CATALOGUE - Tecumseh Products · 2019-06-13 · human values. Diversity and complementarity are...
Transcript of CATALOGUE - Tecumseh Products · 2019-06-13 · human values. Diversity and complementarity are...
CATALOGUECONDENSING UNITSEuropean range 50Hz
C O O L I N G F O R A B E T T E R T O M O R R O W T M
03
Tecumseh Europe has been established for more than 85 years as a major player in commercial refrigeration, combining product expertise and commitment to its customers.Our reputation as a key player in the market is based on the simple principles driving our business: understanding our customers' issues and meeting their needs. It is thanks to the trust placed in us by each of our customers that we can continue to innovate and offer appropriate solutions.Rising to the challenges currently facing our industry, combining professional expertise and passion, the Tecumseh teams are fully mobilised and at your side.
A WORD FROM THE DIRECTOR
François BouillotManaging Director
04
INTRODUCTION
SILENSYS®
SILENSYS® INVERTER
TOOLSTABL
E OF
CON
TENT
S04
TRADITIONAL CONDENSING UNITS
WINTSYS®
RACK TRIO QUATTROINFINEE®
05
SILENSYS®
SILENSYS® INVERTER
Tecumseh, at its customers' side ................................................................ 08The Tecumseh laboratories, guaranteeing performance .................................. 12The environmental transition ...................................................................... 14Focus on liquid refrigerants with glide ........................................................... 15The widest range of products on the market .................................................... 16Nomenclature ............................................................................................. 18
47
57
69
0705
LBP (Low Back Pressure) ........................................................................... 22MHBP (Medium High Back Pressure) ......................................................... 26Dimensions ........................................................................................... 34Application windows .............................................................................. 36
Tools ................................................................................................... 70
21
39
63
LBP (Low Back Pressure) .......................................................................... 40MHBP (Medium High Back Pressure) ......................................................... 41Dimensions ........................................................................................... 43Application windows .............................................................................. 44
LBP (Low Back Pressure) ........................................................................... 48MHBP (Medium High Back Pressure) ......................................................... 50Dimensions ........................................................................................... 53Application windows .............................................................................. 54
MHBP (Medium High Back Pressure) ......................................................... 58Dimensions ........................................................................................... 60Application windows .............................................................................. 61
Rack Trio Quattro ................................................................................... 64Infinee® ................................................................................................ 66
06 INTRODUCTION
TECUMSEH, AT ITS CUSTOMERS' SIDE .............................................08►An international player►A local presence►Over 80 years of expertise ►Integrity – Excellence – Passion – Team Spirit – Respect
THE TECUMSEH LABORATORIES, GUARANTEEING PERFORMANCE ...12►The Tecumseh laboratories ►Certified products
THE ENVIRONMENTAL TRANSITION ...............................................14
FOCUS ON LIQUID REFRIGERANTS WITH GLIDE .............................15
THE WIDEST RANGE OF PRODUCTS ON THE MARKET .....................16►From the simplest to the most extensively equipped
NOMENCLATURE ...........................................................................18►Explanation of the designation of the model names►Explanation of the codes and voltage ranges►The serial label
07
INTRODUCTION
07
08 INTRODUCTION
AN INTERNATIONALPLAYER
The mission of Tecumseh Europe, subsidiary of American Group Tecumseh Products Company, is to make life better through cooling. Tecumseh improves everyday life by offering a full range of compressors and condensing units. These products are intended for customers' food preservation and thermal comfort applications.
Tecumseh aims to become the expert in innovative, sustainable and safe cooling solutions for commercial use.
Aiming for global success and exceeding its results, Tecumseh is committed to participating in the success of its customers by offering innovative, certified and environmentally-friendly products.
. AT ITS CUSTOMERS' S IDE
TECUMSEH AROUND THE WORLD
9FACTORIESEMPLOYEES
09
36COUNTRIES IN EUROPE
18COUNTRIES IN AFRICA
AND MIDDLE-EAST
3FACTORIES IN FRANCE
850EMPLOYEES
2LABORATORIES
Commercialpresence
ATITS
CUSTOMERS'SIDE
CESSIEU (38)
A LOCALPRESENCE
Tecumseh's largest geographic area, Tecumseh Europe, covers the whole of Europe and Africa. The headquarters of this subsidiary is located in the Auvergne-Rhône-Alpes region of France, in the heart of Europe. In order to be as close as possible to its customers, the company has a reinforced commercial presence across the entire area, with offices in Germany, Spain, Italy, Poland, the United Kingdom and Morocco, and European coverage extending as far as Russia.
LA MURE (38)
OUR PLANTS IN FRANCE
BARENTIN (76)
10 INTRODUCTION
MORE THAN80 YEARS OF EXPERTISE
. AT ITS CUSTOMERS' S IDE
2009
20172018
2011
2012
2013
2014
1934
1937
195419601962
1977
1997
2000
2003
2019
Creation of the Tecumseh Products Company
Developmentof the first hermetic compressor
in the United States
Creation of "Hermetic Unit®"
in France
Opening of the plantsin Barentin
and then Cessieu
Openingof the La Mure plant
The Hermetic Unit®becomes Tecumseh Europe
Launch of the1st generation of SILENSYS®
Launch of the 1st generationof pre-equipped condensing units
Launch ofthe SILENSYS® Inverter
Launch of the AJ2
Launchof the WINTSYS®
(1st version)
Launch of the new generationof SILENSYS® and of the AE2
Extensionof the AG range
Launch of the new generation of WINTSYS®
and of the TC
Launch of INFINEE®
Launch of the AW
11
INTEGRITY - EXCELLENCEPASSION - TEAM SPIRIT - RESPECT
2009
20172018
2011
2012
2013
2014
1934
1937
195419601962
1977
1997
2000
2003
2019
Launch ofthe SILENSYS® Inverter
Extensionof the AG range
Listed in the Tecumseh Products Company's DNA, our values are expressed in the daily lives of all teams around the world by guiding our actions and behaviors.
If for 85 years, we have been dedicated to a single profession, commercial refrigeration is primarily for passion. Passion for what refrigeration brings to individuals: serenity, pleasure. Passion also for a profession concerning a precision industry, with the desire to design new solutions and deploy the enthusiasm to create them. Passion drives each of our 5,000 employees every day.
Excellence is also a founding value. By engaging with our customers, suppliers and partners, we always looking for perfection. The highest degree of quality applies everywhere: design of compressors and condensing units, search for safety, understanding customer needs. We share this desire to go beyond ourselves to offer the best to our customers.
Teamwork is a value that has always been rooted in our practices and the involvement of our employees. It is the union of all our talents that shapes this spirit: the skills of one team with the expertise of others and thus contribute to our success. This team spirit gives full meaning to the relationship we build with our customers, partners and suppliers.
Integrity is a value based on the principle of consistency. We carry ourselves in a way where integrity is visible through our actions, words, decisions, methods and outcomes. We lead with honesty and authenticity and move forward with intentionality and thought. We are who we are always, regardless of the situation or the environment we are in. We recognize our impact on the world and those around us and are actively focused on the development of character. Most importantly, we lead by example and draw those around us to be on the same journey.
Finally, respect is embedded in our culture, animated since its inception by deep human values. Diversity and complementarity are considered as a wealth, a source of dynamism and creativity. Beyond an attitude of listening, respect is about fulfilling commitments in the long term. Respect is an integration of internal social responsibility as well as environmental responsibility.
12 INTRODUCTION
Reliability and efficiency are the key words for all Tecumseh products.
Our laboratories are unique tools, carrying out a range of R&D tests, certifications and measure-ments specific to the condensing units and compressors. In this way, Tecumseh guarantees custom-ers the optimum operation and service life for its products.
THE TECUMSEHLABORATORIES
Calorimetricperformance:compressors and condensing units
100%MASTERED
INNOVATION
Acousticmeasurements:sound power, pressure level, vibration
Calibration and maintenance of the measuring equipment
Safety:electrical and mechanical
Metrology:measurements of mechanical parts, surface conditions, geometries
Chemistry: oil analyses, components, metals, compatibility
Tests on customerapplications: energy efficiency, new refrigerants
. THE TECUMSEH LABORATORIES, GUARANTEEING PERFORMANCE
13
29 TEST CHAMBERS AND 4 MOTOR TEST BENCHES
17 calorimeters
7 climaticrooms
3 endurancerooms
2 acousticrooms
CERTIFIEDPRODUCTS
Tecumseh wishes to provide its customers with innovative products and services of excellent quality and high added value. So, it favours product certification.
QUALITY AND ENVIRONMENTThe two Management systems run by Tecumseh testify to its day-to-day commitment and its ability to maintain and advance its certifications.
Audited every year, the laboratory is accredited for 2 test programmes:►Refrigerating performance of compressors and condensing units►Electrical and mechanical safety
The laboratory guarantees the accuracy of the measurements provided and the conformity of the products to installers, specifiers and users.
1200 measuringsensors
50 engineersand technicians
2500 productstested by year
800 test reportsper year
The Cessieu plant has received ISO 14001 certification. This certification attests to Tecumseh's commitment to environmental aspects.
An active member of ASERCOM for more than 20 years, Tecumseh Europe submits all its products to the association certification procedures.
The performance and quality of Tecumseh products are measured in the laboratory in accordance with the procedures and conditions defined by standards EN 13771-1 and -2 and declared in accordance with EN 13215 and EN 12900. They are also compared to the competing products certified by ASERCOM.
This certification fulfils the needs and expectations of our customers by offering products that meet the requirements of the European regulation.
ASERCOM
ISO 17025 by the COFRAC
ISO 9001, version 2015: Quality Management System
ISO 14001, version 2015: Environmental Management System
Accreditation n°1-6140. Scope available on
www.cofrac.fr
14 INTRODUCTION
The condensing units offered by Tecumseh meet the requirements of the European directives:
►The requirements of the European Ecodesign directive 2009/125/EC relating to electrical devices affecting the level of energy efficiency of the condensing units through EU Regulation 2015/1095-Lot 1.
►The application of the European F-Gas directive 517/2014 is gradually restricting the use of Hydrofluorocarbon (HFC) liquid refrigerants over time, with a high level of reduction of the marketing of new products imposed in 2018 and 2021.
THE ADVANTAGES OF THE TECUMSEH RANGE, YOUR PARTNER OF CHOICE:
► Condensing units with low power consumption ► An approved range with liquid refrigerants A1, A2L and A3► A wide and varied range
A CHOICE OF LOW GWP FLUIDS
Since January 2018, there is a range of hermetic condensing units compatible with fluids having a GWP (Global Warming Potential) which are 50 to 60% lower than the fluids that they replace, those available are:
►R452A/R404A for low pressure and medium high pressure►R134a/R513A for medium high pressure
THE ENVIRONMENTALTRANSITION
. THE ENVIRONMENTAL TRANSIT ION AND LIQUID REFRIGERANTS
2015 - 2017 2018 - 2020 2021 - 2023APPLICATION
POSITIVE TEMPERATURE
NEGATIVETEMPERATURE
ALLAPPLICATIONS
R290
R290 / R600a
CO2
POSITIVE TEMPERATURE
POSITIVETEMPERATURE
NEGATIVETEMPERATURE
R134a R134a / R513A R1234yfR134a / R513A R1234yf
R404A / R452A
R452A / R448A/R449A
R452A / R448A / R449A
R454C / R455A... R454C / R455A...
Tecumseh Company property 2018
DEADLINES F-GAS
2021 - 2023 2030...
ROADMAP OF PRODUCT LAUNCHES IN LINE WITH THE F-GAS CUT-OFF DATES
By 2030, the F-Gas directive will limit the availability of HFCs, all fluids and all applications combined to 21%.
Between 2020 and 2022, additional measures will prohibit the use of HFCs with high GWP for certain applications such as fixed refrigeration equipment or mobile air conditioning.
Eventually, in order to limit the proliferation of alternatives, the choices of liquid refrigerants for commercial refrigeration will be made according to market requirements, which tend to synthetic fluids or natural fluids with GWP lower than 150.
THE LIQUID REFRIGERANT ROADMAP
15
FOCUS ONLIQUID REFRIGERANTS WITH GLIDE
TEMPERATURE OF THE LIQUID REFRIGERANTS DURING THE CHANGE OF STATE IN EXCHANGERS
►Definition: The azeotropic mixtures (such as R404A) have a similar behaviour to the pure fluids (such as R134a). They condense and evaporate at an almost constant temperature.
The R452A, R449A and R448A refrigerants are non-azeotropic mixtures, also called "zeotropic mixtures". They show significant variation in temperature during the change of state at constant pressure. This temperature variation is called glide.
Therefore, a mean temperature (Tm) is defined to present the performance of systems operating with these zeotropic liquid refrigerants, and to compare them to the pure fluids.
Subcooling is determined from the Bubble Temperature.Superheating is determined from the Dew Point Temperature.Glide is defined by the difference between the Dew Point Temperature and the Bubble Temperature at constant pressure.
Mean condensing temperature:
Tc_m =((Dew point Tc + Bubble Tc))
The mean evaporation temperature 'Tm' is defined by the relationship:
To_m = ((Evaporator inlet T + Dew point To))
►Diagram:
2
2
Pressure
Enthalpy kJ/kg
Cond P
Isobar
Isotemperature
Liquid T° Bubble Tc Mean Tc Dew point Tc
Dew point ToMid ToEvaporatorinlet T
Evap. P
16 INTRODUCTION
FROM THE SIMPLEST… . THE WIDEST RANGE OF PRODUCTS ON THE MARKET
►A stretch of cooling capacity to suit all requirements with high efficiency
►Compactness for ease of integration within applications
►Recognised reliability
OPTION:►Liquid line with full pre-equipped units
-30°C evap.: from 0.2 to 5.9 kW-10°C evap.: from 0.1 to 17 kW
w COOLING CAPACITYACCORDING TO EN13215 and SH 10 K
TRADITIONAL CONDENSING UNITS
WINTSYS®
PRE-EQUIPPED AND EASY TO INSTALL
►A competitive plug & play unit for demanding outdoor solutions
►Easy to install
-30°C evap.: from 0.4 to 1.6 kW-10°C evap.: from 0.7 to 4.4 kW
w COOLING CAPACITYACCORDING TO EN13215 and SH 10 K
APPLICATIONS
17
PLUG & PLAY CAPACITY VARIATIONTHE ACOUSTIC REFERENCE ON THE MARKET
… TO THE MOST EXTENSIVELY EQUIPPED
►An acoustic solution for urban environments
►High energy efficiency without compromise on the components
►Enhanced electrical safety and complete electrical equipment
-30°C evap.: from 0.5 to 6.1 kW-10°C evap.: from 0.7 to 17 kW
w COOLING CAPACITYACCORDING TO EN13215 and SH 10 K
SILENSYS® SILENSYS® INVERTER
►Continuity of cooling the system assured by its dual control
►Variable capacity to suit the following types of installation: - multi-station - with extensive variation of heat load
►Advantages: - complete wiring - factory configuration - Tecumseh standard compressor
-10°C evap.: from 0.7 to 17.3 kW
w COOLING CAPACITYACCORDING TO EN13215 and SH 10 K
18 INTRODUCTION
EXPLANATIONOF THE MODEL NAMES DESCRIPTION
T AJ N T 4 5 19 Z H R
ConnectionLetter absence = with valve or to be solderedR = with liquid reservoir
H = High suction pressure (-15°C to + 15°C)B = Low pressure (-40°C to -10°C)M = Medium and high suction pressure (-25°C to +15°C)
U = Refrigerant R290Y = Refrigerant R513A – R134aZ = Refrigerant R452A – R404A
Corresponds to the first digits of the cooling capacity expressed in BTU/h at 60 Hz in accordance with the given rating point conditions.Example: 19 preceded by the digit 5 means: 19,000 BTU/h.
Applications2 = Low back pressure. Motor with high starting torque.3 = High back pressure. Motor with high normal starting torque.4 = High back pressure. Motor with high starting torque.9 = Medium and high back pressure. Motor with high starting torque.
Number of figures making up the cooling capacity. Example: 19,000 BTU/h.
