CAMERA CONTROL UNIT

CCU-590/590P

OPERATION MANUAL [English]

1st Edition (Revised 1)

Page 2: CAMERA CONTROL UNIT CCU-590/590P - Инженер …iservice.kiev.ua/docs/pdf/CCU_590_MO.pdfCAMERA CONTROL UNIT CCU-590/590P OPERATION MANUAL [English] 1st Edition (Revised 1) 2 To

2

To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.

To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.

THIS APPARATUS MUST BE EARTHED.

WARNING:Using this unit at a voltage other than 120 V may require the use of a different line cord or attachment plug, or both. To reduce the risk of fire or electric shock, refer servicing to qualified service personnel.

Attention-when the product is installed in Rack:

1.Prevention against overloading of branch circuitWhen this product is installed in a rack and is supplied power from an outlet on the rack, please make sure that the rack does not overload the supply circuit.

2.Providing protective earthWhen this product is installed in a rack and is supplied power from an outlet on the rack, please confirm that the outlet is provided with a suitable protective earth connection.

3.Internal air ambient temperature of the rackWhen this product is installed in a rack, please make sure that the internal air ambient temperature of the rack is within the specified limit of this product.

4.Prevention against achieving hazardous condition due to uneven mechanical loadingWhen this product is installed in a rack, please make sure that the rack does not achieve hazardous condition due to uneven mechanical loading.

5.Install the equipment while taking the operating temperature of the equipment into considerationFor the operating temperature of the equipment, refer to the specifications of the Operation Manual.

6.When performing the installation, keep the following space away from walls in order to obtain proper exhaust and radiation of heat.Right, Left : 4 cm (1.6 inches) or more

Rear : 10 cm (4 inches) or more

For the customers in the U.S.A. (for CCU-590)This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.

All interface cables used to connect peripherals must be shielded in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules.

For the State of California, USA onlyPerchlorate Material - special handling may apply, Seewww.dtsc.ca.gov/hazardouswaste/perchloratePerchlorate Material : Lithium battery contains perchlorate.

For the customers in Europe (for CCU-590P)This product with the CE marking complies with both the EMC Directive and the Low Voltage Directive issued by the Commission of the European Community. Compliance with these directives implies conformity to the following European standards: • EN60950-1 : Product Safety • EN55103-1 : Electromagnetic Interference (Emission) • EN55103-2 : Electromagnetic Susceptibility (Immunity) This product is intended for use in the following Electromagnetic Environments: E1 (residential), E2 (commercial and light industrial), E3 (urban outdoors), E4 (controlled EMC environment, ex. TV studio)

For the customers in Europe (for CCU-590P)The manufacturer of this product is Sony Corporation, 1-7-1 Konan, Minato-ku, Tokyo, Japan.The Authorized Representative for EMC and product safety is Sony Deutschland GmbH, Hedelfinger Strasse 61, 70327 Stuttgart, Germany. For any service or guarantee matters please refer to the addresses given in separate service or guarantee documents.

For kundene i NorgeDette utstyret kan kobles til et IT-strømfordelingssystem.

For the customers in Taiwan only

This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

WARNING

Page 3: CAMERA CONTROL UNIT CCU-590/590P - Инженер …iservice.kiev.ua/docs/pdf/CCU_590_MO.pdfCAMERA CONTROL UNIT CCU-590/590P OPERATION MANUAL [English] 1st Edition (Revised 1) 2 To

3Table of Contents

Table of Contents

Overview ............................................................................... 4Function and Location of Parts and Controls ................... 5

Front panel ................................................................................ 5Rear panel ................................................................................. 6

Internal Switches and Internal Boards ............................... 9Internal switches ........................................................................9Internal boards ...........................................................................9

Connecting the CCU-590/590P to the Video Camera ...... 10Notes on connections .............................................................. 10

Self-Diagnostics ................................................................. 11Settings of the camera..............................................................11Status display of the camera system ........................................11Self-diagnostics of the camera system.....................................11Settings of the network ............................................................12Self-diagnostics results of the CCU-590/590P internal

boards .............................................................................13Self-diagnostics results of the camera internal boards ............14ROM version indication ..........................................................15Exiting the Self-diagnostic mode.............................................15When an error occurs...............................................................15

Specifications ..................................................................... 15General.....................................................................................15Input signals.............................................................................15Output signals ..........................................................................15Camera input/output signals ....................................................16Supplied accessories ................................................................16Optional accessories ................................................................16

Page 4: CAMERA CONTROL UNIT CCU-590/590P - Инженер …iservice.kiev.ua/docs/pdf/CCU_590_MO.pdfCAMERA CONTROL UNIT CCU-590/590P OPERATION MANUAL [English] 1st Edition (Revised 1) 2 To

4

Overview

The CCU-590/590P Camera Control Unit provides a variety of remote control and adjustment functions for the processing of signals from a BVP-E10/E10P/E10WS/E10WSP/E30/E30P/E30WS/E30WSP CCD Color Video Camera, and can be used in Electronic Field Production (EFP) or studio work.

