CERN IT Department
CH-1211 Genève 23
Switzerlandwww.cern.ch/
it
HP ProCurve 2910 Ethernet switch in CNRAD
April-June 2012
RadWG Meeting
04.02.2014
Gyorgy Balazs
CERN IT Department
CH-1211 Genève 23
Switzerlandwww.cern.ch/
it
Evaluation process
Project to replace the ~600 obsolete network switches (3COM 4400) on the Technical Network (TN) during LS1
HP ProCurve 2910 as main candidate
6 months of thorough testing to ensure performance and reliability.
Including tests:•Performance and feature tests
Ethernet switch in CNRAD 2/11
CERN IT Department
CH-1211 Genève 23
Switzerlandwww.cern.ch/
it
Evaluation process
Project to replace the ~600 obsolete network switches (3COM 3300) on the Technical Network (TN) all around CERN during LS1
HP ProCurve 2910 as main candidate
6 months of thorough testing to ensure performance and reliability.
Including tests :•Performance and feature tests•High temperature
Ethernet switch in CNRAD 3/11
CERN IT Department
CH-1211 Genève 23
Switzerlandwww.cern.ch/
it
Evaluation process
Project to replace the ~600 obsolete network switches (3COM 3300) on the Technical Network (TN) all around CERN during LS1
HP ProCurve 2910 as main candidate
6 months of thorough testing to ensure performance and reliability.
Including tests :•Performance and feature tests•High temperature •Dust
Ethernet switch in CNRAD 4/11
CERN IT Department
CH-1211 Genève 23
Switzerlandwww.cern.ch/
it
Evaluation process
Project to replace the ~600 obsolete network switches (3COM 3300) on the Technical Network (TN) all around CERN during LS1
HP ProCurve 2910 as main candidate
6 months of thorough testing to ensure performance and reliability.
Including tests :•Performance and feature tests•High temperature •Dust•Magnetic field
Ethernet switch in CNRAD 5/11
CERN IT Department
CH-1211 Genève 23
Switzerlandwww.cern.ch/
it
Evaluation process
Project to replace the ~600 obsolete network switches (3COM 3300) on the Technical Network (TN) all around CERN during LS1
HP ProCurve 2910 as main candidate
6 months of thorough testing to ensure performance and reliability.
Including tests :•Performance and feature tests•High temperature •Dust•Magnetic field•Power cycle
Ethernet switch in CNRAD 6/11
CERN IT Department
CH-1211 Genève 23
Switzerlandwww.cern.ch/
it
Evaluation process
Project to replace the ~600 obsolete network switches (3COM 3300) on the Technical Network (TN) all around CERN during LS1
HP ProCurve 2910 as main candidate
6 months of thorough testing to ensure performance and reliability.
Including tests :•Performance and feature tests•High temperature •Dust•Magnetic field•Power cycle•Radiation
TSG 46
Ethernet switch in CNRAD 7/11
CERN IT Department
CH-1211 Genève 23
Switzerlandwww.cern.ch/
it
3 switches with redundant power supplies deployed at TSG46Spirent STC traffic generator placed in CNGS control room
Radiation test setup
Goal to understand the limits, switch not deployed in radiated areas
Ethernet switch in CNRAD 8/11
CERN IT Department
CH-1211 Genève 23
Switzerlandwww.cern.ch/
it
Beam conditions
Run # DUT id Part typeFlux (1-MeV neutron
equivalent)(cm-2/POT
Flux (Hadron) (cm-2/POT)
Dose rate(GY/POT)
1 Switch
[1,2,3]
mixed 2.42 x 10-8 1.7 x 10-8 3.27 x 10-8
2 Switch
[4,5,6]
Run #1 irradiation from 15/03/2012 at 14:21-Switch[1,2,3] removed on 26/4/2012 Run #2 irradiation from 26/4/2012 at 12:52-Switch[4,5,6], RPS[1,2] removed on 27/6/2012
Ethernet switch in CNRAD 9/11
Switches 1,3: HP ProCurve 2910 24 portSwitches 2,4: HP ProCurve 2910 48 portSwitches 5,6: 3COM 4400 24 port modelRPS1: HP RPS620 external PSU 2 portsRPS2: HP RPS630 external PSU 1 port
CERN IT Department
CH-1211 Genève 23
Switzerlandwww.cern.ch/
it
Test results
Run # DUT id. Time Failures
observed
HEH Fluence [cm-2]
1MeV n equivalent [cm-
2]
Beam Intensity (pot)
Total dose [Gy(Si)]
1 Switch1,2,315/03/2012 14:21 to
20/03/2012 14:54PSU 8.92E7 1.25E8 4.95E15 0.016
1 Switch1,2,35/03/2012 14:21 to 21/03/2012 09:37
FATAL 8.96E7 1.25E8 5.04E15 0.0165
3 Switch4,5,626/04/2012 12:52 to
26/4/2012 13:50FATAL 9.11E7 1.29E8 5.065E15 0.0165
Ethernet switch in CNRAD 10/11
CERN IT Department
CH-1211 Genève 23
Switzerlandwww.cern.ch/
it
Conclusion
• Switches are very sensitive to radiation
• Power supplies (internal and external) are clearly the most sensitive parts
• Electrical circuit breakers activated on the wall sockets - probably single event latchups
• Comparison to the previously deployed model does not show a big difference
• As the previously serving switches, deployed in protected areas
• Today 90% deployment rate
Ethernet switch in CNRAD 11/11