Condensing unitsT = HAT (High Ambient Temperature)
Condensing unitsN = New model AJCompressorsThe letter D designates compressors or units mounted as a "duo".The letter TR designates compressors mounted as a "trio".
Families: THB-AE-AJ-FH-AW-AG-HGA-RGA-SH.
Without letter = single-phase low torqueC = single-phase high torqueT = three-phase
COM
PRES
SOR
DESI
GN
ATIO
N
CON
DEN
SIN
G U
NIT
DES
IGN
ATIO
N
Compressors or units supplied with oil under nitrogen pressure with suspension clearances. Adjustable valves supplied not mounted.
. NOMENCLATURE
19
EXPLANATIONOF THE CODES AND VOLTAGE RANGES
REFERENCE DESIGNATION
A Voltage
B Frequency
C Number of phases
D Nominal current
E Production ordernumber
F Liquid refrigerant
G Designation of the unit
H Serial number
SERIALLABEL
CODE FZ XC KZ TZ - XG
PHASE 1~ 1~ 3~ 3~
NOMINAL 50 Hz 220-240 V 220-240 V 220 V 400 V
VOLTAGE RANGE 50 Hz 198-253 V 198-264 V 180-253 V 340-440 V
20 TRADIT IONAL CONDENSING UNITS
TRADITIONAL CONDENSING UNITS
EQUIPMENTELECTRICAL COMPONENTS► AC fans (AJ platform: EC fans), compatible with variable speed►IP 44 electrical box►Casing heater (AW, FH, AG)►Compressor electrical protection
CIRCUIT► Adjustable HP/LP pressure switch with automatic resetting on AW,
FH and AG►Condenser up to 46°C►Liquid reservoir
INSTALLATION/MAINTENANCE►Isolation valves, charge points and vacuum drawing
PRE-EQUIPPED TRADITIONAL CONDENSING UNITS►Reduction in installation time recognised by installers (between half an hour and one hour)►Increased safety with all components checked
ACCESSORY: fan speed control kit
fittingsto be soldered
(CAJN/TAJN units)
sight glass dryer filter HP/LP pressure switchwith manual or automatic
resetting
21
TRADITIONALCONDENSING
UNITS
21
22 TRADIT IONAL CONDENSING UNITS
MODEL NUMBER
REFRIGERATION OUTPUT43 ° amb., 10K superheating, 3K subcooling, Mid/Mid
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -35°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximum current
according to voltage code
-35° -30° -25° -20° -15° -10° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
CAJT2432ZBR 243 359 497 656 839 1046 397 0.83 39 1130 1.50 1/2" 1/4" 34/36 M300 6.5 na
CAJT/TAJT2446ZBR 384 538 711 901 1110 1343 625 0.96 40 1130 1.50 1/2" 3/8" 36/38 M300 8.8 3.3
CAJT/TAJT2464ZBR 545 745 980 1255 1571 1931 844 0.93 45 2464 1.50 5/8" 3/8" 47/51 M350 10.7 3.8
Special condensing units*
MODEL NUMBER
REFRIGERATION OUTPUT32 ° amb., 10K superheating, 3K subcooling, Mid/Mid
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -35°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximum current
according to voltage code
-35° -30° -25° -20° -15° -10° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
AET2415ZBR 159 209 267 331 402 479 184 0.80 28 340 0.75 3/8" 1/4" 20/21 M200 3.2 na
AET2420ZBR 201 268 345 434 533 643 232 0.88 27 410 0.75 3/8" 1/4" 20/21 M200 4.6 na
CAJ/TAJN2428ZBR 245 334 440 562 703 863 283 0.80 26 550 1.50 1/2" 1/4" 30/32 M250 5.3 2.2
AET2425ZBR 266 354 454 568 695 836 309 0.86 34 500 0.75 3/8" 1/4" 26/27 M250 4.6 na
CAJN2432ZBR 295 401 523 664 823 1003 342 0.86 28 550 1.50 1/2" 1/4" 30/32 M250 6.0 na
CAJN2440ZBR 416 573 758 970 1213 1489 473 0.98 27 900 1.50 1/2" 3/8" 32/34 M300 5.8 na
CAJ/TAJN2446ZBR 521 698 901 1129 1382 1659 600 1.04 31 900 2.35 1/2" 3/8" 33/35 M300 8.4 3.2
CAJ/TAJN2464ZBR 662 868 1103 1366 1657 1978 771 0.95 33 900 2.35 5/8" 3/8" 34/36 M300 10.2 4.0
FH/TFHT2480ZBR 1024 1375 1773 2219 2717 3273 1164 1.03 43 1750 1.50 5/8" 3/8" 57/61 M350 16.5 6.9
FH/TFHT2511ZBR 1279 1718 2217 2780 3423 4169 1465 1.06 46 1750 1.50 5/8" 3/8" 57/61 M350 24.6 7.8
TAGT2513ZBR 1472 2162 2959 3858 4856 5957 1631 0.95 51 3900 2.35 7/8" 3/8" 73/87 M420 na 9.3
TAGT2516ZBR 1773 2543 3434 4446 5586 6870 1992 1.09 50 3300 2.35 7/8" 3/8" 79/93 M420 na 10.2
TAGT2519ZBR 2066 2945 3968 5137 6464 7968 2317 1.60* 51 2500 3.90 7/8" 3/8" 85/105 M450 na 11.7
TAGT2522ZBR 2345 3271 4346 5573 6964 8540 2650 1.62* 51 2500 3.90 1"1/8 3/8" 86/100 M450 na 14.2
TAGT2525ZBR 2598 3597 4728 5993 7401 8974 2940 1.60* 54 2500 3.90 1"1/8 1/2" 87/101 M450 na 14.1
TAGDT2532ZBR 3586 5136 6909 8897 11100 13547 4020 1.63* 53 7000 6.00 1"1/8 1/2" 154/184 B420 na 21.3
TAGDT2538ZBR 4111 5738 7598 9687 12012 14612 4656 1.65* 53 7000 6.00 1"1/8 1/2" 154/184 B420 na 21.3
TAGDT2544ZBR 5010 6864 8918 11268 13932 16974 5707 1.65* 54 7000 6.00 1"1/8 1/2" 161/191 B420 na 29.0
TAGDT2550ZBR 5069 6982 9290 11913 14792 17834 5811 1.69* 57 7000 6.00 1"1/8 1/2" 161/191 B420 na 29.0
SHT2529ZBR-YZ 3603 4772 6063 7471 8997 10654 3729 1.92* na 7600 3.90 1"1/8 1/2" 132/162 B420 na 14.0c
SHT2534ZBR-YZ 4479 5849 7376 9053 10872 12834 4667 1.88* na 7000 3.90 1"3/8 5/8" 134/164 B420 na 16.3c
SHT2542ZBR-YZ 5332 6789 8422 10230 12210 14361 5637 1.86* na 7000 6.00 1"3/8 5/8" 134/164 B420 na 16.7c
SHT2552ZBR-YZ 6694 8584 10715 13089 15703 18555 7002 2.04* na 8270 6.00 1"3/8 5/8" 151/181 B420 na 21.7c
SHT2568ZBR-MZ 8666 10913 13349 16005 18901 22058 9207 1.99* na 7600 9.50 1"3/8 5/8" 199/229 B500 na 27.2d
SHT2575ZBR-MZ 10142 13099 16380 20026 24065 28513 10551 2.13* na 14600 9.50 1"5/8 5/8" 221/251 B500 na 33.2d
Statement of the seasonal COP / na: not applicable/ a voltage code XC, b voltage code XG, c voltage code YZ, d voltage code MZ
Traditional condensing units
R452A
na: not applicable
LBP
* Special: Tropical units formerly called HTA.
23
LBP
R404A
MODEL NUMBER
REFRIGERATION OUTPUT43 ° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -35°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-35° -30° -25° -20° -15° -10° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
CAJT2432ZBR 268 381 514 668 843 1039 465 0.95 38 1130 1.50 1/2" 1/4" 34/36 M300 6.5 na
CAJ/TAJT2446ZBR 396 543 708 890 1087 1298 701 1.01 40 1130 1.50 1/2" 3/8" 36/38 M300 8.8 3.3
CAJ/TAJT2464ZBR 557 755 985 1250 1548 1882 933 0.96 45 2464 1.50 5/8" 3/8" 47/51 M350 10.7 3.8
Special condensing units*
MODEL NUMBER
REFRIGERATION OUTPUT32 ° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -35°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-35° -30° -25° -20° -15° -10° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
AET2415ZBR 160 208 263 323 389 459 202 0.83 28 340 0.75 3/8" 1/4" 20/21 M200 3.2 na
AET2420ZBR 206 271 347 432 526 628 259 0.92 27 410 0.75 3/8" 1/4" 20/21 M200 4.6 na
CAJ/TAJN2428ZBR 250 339 442 561 694 844 315 0.82 26 550 1.50 1/2" 1/4" 30/31 M250 5.3 2.2
AET2425ZBR 273 359 456 565 685 817 344 0.90 34 500 0.75 3/8" 1/4" 26/27 M250 4.6 na
HGA2426ZBR 299 385 482 597 729 880 375 1.07 37 1000 0.75 3/8" 1/4" 21/28 B200 3.8 na
CAJN2432ZBR 309 415 536 673 824 991 392 0.95 28 550 1.50 1/2" 1/4" 30/31 M250 6.0 na
HGA2432ZBR 367 467 578 705 848 1011 462 1.09 35 1000 0.75 3/8" 1/4" 21/28 B200 4.6 na
HGA2436ZBR 384 492 613 750 905 1080 484 1.08 39 1000 0.75 1/2" 1/4" 22/29 B200 5.4 na
CAJN2440ZBR 425 577 756 962 1194 1453 529 1.01 27 900 1.50 1/2" 3/8" 32/33 M300 5.8 na
HGA2446ZBR 494 636 794 974 1178 1409 623 1.11 38 1000 0.75 1/2" 3/8" 26/33 B200 5.8 na
CAJ/TAJN2446ZBR 530 707 907 1129 1370 1629 665 1.04 31 900 2.35 1/2" 3/8" 33/35 M300 8.4 3.2
CAJ/TAJN2464ZBR 678 881 1109 1361 1634 1924 856 0.98 33 900 2.35 5/8" 3/8" 34/36 M300 10.2 4.0
FH/TFHT2480ZBR 1068 1424 1822 2262 2743 3267 1323 1.08 43 1750 1.50 5/8" 3/8" 57/61 M350 16.5 6.9
FH/TFHT2511ZBR 1302 1743 2236 2782 3389 4073 1629 1.09 46 1750 1.50 5/8" 3/8" 57/61 M350 24.6 7.8
TAGT2513ZBR 1482 2092 2810 3632 4550 5553 1840 0.99 51 3900 2.35 7/8" 3/8" 73/87 M420 na 9.3
TAGT2516ZBR 1906 2681 3582 4605 5746 7005 2361 1.61* 50 3900 2.35 7/8" 3/8" 79/93 M420 na 10.2
TAGT2519ZBR 2117 2978 3977 5110 6377 7784 2629 1.70* 50 2500 3.90 7/8" 3/8" 85/105 M450 na 11.7
TAGT2522ZBR 2403 3306 4353 5542 6872 8343 2990 1.70* 51 2500 3.90 1"1/8 3/8" 86/100 M450 na 14.2
TAGT2525ZBR 2631 3589 4676 5888 7220 8671 3280 1.67* 54 2500 3.90 1"1/8 1/2" 87/101 M450 na 14.1
SHT2529ZBR 3378 4452 5661 7002 8473 10075 3813 1.69* na 7600 3.90 1"1/8 1/2" 132/162 B420 na 14.0c
SHT2534ZBR 4197 5481 6926 8527 10275 12169 4753 1.69* na 7000 3.90 1"3/8 5/8" 134/164 B420 na 16.3c
TAGDT2532ZBR 3713 5198 6906 8825 10941 13250 4612 1.73* 53 7000 6.00 1"1/8 1/2" 154/184 B420 na 21.3
TAGDT2538ZBR 4240 5803 7599 9613 11836 14268 5283 1.74* 53 7000 6.00 1"1/8 1/2" 154/184 B420 na 21.3
TAGDT2544ZBR 4755 6390 8264 10364 12687 15241 5944 1.75* 54 7000 6.00 1"1/8 1/2" 161/191 B420 na 29.0
SHT2542ZBR 5042 6424 7978 9703 11599 13666 5741 1.70* na 7000 6.00 1"3/8 5/8" 134/164 B420 na 16.7c
TAGDT2550ZBR 5174 6903 8839 10971 13297 15835 6485 1.63* 57 7000 6.00 1"1/8 1/2" 161/191 B420 na 29
SHT2552ZBR 6387 8176 10219 12520 15076 17881 7206 1.89* na 8270 6.00 1"3/8 5/8" 151/181 B420 na 21.7c
SHT2568ZBR 8076 10176 12451 14929 17629 20579 9252 1.83* na 7600 9.50 1"3/8 5/8" 199/229 B500 na 27.2 d
SHT2575ZBR 9525 12247 15300 18727 22557 26810 10749 1.77* na 14600 9.50 1"5/8 5/8" 221/251 B500 na 33.2 d
Statement of the seasonal COP / na: not applicable / a voltage code XC, b voltage code XG, c voltage code YZ, d voltage code MZ
Traditional condensing units
na: not applicable
For information, the cooling capacity of fluids R449A and R448A: at the evaporation point To = -30°C, SH10K, apply the multiplier ratio 0.94 to the cooling capacities read with R404A.
* Special: Tropical units formerly called HTA.
