C:Documents and SettingsIanMy DocumentsWORK … · accordance with AS/NZS 3500 and Council...

15
onplan pty ltd 0413 998 089 fax 5491 8389 0411 524 530 fax 5446 2214 po box 215, moffat beach qld 4551 [email protected] [email protected] qbsa 1123230 acn 125 105 928 abn 33 658 335 908 client date job no. scale (a3) IAN McKINVEN PAUL CURRIE sheet name issue drawn by initial sheet no. www.onplan.com.au 180 flaxton mill road, flaxton 1 : 1 22/03/2010 3:44:31 PM C:\Documents and Settings\Ian\My Documents\WORK PROJECTS\onplan\2010\1003 fuchs\1003 fuchs 2.rvt r. fuchs march 2010 1003 cover approval im 0 issued for construction purposes revisions A concept 08/02/10 B concept revision 16/02/10 C preliminary 22/02/10 D approval 22/03/10 onplan

Transcript of C:Documents and SettingsIanMy DocumentsWORK … · accordance with AS/NZS 3500 and Council...

Page 1: C:Documents and SettingsIanMy DocumentsWORK … · accordance with AS/NZS 3500 and Council Regulations. 8. All earthworks , footings and slabs in accordance with Engineers design

onplan pty ltd0413 998 089 fax 5491 8389

0411 524 530 fax 5446 2214

po box 215, moffat beach qld 4551

[email protected] [email protected]

qbsa 1123230

acn 125 105 928 abn 33 658 335 908

clientdate

job no.

scale (a3)

IAN McKINVEN

PAUL CURRIE

sheet name

issue

drawn by

initial

sheet no.

www.onplan.com.au180 flaxton mill road, flaxton

1 : 122/03/2010 3:44:31 PM

C:\D

ocum

ents

an

d S

ettin

gs\Ian

\My D

ocum

en

ts\W

OR

K P

RO

JE

CT

S\o

npla

n\2

010

\100

3 fuchs\1

003

fuch

s 2

.rvt

r. fuchsmarch 2010

1003

cover

approval

im

0

issued forconstruction

purposes

revisionsA concept 08/02/10

B concept revision 16/02/10

C preliminary 22/02/10

D approval 22/03/10

onplan

Page 2: C:Documents and SettingsIanMy DocumentsWORK … · accordance with AS/NZS 3500 and Council Regulations. 8. All earthworks , footings and slabs in accordance with Engineers design

402000

403000

404000

405000

406000

407000

408000

409000

410000

411000

412000

413000

414000

415000

416000

417000

417

000

418000

41900

0

42000

0

42100

0

422000

42300

0

56 72071 0

60

112 8

50

70 2001576

30820

27457

flaxto

n m

ill r

oad

existing retaining wall

proposed 700 high retaining wall

swimming pool

residence

workshop

402 530

416

704

422

810

dp dp

dp dp dp dp

700 cut

entryportico

existing driveway

power pole

power pole

ele

ctr

ica

l lin

e

onplan pty ltd0413 998 089 fax 5491 8389

0411 524 530 fax 5446 2214

po box 215, moffat beach qld 4551

[email protected] [email protected]

qbsa 1123230

acn 125 105 928 abn 33 658 335 908

clientdate

job no.

scale (a3)

IAN McKINVEN

PAUL CURRIE

sheet name

issue

drawn by

initial

sheet no.

www.onplan.com.au180 flaxton mill road, flaxton

1 : 50022/03/2010 3:44:32 PM

C:\D

ocum

ents

an

d S

ettin

gs\Ian

\My D

ocum

en

ts\W

OR

K P

RO

JE

CT

S\o

npla

n\2

010

\100

3 fuchs\1

003

fuch

s 2

.rvt

r. fuchsmarch 2010

1003

site plan

approval

im

1

issued forconstruction

purposes

rainwater tanks - qdc part 25

Part 25 of the Queensland Development Code set outthe requirements for rainwater tanks including:Minimum capacity 5000 litresConnected to all WC's and washing machine cold tapsConnected to external taps15 litre first flush diverterTop up system from town waterOverflow to stormwater systemRainhead to shed leaves - mesh size 4-6mmMosquito proof screens max 1mm metal mesh sizeBackflow prevention deviceCatchment area, 1/2 roof or 100m²Refer QDC Part 25 for full details

