RP-QT-127B Rev.0
QUALITECH INSPECTION, REPAIR AND MAINTENACE LTD.
GENERAL NDT INSPECTIONS
CLIENT: TRANSOCEAN
LOCATION: SEDCO 706
PO N°: 1334050 WO N°: 1053/1
Date: 12/08/2014 Version: Original Volume: 1 of 1
RP-QT-127B Rev.0
CONTENT
SECTION 01 - EXECUTIVE SUMMARY REPORT
SECTION 02 – WORK BASKETS
SECTION 03 – STBD AND PORT BOP CRANE & HOOKS AFTER THE LOAD TEST
SECTION 04 – BOP PAD EYES LIFTING CONNECTOR
SECTION 05 – BOP LIFTING CONNECTOR PAD EYE
SECTION 06 – PEDESTAL PORT CRANE & ASSOCIATED EQUIPMENTS
SECTION 07 – STBD CRANE & ASSOCIATED EQUIPMENTS
SECTION 08 – MANUAL TONG AND PARTS
SECTION 09 – ROV SUPPORT BASE
SECTION 10 – FLEX JOINT ADAPTER
SECTION 11 – HP CEMENT LINE WELD
SECTION 12 – LIFEBOAT 1 AND 2 SUPPORT DAVIT
SECTION 13 – LIFEBOATS WEDGE SOCKETS
SECTION 14 – DRILL STRING COMPENSATOR
SECTION 15 – RBS CLEVIS POINT
SECTION 16 – FLARE BOOM BASE STRUCTURE
SECTION 17 – TECHINICIAN CERTIFICATE
SECTION 18 – COMPANY CERTIFICATE
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-150 Rev. 1
CERTIFICATE OF THOROUGH EXAMINATION
Health and Safety, The Lifting Operations and Lifting Equipment Regulations 1998 Statutory Instruments 1998 No. 2307 Customer: Transocean Certificate Number: QT-1053-001 Location: Sedco 706 Date of Thorough Examination: 11/03/2014
Manufacturer: Safe Lift Offshore LTDA Equipment Status: New
Equipment: Basket Serial Number: SOL / 9816/1 Manufacture Date: N/A Tare: 200 Kg SWL:1.500 Kg
Area Inspected: As per clients request a 100% Visual Inspection was carried out on offshore container and lifting equipment’s fitted Following L.O.L.E.R. Procedures. Fitting Equipments: 1 Set of four leg wire rope sling SWL 4 Ton Te: SERIAL NUMBER: SOL / 9816/1A 1 Set of four Shackles Safety Pin Bow SWL 3.25 Ton Te: SERIAL NUMBER: 16/1B 16/1C 16/1D 16/1E Results: No defects or injurious were found on time of inspection. Recommendations: Acceptable to Specification.
Name / Qualification: Paulo Vitor Paraiba
ASNT / II
Signed / Stamp: Date of Inspection: 17/07/2014
Approved by:
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-150 Rev. 1
CERTIFICATE OF THOROUGH EXAMINATION
Health and Safety, The Lifting Operations and Lifting Equipment Regulations 1998 Statutory Instruments 1998 No. 2307 Customer: Transocean Certificate Number: QT-1053-002 Location: Sedco 706 Date of Thorough Examination: 11/03/2014
Manufacturer: Safe Lift Offshore LTDA Equipment Status: New
Equipment: Basket Serial Number: SOL / 9816/2 Manufacture Date:N/A Tare: 200 Kg SWL: 1.500 Kg Area Inspected: As per clients request a 100% Visual Inspection was carried out on offshore container and lifting equipment’s fitted Following L.O.L.E.R. Procedures. Fitting Equipments: 1 Set of four leg wire rope sling SWL 4 Ton Te: SERIAL NUMBER: SOL / 9816/2A 1 Set of four Shackles Safety Pin Bow SWL 3.25 Ton Te: SERIAL NUMBER: 16/2B 16/2C 16/2D 16/2E Results: No defects or injurious were found on time of inspection. Recommendations: Acceptable to Specification.
Name / Qualification: Paulo Vitor Paraiba
ASNT II
Signed / Stamp: Date of Inspection: 17/07/2014
Approved by:
Page 1 of 14
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
EDDY CURRENT INSPECTION REPORT
Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-36 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure: PI-QT-06 Rev.0
Client PMS Number: N/A Surface: Painted
Probes Probes Serial No Frequency Gain Phase Calibration
PWM100S000 502016/01 100Khz 40 db 321 DEG 3 db for every 0.5mm PWM100S000 501943/01 100Khz 47 db 291 DEG 1mm Slot to SFH NOTE: Compensations made for variable geometry and paint thickness. Equipment Description: BOP Crane Stbd.
