Electric Equipment
MCB / MC&TOR / MMS / MCCB / ACB / FDB / SMDB / VCB
LS Industrial Systems Electric Products
-
?1, 2, 3 and 4 pole series up to 125AF
?B, C and D Characteristics
?2 and 4 pole series up to 100AF
?Sensitivity up to 300mA
?Overcurrent protection type available
Metasol series
?3 and 4 pole series up to 800AF Mini-contactors available
?AC/DC common use coil from 100AF
?Thermal (Bimetallic) and electronic type overload relays are available
?CE marked and UL approved
Page 4
Page 8
Page 6
Page 22
Page 12
Page 20
Page 21
-
Susol/Metasol series
? 2, 3 and 4 pole series up to 800AF
?Rated ambient temperature at 40? calibrated for 50? available?CE marked according to IEC standard and UL approved MCCBs are also available.
Metasol series
? 2, 3 and 4 pole series up to 800AF
?CE marked according to IEC standard
Susol/Metasol series
?65, 85 and 150kA breaking capacity
?High functional digital trip relays
?CE marked and Marine classiflcation
Susol series
Page 24
Page 30
Page 34
Page 40
Page 44
Page 48
-
4Miniature circuit breakers1, 2, 3 and 4 pole series up to 125AF
Drawing 2 : Type BKN-b
17.8
(33)
(19)
4537
5 43.8
6860
65 82
Drawing 3 : Type BKHDrawing 1 : Type BKN & BKN-c
5
37
45
60
(14)
45
17.8
63
68
82
6kA at 230/400VAC
10kA at 400VAC
10kA at 230/400VAC
1 changeover contact6A at 240VAC, 3A at 415VAC(AX)6A at 230VAC, 3A at 415VAC(AL)2A at 48VDC, 1A at 125VDCLug terminalCable capacity 2.5mm29mm wide
1 changeover contact6A at 240VAC, 3A at 415VAC(AX/AL)6A at 24VDC, 2A at 48VDC, 1A at 130VDCLug terminalcable capacity 0.75~2.5?8.8mm wide
Auxiliary switch, AXOptional
Protection Overload and short circuit Overload and short circuitRated current 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63ACharacteristic B, C, D curve B, C, D curvePoles 1p, 1p+N, 2p, 3p, 3p+N, 4p 1p, 1p+N, 2p, 3p, 3p+N, 4pBreaking capacity 1pole 2~4pole 1pole 2~4pole
Standard IEC 60898/60947-2 IEC 60898/60947-2Type of trip Thermal magnetic release Thermal magnetic releaseElectrical endurance 6000 operations 8000 operationsMount On 35mm DIN rail On 35mm DIN railWidth 17.8mm per pole 17.8mm per poleTerminal Lug type(cable up to 25mm2) Dual type(Lug & Screw) Lug type(cable up to 25mm2)
Dimension See page 1 See page 2Characteristic curve See curve 1 See curve 1
1A2A3A4A6A10A16A20A25A32A40A50A63A80A100A125A
BKN-bBKN BKN-cType
6kA at400VAC
-
5Drawing 4 : Type BKP
17.8
8.9
60
82
60
37
455
45
68
(22)
(22)
(17)
Drawing 5 : Type BFN
75
63
6065
56
75
81
23.5
Curve 1 : Type BKP, BKN, BKN-b, BKH, RKP
Curve 2 : Type BFN
10kA at 220/240VAC
10kA at 230/400VAC
10kA at 400VAC
Overload and short circuit Overload and short circuit Overload and short circuit63, 80, 100A, 125A 3, 6, 10, 16, 20, 25, 32A 5, 10, 15, 20, 30, 40, 50AC, D curve B, C, D curve 1P, 2P, 3P1p, 2p, 3p, 3p+N, 4p 1p+N 1P, 2P, 3P1pole 2~4pole
IEC 60947-2 IEC 60898 IEC 60947-2Thermal magnetic release Thermal magnetic release Thermal magnetic release6000 operations 20000 operations 10, 000 operationsOn 35mm DIN rail On 35mm DIN rail Plug-in27mm per pole 17.8mm per pole 25mm per poleLug type(cable up to 50mm2) Lug type(cable up to 10mm2) Lug type (14-6 AWG.)
See page 3 See page 4 See page 5See curve 1 See curve 1 See curve 2
BKH BKP BFN
4.5kA at 230VAC
-
6Residual current circuit breakers 2 and 4 pole series up to 63AF
Drawing 1 : Type RKP
35.6
8.9
82
60
45
60
5
(22)
68
37
(22)
(17)
45
70
Drawing 6 : Type RKS-b
35
27
20 21
2223
45111
81
24
5019
7818
Drawing 2 : Type RKN
5
61
74
(13)
45
36
45
22
72
68
82
36
68
82
1 3 5 N
2
1
24 6 N
N
N
Drawing 7 : Type RKN-b
42.273.5
59.8
108
42.7
21
22
23
54
Drawing 5 : Type RKS
55
23
18
18
Type RKP RKS RKS-b RKN RKN-b
Protection Ground fault and overcurrent Ground fault and overcurrent Ground fault Ground faultRated current, In 3(C,D),6,10,16,20,25,32A(B,C,D curve) 6, 10, 16, 20, 25, 32A (B, C curve) 25, 32, 40, 63A 25, 32, 40, 63, 100ARated residual current
Operating, I?n 30, 100, 300mA(non-adjustable) 30, 100mA (non-adjustable) 30, 100, 300mA(non-adjustable)Non-operating, I?no 0.5I?n 0.5I?n 0.5I?n
Number of poles 1P+N 1P+N 2, 4 poleRated voltage 230VAC 230VAC 230VAC(2p), 230/400VAC(4p)Residual current off-time ? 0.1 sec. ? 0.3 sec. ? 0.1 sec.Standard IEC 61009 IEC 61009 IEC 61008Type of trip
Ground fault Electro-magnetic Electro-magnetic Electro-magneticOvercurrent Thermal-magnetic Thermal-magnetic N.A
Breaking capacity 4.5kA 10kAConditional short circuit capacity 6kA for In=25, 32, 40, 63A 10kAElectrical endurance 20000 operations ? 4000 operations 6000 operationsMount On 35.6mm DIN rail On 35mm DIN rail On 35mm DIN railWidth 18mm per pole 18mm per pole 18mm per poleTerminal Lug type(cable up to 10?) Lug type(cable up to 10?) Lug type(cable up to 35?)Dimension See drawing 1 See drawing 5 See drawing 6 See drawing 2 See drawing 7Characteristic curve See page 5 (curve 1)
-
7Drawing 3 : Type 32KGRc & 32KGRd
Drawing 4 : Type BKD
37
5
60
70
45
(10)
45
60
17.8
82
Type BKD
Rated current, In 40, 50, 63, 80, 100, 125ANumber of poles 1p, 2p, 3p, 4pRated voltage 240/415VACStandard IEC 60947-3Electrical 40, 50, 63A 20000 operationsendurance 80, 100, 125A 10000 operationsMount On 35mm DIN railWidth 17.8mm per poleTerminal Lug type(cable up to 50?)Dimension See drawing 4
32KGRc 32KGRd
Curve 1 : Type 32KGRc, 32KGRd
Ground fault and overcurrent15, 20, 30A
15, 30mA(non-adjustable)0.5I?n2 pole110/220VAC? 0.03 sec.KS, JIS *(IEC61009)
ElectronicBimetallic1.5kA 2.5kA
6000 operationsOn 35mm DIN rail35mm Screw clamp type(cable up to 25?)See drawing 3See curve 1Note) * IEC61009 standard is applicable for 32KGRa only.