The CCU-590/590P has the following features:

Wide variety of system configurations• The optional CA-905K/F/T large-lens adaptor allows a

large lens to be fitted onto the portable video camera and used in conjunction with the BVF-77/77CE 7-inch B/W Viewfinder.

• 3 output lines (composite video or SDI can be selected as the output signal) are provided.

• When equipped with the optional RM-B750 Remote Control Unit, the RM-B750 can be used to control the video camera directly, without the use of a RCP-750/751/920/921 Remote Control Panel.

When the CCU-590/590P is connected to the CNU-700 Camera Network Unit and the RM-B750 is attached to the front panel of the CCU-590/590P, control on the camera system from the RM-B750 cannot be carried out.

• The CCU-590/590P supports communications between the video camera and the CCU-590/590P over either a triax cable or coaxial cable. (Power, however, is not supplied to the video camera in the case of coaxial cable.)

10-MHz, wideband triax transmission• Wideband triax transmission with Y signal at 10 MHz,

R-Y and B-Y signals at 6 MHz is used for inputting video signals from the video camera. The triax cable length can be extended from 50 to 700 m (with Fujikura φ8.5 mm cables), 75 to 1,050 m (with BELDEN 9232 φ13.2 mm cables), or 100 to 1,400 m (with Fujikura φ14.5 mm cables).

• The CCU-590/590P supports teleprompter signal transmission. Teleprompter signals can be transferred over distances of 50 to 500 m (with Fujikura φ8.5 mm cables), 75 to 750 m (with BELDEN 9232 φ13.2 mm cables), or 100 to 1,000 m (with Fujikura φ14.5 mm cables).

Rack mountableTwo CCU-590/590Ps can be mounted side by side in a standard 19-inch EIA rack when using an optional RMM-301 Rack Mount Adaptor.

Production of some of the peripherals and related devices described in this manual has been discontinued. For advice about choosing devices, please contact your Sony dealer or a Sony sales representative.

Note

Note

Overview

Page 5: CAMERA CONTROL UNIT CCU-590/590P - Инженер …iservice.kiev.ua/docs/pdf/CCU_590_MO.pdfCAMERA CONTROL UNIT CCU-590/590P OPERATION MANUAL [English] 1st Edition (Revised 1) 2 To

Function and Location of Parts and Controls

Front panel

a Camera number sheet/tally indicatorLights red when the red tally signal is input (e.g. when the video signal from the video camera connected to the CCU-590/590P goes on air). When the CALL button on the video camera, MSU-900/950, RCP-750/751/920/921 series remote control panel, or an optional RM-B750 is pressed, the indicator lights if it is not lit, and goes off if it is lit.The indicator lights green when the green tally signal is input (e.g. when the video signal from the camera connected to the CCU-590/590P goes off air).Attach the supplied number sheet here to indicate the camera number.

b POWER switch/CAM (camera) and MAIN indicators

The POWER switch turns on or off the power supply to the entire camera system, including the CCU-590/590P, the video camera, and the remote control unit connected to the REMOTE connector on the CCU-590/590P.The MAIN and CAM indicators light when the POWER switch is turned on.The CAM indicator goes off when the power is turned off by the CAM PW button on the remote control panel or the

master setup unit, or CAM POWER switch on the internal AT board.

If the fan in the CCU-590/590P stops, the MAIN indicator will flash to warn you of the abnormal condition. If this occurs, turn the POWER switch off immediately and contact Sony service personnel.

c CABLE ALARM indicatorsOPEN: Lights when no triax cable is connected to the

CAMERA connector on the rear panel of the CCU-590/590P, or when the load current is extremely low even when a camera cable is connected.

SHORT: Lights when there is a current overflow in the triax cable.

d INCOM audio input/output/setting section

INCOM (intercom) connector (XLR, 5-pin)Connects a headset.