Serial Number: N/A Size: N/A
Manufacture: N/A Material: N/A Qty:01
Specification: BS EN 1711 Reference Drawing N°:N/A Comment: Area Inspected: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the all critical and accessible of the BOP Crane Stbd after Load Test. Result: No defects or indications were found at time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: yes
Name / Qualification: Rafael Cardoso/ ASNT II
ET-4331
Signed / Stamp:
Date of Inspection: 29/06/2014
Approved By:
Equipments
Page 2 of 14
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
EDDY CURRENT INSPECTION REPORT
Client: Transocean Report Number: QT-EC-1053-36 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: BOP Crane Stbd. Inspection Details: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the BOP Crane Stbd after load test.
Name / Qualification: Rafael Cardoso/ ASNT II
ET-4331
Signed / Stamp:
Date of Inspection: 29/06/2014
Approved By:
Inspected Areas
Page 3 of 14
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
EDDY CURRENT INSPECTION REPORT
Client: Transocean Report Number: QT-EC-1053-36 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: BOP Crane Stbd. Inspection Details: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the BOP Crane Stbd After Load Test.
Name / Qualification: Rafael Cardoso/ ASNT II
ET-4331
Signed / Stamp:
Date of Inspection: 29/06/2014
Approved By:
Inspected Areas
Page 4 of 14
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
EDDY CURRENT INSPECTION REPORT
Client: Transocean Date: 29/06/2014 WO:1053 Report Number: QT-EC-1053-37 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure: PI-QT-06 Rev.0
Client PMS Number: Surface: Painted
Probes Probes Serial No Frequency Gain Phase Calibration
PWM100S000 502016/01 100Khz 40 db 321 DEG 3 db for every 0.5mm PWM100S000 501943/01 100Khz 47 db 291 DEG 1mm Slot to SFH NOTE: Compensations made for variable geometry and paint thickness. Equipment Description: BOP Crane Port.
Serial Number:N/A Size: N/A
Manufacture: N/A Material: N/A Qty:01
Specification: BS EN 1711 Reference Drawing N°:N/A Comment: Area Inspected: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the all critical and accessible of the BOP Crane Port after Load Test. Result: No defects or indications were found at time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: yes
Name / Qualification: Rafael Cardoso/ ASNT II
ET-4331
Signed / Stamp:
Date of Inspection: 29/06/2014
Approved By:
Equipments
Page 5 of 14
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
EDDY CURRENT INSPECTION REPORT
Client: Transocean Report Number: QT-EC-1053-37 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: BOP Crane Port. Inspection Details: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the BOP Crane Port after load test.
Name / Qualification: Rafael Cardoso/ ASNT II
ET-4331
Signed / Stamp:
Date of Inspection: 29/06/2014
Approved By:
Inspected Areas
Page 6 of 14
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
EDDY CURRENT INSPECTION REPORT
Client: Transocean Report Number: QT-EC-1053-37 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: BOP Crane Port after load test. Inspection Details: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the BOP Crane Port after load test.
Name / Qualification:
Rafael Cardoso/ ASNT II ET-4331
Signed / Stamp:
Date of Inspection: 29/06/2014
Approved By:
Inspected Areas
Page 7 of 14
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-050 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number:N/A Surface: Clean
Equipment Description: BOP Crane STBD plate and pin 80 Tons. Qty: 01 Size: 80 ton
Serial Number: 0757284 Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture:
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the BOP Crane STBD plate and pin 80 Tons. Result: No defects were found on time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification.
Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 29/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type: x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 8 of 14
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-050 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: BOP Crane STBD plate and pin 80 Tons.
Inspection Details: Magnetic Particle Inspection was carried out on the BOP Crane STBD plate and pin 80 Tons.No defects were found on time of inspection.
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 29/06/2014
Approved By:
Page 9 of 14
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-051 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number:N/A Surface: Clean
Equipment Description: BOP Crane PORT plate and pin 80 Tons. Qty: 01 Size: 80 ton
Serial Number: 0757283 Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture:
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the BOP Crane PORT plate and pin 80 Tons. Result: No defects were found on time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification.
Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 29/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type: x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 10 of 14
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-051 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: BOP Crane PORT plate and pin 80 Tons.
Inspection Details: Magnetic Particle Inspection was carried out on the BOP Crane PORT plate and pin 80 Tons.No defects were found on time of inspection.
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 29/06/2014
Approved By:
Page 11 of 14
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-052 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: BOP Crane STBD Hook. Qty: 01 Size: 15 ton
Serial Number: 0757283 Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture: N/A
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the BOP Crane STBD Hook. Result: No defects were found on time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification.
Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 29/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type: x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 12 of 14
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-052 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: BOP Crane STBD Hook.
Inspection Details: Magnetic Particle Inspection was carried out on the BOP Crane STBD Hook. No defects were found on time of inspection.
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 29/06/2014
Approved By:
Page 13 of 14
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-053 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: BOP Crane PORT Hook. Qty: 01 Size: 15 ton
Serial Number: 0757284 Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture:
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the BOP Crane PORT Hook. Result: No defects were found on time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification.
Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 29/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type: x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 14 of 14
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-053 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: BOP Crane PORT Hook.
Inspection Details: Magnetic Particle Inspection was carried out on BOP Crane PORT Hook. No defects were found on time of inspection.
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 29/06/2014
Approved By:
Page 1 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-046 P.O. Nr: N/A WO: QT-1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Pad eyes BOP Lifting Connector Qty: 04 Size: 6 Ton
Serial Number:N/A Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture:
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Pad eyes BOP Lifting Connector. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use.
Continuation Attached: Yes
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II MT-2444
Signed / Stamp:
Date of Inspection: 21/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 2 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-046 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Pad eyes BOP Lifting Connector
Inspection Details: Magnetic Particle Inspection was carried out on Pad eyes BOP Lifting Connector. No defects were found on time of inspection.
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II MT-2444
Signed / Stamp:
Date of Inspection: 21/06/2014
Approved By:
Page 3 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-047 P.O. Nr: N/A WO: QT-1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Pad eyes BOP Lifting Connector Qty: 04 Size: 6 Ton
Serial Number: N/A Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture:
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Padeyes BOP Lifting Connector Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use.
Continuation Attached: Yes
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II MT-2444
Signed / Stamp:
Date of Inspection: 21/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 4 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-047 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Pad eyes BOP Lifting Connector
Inspection Details: Magnetic Particle Inspection was carried out on the Pad eyes BOP Lifting Connector. No defects were found on time of inspection.
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II MT-2444
Signed / Stamp:
Date of Inspection: 21/06/2014
Approved By:
Page 1 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-046 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Padeyes BOP Lifting Connector Qty: 04 Size: 6 Ton
Serial Number:N/A Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture:
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Pad eyes BOP Lifting Connector. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use.
Continuation Attached: Yes
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II MT-2444
Signed / Stamp:
Date of Inspection: 21/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 2 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-046 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Padeyes BOP Lifting Connector
nspection Details: Magnetic Particle Inspection was carried out on Pad eyes BOP Lifting Connector. No defects were found on time of inspection.
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II MT-2444
Signed / Stamp:
Date of Inspection: 21/06/2014
Approved By:
Page 3 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-047 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Pad eyes BOP Lifting Connector Qty: 04 Size: 6 Ton
Serial Number:N/A Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture:
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Pad eyes BOP Lifting Connector Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use.
Continuation Attached: Yes
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II MT-2444
Signed / Stamp:
Date of Inspection: 21/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 4 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-047 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Padeyes BOP Lifting Connector
Inspection Details: Magnetic Particle Inspection was carried out on the Pad eyes BOP Lifting Connector. No defects were found on time of inspection.
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II MT-2444
Signed / Stamp:
Date of Inspection: 21/06/2014
Approved By:
Page 1 of 15
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
EDDY CURRENT INSPECTION REPORT
Client: Transocean Date: 07/07/2014 WO:1053 Report Number: QT-EC-1053-38 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure: PI-QT-06 Rev.0
Client PMS Number: Surface: Painted
Probes Probes Serial No Frequency Gain Phase Calibration
PWM100S000 502016/01 100Khz 40 db 321 DEG 3 db for every 0.5mm PWM100S000 501943/01 100Khz 47 db 291 DEG 1mm Slot to SFH NOTE: Compensations made for variable geometry and paint thickness. Equipment Description: Port Crane Pedestal.
Serial Number: N/A Size: N/A
Manufacture: Seatrax Material: Carbon Steel Qty:06
Specification: BS EN 1711 Reference Drawing N°:N/A Comment: Area Inspected: As per clients request a 10% Visual and Eddy Current Inspection was carried out on the all critical and accessible of the Port Crane Pedestal. Result: No defects or indications were found at time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: yes
Name / Qualification: Rafael Cardoso/ ASNT II
ET-4331
Signed / Stamp:
Date of Inspection: 07/07/2014
Approved By:
Equipments
Page 2 of 15
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
EDDY CURRENT INSPECTION REPORT
Client: Transocean Report Number: QT-EC-1053-38 P.O. Nr: N/A WO:1053 Location: Sedco 706
Item: Port Crane Pedestal. Inspection Details: As per clients request a 10% Visual and Eddy Current Inspection was carried out on the Port Crane Pedestal.
