Specification.

Name / Qualification: Paulo Vitor Paraiba

ASNT / II

Signed / Stamp: Date of Inspection: 17/07/2014

Approved by:

Page 6: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 2 of 2

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-150 Rev. 1

CERTIFICATE OF THOROUGH EXAMINATION

Health and Safety, The Lifting Operations and Lifting Equipment Regulations 1998 Statutory Instruments 1998 No. 2307 Customer: Transocean Certificate Number: QT-1053-002 Location: Sedco 706 Date of Thorough Examination: 11/03/2014

Manufacturer: Safe Lift Offshore LTDA Equipment Status: New

Equipment: Basket Serial Number: SOL / 9816/2 Manufacture Date:N/A Tare: 200 Kg SWL: 1.500 Kg Area Inspected: As per clients request a 100% Visual Inspection was carried out on offshore container and lifting equipment’s fitted Following L.O.L.E.R. Procedures. Fitting Equipments: 1 Set of four leg wire rope sling SWL 4 Ton Te: SERIAL NUMBER: SOL / 9816/2A 1 Set of four Shackles Safety Pin Bow SWL 3.25 Ton Te: SERIAL NUMBER: 16/2B 16/2C 16/2D 16/2E Results: No defects or injurious were found on time of inspection. Recommendations: Acceptable to Specification.

Name / Qualification: Paulo Vitor Paraiba

ASNT II

Signed / Stamp: Date of Inspection: 17/07/2014

Approved by:

Page 7: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 1 of 14

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

EDDY CURRENT INSPECTION REPORT

Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure: PI-QT-06 Rev.0

Client PMS Number: N/A Surface: Painted

Probes Probes Serial No Frequency Gain Phase Calibration

PWM100S000 502016/01 100Khz 40 db 321 DEG 3 db for every 0.5mm PWM100S000 501943/01 100Khz 47 db 291 DEG 1mm Slot to SFH NOTE: Compensations made for variable geometry and paint thickness. Equipment Description: BOP Crane Stbd.

Serial Number: N/A Size: N/A

Manufacture: N/A Material: N/A Qty:01

Specification: BS EN 1711 Reference Drawing N°:N/A Comment: Area Inspected: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the all critical and accessible of the BOP Crane Stbd after Load Test. Result: No defects or indications were found at time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: yes

Name / Qualification: Rafael Cardoso/ ASNT II

ET-4331

Signed / Stamp:

Date of Inspection: 29/06/2014

Approved By:

Equipments

Page 8: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 2 of 14

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

EDDY CURRENT INSPECTION REPORT

Client: Transocean Report Number: QT-EC-1053-36 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: BOP Crane Stbd. Inspection Details: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the BOP Crane Stbd after load test.

Name / Qualification: Rafael Cardoso/ ASNT II

ET-4331

Signed / Stamp:

Date of Inspection: 29/06/2014

Approved By:

Inspected Areas

Page 9: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 3 of 14

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

EDDY CURRENT INSPECTION REPORT

Client: Transocean Report Number: QT-EC-1053-36 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: BOP Crane Stbd. Inspection Details: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the BOP Crane Stbd After Load Test.

Name / Qualification: Rafael Cardoso/ ASNT II

ET-4331

Signed / Stamp:

Date of Inspection: 29/06/2014

Approved By:

Inspected Areas

Page 10: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 4 of 14

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

EDDY CURRENT INSPECTION REPORT

Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-37 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure: PI-QT-06 Rev.0

Client PMS Number: Surface: Painted

Probes Probes Serial No Frequency Gain Phase Calibration

PWM100S000 502016/01 100Khz 40 db 321 DEG 3 db for every 0.5mm PWM100S000 501943/01 100Khz 47 db 291 DEG 1mm Slot to SFH NOTE: Compensations made for variable geometry and paint thickness. Equipment Description: BOP Crane Port.

Serial Number:N/A Size: N/A

Manufacture: N/A Material: N/A Qty:01

Specification: BS EN 1711 Reference Drawing N°:N/A Comment: Area Inspected: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the all critical and accessible of the BOP Crane Port after Load Test. Result: No defects or indications were found at time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: yes

Name / Qualification: Rafael Cardoso/ ASNT II

ET-4331

Signed / Stamp:

Date of Inspection: 29/06/2014

Approved By:

Equipments

Page 11: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 5 of 14

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

EDDY CURRENT INSPECTION REPORT

Client: Transocean Report Number: QT-EC-1053-37 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: BOP Crane Port. Inspection Details: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the BOP Crane Port after load test.