-
8Surge Protective DeviceBKS Series Din-rail type
Product description
Product rating
The BKS surge protective device is applied to the alternating current 50/60Hz, 220V/380V power system and provides the protection fromthe surge overvoltage of an electric system.Moreover, it is the protection element (MOV) replacement type and is the product with convenience and economic efficiency. However, only the protection module is provided so that separate components have to be combined according to the site conditions.If the protective device is normal, the display becomes green. The display becomes red after operation (abnormal or after an accident).
Type BKS-A BKS-B BKS-C BKS-D BKS-E
Pole 1, 2, 3, 4 Pole Rated system voltage Un (Applied Voltage) AC 220V AC 220V AC 220V AC 380V AC 380V Maximum continuous operating voltage Uc
AC 320 AC 320V AC 320V AC 420V AC 460V (MCOV, The voltage applied to the surge protective device)
Voltage protection level Up 1.0kA 1.2kA 1.5kA 2.0kA 2.3kA(The voltage level with the surge suppressed)
Maximum discharge current Imax(8/20?) kA 10kA 20kA 40kA 60kA 70kAResponse time ns < 25 ns Usable ambient temperature ? -40 ~ +80?Usable frequency Hz 50/60 HzAttachment type DIN-rail attachment typeOperation status indication window Normal operation: Green, Abnormal/After an accident: RedProduct color and shape
Min. terminal connection (mm2) 1 Phase and Neutral 2.5, Earth 4Protection class Class? Class?Alarm Contact No No No No No
Operation statedisplay window
The MOV system unitcan be replaced.
Terminal part with thewire fastened
* The surge protective device starts to operate above the maximum continuous operating voltage Uc (MCOV).
MOV System unit
DIN-rail mounting bed
Common bar
Drawing
-
9SP SeriesBox type
The SP series surge protective device is applied to the alternating current 50/60Hz, 220V/380V power system and provides the protectionfrom the surge overvoltage of an electric system. Moreover, the protection module, disconnectable device (fuse), and fastened power and ground wires are organized into the all-in-one steelcabinet with convenient installation and stability.If the protective device is normal, the display becomes green. The display becomes red after operation (abnormal or after an accident).
Product rating-Single phase 2W+G (SPL)Type SPL-110S 20kA SPL-220S 40kA SPL-220S 80kA
Pole 2W+G 2W+G 2W+GRated system voltage Un (Applied Voltage) AC 110V/220V AC 220V AC 220VMaximum continuous operating voltage Uc AC 320V AC 320V AC 320V(MCOV, The voltage applied to the surge protective device)
Voltage protection level Up 1.5kV 1.5kV 1.5kV (The voltage level with the surge suppressed)Maximum discharge current Imax(8/20?) kA 20kA 40kA 80kA Response time ns < 5 ns Usable ambient temperature ? -40 ~ +70?Usable frequency Hz 50/60 HzAttachment type Screw attachment typeOperation status indication window Normal operation: Green LED lighting, Abnormal/After an accident: Red lightingDimension(W?H?D) 60?87?47 68?90?70 95?117?68Product color and shape
Protection class Class? Class?/ Class? Class?/ Class?
-
10
Surge Protective DeviceSP SeriesBox type
Product rating-Three phase 3W+G (SPT) AC 380VType SPT-380S 40kA SPT-380S 80kA SPT-380S 120kA SPT-380S 160kA
Pole 3W+G 3W+G 3W+G 3W+GRated system voltage Un (Applied Voltage) AC 380V AC 380V AC 380V AC 380VMaximum continuous operating voltage Uc AC 320V AC 320V AC 320V AC 320V(MCOV, The voltage applied to the surge protective device)
Voltage protection level Up 2.0kV 2.0kV 2.0kV 2.0kV (The voltage level with the surge suppressed)Maximum discharge current Imax(8/20?) kA 40kA 80kA 120kA 160kAResponse time ns < 5 ns Usable ambient temperature ? -40 ~ +70?Usable frequency Hz 50/60 HzAttachment type Screw attachment typeOperation status indication window Normal operation: Green LED lighting, Abnormal/After an accident: Red lightingDimension(W?H?D) 113?160?80 130?160?80 160?190?86 160?190?86Product color and shape
Protection class Class?/ Class? Class?/ Class?/ Class?
Product rating-Three phase 3W+G (SPT) AC 440VType SPT-440S 40kA SPT-440S 80kA SPT-440S 120kA SPT-440S 160kA
Pole 3W+G 3W+G 3W+G 3W+GRated system voltage Un (Applied Voltage) AC 440V AC 440V AC 440V AC 440VMaximum continuous operating voltage Uc AC 320V AC 320V AC 320V AC 320V(MCOV, The voltage applied to the surge protective device)
Voltage protection level Up 2.0kV 2.0kV 2.0kV 2.0kV (The voltage level with the surge suppressed)Maximum discharge current Imax(8/20?) kA 40kA 80kA 120kA 160kAResponse time ns < 5 ns Usable ambient temperature ? -40 ~ +70?Usable frequency Hz 50/60 HzAttachment type Screw attachment typeOperation status indication window Normal operation: Green LED lighting, Abnormal/After an accident: Red lightingDimension(W?H?D) 113?160?80 130?160?80 160?190?86 160?190?86Product color and shape
Protection class Class?/ Class? Class?/ Class?/ Class?