Name / Qualification:
Rafael Cardoso/ ASNT II ET-4331
Signed / Stamp:
Date of Inspection: 07/07/2014
Approved By:
Inspected Areas
Page 3 of 15
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
EDDY CURRENT INSPECTION REPORT
Client: Transocean Report Number: QT-EC-1053-38 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Port Crane Pedestal. Inspection Details: As per clients request a 10% Visual and Eddy Current Inspection was carried out on the Port Crane Pedestal.
Name / Qualification: Rafael Cardoso/ ASNT II
ET-4331
Signed / Stamp:
Date of Inspection: 07/07/2014
Approved By:
Inspected Areas
Page 4 of 15
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
EDDY CURRENT INSPECTION REPORT
Client: Transocean Date: 07/07/2014 WO:1053 Report Number: QT-EC-1053-39 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure: PI-QT-06 Rev.0
Client PMS Number: Surface: Painted
Probes Probes Serial No Frequency Gain Phase Calibration
PWM100S000 502016/01 100Khz 40 db 321 DEG 3 db for every 0.5mm PWM100S000 501943/01 100Khz 47 db 291 DEG 1mm Slot to SFH NOTE: Compensations made for variable geometry and paint thickness. Equipment Description: Port Crane A-Frame
Serial Number: N/A Size: N/A
Manufacture: Seatrax Material: Carbon Steel Qty:01
Specification: BS EN 1711 Reference Drawing N°:N/A Comment: Area Inspected: As per clients request a 10% Visual and Eddy Current Inspection was carried out on the all critical and accessible of the Port Crane A-Frame. Result: No defects or indications were found at time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: yes
Name / Qualification: Rafael Cardoso/ ASNT II
ET-4331
Signed / Stamp:
Date of Inspection: 07/07/2014
Approved By:
Equipments
Page 5 of 15
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
EDDY CURRENT INSPECTION REPORT
Client: Transocean Report Number: QT-EC-1053-39 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Port Crane A-Frame. Inspection Details: As per clients request a 10% Visual and Eddy Current Inspection was carried out on the Port Crane A-Frame.
Name / Qualification: Rafael Cardoso/ ASNT II
ET-4331
Signed / Stamp:
Date of Inspection: 07/07/2014
Approved By:
Inspected Areas
Page 6 of 15
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
EDDY CURRENT INSPECTION REPORT
Client: Transocean Report Number: QT-EC-1053-39 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Port Crane A-Frame. Inspection Details: As per clients request a 10% Visual and Eddy Current Inspection was carried out on the Port Crane A-Frame.
Name / Qualification: Rafael Cardoso/ ASNT II
ET-4331
Signed / Stamp:
Date of Inspection: 07/07/2014
Approved By:
Inspected Areas
Page 7 of 15
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
EDDY CURRENT INSPECTION REPORT
Client: Transocean Date: 07/07/2014 WO:1053 Report Number: QT-EC-1053-40 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure: PI-QT-06 Rev.0
Client PMS Number: Surface: Painted
Probes Probes Serial No Frequency Gain Phase Calibration
PWM100S000 502016/01 100Khz 40 db 321 DEG 3 db for every 0.5mm PWM100S000 501943/01 100Khz 47 db 291 DEG 1mm Slot to SFH NOTE: Compensations made for variable geometry and paint thickness. Equipment Description: Port Crane Boom.
Serial Number: N/A Size: N/A
Manufacture: Seatrax Material: Carbon Steel Qty:01
Specification: BS EN 1711 Reference Drawing N°:N/A Comment: Area Inspected: As per clients request a 10% Visual and Eddy Current Inspection was carried out on the all critical and accessible of the Port Crane Boom. Result: No defects or indications were found at time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: yes
Name / Qualification: Rafael Cardoso/ ASNT II
ET-4331
Signed / Stamp:
Date of Inspection: 07/07/2014
Approved By:
Equipments
Page 8 of 15
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
EDDY CURRENT INSPECTION REPORT
Client: Transocean Report Number: QT-EC-1053-40 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Port Crane Boom. Inspection Details: As per clients request a 10% Visual and Eddy Current Inspection was carried out on the Port Crane Boom.
Name / Qualification: Rafael Cardoso/ ASNT II
ET-4331
Signed / Stamp:
Date of Inspection: 07/07/2014
Approved By:
Inspected Areas
Page 9 of 15
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-55 P.O. Nr: N/A WO: QT-1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Port Crane Pedestal. Qty: 01 Size: N/A
Serial Number: N/A Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture: N/A
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Port Crane Pedestal. Result: No defects were found on time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 07/07/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 10 of 15
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-55 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Port Crane Pedestal.