24 TRADIT IONAL CONDENSING UNITS
LBP
MODEL NUMBER
REFRIGERATION OUTPUT32 ° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -35°CAco. P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximum current
according to voltage code
-35° -30° -25° -20° -15° -10° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ
AE2410UB 105 146 194 250 314 387 123 0.72 29 340 na 1/4" 1/4" 17/19 M200 2.5
AE2415UB 162 221 287 361 441 530 191 0.85 29 340 na 3/8" 1/4" 17/19 M200 3.1
AE2420UB 240 310 390 480 581 693 283 0.97 29 410 na 3/8" 1/4" 17/19 M200 3.9
Traditional condensing units
na: not applicable
R290
2525
26 TRADIT IONAL CONDENSING UNITS
MHBP
MODEL NUMBER
REFRIGERATION OUTPUT43 ° amb., 10K superheating, 3K subcooling, Mid/Mid
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximum current
according to voltage code
-25° -15° -10° -5° 0° 5° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
CAJ/TAJT9480ZMHR 430 754 948 1169 1422 1708 2393 1227 1.67 38 1130 1.50 1/2" 3/8" 37/39 M300 7.3 3.4
CAJ/TAJT9510ZMHR 550 948 1186 1458 1769 2122 2965 1538 1.72 40 1180 1.50 5/8" 3/8" 42/46 M320 9.2 3.4
CAJ/TAJT9513ZMHR 623 1156 1480 1849 2268 2743 3872 1966 1.89 45 2250 1.50 5/8" 3/8" 45/49 M350 12.0 4.3
CAJ/TAJT4517ZHR 712 1318 1648 2022 2449 2934 4103 2167 1.85 45 2250 2.35 5/8" 3/8" 48/52 M350 13.4 4.4
CAJ/TAJT4519ZHR 881 1632 2070 2566 3123 3742 5239 2752 1.73 40 1650 2.35 5/8" 3/8" 48/52 M350 15.6 6.6
Special condensing units*
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling, Mid/Mid
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximum current
according to voltage code
-25° -15° -10° -5° 0° 5° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
AET4425ZHR 154 262 329 408 499 604 857 340 1.44 31 410 0.75 3/8" 1/4" 19/21 M200 3.0 na
AET4430ZHR 189 320 398 489 592 709 981 414 1.49 29 410 0.75 3/8" 1/4" 20/21 M200 3.1 na
AET4440ZHR 259 437 544 667 808 969 1359 565 1.49 35 500 0.75 3/8" 1/4" 24/26 M250 4.1 na
AET4450ZHR --- 550 675 816 974 1151 1563 708 1.46 39 500 0.75 3/8" 1/4" 25/27 M250 5.5 na
AET4460ZHR 457 728 890 1079 1296 1543 2138 924 1.61 39 1130 0.75 3/8" 1/4" 25/27 M300 6.5 na
AET4470ZHR 523 847 1034 1248 1490 1766 2446 1077 1.61 39 1130 0.75 3/8" 1/4" 28/30 M300 5.9 na
HGA4467ZHR 511 772 928 1103 1297 1510 1997 974 2.10 38 1000 0.75 3/8" 1/4" 22/29 B200 4.0 na
HGA4480ZHR 614 932 1121 1332 1565 1820 2389 1176 2.16 35 1000 0.75 3/8" 3/8" 25/32 B200 5.7 na
HGA4492ZHR 711 1055 1259 1487 1739 2017 2655 1326 2.18 38 1000 0.75 1/2" 3/8" 26/33 B200 5.5 na
HGA4512ZHR 834 1238 1470 1721 1990 2274 2874 1562 1.98 39 1000 0.75 1/2" 3/8" 26/33 B200 7.1 na
CAJ/TAJN9480ZMHR 529 887 1098 1341 1616 1925 2648 1148 1.66 33 900 1.50 1/2" 3/8" 33/35 M300 6.9 3.2
CAJ/TAJN9510ZMHR 653 1068 1310 1586 1897 2246 3063 1380 1.64 34 900 1.50 5/8" 3/8" 33/35 M300 8.6 3.2
CAJ/TAJN9513ZMHR 768 1287 1585 1916 2278 2673 na 1675 1.70 34 900 1.50 5/8" 3/8" 34/36 M300 11.5 4.1
CAJ/TAJN4517ZHR 1000 1644 2023 2460 2955 3514 4845 2109 1.84 40 1700 2.35 5/8" 3/8" 44/48 M350 13.5 4.4
CAJ/TAJN4519ZHR 1212 2044 2520 3055 3649 4307 5835 2641 1.64 40 1700 2.35 5/8" 3/8" 44/48 M350 16.0 5.6
FH/TFHT4522ZHR 1122 2103 2692 3361 4097 4888 6526 2772 1.80 43 1650 2.35 5/8" 3/8" 55/59 M350 17.1 6.5
FH/TFHT4524ZHR 1325 2429 3088 3834 4660 5561 7558 3187 1.72 49 3900 2.35 5/8" 3/8" 63/77 M420 20.7 8.8
FH/TFHT4531ZHR 1747 3113 3895 4775 5754 6840 9353 4048 1.80 50 3670 3.90 7/8" 1/2" 69/83 M420 23.5 9.3
AWT4538ZHR 2218 3929 4905 5984 7162 8456 11556 5095 2.80* 50 3300 3.90 7/8" 1/2" 67/81 M420 27.0a 9.7b-c
TAGT4546ZHR 2349 4702 6146 7949 9572 11560 16229 6271 2.59* 55 7000 6.00 7/8" 1/2" 100/120 B420 na 15.6
TAGT4553ZHR 2714 5321 6891 8838 10558 12660 17569 7055 2.59* 54 7000 6.00 7/8" 5/8" 101/121 B420 na 16.3
TAGT4561ZHR 3219 6083 7779 9873 11698 13939 19232 7988 2.61* 55 7000 6.00 1"1/8 5/8" 101/121 B420 na 17.6
TAGT4568ZHR 3902 6953 8755 11000 12953 15391 21354 9065 2.60* 54 7000 6.00 1"1/8 5/8" 102/122 B420 na 20.1
TAGT4573ZHR 4411 7857 9877 12379 14531 17209 23545 10182 2.58* 54 6000 6.00 1"1/8 5/8" 107/127 B420 na 21.3
Statement of the seasonal COP / na: not applicable / a voltage code XC, b voltage code XG, c voltage code YZ, d voltage code MZ
Traditional condensing units
R452A
* Special: Tropical units formerly called HTA.
27
Statement of the seasonal COP / na: not applicable / a voltage code XC, b voltage code XG, c voltage code YZ, d voltage code MZ
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling, Mid/Mid
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-25° -15° -10° -5° 0° 5° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
SHT4576ZHR 5285 8488 10285 12296 14470 16803 21972 10245 2.80* na 6000 6.00 1"1/8 5/8" 138/158 B420 na 13.9c
TAGT4581ZHR 4772 8216 10228 12719 14829 17435 23592 10636 2.55* 55 6000 6.00 1"1/8 5/8" 107/127 B420 na 23.1
TAGDT4590ZHR 4639 8809 11412 14692 17644 21257 29481 11739 2.85* 57 8270 9.50 1"1/8 5/8" 175/205 B420 na 28.9
SHT4591ZHR 6567 10391 12639 15225 18088 21217 na 12518 3.05* na 8270 6.00 1"1/8 5/8" 151/181 B420 na 15.0c
TAGDT4610ZHR 5464 10107 12953 16518 19671 23520 32271 13359 2.85* 56 8270 9.50 1"1/8 5/8" 179/209 B420 na 30.3
SHT4610ZHR 7660 12292 14860 17726 20871 24379 na 14733 2.65* na 14600 9.50 1"3/8 5/8" 180/210 B500 na 20.3c
TAGDT4612ZHR 6516 11815 15088 19210 22856 27288 37121 15532 2.65* 60 14600 9.50 1"1/8 5/8" 205/239 B500 na 33.3
SHT4612ZHR 8827 14158 16956 19977 23227 26885 na 16877 2.63* na 14600 9.50 1"3/8 5/8" 180/210 B500 na 22.7d
TAGDT4614ZHR 7964 13744 17360 21957 26019 30986 42198 17962 2.72* 59 14600 12.00 1"3/8 7/8" 209/239 B500 na 38.3
TAGDT4615ZHR 8851 15470 19279 23955 27903 32842 45160 19970 2.72* 59 13000 12.00 1"3/8 7/8" 217/247 B500 na 40.7
SHT4615ZHR 10427 16310 19810 23806 28129 32666 na 19751 2.72* na 14100 12.00 1"3/8 7/8" 227/257 B500 na 25.1d
TAGDT4616ZHR 9960 17486 21721 26889 31214 36654 50433 22554 2.69* 60 13000 12.00 1"3/8 7/8" 216/246 B500 na 44.3
SHT4620ZHR 14684 22333 26401 30937 35957 41690 na 26511 2.78* na 13000 12.00 1"5/8 7/8" 234/264 B500 na 35.1d
Traditional condensing units
For information, the cooling capacity of fluids R449A and R448A: at the evaporation point To = -30°C, SH10K, apply the multiplier ratio 0.94 to the cooling capacities read with R404A.
28 TRADIT IONAL CONDENSING UNITS
MHBP
MODEL NUMBER
REFRIGERATION OUTPUT43° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-25° -15° -10° -5° 0° 5° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
CAJ/TAJT9480ZMHR 429 746 934 1143 1376 1634 2245 1299 1.69 38 1130 1.50 1/2" 3/8" 37/40 M300 7.3 3.4
CAJ/TAJT9510ZMHR 548 937 1168 1426 1711 2028 2781 1627 1.74 39 1180 1.50 5/8" 3/8" 42/41 M320 9.2 3.4
CAJ/TAJT9513ZMHR 616 1140 1454 1805 2193 2622 3633 2083 1.91 45 2250 1.50 5/8" 3/8" 45/47 M350 12.0 4.3
CAJ/TAJT4517ZHR 726 1305 1625 1979 2370 2804 3843 2292 1.87 46 2250 2.35 5/8" 3/8" 48/52 M350 13.4 4.4
CAJ/TAJT4519ZHR 938 1687 2119 2594 3112 3674 4937 3007 2 41 1350 2.35 5/8" 3/8" 48/52 M350 15.6 6.6
Special condensing units*
Traditional condensing units
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-25° -15° -10° -5° 0° 5° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
AET4425ZHR 154 258 323 398 484 581 811 359 1.46 31 410 0.75 3/8" 1/4" 19/20 M200 3.0 na
AET4430ZHR 190 315 392 479 575 682 929 437 1.50 29 410 0.75 3/8" 1/4" 19/21 M200 3.1 na
AET4440ZHR 263 432 535 652 784 930 1273 596 1.51 35 500 0.75 3/8" 1/4" 24/25 M250 4.1 na
AET4450ZHR 339 545 666 799 944 1101 1458 746 1.47 39 500 0.75 3/8" 1/4" 25/26 M250 5.5 na
AET4460ZHR 463 721 880 1059 1261 1488 2029 976 1.63 39 1130 0.75 3/8" 1/4" 25/27 M300 6.5 na
AET4470ZHR 535 840 1020 1222 1448 1700 2304 1134 1.62 39 1130 0.75 3/8" 1/4" 28/30 M300 5.9 na
HGA4467ZHR 472 723 873 1040 1228 1440 1952 973 1.92 38 1000 0.75 3/8" 1/4" 22/28 B200 4.0 na
HGA4480ZHR 568 877 1057 1257 1480 1728 2324 1178 2.01 35 1000 0.75 3/8" 3/8" 25/31 B200 5.7 na
HGA4492ZHR 663 992 1185 1400 1639 1908 2559 1323 2.04 38 1000 0.75 1/2" 3/8" 26/32 B200 5.5 na
HGA4512ZHR 766 1170 1389 1621 1870 2138 2768 1561 1.83 39 1000 0.75 1/2" 3/8" 26/33 B200 7.1 na
CAJ/TAJN9480ZMH 533 877 1084 1315 1571 1852 2503 1212 1.66 33 900 1.50 1/2" 3/8" 33/35 M300 6.9 3.2
CAJ/TAJN9510ZMH 659 1058 1295 1557 1845 2159 2886 1455 1.63 34 900 1.50 5/8" 3/8" 33/35 M300 8.6 3.2
CAJ/TAJN9513ZMHR 774 1277 1569 1884 2219 2572 3351 1768 1.69 34 900 1.50 5/8" 3/8" 34/38 M300 11.5 4.1
CAJ/TAJN4517ZHR 1012 1629 2000 2415 2876 3386 4584 2229 1.85 40 1700 2.35 5/8" 3/8" 44/48 M350 13.5 4.4
CAJ/TAJN4519ZHR 1212 2023 2491 3002 3553 4148 5505 2788 1.65 40 1700 2.35 5/8" 3/8" 44/48 M350 16.0 5.6
FH/TFHT4522ZHR 1121 2068 2647 3290 3987 4720 6212 2942 1.82 43 1650 2.35 5/8" 3/8" 55/59 M350 17.1 6.5
FH/TFHT4524ZHR 1323 2390 3037 3751 4528 5359 7169 3377 1.73 49 3900 2.35 5/8" 3/8" 63/67 M420 20.7 8.8
FH/TFHT4531ZHR 1749 3075 3843 4684 5597 6586 8841 4285 1.81 50 3670 3.90 7/8" 1/2" 69/73 M420 23.5 9.3
AWT4538ZHR 2270 3871 4814 5852 6985 8219 11080 5352 2.81* 50 3300 3.90 7/8" 1/2" 67/81 M420 27 9.7b
TAGT4546ZHR 2423 4579 5924 7448 9147 11020 15330 6553 2.61* 55 7000 6.00 7/8" 1/2" 100/120 B420 na 15.6
TAGT4553ZHR 2751 5127 6580 8208 10007 11974 16475 7292 2.58* 54 7000 6.00 7/8" 5/8" 101/121 B420 na 16.3
TAGT4561ZHR 3326 5870 7419 9151 11061 13148 17911 8221 2.59* 55 7000 6.00 1"1/8 5/8" 101/121 B420 na 17.6
TAGT4568ZHR 3925 6682 8346 10204 12256 14509 19787 9286 2.58* 54 7000 6.00 1"1/8 5/8" 102/122 B420 na 20.1
TAGT4573ZHR 4447 7596 9448 11482 13703 16135 21976 10468 2.55* 54 6000 6.00 1"1/8 5/8" 107/127 B420 na 21.3
Statement of the seasonal COP / na: not applicable / a voltage code XC, b voltage code XG, c voltage code YZ, d voltage code MZ
R404A
* Special: Tropical units formerly called HTA.
29
Traditional condensing units
Statement of the seasonal COP/na: not applicable/a voltage code XC, b voltage code XG, c voltage code YZ, d voltage code MZ
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-25° -15° -10° -5° 0° 5° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
SHT4576ZHR 5271 8392 10169 12070 14084 16199 20811 10780 2.86* na 6000 6.00 1"1/8 5/8" 138/168 B420 na 13.9d
TAGT4581ZHR 5076 8324 10242 12350 14642 17118 22763 11386 2.56* 55 6000 6.00 1"1/8 5/8" 107/127 B420 na 23.1
TAGDT4590ZHR 4578 8623 11136 13971 17114 20550 28319 12367 2.88* 57 8270 9.50 1"1/8 5/8" 175/205 B420 na 28.9
SHT4591ZHR 6580 10265 12471 14911 17571 20434 na 13177 3.12* na 8270 9.50 1"1/8 5/8" 151/181 B420 na 15.0c
TAGDT4610ZHR 5409 9916 12668 15742 19122 22791 31048 14067 2.89* 56 8270 9.50 1"1/8 5/8" 179/209 B420 na 30.3
SHT4610ZHR 7621 12144 14686 17399 20301 23457 na 15504 2.72* na 14600 9.50 1"3/8 5/8" 180/210 B500 na 20.3c
TAGDT4612ZHR 6460 11583 14737 18282 22194 26434 35775 16334 2.69* 60 14600 9.50 1"1/8 5/8" 205/235 B500 na 33.3
SHT4612ZHR 8753 14010 16804 19670 22646 25873 na 17755 2.69* na 14600 9.50 1"3/8 5/8" 180/210 B500 na 22.7c
TAGDT4614ZHR 7961 13516 16982 20902 25248 29971 40468 18860 2.75* 59 14600 12.00 1"3/8 7/8" 209/235 B500 na 38.3
TAGDT4615ZHR 8748 15218 18919 22914 27208 31871 43225 20964 2.75* 59 13000 12.00 1"3/8 7/8" 217/247 B500 na 40.7
TAGDT4616ZHR 10065 17093 21021 25217 29706 34596 46777 23265 2.68* 60 13000 12.00 1"3/8 7/8" 216/246 B500 na 44.3
SHT4615ZHR 10456 16126 19556 23313 27299 31394 na 20766 2.78* na 14100 12.00 1"3/8 7/8" 227/257 B500 na 25.1d
SHT4620ZHR 14694 22161 26185 30419 34941 39949 na 27812 2.83* na 13000 12.00 1"3/8 7/8" 234/264 B500 na 35.1d
For information, the cooling capacity of fluids R449A and R448A: at the evaporation point To = -30°C, SH10K, apply the multiplier ratio 0.94 to the cooling capacities read with R404A.
30 TRADIT IONAL CONDENSING UNITS
MHBP
MODEL NUMBER
REFRIGERATION OUTPUT43° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-15° -10° -5° 0° 5° 10° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
AET4425YHR 194 259 330 408 491 579 674 346 1.48 28 410 0.75 3/8" 1/4" 19/20 M200 2.6 na
AET4430YHR 268 342 427 522 629 747 877 445 1.44 34 500 0.75 3/8" 1/4" 22/23 M250 3.5 na
AET4440YHR 359 446 546 658 783 923 / 585 1.54 38 500 0.75 3/8" 1/4" 24/26 M250 4.1 na
AET4450YHR 466 584 718 866 1032 1215 1417 767 1.62 38 800 0.75 3/8" 1/4" 27/28 M300 5.2 na
AET4456YHR 538 673 826 997 1187 1398 1631 877 1.67 38 1130 0.75 3/8" 1/4" 26/28 M300 8.6 na
AET4460YHR 551 693 853 1033 1233 1457 1709 907 1.81 37 1130 0.75 3/8" 1/4" 26/28 M300 5.3 na
CAJT4452YHR 416 552 705 877 1068 1279 1509 759 1.49 38 1130 1.50 1/2" 1/4" 33/37 M300 6.1 na
CAJ/TAJT4461YHR 539 691 867 1067 1292 1541 1813 923 1.59 37 1130 1.50 1/2" 1/4" 33/37 M300 6.5 2.6
CAJT4476YHR 579 773 993 1241 1519 1826 2161 1066 1.57 37 1130 1.50 1/2" 3/8" 36/40 M300 7.5 na
CAJ/TAJT4492YHR 783 1038 1326 1650 2013 2416 2862 1387 1.73 44 2250 2.35 1/2" 3/8" 45/49 M350 9.6 3.2
CAJ/TAJT4511YHR 1066 1373 1716 2097 2517 2978 3480 1810 1.96 45 2250 2.35 5/8" 3/8" 47/51 M350 9.3 3.7
Special condensing units*
Statement of the seasonal COP / na: not applicable
R513A
* Special: Tropical units formerly called HTA.