Name / Qualification: Rafael Cardoso/ ASNT II

ET-4331

Signed / Stamp:

Date of Inspection: 29/06/2014

Approved By:

Inspected Areas

Page 12: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 6 of 14

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

EDDY CURRENT INSPECTION REPORT

Client: Transocean Report Number: QT-EC-1053-37 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: BOP Crane Port after load test. Inspection Details: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the BOP Crane Port after load test.

Name / Qualification:

Rafael Cardoso/ ASNT II ET-4331

Signed / Stamp:

Date of Inspection: 29/06/2014

Approved By:

Inspected Areas

Page 13: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 7 of 14

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-050 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number:N/A Surface: Clean

Equipment Description: BOP Crane STBD plate and pin 80 Tons. Qty: 01 Size: 80 ton

Serial Number: 0757284 Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture:

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the BOP Crane STBD plate and pin 80 Tons. Result: No defects were found on time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification.

Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 29/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type: x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 14: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 8 of 14

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-050 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: BOP Crane STBD plate and pin 80 Tons.

Inspection Details: Magnetic Particle Inspection was carried out on the BOP Crane STBD plate and pin 80 Tons.No defects were found on time of inspection.

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 29/06/2014

Approved By:

Page 15: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 9 of 14

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-051 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number:N/A Surface: Clean

Equipment Description: BOP Crane PORT plate and pin 80 Tons. Qty: 01 Size: 80 ton

Serial Number: 0757283 Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture:

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the BOP Crane PORT plate and pin 80 Tons. Result: No defects were found on time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification.

Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 29/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type: x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 16: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 10 of 14

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-051 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: BOP Crane PORT plate and pin 80 Tons.

Inspection Details: Magnetic Particle Inspection was carried out on the BOP Crane PORT plate and pin 80 Tons.No defects were found on time of inspection.

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 29/06/2014

Approved By:

Page 17: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 11 of 14

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-052 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: BOP Crane STBD Hook. Qty: 01 Size: 15 ton

Serial Number: 0757283 Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture: N/A

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the BOP Crane STBD Hook. Result: No defects were found on time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification.

Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 29/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type: x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 18: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 12 of 14

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-052 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: BOP Crane STBD Hook.

Inspection Details: Magnetic Particle Inspection was carried out on the BOP Crane STBD Hook. No defects were found on time of inspection.

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 29/06/2014

Approved By:

Page 19: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 13 of 14

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-053 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: BOP Crane PORT Hook. Qty: 01 Size: 15 ton

Serial Number: 0757284 Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture:

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the BOP Crane PORT Hook. Result: No defects were found on time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification.

Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 29/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type: x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 20: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 14 of 14

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-053 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: BOP Crane PORT Hook.

Inspection Details: Magnetic Particle Inspection was carried out on BOP Crane PORT Hook. No defects were found on time of inspection.

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 29/06/2014

Approved By:

Page 21: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 1 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-046 P.O. Nr: N/A WO: QT-1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Pad eyes BOP Lifting Connector Qty: 04 Size: 6 Ton

Serial Number:N/A Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture:

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Pad eyes BOP Lifting Connector. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use.

Continuation Attached: Yes

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II MT-2444

Signed / Stamp:

Date of Inspection: 21/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 22: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 2 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-046 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Pad eyes BOP Lifting Connector

Inspection Details: Magnetic Particle Inspection was carried out on Pad eyes BOP Lifting Connector. No defects were found on time of inspection.

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II MT-2444

Signed / Stamp:

Date of Inspection: 21/06/2014

Approved By:

Page 23: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 3 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-047 P.O. Nr: N/A WO: QT-1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Pad eyes BOP Lifting Connector Qty: 04 Size: 6 Ton

Serial Number: N/A Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture:

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Padeyes BOP Lifting Connector Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use.

Continuation Attached: Yes

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II MT-2444

Signed / Stamp:

Date of Inspection: 21/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 24: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 4 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-047 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Pad eyes BOP Lifting Connector

Inspection Details: Magnetic Particle Inspection was carried out on the Pad eyes BOP Lifting Connector. No defects were found on time of inspection.

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II MT-2444

Signed / Stamp:

Date of Inspection: 21/06/2014

Approved By:

Page 25: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 1 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-046 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Padeyes BOP Lifting Connector Qty: 04 Size: 6 Ton

Serial Number:N/A Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture:

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Pad eyes BOP Lifting Connector. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use.

Continuation Attached: Yes

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II MT-2444

Signed / Stamp:

Date of Inspection: 21/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 26: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 2 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-046 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Padeyes BOP Lifting Connector

nspection Details: Magnetic Particle Inspection was carried out on Pad eyes BOP Lifting Connector. No defects were found on time of inspection.