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Port Crane Pedestal.. No defects were found on time of inspection.
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 07/07/2014
Approved By:
Page 11 of 15
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-55 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Port Crane Pedestal.
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Port Crane Pedestal.. No defects were found on time of inspection.
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 07/07/2014
Approved By:
Page 12 of 15
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-56 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number:N/A Surface: Clean
Equipment Description: Port Crane Main Hook . Qty: 01 Size: 49.1 ton
Serial Number: N/A Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture: Seatrax
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Port Crane Main Hook . Result: No defects were found on time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 07/07/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 13 of 15
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-56 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Port Crane Main Hook.
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Port Crane Main Hook. No defects were found on time of inspection.
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 07/07/2014
Approved By:
Page 14 of 15
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-57 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Port Crane Auxiliary Hook . Qty: 01 Size: 49.1 ton
Serial Number: N/A Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture: Seatrax
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Port Crane Auxiliary Hook . Result: No defects were found on time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 07/07/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type: x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 15 of 15
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-57 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Port Crane Auxiliary Hook .
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Port Crane Auxiliary Hook . No defects were found on time of inspection.
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 07/07/2014
Approved By:
Page 1 of 5
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
EDDY CURRENT INSPECTION REPORT
Client: Transocean Date: 04/07/2014 WO:1053 Report Number: QT-EC-1053-37 P.O. Nr: N/A Location: Sedco 706 Inspection Procedure: PI-QT-06 Rev.0
Client PMS Number: N/A Surface: Painted
Probes Probes Serial No Frequency Gain Phase Calibration
PWM100S000 502016/01 100Khz 40 db 321 DEG 3 db for every 0.5mm PWM100S000 501943/01 100Khz 47 db 291 DEG 1mm Slot to SFH NOTE: Compensations made for variable geometry and paint thickness. Equipment Description: Stbd Crane Sheaves and Pin.
Serial Number: N/A Size: N/A
Manufacture: Seatrax Material: Carbon Steel Qty:06
Specification: BS EN 1711 Reference Drawing N°:N/A Comment: Area Inspected: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the all critical and accessible of the Stbd Crane Sheaves and Pin. Result: No defects or indications were found at time of inspection. Conclusion: All items inspected were found in good condition. Recommendations: Acceptable to Specification. Continuation Attached: yes
Name / Qualification: Rafael Cardoso/ ASNT II
ET-4331
Signed / Stamp:
Date of Inspection: 04/07/2014
Approved By:
Equipments
Page 2 of 5
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
EDDY CURRENT INSPECTION REPORT
Client: Transocean Report Number: QT-EC-1053-37 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Stbd Crane Sheaves and Pin. Inspection Details: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the Stbd Crane Sheaves and Pin.
Name / Qualification: Rafael Cardoso/ ASNT II
ET-4331
Signed / Stamp:
Date of Inspection: 29/06/2014
Approved By:
Inspected Areas
Page 3 of 5
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
EDDY CURRENT INSPECTION REPORT
Client: Transocean Report Number: QT-EC-1053-37 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Stbd Crane Sheaves and Pin Inspection Details: As per clients request a 100% Visual and Eddy Current Inspection was carried out on the Stbd Crane Sheaves and Pin.
Name / Qualification: Rafael Cardoso/ ASNT II
ET-4331
Signed / Stamp:
Date of Inspection: 29/06/2014
Approved By:
Inspected Areas
Page 4 of 5
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-54 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Stbd Crane Pin Sheaves. Qty: 01 Size: N/A
Serial Number: N/A Reference Drawing N°: N/A
Specification: Seatrax Material: Carbon Steel Manufacture: N/A
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Stbd Crane Pin Sheaves. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: No Comments.
Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 04/07/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
x
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type: Natural x Artificial
Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip Equipment Description: Voltage: 220v Serial No:1949
Test Method Test Medium Dry Colour Wet x Wet Fluorescent
Particle Type: SEV-300
Contrast Type: n/a
Antifoaming Type: n/a
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: n/a
Maker: n/a
Model: N/A
Batch Nr: 17393
Batch Nr: n/a
Batch Nr: n/a
Serial Nr: N/A
Page 5 of 5
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety safety
RP-QT-104 Rev. 0
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-54 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Stbd Crane Pin Sheaves.
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Stbd Crane Pin Sheaves. No defects were found on time of inspection.
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 04/07/2014
Approved By:
Page 1 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-045 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Manual Tong HT 100 Qty: 01(6 Piece) Size: N/A Serial Number: TC112339, TC109540, TC111314, TC110858, TC112673 Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Manual Tong. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use.