31
Traditional condensing units
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-15° -10° -5° 0° 5° 10° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
THB4410YH 111 142 178 220 272 330 397 153 1.33 26 340 / 1/4" 1/4" 14/15 M200 1.1 na
THB4413YH 129 165 206 255 311 375 447 179 1.24 27 340 / 1/4" 1/4" 14/15 M200 1.8 na
THB4415YHR 161 204 254 312 374 445 520 221 1.42 26 340 0.75 1/4" 1/4" 14/15 M200 1.5 na
THB4419YHR 188 235 290 354 425 505 595 255 1.42 26 340 0.75 3/8" 1/4" 14/15 M200 1.8 na
THB4422YHR 228 283 346 416 494 579 671 306 1.42 26 340 0.75 3/8" 1/4" 12/14 M200 2.5 na
AE4430YHR 320 403 499 610 734 871 1021 439 1.59 28 410 0.75 3/8" 1/4" 15/17 M200 3.3 na
AE4440YHR 415 509 616 737 871 1020 1182 556 1.59 28 410 0.75 3/8" 1/4" 19/21 M200 3.9 na
AE4450YHR 553 681 823 984 1164 1362 1578 741 1.62 38 500 0.75 3/8" 1/4" 19/21 M250 5.0 na
AE4456YHR 614 755 914 1094 1294 1519 1764 821 1.60 38 500 0.75 3/8" 1/4" 25/26 M250 6.2 na
AE4460YHR 633 781 948 1134 1342 1573 1826 850 1.70 39 500 0.75 3/8" 1/4" 25/27 M250 5.1 na
CAJN4452YHR 481 610 752 906 1070 1241 1416 666 1.50 27 550 1.50 1/2" 1/4" 29/30 M250 5.6 na
CAJ/TAJN4461YHR 585 723 876 1042 1220 1405 --- 793 1.50 27 550 1.50 1/2" 1/4" 29/30 M250 6.0 2.4
CAJN4476YHR 751 964 1207 1483 1795 2144 2531 1047 1.67 31 900 1.50 1/2" 3/8" 29/31 M300 7.1 na
CAJ/TAJN4492YHR 939 1192 1473 1782 2117 2471 2841 1297 1.79 32 900 2.35 1/2" 3/8" 30/32 M300 9.1 3
CAJ/TAJN4511YHR 1195 1478 1784 2110 2452 2803 --- 1616 1.89 33 900 2.35 5/8" 3/8" 31/33 M300 8.8 3.5
CAJN4513YHR 1397 1767 2195 2686 3245 3877 4583 1914 1.98 39 1700 2.35 5/8" 3/8" 39/43 M350 10.5 na
FH/TFHT4518YHR 1703 2267 2921 3666 4497 5404 6365 2459 1.87 40 1650 1.50 5/8" 3/8" 52/56 M350 11.8 4.8
FH/TFHT4525YHR 2396 3069 3842 4711 5665 6681 7726 3343 1.99 43 1650 1.50 5/8" 3/8" 53/56 M350 15.8 7.3
TAGT4528YHR 2853 3653 4546 5532 6615 7798 9092 3968 2.27 50 3900 2.35 7/8" 3/8" 72/76 M420 na 11.1
TAGT4534YHR 2931 3885 5007 6268 7652 9142 10721 4223 1.94 52 3670 2.35 7/8" 3/8" 75/89 M420 na 11.5
TAGT4537YHR 3343 4307 5380 6566 7875 9323 10933 4694 2.04 49 3670 2.35 7/8" 3/8" 74/89 M420 na 11.1
TAGT4543YHR 3785 4900 6135 7498 8999 10660 12516 5331 2.75* 50 3300 2.35 7/8" 3/8" 76/89 M420 na 11.1
TAGT4547YHR 3995 5158 6465 7925 9542 11321 13268 5621 2.35* 54 na 3.90 1"1/8 1/2" 87/90 M450 na 11.6
TAGDT4556YHR 4303 6286 8679 11457 14622 18181 22141 6803 3.09* 53 7000 3.90 1"1/8 1/2" 153/183 B420 na 22.3
TAGDT4568YHR 5910 7926 10312 13013 15992 19210 22618 8577 2.79* 53 6000 3.90 1"1/8 1/2" 158/188 B420 na 21.9
TAGDT4574YHR 7161 9368 11894 14760 17982 21575 25554 10156 3.07* 53 8270 6.00 1"1/8 5/8" 171/201 B420 na 23.3
TAGDT4586YHR 7742 10058 12640 15495 18629 22055 25800 10924 3.11* 53 7600 6.00 1"1/8 5/8" 175/205 B420 na 22.3
Statement of the seasonal COP / na: not applicable
32 TRADIT IONAL CONDENSING UNITS MHBP
Statement of the seasonal COP / na: not applicable
Traditional condensing units
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-15° -10 -5° 0° 5° 10° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
THB4410YH 103 134 170 213 264 322 388 143 1.32 26 340 na 1/4" 1/4" 14/15 M200 1.1 na
THB4413YH 120 156 197 246 302 366 437 167 1.23 27 340 na 1/4" 1/4" 14/15 M200 1.8 na
THB4415YHR 149 193 243 301 364 434 508 206 1.41 26 340 0.75 1/4" 1/4" 14/15 M200 1.5 na
THB4419YHR 174 222 278 342 413 493 582 238 1.41 26 340 0.75 3/8" 1/4" 14/15 M200 1.8 na
THB4422YHR 211 267 331 402 480 565 656 286 1.41 26 340 0.75 3/8" 1/4" 13/14 M200 2.5 na
AE4430YHR 297 381 478 589 713 849 998 410 1.58 28 410 0.75 3/8" 1/4" 16/17 M200 3.3 na
AE4440YHR 385 481 590 712 847 995 1155 519 1.58 28 410 0.75 3/8" 1/4" 20/21 M200 3.9 na
CAJN4452YHR 444 575 723 885 1061 1250 1449 620 1.48 27 550 1.50 1/2" 1/4" 29/31 M250 5.6 na
AE4450YHR 513 643 788 951 1131 1328 1542 692 1.61 38 500 0.75 3/8" 1/4" 20/21 M250 5.0 na
CAJ/TAJN4461YHR 541 685 846 1024 1218 1425 na 740 1.49 27 550 1.50 1/2" 1/4" 29/30 M250 6.0 2.4
AE4456YHR 569 713 875 1057 1258 1481 1724 767 1.59 38 500 0.75 3/8" 1/4" 25/27 M250 6.2 na
AE4460YHR 587 738 907 1096 1304 1534 1785 794 1.69 39 500 0.75 3/8" 1/4" 26/27 M250 5.1 na
CAJN4476YHR 700 915 1162 1442 1756 2104 2488 982 1.67 31 900 1.50 1/2" 3/8" 29/31 M300 7.1 na
CAJ/TAJN4492YHR 864 1120 1410 1733 2088 2474 2887 1203 1.77 32 900 2.35 1/2" 3/8" 30/32 M300 9.1 3.0
CAJ/TAJN4511YHR 1104 1396 1718 2067 2439 2831 na 1506 1.87 33 900 2.35 5/8" 3/8" 31/33 M300 8.8 3.5
CAJN4513YHR 1295 1669 2101 2595 3154 3781 4479 1787 1.97 39 1700 2.35 5/8" 3/8" 43/45 M350 10.5 na
FH/TFHT4518YHR 1564 2124 2783 3545 4408 5368 6414 2276 1.85 40 1650 1.50 5/8" 3/8" 52/56 M350 11.8 4.8
TAGT4528YHR 1979 2846 3866 5010 6253 7572 8948 3053 1.75 50 3900 2.35 7/8" 3/8" 72/76 M420 na 11.1
FH/TFHT4525YHR 2208 2888 3680 4583 5590 6689 7861 3106 1.97 43 1650 1.50 5/8" 3/8" 53/57 M350 15.8 7.3
TAGT4534YHR 2718 3670 4792 6056 7438 8916 10479 3943 1.93 52 3670 2.35 7/8" 3/8" 75/89 M420 na 11.5
TAGT4537YHR 3116 4131 5331 6684 8164 9749 11431 4444 1.94 49 3670 2.35 7/8" 3/8" 74/89 M420 na 11.1
TAGT4543YHR 3342 4407 5731 7271 8990 10861 12870 4734 1.95 50 3300 2.35 7/8" 3/8" 76/91 M420 na 11.1
TAGT4547YHR 3930 5153 6538 8084 9788 11652 13679 5526 2.56* 54 2500 3.90 1"1/8 1/2" 87/90 M450 na 11.6
TAGDT4556YHR 3990 5939 8307 11069 14212 17732 21641 6352 2.74* 53 7000 3.90 1"1/8 1/2" 153/183 B420 na 22.3
TAGDT4568YHR 5480 7488 9870 12573 15544 18735 22107 8009 2.77* 53 6000 3.90 1"1/8 1/2" 158/188 B420 na 21.9
TAGDT4574YHR 6362 8645 11395 14560 18086 21916 25995 9244 2.90* 53 8270 6.00 1"1/8 5/8" 171/201 B420 na 23.3
TAGDT4586YHR 6568 8766 11507 14703 18264 22108 26163 9388 2.78* 53 7600 6.00 1"1/8 5/8" 175/205 B420 na 22.3
MODEL NUMBER
REFRIGERATION OUTPUT43° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-15° -10° -5° 0° 5° 10° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
AET4425YHR 181 246 319 400 488 584 687 320 1.45 28 410 0.75 3/8" 1/4" 19/20 M200 2.6 na
AET4430YHR 250 325 412 512 625 752 894 412 1.41 34 500 0.75 3/8" 1/4" 22/23 M250 3.5 na
AET4440YHR 335 424 527 645 778 929 --- 541 1.51 38 500 0.75 3/8" 1/4" 24/26 M250 4.1 na
AET4450YHR 435 555 693 849 1025 1223 1445 709 1.59 38 800 0.75 3/8" 1/4" 27/28 M300 5.2 na
AET4456YHR 502 640 798 977 1179 1407 1663 811 1.64 38 1130 0.75 3/8" 1/4" 26/28 M300 8.6 na
AET4460YHR 514 659 824 1012 1225 1467 1743 839 1.77 37 1130 0.75 3/8" 1/4" 26/28 M300 5.3 na
CAJT4452YHR 387 524 681 859 1061 1287 1539 702 1.46 38 1130 1.50 1/2" 1/4" 33/37 M300 6.1 na
CAJ/TAJT4461YHR 502 657 838 1047 1285 1553 1853 853 1.56 37 1130 1.50 1/2" 1/4" 33/37 M300 6.5 2.6
CAJT4476YHR 549 747 971 1222 1500 1804 2135 999 1.56 37 1130 1.50 1/2" 3/8" 36/40 M300 7.5 na
CAJ/TAJT4492YHR 729 984 1277 1613 1994 2426 2910 1281 1.69 44 2250 2.35 1/2" 3/8" 45/49 M350 9.6 3.2
CAJ/TAJT4511YHR 995 1305 1657 2055 2501 2998 3549 1674 1.92 45 2250 2.35 5/8" 3/8" 47/51 M350 9.3 3.7
Special condensing units*
na: not applicable
R134a
* Special: Tropical units formerly called HTA.
33
MHBP
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco. P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-15° -10° -5° 0° 5° 10 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
AE4430NH 305 386 480 587 708 845 1000 430 1.56 28 410 na 3/8" 1/4" 15/16 M200 3.3 na
AE4440NH 382 479 589 713 853 1013 1196 535 1.52 28 410 na 3/8" 1/4" 15/17 M200 3.9 na
CAJ/TAJN4492NH 890 1145 1434 1758 2115 2496 2893 1276 1.75 32 900 na 1/2" 5/16" 30/32 M300 9.1 3.7
CAJ/TAJN4511NH 1116 1403 1723 2077 2466 2894 3368 1570 1.89 33 900 na 1/2" 5/16" 30/32 M300 8.8 4.4
CAJN4513NH 1232 1565 1946 2376 2860 3401 4006 1738 1.88 39 1700 na 1/2" 3/8" 39/43 M350 10.5 na
Traditional condensing units
Traditional condensing units
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-25° -15° -10° -5° 0° 5° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ
AE4425UH 162 269 332 399 483 572 783 359 1.54 30 340 na 3/8" 1/4" 17/19 M200 2.4
AE4430UH 198 331 414 504 617 734 984 447 1.70 29 410 na 3/8" 1/4" 18/19 M200 2.8
AE4440UH 277 440 537 636 762 891 1190 580 1.47 38 800 na 3/8" 1/4" 19/21 M250 3.9
AE4450UH 372 570 686 805 957 1115 1495 744 1.48 38 980 na 3/8" 1/4" 20/21 M250 5.0
AE4460UH 359 592 727 864 1036 1215 1655 789 1.38 40 980 na 3/8" 1/4" 20/21 M250 5.7
na: not applicable
na: not applicable
R1234yf
R290
MHBP
34 TRADIT IONAL CONDENSING UNITS
DIMENSIONSCONDENSING UNITS SPECIAL & TRADITIONAL
HGA THB AE2 AJ2 FH/AW TAG TAGD SH
M200or
B200
M250
M300
M320or
M350
M420or
M450
B420
B500
Height
Width
Depth
M = Single fan / B = Dual fan/ The 3 digits following the letter indicate the fan diameter in mm.