qdc part 29;sustainable buildings

Building work in new class 1 buildings and sole-occupancyunits in Class 2 buildings are subject to water and energyefficiency measures effective from 1st March 2006 including:3 star rated or AAA rated shower roses;Pressure-limited devices; (In areas with reticulated mainswater supply, the maximum pressure level of water from anyoutlet within the property boundaries of a new Class 1building must not exceed 500kPa)Dual flush toilets;Energy-efficient lighting; (minimum 40% of floor areafluorescent or compact fluorescent lighting)Greenhouse-efficient hotwater system ie. Heat Pump, Solar,or 5 star Gas hot water system (Electric hot water systemsare no longer permitted for new dwellings)

proposed areasentry 2.65 m²

laundry deck 6.11 m²

master deck 26.73 m²

pool & decks 63.09 m²

residence 216.14 m²

studio deck 23.63 m²

workshop 36.05 m²

Grand total 374.40 m²

general notes

1. Figured dimensions take precedence over scaleddimensions.2. All work to comply with BCA, QLD Building Act and LocalAuthority Regulations.3. Site to be cut and filled in accordance with GeotechnicalEngineers specifications. All levels to be confirmed on site proirto construction.4. Excavations to be in accordance with BCA 3.1.1 andEngineers design.5. Drainage work to comply with Geotechnical Engineersrecommendations and the Structural Engineers details.6. All timber framing to comply with AS 1684.2.7. All plumbing and drainage work to be carried out inaccordance with AS/NZS 3500 and Council Regulations.8. All earthworks , footings and slabs in accordance withEngineers design and details.9. Termite protection to AS 3660-1. (Termimesh or equal)10. Driveway and crossovers to be in accordance withCouncils standard drawing details.11. Consulting engineers details and specifications are to takeprecedence over these drawings.12. Landscape works to be confirmed by client

RPDlot

parish ofcounty oflocality:

area:

rp 8104345

kenilworthmarch

sunshine coastregional council

5208m²

total site cover 374.40m² (7.2%)

revisionsA concept 08/02/10

B concept revision 16/02/10

C preliminary 22/02/10

D approval 22/03/10

onplan

Page 3: C:Documents and SettingsIanMy DocumentsWORK … · accordance with AS/NZS 3500 and Council Regulations. 8. All earthworks , footings and slabs in accordance with Engineers design

bedroom 2bedroom 3

bath

studiot&g flooring

workshopply flooring

master bedroomt&g flooring

ensuitetile flooring

wirt&g flooring

laundry

garage

garden

dining

lounge2

77

0 lo

ng

ref

swimming pool

timber retaining wall under

glass screen

clothes line

sto

re

gla

ss s

cre

en

robe

robe

master deck

tv

batten screen

ba

tte

n s

cre

en

pantry

35

0m

m s

he

lvin

g

entry

a

13

b

13

b

13

wet edge

poolequipmentunder

water tankunder deck

35

0m

m s

he

lvin

g

rem

ovable

raili

ng/b

arr

ier

max. 900m

m t

o g

round

dog door

pool weir belowmin. 1200 from topof weir to waterline

300 deep

shelvingover

1000 wide

fireplace

dp dp

dp dp dp dp

batten screen

pool fe

nce t

o c

ouncil

regula

tions

gate

entry portico over

pool fe

nce t

o c

ouncil

regula

tions

hwd decking

hwd posts

100

100

100

100

100

100

workshopply flooring

rem

ovable

raili

ng/b

arr

ier

max. 900m

m t

o g

round

c

14

dp dp

onplan pty ltd0413 998 089 fax 5491 8389

0411 524 530 fax 5446 2214

po box 215, moffat beach qld 4551

[email protected] [email protected]

qbsa 1123230

acn 125 105 928 abn 33 658 335 908

clientdate

job no.

scale (a3)

IAN McKINVEN

PAUL CURRIE

sheet name

issue

drawn by

initial

sheet no.