Continuation Attached: Yes
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II MT-2444
Signed / Stamp:
Date of Inspection: 21/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 2 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-045 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Manual Tong
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Manual Tong. No defects were found on time of inspection.
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II MT-2444
Signed / Stamp:
Date of Inspection: 21/06/2014
Approved By:
Page 3 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-046 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Manual Tong HT 100 Qty: 06 Size: N/A Serial Number: TC111330, TC106472, TC112334, TC109344, TC112675 Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Manual Tong. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use.
Continuation Attached: Yes
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II MT-2444
Signed / Stamp:
Date of Inspection: 21/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 4 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-046 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Manual Tong
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Manual Tong. No defects were found on time of inspection.
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II MT-2444
Signed / Stamp:
Date of Inspection: 21/06/2014
Approved By:
Page 5 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-01 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Manual Tong HT 100 (Test Hinge Jaw) Qty: 02 Piece Size: N/A
Serial Number: 00622, TC103631 Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Manual Tong HT 100 (Test Hinge Jaw). Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use.
Continuation Attached: Yes
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II
Signed / Stamp:
Date of Inspection: 16/07/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 6 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-01 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Manual Tong HT 100 (Test Hinge Jaw)
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Manual Tong HT 100 (Test Hinge Jaw). No defects were found on time of inspection.
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II
Signed / Stamp:
Date of Inspection: 16/07/2014
Approved By:
Page 7 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-02 P.O. Nr: WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: Surface: Clean
Equipment Description: Manual Tong HT 100 (Test Latch Lug Jaw) Qty: 02 Piece Size: N/A
Serial Number: TC106875, TC114896 Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Manual Tong HT 100 (Test Latch Lug Jaw). Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use.
Continuation Attached: Yes
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II
Signed / Stamp:
Date of Inspection: 16/07/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 8 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-02 P.O. Nr: WO: 1053 Location: Sedco 706
Item: Manual Tong HT 100 (Test Latch Lug Jaw)
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Manual Tong HT 100 (Test Latch Lug Jaw). No defects were found on time of inspection.
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II
Signed / Stamp:
Date of Inspection: 16/07/2014
Approved By:
Page 1 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Fugro Location: Sedco 706 Report Number: QT-MPI-1053-01 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Rov Base Structure. Qty: 02 Size: N/A
Serial Number: N/A Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture:
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Rov Base Structure. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use.
Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 10/07/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 2 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Fugro Report Number: QT-MPI-1053-01 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Rov Base Structure.
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Rov Base Structure. No defects were found on time of inspection.
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 10/07/2014
Approved By:
Page 3 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Fugro Location: Sedco 706 Report Number: QT-MPI-1053-02 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Rov Base Structure. Qty: 11 Size: N/A
Serial Number: N/A Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture:
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Rov Base Structure. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use. Continuation Attached: Yes
Name / Qualification: Paulo Vitor B. Paraiba
ASNT II
Signed / Stamp:
Date of Inspection: 16/07/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 4 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Fugro Report Number: QT-MPI-1053-02 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Rov Base Structure.
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Rov Base Structure. No defects were found on time of inspection.
Name / Qualification: Paulo Vitor B. Paraiba
ASNT II
Signed / Stamp:
Date of Inspection: 16/07/2014
Approved By:
Page 5 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Fugro Report Number: QT-MPI-1053-02 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Rov Base Structure.
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Rov Base Structure. No defects were found on time of inspection.
Name / Qualification: Paulo Vitor B. Paraiba
ASNT II
Signed / Stamp:
Date of Inspection: 16/07/2014
Approved By:
Page 6 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Fugro Report Number: QT-MPI-1053-02 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Rov Base Structure.
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Rov Base Structure. No defects were found on time of inspection.
Name / Qualification: Paulo Vitor B. Paraiba
ASNT II
Signed / Stamp:
Date of Inspection: 16/07/2014
Approved By:
Page 7 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Fugro Report Number: QT-MPI-1053-02 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Rov Base Structure.
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Rov Base Structure. No defects were found on time of inspection.
Name / Qualification: Paulo Vitor B. Paraiba
ASNT II
Signed / Stamp:
Date of Inspection: 16/07/2014
Approved By:
Page 8 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-58 P.O. Nr: N/A WO: QT-1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Rov Base Structure. Qty: 01 Size: N/A
Serial Number: N/A Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture:
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Rov Base Structure. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: No Comments.
Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 10/07/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 9 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-58 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Rov Base Structure.
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Rov Base Structure. No defects were found on time of inspection.
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 10/07/2014
Approved By:
Page 10 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-58 P.O. Nr:N/A WO: 1053 Location: Sedco 706
Item: Rov Base Structure.
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Rov Base Structure. No defects were found on time of inspection.