INCOM level controlAdjusts the input level of the intercom.

"

1

CAM

ON PROD

PGM PGM

MIC –

OFF PRIV

OPEN

SHORT

MAIN

b POWER switch/CAM and MAIN indicators

aCamera number sheet/tally indicator

c CABLE ALARM indicators

d INCOM audio input/output/setting section

Note

Function and Location of Parts and Controls 5

Page 6: CAMERA CONTROL UNIT CCU-590/590P - Инженер …iservice.kiev.ua/docs/pdf/CCU_590_MO.pdfCAMERA CONTROL UNIT CCU-590/590P OPERATION MANUAL [English] 1st Edition (Revised 1) 2 To

6

MIC/PGM (program audio) switchON: Turns on the headset microphone.OFF: Turns off the headset microphone.PGM: Outputs the program audio when the one ear

headset is used. When this position is selected, the INCOM level control adjusts input level of the program audio. The level of the PGM1 and PGM2 can be adjusted by using the VR located on the panel side of the internal AU board.

INCOM (intercom) selectorSelects the pathway of intercom signals output/input through the INCOM/TALLY/PGM connector.PROD: Producer line.PRIV: Producer line and engineer line are cut off and

communication is possible only between the CCU-590/590P and the camera connected to the rear panel of the CCU-590/590P.

ENG: Engineer line. The settings regarding the output intercom signals can be performed on the internal AU board. For details, consult your Sony service personnel.

Rear panel

a CAMERA connector (triax connector)Connects to the CA-570/570P/590/590P/905K/F/T Camera Adaptor attached to the BVP-E10/E10P/E10WS/E10WSP/E30/E30P/E30WS/E30WSP Color Video Camera using a triax cable.

Do not use a defective triaxial cable.The inner sheath of a triaxial cable is used for power supply and the outer sheath for safety ground.

For your safety, do not use a triaxial cable whose inner and outer sheaths are short-circuited. Use of such a cable will cause electric shock.

b AUDIO OUTPUT connectors (XLR, 3-pin)Supply audio signals from the video camera.

a CAMERA connector

b AUDIO OUTPUT connectors

c INPUT connectors

d OUTPUT connectors

e REMOTE connector

f ETHERNET connector

g INTERCOM/TALLY/PGM connector

h MIC REMOTE connector

i WF MODE connector

j AC IN connector

Caution

Function and Location of Parts and Controls

Page 7: CAMERA CONTROL UNIT CCU-590/590P - Инженер …iservice.kiev.ua/docs/pdf/CCU_590_MO.pdfCAMERA CONTROL UNIT CCU-590/590P OPERATION MANUAL [English] 1st Edition (Revised 1) 2 To

c INPUT connectorsThe REFERENCE INPUT connectors, RET-1 connectors, and the RET-2/PROMPTER connectors are loop-through connectors.

A REFERENCE INPUT connectors (BNC type)The upper connector accepts reference signals (black burst signal) for external synchronization. The input signal is output from the lower connector. The reference input signal can be terminated at 75 ohms internally. To terminate the signal, input the reference signal to the upper connector.

B RET-1 (return video signal 1) connectors (BNC type)

The upper connector accepts return video signal. The input signal is output from the lower connector.

For details on the selection of RET-1, refer to Operation Manual that came with the camera or camera adaptor.

C RET-2 (return video signal 2)/PROMPTER connectors (BNC type)

The upper connector accepts return video signal or teleprompter signal. The input signal is output from the lower connector. The signal is split and output to the RET-2 and PROMPTER signal lines.

For details on the selection of RET-2, refer to Operation Manual that came with the camera or camera adaptor.

Use the switch on the internal board to output the prompter signal.

For details on the internal boards, consult your Sony service personnel.

D SDI (serial digital interface) RET-3/4 (return video signal 3/4) connectors (BNC type)

Accept SDI return video signal. (These connectors are not loop-through connectors.)

For details on the selection of RET-3 or RET-4, refer to Operation Manual that came with the camera or camera adaptor.

E COAX (coaxial) connector (BNC type)Accepts and supplies signal from/to the video camera using a coaxial cable. Power is not supplied to the camera or a camera adaptor through this connector.

To use this connector, it is required to change the setting of the internal board. For details, consult your Sony service personnel.

