[email protected] www.linac-world.de Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente, Ulrich Ratzinger, Holger Podlech, R.Tiede, R.Brodhage, L.Groening GSI, Darmstadt, Germany J.W. Goethe-Universität, Frankfurt am Main, Germany HIPPI ANNUAL Meeting, CERN, GENEVA October 29 th , 2008

Transcript of [email protected]@gsi.de Development of the Room Temperature CH-DTL in the frame of the...

Page 1: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project

Gianluigi Clemente, Ulrich Ratzinger,

Holger Podlech, R.Tiede, R.Brodhage, L.Groening

GSI, Darmstadt, GermanyJ.W. Goethe-Universität, Frankfurt am Main, Germany

HIPPI ANNUAL Meeting, CERN, GENEVA

October 29th, 2008

Page 2: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

Topic

The Room Temperature CH-DTL in the Frame of HIPPI RF Properties Past activities

Status of the Coupled CH-DTL: Model and Prototype Future Plans

Page 3: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

GOAL OF THE PROJECT

For the GSI linac, with a final energy of approximately 70 MeV, the “KONUS” beam dynamics is foreseen with the use of H-mode structures over all the range of energies. Low power model cavities have to be built and measured, and a prototype 352 MHz CH cavity is proposed to be built and tested in a high power test stand at GSI or at CERN.

Construction of a cold model Construction of a warm RF model Construction of the first "FAIR" Prototype Investigation of the KONUS beam dynamics for a multi MeV Linac

ORIGINAL PLAN in Early 2004

Page 4: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

Why CH?

Highest Shunt impedance at low-medium beta profile

Existing H-Mode provided the highest accelerating gradient in those range of energy (10.5 MV/m at Cern linac 3)

High Resistance against electric breakdown

(Kl > 5 at Cern Linac 3)

Compact structure

Mechanical Robustness

Reduced number of focusing elements

Easy to be cooled

Page 5: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

First Model

8 cells ,β/2=45mm, total inner length 600 mm

Original Idea based on "Press-fit technique"

Copper

Copper Plated Stainless Steel

During the R&D development it was decided to build directly a warm model which could stand high RF level

Page 6: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

Tuning the end cells

Bt

dlE

The end half drift tube can host magnetic lens and a diagnostics device

Magnetic Tuning of the end cell

7

Page 7: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

Tuning concept

Final tuning is obtained by changing the Gap/Length along the cavity axis

Capacitive Tuning

8

Page 8: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

The first CH-DTL

Cooling system:

8 water pipes (2 per quadrant) on the outer tank

Hollow stems with own water connection

6

Copper plating:

Successfully performed at the GSI galvanic workshop,

average thickness: 40 μm

Welding:

Stems welded from inside, leak test successful

Construction of the first room temperature CH-DTL

Page 9: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

The first CH-DTL: Results

Main Results:

• Reliability of CH-DTL design in terms of mechanical construction, welding, and Copper Plating

• Measured Q0= 13000 (95 % of the ideal MWS Value)

• Measured Frequency 340 MHz ( 338.6 MHz Simulated )

• Test at 2 kW CW: no multipacting observed, stability of cavity’s temperature during long test operation ⇒ Proof of efficiency for the cooling system

Observed Problems: • Deformation of the drift tubes during the welding process: Press-fit technique no longer used

Page 10: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

Application to FAIR After LINAC 06 it was decided to feed the FAIR Proton Injector with the klystrons

developed for JPARC : Frequency: 352 MhZ 325.244 (3 times the UNILAC DTL frequency)⇒ Power: 13 klystrons, 0.8 MW ⇒ 7 klystron, 2.5 MW A coupled structure results to be the best choice to match the linac with such a high

power. No coupled H-Mode structure ever built up to now

A current flow like this would create the desired coupling

Page 11: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

The coupling concept was tested simulating CH resonators identical to the test model (8 gaps each with an intertank section of length 5 βλ)

Evidence of the coupling and of a parasite mode!

The Coupled CH

0 Mode

π / 2 Mode

Page 12: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

FAIR Coupled Resonator No 2

27 gaps including beta profile (generated by LORASR) (13+14) Energy Range: 11.7-24.3 MeV (β :0.15-0.22) Frequency: 325.2 MHz Q_0: 15300

Bandwidth ~ 21.2 kHz K ~ 0.5 % Kl: 2.0

ZT2: 60 MΩ/m RF LOSSES: 1.37 MW Beam Loading: 882 kW (at 70 mA, 35 required for the injection into the SIS 18) Total Power: 2.25 MW

Page 13: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

Scaled Model

Position of mobile tuners

Aluminium

Brass

Page 14: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

Stems without drift tubes: drift tubes can be exchanged for final tuning where needed (change of the gap/length ratio)

Scaled Model 1:2

Page 15: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

Scaled Model 1:2

First frequency Measurements in good agreement with simulations

Next H-Mode Harmonic

(Fm – F s)/ F s = 0.25% Km=0.56 (0.5 simulated)

Page 16: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

Field Distribution

SIMULATED WITH MWS

MEASURED !

Page 17: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

Prototype: Technical Drawing

Page 18: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

Prototype: Technical Drawing

Page 19: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

Prototype: Technical Drawings

Coupling SectionSection between two coupled structures

Page 20: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

Outlook and Next Step

An improved low level RF test bench has been built at IAP in the frame of a degree thesis (R.Brodhage)

Final Assessment of the coupled model is in progress Production of the real prototype is expected for 2009 Full Power test at 2.5 MW will be performed at the new test stand at GSI

Page 21: Clemente@gsi.deClemente@gsi.de  Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,

[email protected] www.linac-world.de

HIPPI Schedule

The original schedule foresaw the construction of a "cold model" to test the mechanical properties of the CH and a "full power" Prototype.

IAP delivered a high power prototype and developed the concept of coupled H-mode structure to exploit the 2.5 MW rf power provided by commercial amplifiers

However, this complex cavity is of course by far off the cost frame of our

HIPPI engagement. So, we think, that the two models produced during HIPPI including the RF investigations are covering the volume of CH-DTL development promised at the beginning quite well.