C3S Securiglass clear run butt joint system€¦ · (*)Allowed by test according to BS 5234-2:1992...
Transcript of C3S Securiglass clear run butt joint system€¦ · (*)Allowed by test according to BS 5234-2:1992...
clea
r ru
n b
utt
join
t sy
stem
C3S Securiglassclear run butt joint system
clea
r ru
n b
utt
join
t sy
stem
C3S Securiglass Ltd.
Canal Mills, Elland Bridge, Elland, West Yorkshire HX5 0SQ
T: +44 (0)1422 376181 F: +44 (0)1422 310070
e-mail: [email protected] [email protected] www: c3ssecuriglass.com
A member of the C3S Group Ltd.
C3S Securiglass
Clear Run Butt Joint SystemClear Run Maximum Dimensions (top and bottom supported)
Legend for cables Allowed for dimension specified in the table
02
Linear Design Load (LDL)
Minimum Width Maximum Height, under linear design load of
0.50 0.75k 1.00k 1.5k 2.00k 3.00k 5.00k
Products (in mm) kN/m2 kN/m2 kN/m2 kN/m2 kN/m2 kN/m2 kN/m2
Pyrosec17 (30/30) 500 2900 2900 2900 2900(*) 1950 1550 NO
Pyrosec21EG (30/30) 500 2900 2900 2900 2900(*) 2100 1600 NO
Pyrosec27 (60/60) 500 2900 2900 2900 2900 2900 2900 1850
Pyrosec30 EG (60/60) 500 2900 2900 2900 2900 2900 2900 1950
(*)Allowed by test according to BS 5234-2:1992
Uniform Design Load (UDL)
Pyrosec17 (30/30) 500 2900 2900 2500 2300 2000 1800 1550
Pyrosec21EG (30/30) 500 2900 2900 2650 2400 2100 1900 4650
Pyrosec27 (60/60) 500 2900 2900 2900 2900 2900 2800 2400
Pyrosec30 EG (60/60) 500 2900 2900 2900 2900 2900 2850 2450
Concentrated Design Load (CDL)
Pyrosec17 (30/30) 500 2900 2250 1800 1450 NO NO NO
Pyrosec21EG (30/30) 500 2900 2400 1950 1500 NO NO NO
Pyrosec27 (60/60) 500 2900 2900 2900 2900 2050 1550 NO
Pyrosec30 EG (60/60) 500 2900 2900 2900 2900 2150 1600 NO
Pyrosec17 (30/30) 1000 2900 2900 2650 1650 1400 NO NO
Pyrosec21EG (30/30) 1000 2900 2900 2850 1800 1450 NO NO
Pyrosec27 (60/60) 1000 2900 2900 2900 2900 2050 1950 NO
Pyrosec30 EG (60/60) 1000 2900 2900 2900 2900 2150 2100 NO
Not Allowed
Uniform
Design Load
Linear
Design Load
Concentrated
Design Load
22
clea
r ru
n in
sula
tin
g f
ueg
o li
gh
t EI
30
bu
tt-j
oin
ted
scr
een
C3S Securiglass Ltd.
Canal Mills, Elland Bridge, Elland, West Yorkshire HX5 0SQ
T: +44 (0)1422 376181 F: +44 (0)1422 310070
e-mail: [email protected] [email protected] www: c3ssecuriglass.com
A member of the C3S Group Ltd.
C3S Securiglass
Clear Runinsulating fuego light EI 30 butt-jointed screenIn steel perimeter frame for periods of 30 minutes integrity and 30 minutes insulation
Diagrams are not to scale
22
1 Glass - type: 17mm thick C3S Securiglass laminated insulating fireresistant glass - dimensions: w.1600mm x h.2900mm.(Assessed).
2 Ceramic fibre tape (10mm wide x 3mm thick)
3 Silicone - Brand: Dow Corning - type: Firestop 70 or similar non combustible fire resistant silicone. (Available from C3S Securiglass).