F SPARE connector (BNC type)Not used.

d OUTPUT connectors

A VBS (composite video signal)/SDI (serial digital interface)-1, VBS/SDI-2, VBS/SDI-3 connectors (BNC type)

Supply the signal from the video camera in composite or SDI format.Use the switch on the internal board to select the composite video signal or SDI signal.

For details on the internal boards, consult your Sony service personnel.

B Y/G, R-Y/R, B-Y/B (component video signal/RGB output) connectors (BNC type)

Supply the component signals or the R, G, and B signals for the chroma keyer from each connector.Use the switch on the internal board to select the signals to be output.

For details on the internal boards, consult your Sony service personnel.

C PIX (picture monitor output) connector (BNC type)Supplies a video signal or video and character signals together to a picture monitor.

A REFERENCE INPUT connectors

B RET-1 connectors

C RET-2/PROMPTER connectors

D SDI RET-3/RET-4 connectors

E COAX connector

F SPARE connector

A VBS/SDI-1, VBS/SDI-2, VBS/SDI-3 connectors

B Y/G, R-Y/R, B-Y/B connectors

C PIX connector

D SYNC connector

E WF connector

Function and Location of Parts and Controls 7

Page 8: CAMERA CONTROL UNIT CCU-590/590P - Инженер …iservice.kiev.ua/docs/pdf/CCU_590_MO.pdfCAMERA CONTROL UNIT CCU-590/590P OPERATION MANUAL [English] 1st Edition (Revised 1) 2 To

8

Use the WF/PIX Select menu (in MSU-950, RCP-750/751, or RM-B750) or the PICTURE MONITOR button (on MSU-900) to select the signal output from the PIX connector. When the output signal is changed on the RCP-750/751 or the RM-B750, the waveform output on the waveform monitor also changes.

D SYNC connectorConnect to the synchronous signal input connector on a waveform monitor or picture monitor.

E WF (waveform monitor output) connector (BNC type)

Supplies a video signal to a waveform monitor.Use the WF/PIX Select menu (in MSU-950, RCP-750/751, or RM-B750) or the WAVEFORM MONITOR button (on MSU-900) to select the signal output from the WF connector. When the output signal is changed on the RCP-750/751 or the RM-B750, the picture on the picture monitor also changes.

e REMOTE (remote control) connector (8-pin)Connects to the MSU-900/950 Master Setup Unit, RCP-750/751/920/921 Series Remote Control Panel or RM-B750 Remote Control Unit with an optional CCA-5-xx connecting cable to transmit/receive control signals.

f ETHERNET connectorThrough this connector, the Ethernet system can be built with the devices conforming to 700 Protocol Over TCP/IP, such as the MSU-900/950 or RCP-920/9211), etc. In order to build the Ethernet system, the internal switch setting and the network-related settings must be made.

For details, consult your Sony service personnel.

1)Power must be supplied to the RCP-920/921 through the Ethernet connection.

For safety, do not connect the connector for peripheral device wiring that might have excessive voltage to this port. Follow the instructions for this port.

g INTERCOM/TALLY/PGM (program audio) connector (D-sub, 25-pin)

Inputs/outputs intercom, tally, or program audio signals. Connects to an intercom, tally, or program audio connector of an intercom system.

h MIC REMOTE (microphone remote control) connector (D-sub, 15-pin)

Connects to an external control unit such as an audio mixer. With the connected unit, you can set the microphone input level of the video camera to –60, –50, – 40, –30, or –20 dB.

i WF MODE (waveform monitor mode) connector (4-pin)

Connects to the corresponding connector on a waveform monitor to allow the sequential monitoring of signals.

j AC IN (AC power input) connectorConnects to an AC power source using the supplied AC power cord. Secure the power cord to the CCU-590/590P using the supplied plug holder.

CAUTION

Function and Location of Parts and Controls

Page 9: CAMERA CONTROL UNIT CCU-590/590P - Инженер …iservice.kiev.ua/docs/pdf/CCU_590_MO.pdfCAMERA CONTROL UNIT CCU-590/590P OPERATION MANUAL [English] 1st Edition (Revised 1) 2 To

Internal Switches and Internal Boards

To reduce the risk of electric shock, fire or injury, do not open the cabinet. To adjust the internal settings, refer to qualified service personnel.