www.onplan.com.au180 flaxton mill road, flaxton

1 : 10022/03/2010 3:44:35 PM

C:\D

ocum

ents

an

d S

ettin

gs\Ian

\My D

ocum

en

ts\W

OR

K P

RO

JE

CT

S\o

npla

n\2

010

\100

3 fuchs\1

003

fuch

s 2

.rvt

r. fuchsmarch 2010

1003

floor plan

approval

im

2

issued forconstruction

purposes

1 : 100

floor plan

revisionsA concept 08/02/10

B concept revision 16/02/10

C preliminary 22/02/10

D approval 22/03/10

proposed areasentry 2.65 m²

laundry deck 6.11 m²

master deck 26.73 m²

pool & decks 63.09 m²

residence 216.14 m²

studio deck 23.63 m²

workshop 36.05 m²

Grand total 374.40 m²

1 : 100

workshop planonplan

Page 4: C:Documents and SettingsIanMy DocumentsWORK … · accordance with AS/NZS 3500 and Council Regulations. 8. All earthworks , footings and slabs in accordance with Engineers design

26730

6760 19970

90 6580 90

600

18890

5080

3180

1780

5140

3710

90

4900

90

1010

90

1990

90

1780

90

2800

90

2070

90

3620

90

1000

70

1000

600

870

70

3310

70

2850

70

960

75

4685

75 525

1780 90 2020 70

62070 960 440600 90 2290370

900

1855

2905

600 600

900 4160 15980 4490

90 3980 90 3840 100

1120

100

3345

100

3205

4340 12002

300

4050

400

600 3170 1810

3580 2000

2610

4140

1190

3650

3000

1100

1210

70

1010

70

2390

10290 70 3000 70

530

70 2200 70

530

70 2980 90

1200 1000

90 2120 90 2190

4310

90

3960

90

1190

90

3470

90

6090

900

100 1665

100

3345

100

3205

1950

onplan pty ltd0413 998 089 fax 5491 8389

0411 524 530 fax 5446 2214

po box 215, moffat beach qld 4551

[email protected] [email protected]

qbsa 1123230

acn 125 105 928 abn 33 658 335 908

clientdate

job no.

scale (a3)

IAN McKINVEN

PAUL CURRIE

sheet name

issue

drawn by

initial

sheet no.

www.onplan.com.au180 flaxton mill road, flaxton

1 : 10022/03/2010 3:44:36 PM

C:\D

ocum

ents

an

d S

ettin

gs\Ian

\My D

ocum

en

ts\W

OR

K P

RO

JE

CT

S\o

npla

n\2

010

\100

3 fuchs\1

003

fuch

s 2

.rvt

r. fuchsmarch 2010

1003

dimensions

approval

im

3

issued forconstruction

purposes

revisionsA concept 08/02/10

B concept revision 16/02/10

C preliminary 22/02/10

D approval 22/03/10

onplan

Page 5: C:Documents and SettingsIanMy DocumentsWORK … · accordance with AS/NZS 3500 and Council Regulations. 8. All earthworks , footings and slabs in accordance with Engineers design

timber sleeper retainingwalls for garden

400

4050

2300

800

1200 4860 3580 2000

9640

P1

P1

P1

P2

P2

P2 P2

P2P2

P2P2 P2

P2P3

P3

P3

P4

P4

P2 P2 P2

P2P2P2

swimming pool shell by others

swimming pool weir

75

1380

75

1375

75

1780

75 1425 75 1705

100

1020

100

2490

100

2425

100

2425

600 100 2380 100 2380 100 1910 100 1830 100

2520 100 1220 100

100

1535

100

3205

5080

3180

600

6760

19970

2190

1500

1255

100

1255

100

1920

100

1930

100 2095 100 2095 100

2380 2110 21640 4740

190

3650

1090

6090

740

pa

ne

l do

or

reb

ate

5100

250

500

sliding door rebate

1810 70

P1 - deck postP2 - house postP3 - deck postP4 - post for masterbed deck/studiodeck roof

workshop

4490 1500

70mm setdown forbathroom

90

2390

2200 3740

353 985 3430 985 985 985 985 985 705 985 955 985 840 985 985 800 985 945 985 123

75shs

2793 985 985 1998

6438 985 985 985 985 985 985 985 985 985 4148

P3 P3 P3

P4

P4

reinforced concrete blockbase

reinforced concrete slab to engineers requirements

onplan pty ltd0413 998 089 fax 5491 8389

0411 524 530 fax 5446 2214

po box 215, moffat beach qld 4551

[email protected] [email protected]

qbsa 1123230

acn 125 105 928 abn 33 658 335 908

clientdate

job no.