35
MODEL NUMBER Width Height Depth Base
CAJ/TAJT9480ZMHR 430 340 490 M300
CAJ/TAJT9510ZMHR 512 445 607 M320
CAJ/TAJT9513ZMHR 512 445 607 M350
CAJ/TAJT4517ZHR 512 445 607 M350
CAJ/TAJT4519ZHR 513 436 608 M350
MHBP SPE. R452A R404
MODEL NUMBER Width Height Depth Base
AE2410UB 300 227 374 M200
AE2415UB 300 227 374 M200
AE2420UB 322 257 404 M200
MODEL NUMBER Width Height Depth Base
AET2415ZBR 312 237 398 M200
AET2420ZBR 322 257 404 M200
CAJ/TAJN2428ZBR 345 304 511 M250
AET2425ZBR 346 303 501 M250
CAJN2432ZBR 345 304 511 M250
CAJN2440ZBR 432 340 488 M300
CAJ/TAJN2446ZBR 432 340 488 M300
CAJ/TAJN2464ZBR 432 340 488 M300
HGA2426ZBR 500 219 450 B200
HGA2432ZBR 500 219 450 B200
HGA2436ZBR 500 219 450 B200
HGA2446ZBR 700 219 450 B200
TFHT2480ZBR 512 436 607 M350
TFHT2511ZBR 512 436 607 M350
TAGT2513ZBR 591 540 685 M420
TAGT2516ZBR 710 540 685 M420
TAGT2519ZBR 760 608 642 M450
TAGT2522ZBR 760 608 642 M450
TAGT2525ZBR 755 608 685 M450
TAGDT2532ZBR 1060 589 703 B420
TAGDT2538ZBR 1060 589 703 B420
TAGDT2544ZBR 1060 589 703 B420
TAGDT2550ZBR 1060 589 703 B420
SHT2529ZBR 601 556 1060 B420
SHT2534ZBR 601 556 1060 B420
SHT2542ZBR 1417 665 720 B420
SHT2552ZBR 1417 665 720 B420
SHT2568ZBR 1417 860 720 B500
SHT2575ZBR 1417 860 720 B500
LBP R290
LBP R452A R404
MODEL NUMBER Width Height Depth Base
AET4425ZHR 322 257 404 M200
AET4430ZHR 322 257 404 M200
AET4440ZHR 346 303 501 M250
AET4450ZHR 346 303 501 M250
AET4460ZHR 433 338 496 M300
AET4470ZHR 433 338 496 M300
HGA4467ZHR 500 219 450 B200
HGA4480ZHR 700 219 450 B200
HGA4492ZHR 700 219 450 B200
HGA4512ZHR 700 219 450 B200
CAJ/TAJN9480ZMH 432 340 488 M300
CAJ/TAJN9510ZMH 432 340 488 M300
CAJ/TAJN9513ZMHR 432 340 488 M300
CAJ/TAJN4517ZHR 513 437 608 M350
CAJ/TAJN4519ZHR 513 437 608 M350
FH/TFHT4522ZHR 512 436 607 M350
FH/TFHT4524ZHR 591 540 625 M420
FH/TFHT4531ZHR 591 540 625 M420
AWT4538ZHR 592 540 647 M420
TAGT4546ZHR 1060 555 615 B420
TAGT4553ZHR 1060 555 615 B420
TAGT4561ZHR 1060 555 615 B420
TAGT4568ZHR 1060 555 615 B420
TAGT4573ZHR 1060 555 615 B420
SHT4576ZHR 1060 555 601 B420
TAGT4581ZHR 1060 555 615 B420
TAGDT4590ZHR 1417 868 720 B420
SHT4591ZHR 1417 660 720 B420
TAGDT4610ZHR 1417 868 720 B420
SHT4610ZHR 1417 860 720 B420
TAGDT4612ZHR 1417 868 720 B500
SHT4612ZHR 1417 860 720 B500
TAGDT4614ZHR 1417 868 720 B500
TAGDT4615ZHR 1417 868 720 B500
TAGDT4616ZHR 1417 868 720 B500
SHT4615ZHR 1417 860 720 B500
SHT4620ZHR 1417 860 720 B500
MHBP R452A R404
MODEL NUMBER Width Height Depth Base
AE4425UH 300 227 374 M200
AE4430UH 322 257 404 M200
AE4440UH 334 300 485 M250
AE4450UH 334 300 485 M250
AE4460UH 334 300 485 M250
MHBP R290MODEL NUMBER Width Height Depth Base
AE4430NH 322 257 378 M200
AE4440NH 322 257 378 M200
CAJ/TAJN4492NH 432 340 488 M300
CAJ/TAJN4511NH 432 340 488 M300
CAJN4513NH 512 437 607 M350
MHBP R1234yf
MODEL NUMBER Width Height Depth Base
THB4410YH 309 227 398 M200
THB4413YH 309 227 398 M200
THB4415YHR 309 227 398 M200
THB4419YHR 309 227 398 M200
THB4422YHR 309 227 398 M200
AE4430YHR 322 257 404 M200
AE4440YHR 322 257 404 M200
CAJN4452YHR 345 304 511 M250
AE4450YHR 346 303 501 M250
CAJ/TAJN4461YHR 345 304 511 M250
AE4456YHR 346 303 501 M250
AE4460YHR 346 303 501 M250
HGA4445YHR 500 218 450 B200
HGA4450YHR 500 218 450 B200
HGA4460YHR 500 218 450 B200
HGA4476YHR 700 218 450 B200
CAJN4476YHR 432 340 488 M300
CAJ/TAJN4492YHR 432 340 488 M300
CAJ/TAJN4511YHR 432 340 488 M300
CAJN4513YHR 513 437 608 M350
FH/TFHT4518YHR 512 436 607 M350
TAGT4528YHR 597 540 629 M420
FH/TFHT4525YHR 512 436 607 M350
TAGT4534YHR 597 540 629 M420
TAGT4537YHR 597 540 629 M420
TAGT4543YHR 597 540 629 M420
TAGT4547YHR 597 540 629 M450
TAGDT4556YHR 1060 589 703 B420
TAGDT4568YHR 1060 589 703 B420
TAGDT4574YHR 1417 868 720 B420
TAGDT4586YHR 1417 868 720 B420
MHBP R134a R513A
MODÈLE Width Height Depth Base
AET4425YHR 322 257 404 M200
AET4430YHR 336 298 486 M250
AET4440YHR 346 303 501 M250
AET4450YHR 433 338 496 M300
AET4456YHR 346 303 501 M300
AET4460YHR 346 303 501 M300
CAJT4452YHR 430 340 490 M300
CAJ/TAJT4461YHR 430 340 490 M300
CAJT4476YHR 430 340 490 M350
CAJ/TAJT4492YHR 512 445 607 M350
CAJ/TAJT4511YHR 512 445 607 M350
MHBP SPE. R134a R513AMODEL NUMBER Width Height Depth Base
CAJT2432ZBR 430 340 490 M300
CAJ/TAJT2446ZBR 430 340 490 M300
CAJ/TAJT2464ZBR 512 445 607 M350
LBP SPE. R452A R404
36 TRADIT IONAL CONDENSING UNITS
APPLICATION WINDOWSLBP R452A R404A
MODEL NUMBER
T/CAJN 2428 ZBR
T/CAJN 2440 ZBR
T/CAJN 2446 ZBR
CAJT 2432 ZBR
T/CAJT 2446 ZBR
T/CAJT 2464 ZBR
T/FHT 2480 ZBR
TAGT 2513 ZBR
TAGT 2516 ZBR
TAGT 2519 ZBR
TAGT 2522 ZBR
TAGT 2525 ZBR
SHT 2529 ZBR
SHT 2534 ZBR
MODEL NUMBER
T/CAJN 2432 ZBR
T/CAJT 2464 ZBR
SHT 2534 ZBR
MODEL NUMBER
SHT 2542 ZBR
Amb
T. (°
C)
Evap T. (°C)
46
43
-35 -30 -15 -10
Amb
T. (°
C)
Evap T. (°C)
46
43
-35 -30 -20 -15 -10
38
38
Amb
T. (°
C)
Evap T. (°C)
46
43
-35 -30 -20 -10
LBP R290MODEL NUMBER
AE 2410 UB
MODEL NUMBER
AE 2415 UB
AE 2420 UB
MODEL NUMBER
AE 4425 UH
AE 4430 UH
AE 4440 UH
MODEL NUMBER
AE 4450 UH
AE 4460 UH
Amb
T. (°
C)
Evap T. (°C)
46
43
-35 -30 -10
Amb
T. (°
C)
Evap T. (°C)
46
43
-35 -30 -15 -10
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +5 +15
38
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +5 +15
32
MHBP R290
For R449A/R448A refrigerants, refer to the recommendations for use on our website www.tecumseh.com
37
MHBP R452A R404A MHBP R134a R513A R1234yfMODEL NUMBER
T/CAJN 4517 ZHR
AET 4460 ZHR
AET 4470 ZHR
T/CAJT 9480 ZMHR
T/CAJT 9513 ZMHR
TAGT 4546 ZHR
TAGT 4553 ZHR
TAGT 4561 ZHR
TAGT 4573 ZHR
TAGDT 4612 ZHR
TAGDT 4614 ZHR
TAGDT 4616 ZHR
MODEL NUMBER
T/CAJN 9480 ZMHR
T/CAJN 4517 ZHR
AET 4425 ZHR
AET 4430 ZHR
AET 4440 ZHR
T/CAJT 9510 ZMHR
T/CAJT 4517 ZHR
T/CAJT 4519 ZHR
T/FHT 4522 ZHR
T/FHT 4524 ZHR
AWT 4538 ZHR
TAGT 4568 ZHR
TAGT 4581 ZHR
TAGDT 4590 ZHR
TAGDT 4610 ZHR
TAGDT 4615 ZHR
MODEL NUMBER
T/CAJN 9510 ZMHR
AET 4450 ZHR
T/FHT 4531 ZHR
MODEL NUMBER
T/CAJN 9513 ZMHR
SHT 4576 ZHR
SHT 4591 ZHR
SHT 4610 ZHR
SHT 4612 ZHR
SHT 4615 ZHR
SHT 4620 ZHR
MODEL NUMBER
THB 4419 YHR
THB 4410 YH
THB 4413 YH
T/CAJT 4492 YHR
MODEL NUMBER
AE 4456 YHR
THB 4422 YHR
T/CAJN 4476 YHR
AET 4450 YHR
AET 4456 YHR
AET 4460 YHR
T/CAJT 4461 YHR
T/CAJT 4476 YHR
T/CAJT 4511 YHR
TAGDT 4556 YHR
TAGDT 4568 YHR
TAGDT 4574 YHR
CAJN 4513 YHR
AE 4430 NH
T/CAJN 4492NH
CAJN 4513 NH
MODEL NUMBER
AE 4430 YHR
AE 4440 YHR
AE 4450 YHR
AE 4456 YHR
AE 4460 YHR
CAJN 4452 YHR
T/CAJN 4492 YHR
AET 4425 YHR
AET 4430 YHR
T/FHT 4525 YHR
TAGT 4528 YHR
TAGT 4534 YHR
TAGT 4547 YHR
TAGT 4586 YHR
AE 4440 NH
MODEL NUMBER
AE 4450 YHR
AE 4460 YHR
T/CAJN 4511 YHR
T/CAJN4511 NH
AE 4460 YHR
TAGT 4537 YHR
TAGT 4543 YHR
CAJN 4461 YHR
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 -15 +5 +15
38
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 -15 +5 +10 +15
38
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 -15 0 +5 +15
3832
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 -15 -5 0 +15
3832
27
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +10 +15
38
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +5 +10 +15
38
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 -15 0 +5 +15
3832
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 -15 -5 0 2 +15
3832
25
38 WINTSYS®
EQUIPMENTELECTRICAL COMPONENTS►Isolator switch►Contactor►Din Rail adapter with free length
CIRCUIT►Dryer filter►Liquid indicator
INSTALLATION/MAINTENANCE►Polypropylene shock-proof and anti-UV fairing► Corrosion resistance in accordance with standard NF EN ISO
9227 – 500-hour neutral salt spray test►Ground fixing
CONTROL► Thermostatic or pressure control of the compressor without addition-
al wiring►Pressure switch fault reporting terminals
FIXING
High energy efficiencyMeticulous assembly and aestheticsRecognised reliable product
Solution for demanding outdoor conditions
Direct access to the feet
39
WINTSYS®
39
40 WINTSYS®
LBP
LBP
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling, Mid/Mid
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -35°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-35° -30° -25° -20° -15° -10° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
WINAE2425Z 302 411 542 699 884 1100 340 0.94 26 1650 0.75 3/8" 1/4" 53/71 S 4.5 na
WINAJ2440Z 429 601 806 1048 1331 1662 484 0.95 27 1650 1.50 1/2" 1/4" 61/79 S 6.2 na
WINAJ2446Z 565 763 999 1280 1612 2003 643 1.03 27 1650 1.50 1/2" 3/8" 63/81 S 8.7 3.4
WINAJ2464Z 765 1026 1337 1699 2116 2589 867 1.02 28 1650 1.50 5/8" 3/8" 65/83 S 10.5 3.9
WINFH2480Z 1012 1407 1852 2351 2912 3543 1142 1.05 39 1650 2.35 5/8" 1/2" 74/95 M 16.7 7.0
WINFH2511Z 1353 1871 2488 3211 4049 5009 1531 1.08 42 2750 2.35 5/8" 1/2" 82/103 M 24.7 7.9
Wintsys®
na : not applicable
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling, Mid/Mid
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -35°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-35° -30° -25° -20° -15° -10° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
WINAE2425Z 306 412 540 690 867 1071 378 0.99 26 1650 0.75 3/8" 1/4" 53/71 S 4.5 na
WINAJ2440Z 436 595 787 1013 1277 1582 542 0.97 27 1650 1.50 1/2" 1/4" 61/79 S 6.2 na
WINAJ2446Z 573 768 999 1270 1586 1951 712 1.06 27 1650 1.50 1/2" 3/8" 63/81 S 8.7 3.4
WINAJ2464Z 774 1033 1337 1688 2087 2532 957 1.05 28 1650 1.50 5/8" 3/8" 65/83 S 10.5 3.9
WINFH2480Z 1056 1429 1851 2324 2853 3441 1311 1.11 39 1600 2.35 5/8" 1/2" 74/95 M 16.7 7.0
WINFH2511Z 1366 1882 2489 3190 3989 4889 1700 1.11 42 2750 2.35 5/8" 1/2" 82/103 M 24.7 7.9
Wintsys®
na : not applicable
R452A
R404A
For information, the cooling capacity of fluids R449A and R448A: at the evaporation point To = -30°C, SH10K, apply the multiplier ratio 0.94 to the cooling capacities read with R404A.
41
MHBP
MHBP
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling, Mid/Mid
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-25° -15° -10° -5° 0° 5° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
WINAE4450Z 368 638 805 1004 1237 1506 2167 820 1.78 27 1650 0.75 3/8" 1/4" 53/71 S 5.6 na
WINAE4460Z 470 771 957 1178 1436 1735 2470 981 1.84 28 1650 0.75 3/8" 1/4" 53/71 S 6.4 na
WINAE4470Z 474 833 1056 1324 1641 2019 3004 1081 1.66 29 1650 0.75 3/8" 1/4" 53/71 S 7.6 na
WINAJ9480Z 607 1027 1286 1590 1943 2348 3329 1316 1.90 30 1650 1.50 1/2" 3/8" 62/80 S 7.3 3.7
WINAJ9510Z 758 1263 1571 1934 2352 2830 3988 1614 1.93 30 1650 1.50 5/8" 3/8" 63/81 S 8.9 4.1
WINAJ9513Z 914 1568 1968 2432 2963 3566 5005 2021 2.08 30 1650 1.50 5/8" 3/8" 65/83 S 11.8 4.9
WINAJ4517Z 1008 1689 2094 2562 3097 3711 5216 2171 1.96 30 1650 2.35 5/8" 3/8" 65/83 S 13.2 4.7
WINAJ4519Z 1130 2093 2596 3171 3828 4587 6519 2708 1.72 32 1650 2.35 5/8" 3/8" 65/83 S 15.5 6.7
WINFH4524Z 1319 2439 3122 3911 4807 5821 8236 3213 1.83 39 2750 2.35 5/8" 1/2" 79/100 M 20.3 8.4
WINFH4531Z 1797 3150 3947 4868 5922 7129 10089 4092 1.90 41 2750 3.90 7/8" 1/2" 83/104 M 23.1 9.7
WINAW4538Z 2174 3851 4814 5877 7027 8267 11132 5008 2.98* 47 2750 3.90 7/8" 1/2" 79/100 M 27.0a 9.7b
Wintsys®
Statement of the seasonal COP / na: not applicable / a voltage code XC, b voltage code XG, c voltage code YZ, d voltage code MZ
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-25° -15° -10° -5° 0° 5° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
WINAE4450Z 370 627 790 980 1199 1450 2065 870 1.81 27 1650 0.75 3/8" 1/4" 53/70 S 5.6 na
WINAE4460Z 476 762 942 1152 1394 1673 2354 1039 1.87 28 1650 0.75 3/8" 1/4" 53/70 S 6.4 na
WINAE4470Z 547 888 1096 1334 1605 1912 2648 1209 1.87 29 1650 0.75 3/8" 1/4" 53/70 S 7.6 na
WINAJ9480Z 614 1014 1266 1556 1888 2265 3172 1396 1.92 30 1650 2.35 1/2" 3/8" 62/79 S 7.3 3.7
WINAJ9510Z 768 1248 1549 1894 2286 2730 3793 1710 1.95 30 1650 2.35 5/8" 3/8" 63/80 S 8.9 4.1
WINAJ9513Z 924 1548 1938 2382 2881 3440 4759 2143 2.10 30 1650 2.35 5/8" 3/8" 65/82 S 11.8 4.9
WINAJ4517Z 1016 1671 2066 2512 3012 3575 4941 2296 1.97 30 1650 2.35 5/8" 3/8" 65/82 S 13.2 4.7
WINAJ4519Z 1223 2068 2562 3108 3719 4408 6141 2860 1.73 32 1650 2.35 5/8" 3/8" 65/82 S 15.5 6.7
WINFH4524Z 1316 2397 3064 3817 4658 5593 7793 3405 1.84 39 2750 3.90 5/8" 1/2" 79/100 M 20.3 8.4
WINFH4531Z 1809 3112 3892 4767 5747 6847 9517 4333 1.91 41 2750 3.90 7/8" 1/2" 83/104 M 23.1 9.7
WINAW4538Z 2203 3774 4704 5724 6828 8007 10621 5239 2.97* 47 2970 3.90 7/8" 1/2" 79/100 M 27.0a 9.7b
Wintsys®
Statement of the seasonal COP / na: not applicable / a voltage code XC, b voltage code XG, c voltage code YZ, d voltage code MZ
R452A
R404A
For information, the cooling capacity of fluids R449A and R448A: at the evaporation point To = -30°C, SH10K, apply the multiplier ratio 0.94 to the cooling capacities read with R404A.