Internal switches

The following switches are located inside the unit, behind the front panel.

a Headset microphone switch 1 (S5)Set the switch according to the type of microphone of the headset connected to the INCOM connector on the front panel of this unit.CARBON: Carbon microphone (power supply, 20 dB

gain)ECM: Electret condenser microphone (power supply, 40

dB gain)DYNAMIC: Dynamic microphone (no power supply, 60

dB gain) (factory-setting)

b Headset microphone switch 2 (S6)When the headset microphone switch 1 (S5) is set to DYNAMIC, set this switch according to the type of output of the headset microphone.GND: Unbalanced type (factory-setting)OPEN: Balanced type

c Internal main power switchWhen an abnormality has occurred and power cannot be cut off with the POWER switch on the front panel, you may turn off the unit using the internal main power switch. When the switch is set to off, pressing the POWER switch on the front panel does not turn on the unit.

Internal boards

The internal boards are located inside the unit, behind the front panel.

For details on the internal boards, consult your Sony service personnel.

Note

ON

c Internal main power switch

bHeadset microphone switch 2 (S6)

aHeadset microphone switch 1 (S5)

AT EN IV AU DMTR

ON

Internal boards

Internal Switches and Internal Boards 9

Page 10: CAMERA CONTROL UNIT CCU-590/590P - Инженер …iservice.kiev.ua/docs/pdf/CCU_590_MO.pdfCAMERA CONTROL UNIT CCU-590/590P OPERATION MANUAL [English] 1st Edition (Revised 1) 2 To

10

Connecting the CCU-590/590P to the Video Camera

When connecting a CCU-590/590P to a BVP-E10/E10P/E10WS/E10WSP/E30/E30P/E30WS/E30WSP Color Video Camera, you must first attach the CA-570/570P/590/590P Camera Adaptor to the video camera.

A large lens and the BVF-77/77CE 7-inch Viewfinder are connected to the CCU-590/590P through the CA-905K/F/T series large-lens adaptor and the BKP-9057 Viewfinder Saddle, as shown in the illustration below.

Notes on connections

Triax cableThe triax cable should never be connected to or disconnected from the CCU-590/590P when the power is turned on. Always turn the unit off first.

Video cameraSome switches or controls on the video camera may not work when the camera is connected to the CCU-590/590P.

For details, refer to Operation Manuals of the video camera and the camera adaptor.

• The maximum power output from the CAMERA connector of the CCU-590/590P is 110 watts (including a cable loss of 10 watts). Do not connect any equipment which consumes more than 110 watts of power.

• The BVF-7700/7700P Color Viewfinder cannot be used because of the power output rating mentioned above.

Notes

CA-570/570P/590/590P

BVP-E10/E10P/E10WS/E10WSP/E30/E30P/E30WS/E30WSP

Triax cable

When a large lens is used

BVF-77/77CECA-570/570P/590/590P

BVP-E10/E10P/E10WS/E10WSP/E30/E30P/E30WS/E30WSP

BKP-9057

CA-905K/F/T

CCU-590/590P

To an AC power source

Connecting the CCU-590/590P to the Video Camera

Page 11: CAMERA CONTROL UNIT CCU-590/590P - Инженер …iservice.kiev.ua/docs/pdf/CCU_590_MO.pdfCAMERA CONTROL UNIT CCU-590/590P OPERATION MANUAL [English] 1st Edition (Revised 1) 2 To

Self-Diagnostics

The CCU-590/590P is equipped with the self-diagnostic function and you can display the self-diagnostics results of the system and the internal boards of the CCU-590/590P on the following monitors.• A picture monitor connected to the PIX connector• An SDI monitor connected to the VBS/SDI-3

connector1)

• The LCD/touch panel on the RM-B750 Control Panel2)

1)To select the SDI signal, switch setting on the internal board is necessary.For details on the setting, consult your Sony service personnel.

2)Press to light the MONITOR button on the RM-B750 to view the self-diagnostic results on the LCD/touch panel.

In all cases above, be sure to press to light the CHARACTER button on the RCP-750/751/920/921 Remote Control Panel.

To display the self-diagnostics pagesWhile the CHARACTER button on the remote control panel is turned off, press to light the button. The “Settings of the camera” page appears.

To display the next page of the self-diagnostics pagesPress the CHARACTER button on the remote control panel or the RM-B750.Each press of the button advances the page.When you press the CHARACTER button while the “ROM version indication” page appears, a screen with no characters (character OFF screen) appears.When you keep pressing the CHARACTER button, pages are automatically turned to the character OFF screen.

