Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8...

30
IEEE NGBASE-T SG November 2012 1 Category 8 Cabling Demonstration Paul Kish - Belden Antoine Pelletier - Intertek (ETL) Wayne Larsen – Commscope Theodore Brillhart – Fluke Networks

Transcript of Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8...

Page 1: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 1

Category 8 Cabling Demonstration

Paul Kish - BeldenAntoine Pelletier - Intertek (ETL)Wayne Larsen – Commscope

Theodore Brillhart – Fluke Networks

Page 2: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 2

• Contributors– Paul Kish, Belden– Antoine Pelletier, Intertek (ETL)– Wayne Larsen, Commscope– Richard Mei, Commscope– Theodore Brillhart, Fluke

Networks

• Supporters– George Zimmerman, CME

Consulting (Commscope)– Sterling Vaden, OCC– Arvind Patel, Psiber– Harshang Pandya, Psiber– Shadi AbuGhazaleh, Hubbell – Andrew Jimenez, Anixter– Tim West, Superior Essex

Page 3: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 3

Category 8 Cabling Demonstration

• This contribution is being made to show the technical feasibility of a cabling system as follows:– Two RJ-45 connectors– Balanced twisted-pair cables with the traditional four pairs– Transmission performance per TIA category 8 draft standard 0.5

• It is expected that the study group will use the technical feasibility of the cabling system to further develop technical feasibility of 40G transmission.

• Broad market potential is supported by the use of the 8-pin modular (commonly known as RJ-45) connector.

• Compatibility, for auto-negotiation, is facilitated by the use of the RJ-45 connector, that is currently defined for lower speed Ethernet applications.

Page 4: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

Category 8 Cable Development Process

• Starts with a design concept• Known design parameters such as R, G, L, and C are used to size

the construction for targeted transmission performance• Known empirical design parameters such as materials and twist

lengths are selected• Prototypes are made to explore design options and the transmission

performance is compared with the expected results for all parameters

• Several iterations are needed to refine the design until the desired results are achieved

• The results presented here are not a final iteration and furtherimprovements are anticipated

IEEE NGBASE-T SG November 2012 4

Page 5: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

Test SummaryCategory 8 F/UTP cable

•F/UTP Cable uses outer shield but does not have individually shielded pairs•Cable is round with a diameter less than 0.300” (<7.62 mm)•Good progress has been made to establish smooth transmission performance up to 2000 MHz•The NEXT spike at 200/250MHz is a known and understood cable design parameter that will be addressed in the next prototype iteration•The low frequency RL margin is known to be related to impedance centering. This prototype was slightly above 100 Ohms. The next prototype will be adjusted.•The high frequency IL roughness is due to known process parameters that will be addressed in future prototypes

IEEE NGBASE-T SG November 2012 5

Category 8 Prototype Cable Performancemeasured to 2000 MHz (50 meter length)

Page 6: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

Category 8 Connector Development Process

• Starts with a design concept• Simulation software is used to determine the transmission

performance of a “plug-jack” connection modeled as a cascaded network of 3D coupled transmission line sections

• A prototype is made and the transmission performance compared with the simulation results for all parameters

• Several iterations are needed to refine the design until the desired results are achieved

• The results presented here are for a second iteration. It is not yet the final design

IEEE NGBASE-T SG November 2012 6

Page 7: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

Test SummaryCategory 8 modular (RJ45)

connecting hardware

Backward compatibility for a mated plug-jack connection

In addition to measuring a mated Category 8 plug-jack connection, we also measured the performance of a Category 8 plug with five different vendors Category 6A jacks. The results are shown below

IEEE NGBASE-T SG November 2012 7

Category 8 Connector Performancemeasured to 2000 MHz

Page 8: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 8

Description of the independent 3rd

party testing• Third party test laboratories follow the

industry standards• The cabling test and measurement

standards have significantly evolved allowing accurate and reliable testing up to 2000 MHz

• The third party test laboratories offer independent performance verification of products (example: ETL Verified mark shown on this slide)

Page 9: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

Test Configuration

IEEE NGBASE-T SG November 2012 9

Page 10: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

Baseline Measurements

The baseline measurements were performed using the SMA adapter board with the “keychain DMCM load artifact” plugged into the socket, see picture below.