scale (a3)

IAN McKINVEN

PAUL CURRIE

sheet name

issue

drawn by

initial

sheet no.

www.onplan.com.au180 flaxton mill road, flaxton

1 : 10022/03/2010 3:44:37 PM

C:\D

ocum

ents

an

d S

ettin

gs\Ian

\My D

ocum

en

ts\W

OR

K P

RO

JE

CT

S\o

npla

n\2

010

\100

3 fuchs\1

003

fuch

s 2

.rvt

r. fuchsmarch 2010

1003

slab & post plan

approval

im

4

issued forconstruction

purposes

1. all dimensions are to/from outside of brickwork. confirm prior toconstruction2. slab plan to be read in conjunction with floor & dimension plans.3. footings and slab construction to be in accordance with the engineerssoil report and design.4. termite treatment to AS 3660-1.5. all positions of plumbing wastes are approximate only.6. min. -25mm fall to all floor wastes (fw)

note

revisionsA concept 08/02/10

B concept revision 16/02/10

C preliminary 22/02/10

D approval 22/03/10

onplan

Page 6: C:Documents and SettingsIanMy DocumentsWORK … · accordance with AS/NZS 3500 and Council Regulations. 8. All earthworks , footings and slabs in accordance with Engineers design

9530

2610

4490

4400 90

90

9350

90

2000

100 1665

P2 P2 P2

P3 P3 P3

P2

P2

P2

P2P2

9530

190

2273

100

2223

100

2223

100

2223

100

4490

6990

2540

4490 1500

block retaining wallto support workshop

block retainingwall to retain

backfill

onplan pty ltd0413 998 089 fax 5491 8389

0411 524 530 fax 5446 2214

po box 215, moffat beach qld 4551

[email protected] [email protected]

qbsa 1123230

acn 125 105 928 abn 33 658 335 908

clientdate

job no.

scale (a3)

IAN McKINVEN

PAUL CURRIE

sheet name

issue

drawn by

initial

sheet no.

www.onplan.com.au180 flaxton mill road, flaxton

1 : 10022/03/2010 3:44:38 PM

C:\D

ocum

ents

an

d S

ettin

gs\Ian

\My D

ocum

en

ts\W

OR

K P

RO

JE

CT

S\o

npla

n\2

010

\100

3 fuchs\1

003

fuch

s 2

.rvt

r. fuchsmarch 2010

1003

workshop layout

approval

im

5

issued forconstruction

purposes

revisionsD approval 22/03/10

1 : 100

workshop dimensions

1 : 100

workshop post layoutonplan

Page 7: C:Documents and SettingsIanMy DocumentsWORK … · accordance with AS/NZS 3500 and Council Regulations. 8. All earthworks , footings and slabs in accordance with Engineers design

wc

vanity

sh

fw

sink

tub

vanity

wc

2340

140

1240

840

dpdp

dp dp dp dp

dp dp

230

5410

5340

4700

2100

230

230 2420 1100 1310

830 4230

1660

1125

4835

5000Lrainwater

tank underdeck

590

onplan pty ltd0413 998 089 fax 5491 8389

0411 524 530 fax 5446 2214

po box 215, moffat beach qld 4551

[email protected] [email protected]

qbsa 1123230

acn 125 105 928 abn 33 658 335 908

clientdate

job no.

scale (a3)

IAN McKINVEN

PAUL CURRIE

sheet name

issue

drawn by

initial

sheet no.

www.onplan.com.au180 flaxton mill road, flaxton

1 : 10022/03/2010 3:44:39 PM

C:\D

ocum

ents

an

d S

ettin

gs\Ian

\My D

ocum

en

ts\W

OR

K P

RO

JE

CT

S\o

npla

n\2

010

\100

3 fuchs\1

003

fuch

s 2

.rvt

r. fuchsmarch 2010

1003

plumbing setout

approval

im

6

issued forconstruction

purposes

1. all dimensions are from outside wall face tocentre of plumbing fixture waste pipe2. contractor to check plumbing fixturesspecifications for fixture setout prior to construction3. wc offset from wall based on 140mm setout4. figured dimensions are supplied as an aid inassisting the contractor and will require checking bythe contractor prior to construction

note

revisionsA concept 08/02/10

B concept revision 16/02/10

C preliminary 22/02/10

D approval 22/03/10

onplan

Page 8: C:Documents and SettingsIanMy DocumentsWORK … · accordance with AS/NZS 3500 and Council Regulations. 8. All earthworks , footings and slabs in accordance with Engineers design