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II MT-2444

Signed / Stamp:

Date of Inspection: 21/06/2014

Approved By:

Page 27: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 3 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-047 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Pad eyes BOP Lifting Connector Qty: 04 Size: 6 Ton

Serial Number:N/A Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture:

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Pad eyes BOP Lifting Connector Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use.

Continuation Attached: Yes

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II MT-2444

Signed / Stamp:

Date of Inspection: 21/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 28: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 4 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-047 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Padeyes BOP Lifting Connector

Inspection Details: Magnetic Particle Inspection was carried out on the Pad eyes BOP Lifting Connector. No defects were found on time of inspection.

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II MT-2444

Signed / Stamp:

Date of Inspection: 21/06/2014

Approved By:

Page 29: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 1 of 15

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

EDDY CURRENT INSPECTION REPORT

Client: Transocean Date: 07/07/2014 WO:1053 Report Number: QT-EC-1053-38 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure: PI-QT-06 Rev.0

Client PMS Number: Surface: Painted

Probes Probes Serial No Frequency Gain Phase Calibration

PWM100S000 502016/01 100Khz 40 db 321 DEG 3 db for every 0.5mm PWM100S000 501943/01 100Khz 47 db 291 DEG 1mm Slot to SFH NOTE: Compensations made for variable geometry and paint thickness. Equipment Description: Port Crane Pedestal.

Serial Number: N/A Size: N/A

Manufacture: Seatrax Material: Carbon Steel Qty:06

Specification: BS EN 1711 Reference Drawing N°:N/A Comment: Area Inspected: As per clients request a 10% Visual and Eddy Current Inspection was carried out on the all critical and accessible of the Port Crane Pedestal. Result: No defects or indications were found at time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: yes

Name / Qualification: Rafael Cardoso/ ASNT II

ET-4331

Signed / Stamp:

Date of Inspection: 07/07/2014

Approved By:

Equipments

Page 30: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 2 of 15

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

EDDY CURRENT INSPECTION REPORT

Client: Transocean Report Number: QT-EC-1053-38 P.O. Nr: N/A WO:1053 Location: Sedco 706

Item: Port Crane Pedestal. Inspection Details: As per clients request a 10% Visual and Eddy Current Inspection was carried out on the Port Crane Pedestal.

Name / Qualification:

Rafael Cardoso/ ASNT II ET-4331

Signed / Stamp:

Date of Inspection: 07/07/2014

Approved By:

Inspected Areas

Page 31: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 3 of 15

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

EDDY CURRENT INSPECTION REPORT

Client: Transocean Report Number: QT-EC-1053-38 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Port Crane Pedestal. Inspection Details: As per clients request a 10% Visual and Eddy Current Inspection was carried out on the Port Crane Pedestal.

Name / Qualification: Rafael Cardoso/ ASNT II

ET-4331

Signed / Stamp:

Date of Inspection: 07/07/2014

Approved By:

Inspected Areas

Page 32: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 4 of 15

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

EDDY CURRENT INSPECTION REPORT

Client: Transocean Date: 07/07/2014 WO:1053 Report Number: QT-EC-1053-39 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure: PI-QT-06 Rev.0

Client PMS Number: Surface: Painted

Probes Probes Serial No Frequency Gain Phase Calibration

PWM100S000 502016/01 100Khz 40 db 321 DEG 3 db for every 0.5mm PWM100S000 501943/01 100Khz 47 db 291 DEG 1mm Slot to SFH NOTE: Compensations made for variable geometry and paint thickness. Equipment Description: Port Crane A-Frame

Serial Number: N/A Size: N/A

Manufacture: Seatrax Material: Carbon Steel Qty:01

Specification: BS EN 1711 Reference Drawing N°:N/A Comment: Area Inspected: As per clients request a 10% Visual and Eddy Current Inspection was carried out on the all critical and accessible of the Port Crane A-Frame. Result: No defects or indications were found at time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: yes

Name / Qualification: Rafael Cardoso/ ASNT II

ET-4331

Signed / Stamp:

Date of Inspection: 07/07/2014

Approved By:

Equipments

Page 33: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 5 of 15

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

EDDY CURRENT INSPECTION REPORT

Client: Transocean Report Number: QT-EC-1053-39 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Port Crane A-Frame. Inspection Details: As per clients request a 10% Visual and Eddy Current Inspection was carried out on the Port Crane A-Frame.