42 WINTSYS®
MHBP
MHBP
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-15° -10° -5° 0° 5° 10° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
WINAE4450Y 616 773 959 1178 1435 1734 2079 835 1.66 28 1650 0.75 3/8" 1/4" 53/71 S 5.1 na
WINAE4460Y 692 871 1081 1328 1614 1944 2318 941 1.96 28 1650 0.75 3/8" 1/4" 53/71 S 5.0 na
WINAJ4476Y 798 1032 1306 1626 1999 2429 2922 1117 1.72 28 1650 1.50 1/2" 3/8" 62/80 S 8.3 na
WINAJ4492Y 1035 1323 1656 2036 2466 2947 3480 1430 1.94 27 1650 1.50 1/2" 3/8" 62/80 S 9.4 3.8
WINAJ4511Y 1329 1675 2065 2503 2987 3516 4089 1815 2.10 29 1650 1.50 5/8" 3/8" 63/81 S 9.1 4.1
WINAJ4513Y 1425 1809 2248 2748 3313 3945 4650 1958 2.10 28 1650 1.50 5/8" 3/8" 63/81 S 10.4 na
WINFH4518Y 1685 2231 2863 3590 4416 5347 6387 2421 1.79 36 2750 2.35 5/8" 3/8" 75/96 M 11.9 4.9
WINFH4525Y 2377 3026 3776 4634 5606 6699 7919 3297 1.92 40 2750 2.35 5/8" 3/8" 77/98 M 15.9 7.4
Wintsys®
na : not applicable
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximumcurrent
according to voltage code
-15° -10° -5° 0° 5° 10° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ TZ
WINAE4450Y 571 730 918 1138 1395 1691 2032 780 1.65 28 1650 0.75 3/8" 1/4" 53/73 S 5.1 na
WINAE4460Y 642 823 1035 1283 1569 1896 2266 879 1.95 28 1650 0.75 3/8" 1/4" 53/73 S 5.0 na
WINAJ4476Y 740 975 1250 1571 1943 2369 2856 1043 1.71 28 1650 1.50 1/2" 3/8" 62/81 S 8.3 na
WINAJ4492Y 947 1235 1571 1960 2404 2908 3474 1319 1.91 27 1650 1.50 1/2" 3/8" 62/82 S 9.4 3.8
WINAJ4511Y 1220 1568 1967 2418 2924 3486 4105 1679 2.07 29 1650 1.50 5/8" 3/8" 63/83 S 9.1 4.1
WINAJ4513Y 1307 1691 2136 2648 3231 3893 4641 1809 2.07 28 1650 1.50 5/8" 3/8" 63/83 S 10.4 na
WINFH4518Y 1548 2091 2730 3473 4330 5308 6421 2242 1.76 36 2750 2.35 5/8" 3/8" 75/101 M 11.9 4.9
WINFh4525Y 2190 2848 3616 4504 5523 6686 8012 3062 1.89 40 2750 2.35 5/8" 3/8" 77/104 M 15.9 7.4
Wintsys®
na : not applicable
R513A
R134a
43
DIMENSIONSWintsys®
A B C
S 942 654 710
M 1174 654 710
SIZE S
SIZE M
44 WINTSYS®
APPLICATION WINDOWSLBP R452A R404A
MODEL NUMBER
WIN AE 2425 Z
WIN AJ 2440 Z
WIN AJ 2446 Z
WIN AJ 2464 Z
WIN FH 2480 Z
WIN FH 2511 Z
MHBP R452A R404AMODEL NUMBER
WIN AE 4450 Z
WIN AE 4460 Z
WIN AE 4470 Z
WIN AJ 9480 Z
WIN AJ 9510 Z
WIN AJ 9513 Z
MODEL NUMBER
WIN AJ 4517 Z
WIN FH 4524 Z
MODEL NUMBER
WIN AJ 4519 Z
WIN FH 4531 Z
WIN FH 4538 Z
MHBP R134a R513AMODEL NUMBER
WIN AE 4450 Z
WIN AE 4460 Z
WIN AE 4476 Z
WIN AJ 4492 Z
MODEL NUMBER
WIN AJ 4511 Z
WIN AJ 4513 Z
WIN FH 4518 Z
MODEL NUMBER
WIN FH 4525 Z
Amb
T. (°
C)
Evap T. (°C)
43
-35 -30 -10
38
46
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +15
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +10 +15
38
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +5 +15
38
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +15
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +10 +15
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +5 +15
38
For R449A/R448A refrigerants, refer to the recommendations for use on our website www.tecumseh.com
4545
46 S ILENSYS®
EQUIPMENTELECTRICAL COMPONENTS = ENHANCED SAFETY► Magneto-thermal circuit breaker on the compressor► Fan circuit breaker► Pressure switch fault refferal terminals► Din Rail adapter accessible and with free length
CIRCUIT► Isolation of the suction line► Service valves on the reservoir bottle
FIXING► Ensures the minimum distance between the condenser and the wall ► Direct access to the mounting feet► Fixing on the ground and the wall with the original feet
ACOUSTICS►Compressor isolated in a separate compartment ►Fan speed variation►Muffler on the discharge►Reduction of radiated noise by means of an insulated door► Absorption of vibration through special bends on the copper tubes
Acoustic benchmarkRobustness and reliabilityEnhanced safety
Acoustic and aesthetic solution for urban areas
47
SILENSYS®
47
48 S ILENSYS®
LBP
R452A
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling, Mid/Mid
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -35°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximum current according to voltage
code
-35° -30° -25° -20° -15° -10° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ KZ TZ
SILRG2426Z 315 412 530 671 836 1028 356 1.03 26 1650 0.75 3/8" 1/4" 61/78 S 3.7 na na
SILRG2432Z 387 504 642 805 994 1211 439 1.08 27 1650 0.75 3/8" 1/4" 61/78 S 4.5 na na
SILAJ2432Z 350 506 697 927 1198 1511 392 0.88 26 1650 1.50 1/2" 1/4" 71/88 S 6.2 na na
SILAJ2440Z 429 601 806 1048 1331 1662 484 0.95 26 1650 1.50 1/2" 1/4" 70/87 S 6.0 na na
SILRG2446Z 523 682 874 1101 1367 1674 594 1.12 27 1650 1.50 3/8" 1/4" 63/80 S 5.7 na na
SILAJ2446Z 564 761 996 1276 1607 1996 643 1.03 26 1650 1.50 1/2" 3/8" 72/89 S 8.5 na 3.2
SILAJ2464Z 765 1026 1337 1699 2116 2589 867 1.02 27 1650 1.50 1/2" 3/8" 74/91 S 10.3 na 4.1
SILFH2480Z 1012 1403 1847 2345 2904 3532 1142 1.05 39 1650 2.35 5/8" 1/2" 74/95 M 17.3 11.7 6.6
SILFH2511Z 1350 1866 2481 3202 4037 4994 1415 0.98 44 2700 2.35 5/8" 1/2" 71/92 M 26.0 14.4 8.3
SILAG2513Z 1351 1962 2665 3464 4365 5387 1518 0.97 40 2970 3.90 7/8" 1/2" 103/119 M na 20.4 9.3
SILAG2516Z 1756 2530 3424 4436 5566 6821 1970 1.16 38 2970 3.90 7/8" 1/2" 128/144 M na 25.3 10.3
SILAG2519Z 2055 2891 3855 4945 6158 7505 2321 1.61* na 2970 3.90 7/8" 1/2" 108/129 M na na 11.2
SILAG2522Z 2349 3250 4295 5486 6835 8366 2669 1.62* 40 2700 3.90 7/8" 1/2" 112/128 M na 30.2 14.2
SILAG2525Z 2614 3591 4695 5930 7306 8850 2971 1.60* 44 2700 3.90 7/8" 1/2" 112/128 M na 26.7 14.1
SILAGD2532Z 3488 5112 7061 9332 11903 14726 3900 1.65* 43 6600 9.50 1"1/8 5/8" 236/257 XL na na 22.0
SILAGD2538Z 3972 5678 7728 10115 12803 15727 4491 1.66* na 6600 9.50 1"1/8 5/8" 236/257 XL na na 22.0
SILSH2534Z 4315 5849 7647 9729 12110 14812 4425 1.71* 44 5000 12.00 1"3/8 5/8" 244/265 XL na na 16.2c
SILAGD2544Z 5002 6883 9147 11793 14795 18097 5725 1.72* 43 6600 9.50 1"1/8 5/8" 252/273 XL na na 28.0
Silensys®
Statement of the seasonal COP / na: not applicable / a voltage code XC, b voltage code XG, c voltage code YZ, d voltage code MZ
49
LBP
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -35°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximum current according to voltage
code
-35° -30° -25° -20° -15° -10° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ KZ TZ
SILRG2426Z 268 359 470 601 754 930 331 0.89 26 1650 0.75 3/8" 1/4" 61/78 S 3.7 na na
SILRG2432Z 351 457 586 739 916 1116 435 0.98 27 1650 0.75 3/8" 1/4" 61/88 S 4.5 na na
SILAJ2432Z 380 531 714 931 1184 1476 469 1.03 26 1650 1.50 1/2" 1/4" 71/87 S 6.2 na na
SILAJ2440Z 449 611 807 1037 1306 1618 555 1.01 26 1650 1.50 1/2" 1/4" 70/80 S 6.0 na na
SILRG2446Z 467 612 786 992 1231 1506 579 1.02 27 1650 1.50 3/8" 1/4" 63/92 S 5.7 na na
SILAJ2446Z 573 768 999 1270 1586 1951 712 1.07 26 1650 1.50 1/2" 3/8" 72/91 S 8.5 na 3.2
SILAJ2464Z 774 1033 1337 1688 2087 2532 957 1.09 27 1650 1.50 1/2" 3/8" 74/91 S 10.3 na 4.1
SILFH2480Z 1056 1429 1851 2324 2853 3441 1311 1.11 39 1650 2.35 5/8" 1/2" 74/91 M 17.3 11.7 6.6
SILFH2511Z 1357 1867 2472 3177 3988 4912 1688 1.13 44 2700 2.35 5/8" 1/2" 71/124 M 26.0 14.4 8.3
SILAG2513Z 1380 1974 2657 3427 4285 5238 1726 1.01 40 2970 3.90 7/8" 1/2" 103/144 M na 20.4 9.3
SILAG2516Z 1786 2535 3409 4400 5498 6690 2225 1.67* 38 2970 3.90 7/8" 1/2" 128/124 M na 25.3 10.3
SILAG2519Z 2030 2816 3731 4768 5913 7153 2540 1.67* na 2970 3.90 7/8" 1/2" 108/133 M na na 11.2
SILAG2522Z 2396 3275 4295 5454 6749 8180 2991 1.70* 40 2700 3.90 7/8" 1/2" 112/128 M na 30.2 14.2
SILAG2525Z 2619 3554 4614 5794 7092 8510 3276 1.66* 44 2700 3.90 7/8" 1/2" 112/252 M na 26.7 14.1
SILAGD2532Z 3508 5096 7003 9220 11715 14422 4378 1.73* 43 6600 9.50 1"1/8 5/8" 236/257 XL na na 22.0
SILSH2534Z-YZ 4406 5880 7583 9525 11716 14173 4950 1.86* 44 5000 12.00 1"3/8 5/8" 244/265 XL na na 16.2b
SILAGD2538Z 3999 5676 7686 10014 12613 15397 5009 1.74* na 6600 9.50 1"1/8 5/8" 236/272 XL na na 22.0
SILAGD2544Z 4551 6328 8453 10905 13620 16485 5710 1.76* 43 6600 9.50 1"1/8 5/8" 252/286 XL na na 28.0
Silensys®
Statement of the seasonal COP / na: not applicable / a voltage code XC, b voltage code XG, c voltage code YZ, d voltage code MZ
R404A
For information, the cooling capacity of fluids R449A and R448A: at the evaporation point To = -30°C, SH10K, apply the multiplier ratio 0.94 to the cooling capacities read with R404A.