770 cav.sd

d22

770 cav.sd

d21

2418 sd

d7

820 cav.sd

d17

2151 panel lift

d9

243360 stackers

d5

820

d20

820

d11

820

d12

770

d13

1100 pivot

d1

2418 sd

d3

1200 ext sld

d15

2424 stackers

d2

770 cav.sd

d18

corner stackers

d4

820.

d8

2436 stackers

d23

2320 sld

d16

2320 sld

d10

2320 sld

d14

2418 sd

d6

820 ext sld

d19

2409 lvw13

2409 lvw12

2409 lvw11

2409 lvw10

2409 lv

w28

2409 lv

w27

2409 lv

w26

2409 lv

w25

2409 lvw1

2409 lvw2

2409 lvw3

2400 butt glw4

2409 lv

w30

2409 lv

w31

2409 lv

w34

0609 lv

w32

0609 lvw19

2409 lvw20

2400 butt glw18

2409 lvw9

2409 lv

w29

0609 lv

w33

2409 lv

w35

1209 lvw22

1209 lvw23

1209 lvw21

2409 lvw17

2409 lvw16

2409 lvw15

2400 butt glw14

2409 lv

w24

2409 lvw8

2409 lvw7

2409 lvw6

2409 lvw5

2409 lv

w44

2409 lvw45

2409 lvw36

2409 lv

w37

2436 stackers

d23

2409 lv

w3

2400 butt glw4

2400 butt glw42

2409 lvw41

2409 lvw40

2409 lvw39

2409 lv

w43

2409 lv

w44

2409 lvw45 2409 lv

w36

2409 lv

w37

2409 lv

w38

onplan pty ltd0413 998 089 fax 5491 8389

0411 524 530 fax 5446 2214

po box 215, moffat beach qld 4551

[email protected] [email protected]

qbsa 1123230

acn 125 105 928 abn 33 658 335 908

clientdate

job no.

scale (a3)

IAN McKINVEN

PAUL CURRIE

sheet name

issue

drawn by

initial

sheet no.

www.onplan.com.au180 flaxton mill road, flaxton

1 : 10022/03/2010 3:44:40 PM

C:\D

ocum

ents

an

d S

ettin

gs\Ian

\My D

ocum

en

ts\W

OR

K P

RO

JE

CT

S\o

npla

n\2

010

\100

3 fuchs\1

003

fuch

s 2

.rvt

r. fuchsmarch 2010

1003

openings

approval

im

7

issued forconstruction

purposes

door scheduled13 770

d14 2320 sld

d15 1200 ext sld

d16 2320 sld

d17 820 cav.sd

d18 770 cav.sd

d19 820 ext sld

d20 820

d21 770 cav.sd

d22 770 cav.sd

d23 2436 stackers

door scheduled1 1100 pivot

d2 2424 stackers

d3 2418 sd

d4 corner stackers

d5 243360 stackers

d6 2418 sd

d7 2418 sd

d8 820.

d9 2151 panel lift

d10 2320 sld

d11 820

d12 820

window schedulew36 2409 lv

w37 2409 lv

w38 2409 lv

w39 2409 lv

w40 2409 lv

w41 2409 lv

w42 2400 butt gl

w43 2409 lv

w44 2409 lv

w45 2409 lv

window schedulew24 2409 lv

w25 2409 lv

w26 2409 lv

w27 2409 lv

w28 2409 lv

w29 2409 lv

w30 2409 lv

w31 2409 lv

w32 0609 lv

w33 0609 lv

w34 2409 lv

w35 2409 lv

window schedulew13 2409 lv

w14 2400 butt gl

w15 2409 lv

w16 2409 lv

w17 2409 lv

w18 2400 butt gl

w19 0609 lv

w20 2409 lv

w21 1209 lv

w22 1209 lv

w23 1209 lv

window schedulew1 2409 lv

w2 2409 lv

w3 2409 lv

w4 2400 butt gl

w5 2409 lv

w6 2409 lv

w7 2409 lv

w8 2409 lv

w9 2409 lv

w10 2409 lv

w11 2409 lv

w12 2409 lv

revisionsA concept 08/02/10

B concept revision 16/02/10

C preliminary 22/02/10

D approval 22/03/10

1 : 100

workshop openingsonplan

Page 9: C:Documents and SettingsIanMy DocumentsWORK … · accordance with AS/NZS 3500 and Council Regulations. 8. All earthworks , footings and slabs in accordance with Engineers design