Name / Qualification: Rafael Cardoso/ ASNT II

ET-4331

Signed / Stamp:

Date of Inspection: 07/07/2014

Approved By:

Inspected Areas

Page 34: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 6 of 15

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

EDDY CURRENT INSPECTION REPORT

Client: Transocean Report Number: QT-EC-1053-39 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Port Crane A-Frame. Inspection Details: As per clients request a 10% Visual and Eddy Current Inspection was carried out on the Port Crane A-Frame.

Name / Qualification: Rafael Cardoso/ ASNT II

ET-4331

Signed / Stamp:

Date of Inspection: 07/07/2014

Approved By:

Inspected Areas

Page 35: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 7 of 15

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

EDDY CURRENT INSPECTION REPORT

Client: Transocean Date: 07/07/2014 WO:1053 Report Number: QT-EC-1053-40 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure: PI-QT-06 Rev.0

Client PMS Number: Surface: Painted

Probes Probes Serial No Frequency Gain Phase Calibration

PWM100S000 502016/01 100Khz 40 db 321 DEG 3 db for every 0.5mm PWM100S000 501943/01 100Khz 47 db 291 DEG 1mm Slot to SFH NOTE: Compensations made for variable geometry and paint thickness. Equipment Description: Port Crane Boom.

Serial Number: N/A Size: N/A

Manufacture: Seatrax Material: Carbon Steel Qty:01

Specification: BS EN 1711 Reference Drawing N°:N/A Comment: Area Inspected: As per clients request a 10% Visual and Eddy Current Inspection was carried out on the all critical and accessible of the Port Crane Boom. Result: No defects or indications were found at time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: yes

Name / Qualification: Rafael Cardoso/ ASNT II

ET-4331

Signed / Stamp:

Date of Inspection: 07/07/2014

Approved By:

Equipments

Page 36: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 8 of 15

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

EDDY CURRENT INSPECTION REPORT

Client: Transocean Report Number: QT-EC-1053-40 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Port Crane Boom. Inspection Details: As per clients request a 10% Visual and Eddy Current Inspection was carried out on the Port Crane Boom.

Name / Qualification: Rafael Cardoso/ ASNT II

ET-4331

Signed / Stamp:

Date of Inspection: 07/07/2014

Approved By:

Inspected Areas

Page 37: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 9 of 15

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-55 P.O. Nr: N/A WO: QT-1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Port Crane Pedestal. Qty: 01 Size: N/A

Serial Number: N/A Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture: N/A

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Port Crane Pedestal. Result: No defects were found on time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 07/07/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 38: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 10 of 15

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-55 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Port Crane Pedestal.

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Port Crane Pedestal.. No defects were found on time of inspection.

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 07/07/2014

Approved By:

Page 39: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 11 of 15

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-55 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Port Crane Pedestal.

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Port Crane Pedestal.. No defects were found on time of inspection.

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 07/07/2014

Approved By:

Page 40: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 12 of 15

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-56 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number:N/A Surface: Clean

Equipment Description: Port Crane Main Hook . Qty: 01 Size: 49.1 ton

Serial Number: N/A Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture: Seatrax

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Port Crane Main Hook . Result: No defects were found on time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 07/07/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 41: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 13 of 15

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-56 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Port Crane Main Hook.

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Port Crane Main Hook. No defects were found on time of inspection.

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 07/07/2014

Approved By:

Page 42: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 14 of 15

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-57 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Port Crane Auxiliary Hook . Qty: 01 Size: 49.1 ton

Serial Number: N/A Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture: Seatrax

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Port Crane Auxiliary Hook . Result: No defects were found on time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 07/07/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type: x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 43: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 15 of 15

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-57 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Port Crane Auxiliary Hook .

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Port Crane Auxiliary Hook . No defects were found on time of inspection.

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 07/07/2014

Approved By:

Page 44: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 1 of 5

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

EDDY CURRENT INSPECTION REPORT

Client: Transocean Date: 04/07/2014 WO:1053 Report Number: QT-EC-1053-37 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure: PI-QT-06 Rev.0

Client PMS Number: N/A Surface: Painted

Probes Probes Serial No Frequency Gain Phase Calibration

PWM100S000 502016/01 100Khz 40 db 321 DEG 3 db for every 0.5mm PWM100S000 501943/01 100Khz 47 db 291 DEG 1mm Slot to SFH NOTE: Compensations made for variable geometry and paint thickness. Equipment Description: Stbd Crane Sheaves and Pin.