50 S ILENSYS®
MHBP
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling, Mid/Mid
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximum current according to voltage
code
-25° -15° -10° -5° 0° 5° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ KZ TZ
SILAE4450Z 368 638 805 1004 1237 1506 2167 820 1.78 27 1620 0.75 3/8" 1/4" 73/87 S 5.4 na na
SILAE4460Z 470 771 957 1178 1436 1735 2470 981 1.84 27 1620 0.75 3/8" 1/4" 72/86 S 6.2 na na
SILRG4467Z 498 800 986 1206 1462 1757 2478 1013 2.16 26 1650 0.75 3/8" 1/4" 62/79 S 4.8 na na
SILRG4480Z 595 951 1170 1429 1730 2079 2941 1203 2.20 26 1650 1.50 3/8" 3/8" 62/79 S 5.6 na na
SILAJ9480Z 607 1027 1286 1590 1943 2348 3329 1316 1.90 28 1650 1.50 1/2" 3/8" 70/87 S 7.0 na 3.7
SILRG4492Z 669 1066 1307 1591 1918 2294 3204 1350 2.21 26 1650 1.50 1/2" 3/8" 63/80 S 6.2 na na
SILAJ9510Z 758 1252 1554 1908 2318 2789 3942 1600 1.86 26 1650 1.50 5/8" 3/8" 72/89 S 8.7 na 4.1
SILRG4512Z 836 1329 1628 1977 2378 2836 3934 1681 2.20 26 1650 1.50 1/2" 3/8" 65/82 S 7.0 na na
SILAJ9513Z 914 1568 1968 2432 2963 3566 5005 2021 2.08 26 1650 1.50 5/8" 3/8" 74/91 S 11.6 na 4.7
SILAJ4517Z 1008 1689 2094 2562 3097 3711 5216 2171 1.96 27 1650 2.35 5/8" 3/8" 73/92 S 13.0 6.3 4.7
SILAJ4519Z 1226 2093 2596 3171 3828 4587 6519 2708 1.72 28 1650 2.35 5/8" 3/8" 74/91 S 15.5 11.2 6.5
SILFH4524Z 1319 2439 3122 3911 4807 5821 8236 3213 1.82 35 2700 2.35 5/8" 1/2" 69/90 M 20.8 11.1 8.9
SILFH4531Z 1797 3150 3947 4868 5922 7129 10089 4092 1.90 45 2700 3.90 7/8" 1/2" 72/93 M 24.0 14.6 9.4
SILAW4538Z 2174 3851 4814 5877 7027 8267 11132 5008 2.98* 38 2700 3.90 7/8" 1/2" 80/111 M 27.0a na 9.7b
SILAG4546Z 2306 4485 5791 7249 8873 10703 15357 5957 2.66* 46 5940 6.00 7/8" 1/2" 128/143 L na 23.7 14.9
SILAG4553Z 2712 5259 6774 8458 10326 12418 17663 6956 2.72* 48 5940 6.00 7/8" 5/8" 133/149 L na 27.8 15.6
SILAG4561Z 3123 5763 7276 8933 10765 12843 18374 7550 2.60* 47 5940 6.00 1"1/8 5/8" 134/149 L na 30.0 16.9
SILAG4568Z 3900 6941 8738 10745 12998 15766 22218 9047 2.75* 43 5940 6.00 1"1/8 5/8" 138/153 L na 36.0 19.4
SILAG4573Z 4297 7392 9228 11267 13534 16083 22551 9595 2.59* 42 5940 6.00 1"1/8 5/8" 139/154 L na 33.0 20.6
SILAG4581Z 4728 8333 10448 12783 15345 18157 24773 10813 2.59* 42 5400 6.00 1"1/8 5/8" 145/154 L na 39.0 22.0
SILAGD4590Z 4621 8988 11750 14884 18351 22082 30018 12034 3.06* 47 6600 9.50 1"1/8 5/8" 246/267 XL na na 25.0
SILAGD4610Z 5252 10038 13002 16321 19936 23756 31589 13381 3.00* 47 6600 9.50 1"1/8 7/8" 249/270 XL na na 29.0
SILSH4591Z 6469 10317 13317 15411 18461 21862 na 13192 3.29* na 6600 12 1"3/8 5/8" 244/264 XL na na 15.1c
SILAGD4612Z 6111 12232 14352 17852 21514 25375 33102 14858 2.92* 48 6600 12 1"3/8 7/8" 253/274 XL na na 32.0
SILAGD4614Z 7381 12937 16356 20135 24158 28253 36338 17045 2.94* 45 6600 12 1"3/8 7/8" 256/277 XL na na 37.0
SILAGD4615Z 8081 13829 17286 21048 24986 28917 36431 18100 2.76* 45 6600 12 1"3/8 7/8" 257/278 XL na na 39.0
Silensys®
Statement of the seasonal COP / na: not applicable/a voltage code XC, b voltage code XG, c voltage code YZ, d voltage code MZ
R452A
51
MHBP
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximum current according to voltage
code
-25° -15° -10° -5° 0° 5° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ KZ TZ
SILAE4450Z 370 627 790 980 1199 1450 2065 870 1.81 27 1620 0.75 3/8" 1/4" 73/90 S 5.4 na na
SILRG4467Z 456 729 906 1114 1353 1628 2299 999 2.07 26 1650 0.75 3/8" 1/4" 62/79 S 4.8 na na
SILAE4460Z 476 762 942 1152 1394 1673 2354 1039 1.87 27 1620 0.75 3/8" 1/4" 72/89 S 6.2 na na
SILRG4480Z 559 888 1101 1349 1635 1963 2763 1214 2.09 26 1650 1.50 3/8" 3/8" 62/79 S 5.6 na na
SILRG4492Z 625 988 1220 1488 1797 2149 3010 1349 2.15 26 1650 1.50 1/2" 3/8" 63/80 S 6.2 na na
SILAJ9480Z 614 1014 1266 1556 1888 2265 3172 1396 1.93 28 1650 2.35 1/2" 3/8" 70/87 S 7.0 na 3.7
SILAJ9510Z 768 1248 1549 1894 2286 2730 3793 1710 1.95 26 1650 2.35 5/8" 3/8" 72/89 S 8.7 na 4.1
SILRG4512Z 811 1279 1570 1901 2277 2703 3730 1736 2.19 26 1650 1.50 1/2" 3/8" 65/82 S 7.0 na na
SILAJ9513Z 886 1518 1894 2313 2780 3298 4515 2094 2.05 26 1650 2.35 5/8" 3/8" 74/91 S 11.6 na 4.7
SILAJ4517Z 1016 1671 2066 2512 3012 3575 4941 2296 1.97 27 1650 2.35 5/8" 3/8" 73/90 S 13.0 6.3 4.7
SILAJ4519Z 1223 2068 2562 3108 3719 4408 6141 2860 1.73 28 1650 2.35 5/8" 3/8" 74/91 S 15.5 11.2 6.5
SILFH4524Z 1316 2397 3064 3817 4658 5593 7793 3405 1.85 35 2970 2.35 5/8" 1/2" 69/90 M 20.8 11.1 8.9
SILFH4531Z 1809 3112 3892 4767 5747 6847 9517 4333 1.93 45 2970 3.90 7/8" 1/2" 72/93 M 24.0 14.6 9.4
SILAW4538Z 2203 3774 4704 5724 6828 8007 10621 5239 2.97* 38 2970 3.90 7/8" 1/2" 80/101 M 27.0a na 9.7b
SILAG4546Z 2348 4317 5543 6931 8485 10212 14292 6158 2.65* 46 5940 6.00 7/8" 5/8" 128/144 L na 23.7 14.9
SILAG4553Z 2838 5097 6499 8087 9866 11845 16509 7206 2.70* 48 5940 6.00 7/8" 5/8" 133/149 L na 27.8 15.6
SILAG4561Z 3227 5562 6976 8562 10327 12288 16972 7773 2.58* 47 5940 6.00 1"1/8 5/8" 134/150 L na 30.0 16.9
SILAG4568Z 3993 6733 8412 10313 12450 14851 20688 9352 2.73* 43 5940 6.00 1"1/8 5/8" 138/154 L na 36.0 19.4
SILAG4573Z 4347 7177 8900 10831 12980 15363 21042 9912 2.57* 42 5940 6.00 1"1/8 5/8" 139/155 L na 33.0 20.6
SILAG4581Z 4738 8103 10097 12304 14722 17353 23332 11208 2.58* 42 5400 6.00 1"1/8 5/8" 145/161 L na 39.0 22.0
SILAGD4590Z 4545 8769 11430 14447 17779 21364 28970 12674 3.10* 47 6600 9.50 1"1/8 5/8" 246/267 XL na na 25.0
SILSH4591Z 6462 10228 12510 15065 17899 21016 na 13215 3.15* na 6600 9.50 1"3/8 5/8" 244/264 XL na na 15.1c
SILAGD4610Z 5181 9819 12683 15885 19372 23056 30582 14087 3.04* 47 6600 9.50 1"1/8 7/8" 249/270 XL na na 29.0
SILAGD4612Z 6064 11025 14037 17368 20949 24673 32059 15622 2.95* 48 6600 12.00 1"3/8 7/8" 253/274 XL na na 32.0
SILAGD4614Z 7385 12735 16024 19658 23529 27468 34966 17893 2.96* 45 6600 12.00 1"3/8 7/8" 256/277 XL na na 37.0
SILAGD4615Z 8093 13654 16995 20631 24439 28238 35112 19007 2.78* 45 6600 12.00 1"3/8 7/8" 257/278 XL na na 39.0
Silensys®
Statement of the seasonal COP / na : not applicable
R404A
For information, the cooling capacity of fluids R449A and R448A: at the evaporation point To = -30°C, SH10K, apply the multiplier ratio 0.94 to the cooling capacities read with R404A.
52 S ILENSYS®
MHBP
MHBP
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling, Mid/Mid
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco. P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximum current according to voltage
code
-15° -10° -5° 0° 5° 10 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ KZ TZ
SILRG4445Y 414 530 674 846 1048 1283 1550 566 1.79 26 1650 0.75 3/8" 1/4" 61/78 S 3.9 na na
SILRG4450Y 504 644 815 1020 1262 1544 1868 688 1.76 26 1650 0.75 3/8" 1/4" 61/78 S 4.2 na na
SILRG4460Y 560 713 902 1133 1409 1736 2119 762 1.84 26 1650 0.75 1/2" 1/4" 62/79 S 4.6 na na
SILAE4450Y 571 730 918 1138 1395 1691 2032 780 1.90 27 1620 0.75 3/8" 1/4" 73/87 S 4.9 na na
SILAJ4461Y 633 827 1060 1338 1666 2049 2493 883 1.71 26 1650 1.50 1/2" 1/4" 68/85 S 6.1 na 2.5
SILRG4476Y 734 932 1169 1447 1768 2136 2553 996 1.96 26 1650 1.50 1/2" 3/8" 62/79 S 5.8 na na
SILAJ4476Y 740 975 1250 1571 1943 2369 2856 1043 1.71 26 1650 1.50 1/2" 3/8" 70/87 S 7.2 na na
SILAJ4492Y 947 1235 1571 1960 2404 2908 3474 1319 1.91 26 1650 1.50 1/2" 3/8" 70/87 S 9.2 na 3.1
SILAJ4511Y 1220 1568 1967 2418 2924 3486 4105 1679 2.08 27 1650 1.50 5/8" 3/8" 72/89 S 8.9 na 3.9
SILFH4518Y 1548 2091 2730 3473 4330 5308 6421 2242 1.76 33 2700 2.35 5/8" 3/8" 85/106 M 12.4 8.1 5.4
SILFH4525Y 2190 2848 3616 4504 5523 6686 8012 3062 1.89 40 2700 2.35 5/8" 3/8" 87/108 M 16.4 13.1 7.9
SILAG4528Y 1956 2851 3904 5093 6397 7805 9313 3048 2.01 39 2700 3.90 7/8" 1/2" 102/123 M na 24.8 10.8
SILAG4534Y 2693 3705 4910 6282 7792 9413 11117 3964 2.20 37 2700 3.90 7/8" 1/2" 104/126 M na 24.8 10.6
SILAG4537Y 3203 4332 5685 7235 8955 10823 12819 4632 2.29 37 2700 3.90 7/8" 1/2" 104/125 M na 24.8 10.2
SILAG4543Y 3353 4489 5910 7578 9455 11509 13716 4801 2.24 38 2700 3.90 7/8" 1/2" 107/128 M na 24.8 11.5
SILAG4547Y 3968 5249 6727 8412 10313 12440 14808 5623 2.61 37 2700 3.90 7/8" 1/2" 107/128 M na na 11.3
SILAGD4556Y 3935 5809 8048 10602 13424 16474 19725 6197 2.56 43 6600 9.50 1"1/8 5/8" 234/255 XL na na 21.0
SILAGD4568Y 5404 7530 10108 13078 16362 19858 23438 8048 2.88 42 6600 9.50 1"1/8 5/8" 236/256 XL na na 23.0
SILAGD4574Y 6242 8474 11180 14302 17775 21528 25479 9063 2.81 42 6600 9.50 1"1/8 5/8" 246/266 XL na na 21.0
SILAGD4586Y 6645 8995 11983 15536 19561 23948 28574 9621 2.96 42 6600 9.50 1"1/8 5/8" 246/267 XL na na 24.0
Silensys®
na: not applicable
MODEL NUMBER
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C)
REFRIG. OUTPUT EN13215
Evap. T -10°CAco. P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Maximum current according to voltage
code
-15° -10° -5° 0° 5° 10 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line FZ KZ TZ
SILAE4450Y 616 773 959 1178 1435 1734 2079 835 1.66 28 1650 0.75 3/8" 1/4" 73/87 S 4.9 na na
SILAJ4461Y 691 885 1117 1391 1712 2083 2507 957 1.74 26 1650 1.50 1/2" 1/4" 68/85 S 6.1 na 2.5
SILAJ4476Y 798 1032 1306 1626 1999 2429 2922 1117 1.98 26 1650 1.50 1/2" 3/8" 70/79 S 7.2 na na
SILAJ4492Y 1035 1323 1656 2036 2466 2947 3480 1430 1.94 26 1650 1.50 1/2" 3/8" 70/87 S 9.2 na 3.1
SILAJ4511Y 1329 1675 2065 2503 2987 3516 4089 1815 2.10 27 1650 1.50 5/8" 3/8" 72/89 S 8.9 na 3.9
SILFH4518Y 1685 2231 2863 3590 4416 5347 6387 2421 1.79 33 2970 2.35 5/8" 3/8" 85/106 M 12.4 8.1 5.4
SILFH4525Y 2377 3026 3776 4634 5606 6699 7919 3297 1.92 40 2970 2.35 5/8" 3/8" 87/108 M 16.4 13.1 7.9
SILAG4528Y 2958 3788 4716 5749 6897 8179 9620 4106 2.54 39 2970 3.90 7/8" 1/2" 102/123 M na 24.8 10.8
SILAG4534Y 3173 4135 5226 6453 7820 9331 10992 4486 2.33 37 2970 3.90 7/8" 1/2" 104/126 M na 24.8 10.6
SILAG4537Y 3608 4698 5936 7330 8893 10636 12584 5092 2.36 37 2970 3.90 7/8" 1/2" 104/125 M na 24.8 10.2
SILAG4543Y 3968 5168 6515 8018 9687 11538 13596 5603 3.02* 38 2970 3.90 7/8" 1/2" 107/128 M na 24.8 11.5
SILAG4547Y 4325 5606 7062 8700 10523 12531 14723 6078 2.63* 37 2970 3.90 7/8" 1/2" 107/128 M na 24.8 11.3
SILAGD4556Y 5950 7738 9763 12036 14576 17406 20570 8364 3.32* 43 6600 9.50 1"1/8 5/8" 234/255 XL na na 22.3
SILAGD4568Y 6371 8425 10801 13507 16528 19824 23329 9127 3.14* 42 6600 9.50 1"1/8 5/8" 236/257 XL na na 21.9
SILAGD4574Y 6992 9163 11652 14478 17651 21176 25051 9935 2.96* 42 6600 9.50 1"1/8 5/8" 246/267 XL na na 23.0
SILAGD4586Y 7852 10358 12232 16489 20124 24119 28436 11232 3.31* 42 6600 9.50 1"1/8 5/8" 246/267 XL na na 24.0
Silensys®
Statement of the seasonal COP / na: not applicable
R134a
R513A
53
A B C
S 942 654 837
M 1174 654 837
L 1209 654 1465
XL 1666 654 1457
SIZE S SIZE M
SIZE L SIZE XL
A
C
A
C
DIMENSIONSSilensys®
B
A
C
B
B
A
C
B
54 S ILENSYS®
APPLICATION WINDOWSLBP R452A R404A
MODEL NUMBER
SIL RG 2426 Z
SIL RG 2432 Z
SIL RG 2446 Z
SIL AJ 2432 Z
SIL AJ 2440 Z
SIL AJ 2446 Z
SIL AJ 2464 Z
SIL FH 2480 Z
SIL FH 2511 Z
SIL AG 2513 Z
SIL AG 2516 Z
SIL AG 2519 Z
SIL AG 2522 Z
SIL AG 2525 Z
SIL AGD 2532 Z
SIL AGD 2538 Z
SIL AGD 2544 Z
SIL SH 2534 Z
MHBP R452A R404A
MODEL NUMBER
SIL AE 4450 Z
SIL AE 4460 Z
SIL RG 4467 Z
SIL RG 4480 Z
SIL RG 4492 Z
SIL RG 4512 Z
SIL AJ 9480 Z
SIL AJ 9510 Z
SIL AJ 9513 Z
MODEL NUMBER
SIL AJ 4517 Z
SIL FH 4524 Z
SIL AG 4553 Z
SIL AG 4581 Z
SIL AGD 4590 Z
MODEL NUMBER
SIL AJ 4519 Z
SIL FH 4531 Z
SIL AW 4538 Z
SIL AG 4546 Z
SIL AG 4561 Z
SIL AG 4568 Z
SIL AG 4573 Z
SIL AGD 4610 Z
SIL AGD 4612 Z
MODEL NUMBER
SIL AGD 4614 Z
SIL AGD 4615 Z
SIL SH 4591 Z
Amb
T. (°
C)
Evap T. (°C)
43
-25 -20 +10
46
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +15
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +10 +15
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +5 +15
38
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 0 +15
32
For R449A/R448A refrigerants, refer to the recommendations for use on our website www.tecumseh.com
55
MHBP R513A R134a
MODEL NUMBER
SIL RG 4445 Y
SIL RG 4450 Y
SIL RG 4460 Y
SIL RG 4476 Y
SIL AE 4450 Y
SIL AJ 4461 Y
SIL AJ 4476 Y
SIL AJ 4492 Y
SIL AGD 4556 Y
SIL AGD 4568 Y
SIL AGD 4574 Y
MODEL NUMBER
SIL AJ 4511 Y
SIL FH 4518 Y
SIL AG 4528 Y
SIL AG 4534 Y
SIL AG 4537 Y
SIL AG 4543 Y
SIL AG 4547 Y
SIL AGD 4586 Y
MODEL NUMBER
SIL FH 4525 Y
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +15
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +10 +15
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +5 +15
38
56 S ILENSYS® INVERTER
Acoustic level of the SILENSYS®
REGULATION OF THE REFRIGERATING SYSTEM:► Dual control, inverter/pressure-actuated mode, ensuring continuity of
the cold without additional wiring► Variation of capacity thanks to a frequency variator► Supply of 2 or 3 evaporators► Energy efficiency: the capacity variation permits balanced energy
and optimum efficiency: reduction of power consumption by up to 25%
►Precise regulation ensuring better temperature and humidity control
Plug & Play power variation
Controller and other electrical components grouped together on the door
Cabled transducer
Fan speed controller
5757
SILENSYS®
INVERTER
57
58 S ILENSYS® INVERTERMHBP
MODELNUMBER Freq.