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 10/07/2014
Approved By:
Page 11 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-58 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Rov Base Structure.
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Rov Base Structure. No defects were found on time of inspection.
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 10/07/2014
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-056 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Flex Joint Adapter. Qty: 04 Size: 6 Ton
Serial Number: N/A Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture:
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Flex Joint Adapter. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue Use. Continuation Attached: Yes
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II MT-2444
Signed / Stamp:
Date of Inspection: 21/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-056 P.O. Nr: WO: 1053 Location: Sedco 706
Item: Flex Joint Adapter.
Inspection Details: Magnetic Particle Inspection was carried out on Flex Joint Adapter Neck. No defects were found on time of inspection.
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II MT-2444
Signed / Stamp:
Date of Inspection: 21/06/2014
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-049 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Weld of line HP Cement (Drill floor) Qty: 01 Size: N/A
Serial Number: N/A Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture: N/A
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Weld of line HP Cement (Drill floor). Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use.
Continuation Attached: Yes
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II MT-2444
Signed / Stamp:
Date of Inspection: 21/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-049 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Weld of line HP Cement (Drill floor)
Inspection Details: Magnetic Particle Inspection was carried out on Weld of line HP Cement (Drill floor). No defects were found on time of inspection.
Name / Qualification: Paulo Vitor B. Paraiba/
ASNT II MT-2444
Signed / Stamp:
Date of Inspection: 21/06/2014
Approved By:
Page 1 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-022 P.O. Nr: N/A WO: QT-1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Life boat 1. Qty: 01 Size: N/A
Serial Number: GH764519-A 1906238 Reference Drawing N°: N/A Specification: ASME Sec.V Material: Carbon Steel Manufacture: N/A
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Life boat 1. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use. Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 30/05/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 2 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-022 P.O. Nr: N/A WO: QT-1053 Location: Sedco 706
Item: Lifeboat 1.
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the lifeboat 1. No defects were found on time of inspection.
Name / Qualification:
Rafael Cardoso/ ASNT II MT-5007
Signed / Stamp:
Date of Inspection: 30/05/2014
Approved By:
Page 3 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-023 P.O. Nr: N/A WO: QT-1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Life boat 2. Qty: 01 Size: N/A
Serial Number: GH764519-A 1406252R Reference Drawing N°: N/A Specification: ASME Sec.V Material: Carbon Steel Manufacture: N/A
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Life boat 2. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use. Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 30/05/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 4 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-023 P.O. Nr: N/A WO: QT-1053 Location: Sedco 706
Item: Lifeboat 2.
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the lifeboat 2. No defects were found on time of inspection.
Name / Qualification:
Rafael Cardoso/ ASNT II MT-5007
Signed / Stamp:
Date of Inspection: 30/05/2014
Approved By:
Page 1 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-036 P.O. Nr: N/A WO: QT-1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Lifeboat 1 and 2 Wedge Socket. Qty: 04 Size: N/A
Serial Number: N/A Reference Drawing N°: N/A Specification: ASME Sec.V Material: Carbon Steel Manufacture: N/A
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Lifeboat 1 and 2 Wedge Socket. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use. Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 08/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 2 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-036 P.O. Nr: N/A WO: QT-1053 Location: Sedco 706
Item: Lifeboat 1 and 2 Wedge Socket.
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Lifeboat 1 and 2 Wedge Socket. No defects were found on time of inspection.
Name / Qualification:
Rafael Cardoso/ ASNT II MT-5007
Signed / Stamp:
Date of Inspection: 08/06/2014
Approved By:
Lifeboat 1 Lifeboat 2
Page 3 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-024 P.O. Nr: N/A WO: QT-1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Lifeboat 3 and 4 Wedge Socket. Qty: 04 Size: N/A
Serial Number: N/A Reference Drawing N°: N/A Specification: ASME Sec.V Material: Carbon Steel Manufacture: N/A
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Lifeboat 3 and 4 Wedge Socket. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use. Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 04/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 4 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-024 P.O. Nr: N/A WO: QT-1053 Location: Sedco 706
Item: Lifeboat 3 and 4 Wedge Socket.
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Lifeboat 3 and 4 Wedge Socket. No defects were found on time of inspection.
Name / Qualification:
Rafael Cardoso/ ASNT II MT-5007
Signed / Stamp:
Date of Inspection: 04/06/2014
Approved By:
Lifeboat 3 Lifeboat 4
Page 1 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-041 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Travelling Block connections points. Qty: 01 Size: N/A
Serial Number: N/A Reference Drawing N°: N/A Specification: ASME SEC.V Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Travelling Block connections points. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: No Comments. Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 11/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 2 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-041 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Drill String Compensator.