-
11
Product rating-Three phase 4W+G (SPY)Type SPY-220S 40kA SPY-220S 80kA SPY-220S 120kA
SPY-220S
160, 200, 240kA
Pole 4W+G 4W+G 4W+G 4W+GRated system voltage Un (Applied Voltage) AC 220/380V AC 220/380V AC 220/380V AC 220/380VMaximum continuous operating voltage Uc AC 320V AC 320V AC 320V AC 320V(MCOV, The voltage applied to the surge protective device)
Voltage protection level Up 2.0kV 2.0kV 2.0kV 2.0kV (The voltage level with the surge suppressed)Maximum discharge current Imax(8/20?) kA 40kA 80kA 120kA 160, 200, 240kA Response time ns < 5 ns Usable ambient temperature ? -40 ~ +70?Usable frequency Hz 50/60 HzAttachment type Screw attachment typeOperation status indication window Normal operation: Green LED lighting, Abnormal/After an accident: Red lightingDimension(W?H?D) 130?160?80 130?160?80 160?190?86 160?190?86Product color and shape
Protection class Class?/ Class? Class?/ Class?/ Class?
-
12
Contactors & Overload relaysMetasol MC 18 to 100A
MC type
Thermal Overload RelaysMT type
Magnetic Contactors
* The safety cover of magnetic contactor and thermal overload relay is optional.
MT-12/??
690V690V6kV
10A, 200.1~18A
0.17
45?73.2?63.7
TypeScrews clamp terminals
Rated operational voltage, UeRated insulation voltage, UiRated impulse withstand voltage, UimpTrip classSetting rangeSize
Weight kgand weight Size(W?H?D) mm
? ?
?
MC-6a MC-9a MC-12a MC-18a? ? ? ?
3pole690V690V
50/60Hz6kV
1800 operations per hour15 mil. operations 2.5 mil. operations
25 25 25 322.5 2.5 3.5 4.59 11 13 183 4 5.5 7.57 9 12 183 4 7.5 7.56 7 12 133 4 7.5 7.54 6 9 9
1.5 1.5 2.2 3.77 8 11 16
2.2 2.2 4 45 6 9 11
0.3345?73.5?82
0.4745?83?113.7
1a or 1bUA-1
AU-2, AU-4
18AF
Note) Minimum conduct current of Auxiliary contactor is DC 17V 5mA.
Typescrews clamp terminals
Number of polesRated operational voltage, UeRated insulation voltage, UiRated frequencyRated impulse withstand voltage, UimpMaximum operating rate in operating cycles per hour(AC3)Durability Mechanical
ElectricalCurrent AC-1, Thermal current Aand AC-3 200/240V kWpower A
380/440V kWA
500/550V kWA
690V kWA
AC-4 200/240V kWA
380/440V kWA
Size AC Weight kgand control Size(W?H?D) mmweight DC Weight kg
control Size(W?H?D) mmAuxiliary(standard)Auxiliary Side mount
Front mount
Frame size
? ?
?
MT-32/??
690V690V6kV
10A, 200.1~40A
0.17
45?75?90
MC-9b MC-12b MC-18b MC-22b*? ? ? ?
3pole690V690V
50/60Hz6kV
1800 operations per hour15 mil. operations 2.5 mil. operations
25 25 32 402.5 3.5 4.5 5.511 13 18 224 5.5 7.5 119 12 18 224 7.5 7.5 157 12 13 20 4 7.5 7.5 156 9 9 18
1.5 2.2 3.7 3.78 11 16 18
2.2 4 4 5.56 9 11 13
0.4645?73.5?86
0.4745?73.5?117.7
1a1bUA-1
AU-2, AU-4
22AF
-
13
MT-95/??
690V690V6kV
10A, 207~100A
0.48/0.5
70?97?110
MT-63/??
690V690V6kV
10A, 204~65A
0.31/0.33
55?81?100
100AFMC-50a MC-65a? ?
3pole690V1000V
50/60Hz8kV
1800 operations per hour12 mil. operations 2 mil. operations
70 10015 18.555 6522 3050 6530 3343 6030 3328 357.5 1135 5015 2232 47
1.0579?106?122
1.379?106?149
2a2bUA-1
AU-2, AU-4
65AF
MT-32/??
690V690V6kV
10A, 200.1~40A
0.17
45?75?90
MC-32a MC-40a? ?
3pole690V1000V
50/60Hz8kV
1800 operations per hour12 mil. operations 2 mil. operations
50 607.5 1132 4015 18.532 40
18.5 2228 32
18.5 2220 234.5 5.520 257.5 1117 24
0.5569?83?93
0.7769?83?120
2a2bUA-1
AU-2, AU-4
40AFMC-75a MC-85a MC-100a? ? ?
3pole690V1000V
50/60Hz8kV
1800 operations per hour12 mil. operations 2 mil. operations
110 135 16022 25 3075 85 10537 45 5575 85 10537 45 5564 75 8537 45 4542 45 6513 15 1955 65 8025 30 3752 62 75
1.9394?140?137
2.894?140?174
2a2bUA-1
AU-2, AU-4
-
14
Contactors & Overload relaysMetasol MC 4P 150 to 800A
MC type
Thermal Overload RelaysMT type
Magnetic Contactors
MT-150/??
690V690V6kV
10A, 2034~150A
0.67
95?109?113
TypeScrews clamp terminals
Rated operational voltage, UeRated insulation voltage, UiRated impulse withstand voltage, UimpTrip classSetting rangeSize
Weight kgand weight Size(W?H?D) mm
? ?
?
MC-130a MC-150a? ?
3pole690V1000V
50/60Hz8kV
1200 operations per hour5 mil. operations1 mil. operations
160 21037 45130 15060 75120 15060 7590 10055 5560 6022 3093 12045 5590 110
2.195?158?132
2.195?158?132
UA-1AU-2, AU-4
150AFType
screws clamp terminalsNumber of polesRated operational voltage, UeRated insulation voltage, UiRated frequencyRated impulse withstand voltage, UimpMaximum operating rate in operating cycles per hour(AC3)Durability Mechanical
ElectricalCurrent AC-1, Thermal current Aand AC-3 200/240V kWpower A
380/440V kWA
500/550V kWA
690V kWA
AC-4 200/240V kWA
380/440V kWA
Size AC Weight kgand control Size(W?H?D) mmweight DC Weight kg
control Size(W?H?D) mmAuxiliary(standard)Auxiliary Side mount
Front mount
Frame size
? ?
?
MT-225/??
690V690V6kV
10A, 2065~240A
2.5
147?141?184
MC-185a MC-225a? ?
3pole690V1000V
50/60Hz8kV
1200 operations per hour5 mil. operations1 mil. operations
230 27555 75185 22590 110185 225110 132180 200110 140120 15037 45150 18075 90150 180
5.4138?203?181
AU-100 (Max.4NO4NC)
225AF
-
15
MT-400/??
690V690V6kV
10A, 2085~400A
2.6
151?171?198
400AFMC-265a MC-330a MC-400a? ? ?
3pole690V1000V
50/60Hz8kV
1200 operations per hour5 mil. operations 2.5 mil. operations 1 mil. operations 0.5 mil. operations
300 350 45080 90 125265 330 400132 150 200265 330 400140 160 200225 280 350160 200 250185 225 30050 55 75200 220 300102 110 150200 220 300
9.2163?243?198
AU-100 (Max.4NO4NC)
MT-800/??
690V690V6kV
10A, 20200~800A
11.5
360?530?212
800AFMC-500a MC-630a MC-800a? ? ?
3pole690V1000V
50/60Hz8kV
1200 operations per hour2.5 mil. operations0.5 mil. operations
580 660 900147 190 220500 630 800250 300 400500 630 800250 300 400400 500 720300 400 500380 420 63090 110 160350 400 630176 200 300350 400 630
22.4285?312?242
AU-100 (Max.4NO4NC)
-
16
Contactors & Overload relaysMetasol MC 4P 18 to 85A
MC typeMagnetic Contactors
18AFFrame size
? ?
?
MC-6a/4 MC-9a/4 MC-12a/4 MC-18a/4?
4pole690V690V
50/60Hz6kV
1800 operations per hour15 mil. Operations
0.5 mil. Operations 0.8 mil. Operations25 25 25 409 9 9 1525 25 25 4017 17 17 2725 25 25 4021 21 21 3525 25 25 4027 27 27 4425 25 25 4025 25 25 320.5 0.5 0.75 11.5 1.5 2 32 2 3 53 3 5 7.55 5 7.5 10
7.5 7.5 10 1500 00 0 0
0.3345?73.5? 79
0.545?73.5?110.7
-
UA-1AU-2, AU-4
TypeScrew clamp terminal
Number of polesRated operational voltage (Ue)Rated insulation voltage (Ui)Rated frequencyRated impulse withstand voltage, UimpMaximum operating rate in operating cycles per hour(AC1)Durability Mechanical
ElectricalCurrent Thermal current Aand AC-1 200/240V kWPower A
380/400V kWA
500/550V kWA
690V kWA
UL rating Continuous current A(50/60Hz) Single 110~120V HP
Phase 220~240V HP200~208V HP
Three 220~240V HPPhase 440~480V HP
550~600V HPNEMA Size
Size AC Weight kgand Control Size(W?H?D) mmweight DC Weight kg
Control Size(W?H?D) mmAuxiliary(standard)Auxiliary Side Mount
Front Mount
-
17
MC-22a/4?
4pole690V690V
50/60Hz6kV
1800 operations 15 mil. Operations1 mil. Operations
4015402740354044403223
7.57.510151
0.447.2?80?86.8
0.547.2?80?113.2
-
AU-1AU-2, AU-4
22AF
MC-50a/4 MC-65a/4 MC-75a/4 MC-85a/4?
4pole690V1000V
50/60Hz8kV
1800 operations per hour12 mil. Operations1 mil. Operations
80 100 110 13530 37 41 5180 100 110 13556 70 76 9580 100 110 13570 88 97 12080 100 110 13588 110 120 15080 100 110 13570 80 90 1003 5 5 7.5
7.5 10 15 1510 15 20 2515 20 25 3030 40 50 5030 40 50 502 2 2 3
1.291?123.5?117.8
1.2991?123.5?117.8
-
AU-1AU-2, AU-4
85AF
MC-32a/4 MC-40a/4?
4pole690V690V
50/60Hz6kV
1800 operations per hour15 mil. Operations1 mil. Operations
50 6018 2250 6035 4250 6043 5250 6055 6650 6045 502 35 5
7.5 1010 1020 2520 251 1
0.5959?83.5?94.5
0.759?83.5?121
-
AU-1
40AF
-
18
Contactors & Overload relaysMetasol MC 225 to 800A
MC typeMagnetic Contactors
225AF
MC-100a/4 MC-130a/4 MC-150a/4 MC-185a/4 MC-225a/4?
4pole690V1000V
50/60Hz8kV
1200 operations per hour15 mil. Operations0.8 mil. Operations
160 165 250 300 33057 60 76 87 100150 155 200 230 260106 110 142 165 185150 155 200 230 260132 137 180 205 230150 155 200 230 260165 170 225 255 290150 155 200 230 260160 160 210 230 2757.5 10 15 15 1515 20 25 30 4030 40 40 60 6030 40 50 60 7560 75 100 125 15060 75 100 125 1503 3 4 4 4
5.6175?203?185
2a2bAU-100
-
* - FLA = 722 A, LRA = 5618 A** - FLA = 566 A, LRA = 4495 A
Frame size
? ?
?
TypeScrew clamp terminal
Number of polesRated operational voltage (Ue)Rated insulation voltage (Ui)Rated frequencyRated impulse withstand voltage, UimpMaximum operating rate in operating cycles per hour(AC1)Durability Mechanical
ElectricalCurrent Thermal current Aand AC-1 200/240V kWPower A
380/400V kWA
500/550V kWA
690V kWA
UL rating Continuous current A(50/60Hz) Single 110~120V HP
Phase 220~240V HP200~208V HP
Three 220~240V HPPhase 440~480V HP
550~600V HPNEMA Size
Size AC Weight kgand Control Size(W?H?D) mmweight DC Weight kg
Control Size(W?H?D) mmAuxiliary(standard)Auxiliary Side Mount
Front Mount
-
19
400AF
MC-265a/4 MC-330a/4 MC-400a/4?
4pole690V1000V
50/60Hz8kV
1200 operations per hour15 mil. Operations0.5 mil. Operations
360 420 500115 135 160300 350 420215 250 300300 350 420265 315 375300 350 420335 390 470300 350 420300 350 450
- - -
- - -
75 100 125100 100 150200 200 300200 200 3005 5 5
9.9206?243?205
2a2bAU-100
-
800AF
MC-500a/4 MC-630a/4 MC-800a/4?
4pole690V1000V
50/60Hz8kV
1200 operations per hour12 mil. Operations0.5 mil. Operations
630 750 900245 255 310630 660 800450 470 570630 660 800560 590 710630 660 800710 740 900630 660 800580 660 900
- - -
- - -
150 200 200200 250 300400 500 600 *400 500 600 **6 6 7
26.3346?310 ?244
2a2bAU-100
-
-
20
Mini contactors6 to 16A
3NO main contacts
1 auxiliary contactsScrew clamp type Fast-on type Cage clamp type Solder pin type
Mini contactors
Overload Relays
Bimetallic style
Type GT
Screw clamp type AC coil GMC-6M GMC-9M GMC-12M GMC-16MDC coil GMD-6M GMD-9M GMD-12M GMD-16M
Fast-on type AC coil GMC-6MF GMC-9MF GMC-12MF GMC-16MFDC coil GMD-6MF GMD-9MF GMD-12MF GMD-16MF
Cage clamp type AC coil GMC-6MC GMC-9MC GMC-12MC GMC-16MCDC coil GMD-6MC GMD-9MC GMD-12MC GMD-16MC
Solder pin type AC coil GMC-6MP GMC-9MP GMC-12MP GMC-16MPDC coil GMD-6MP GMD-9MP GMD-12MP GMD-16MP
Ratings / IEC60947-4 kW A kW A kW A kW AAC1 20 20 20 20AC3 200/240V 1.5 7 2.2 9 3 12 4 15
380/440V 2.2 6 4 9 5.5 12 7.5 16500/550V 3 5 3.7 6 4 7 5.5 9690V 3 4 4 5 4 5 4 5
Ratings / UL508 hp A hp A hp A hp Acontinuous current Ith = 20A (maximum for cage clamp type is 10A)single phase 120V 1/2 1/2 1 * -
230V/240V 1 1.5 2 * * -three phase 240V 1.5 3 3 -
480V 3 5 7.5 * * * -600V 3 5 7.5 -Wire Range : Copper, 75C, Stranded, 18-12AWG
NEMA size 00 00 00 0
Base for separate mountGT-12M
Setting ranges (A)
DifferentialNon-differential (3-heater)Non-differential (2-heater)
GTK-12MGTH-12M/3GTH-12M
0.1 - 0.160.16 - 0.250.25 - 0.40.4 - 0.63
0.63 - 11 - 1.6
1.6 - 2.52.5 - 4
4 - 65 - 86 - 97 - 109 - 13
12 - 16
Frame size 6A 9A 12A 16A
AU-2M
AU-1M
AU-4M
AU-2MF
AU-1MF
AU-4MF
AU-2MC
AU-1MC
AU-4MC AU-1MP
Additional auxiliary contacts
Note) * = 1/2 for cage clamp type, ** = 1.5hp for cage clamp type, *** = 5hp for cage clamp type16AF : not approved from UL
2-pole, Front mount
4-pole, Front mount
2-pole, Side mount
Fast-on type Cage clamp type Solder pin typeScrew clamp type
-
21
Digital motor protection relay
Model No. DMP06-S/Sa DMP60-S/Sa DMP06-T/Ta DMP06-T/Ta
Wiring Screw type Tunnel typePanel mount Unit or Extension Note1)Operation time Select either reverse time characteristics or definite time characteristics Protection Over current According to the setting time
Phase failure 3 sec. Reverse phase Within 0.1 sec. Asymmetry 5 sec.Stall 5 sec.Lock Within 0.5 sec.Under current 3 sec.Ground fault Within 0.05~1 sec. Selectable (0.05~1.0sec)Short circuit Note2) Within 50ms
Alarm Variable (60~110% of the setting current)Current setting range (A) 0.5~6 5~60 0.5~6 5~60Motor capacity 220~240V 0.09~0.75 1.1~11 0.09~0.75 1.1~11 (kW) 380~440V 0.12~1.5 2.2~22 0.09~1.5 2.2~22Time setting Definite Delay in starting 0~60secrange (sec) time Delay in operating 0~30sec
Inverse time 0~60secReset Manual reset
Tolerance Current ?5%Time ?5% (or?0.5sec)
Operating power Voltage AC 190~250V Note3) Frequency 60Hz (50Hz) Aux. contact OL 2-SPST 3A/250Vac Resistive load
AL SPST 3A/250Vac Resistive loadInsulation resistance Over DC500V 100?Surge impulse voltage(IEC1000-4-5) 1.2?50? 6kV (Apply standard wave form)Fast transient burst(IEC1000-4-4) 2.5kV/5minEnvironment Temperature Operation -25~70?
Storage -30~80?Humidity 30~90% RH (No freezing)
Display 7-Segment 3 phase current, cause of a faultBar-Graph 60~110% of real load current
Mounting type 35mm Din-rail/PanelNote1) In extension type, the digital EMPR is calibrated with combining the display past and main body so,
please cautious not to combine the display part and main body with different part No.Note2) Instantaneous short circuit protection is optional Note3) Operational voltage of AC 110V and 50Hz is optional
DMP?-S/Sa DMP?-T/Ta
-
22
Manual motor startersQuick selection table ... IEC rating
220V 220V240V 415V 460V 525V 690V 240V 415V 460V 525V 690V230V 400V 440V 500V 600V 230V 400V 440V 500V 600V
Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics
100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 3 3100 100 100 100 100 100 50 38 3 3100 100 100 100 50 38 15 11 3 3100 100 100 100 15 11 10 8 3 3100 100 100 100 15 11 10 8 3 3100 100 50 38 15 11 6 5 3 3100 100 50 38 10 8 6 5 3 350 38 20 15 10 8 6 5 3 340 30 15 11 8 6 6 5 3 340 30 15 11 8 6 6 5 3 330 22 15 11 6 4 5 4 3 3- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics
100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 8 8100 100 100 100 100 100 100 100 8 8100 100 100 100 100 100 100 100 6 6100 100 100 100 50 38 50 38 6 6100 100 100 100 50 38 50 38 6 6100 100 100 100 50 38 42 32 6 6100 100 50 38 20 15 10 8 4 4100 100 50 38 20 15 10 8 4 4100 100 50 38 20 15 10 8 4 4100 100 50 38 20 15 10 8 4 4- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
0.160.250.40.63
11.62.54681013172226324050637590100
Type Current adjustable type MMS-32S MMS-32HInstantaneous type - MMS-32HIBreaking capacity Standard High breakingHandle Type Toggle Rotary
Number of poles 3 3Rated operational voltage (Ue) Up to 690V Up to 690VRated frequency 50/60 Hz 50/60 HzRated insulation voltage (Ui) 690V 690VRated impulse voltage (Uimp) 6kV 6kVUtilization category IEC 60 947-2 (Breaker) Cat. A Cat. A
IEC 60 947-4 (Motor starter) AC 3 AC 3Mechanical endurance (Operating) 100,000 100,000Electrical endurance (Cycles) 100,000 100,000Max operating frequency per hour (Ope./h) 25 25Temperature compensation (Operation) -20 ~ +60? -20 ~ +60?Instantaneous short circuit release 13 ? Ie max. 13 ? Ie max.Overload protection ? ?Phase failure function ? ?Trip indicating function ? ?Test function ? ?Dimension(W?H?D) 45?105?54.4 45?105?60.3Weight (g) 320 360Rated Rated Thermal releasebreaking
operational Adjustmentcapacity
current (Ie)range
(kA) (A)0.1~0.160.16~0.250.25~0.40.4~0.630.63~11~1.6
1.6~2.52.5~44~65~86~109~1311~1714~2218~2622~3228~4034~5045~6355~7570~9080~100
Frame 32AF
-
23
MMS-63S MMS-63H MMS-100S MMS-100H- MMS-63HI - MMS-100HI
Standard High breaking Standard High breakingRotary Rotary Rotary Rotary
3 3 3 3Up to 690V Up to 690V Up to 690V Up to 690V50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz1,000V 1,000V 1,000V 1,000V
8kV 8kV 8kV 8kVCat. A Cat. A Cat. A Cat. AAC 3 AC 3 AC 3 AC 3
50,000 50,000 50,000 50,00025,000 25,000 25,000 25,000
25 25 25 25-20 ~ +60? -20 ~ +60? -20 ~ +60? -20 ~ +60?
13 ? Ie max. 13 ? Ie max. 13 ? Ie max. 13 ? Ie max.? ? ? ?? ? ? ?? ? ? ?? ? ? ?
55?125?112.3 55?125?112.3 70?165?138 70?165?1381,000 1,000 2,200 2,200
63AF 100AF
220V 220V240V 415V 460V 525V 690V 240V 415V 460V 525V 690V230V 400V 440V 500V 600V 230V 400V 440V 500V 600V
220V 220V240V 415V 460V 525V 690V 240V 415V 460V 525V 690V 230V 400V 440V 500V 600V 230V 400V 440V 500V 600V
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
100 100 100 100 15 12 10 8 4 3100 100 50 38 10 8 6 5 4 3100 100 25 19 10 8 6 5 4 350 38 25 19 10 8 6 5 4 350 38 25 19 10 8 6 5 4 350 38 25 19 10 8 6 5 4 350 38 25 19 10 8 6 5 4 350 38 25 19 10 8 6 5 4 350 38 25 19 10 8 6 5 4 3
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
100100 100 100 50 38 50 38 6 5100100 100 100 50 38 42 32 6 5100100 50 50 50 38 12 9 5 5100100 50 50 50 38 12 9 5 5100100 50 50 35 27 12 9 5 5100100 50 50 35 27 10 8 5 5100100 50 50 35 27 10 8 5 5100100 50 50 35 27 10 8 5 5100100 50 50 35 27 10 8 5 5
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
100 100 50 38 40 30 25 19 10 8100 100 50 38 40 30 25 19 10 8100 100 50 38 40 30 25 19 10 8100 100 50 38 40 30 15 11 10 8100 100 50 38 40 30 15 11 6 5100 100 50 38 40 30 12 9 6 5100 100 50 38 40 30 12 9 6 5100 100 50 38 40 30 8 6 5 4100 100 50 38 40 30 8 6 5 4100 100 50 38 40 30 8 6 5 4
Icu Ics Icu Ics Icu Ics Icu Ics Icu IcsIcu Ics Icu Ics Icu Ics Icu Ics Icu IcsIcu Ics Icu Ics Icu Ics Icu Ics Icu IcsIcu Ics Icu Ics Icu Ics Icu Ics Icu Ics
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
100100 100 100 50 38 35 27 12 9100100 100 50 50 38 35 27 12 9100100 100 50 50 38 35 27 12 9100100 100 50 50 38 25 19 12 9100100 100 50 50 38 20 15 12 9100100 100 50 50 38 15 11 10 8100100 100 50 50 38 15 11 8 6100100 75 50 50 38 12 9 6 6100100 75 50 50 38 12 9 6 6100100 75 50 50 38 12 9 6 6
-
24
Mold case circuit breakersSusol MCCB Series
TD100 TD160 TS100
?Applicable to MCCBs equipped with FTU, FMU, ATU ??? Available for 3pole circuit breakers ? 2 pole MCCB in 3pole frame size ???? Under development ?? 700A only available for TS800FTU ????? Not applicable to 1pole
1. The breakers with electronic trip units are available only at 3-pole version. (Only for AC supply)? The trip unit ATU is available from 125A
Frame size [AF]
Rated current, In ? [A]
No. of polesRated operational AC [V]voltage, Ue DC [V]Rated impulse withstand voltage, Uimp [kV]Rated insulation voltage, Ui [V]Rated ultimate short-circuit breaking capacity, Icu
AC 50/60Hz 220/240V [kA]380/415V [kA]440/460V [kA]480/500V [kA]660/690V [kA]
DC 250V [kA]500V(2poles in series) [kA]
Rated service breaking capacity, Ics [%Icu]Rated short-circuit making capacity Icm
AC 50/60Hz 220/240V [kA]380/415V [kA]440/460V [kA]480/500V [kA]660/690V [kA]
Category of utilizationIsolation behaviorTrip unit (release)
Thermal-Magnetic?fixed-thermal, fixed-magnetic FTU?adjustable-thermal, fixed-magnetic FMU?adjustable-thermal, adjustable-magnetic ATU?magnetic only MTU ???Electronic?LSI ETS ????LSI ETM ???
Option Earth-fault protection, IgZone selective interlocking, ZSI AmmeterCommunicationEarth-leakage protection module ????
Connection fixed front-connectionrear-connection
plug-in front-connectionrear-connection
Mechanical life [operations]Electrical life @ 415 V AC [operations]Basic dimensions, W?H?D 1-pole [mm](front connection) 3-pole [mm]
4-pole [mm]Weight 1-pole [kg](front connection) 3-pole [kg]
4-pole [kg]Reference standard
100 160 100
16, 20, 25, 32, 40, 1P: 16, 20, 25, 32, 40, 50,
50, 63, 80, 100 63, 80, 100, 125, 160 40, 50, 63, 80, 1002, 3P: 100, 125, 1602?, 3, 4 1, 2?, 3, 4 2?, 3, 4
690 240(1P), 690 690500 250(1P), 500 5008 8 8
750 750 750N H L N H L N H L
30(1P) 50(1P)85 100 200 85 100 200 100 120 20050 85 150 50 85 150 50 85 15050 70 130 50 70 130 50 70 13030 50 65 30 50 65 42 65 855 8 10 5 8 10 10 15 20
16(1P) 25(1P)42 65 100 42 65 100 50 85 100
42 65 100 42 65 100 50 85 100100% 100% 100% 100% 100% 100% 100% 100% 100%
105(1P) 105(1P)187 220 440 187 220 440 220 264 440
105 187 330 105 187 330 105 187 330105 154 286 105 154 286 105 154 28663 105 143 63 105 143 88 143 1878 14 17 8 14 17 17 30 40
A A A? ? ?
? ? ?? ?????? ?- - -
- - ?
- - ?- - -
- - -
- - -
- - -
- - -
- - -
? ? ?? ?????? ?? ?????? ?? ?????? ?
25000 25000 2500010000 10000 10000
- 35?140?86 -90?140?86 90?140?86 105?160?86120?140?86 120?140?86 140?160?86
- 0.57 -1.5 1.5 21.8 1.8 2.6
IEC60947-2 IEC60947-2 IEC60947-2
Note) 1. ? applicable or available2. ? available as a separate breaker
-
25
TS160 TS250 TS400 TS630 TS800
160 250 400 630 800
(100)?, 125, 160 125, 160, 200, 250 300, 400 500, 630 700??, 800
2?, 3, 4 2?, 3, 4 2?, 3, 4 2?, 3, 4 2?, 3, 4690 690 690 690 690500 500 500 500 5008 8 8 8 8
750 750 750 750 750N H L N H L N H L N H L N H L
100 120 200 100 120 200 100 120 200 100 120 200 100 120 200
50 85 150 50 85 150 65 85 150 65 85 150 65 100 15050 70 130 50 70 130 65 85 130 65 85 130 65 100 13042 65 85 42 65 85 42 65 85 42 65 85 42 85 10010 15 20 10 15 20 10 20 35 10 20 35 10 20 35
50 85 100 50 85 100 50 85 100 50 85 100 50 85 100
50 85 100 50 85 100 50 85 100 50 85 100 50 85 100100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
220 264 440 220 264 440 220 264 440 220 264 440 220 264 440
105 187 330 105 187 330 143 187 330 143 187 330 143 220 330105 154 286 105 154 286 143 187 286 143 187 286 143 220 28688 143 187 88 143 187 88 143 187 88 143 187 88 187 22017 30 40 17 30 40 17 40 74 17 40 74 17 40 74
A A A A A? ? ? ? ?
? ? ? ? ?? ? ? ? ?? ? ? ? ?? ? ? ? ?
? ? ? ? ?- - ? ? ?- - ? ? ?- - ? ? ?- - ? ? ?- - ? ? ?- - ? ? ?? ? ? ? ?? ? ? ? ?? ? ? ? ?? ? ? ? ?
25000 25000 20000 20000 1000010000 10000 6000 6000 3000
- - - - -
105?160?86 105?160?86 140?260?110 140?260?110 210?320?135140?160?86 140?160?86 186.5?260?110 186.5?260?110 280?320?135
- - - - -
2 2 5.4 5.4 15.12.6 2.6 7.2 7.2 19.6
IEC60947-2 IEC60947-2 IEC60947-2 IEC60947-2 IEC60947-2
Amb. Temp. -5C 0C 10C 20C 25C 30C 35C 40C 45C 50CCalibrated for 40C TD160 122.5% 120.0% 115.0% 110.0% 107.5% 105.0% 102.5% 100.0% 97.5% 95.0%
TS250 122.5% 120.0% 115.0% 110.0% 107.5% 105.0% 102.5% 100.0% 97.5% 95.0%TS630 110.0% 109.0% 107.0% 105.0% 104.0% 103.0% 101.5% 100.0% 98.5% 97.0%TS800 110.0% 109.0% 107.0% 105.0% 104.0% 103.0% 101.5% 100.0% 98.5% 97.0%
Calibrated for 50C TD160 122.0% 120.0% 116.0% 112.0% 110.0% 108.0% 106.0% 104.0% 102.0% 100.0%TS250 122.0% 120.0% 116.0% 112.0% 110.0% 108.0% 106.0% 104.0% 102.0% 100.0%TS630 122.2% 112.0% 110.0% 108.0% 107.0% 106.0% 104.5% 103.0% 101.5% 100.0%TS800 112.2% 112.0% 110.0% 108.0% 107.0% 106.0% 104.5% 103.0% 101.5% 100.0%
-
26
Molded case circuit breakersMetasol 30AF to 250AF Series
Note) 1. ? applicable or available2. ? available as a separate breaker
Frame Size(AF)
S-Type N-Type S-Type H-Type N-Type S-TypeABS32c ABN52c ABS52c ABH52c ABN62c ABS62cABS33c ABN53c ABS53c ABH53c ABN63c ABS63cABS34c ABN54c ABS54c ABH54c ABN64c ABS64c(3, 5, 10)
15, 20, 30, 40, 5015, 20, 30,
15, 20, 30, 40, 50, 6015, 20, 30 40, 50
690 690 690 690 690 690500 500 500 500 500 500750 750 750 750 750 750
8 8 8 8 8 8
2.5 2.5 5 10 2.5 57.5 7.5 10 35 7.5 10
14 (10) 14 18 50 14 1818 (14) 18 22 50 18 2230 (25) 30 35 100 30 35
5 5 10 30 5 105 5 10 30 5 10
100 100 100 100 100 100A A A A A A
fixed fixed fixed fixed fixed fixed
? ? ? ? ? ?
? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?
75?130?60 75?130?60 90?155?60 75?130?600.5 0.5 0.5 0.7 0.5 0.50.7 0.7 0.7 1 0.7 0.70.9 0.9 0.9 1.2 0.9 0.9
30 50 60
Rated short-circuit breaking capacity(Icu) kA (Sym), KSC8321, IEC 60947-2
TypeType and Pole 2 pole
3 pole4 pole
Rated current, In A
Rated operational AC(V)voltage, Ue DC(V)Rated insulation voltage, Ui VRated impulse withstand
kVvoltage, Uimp
AC 690V480/500V415/460V380V220/250V
DC 500V(3P)250V(2P)
Service breaking capacity(%Icu), IcsCategory of useEndurance Mechanical(Number of operations) ElectricalType of trip unitThermal-magnetic releaseHydraulic-magnetic releaseMagnetic release only without thermal tripEarth leakage protection for 3 pole AccessoriesElectrical auxiliaries Auxiliary switch
Alarm switchShunt tripUndervoltage trip
External accessories Direct rotary handleExtended rotary handleTerminal shieldInsulation barrierRear connection Pad handle lockPlug-in device
Dimensions (mm) W?H?D (3P)Weight(kg) 2 pole
3 pole4 pole
-
27
100 125 250
N-Type S-Type H-Type N-Type S-Type H-TypeABN102c ABS102c ABH102c ABN202c ABS202c ABH202cABN103c ABS103c ABH103c ABN203c ABS203c ABH203cABN104c ABS104c ABH104c ABN204c ABS204c ABH204c
15, 20, 30, 40,15, 20, 30, 40, 50, 60, 75, 100, 125 100, 125, 150, 175, 200, 225, 250
50, 60, 75, 100690 690 690 690 690 690500 500 500 500 500 500750 750 750 750 750 750
8 8 8 8 8 8
5 8 10 8 8 1010 25 30 18 26 3018 37 50 26 37 5022 42 50 30 42 5035 85 100 65 85 10010 20 30 10 20 3010 20 30 10 20 30100 100 100 100 100 100A A A A A A
fixed fixed fixed fixed fixed fixed
? ? ? ? ? ?
? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?? ? ? ? ? ?
75?130?60 90?155?60 105?165?600.5 0.7 0.7 1.1 1.1 1.10.7 1 1 1.2 1.2 1.20.9 1.2 1.2 1.6 1.6 1.6
Amb. Temp. -5C 0C 10C 20C 25C 30C 35C 40C 45C 50CCalibrated for 40C In=15 to 30 111.9% 111.3% 110.0% 108.0% 106.6% 104.9% 102.7% 100.0% 96.8% 93.3%
In=40 to 100 110.2% 109.8% 108.7% 107.0% 105.8% 104.3% 102.4% 100.0% 97.2% 94.0%In=100 to 225 114.3% 113.2% 110.6% 107.5% 105.8% 104.0% 102.0% 100.0% 97.9% 95.6%In=250 to 800 110.0% 109.0% 107.0% 105.0% 104.0% 103.0% 101.5% 100.0% 98.5% 97.0%
-
28
Molded case circuit breakersMetasol 400AF to 800AF Series
Note) 1. ? applicable or available2. ? available as a separate breaker
Frame Size(AF)
N-Type S-Type H-Type L-TypeABN402c ABS402c ABH402c ABL402cABN403c ABS403c ABH403c ABL403cABN404c ABS404c ABH404c ABL404c
250, 300, 350, 400690 690 690 690500 500 500 500750 750 750 750
8 8 8 8
5 8 10 1418 35 50 6537 50 65 8542 65 70 10050 75 85 12510 20 40 4010 20 40 40100 100 100 75A A A A
fixed fixed fixed fixed
? ? ? ?
? ? ? ?? ? ? ?? ? ? ?? ? ? ?? ? ? ?? ? ? ?? ? ? ?? ? ? ?? ? ? ?? ? ? ?? ? ? ?
140?257?1095.2 5.2 5.2 5.26.2 6.2 6.2 6.27.8 7.8 7.8 7.8
400
Rated short-circuit breaking capacity(Icu) kA (Sym), KSC8321, IEC 60947-2
TypeType and Pole 2 pole
3 pole4 pole
Rated current, In ARated operational AC(V)voltage, Ue DC(V)Rated insulation voltage, Ui VRated impulse withstand
kVvoltage, Uimp
AC 690V480/500V415/460V380V220/250V
DC 500V(3P)250V(2P)
Service breaking capacity(%Icu), IcsCategory of useEndurance Mechanical(Number of operations) ElectricalType of trip unitThermal-magnetic releaseHydraulic-magnetic releaseMagnetic release only without thermal tripEarth leakage protection for 3 pole AccessoriesElectrical auxiliaries Auxiliary switch
Alarm switchShunt tripUndervoltage trip
External accessories Direct rotary handleExtended rotary handleTerminal shieldInsulation barrierRear connection Mechanical interlockPlug-in device
Dimensions (mm) W?H?D (3P)Weight(kg) 2 pole
3 pole4 pole
-
29
800
N-Type S-Type L-TypeABN802c ABS802c ABL802cABN803c ABS803c ABL803cABN804c ABS804c ABL804c
500, 630, 700, 800690 690 690500 500 500750 750 750
8 8 8
8 10 1425 45 6537 65 8545 75 10050 85 12510 20 4010 20 40100 100 75A A A
fixed fixed fixed
? ? ?
? ? ?? ? ?? ? ?? ? ?? ? ?? ? ?? ? ?? ? ?? ? ?? ? ?? ? ?
210?280?10911 11 11
11.5 11.5 11.518.2 18.2 18.2
Amb. Temp. -5C 0C 10C 20C 25C 30C 35C 40C 45C 50CCalibrated for 40C In=15 to 30 111.9% 111.3% 110.0% 108.0% 106.6% 104.9% 102.7% 100.0% 96.8% 93.3%
In=40 to 100 110.2% 109.8% 108.7% 107.0% 105.8% 104.3% 102.4% 100.0% 97.2% 94.0%In=100 to 225 114.3% 113.2% 110.6% 107.5% 105.8% 104.0% 102.0% 100.0% 97.9% 95.6%In=250 to 800 110.0% 109.0% 107.0% 105.0% 104.0% 103.0% 101.5% 100.0% 98.5% 97.0%
-
30
Earth Leakage Circuit BreakersMetasol 30AF to 250AF Series
Note) 1. ? applicable or available2. ? available as a separate breaker
Frame Size(AF) 30 50 60
Rated short-circuit breaking capacity (Icu) kA (Sym), KSC8321, IEC 60947-2
TypeType and Pole 2-pole
3-pole4-pole
Protective function
Rated current, In A
Rated residual current, I?n mARated operational voltage,Ue AC(V)Rated impulse withstand kVvoltage, UimpResidual current off-time at I?n sec
AC 460V415V220/250V
Service breaking capacity(%Icu), IcsCategory of useEndurance Mechanical(Number of operations) ElectricalType of trip unitThermal-magnetic releaseHydraulic-magnetic releaseMagnetic release only without thermal tripEarth leakage protection for 3 pole AccessoriesElectrical auxiliaries Auxiliary switch
Alarm switchShunt tripUndervoltage trip
External accessories Insulation barrierTerminal cover (Long)Terminal cover (Short)Rotary handle (Direct)Rotary handle (Direct, Key lock)Rotary handle (Extended)Rear terminal (Bar)Rear terminal (Round)Plug-in kitPad handle lock
Dimensions (mm) W?H?D (3P)Weight(kg) 2 pole
3 pole4 pole
S-Type-
EBS33cEBS34c
Overload,Short-circuit and
Ground fault
15, 20, 30
30, 100/200/500220/460
6
?0.1 sec
141430100A
2500010000
fixed
?
??
??????
???
75?130?60-
0.70.9
N-Type S-TypeEBN52c -EBN53c EBS53c
- EBS54c
Overload, Short-circuit and Ground fault
15, 20, 30, 40, 50
30, 100/200/500220/460
6
?0.1 sec
14 1814 1830 35100 100 A A
25000 2500010000 10000
fixed fixed
? ?
? ?? ?
? ?? ?? ?? ?? ?? ?
? ?? ?? ?
75?130?600.5 -0.7 0.7- 0.9
H-Type-
EBH53cEBH54c
Overload,Short-circuit and
Ground fault15, 20, 30,
40, 5030, 100/200/500
220/460
6
?0.1 sec
5050100100A
2500010000
fixed
?
??
??????????
90?155?60-
11.2
N-Type S-Type- -
EBN63c EBS63c- EBS64c
Overload, Short-circuit and Ground fault
60
30,100/200/500220/460
6
?0.1 sec
14 1814 1830 35100 100A A
25000 2500010000 10000
fixed fixed
? ?
? ?? ?
? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?
75?130?60- -
0.7 0.7- 0.9