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling, Mid/Mid
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -35°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Max. current
according to voltage
code
-25° -15° -10° -5° 0° 5° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line TZ
SILAJV9513Z60 986 1724 2176 2688 3261 3901 5308
2429 2.00 26 1650 1.50 5/8" 3/8" 93/110 S 4.830 514 899 1135 1402 1702 2035 2818
SILAJV4517Z60 1061 1871 2336 2848 3413 4042 5697
2459 1.86 27 1650 2.35 5/8" 3/8" 92/110 S 5.130 583 1049 1326 1636 1982 2370 3294
SILFHV4524Z60 1457 2717 3458 4280 5191 6199 8808
3624 1.80 35 2700 2.35 5/8" 1/2" 74/95 M 9.130 800 1524 1968 2468 3025 3639 5060
SILFHV4531Z60 1982 3499 4353 5294 6342 7521 10701
4599 1.82 45 2700 3.90 7/8" 1/2" 78/93 M 10.430 1097 1985 2512 3100 3755 4485 6214
SILFHV4540Z60 2680 4573 5627 6752 7951 9230 12442
5964 1.75* 40 2700 6.00 7/8" 1/2" 101/116 M 14.130 1489 2612 3265 3985 4776 5646 7675
SILAGV4546Z60 2568 4798 6112 7558 9142 10872 15284
6403 1.83* 46 5940 6.00 7/8" 1/2" 133/148 L 14.630 1412 2708 3508 4412 5426 6555 9213
SILAGV4553Z60 3098 5698 7212 8875 10694 12684 17773
7544 1.90* 47 5940 6.00 7/8" 5/8" 150/166 L 16.430 1706 3219 4142 5182 6343 7635 10665
SILAGV4568Z60 4407 7529 9328 11302 13470 15858 22079
9842 2.01* 43 5940 6.00 1"1/8 5/8" 133/148 L 20.230 2447 4294 5416 6678 8093 9673 13424
SILSHV4610V60 8936 13816 16615 19747 23866 25428
na 18252 2.45* na 5000 12.00 1"3/8 7/8" 260/280 XL 20.030 4964 7676 9231 10970 13259 14126
Silensys® Inverter
Statement of the seasonal COP / na: not applicable
R452A
MHBP
MODELNUMBER Freq.
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco. P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Max. current
according to voltage
code
-25° -15° -10° -5° 0° 5° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line TZ
SILAJV9513Z60 959 1676 2107 2591 3129 3728 5141 2312 1.77
26 1650 1.50 5/8" 3/8" 93/110 S 4.830 524 931 1184 1472 1797 2162 2973 1288 2.10
SILAJV4517Z60 1146 1940 2405 2924 3504 4156 5728 2648 1.61
27 1650 2.35 5/8" 3/8" 92/110 S 5.130 629 1083 1358 1668 2016 2404 3264 1481 1.85
SILFHV4524Z60 1485 2705 3427 4233 5127 6122 8474 3787 1.59
35 2700 2.35 5/8" 1/2" 74/95 M 9.130 815 1511 1943 2431 2975 3578 4883 2124 1.77
SILFHV4531Z60 2031 3493 4326 5246 6271 7424 10236 4795 1.61
45 2700 3.90 7/8" 1/2" 78/93 M 10.330 1126 1975 2487 3059 3697 4406 5961 2722 1.96
SILFHV4540Z60 2717 4539 5574 6684 7868 9126 11915 6182 1.72
40 2700 3.90 7/8" 1/2" 95/116 M 10.430 1506 2582 3220 3925 4698 5541 7329 3525 2.12
SILAGV4546Z60 2654 4846 6159 7607 9187 10899 14774 6804
2.46* 46 5940 6.00 7/8" 1/2" 133/148 L 14.630 1458 2723 3518 4417 5421 6529 8916 3843
SILAGV4553Z60 3203 5731 7239 8907 10735 12732 17309 7981
2.57* 47 5940 6.00 7/8" 5/8" 150/166 L 16.430 1762 3223 4138 5174 6331 7613 10390 4512
SILAGV4568Z60 4768 7516 9229 11152 13274 15590 20845 10214
2.77* 43 5940 6.00 1"1/8 5/8" 133/148 L 20.230 2657 4278 5347 6573 7947 9462 12671 5841
SILSHV4610Z60 9469 14769 17352 19899 22425 24953 na 18303
3.63* na 5000 12.00 1"3/8 7/8" 260/281 XL 20.030 5214 8409 10342 12510 14919 17580 23262 10757
Silensys® Inverter
Statement of the seasonal COP / na: not applicable
R404A
For information, the cooling capacity of fluids R449A and R448A: at the evaporation point To = -30°C, SH10K, apply the multiplier ratio 0.94 to the cooling capacities read with R404A.
59
MHBP
MHBP
MODEL NUMBER Freq.
REFRIGERATION OUTPUT32° amb., 10K superheating, 3K subcooling
Evaporation temperature (°C):
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Max. current
according to voltage
code
-15° -10° -5° 0° 5° 10° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line TZ
SILAJV4492Y60 1095 1438 1825 2258 2743 3285 3886 1557 1.92
26 1650 1.50 1/2" 3/8" 90/107 S 3.130 592 781 999 1246 1529 1850 2213 844 2.12
SILAJV4511Y60 1435 1819 2252 2734 3273 3870 4527 1974 1.74
27 1650 1.50 5/8" 3/8" 91/108 S 4.230 784 1002 1253 1536 1856 2218 2621 1084 1.99
SILFHV4518Y60 2063 2641 3321 4113 5030 6088 7299 2867 1.77
33 2700 2.35 5/8" 3/8" 85/106 M 5.830 1127 1458 1850 2311 2849 3470 4180 1575 1.98
SILFHV4525Y60 2822 3530 4329 5227 6241 7386 8678 3846 2.11
40 2700 2.35 5/8" 3/8" 71/92 M 8.530 1559 1972 2446 2986 3603 4304 5099 2137 2.41
SILAGV4534Y60 3236 4364 5691 7178 8792 10502 12263 4738 2.01
40 2970 3.90 7/8" 1/2" 82/103 M 11.130 1757 2393 3154 4023 4988 6031 7134 2588 2.36
SILAGV4543Y60 4030 5279 6829 8626 10630 12795 15068 5729
3.13* 40 2700 3.90 7/8" 1/2" 85/106 M 11.330 2191 2897 3788 4842 6041 7366 8792 3133
Silensys® Inverter
Statement of the seasonal COP
Silensys® Inverter
MODEL NUMBER Freq.
PRODUCTION FRIGORIFIQUE32° amb., 10K surchauffe, 3K sous-ref.
Température d’évaporation (°C) :
REFRIG. OUTPUT EN13215
Evap. T -10°CAco.
P db(A)
Air flow m3/h
Liq. Rec. Vol.
Diam. for tubing O.D.
Net/Gross weight
kg
No. Dim
Max. current
according to voltage
code
-15° -10° -5° 0° 5° 10° 15° Perf.(W)
COP(W/W) Suc. Liqu.
Line TZ
SILAJV4492Y60 1015 1359 1747 2182 2666 3204 3798 1454 1.91
26 1650 1.50 1/2" 3/8" 90/107 S 3.130 549 738 956 1204 1486 1804 2163 788 2.11
SILAJV4511Y60 1331 1719 2155 2642 3181 3774 4425 1843 1.73
27 1650 1.50 5/8" 3/8" 91/108 S 4.230 727 947 1199 1484 1804 2163 2562 1012 1.98
SILFHV4518Y60 1913 2495 3179 3974 4889 5938 7134 2677 1.76
33 2700 2.35 5/8" 3/8" 85/106 M 5.830 1045 1377 1771 2233 2769 3384 4086 1471 1.97
SILFHV4525Y60 2617 3335 4143 5050 6066 7204 8482 3591 2.10
40 2700 2.35 5/8" 3/8" 71/92 M 8.530 1446 1863 2341 2885 3502 4198 4984 1995 2.40
SILAGV4534Y60 3001 4123 5447 6935 8546 10243 11986 4424 2.00
40 2970 3.90 7/8" 1/2" 82/103 M 11.130 1629 2261 3019 3887 4848 5882 6973 2417 2.35
SILAGV4543Y60 3737 4987 6536 8334 10332 12479 14728 5349
3.11 40 2700 3.90 7/8" 1/2" 85/106 M 11.330 2032 2737 3626 4678 5872 7184 8593 2925
R134a
R513A
60 S ILENSYS® INVERTER
SIZE S SIZE M
SIZE L SIZE XL
A
C
A
C
B
A
C
B
B
A
C
B
A B C
S 942 654 837
M 1174 654 837
L 1209 654 1465
XL 1666 654 1457
DIMENSIONSSilensys® Inverter
61
APPLICATION WINDOWSMHBP R452A R404A
MODEL NUMBER
SIL AJV 4517 Z
MHBP R134a R513A
MODEL NUMBER
SIL AJV 9513 Z
SIL AGV 4553 Z
MODEL NUMBER
SIL FHV 4524 Z
SIL FHV 4531 Z
SIL AGV 4546 Z
SIL AGV 4568 Z
MODEL NUMBER
SIL FHV 4540 Z
MODÈLE
SIL SHV 4610 Z
MODEL NUMBER
SIL AJV 4492 Y
SIL AGV 4543 Y
MODEL NUMBER
SIL AJV 4511 Y
SIL FHV 4518 Y
SIL AGV 4534 Y
MODEL NUMBER
SIL FHV 4525 Y
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +15
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +10 +15
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +5 +15
38
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 0 +15
32
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 -5 +15
32
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +10 +15
Amb
T. (°
C)
Evap T. (°C)
46
43
-25 -20 +5 +15
38Am
b T.
(°C)
Evap T. (°C)
46
43
-25 -20 0 +15
32
62 RACK TRIO QUATTRO AND INFINEE®
RACK TRIO-QUATTRO ................................................................... 64
INFINEE® ...................................................................................... 66
63
RACK trio Quattroand INFINEE®
63
64 RACK TRIO QUATTRO AND INFINEE®
CHARACTERISTICS
REFRIGERATION►AJ² or FH compressors with identical power►Oil balancing►Oil separator coalescing
CONDENSINGVersion with condenser (Type A) including:►Aluminium micro-channel exchanger►Variable speed fans►Receiver which can be isolated►Housing as an accessory
Version without condenser (Type B):►More compact (629 mm deep)
ELECTRICAL CABINET►Regulation цRack: - Manages the capacity staging - Ensures operating safety►High pressure regulation sensor►Contactors and circuit breakers provided
The Rack Trio-Quattro range is a new generation of refrigeration plant.This Rack range can supply several evaporation units and has stand-alone regulation.
Power modulation systemRACK TRIO QUATTRO
IN SHORT…►R134a/R513A or R452A/R449A/R448A/R404A refrigerants ►3 or 4 compressor stages►Version availabe with air condenser or without condenser ►Integrated regulation
POSITIVEREFRIGERATION
from 3.4 to 15.9 kW
65
APPLICATIONSInstallation with several indoor units:
CUSTOMER BENEFITS►Multiple evaporation units: capacity modulation►Reliability: oil recovery and integrated regulation►Adaptability: with or without condenser
NEW
66 RACK TRIO QUATTRO AND INFINEE®
CHARACTERISTICSREFRIGERATION►Semi-hermetic compressor ►Compressor inverter frequence of 25 to 85 Hz i.e. 7.4 to 20.5 kW►Electronic temperature and pressure sensor►Electronic pressure relief valve►Ventilation with electronic commutation
HYDRAULICS►Pump on inverter to maintain a constant delta T►Electronic pressure and temperature sensor►Strainer which can be isolated by valves►Expansion tank
ELECTRONICS►Full and communicating regulation (Tecumseh software)►Class B residential CEM emissions filter (EN 61000-6-3)
* Global Warming Potential
Capacity variation: from 7.4 to 20.5 kWAmbient temperature 35°C water condition -4°C/-8°C 35% Glycol
Water chiller for refrigeration, environmentally-friendlyINFINEE®
IN SHORT…► R290 refrigerant sustainable (GWP* = 3) and very efficient solution ► Optimized for negative operation: water outlet temperature down to -10°C► 100% inverter: compressor, pump and ventilation►Plug and Play
67
NEW
APPLICATIONS
CUSTOMER BENEFITS►Chilled water easy to handle► Efficiency of R290 and the 100% Inverter
design: especially with partial loads► Reliability: redundancy possible with
chillers in parallel► Sustainability: water and propane have
a guaranteed future
Freq. comp.(Hertz)
Cold power (kW)
Refrigeration COP
Flow of water + Glycol (m3/h)
Machine COP
25 7.42 2.64 1.71 1.92
30 8.69 2.60 2.01 1.98
35 9.94 2.55 2.29 2.01
40 11.1 2.50 2.57 2.02
45 12.3 2.44 2.84 2.02
50 13.5 2.39 3.11 2.01
55 14.6 2.33 3.36 1.99
60 15.6 2.27 3.61 1.97
65 16.7 2.22 3.85 1.94
70 17.7 2.16 4.08 1.91
75 18.6 2.10 4.30 1.88
80 19.6 2.05 4.52 1.85
85 20.5 2.00 4.72 1.81
COOLING CAPACITY
Negative temperature water for small shops such as bakeries, service stations, groceries…Positive temperature water for water-cooled condensing units, Transcritical CO2 units…
Ambient T° 35°C/Output T° -8°C
68 TOOLS68 TOOLS
69
TOOLS
70 TOOLS
COMPLETE AND EFFECTIVE SELECTION SOFTWARE
► Selection of the compressor and/or condensing unit according to several parameters: cool-ing capacity, voltage, refrigerant, compressor technology, and according to different modes governed by standards: EN, ARI, CECOMAF etc. or customised conditions (operating pressure, gas return, useful superheating, subcooling, etc.)
► Performance data and polynomials for refrigerants R452A, R448A/R449A, R513A, R1234yf and R290
► Selection of the designation of the model according to the dew point temperature or mean temperature
► Notification of new models► Obsolete models identified in a specific tab► Access to the documentation available: technical sheets, acoustic spectrum, electrical draw-
ings, layout, installation instructions, photo, 3D model► Use of the data made easier by export to Excel and Open Office► Automatic update► Available in 7 languages► Network installation possible
VERSION 4.5 - January 2019 Download the selection software now, available on the website: www.tecumseh.com
TOOLS
SELECT
71
THE CROSS REF SOFTWARE
An ergonomic and functional tool allowing you to determine the equivalent Tecumseh compressor from a competing model.
An obsolete refrigerant? A Tecumseh model to replace that of a competitor? The Cross Ref software is here to help.
REPLACE
https://www.tecumseh.com/fr/Europe/Cross-Reference-Tool
FOLLOW USON
TECUMSEHEUROPE&AFRICA
WWW.TECUMSEH.COM
T E C U M S E H E U R O P E2, avenue Blaise Pascal, 38080 Vaulx-Milieu, France.
PHONE : +33 (0)4 74 82 24 00
EMAIL : [email protected]
© 2019 Tecumseh Products Company. All rights reserved. Note: in a constant effort to improve, Tecumseh Europe reserves the right to change the data contained in this document without prior notice.