01 02 03 04 05 06 07 03 04 05 06 01 02 6 7 4 5 1 2 11 12 Auto Link Auto Link UPONOR C-35 CONTROL CENTRE Basic Dial Thermostat T-37 Optional Timer I-36 (When using T36 or dial T37 stats) 1 2 Digital Thermostat with Timer Functions T-38 Digital Thermostat T-36 1 2 1 2 1 2 Time zone 1 Time zone 2 No time control This terminal must be connected from the controller to a thermostat if a thermostat is used for this channel One of these three terminals must be connected from the Controller C-35 to a thermostat if a thermostat is used for this channel Fig.1 Controller (C-35) notes, The diagram below shows the Controller (C-35) linked to an optional Timer (I-36), five thermostats and ten 24V actuator heads. Only 6 of the 12 channels are shown for clarity. Each thermostat requires two cables to be wired to two of the four thermostat connections. The bottom connection must be made. The second wire should be connected to one of the three remaining terminals depending on whether the Timer (I-35) is being used and if so, which of the two time channels is being used. See Fig 1. Auto Link E L N POWER Connect to Switch Live (A) Switched Fuse Spur 3 Amp Fuse

description

https://www.uponor.co.uk/~/media/countryspecific/uk/support/c35.pdf?version=1

Transcript of C35

0102

0304

0506

07

0304

0506

0102

6745121112

Auto Link

Auto Link

UP

ON

OR

C-35 C

ON

TRO

L CEN

TRE

Basic

Dial

Thermostat

T-37

Optional Tim

erI-36

(When using

T36 or dial T37stats) 12

Digital

Thermostat

with Tim

erFunctions

T-38

Digital

Thermostat

T-36

12

12

12

Time zone 1

Time zone 2

No tim

e control

This terminal m

ust be connected from the controller to a

thermostat if a therm

ostat is used for this channel

One of these three term

inals must be

connected from the C

ontroller C-35 to a

thermostat if a therm

ostat is used for thischannel

Fig.1

Controller (C

-35) notes,The diagram

below show

s the Controller (C

-35) linked to an optional Timer (I-36), five therm

ostats and ten 24V actuator heads. O

nly 6 of the 12channels are show

n for clarity.E

ach thermostat requires tw

o cables to be wired to tw

o of the four thermostat connections. The bottom

connection must be m

ade. The secondw

ire should be connected to one of the three remaining term

inals depending on whether the Tim

er (I-35) is being used and if so, which of the tw

otim

e channels is being used. See Fig 1.

Auto Link

ELN

PO

WER

Connect to

Sw

itch Live(A

)

Sw

itchedFuseS

pur3 A

mp

Fuse