dpdp

dp dp dp dp

fall

workshop roof

900 overhang

600 overhang

600 overhang

600 overhang

600 overhang

60

0 o

verh

ang

60

0 o

verh

ang

60

0 o

verh

ang

60

0 o

verh

ang

60

0 o

verh

ang

600 overhang

60

0 o

verh

ang

60

0 o

verh

ang

dpdp

shs post totop platebeam over

fall

600 overhang

60

0 o

verh

ang

60

0 o

verh

ang

600 overhang

onplan pty ltd0413 998 089 fax 5491 8389

0411 524 530 fax 5446 2214

po box 215, moffat beach qld 4551

[email protected] [email protected]

qbsa 1123230

acn 125 105 928 abn 33 658 335 908

clientdate

job no.

scale (a3)

IAN McKINVEN

PAUL CURRIE

sheet name

issue

drawn by

initial

sheet no.

www.onplan.com.au180 flaxton mill road, flaxton

1 : 10022/03/2010 3:44:44 PM

C:\D

ocum

ents

an

d S

ettin

gs\Ian

\My D

ocum

en

ts\W

OR

K P

RO

JE

CT

S\o

npla

n\2

010

\100

3 fuchs\1

003

fuch

s 2

.rvt

r. fuchsmarch 2010

1003

roof layout

approval

im

10

issued forconstruction

purposes

roof schedule0.23 m²

main roof 340.23 m²

workshop roof 61.29 m²

Grand total 401.74 m²

gutter schedule33.02 m

Grand total 33.02 m

note:all areas & lengths shown are approximateonly. builder to confirm with suppliers priorto construction

revisionsA concept 08/02/10

B concept revision 16/02/10

C preliminary 22/02/10

D approval 22/03/10

1 : 100

workshop roof planonplan

Page 10: C:Documents and SettingsIanMy DocumentsWORK … · accordance with AS/NZS 3500 and Council Regulations. 8. All earthworks , footings and slabs in accordance with Engineers design

roof pitch5.00° roof pitch5.00°

fc68 clothesline

hb

shs

rbl

fc68

floor ht420.50 m

entry portico

sr

dp dp

gl gl gl

gara

ge w

indo

ws

21

00

hea

d h

eig

htbs

fc68

fc68

chimney flue

onplan pty ltd0413 998 089 fax 5491 8389

0411 524 530 fax 5446 2214

po box 215, moffat beach qld 4551

[email protected] [email protected]

qbsa 1123230

acn 125 105 928 abn 33 658 335 908

clientdate

job no.

scale (a3)

IAN McKINVEN

PAUL CURRIE

sheet name

issue

drawn by

initial

sheet no.

www.onplan.com.au180 flaxton mill road, flaxton

1 : 10022/03/2010 3:44:57 PM

C:\D

ocum

ents

an

d S

ettin

gs\Ian

\My D

ocum

en

ts\W

OR

K P

RO

JE

CT

S\o

npla

n\2

010

\100

3 fuchs\1

003

fuch

s 2

.rvt

r. fuchsmarch 2010

1003

elevations

approval

im

11

issued forconstruction

purposes

1 : 100

south elevation

1 : 100

west elevation

revisionsA concept 08/02/10

B concept revision 16/02/10

C preliminary 22/02/10

D approval 22/03/10

materials legendbs -batten screen to owners detail

dp -downpipes to plumbers/engineers specifications

fc68 -6mm fc cladding with 68 x 12mm horizontal cover battens. pvcjoiners at vertical join.