In this manual, self-diagnostics pages are shown in order of appearance.

The following illustrations of the self-diagnostics pages may differ from the actual indications depending on the settings and connections.

Settings of the camera

At the top of the screen, the following items are displayed from left to right: MASTER GAIN, CROP, EVS, SHUTTER, and SHUTTER ON/OFF.At the bottom of the screen, the following items are displayed from left to right: ND FILTER, IRIS, EXTENDER, and CC FILTER.

For the meanings of each item, refer to Operation Manuals of the video camera.

Status display of the camera system

BVP (the first column): Model name and format of the connected camera

CCU (the second column): Model name and format of the connected camera control unit

GenLock: The status of the external reference signalPrompter: Transmission direction of the teleprompter

signalD-sub15pin: Microphone input level setting performed

through the MIC REMOTE connectorReturn-1 to 4: The settings of the RET-1, RET-2/

PROMPTER, SDI RET-3/RET-4 connectors

Self-diagnostics of the camera system

The results of a self-diagnosis of the camera system are displayed in 3 pages.

Note

Self-Diagnostics 11

Page 12: CAMERA CONTROL UNIT CCU-590/590P - Инженер …iservice.kiev.ua/docs/pdf/CCU_590_MO.pdfCAMERA CONTROL UNIT CCU-590/590P OPERATION MANUAL [English] 1st Edition (Revised 1) 2 To

12

Page 1

TRIAX Type: Type of Triaxial circuitTRIAX Cable: Triax cable connection status (connected/

disconnected)TRIAX Comp.: Cable compensation of a triax cable

(automatic/manual)TRIAX Step: Compensation step of the triax cable (step

indication in the circuit) (The cable length may not be displayed correctly.)

Fan Power: Fan status in the CCU power block Timer: Power up time to devices connectedCCU Power: Status of the CCU power supply SerialNo: Serial number of the CCU

Page 2

CAMERA Cable: Camera cable connection status (connected/short-circuited)

CAMERA Data: Camera data transmission statusCAMERA Power: Power supply status of the cameraCAMERA Tone: Camera ID tone status RCP/CNU Cable: Connection status of the REMOTE

connector (connected/short-circuited)RCP/CNU Data: Data transmission status of the

REMOTE connectorRCP/CNU Power: Power supply status of the REMOTE

connector

The following items are displayed only when the F panel is connected.F-PANEL Cable: F-panel cable connection status

(connected/short-circuited)F-PANEL data: F-panel data transmission statusF-PANEL Power: Power supply status of the F-panel

Page 3

Intercom CCU: CCU intercom selectionIntercom CAMERA CH1: Status of intercom 1 of the

camera (producer line/engineer line)Intercom CAMERA CH2: Status of intercom 2 of the

camera (producer line/engineer line)CHU MIC Gain: Gain and control status of the

microphone circuit

Settings of the network

The following pages appear only when the CCU-590/590P is set so that it connects to the system through the Ethernet.In order for the CCU-590/590P to establish connection via Ethernet, internal settings must be made.

For details on the internal settings, consult your Sony service personnel.

The network settings are displayed in 3 pages.

Page 1

MacAddress: Mac address of the CCU-590/590PAuto Negotiation: Auto-negotiation settingAuto Mdix: Auto-MDIX settingConnect Speed: Connection speed settingDuplex Mode: Duplex mode settingMDI/MDIX Select: MDI/MDIX settingLink Status: Ethernet connection status

Self-Diagnostics

Page 13: CAMERA CONTROL UNIT CCU-590/590P - Инженер …iservice.kiev.ua/docs/pdf/CCU_590_MO.pdfCAMERA CONTROL UNIT CCU-590/590P OPERATION MANUAL [English] 1st Edition (Revised 1) 2 To

Page 2

NS Mode: Setting for the ETHERNET connection modeLEGACY: Connection mode for the REMOTE connector (factory-setting)BRIDGE: ETHERNET connection modeMCS: ETHERNET connection mode

MCS Mode: Setting of master or client for the Ethernet connection of the multi-camera systemCLIENT: Client mode (This unit is placed under control of the master device.)

CCU No.: CCU number settingMaster IP Address: IP address of the master device

Page 3

IP Addr: IP addressNetMask: Net maskDef GW: Default gateway

Self-diagnostics results of the CCU-590/590P internal boards

For details on the internal boards, refer to the System Manual.