Serial Number: N/A Size: N/A

Manufacture: Seatrax Material: Carbon Steel Qty:06

Specification: BS EN 1711 Reference Drawing N°:N/A Comment: Area Inspected: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the all critical and accessible of the Stbd Crane Sheaves and Pin. Result: No defects or indications were found at time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: yes

Name / Qualification: Rafael Cardoso/ ASNT II

ET-4331

Signed / Stamp:

Date of Inspection: 04/07/2014

Approved By:

Equipments

Page 45: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 2 of 5

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

EDDY CURRENT INSPECTION REPORT

Client: Transocean Report Number: QT-EC-1053-37 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Stbd Crane Sheaves and Pin. Inspection Details: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the Stbd Crane Sheaves and Pin.

Name / Qualification: Rafael Cardoso/ ASNT II

ET-4331

Signed / Stamp:

Date of Inspection: 29/06/2014

Approved By:

Inspected Areas

Page 46: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 3 of 5

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

EDDY CURRENT INSPECTION REPORT

Client: Transocean Report Number: QT-EC-1053-37 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Stbd Crane Sheaves and Pin Inspection Details: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the Stbd Crane Sheaves and Pin.

Name / Qualification: Rafael Cardoso/ ASNT II

ET-4331

Signed / Stamp:

Date of Inspection: 29/06/2014

Approved By:

Inspected Areas

Page 47: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 4 of 5

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-54 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Stbd Crane Pin Sheaves. Qty: 01 Size: N/A

Serial Number: N/A Reference Drawing N°: N/A

Specification: Seatrax Material: Carbon Steel Manufacture: N/A

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Stbd Crane Pin Sheaves. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: No Comments.

Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 04/07/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

x

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type: Natural x Artificial

Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip Equipment Description: Voltage: 220v Serial No:1949

Test Method Test Medium Dry Colour Wet x Wet Fluorescent

Particle Type: SEV-300

Contrast Type: n/a

Antifoaming Type: n/a

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: n/a

Maker: n/a

Model: N/A

Batch Nr: 17393

Batch Nr: n/a

Batch Nr: n/a

Serial Nr: N/A

Page 48: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 5 of 5

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety safety

RP-QT-104 Rev. 0

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-54 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Stbd Crane Pin Sheaves.

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Stbd Crane Pin Sheaves. No defects were found on time of inspection.

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 04/07/2014

Approved By:

Page 49: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 1 of 8

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-045 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Manual Tong HT 100 Qty: 01(6 Piece) Size: N/A Serial Number: TC112339, TC109540, TC111314, TC110858, TC112673 Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture: NOV

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Manual Tong. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use.

Continuation Attached: Yes

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II MT-2444

Signed / Stamp:

Date of Inspection: 21/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 50: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 2 of 8

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-045 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Manual Tong

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Manual Tong. No defects were found on time of inspection.

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II MT-2444

Signed / Stamp:

Date of Inspection: 21/06/2014

Approved By:

Page 51: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 3 of 8

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-046 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Manual Tong HT 100 Qty: 06 Size: N/A Serial Number: TC111330, TC106472, TC112334, TC109344, TC112675 Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture: NOV

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Manual Tong. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use.

Continuation Attached: Yes

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II MT-2444

Signed / Stamp:

Date of Inspection: 21/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 52: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 4 of 8

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-046 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Manual Tong

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Manual Tong. No defects were found on time of inspection.

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II MT-2444

Signed / Stamp:

Date of Inspection: 21/06/2014

Approved By:

Page 53: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 5 of 8

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-01 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Manual Tong HT 100 (Test Hinge Jaw) Qty: 02 Piece Size: N/A

Serial Number: 00622, TC103631 Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture: NOV

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Manual Tong HT 100 (Test Hinge Jaw). Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use.

Continuation Attached: Yes

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II

Signed / Stamp:

Date of Inspection: 16/07/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 54: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 6 of 8

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-01 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Manual Tong HT 100 (Test Hinge Jaw)

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Manual Tong HT 100 (Test Hinge Jaw). No defects were found on time of inspection.

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II

Signed / Stamp:

Date of Inspection: 16/07/2014

Approved By:

Page 55: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 7 of 8

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-02 P.O. Nr: WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: Surface: Clean

Equipment Description: Manual Tong HT 100 (Test Latch Lug Jaw) Qty: 02 Piece Size: N/A

Serial Number: TC106875, TC114896 Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture: NOV

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Manual Tong HT 100 (Test Latch Lug Jaw). Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use.

Continuation Attached: Yes

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II

Signed / Stamp:

Date of Inspection: 16/07/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 56: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 8 of 8

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-02 P.O. Nr: WO: 1053 Location: Sedco 706

Item: Manual Tong HT 100 (Test Latch Lug Jaw)

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Manual Tong HT 100 (Test Latch Lug Jaw). No defects were found on time of inspection.