gl -glass louvres

hb -handrails & balustrading to bca 3.9.2 min. 1000mm above ffl

rbl -concrete block with applied render finish

shs -duragal shs posts to engineers specifications

sr -sheet metal roofing fixed to manufacturers specifications & details

onplan

Page 11: C:Documents and SettingsIanMy DocumentsWORK … · accordance with AS/NZS 3500 and Council Regulations. 8. All earthworks , footings and slabs in accordance with Engineers design

rough sawn cladding with35 x 70 battens

bs

fc68

fc68

fc68 75shs

bs

floor ht420.50 m

rwt

pool weir

pfhb

fc68

fc68

onplan pty ltd0413 998 089 fax 5491 8389

0411 524 530 fax 5446 2214

po box 215, moffat beach qld 4551

[email protected] [email protected]

qbsa 1123230

acn 125 105 928 abn 33 658 335 908

clientdate

job no.

scale (a3)

IAN McKINVEN

PAUL CURRIE

sheet name

issue

drawn by

initial

sheet no.

www.onplan.com.au180 flaxton mill road, flaxton

1 : 10022/03/2010 3:45:08 PM

C:\D

ocum

ents

an

d S

ettin

gs\Ian

\My D

ocum

en

ts\W

OR

K P

RO

JE

CT

S\o

npla

n\2

010

\100

3 fuchs\1

003

fuch

s 2

.rvt

r. fuchsmarch 2010

1003

elevations

approval

im

12

issued forconstruction

purposes

revisionsA concept 08/02/10

B concept revision 16/02/10

C preliminary 22/02/10

D approval 22/03/10

1 : 100

north elevation

1 : 100

east elevation

materials legend75shs -duragal 75mm shs posts to engineers specifications

bs -batten screen to owners detail

fc68 -6mm fc cladding with 68 x 12mm horizontal cover battens.pvc joiners at vertical join.

hb -handrails & balustrading to bca 3.9.2 min. 1000mm above ffl

pf -pool fencing to council regulations

rwt -5000L rainwater tank to council regulations

onplan

Page 12: C:Documents and SettingsIanMy DocumentsWORK … · accordance with AS/NZS 3500 and Council Regulations. 8. All earthworks , footings and slabs in accordance with Engineers design

2 studs out of internalcorners generally to

centrally locate doors

hinged door

slider doors

floor ht 420.50 m

djfj

pb

rt

srrt be

75shs

sr

bedroom 3 studiodp

hb

fj

shsshs shs rbl

level pad for car park

shs shs shscf

gl gl gl

typical

600

600

pb

cfcs

fbl

shssbsb

to top

of b

ea

m

3980

to to

p o

f w

all

3564

roof pitch 5.00°

to to

p o

f w

all

2962 tc

to to

p o

f w

all

3748

962

roof pitch 5.00°

bs

600

3392

floor ht 420.50 m

1475

spacings

250

2805

2796

roof pitch5.00°

at floor ht

1508

1753

90.00°

concrete step

150 x 150 galvanised portalwith welded tags for rafters

140 x 35 stained hwd rafters

concrete footings toengineers specifications

onplan pty ltd0413 998 089 fax 5491 8389

0411 524 530 fax 5446 2214

po box 215, moffat beach qld 4551

[email protected] [email protected]

qbsa 1123230

acn 125 105 928 abn 33 658 335 908

clientdate

job no.

scale (a3)

IAN McKINVEN

PAUL CURRIE

sheet name

issue

drawn by

initial

sheet no.

www.onplan.com.au180 flaxton mill road, flaxton

As indicated22/03/2010 3:45:13 PM

C:\D

ocum

ents

an

d S

ettin

gs\Ian

\My D

ocum

en

ts\W

OR

K P

RO

JE

CT

S\o

npla

n\2

010

\100

3 fuchs\1

003

fuch

s 2

.rvt

r. fuchsmarch 2010

1003

sections/details

approval

im

14

issued forconstruction

purposes

1 : 20

frame setout at openings

materials legend75shs -duragal 75mm shs posts to engineers specifications

be -beam to engineers specifications

bs -batten screen to owners detail

cf -concrete footings to engineers specifications & details

cs -concrete slab to engineers specifications & details

dj -deck joists to engineers specifications

dp -downpipes to plumbers/engineers specifications

fbl -face blockwork to engineers specifications

fj -floor joists to engineers specifications

gl -glass louvres

hb -handrails & balustrading to bca 3.9.2 min. 1000mm above ffl

pb -plasterboard lined ceilings & walls

rbl -concrete block with applied render finish

rt -rafters to engineers specifications

sb -galvanised steel rod bracing to engineers specifications

shs -duragal shs posts to engineers specifications

sr -sheet metal roofing fixed to manufacturers specifications & details

tc -timber frame construction to engineers specifications

revisionsA concept 08/02/10

B concept revision 16/02/10

C preliminary 22/02/10

D approval 22/03/10

1 : 100

section c

1 : 50

entry portal onplan

Page 13: C:Documents and SettingsIanMy DocumentsWORK … · accordance with AS/NZS 3500 and Council Regulations. 8. All earthworks , footings and slabs in accordance with Engineers design

