Cable A Cable C Cable B Dot RGB RGBW · RGB: 40 RGB: 28 RGBW: 36 RGBW: 26 X-lock Lead Cable...

1
TITLE: SYSTEM WIRING DIAGRAM - e:net connection DATE : 25 MAR 2020 DWG. BY : Please check for the latest updates and changes on the TRAXON website. ©2020 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. WWW.TRAXONTECHNOLOGIES.COM PRODUCTS: ALLEGRO DOT M/L RGBW SCALE : NOT TO SCALE PAGE : 1 OF 1 VER : 0.1 Installation engineer should use appropriate plugs for outdoor connection. Maximum number of Pixel Distributors in the daisy chain depends on available DMX and e:pix channels from 1st pixel distributor. Allegro Dot Pixel Distributor End cap Ethernet Switch SYMPL Core S Mains AC ~ DMX/RDM: 60 units max. e: pix: 15 units max. Max. number of Pixel Distributors in the daisy chain for standard model from ordering list. (Please refer the table below): 1PXL dots, RGBW: 4 channels per dot RGB: 3 channels per dot Last dot of string Indoor Outdoor Cable C Cable B Cable A RJ45 Male Connector Housing IP67 To other distributor chain To construct a longer data cable, use outdoor data cable with RJ45 housing. Outdoor cable specification: CAT-5e UTP/FTP PVC jacket; UV resistant Outer diameter 6mm/0.24” Filled type (The warranty will void if in use cable is not follow the specification of outdoor cable) Smart Junction LED Engine 100W 30V Outdoor e:net connection DMX/e:pix connection Dot pitch: 150mm minimum, 4000mm maximum The maximum number of Pixel (standard model with dot pitch 150mm) Dot M Dot L RGB: 40 RGB: 28 RGBW: 36 RGBW: 26 X-lock Lead Cable (5m/10m) Cable A Cable B TX Connect Data Bridge Indoor/Outdoor Cable (5m) Maximum: 50m TX Connect Data Outdoor Cable 0.6m/2ft or 3m/10ft available Cable C Dot RGB RGBW M 4 3 L 7 5 M 15 14 L 15 15 DMX e: pix WD0104US

Transcript of Cable A Cable C Cable B Dot RGB RGBW · RGB: 40 RGB: 28 RGBW: 36 RGBW: 26 X-lock Lead Cable...

Page 1: Cable A Cable C Cable B Dot RGB RGBW · RGB: 40 RGB: 28 RGBW: 36 RGBW: 26 X-lock Lead Cable (5m/10m) Cable A Cable B TX Connect Data Bridge Indoor/Outdoor Cable (5m) Maximum: 50m

TITLE:

SYSTEM WIRING DIAGRAM - e:net connectionDATE : 25 MAR 20 20

DWG. BY :

Please check for the latest updates and changes on the TRAXON website.©2020 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED.WWW.TRAXONTECHNOLOGIES.COM

PRODUCTS:

ALLEGRO DOT M/L RGBWSCALE : NOT TO SCALE

PAGE : 1 OF 1 VER : 0.1

Installation engineer should useappropriate plugs for outdoor connection.

Maximum number of Pixel Distributors in the daisy chain depends on available DMX and e:pix channels from 1st pixel distributor.

Allegro Dot Pixel Distributor

End cap

Ethernet Switch

SYMPL Core S

Mains AC ~

DMX/RDM: 60 units max.e: pix: 15 units max.

Max. number of Pixel Distributors in the daisy chain for standard model from ordering list.(Please refer the table below):

1PXL dots,RGBW: 4 channels per dot RGB: 3 channels per dot

Last dot of string

Indoor Outdoor

Cable C

Cable B

Cable A

RJ45 Male Connector Housing IP67

To other distributor chain

To construct a longer data cable,use outdoor data cable with RJ45housing.

Outdoor cable specification:CAT-5e UTP/FTPPVC jacket; UV resistantOuter diameter 6mm/0.24”Filled type(The warranty will void if in use cable is not follow the specification of outdoor cable)

Smart Junction

LED Engine 100W 30V Outdoor

e:net connection

DMX/e:pix connection

Dot pitch: 150mm minimum, 4000mm maximum

The maximum number of Pixel(standard model with dot pitch 150mm)Dot M Dot L RGB: 40 RGB: 28RGBW: 36 RGBW: 26

X-lock Lead Cable (5m/10m)

Cable A

Cable B

TX Connect Data Bridge Indoor/Outdoor Cable (5m)Maximum: 50m

TX Connect Data Outdoor Cable0.6m/2ft or 3m/10ft available

Cable C

Dot RGB RGBW

M 4 3

L 7 5

M 15 14

L 15 15

DMX

e: pix

WD0104US