The baseline NEXT and RL measurements shown on the Right Hand Side are plotted after de-embedding the SMA adapter board

IEEE NGBASE-T SG November 2012 10

NEXT & RL Baseline measured to 2 GHz

Page 11: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 11

Test report number 100948530CRT-001aTIA-568-C.2-1, Draft 0.5

Permanent link, 40 meters

• Standard used: PN-568-C.2-1 (Draft 0.5, Dated October 16, 2012); to be published as ANSI/TIA-568-C.2-1• Tests performed: Insertion Loss, Return Loss, NEXT, PSNEXT, ACRF, PSACRF, Delay, Delay Skew• Test configuration: 2-Connector permanent link

• Test equipment used: 4-Port Network Analyzer, Agilent model number E5071C (serial number MY46214986), calibrated by Agilent on October 1, 2012 and by the user before the test with an ECal module

• Test dates: November 1-2, 2012• Test report revision history:

4-Pair F/UTP Cable2

RJ45 Connector1

DescriptionComponent ID

November 2, 2012Original documentFirst issue

DateDescriptionIssue

Page 12: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 12

Test report number 100948530CRT-001aTIA-568-C.2-1, Draft 0.5

Permanent link, 40 meters

Insertion Loss

0

5

10

15

20

25

30

35

40

45

50

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Frequency (MHz)

IL (d

B)

45123678Limit (40 m)

Page 13: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 13

Test report number 100948530CRT-001aTIA-568-C.2-1, Draft 0.5

Permanent link, 40 meters

Return Loss

0

10

20

30

40

50

60

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Frequency (MHz)

RL

(dB

)

45 (Near)12 (Near)36 (Near)78 (Near)45 (Far)12 (Far)36 (Far)78 (Far)Limit

Page 14: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 14

Test report number 100948530CRT-001aTIA-568-C.2-1, Draft 0.5

Permanent link, 40 meters

Near-End Crosstalk

0

10

20

30

40

50

60

70

80

90

100

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Frequency (MHz)

NEX

T (d

B)

45-12 (Near)45-36 (Near)45-78 (Near)12-36 (Near)12-78 (Near)36-78 (Near)45-12 (Far)45-36 (Far)45-78 (Far)12-36 (Far)12-78 (Far)36-78 (Far)Limit

Page 15: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 15

Test report number 100948530CRT-001aTIA-568-C.2-1, Draft 0.5

Permanent link, 40 meters

Power Sum NEXT

0

10

20

30

40

50

60

70

80

90

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Frequency (MHz)

PSN

EXT

(dB

)

45 (Near)12 (Near)36 (Near)78 (Near)45 (Far)12 (Far)36 (Far)78 (Far)Limit

Page 16: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 16

Test report number 100948530CRT-001aTIA-568-C.2-1, Draft 0.5

Permanent link, 40 meters

ACRF

0

10

20

30

40

50

60

70

80

90

100

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Frequency (MHz)

AC

RF

(dB

)

45-1245-3645-7812-4512-3612-7836-4536-1236-7878-4578-1278-36Limit

Page 17: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 17

Test report number 100948530CRT-001aTIA-568-C.2-1, Draft 0.5

Permanent link, 40 meters

PSACRF

0

10

20

30

40

50

60

70

80

90

100

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Frequency (MHz)

PSA

CR

F (d

B)

45123678Limit

Page 18: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 18

Test report number 100948530CRT-001aTIA-568-C.2-1, Draft 0.5

Permanent link, 40 meters

Propagation Delay

0

50

100

150

200

250

300

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Frequency (MHz)

Del

ay (n

s) 45123678Limit

Page 19: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 19

Test report number 100948530CRT-001aTIA-568-C.2-1, Draft 0.5

Permanent link, 40 meters

Propagation Delay Skew

0

5

10

15

20

25

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Frequency (MHz)

Skew

(ns)

4 PairsLimit

Page 20: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 20

Test report number 100948530CRT-001bTIA-568-C.2-1, Draft 0.5

Permanent link, 5 meters

• Standard used: PN-568-C.2-1 (Draft 0.5, Dated October 16, 2012); to be published as ANSI/TIA-568-C.2-1• Tests performed: Insertion Loss, Return Loss, NEXT, PSNEXT, ACRF, PSACRF, Delay, Delay Skew• Test configuration: 2-Connector permanent link