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II

Signed / Stamp:

Date of Inspection: 16/07/2014

Approved By:

Page 57: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 1 of 11

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Fugro Location: Sedco 706 Report Number: QT-MPI-1053-01 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Rov Base Structure. Qty: 02 Size: N/A

Serial Number: N/A Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture:

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Rov Base Structure. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use.

Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 10/07/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 58: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 2 of 11

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Fugro Report Number: QT-MPI-1053-01 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Rov Base Structure.

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Rov Base Structure. No defects were found on time of inspection.

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 10/07/2014

Approved By:

Page 59: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 3 of 11

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Fugro Location: Sedco 706 Report Number: QT-MPI-1053-02 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Rov Base Structure. Qty: 11 Size: N/A

Serial Number: N/A Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture:

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Rov Base Structure. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use. Continuation Attached: Yes

Name / Qualification: Paulo Vitor B. Paraiba

ASNT II

Signed / Stamp:

Date of Inspection: 16/07/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 60: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 4 of 11

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Fugro Report Number: QT-MPI-1053-02 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Rov Base Structure.

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Rov Base Structure. No defects were found on time of inspection.

Name / Qualification: Paulo Vitor B. Paraiba

ASNT II

Signed / Stamp:

Date of Inspection: 16/07/2014

Approved By:

Page 61: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 5 of 11

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Fugro Report Number: QT-MPI-1053-02 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Rov Base Structure.

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Rov Base Structure. No defects were found on time of inspection.

Name / Qualification: Paulo Vitor B. Paraiba

ASNT II

Signed / Stamp:

Date of Inspection: 16/07/2014

Approved By:

Page 62: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 6 of 11

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Fugro Report Number: QT-MPI-1053-02 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Rov Base Structure.

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Rov Base Structure. No defects were found on time of inspection.

Name / Qualification: Paulo Vitor B. Paraiba

ASNT II

Signed / Stamp:

Date of Inspection: 16/07/2014

Approved By:

Page 63: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 7 of 11

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Fugro Report Number: QT-MPI-1053-02 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Rov Base Structure.

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Rov Base Structure. No defects were found on time of inspection.

Name / Qualification: Paulo Vitor B. Paraiba

ASNT II

Signed / Stamp:

Date of Inspection: 16/07/2014

Approved By:

Page 64: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 8 of 11

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-58 P.O. Nr: N/A WO: QT-1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Rov Base Structure. Qty: 01 Size: N/A

Serial Number: N/A Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture:

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Rov Base Structure. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: No Comments.

Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 10/07/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 65: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 9 of 11

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-58 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Rov Base Structure.

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Rov Base Structure. No defects were found on time of inspection.

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 10/07/2014

Approved By:

Page 66: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 10 of 11

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-58 P.O. Nr:N/A WO: 1053 Location: Sedco 706

Item: Rov Base Structure.

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Rov Base Structure. No defects were found on time of inspection.

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 10/07/2014

Approved By:

Page 67: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 11 of 11

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-58 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Rov Base Structure.

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Rov Base Structure. No defects were found on time of inspection.

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 10/07/2014

Approved By:

Page 68: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 1 of 2

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-056 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Flex Joint Adapter. Qty: 04 Size: 6 Ton

Serial Number: N/A Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture:

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Flex Joint Adapter. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue Use. Continuation Attached: Yes

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II MT-2444

Signed / Stamp:

Date of Inspection: 21/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 69: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 2 of 2

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-056 P.O. Nr: WO: 1053 Location: Sedco 706

Item: Flex Joint Adapter.

Inspection Details: Magnetic Particle Inspection was carried out on Flex Joint Adapter Neck. No defects were found on time of inspection.

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II MT-2444

Signed / Stamp:

Date of Inspection: 21/06/2014

Approved By:

Page 70: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 1 of 2

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-049 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Weld of line HP Cement (Drill floor) Qty: 01 Size: N/A

Serial Number: N/A Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture: N/A

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Weld of line HP Cement (Drill floor). Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use.

Continuation Attached: Yes

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II MT-2444

Signed / Stamp:

Date of Inspection: 21/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 71: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 2 of 2

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-049 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Weld of line HP Cement (Drill floor)

Inspection Details: Magnetic Particle Inspection was carried out on Weld of line HP Cement (Drill floor). No defects were found on time of inspection.