s

s

symbol description number

2 GPO 11OO H

2 GPO 3OO H

1 GPO 11OO H

1 GPO 3OO H

downlight

ceiling fan

tv

ph phone

meter box

hotwaterhws

light point

rh

dw

rangehood

dishwasher

wo wall oven

stove

smoke alarm

Smoke alarms are to be hard wiredto mains power and shall complywith AS 3786 & BCA Vol. 2 3.7.2.

s

onplan pty ltd0413 998 089 fax 5491 8389

0411 524 530 fax 5446 2214

po box 215, moffat beach qld 4551

[email protected] [email protected]

qbsa 1123230

acn 125 105 928 abn 33 658 335 908

clientdate

job no.

scale (a3)

IAN McKINVEN

PAUL CURRIE

sheet name

issue

drawn by

initial

sheet no.

www.onplan.com.au180 flaxton mill road, flaxton

As indicated22/03/2010 3:45:15 PM

C:\D

ocum

ents

an

d S

ettin

gs\Ian

\My D

ocum

en

ts\W

OR

K P

RO

JE

CT

S\o

npla

n\2

010

\100

3 fuchs\1

003

fuch

s 2

.rvt

r. fuchsmarch 2010

1003

electrical

approval

im

15

issued forconstruction

purposes

revisionsA concept 08/02/10

B concept revision 16/02/10

C preliminary 22/02/10

D approval 22/03/10

1 : 100

workshop electricalonplan

Page 14: C:Documents and SettingsIanMy DocumentsWORK … · accordance with AS/NZS 3500 and Council Regulations. 8. All earthworks , footings and slabs in accordance with Engineers design

onplan pty ltd0413 998 089 fax 5491 8389

0411 524 530 fax 5446 2214

po box 215, moffat beach qld 4551

[email protected] [email protected]

qbsa 1123230

acn 125 105 928 abn 33 658 335 908

clientdate

job no.

scale (a3)

IAN McKINVEN

PAUL CURRIE

sheet name

issue

drawn by

initial

sheet no.

www.onplan.com.au180 flaxton mill road, flaxton

22/03/2010 3:45:27 PM

C:\D

ocum

ents

an

d S

ettin

gs\Ian

\My D

ocum

en

ts\W

OR

K P

RO

JE

CT

S\o

npla

n\2

010

\100

3 fuchs\1

003

fuch

s 2

.rvt

r. fuchsmarch 2010

1003

perspectives

approval

im

16

issued forconstruction

purposes

revisionsA concept 08/02/10

B concept revision 16/02/10

C preliminary 22/02/10

D approval 22/03/10

onplan

Page 15: C:Documents and SettingsIanMy DocumentsWORK … · accordance with AS/NZS 3500 and Council Regulations. 8. All earthworks , footings and slabs in accordance with Engineers design

onplan pty ltd0413 998 089 fax 5491 8389

0411 524 530 fax 5446 2214

po box 215, moffat beach qld 4551

[email protected] [email protected]

qbsa 1123230

acn 125 105 928 abn 33 658 335 908

clientdate

job no.

scale (a3)

IAN McKINVEN

PAUL CURRIE

sheet name

issue

drawn by

initial

sheet no.

www.onplan.com.au180 flaxton mill road, flaxton

22/03/2010 3:45:37 PM

C:\D

ocum

ents

an

d S

ettin

gs\Ian

\My D

ocum

en

ts\W

OR

K P

RO

JE

CT

S\o

npla

n\2

010

\100

3 fuchs\1

003

fuch

s 2

.rvt

r. fuchsmarch 2010

1003

perspectives

approval

im

17

issued forconstruction

purposes

revisionsA concept 08/02/10

B concept revision 16/02/10

C preliminary 22/02/10

D approval 22/03/10

onplan