Inspection Details: Magnetic Particle Inspection was carried out at the Drill String Compensator. No defects were found on time of inspection.
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 11/06/2014
Approved By:
Inspected Areas
Page 3 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-042 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Drill String Compensator. Qty: 01 Size: N/A
Serial Number: N/A Reference Drawing N°: N/A Specification: ASME SEC.V Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Drill String Compensator. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: No Comments. Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 11/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 4 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-042 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Drill String Compensator.
Inspection Details: Magnetic Particle Inspection was carried out at the Drill String Compensator. No defects were found on time of inspection.
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 11/06/2014
Approved By:
Page 5 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-043 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Drill String Compensator. Qty: 01 Size: N/A
Serial Number: N/A Reference Drawing N°: N/A Specification: ASME SEC.V Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Drill String Compensator. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use. Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 11/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 6 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-043 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Drill String Compensator.
Inspection Details: Magnetic Particle Inspection was carried out at the Drill String Compensator. No defects were found on time of inspection.
Name / Qualification:
Rafael Cardoso/ ASNT II MT-5007
Signed / Stamp:
Date of Inspection: 11/06/2014
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-044 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Rbs Clevis Point. Qty: 01 Size: N/A
Serial Number: N/A Reference Drawing N°: N/A Specification: ASME Sec. V Material: Carbon Steel Manufacture: N/A
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on the accessible critical and stress areas of the Rbs Clevis Point. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the Use. Continuation Attached: Yes
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 11/06/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-044 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Rbs Clevis Point.
Inspection Details: Magnetic Particle Inspection was carried out on the Rbs Clevis Point. No defects were found on time of inspection.
Name / Qualification: Rafael Cardoso/ ASNT II
MT-5007
Signed / Stamp:
Date of Inspection: 11/06/2014
Approved By:
Page 1 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-01 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Flare Boom Base Structure (Aft Port). Qty: 02 Size: N/A
Serial Number: N/A Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture:
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Flare Boom Base Structure (Aft Port). Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use.
Continuation Attached: Yes
Name / Qualification: Paulo Vitor Paraiba
ASNT II
Signed / Stamp:
Date of Inspection: 15/07/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 2 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-01 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Flare Boom Base Structure (Aft Port).
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Flare Boom Base Structure (Aft Port). No defects were found on time of inspection.
Name / Qualification: Paulo Vitor Paraiba
ASNT II
Signed / Stamp:
Date of Inspection: 15/07/2014
Approved By:
Page 3 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Location: Sedco 706 Report Number: QT-MPI-1053-02 P.O. Nr: N/A WO: 1053 Inspection Procedure: PI-QT-003 Rev.1
Client PMS Number: N/A Surface: Clean
Equipment Description: Flare Boom Base Structure (Aft Star). Qty: 02 Size: N/A
Serial Number: N/A Reference Drawing N°: N/A
Specification: ASME V Material: Carbon Steel Manufacture:
Comment: Area Inspected: As per clients request a 100% Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical and stress areas of the Flare Boom Base Structure (Aft Star). Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue to Use.
Continuation Attached: Yes
Name / Qualification: Paulo Vitor Paraiba
ASNT II
Signed / Stamp:
Date of Inspection: 20/07/2014
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “ Ilumination:
1000 lux Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Electromagnetic Yoke Voltage: 220v Serial No:1949
Test Method Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: SEV-300
Contrast Type: 104
Antifoaming Type: BC 502
Black Light Unit: N/A
FL/Sample AT:
UV:04 at 0,1
Visible:04 at 0,1L
Batch No:
Maker: SERV END
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 17393
Batch Nr: 13901
Batch Nr: 17393
Serial Nr: N/A
Page 4 of 4
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 16, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev. 1
MAGNETIC PARTICLE INSPECTION REPORT
Client: Transocean Report Number: QT-MPI-1053-02 P.O. Nr: N/A WO: 1053 Location: Sedco 706
Item: Flare Boom Base Structure (Aft Star).
Inspection Details: Magnetic Particle Inspection was carried out on corroded areas at the Flare Boom Base Structure (Aft Star). No defects were found on time of inspection.
Name / Qualification: Paulo Vitor Paraiba
ASNT II
Signed / Stamp:
Date of Inspection: 20/07/2014
Approved By:
Certificamos que PAULO VITOR BRUNO PARAIBA, portando o CPF 110.573.477-36 concluiu com aproveitamento o curso de NR-33 Segurança e Saúde nos Trabalhos em Espaços Confinados (Trabalhadores Autorizados e Vigias), com carga horária de 16 horas. Oferecido pela empresa QUALITECH INSPECAO, REPARO E MANUTENCAO LTDA. Realizado no período de 07/05/2014 a 23/05/2014.