Name / Qualification: Paulo Vitor B. Paraiba/

ASNT II MT-2444

Signed / Stamp:

Date of Inspection: 21/06/2014

Approved By:

Page 72: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 1 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-022 P.O. Nr: N/A WO: QT-1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Life boat 1. Qty: 01 Size: N/A

Serial Number: GH764519-A 1906238 Reference Drawing N°: N/A Specification: ASME Sec.V Material: Carbon Steel Manufacture: N/A

Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Life boat 1. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use. Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 30/05/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 73: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 2 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-022 P.O. Nr: N/A WO: QT-1053 Location: Sedco 706

Item: Lifeboat 1.

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the lifeboat 1. No defects were found on time of inspection.

Name / Qualification:

Rafael Cardoso/ ASNT II MT-5007

Signed / Stamp:

Date of Inspection: 30/05/2014

Approved By:

Page 74: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 3 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-023 P.O. Nr: N/A WO: QT-1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Life boat 2. Qty: 01 Size: N/A

Serial Number: GH764519-A 1406252R Reference Drawing N°: N/A Specification: ASME Sec.V Material: Carbon Steel Manufacture: N/A

Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Life boat 2. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use. Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 30/05/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 75: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 4 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-023 P.O. Nr: N/A WO: QT-1053 Location: Sedco 706

Item: Lifeboat 2.

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the lifeboat 2. No defects were found on time of inspection.

Name / Qualification:

Rafael Cardoso/ ASNT II MT-5007

Signed / Stamp:

Date of Inspection: 30/05/2014

Approved By:

Page 76: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 1 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-036 P.O. Nr: N/A WO: QT-1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Lifeboat 1 and 2 Wedge Socket. Qty: 04 Size: N/A

Serial Number: N/A Reference Drawing N°: N/A Specification: ASME Sec.V Material: Carbon Steel Manufacture: N/A

Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Lifeboat 1 and 2 Wedge Socket. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use. Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 08/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 77: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 2 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-036 P.O. Nr: N/A WO: QT-1053 Location: Sedco 706

Item: Lifeboat 1 and 2 Wedge Socket.

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Lifeboat 1 and 2 Wedge Socket. No defects were found on time of inspection.

Name / Qualification:

Rafael Cardoso/ ASNT II MT-5007

Signed / Stamp:

Date of Inspection: 08/06/2014

Approved By:

Lifeboat 1 Lifeboat 2

Page 78: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 3 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-024 P.O. Nr: N/A WO: QT-1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Lifeboat 3 and 4 Wedge Socket. Qty: 04 Size: N/A

Serial Number: N/A Reference Drawing N°: N/A Specification: ASME Sec.V Material: Carbon Steel Manufacture: N/A

Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Lifeboat 3 and 4 Wedge Socket. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use. Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 04/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 79: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 4 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-024 P.O. Nr: N/A WO: QT-1053 Location: Sedco 706

Item: Lifeboat 3 and 4 Wedge Socket.

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Lifeboat 3 and 4 Wedge Socket. No defects were found on time of inspection.

Name / Qualification:

Rafael Cardoso/ ASNT II MT-5007

Signed / Stamp:

Date of Inspection: 04/06/2014

Approved By:

Lifeboat 3 Lifeboat 4

Page 80: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 1 of 6

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-041 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Travelling Block connections points. Qty: 01 Size: N/A

Serial Number: N/A Reference Drawing N°: N/A Specification: ASME SEC.V Material: Carbon Steel Manufacture: NOV

Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Travelling Block connections points. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: No Comments. Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 11/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 81: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 2 of 6

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-041 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Drill String Compensator.

Inspection Details: Magnetic Particle Inspection was carried out at the Drill String Compensator. No defects were found on time of inspection.

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 11/06/2014

Approved By:

Inspected Areas

Page 82: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 3 of 6

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-042 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Drill String Compensator. Qty: 01 Size: N/A

Serial Number: N/A Reference Drawing N°: N/A Specification: ASME SEC.V Material: Carbon Steel Manufacture: NOV

Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Drill String Compensator. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: No Comments. Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 11/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 83: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 4 of 6

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-042 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Drill String Compensator.

Inspection Details: Magnetic Particle Inspection was carried out at the Drill String Compensator. No defects were found on time of inspection.

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 11/06/2014

Approved By:

Page 84: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 5 of 6

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-043 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Drill String Compensator. Qty: 01 Size: N/A

Serial Number: N/A Reference Drawing N°: N/A Specification: ASME SEC.V Material: Carbon Steel Manufacture: NOV

Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Drill String Compensator. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use. Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 11/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 85: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 6 of 6

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-043 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Drill String Compensator.

