R+R-T+T- G
1
From PLC
Code Addr0123456789101112131415
0123456789ABCDEF
ID-----------N10N11N1N43-
PT3014-C51F4-SK
B2
B4
21
12 14
K25
-N10
Control Techniques
PT3014-C51F4-SK User Manual
Code SW Setting
PwrRxTxTxRx
DB9 Female Front View
DB9 Male Rear view
8 << 1 3 = 0V4 = +24V56 = TE-7 = D-8 = JR2
2 = D+1 = JR1
B7For Motor Termistor
Trip resistance: 3k, Reset resistance: 1k8
T1 (0V)The drive will not trip if the thermistor goes short circuit
Commander-SK
No. Function Setting
08 Motor rated voltage Check Motor Nameplate
0102030405
07
0910111734
Minimum set speedMaximum set speedAcceleration rateDeceleration rateDriver configuration
Motor rated speed
Motor power factorParameter accessStart/Stop logic selectEnable negative preset speedsTerminal B7 mode select
0.0Check Motor Nameplate
5.010.0Pr.
Check Motor Nameplate
Check Motor NameplateL33Onth
39 Motor rated frequency Check Motor Nameplate
Parameter setting forControl Techniques Commander-SK
06 Motor rated current Check Motor Nameplate
40 Number of motor poles Check Motor Nameplate42 Low frequency voltage boost 5.143 Serial communication baud rate 2.444 Serial comms address 1
H 3~ Typ FDRU 80A/ 8 0NR.5166389 678819 B14Y 80// 400V2,5 A 50// 240 Hz690// 3540 /min cosQ 0,600,12// 0,58 kw S 1 3KALTL.150'CIP54 ! CL -F VDE 0530
Motor Nameplate Example :
Motor rated speedMotor rated frequencyMotor rated current 2.5 A
240 Hz3540 /min
Example Motor Nameplate -- Parameter Setting
1 >> 8Set all parameter to SK inverterSet the code switch position on the adapter to match the drive IDTurn off machine power install the inverter and adapter into machine and connect cableTurn on machine power observed signal lamp of adapter1st signal lamp indicate 24V DC power from SK inverter2nd and 3th signal lamp indicate the communication between PLC and adapter4th and 5th signal lamp indicate the communication between adapter and SK inverterDo not issue any instruction on the machine console to load program to the inverterThe adapter will not be respond the program and will generate an error message
Four important parameter must be careful to setIncorrect setting will cause motor overheating or damage
Motor rated voltage 400 V