DM board

CAM Video: Status of the Y, R-Y, and B-Y signals of the triax signal

Skin Gate: Reception status of the Skin gate signal from the camera

TRIAX Comp.: Cable compensation of a triax cable TRIAX Step: Compensation step of the triax cable (step

indication in the circuit) (The cable length may not be displayed correctly.)

Power: DM board power supply status

TR board

Prompter: Setting status of the prompter lineTone: Tone signal statusIncom: Demodulating status of the intercom lineCHU Data: Data reception status from the cameraPower: TR board power supply statusBoardID: ID number of the TR board

AT board

Reference: Operation mode of the phase adjustment

Self-Diagnostics 13

Page 14: CAMERA CONTROL UNIT CCU-590/590P - Инженер …iservice.kiev.ua/docs/pdf/CCU_590_MO.pdfCAMERA CONTROL UNIT CCU-590/590P OPERATION MANUAL [English] 1st Edition (Revised 1) 2 To

14

Gen Lock: Locking statusCCU Power: CCU power supply type (AC/DC) and power

supply statusBATT Volt: Voltage of the coin battery supplied with the

AT boardPLL Volt: Status of the PLL circuit of the AT boardCCU Mode: Operation mode of the CCUPLD: Status of the PLD mounted on the AT board and

program version of the PLDBoard ID: ID number of the AT board

AU board

MIC: Audio embedding for the main SDI video signal.FRONT-INCOM: Settings of the front intercomINCOM: Channel setting for the intercom made on the

video cameraPGM: Program audio settingAudioPLL: PLL status of the audio signalPower: AU board power supply statusCN: CN board power supply statusPLD: Status of the PLD mounted on the AU board and

program version of the PLDBoard ID: ID number of the AU board

IV board

RETURN: Input settings for the return channels 1 to 4MIX-Y: Setting for camera signal to be mixed with the

return signalPower: IV board power supply statusDIF: Power status of the DIF board connected to the rear

of the IV boardPLD: Status of the PLD mounted on the IV board and

program version of the PLD

BoardID: ID number of the IV board

EN board

Component: Setting status of the component output signal from the OUTPUT connector and status of the sync signal added to the component Y/G output signal from the OUTPUT connector

Composite: Setting status of the composite output signal from the OUTPUT connector

Power: EN board power supply statusVDA: Power supply status of the VDA board on the rearSC-REF: Lock status to the subcarrier of the external

reference signalPLD: Status of the PLD mounted on the EN board and

program version of the PLDBoardID: ID number of the EN board

Self-diagnostics results of the camera internal boards

Self-Diagnostics

Page 15: CAMERA CONTROL UNIT CCU-590/590P - Инженер …iservice.kiev.ua/docs/pdf/CCU_590_MO.pdfCAMERA CONTROL UNIT CCU-590/590P OPERATION MANUAL [English] 1st Edition (Revised 1) 2 To

ROM version indication

Exiting the Self-diagnostic mode

Press the CHARACTER button on the RCP-750/751/920/921 remote control panel or the RM-B750 repeatedly to display the ROM version indication page, then press the CHARACTER button again.

When an error occurs

The error message is displayed on the monitor. In such a case, the self-diagnostics page corresponding to the board where the error has occurred appears by pressing the CHARACTER button.

When you keep pressing the CHARACTER button, pages are automatically turned to a screen with no characters (character OFF screen).

Specifications

General

Power consumption100 - 240 V AC, 50/60 Hz, maximum

1.8 APeak inrush current

(1) Power ON, current probe method: 50 A (240 V)

(2) Hot switching inrush current, measured in accordance with European standard EN55103-1: 10 A (230 V)

Cable length1) 50 to 700 m (Fujikura φ8.5 mm)75 to 1,050 m (BELDEN 9232

φ13.2 mm)100 to 1,400 m (Fujikura φ14.5 mm)

Operating temperature–10 °C to +40 °C (14 °F to 104 °F)

Dimensions 200 × 124 × 365 mm (8 × 5 × 143/8 in.) (w / h / d) not including projecting parts

Mass Approx. 5.5 kg (12 lb 2 oz)

1) Teleprompter signals are only compatible with the following cable lengths. • 50 to 500 m (Fujikura φ8.5 mm) • 75 to 750 m (BELDEN 9232 φ13.2 mm)• 100 to 1,000 m (Fujikura φ14.5 mm)

Input signals

REFERENCE BNC type (loopthrough)VBS/BS, 1.0 Vp-p, 75 ohms

RET 1/22) BNC type (1 each, loopthrough)VBS, 1.0 Vp-p, 75 ohms

PROMPTER2) BNC type (loopthrough)1.0 Vp-p, 75 ohms

SDI RET 3/43) BNC type (1 each) VBS, 1.0 Vp-p, 75 ohms (terminated

internally)SDI format, 270 Mbps, SMPTE 259M

2) The same signal is input to the RET-2 connectors and the PROMPTER connector.

3) The signal selection (SDI or VBS) input to the SDI-RET 3/4 connectors is switchable.

Output signals

VBS/SDI 1/2/34) BNC type (1 each)VBS, 1.0 Vp-p, 75 ohmsSDI format, 270 Mbps, SMPTE 259M

Specifications 15

Page 16: CAMERA CONTROL UNIT CCU-590/590P - Инженер …iservice.kiev.ua/docs/pdf/CCU_590_MO.pdfCAMERA CONTROL UNIT CCU-590/590P OPERATION MANUAL [English] 1st Edition (Revised 1) 2 To

16

Y/R-Y/B-Y video5)

BNC type (1 each)Y: 1.0 Vp-p, 75 ohmsR-Y/B-Y: U.S.A. and Canada: 700 mVp-p, 75

ohmsEurope: 525 mVp-p, 75 ohms

R/G/B video5) BNC type (1 each)700 mVp-p, 75 ohms

PIX BNC type (1)1.0 Vp-p, 75 ohms

WF BNC type (1)NTSC: 714 mVp-p, 75 ohmsPAL: 700 mVp-p, 75 ohmsEncoded output: 1.0 Vp-p, 75 ohms

WF MODE 4-pin (1)AUDIO OUTPUT

XLR, 3-pin0 dBu/–20 dBu, balanced, 2 channels

SYNC BNC type (1)0.3 Vp-p, 75 ohms

4) The signal selection (VBS or SDI) output from the VBS/SDI 1/2/3 connectors is switchable.

5) R/G/B and Y/R-Y/B-Y are switchable.

Camera input/output signals

CAMERA Triax (Kings type for the U.S.A. and Canada, Fischer type for Europe)

COAX BNC type (1), 75 ohmsREMOTE 8-pin, multiconnectorETHERNET IEEE 802.3 10BASE-T, IEEE 802.3u

100BASE-TXINTERCOM/TALLY/PGM

D-sub, 25-pin (1)4W/RTSTALLY: 24 V DC, TTL level or contact

selectableMIC REMOTE D-sub, 15-pin (1)INCOM (on the front panel)

XLR, 5-pin (1)

Supplied accessories

AC power cord (1)AC power plug holder (1)4-pin connector (1)Number plate (1 set)Operation Manual (1)CD-ROM (1)

Optional accessories

Extension board (service parts)Remote Control Unit RM-B750Rack Mount Adaptor RMM-301

Design and specifications are subject to change without notice.

NoteAlways verify that the unit is operating properly before use. SONY WILL NOT BE LIABLE FOR DAMAGES OF ANY KIND INCLUDING, BUT NOT LIMITED TO, COMPENSATION OR REIMBURSEMENT ON ACCOUNT OF THE LOSS OF PRESENT OR PROSPECTIVE PROFITS DUE TO FAILURE OF THIS UNIT, EITHER DURING THE WARRANTY PERIOD OR AFTER EXPIRATION OF THE WARRANTY, OR FOR ANY OTHER REASON WHATSOEVER.

Specifications

Page 17: CAMERA CONTROL UNIT CCU-590/590P - Инженер …iservice.kiev.ua/docs/pdf/CCU_590_MO.pdfCAMERA CONTROL UNIT CCU-590/590P OPERATION MANUAL [English] 1st Edition (Revised 1) 2 To

The material contained in this manual consists of information that is the property of Sony Corporation and is intended solely for use by the purchasers of the equipment described in this manual.Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.

TrademarkEthernet is a registered trademark of Xerox Corporation.

Page 18: CAMERA CONTROL UNIT CCU-590/590P - Инженер …iservice.kiev.ua/docs/pdf/CCU_590_MO.pdfCAMERA CONTROL UNIT CCU-590/590P OPERATION MANUAL [English] 1st Edition (Revised 1) 2 To

CCU-590/590P

(UC/CE)

3-869-638-02 (1) © 2007

Sony Corporation