• Test equipment used: 4-Port Network Analyzer, Agilent model number E5071C (serial number MY46214986), calibrated by Agilent on October 1, 2012 and by the user before the test with an ECal module

• Test dates: November 1-2, 2012• Test report revision history:

4-Pair F/UTP Cable2

RJ45 Connector1

DescriptionComponent ID

November 2, 2012Original documentFirst issue

DateDescriptionIssue

Page 21: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 21

Test report number 100948530CRT-001bTIA-568-C.2-1, Draft 0.5

Permanent link, 5 meters

Insertion Loss

0

10

20

30

40

50

60

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Frequency (MHz)

IL (d

B)

45123678Limit (40 m)

Page 22: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 22

Test report number 100948530CRT-001bTIA-568-C.2-1, Draft 0.5

Permanent link, 5 meters

Return Loss

0

10

20

30

40

50

60

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Frequency (MHz)

RL

(dB

)

45 (Near)12 (Near)36 (Near)78 (Near)45 (Far)12 (Far)36 (Far)78 (Far)Limit

Page 23: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 23

Test report number 100948530CRT-001bTIA-568-C.2-1, Draft 0.5

Permanent link, 5 meters

Near-End Crosstalk

0

10

20

30

40

50

60

70

80

90

100

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Frequency (MHz)

NEX

T (d

B)

45-12 (Near)45-36 (Near)45-78 (Near)12-36 (Near)12-78 (Near)36-78 (Near)45-12 (Far)45-36 (Far)45-78 (Far)12-36 (Far)12-78 (Far)36-78 (Far)Limit

Page 24: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 24

Test report number 100948530CRT-001bTIA-568-C.2-1, Draft 0.5

Permanent link, 5 meters

Power Sum NEXT

0

10

20

30

40

50

60

70

80

90

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Frequency (MHz)

PSN

EXT

(dB

)

45 (Near)12 (Near)36 (Near)78 (Near)45 (Far)12 (Far)36 (Far)78 (Far)Limit

Page 25: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 25

Test report number 100948530CRT-001bTIA-568-C.2-1, Draft 0.5

Permanent link, 5 meters

ACRF

0

10

20

30

40

50

60

70

80

90

100

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Frequency (MHz)

AC

RF

(dB

)

45-1245-3645-7812-4512-3612-7836-4536-1236-7878-4578-1278-36Limit

Page 26: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 26

Test report number 100948530CRT-001bTIA-568-C.2-1, Draft 0.5

Permanent link, 5 meters

PSACRF

0

10

20

30

40

50

60

70

80

90

100

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Frequency (MHz)

PSA

CR

F (d

B)

45123678Limit

Page 27: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 27

Test report number 100948530CRT-001bTIA-568-C.2-1, Draft 0.5

Permanent link, 5 meters

Propagation Delay

0

50

100

150

200

250

300

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Frequency (MHz)

Del

ay (n

s) 45123678Limit

Page 28: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 28

Test report number 100948530CRT-001bTIA-568-C.2-1, Draft 0.5

Permanent link, 5 meters

Propagation Delay Skew

0

5

10

15

20

25

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Frequency (MHz)

Skew

(ns)

4 PairsLimit

Page 29: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 29

Verification Established• This demonstration shows that short and long permanent links using multi-

vendor components can meet the Category 8 requirements, including:– Shielded solutions free from alien crosstalk or EMI issues– Improved RJ-45 equipment connector:

• Smooth performance extended to 2000 MHz• Backward compatible to legacy RJ-45• Suitable for auto-negotiation

– Cable design extended to 2000 MHz without insertion loss dropouts or performance spikes

– Demonstrates compatibility and interoperability between two different manufacturers that will be compliant to component specifications in TIA Category 8 draft 0.5.

• It is feasible to make components that meet the requirements in the draft Category 8 Standard

• Modeling to add these components into links and channels has been verified by measurements

• The measured results support the model data and are confirmed byindependent third party testing

Page 30: Category 8 Cabling Demonstration - IEEE · PDF fileIEEE NGBASE-T SG November 2012 3 Category 8 Cabling Demonstration • This contribution is being made to show the technical feasibility

IEEE NGBASE-T SG November 2012 30

Conclusions• Technical feasibility is supported by the transmission performance data.• Broad market potential and compatibility are supported by the use of the

common RJ-45 connector.• Further information, including the measured data, is available in the backup

material.