• Test ref: 169764 & WF172975
• Steel frame Forster Fuego light in either 30mm or 50mm dimensions
clea
r ru
n in
sula
tin
g f
ueg
o li
gh
t EI
60
bu
tt-j
oin
ted
scr
een
C3S Securiglass Ltd.
Canal Mills, Elland Bridge, Elland, West Yorkshire HX5 0SQ
T: +44 (0)1422 376181 F: +44 (0)1422 310070
e-mail: [email protected] [email protected] www: c3ssecuriglass.com
A member of the C3S Group Ltd.
C3S Securiglass
In steel perimeter frame for periods of 60 minutes integrity and 60 minutes insulation
Diagrams are not to scale
22
1 Glass - type: 26mm thick C3S Securiglass laminated insulating fire resistant glass - dimensions: w.1320mm x h.2890mm or w.1100mm x h.3000mm
2 Ceramic fibre tape (10mm wide x 3mm thick)
3 Silicone - Brand: Dow Corning - type: Firestop 700 or similar non combustible fire resistant silicone. (Available from C3S Securiglass).
• Test ref: 169764 & WF172975
• Steel frame Forster Fuego light in either 30mm or 50mm dimensions
Clear Runinsulating fuego light EI 60 butt-jointed screen
22
C3S Securiglass
A timber perimeter framed system for periods of 30 minutes integrity and 30 minutes insulation
1 Perimeter framing - Meranti - outside dimensions of section:33mm x 77mm - density: 527kg/m3 (MV).
2 Concrete plug - steel - type: Hilti 100 HT - diameter: 10mm - length: 112mm.
3 Glass - type: 17.3mm thick C3S Securiglass laminated insulating fire resistant glass - dimensions: 1200mm x 2874mm - reference: BX10219-01-501.
4 Glazing bead - Meranti - outside dimensions of the section: 27mm x 25mm - density: 527kg/m3 (MV).
Clear Run insulating EI 30 butt-jointed timber screen
‘ ’
5 Screw - steel - diameter: 4mm - length: 50mm.
6 Setting block - type: Promatech-H, Hardwood or non-combustible - dimensions:70mm x 17mm x 6mm - density: 960kg/m3 (MV).
7 4mm thick closed cell foam tape.
8 Silicone - Brand: Dow Corning - type: Firestop 700 or similarnon combustible fire resistant silicone available from C3S.
9 Ceramic fibre tape (10mm wide x 3mm thick).
clea
r ru
n in
sula
tin
g E
I 30
bu
tt-j
oin
ted
tim
ber
scr
een
C3S Securiglass Ltd.
Canal Mills, Elland Bridge, Elland, West Yorkshire HX5 0SQ
T: +44 (0)1422 376181 F: +44 (0)1422 310070
e-mail: [email protected] [email protected] www: c3ssecuriglass.com
A member of the C3S Group Ltd.
Diagrams are not to scale
22
C3S Securiglass Ltd.
Canal Mills, Elland Bridge, Elland, West Yorkshire HX5 0SQ
T: +44 (0)1422 376181 F: +44 (0)1422 310070
e-mail: [email protected] [email protected] www: c3ssecuriglass.com
A member of the C3S Group Ltd.
Clear Run insulating EI 60 butt-jointed timber screenA timber perimeter framed system for periods of 60 minutes integrity and 60 minutes insulation
Diagrams are not to scale
22
‘ ’
1 Perimeter framing - Meranti - outside dimensions of section:33mm x 96mm - density: 431kg/m3 (MV).
2 Concrete plug - steel - type: Hilti 100 HT - diameter: 10mm - length: 112mm.
3 Glass - type: 26mm thick C3S Securiglass laminated insulating fire resistant glass - dimensions: 1200mm x 2874mm - reference: BX09789-01-501.
4 Glazing bead - Meranti - outside dimensions of the section: 27mm x 30mm - density: 431kg/m3 (MV).
clea
r ru
n in
sula
tin
g E
I 60
bu
tt-j
oin
ted
tim
ber
scr
een
5 Screw - steel - diameter: 4mm - length: 60mm.
6 Setting block - type: Promatech-H, Hardwood or non-combustible - dimensions:70mm x 26mm x 5mm - density: 960kg/m3 (MV).