Inspection Details: Magnetic Particle Inspection was carried out at the Drill String Compensator. No defects were found on time of inspection.

Name / Qualification:

Rafael Cardoso/ ASNT II MT-5007

Signed / Stamp:

Date of Inspection: 11/06/2014

Approved By:

Page 86: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 1 of 2

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-044 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Rbs Clevis Point. Qty: 01 Size: N/A

Serial Number: N/A Reference Drawing N°: N/A Specification: ASME Sec. V Material: Carbon Steel Manufacture: N/A

Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on the accessible critical and stress areas of the Rbs Clevis Point. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use. Continuation Attached: Yes

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 11/06/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 87: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 2 of 2

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-044 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Rbs Clevis Point.

Inspection Details: Magnetic Particle Inspection was carried out on the Rbs Clevis Point. No defects were found on time of inspection.

Name / Qualification: Rafael Cardoso/ ASNT II

MT-5007

Signed / Stamp:

Date of Inspection: 11/06/2014

Approved By:

Page 88: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 1 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-01 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Flare Boom Base Structure (Aft Port). Qty: 02 Size: N/A

Serial Number: N/A Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture:

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Flare Boom Base Structure (Aft Port). Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use.

Continuation Attached: Yes

Name / Qualification: Paulo Vitor Paraiba

ASNT II

Signed / Stamp:

Date of Inspection: 15/07/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 89: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 2 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-01 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Flare Boom Base Structure (Aft Port).

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Flare Boom Base Structure (Aft Port). No defects were found on time of inspection.

Name / Qualification: Paulo Vitor Paraiba

ASNT II

Signed / Stamp:

Date of Inspection: 15/07/2014

Approved By:

Page 90: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 3 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-02 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1

Client PMS Number: N/A Surface: Clean

Equipment Description: Flare Boom Base Structure (Aft Star). Qty: 02 Size: N/A

Serial Number: N/A Reference Drawing N°: N/A

Specification: ASME V Material: Carbon Steel Manufacture:

Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Flare Boom Base Structure (Aft Star). Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use.

Continuation Attached: Yes

Name / Qualification: Paulo Vitor Paraiba

ASNT II

Signed / Stamp:

Date of Inspection: 20/07/2014

Approved By:

Equipment/Magnetization

Magnetization Technique

Coil

Magnetization : Longitudinal Current Flow : Alternating

Ligth Type:

x Natural Artificial

x Yoke Pull 10lbs

Yes Pole Spacing:

4” to 6 “ Ilumination:

1000 lux Flux Indicator:

Berthold x Burmah Strip

Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949

Test Method Test Medium Dry X Colour Wet Wet Fluorescent

Particle Type: SEV-300

Contrast Type: 104

Antifoaming Type: BC 502

Black Light Unit: N/A

FL/Sample AT:

UV:04 at 0,1

Visible:04 at 0,1L

Batch No:

Maker: SERV END

Maker: Metal Check

Maker: Metal Check

Model: N/A

Batch Nr: 17393

Batch Nr: 13901

Batch Nr: 17393

Serial Nr: N/A

Page 91: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Page 4 of 4

Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240

www.qualitechirm.com Quality for safety

RP-QT-097B Rev. 1

MAGNETIC PARTICLE INSPECTION REPORT

Client: Transocean Report Number: QT-MPI-1053-02 P.O. Nr: N/A WO: 1053 Location: Sedco 706

Item: Flare Boom Base Structure (Aft Star).

Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Flare Boom Base Structure (Aft Star). No defects were found on time of inspection.

Name / Qualification: Paulo Vitor Paraiba

ASNT II

Signed / Stamp:

Date of Inspection: 20/07/2014

Approved By:

Page 92: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 93: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 94: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 95: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 96: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 97: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 98: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 99: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 100: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:

Certificamos que PAULO VITOR BRUNO PARAIBA, portando o CPF 110.573.477-36 concluiu com aproveitamento o curso de NR-33 Segurança e Saúde nos Trabalhos em Espaços Confinados (Trabalhadores Autorizados e Vigias), com carga horária de 16 horas. Oferecido pela empresa QUALITECH INSPECAO, REPARO E MANUTENCAO LTDA. Realizado no período de 07/05/2014 a 23/05/2014.

Rio de Janeiro (RJ), 23 de Maio de 2014.

Page 101: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 102: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 103: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 104: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 105: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 106: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 107: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 108: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 109: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 110: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 111: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 112: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 113: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure:
Page 114: CLIENT: TRANSOCEAN LOCATION: SEDCO 706 · 2014-09-10 · Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure: