Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN...

67
Cast Stainless Steel Technology Developments Raymond Monroe SFSA

Transcript of Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN...

Page 1: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Cast Stainless Steel Technology Developments

Raymond Monroe SFSA

Page 2: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500
Page 3: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

CA 15 CB 7 CuCD4Cu

CF8

CN3MN

Page 4: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500
Page 5: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Calculation of Chromium Equivalent and Nickel Equivalent

CrE = %Cr + 2 × %Si + 1.5 × %Mo+ 5 × %V

NiE = %Ni + 0.5 × %Mn + 30 × %C+ 0.3 × %Cu

Page 6: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Ferrite from Chemistry

• Chemistry: C=0.07, Mn=0.56, Si=1.30, P=0.028, S=0.009, Cr=19.5, Ni=10.7, Mo=2.18 (Cb ~ 0.05 and N ~ 0.04)

• ASTM A800 predicts 10.5 volume percent ferrite with a range of 6.5 to 14.5 (chromium equivalent to nickel equivalent = 1.19)

Schoefer Diagram

0.8

0.9

1

1.1

1.2

1.3

1.4

1.5

1.6

1.7

1.8

1.9

2

2.1

2.2

0 10 20 30 40 50 60 70

Volume Percent Ferrite

Cr/N

i Com

posi

tion

Rat

io

77.2%)02.0N(26(%)Mn5.0(%)C30(%)Ni99.4(%)Nb(%)Mo4.1(%)Si5.1(%)Cr

NiCr

e

e

+−+++−+++

=

Page 7: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Means of Calculating Ferrite• Severn Gage: 11• Feritscope: 7• Magne-Gage: 2• Two different instruments:

5• Manual point count• ASTM A800• 1949 Schaeffler Diagram• WRC Diagram

Unit of measure:• FN: 8 (all 4 of the non-

foundry)• Volume percent: 7• Use both methods: 2

Page 8: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Identification of Phases by CompositionFERRITE

AUSTENITE

Page 9: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Stainless Steels - Strength

Grade Yield (ksi) UTS (ksi)

CF8 70 30

CF3MN 75 37

4A(2205) 90 60

6A(Zeron 100) 100 65

Page 10: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Stainless Steel - Corrosion

Grade Critical pitting temperature oC

CF8 5 (calculated)

CF3MN 29 (calculated)

4A(2205) 35 - 40

6A(Zeron100) 45 – 55

Page 11: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Pseudo Phase Diagram for 68 % Fe – Cr Ni

Page 12: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500
Page 13: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

CCT Diagram - CD3MN5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min

1 10 100 1000 10000 100000500

550

600

650

700

750

800

850

900

950

1000

1050

1100

Time (minutes)

CCT curves (non-equil. initial & final)

TTT curves(initial & final)

Tem

p. (C

elsi

us)

none

Cooling Rate=1oC/min,σ phase <<1%

Cooling Rate=0.5oC/minσ phase <1%

Cooling Rate=0.1oC/minσ phase =8.72% ±3.38

Cooling Rate=0.01oC/minσ phase =17.62% ±3.46

Page 14: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

CCT Diagram - CD3MWCuNV0.175mm/sec V0.150mm/sec V0.100mm/sec 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min

1 10 100 1000500

550

600

650

700

750

800

850

900

950

1000

1050

1100

Time (minutes)

CCT curves (non-equil. initial & final)

TTT curves(initial & final)

Tem

p. (C

elsi

us)

none

Cooling Rate=5oC/minσ phase =3.61% ±2.64

Cooling Rate=2oC/minσ phase =7.10% ±2.12

Cooling Rate=1oC/minσ phase =10.09% ±1.13

Cooling Rate=0.5oC/minσ phase =10.37% ±2.22

Cooling Rate=0.1oC/minσ phase =10.60% ±2.82

Bridgman furnaceV=0.1mm/sec,σ phase<1%

Page 15: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

PROBLEM - Corrosion of High Alloy (6 wt% Mo) Stainless Steel Castings

Wrought AL6XN As-SolidifiedAL6XNCN3MN

1150oC/4 hrs

0

2

4

6

8

10

0 10 20 30 40

Wt %

of e

lem

ent

Distance (µm)

Dendrite cores Mo

Current minimum required heat treatment – 1150 °C/ 1hr (ASTM Standards A743

and A351)

Cast alloys and welds not as corrosion resistant due to:

– microsegregation – presence of σ phase

OBJECTIVE: Develop heat treating schedules and welding procedures that restore the corrosion resistance of castings and welds to a level comparable to that of wrought counterpart alloys

Page 16: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Typical Homogenization Results

As Cast CK3MCuN

3

4

5

6

7

8

9

10

0 20 40 60 80 100 120 140 160 180Distance (microns)

Mol

ybde

num

Con

cent

ratio

n (w

t%)

MoDendrite Cores

1150 4 Hour CK3MCuN

3

4

5

6

7

8

9

10

0 50 100 150 200 250 300Distance (Microns)

Mol

ybde

num

Con

cent

ratio

n (w

%)

Mo

1205 4 Hour CK3MCuN

3

4

5

6

7

8

9

10

0 20 40 60 80 100 120 140 160 180

Distance (microns)

Mol

ybde

num

Con

cent

ratio

n (w

t% Mo

• 1205 °C/4 hours needed for complete homogenization

Page 17: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

5.4%

22.3%

18.0%

13.8%

18.3%

13.2%

5.0%

1.7%

0.0%

5.0%

10.0%

15.0%

20.0%

25.0%

AL6XN As CastCN3MN

1150 1 Hour 1150 2 Hour 1150 4 Hour 1205 1 Hour 1205 2 Hour 1205 4 Hour

Wei

ght L

oss

(%)

CN3MN Corrosion Results – ASTM G48A

AS

TM M

inim

um

Page 18: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

33.080 −= ελModel can be used as a predictive tool to determine effective heat treatment

times for CN3MN prepared with various cooling rates

Page 19: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Need to establish acceptable cooling rate from the heat treatingtemperature to avoid formation of brittle secondary phase

Collaboration with Scott Chumbley (Iowa State)

Results from C. Muller and Scott Chumbley, Iowa State University

Impa

ct T

ough

ness

(ft-l

bs)

Impact toughness

Grain boundary precipitates

Impact toughness decreases significantly with time at 870 oC, which could occur for large castings cooled slowly from the heat treating temperature

Need to establish critical cooling rates in order to avoid embrittlement.

Page 20: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Charpy Impact Toughness decreases significantly with an extremely slow cooling rate (0.01°C/sec)

Charpy Impact Toughness is unaffected by cooling rate above 1°C/sec

Toughness and Corrosion Performance

Corrosion Performance decreases at an extremely slow cooling rate (0.01°C/sec)

Corrosion Performance is unaffected by cooling rate above 1°C/sec

Slow cooling rate sample shows evidence of grain boundary attack

CK3MCuN CN3MN

CK3MCuN CN3MN

Page 21: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Corrosion of Welds in Super Austenitic Stainless Steel Castings

CN3MN 1205oC/4 hrs with Autogenous Weld

CN3MN As-Cast

CN3MN 1205oC/4 hrs

1 cm 1 cm

1 cmBase Metal Weld

Welding reintroduces the microsegregation profile

Percent Mass LossPercent Mass Loss

CN3MN As-Cast

CN3MN 1205°C/4hr

22% 2%

CN3MN 1205°C/4hr with Autogenous Weld

14%

Page 22: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Corrosion Resistance as a Function of Dilution(IN686 Filler Metal Welds on CN3MN)

1cm

1cm

Base Metal

1cm

Weld Metal

6.2 wt% Mo

11.0 wt% Mo

12.4 wt% Mo

7.9 wt% Mo

1cm1 cm

14.0 wt% Mo

ASTM G48a Temperature: 75° C Solution: FeCl3 (Ferric Chloride)

Corrosion performance increases with decreasing dilution levelCorrosion performance of weld can restored to level of cast material at dilution levels below ~ 50%

Page 23: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Corrosion Resistance as a Function of Dilution(IN72 Filler Metal Welds on CN3MN)

6.2 wt% Mo 20.6 wt% Cr

3.2 wt% Mo 31.5 wt% Cr

2.3 wt% Mo 34.9 wt% Cr

5.1 wt% Mo 24.4 wt% Cr

1cm

Weld Metal

Base Metal

1 cm1 cm

1 cm1 cm

1.3 wt% Mo 38.5 wt% Cr

ASTM G48a Temperature: 75° C Solution: FeCl3 (Ferric Chloride)

Corrosion performance increases with decreasing dilution levelIN72 Filler metal unable to avoid localized corrosion in weld

Page 24: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Corrosion Results: IN686 Filler Metal

Heat Treatments have a significant effect on corrosion performance

Post weld heat treatments (PWHT) will mitigate negative effects of dilution

Heat treatments should be done after welding, if possible (no need to control dilution)

Post Weld Heat Treatment at 1205°C/4hr produces the best corrosion resistance

Page 25: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Air-Set Pouring

Page 26: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Nondestructive Examination

• Surface– Visual– Magnetic particle examination (MT)– Liquid penetrant examination (PT)

• Volume– Radiographic examination (RT)– Ultrasonic examination (UT)

Page 27: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Examination• Visual

– ASTM A802– MSS SP55

• Magnetic Particle– ASTM E709– ASTM E125– MSS SP53

• Liquid Penetrant– ASTM E165 Method– ASTM E433 Acceptance– MSS SP93

Page 28: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Visual Examination

• Equipment required: surface comparator, pocket rule, straight edge, workmanship standards

• Enables detection of: surface flaws – cracks, porosity, slag inclusions, adhering sand, scale, etc.

• Advantages: low cost, can be applied while work is in process to permit correction of faults

• Limitations: applicable to surface defects only, provides no permanent record

• Remarks: should always be the primary method of inspection, no matter what other techniques are required

Page 29: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Inspection 1 Inspection 2O

pera

tor 1

Ope

rato

r 2

Casting 3

Page 30: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Inspection 1 Inspection 2O

pera

tor 1

Ope

rato

r 2

Foundry 3

Page 31: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Liquid Penetrant Examination

• Equipment required: commercial kits containing fluorescent or dye penetrants and developers, application equipment for the developer, a source of ultraviolet light – if fluorescent method is used

• Enables detection of: surface discontinuities not readily visible to the unaided eye

• Advantages: applicable to magnetic and nonmagnetic materials, easy to use, low cost

• Limitations: only surface discontinuities are detectable

Page 32: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Methodology• To determine the resolution of the process

– Only data from a minimum of three inspections per casting for each inspector was used.

– An indication must be detected at least 50% of the time or the data was not considered so results are a best case situation.

• The results were grouped by casting type, if multiple geometries were used, and also by inspector (to eliminate variation from inspector to inspector).

• Sample standard deviation was used as a measure of resolution.

Page 33: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Foundry 3• High alloy steel, visible liquid penetrant.• One casting shape, 10-15 lb cast weight.• Three Inspectors. • Twenty-four pieces per part type.• Three runs per inspector• Measured length and sketched location of

indications on part drawing.• A total of 216 inspections were made.

Page 34: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Casting Geometry 1AllInspector 3Inspector 1 Inspector 2

Standard Deviation95% confidence interval for mean0.0” to 0.04”

Standard Deviation Standard Deviation

Box-and-Whisker Plot

0.009 0.013 0.017 0.021 0.025

95% confidence interval for mean 0.0” to 0.2”

95% confidence interval for mean 0.0” to 0.02”

Standard Deviation

95% confidence interval for mean 0.01” to 0.5”

Box-and-Whisker Plot

0 0.1 0.2 0.3 0.4

Box-and-Whisker Plot

0 0.005 0.01 0.015 0.02 0.025

Box-and-Whisker Plot

0 0.1 0.2 0.3 0.4

Punch Line – The resolution for all inspectors is about 0.4”.

Page 35: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Radiographic Examination• Equipment required: commercial x-ray or gamma units made especially for inspecting welds, castings, and forgings with film and processing facilities

• Enables detection of: internal macroscopic flaws – cracks, porosity, blow holes, non-metallic inclusions, shrinkage, etc.

• Advantages: when the indications are recorded on film, gives a permanent record

• Limitations: cracks difficult to detect, requires safety precautions, requires skill in choosing angles of exposure, operating equipment, and interpreting indications

• Remarks: radiographic inspection is required by many codes and specifications, useful in qualification of processes, its use should be limited to those areas where other methods will not provide the assurance required because of cost

Page 36: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Results for Unanimous Agreement in X-Ray Ratings

• Unanimous agreement in shrinkage type: 37% (47/128)• 14 Level 0 (no type)• 20 CB• 7 CA• 6 CC

• Unanimous agreement in shrinkage level: 17% (22/128)• 14 Level 0• 1 Level 1• 1 Level 2• 1 Level 3• 5 Level 5

• Unanimous agreement in level and type: 12.5% (16/128)• 14 Level 0• 2 CB5

Page 37: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Casting Simulation– Each trial plate was simulated with recorded casting

conditions

– Niyama values (Ny)were measured

• minimum Ny

• area of Ny< 0.1 (K-s)1/2mm-1

top view cross-section

side view cross-section

TGNy&

=

G: temperature gradient (K/mm)T: cooling rate (K/s)

Page 38: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Casting Simulation– Combine trial and simulation results:

• Trial results: X-ray level vs. FL

• Simulation of trials: Nymin vs. FL

• Combine by eliminating FL → X-ray level vs. Nymin

-1

0

1

2

3

4

5

6

-0.1 0.1 0.3 0.5 0.7 0.9 1.1 1.3 1.5 1.7 1.9 2.1

AST

M S

hrin

kage

X-r

ay L

evel

Minimum Niyama Criterion Value, Nymin (K1/2s1/2mm-1)

W/T = 2, CF-8M (20 Plates)W/T = 5.5, CF-8M (50 Plates)W/T = 8, CF-8M (30 Plates)W/T = 8, HH (20 Plates)W/T = 8, HP (20 Plates)W/T = 12, CF-8M (25 Plates)

Level 5: 25 PlatesLevel 4: 6 PlatesLevel 3: 12 PlatesLevel 2: 15 PlatesLevel 1: 24 PlatesLevel 0: 83 Plates

TOTAL: 165 Plates

25

6

70

9

11

14

15

13

0

-1

0

1

2

3

4

5

6

0 0.1 0.2

X-r

ay L

evel

Nymin (K1/2s1/2mm-1)

0.074

0.005

0.022

0.024

Mean Minimum Niyama Values+/- One Standard Deviation

Page 39: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

0.0

0.5

1.0

1.5

2.0

2.5

0 1 2 3 4 5

Average X-ray Level Groupings

Ave

rage

One

-Sid

ed S

tude

nt-t

95%

Con

fiden

ce In

terv

al

39 x-rays

35 x-rays

27 x-rays

11 x-rays

8 x-rays

8 x-rays

Ave

rage

X-r

ay

Leve

l < 0

.5

0.5

< X

avg

< 1.

5

1.5

< X

avg

< 2.

5

2.5

< X

avg

< 3.

5

3.5

< X

avg

< 4.

5

Xav

g >

4.5

Data from all foundries Average one-sided student-t 95%confidence interval forall 128 x-rays = 1.42

Variation in the Ratings: Confidence intervals of x-ray level ratings grouped by average x-ray level

Page 40: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

• The root cause of leaks in fluid-containing castings can be shrinkage porosity that extends through a wall.

• Sometimes, porosity is so small that it cannot be detected using industrial radiography.

• No method available to assure quality.

Background

Page 41: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

• The Niyama criterion, a common output from a casting computer simulation, can be used to predict shrinkage porosity.

Background

TGNy &=

Page 42: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

• What is the critical Niyama below which shrinkage porosity forms? (especially for high-Ni alloys)o Micro-porosity, Nymicro (not visible on radiograph)o Macro-porosity, Nymacro (visible on radiograph)

Background

TGNy &=

log10(Ny)

Pore Volume (%)

0

micro-shrinkage

macro-shrinkage

NymicroNymacro

Pore

Vol

ume

(%)

Page 43: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Case Study #3: Valve B

outer diameterof flange = 5”

Casting defect. Leaks around gasket• CG8M steel valve

cast in a silica sandshell mold

• After machining, 22%leaked around gasketon flange face duringpressure testing

• No shrinkage visibleon x-rays

Page 44: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Case Study #3: Valve B

∼ 0.1 mm

• leaking castings weresectioned, andphotomicrographswere taken

• microporosity evidentin leaking area

Page 45: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Case Study #3: Valve Boriginal rigging revised rigging

paddingadded

chillsetup

changed

Page 46: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Case Study #3: Valve B

diameteras-cast

machineddiameter

outerdiameterof gasket

seat

Ny = 1.38Ny = 1.36

revised riggingflange face

Nymin = 1.4

Page 47: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Case Study #3: Valve B

• Microporosity caused leaks in original rigging withNymin = 0.5 - 0.7

• Nymin = 1.4 for revised rigging

• Valves cast since rigging revised:• none have leaked• none have had any shrinkage indications on x-ray

Page 48: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Leaker Case Study #1

• Leaker was a 20# investment cast M35-1 valve

• 8 valves were cast and shipped to the customer, and one leaked during the customer’s pressure testing

• Leaker was returned to the foundry, with leak area circled

• Metallographic analysis (John Griffin, UAB)

leak

Page 49: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Photographs of Defects in Leak Area

mid-plane18 mm below mid-plane

leak exit location

• Outer diameter (OD) of leak area:

mid-plane

18 mm belowmid-plane

1 mm

Page 50: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Photographs of Defects in Leak Area• Casting through-thickness toward inner diameter (ID)

of leak area:

Page 51: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Photographs of Defects in Leak Area• Polished through-thickness specimen toward ID of

leak area, showing shrinkage porosity:

Page 52: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Niyama Values in Entire Valve

Page 53: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Niyama Values in Region of Leak

mid-plane

mid-plane

ID

OD

Nymin = 0.69

Nymin = 0.58

Niyama values are in units of (°C-s)1/2/mm

Page 54: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Niyama Values in Region of Leak

OD

ID

photos and simulation results are from the valve

mid-plane

Page 55: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Case Study #1 Summary• Simulation suggests potential for leak in valve

– At valve mid-plane:Nymin = 0.58 (°C-s)1/2/mm at ID, Nymin = 0.69 at OD

• These low Niyama values (Nymin < 1) correspond well with shrinkage porosity observed in metallographic sections.

Page 56: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Additional Examination Areas

2

5

6

3

1

4

• After examining the leaking area, additional areas were selected for metallographic examination (all regions on valve mid-plane):

4

1

36 2

5

region of leak

Page 57: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Comparison: Region #1

Page 58: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Comparison: Region #2

A

B

B

A

A B

Page 59: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Comparison: Region #3

A

BA B

A

B

Page 60: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Comparison: Region #4

Page 61: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Comparison: Region #5

A

B

C

D

D

B

A

C

A

B

C

D

Page 62: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Comparison: Region #6

Page 63: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Additional Region Summary• In general, areas with Ny < 1 show a significant amount of

porosity (macroporosity)• In general, areas with 1 < Ny < 2 show a noticeable amount of

microporosity– Region #4 was a slight exception, with no substantial microporosity in

a region with 1.5 < Ny < 1.8

• In general, areas with Ny > 2 were free from shrinkage porosity

Page 64: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Leaker Case Study #2

leak (outside)

• 150# CN7M Valve Sand Casting:

leak (inside)

Page 65: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Leaker Case Study #2

cross-section of leaking area

OD

ID

shrinkage, possibly segregation

Page 66: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Case Study #2 Simulations• Original rigging:

• Nymin = 1.6 at OD, Nymin = 0.5 at ID• visible macro-porosity for Nymin < 1.0

OD

ID

Page 67: Cast Stainless Steel - 3-A Sanitary Standards, Inc. Meetings Present… · CCT Diagram - CD3MN 5oC/min 2oC/min 1oC/min 0.5oC/min 0.1oC/min 0.01oC/min 1 10 100 1000 10000 100000 500

Conclusions• In general, areas with Ny < 1 show a significant amount of

porosity (macroporosity)• In general, areas with 1 < Ny < 2 show a noticeable amount of

microporosity• In general, areas with Ny > 2 were free from shrinkage

porosity• It appears that the Niyama criterion can be used for quality

assurance, especially if shrinkage porosity is so small that it cannot be detected by radiography.

• Note for MAGMAsoft users: the valves had only minimal feeding indications (porosity %); the shrink seen in the valves was only predicted using Niyama criterion.