7 4mm thick closed cell foam tape.
8 Silicone - Brand: Dow Corning - type: Firestop 700 or similarnon combustible fire resistant silicone available from C3S.
9 Ceramic fibre tape (10mm wide x 3mm thick).
C3S Securiglass
22
11
10
5
6
5
3
4
2
7
9
8
1
clea
r run
insu
latin
g Sc
hüco
AD
S 80
EI 3
0 bu
tt-jo
inte
d sc
reen
C3S Securiglass Ltd.
Canal Mills, Elland Bridge, Elland, West Yorkshire HX5 0SQ
T: +44 (0)1422 376181 F: +44 (0)1422 310070
e-mail: [email protected] [email protected] www: c3ssecuriglass.com
A member of the C3S Group Ltd.
C3S Securiglass
clear run insulating Schüco ADS 80 EI 30butt-jointed screenIn steel perimeter frame for periods of 30 minutes integrity and 30 minutes insulation
Diagrams are not to scale
22
113
1 Pyrobel 16
2 Dow Corning Firestop 700 or DC791T (5mm wide maximum) or Henkel Ceresit 3B capping to 2off. 10mm by 2mm ceramic fibre tape (4mm wide maximum)
The glass shall be glazed within a Schuco ADS80FR30 aluminium framed screen. Please consult theframe manufacturer for drawings of glazing system.
1 Hilti 100 HT - 10mm diameter x 112mm
2 Schuco Profile ref: 150 330
3 Clipped beads Schuco ref: 150 830
4 Schuco fireboard ref: 298 426
5 Setting block - 70mm by 17mm by 5mm
6 Schuco EPDM glazing gasket ref: 224 350
7 Schuco glazing gasket ref: 224 063
8 Setting block 100mm by 80mm by 15mm
9 Schuco intumescent strip ref: 298 400
10 Pyrobel 16 VL
11 Joint may comprise:Dow Corning Firestop 700 or DC719T - 5mm thick maximum or Henkel Ceresit 3B capping to2off. 10mm by 2mm ceramic fibre tape - 4mm maximum
22
11
10
5
6
5
3
4
2
7
9
8
1
clea
r run
insu
latin
g Sc
hüco
AD
S 80
EI 6
0 bu
tt-jo
inte
d sc
reen
C3S Securiglass Ltd.
Canal Mills, Elland Bridge, Elland, West Yorkshire HX5 0SQ
T: +44 (0)1422 376181 F: +44 (0)1422 310070
e-mail: [email protected] [email protected] www: c3ssecuriglass.com
A member of the C3S Group Ltd.
C3S Securiglass
clear run insulating Schüco ADS 80 EI 60butt-jointed screenIn steel perimeter frame for periods of 60 minutes integrity and 60 minutes insulation
Diagrams are not to scale
22
113
1 Pyrobel 16
2 Dow Corning Firestop 700 or DC791T (5mm wide maximum) or Henkel Ceresit 3B capping to 2off. 10mm by 2mm ceramic fibre tape (4mm wide maximum)
The glass shall be glazed within a Schuco ADS80FR30 aluminium framed screen. Please consult theframe manufacturer for drawings of glazing system.
1 Hilti 100 HT - 10mm diameter x 112mm
2 Schuco Profile ref: 150 330
3 Clipped beads Schuco ref: 150 830
4 Schuco fireboard ref: 298 426
5 Setting block - 70mm by 17mm by 5mm
6 Schuco EPDM glazing gasket ref: 224 350
7 Schuco glazing gasket ref: 224 063
8 Setting block 100mm by 80mm by 15mm
9 Schuco intumescent strip ref: 298 400
10 Pyrobel 16 VL
11 Joint may comprise:Dow Corning Firestop 700 or DC719T - 5mm thick maximum or Henkel Ceresit 3B capping to2off. 10mm by 2mm ceramic fibre tape - 4mm maximum