C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060...

111
Connected chromatography solutions 2019/2021 Chromatography Consumables Catalog

Transcript of C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060...

Page 1: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

Connected chromatography solutions2019/2021 Chromatography Consumables Catalog

Page 2: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

Find out more at thermofisher.com/chromatography

© 2019 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. AD72973-EN 0419S

Expect reproducible results with sample prep, columns and vials

The collective power of chromatography

Maximizing your chromatography productivity and achieving reproducible results requires optimizing the

whole workflow from sample to knowledge. By choosing the right tools, from your sample preparation

(manual or automated) to the highest selectivity column chemistry and cleanest vials, you maintain

sample integrity and achieve the highest instrument efficiency and reduce the need for costly reanalysis.

With the largest portfolio of sample handling; vials, plates and closures, column chemistries in a broad

range of dimensions and sample preparation, we remain a steadfast and committed partner in your

endeavor to improve the world around us.

UNITY LAB SERVICES

Find out more at thermofisher.com/chromatographyconsumables

Page 3: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

This PDF catalogue is designed to familiarise you with our comprehensive portfolio of Chromatography consumables, columns and accessories, designed to deliver connected chromatography solutions across Biopharma/Pharma, Food & Beverage, Environmental and Clinical workflows. We have included key workflows in the next few pages to help with your product selection.

How to use this PDF catalog

You can use the ‘ctrl F’ function to search for products, applications, brands or part numbers, or you can navigate by section using the contents page to guide you.

More information

For more information on Chromatography consumables, to access application notes, educational resources, selection guides and product literature, please visit thermofisher.com/chromatographyconsumables

Or, for more information on our Instrumentation and key applications, please visit thermofisher.com/chromatography

2019/2021 Chromatography Consumables Catalog

AppsLabGain access to our applications expertise on cloud-based Thermo Scientific™ AppsLab library of analytical applications for a comprehensive fully searchable method repository.

Visit appslab.thermofisher.com

A collaboration built for BiopharmaThe National Institute for Bioprocessing Research and Training (NIBRT) and Thermo Fisher Scientific are developing workflows using Thermo Fisher Scientific technology including the latest biomolecule columns.

For more information on collaboration built for BioPharma visit thermofisher.com/NIBRT

Page 4: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

Data

pro

cess

ing

Mass spectrometry

UHPLCVials & Closures

LC c

olu

mns

Sam

ple p

reparation

Thermo Scientific™

Biopharma workflow enablers

Charge variants CX-1 pH Gradient Buffers MAbPac™ SCX LC Columns ProPac™ Elite WCX LC Columns

Aggregates MAbPac SEC and MAbPac HIC LC Columns

Intact mass MAbPac RP LC Columns MAbPac SEC LC Columns ProPac Elite WCX LC Columns MAbPac SCX LC Columns MAbPac HIC LC Columns

Glycan analysis GlycanPac™ LC Columns Accucore Amide HILIC LC Columns

Peptide mapping SMART Digest Kits and SOLAµ Plates and Cartridges Accucore Vanquish

C18 LC Columns Accucore 150 C18 LC Columns Hypersil GOLD C18 LC Columns

Bioanalysis large molecules SMART Digest™ IA Kits and SOLAµ™ Plates and Cartridges Accucore™ Vanquish™ C18 LC Columns Acclaim™ LC Columns Hypersil GOLD™ C18 LC Columns

Find out more about consumables for your Biopharma workflow here

Page 5: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

Dattapppppppppppprrrrroooooooccccccccceeeeeeeeessssssssssssssssssssiiiiiiiiinnnnnnnnggggggggggggggg

Mass spectrometry

UHPL

C

SureStop™

Vials & Closures

LC c

olu

mns

GC columns

Sam

ple p

reparation

Thermo Scientific™

Pharmaceutical workflow enablers

Discovery DMPK HyperSep™ SPE Cartridges and Plates WebSeal™ Well Plates and Mats Accucore™ RP-MS LC Columns Accucore Biphenyl LC Columns Acclaim™ VANQUISH™ C18 UHPLC Columns Titan3™ Syringe Filters

Development DMPK / Pre Clinical SOLA™/SOLAμ™ SPE Plates and Cartridges WebSeal Well Plates and Mats HyperSep SPE Cartridges and Plates Accucore C18 LC Columns Accucore Biphenyl LC Columns Hypersil GOLD™ VANQUISH™ C18 UHPLC Columns

Clinical SOLA/SOLAμ SPE Plates and Cartridges WebSeal Well Plates and Mats Hypersil GOLD VANQUISH C18 UHPLC Columns Accucore C18 LC Columns Accucore Biphenyl LC Columns

QA/QC Titan3 Syringe Filters Hypersil GOLD C18 UHPLC Columns Accucore RP-MS LC Columns Accucore Biphenyl LC Columns TraceGOLD™ GC Columns

Discovery DMPK SMART Digest™ Kits WebSeal Well Plates and Mats MAbPac™ LC Columns ProPac™ Elite WCX LC Column GlycanPac™ LC Columns Acclaim 120 C18 Columns CX-1 pH Gradient Buffers

Small molecules Large molecules

Development DMPK / Pre Clinical SMART Digest & SMART Digest ImmunoAffinity Kit SOLA/SOLAμ SPE Plates and Cartridges WebSeal Well Plates and Mats Acclaim 120 C18 Columns

Clinical SOLA/SOLAμ SPE Plates and Cartridges WebSeal Well Plates and Mats Acclaim 120 C18 Columns

QA/QC Titan3 Syringe Filters SMART Digest Kits ProPac LC Columns MAbPac LC Columns CX-1 pH Gradient Buffers Acclaim 120 C18 Columns

Find out more about consumables for your Pharmaceutical workflow here

Page 6: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

L

Data processing

Mass spectrometry

UHPL

C

Vials & ClosuresLC

colu

mns

GC columns

Sam

ple p

reparation

Thermo Scientific™

Food and Beverage workflow enablers

Pesticides HyperSep™ SPE Cartridges QuEChERS TraceGOLD™ GC Columns GC Consumables and Accessories Accucore™ aQ LC Columns Acclaim™ Carbamate LC Columns Acclaim Trinity Q1 LC Columns

Contaminants by GC-MS HyperSep SPE Cartridges TraceGOLD GC Columns GC Consumables and Accessories

Mycotoxins HyperSep Retain Cartridges Accucore aQ LC Columns Hypersil GOLD™ LC Columns

Food quality/ Food labelling / Food fraud HyperSep Retain Cartridges HyperSep SPE Cartridges Acclaim LC Columns Accucore LC Columns HyperREX™ LC Columns GC Columns and Consumables

Veterinary drug residues QuEChERS Target2™ PTFE Syringe Filters Accucore VDX LC Columns

Find out more about consumables for your Food & Beverage workflow here

Page 7: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

Data

pro

cess

ing

Mass spectrometry

UHPLC or GC

Vials & Closures

LC o

r GC

colum

ns

Sam

ple p

reparation

Thermo Scientific™

Environmental workflow enablers

Persistent Organic Pollutants (POP) HyperSep™ Cartridges TraceGOLD™ GC Columns LinerGOLD™ GC Liners BTO Septa GC Consumables and Accessories

Volatile Organic Compounds (VOC) SPME Arrow TraceGOLD TG-VMS, TG-VRX, TG-624, TG-624SilMS, TG-VVOC B, TRACE™ TR-V1, TR-524, and TracePLOT GC Columns LinerGOLD Liners BTO Septa GC Consumables and Accessories

Microcystins HyperSep Cartridges Hypersil GOLD™ aQ LC Columns Accucore™ C18 LC Columns

Semi-Volatile Organic Compounds (SVOC) HyperSep Cartridges SPME Arrow TraceGOLD TG-XLBMS, TG-5SilMS, TG-PAH, TG-XLBMS, TG-OCP, TG-OPP TR-Pesticide, and TR-8270 GC Columns LinerGOLD Liners BTO Septa GC Consumables and Accessories

Find out more about consumables for your Environmental workflow here

Page 8: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

DDaattaapppppppppppprrrrroooooooooooooocccccccccceeeeeeeeeeessssssssssssssssssssssssssssssiiiiiiiiinnnnnnnnggggggggggggggg

Mass spectrometry

UHPL

C

SureStop™

Vials & Closures

LC c

olu

mns

GC columns

Sam

ple p

reparation

Thermo Scientific™

Clinical research workflow enablers

Forensic toxicology SOLA™/SOLAµ™ SPE Plates and Cartridges HyperSep™ SPE Cartridges and Plates HyperSep™ Retain Cartridges Accucore™ Biphenyl LC Columns Accucore RP-MS LC Columns TraceGOLD™ GC Columns and Guard Columns

Drugs of abuse research SOLA/SOLAμ SPE Plates and Cartridges HyperSep Verify CX Cartridges Accucore Biphenyl LC Columns Hypersil GOLD™ LC Columns TraceGOLD GC Columns

Supplement analysis HyperSep Retain Cartridges and Plates Hypercarb™ HPLC and UHPLC Columns Hypersil GOLD PFP LC Columns Accucore aQ C18 LC Columns

Amino acids, acylcarnitines, and succinylacetone research Hypersil GOLD C18 LC Columns Accucore aQ C18 LC Columns Acclaim™ HILIC LC Columns Titan3™ Syringe Filters HyperSep SLE Plates and Cartridges TraceGOLD GC Columns

Translational proteomics SMART Digest™ Kits SOLAμ SPE Plates and Cartridges EASY-Spray™ LC Columns PepMap™ RSLC Columns WebSeal™ Well Plates and Mats

Drug monitoring research SOLA/SOLAμ SPE Plates and Cartridges WebSeal Well Plates and Mats Acclaim 120 C18 Columns

Find out more about consumables for your Clinical workflow here

Page 9: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

Table of contents

Sample preparation products

Sample handling products

Bio LC columns and accessories

Section one

Section two

Section three

SMART Digest kits 1-003

SOLA SPE products 1-008

HyperSep SLE cartridges and plates 1-013

Microscale SPE plates and tips 1-015

HyperSep SPE cartridges and plates 1-017

SPE manifolds and accessories 1-026

HyperSep dispersive SPE (QuEChERS) 1-031

Syringes and filters 1-035

Vials and closures 2-003

AVCS closures and SureStop vials 2-004

Premium vials and closures 2-007

National vials and closures 2-013

MS certified vials 2-014

National vial reference chart 2-059

Chromacol vials and closures 2-060

Electronic crimping and decrimping tools 2-091

Well plates for chromatography 2-093

GC columns and accessories

Index

Section five

Gas management 5-005

Syringes for GC instruments 5-008

Injection port septa 5-015

Injection port liners 5-017

Ferrules 5-022

Capillary accessories 5-025

GC tools 5-030

TraceGOLD GC columns 5-034

TRACE GC columns 5-062

TracePLOT GC columns 5-074

GC reagents 5-077

Reacti-Therm heating, stirring and evaporation system 5-062

GC and GC-MS instruments 5-095Columns for biomolecules 3-003

MAbPac HPLC and UHPLC columns 3-005

LC columns for biomolecules 3-008

Columns for glycan analysis 3-020

ProPac HPLC columns 3-023

Silica based protein columns 3-031

Oligonucleotide columns 3-039

Nano, capillary and micro LC columns 3-044

LC columns and accessoriesSection four

Accucore Vanquish 4-003

Acclaim HPLC and UHPLC columns 4-032

Application Specific HPLC columns 4-045

Syncronis HPLC and UHPLC columns 4-058

Hypersil BDS and Hypersil Classical HPLC columns 4-066

LC accessories 4-077

LC reagents 4-098

Preparative HPLC columns 4-106

Page 10: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

Thermo Scientific GC columns and accessories are designed to give optimum system performance for today’s challenging analyses.

Thermo Scientific™ TraceGOLD™, Thermo Scientific™ TRACE™ and Thermo Scientific™ TracePLOT™ columns provide excellent quality and performance. Our range of GC accessories include all the tools needed by today’s gas chromatographers.

Featured products

GC columns and accessories

TraceGOLD GC columnsThe premium standard in GC column performance, delivering low bleed, excellent reproducibility and high levels of inertness.

Page 5-034

LinerGOLD GC linersThe GOLD standard in GC liner performance, providing enhanced inertness, leading to increased accuracy and precision in analysis.

Page 5-017

For more information, visit thermofisher.com/GCcolumns

Page 11: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

Section contents

GC

columns and accessories

Gas management 5-005

Syringes for GC instruments 5-008

Injection port septa 5-015

Injection port liners 5-017

Ferrules 5-022

Capillary accessories 5-025

GC tools 5-030

GC columns 5-033

TraceGOLD GC columns 5-034

TRACE GC columns 5-062

TracePLOT GC columns 5-074

GC reagents 5-077

Reacti-Therm heating, stirring and evaporation system 5-089

GC and GC-MS instruments 5-095

GC derivatization reagentsMaking the undetectable detectable. Thermo Scientific GC Derivatization reagents provide high levels of purity and reproducibility in analysis.

Page 5-077

Reacti-Therm sample derivatization systemHeating, stirring and evaporation in a single system, offering a complete solution for derivatization and other small-scale reactions.

Page 0895-002

Page 12: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-003

GC columns and accessoriesProduct selection guideSelection of the correct GC columns and accessories is critical to ensure optimum system performance. The selection guide below is designed to simplify this process

Vials and closures

GC septa

GC columnsGC ferrules

GC syringes

GC liners

Thermo Scientific GC consumables are available for both Thermo Scientific and Agilent instruments.

Page 13: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

thermofisher.com/GCparts 5-004

GC syringesSyringe selection by needle tip style

Syringe selection by needle gauge size• Gauge is a measure of the “thickness” of the needle• The higher the gauge number, the thinner the needle e.g. a 23

gauge is thicker than a 26 gauge

• Suffix “s” e.g. 23s refers to a needle with a narrower internal diameter

• For on-column injection ensure that the column ID is greater than the needle gauge

Needle Tip Style Features / Applications

Cone (Tapered tip)

Most versatile needle for autosampler use and resist coring of vial and inlet septa

Bevel (Sharp tip)

Typically used for manual injections. The tip shape helps reduce septa coring

Side Hole (Dome tip with a side hole for sample exit)

Usually used for headspace and large volume injections

Blunt End or 90º (flat top)

Used for injectors that do not contain an inlet septa such as Merlin MicroSeal™

Dual Gauge

Narrow gauge part suitable for megabore on-column injection. Wider part suitable for autosampler use

GC linersMaterial Uses Advantages Limitations100% Graphite

FID, NPD, high temperature

• Easy-to-use stable seal

• Higher temperature limit

• Can be easily removed

• Can be re-used

• Not for MS or oxygen- sensitive detectors

• Soft, easily deformed or destroyed

• Possible system contamination

85% Vespel / 15% Graphite

MS and oxygen-sensitive detectors

• Long lifetime • High temperature

limit • MS compatible

• Cannot be re-used

• Must be re-tightened after initial temperature cycles

Thermo Scientific™ SilTite™

MS and oxygen-sensitive detectors

• Long lifetime• High temperature

limit• MS compatible

• Cannot be re-used

GC ferrules

Vials and closures

GC columnsColumn Parameter

Parameters Affecting Resolution

Performance ChangesEfficiency Retention SelectivityColumn Length (m) 4 Doubling column length increases resolution by ~ 40%

Internal Diameter (mm) 4 4

The smaller the column ID, the greater the efficiency and better the resolution

Film Thickness (μm)

4The thicker the film, the greater the retention, e.g. ideal for highly volatile compounds. The thinner the film, the sharper the peaks and lower the bleed

Stationary Phase Chemistry 4 Altering the stationary phase can affect elution order and help separate closely, or co-eluting peaks

Material Max Operating Temperature Key Features

BTO 400 °C (330 °C for 17 mm size) Low bleedTR-Green 350 °C Long lifetime

Marathon 350 °CHigh mechanical durability

TR-Blue 200–250 °CEasy to penetrate for routine applications

GC septa

Nature of sample Vial Type Recommended

Routine samplesClear glass (with or without patch) as SureStop 9mm screw thread or 11mm crimp vial

Light sensitive samples

Amber glass (with or without patch) as SureStop 9mm screw thread or 11mm crimp vial

Low volume samplesMicro-Inserts or Microsampling and High Recovery vials with fixed inserts or reduced internal volume

Trace levels Silanized glass and/or Certified Kits

Ultra Trace MS analysis

MSCERT kits: The first low particle, low background chromatography vials, pre-cleaned to provide unmatched consistency; tested and certified for up to 15 critical physical characteristics affecting vial performance for mass spectrometry

Injection MethodInjection Requirements

Liner Requirements

Split

Enables rapid vaporization and effective mixing of sample

• Typically open-ended

• Large surface area & volume

• Design to aid mixing

• Low activitySplitless

Sample focused onto column – minimizes sample contact with reactive metal components

• Typically tapered• Small volume to

aid transfer• Low activity

PTV

Rapid heating and cooling, fast transfer to column-used for active compounds such as pesticides and large volume injections

• Small to aid sample transfer

• Good thermal properties for rapid heating & cooling

• Siltek coating provides highly inert surface

GC

columns and accessories

Page 14: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

Gas management

Filters For Gas Indicator Change

Filter Capacity (Click-On Inline)

Filter Capacity (Super Clean)

Moisture Inert carrier, He, H2, N2, AR, Air

21g H2O 7.2g H2O

Oxygen Inert carrier, He, H2, N2, AR 3L O2 1L O2

Hydrocarbon Inert carrier, He, H2, N2, AR, Air

36g (as n-butane) 24g (as n-butane)

Combi – Moisture, Oxygen Inert carrier, He, H2, N2, AR 10g H2O, 1.5L O2 –

Combi – Moisture, HydrocarbonsInert carrier, He, H2, N2, AR, Air

10g H2O, 18g HCs (as n-butane)

3.5g H2O, 12g HCs (as n-butane)

Triple – Moisture, Oxygen, Hydrocarbons

Inert carrier, He, H2, N2, AR

6g H2O, 1L O2, 12g HCs (as n-butane)

1.8g H2O, 500mL O2, 7g HCs (as n-butane)

Triple– Moisture, Oxygen, Hydrocarbons – He preconditioned for GC/MS

He 6g H2O, 1L O2, 12g HCs (as n-butane) –

Indicating Triple – Moisture, Oxygen, Hydrocarbons – He preconditioned for GC/MS

He

Moisture: Yellow to ClearOxygen: Green to Gray

0.1g H2O, 100mL O2, 0.07g HCs (as n-butane)

Click-on inline filters

Type Cat No. Quantity

Moisture Filter 60180-801 1 EachOxygen Filter 60180-802 1 EachHydrocarbon Filter 60180-803 1 EachCombi – Moisture, Oxygen 60180-804 1 EachCombi – Moisture, Hydrocarbons 60180-843 1 EachTriple – Moisture, Oxygen, Hydrocarbons 60180-805 1 EachTriple – Moisture, Oxygen, Hydrocarbons – He preconditioned for GC/MS 60180-806 1 EachIndicating Triple – Moisture, Oxygen, Hydrocarbons – He preconditioned for GC/MS 60180-808 1 Each

Connectors and accessories

Description Cat No. Quantity

Brass End Fitting, 0.125in. 60180-809 2 PackSteel End Fitting, 0.125in. 60180-810 2 PackBrass End Fitting, 0.25in. 60180-811 2 PackSteel End Fitting, 0.25in. 60180-812 2 PackDouble Ended Connector to connect Filter to Indicator 60180-813 1 EachReplacement O-Rings 60180-833 1 EachWall Mounting Clamp 60180-834 4 Pack

Thermo Scientific™ Click-On™ inline filtersEasy-to-use format eliminates contamination

• Pure gas output 99.9999% or 6.0 grade

• No carrier gas line contamination during filter change

• Easy and fast replacement without the need for tools

• TUEV approved

• Maximum pressure 11 bar (160 psi)

• Maximum flow 25L/min

5-005

Page 15: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

GC

columns and accessories

Super clean cartridge filtersReplace easily without tools

• 99.9999% pure gas (or 6.0 grade) output

• No carrier gas line contamination during cartridge change

• Cost effective

• TUEV approved

• Max. pressure 11 bar (160 psi)

• Max. flow 7L/min

Super clean cartridge filters

Type Base Included Cat. No. Quantity

Indicating Moisture Cartridge Filter No 60180-819 1 EachIndicating Oxygen Cartridge Filter No 60180-820 1 EachHydrocarbon Cartridge Filter No 60180-821 1 EachIndicating Combi Filter – Moisture, Hydrocarbons No 60180-826 1 EachIndicating Triple Filter – Moisture, Oxygen, Hydrocarbons No 60180-824 1 EachIndicating Triple Filter – Moisture, Oxygen, Hydrocarbons – He preconditioned for GC-MS No 60180-825 1 Each

Triple Filter – Moisture, Oxygen, Hydrocarbons – He preconditioned for GC-MS Yes 60180-830 1 Each

Indicating Triple Filter – Moisture, Oxygen, Hydrocarbons – He preconditioned for GC-MS Yes 60180-829 1 Each

3 Cartridge Pack – contains 1 x Triple Filter and 2 x Combi Filter (Moisture, Hydrocarbons) No 60180-822 1 Each

4 Cartridge Pack – contains 1 x Moisture Filter, 1 x O2 Filter and 2 x Hydrocarbon Filter Yes 60180-827 1 Each

3 Cartridge Pack – contains 1 x Triple Filter and 2 x Combi Filter (Moisture, Hydrocarbons) Yes 60180-828 1 Each

High Flow Pack of 2 x Hydrocarbon Filters for LC-MS – no Indicator No 60180-839 1 EachHigh Flow Pack of 2 x Moisture Filters for LC-MS – with Indicator No 60180-841 1 Each

Super clean cartridge filter baseplatesOne-time installation procedure

• Can be configured to the individual user requirements

• Needle valves ensure gas line is not contaminated during cartridge change

Filters are not included

Type For Use With For Gas

Single Base Triple Filter Carrier Gas OnlyDual Base 2 x Combi Filter Air and Fuel GasTriple Base Triple and 2 x Combi Filter Carrier, Make-Up, and Fuel GasFour-position Base Moisture, Oxygen, 2 x Hydrocarbon High Capacity Carrier, Fuel, Make UpTwo-position, High-flow Base N2 in LC/MS, H2O in H2/air generators Carrier, Make Up and Fuel

Super clean cartridge filter baseplates

Type Cat. No. QuantitySingle Base 60180-814 1 EachDual Base 60180-815 1 EachTriple Base 60180-817 1 EachFour-position Base 60180-818 1 EachO-rings for Base Plates 60180-837 20 PackFlush Cap 60180-838 2 Pack

thermofisher.com/chromatographyconsumables 5-006

Page 16: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

eVol XR dispensing systemAllows precise and accurate, operator-independent dispensing for better deployment of laboratory staff

• Can be calibrated easily by user to ensure validity of results

• Intuitive interface with touch wheel and full-color screen

• Complies to GLP and GMP protocols

• Improves confidence in reported results

• Unifies two precision devices, a digitally controlled electronic drive and an Thermo Scientific™ eVol™ XCHANGE™ analytical syringe

• Integrated XCHANGE coupling allows syringes to be quickly and easily changed

• XCHANGE syringes offer exceptional versatility and functionality

Applications:

• Routine dispensing of volatile solvents, hazardous, corrosive or viscous chemicals

eVol XR dispensing system

Description Cat. No. Quantity

Sample Dispensing System 66002-020 1 EacheVol XCHANGE Syringe 5μL 66002-021 1 EacheVol XCHANGE Syringe 50μL 66002-022 1 EacheVol XCHANGE Syringe 100μL 66002-038 1 EacheVol XCHANGE Syringe 500μL 66002-023 1 EacheVol XCHANGE Syringe 1000μL 66002-039 1 EachSample Dispensing System Kit* 66002-024 1 EacheVol Stand 66002-025 1 EachCharger for eVol System 66002-026 1 EachCharging Stand for eVol System 66002-027 1 EachReplacement Battery for eVol System 66002-028 1 EachReplacement Plunger for 5μL eVol Syringe 66002-029 1 EachReplacement Plunger for 500μL eVol Syringe 66002-031 1 EachReplacement Plunger for 1000μL eVol Syringe 66002-041 1 Each

* Sample Dispensing Kit contains 1 eVol XR unit, 1x5μL, 1x50μL and 1x500μL syringe.

Page 17: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

thermofisher.com/GCparts 5-008

GC

columns and accessories

Syringes for GC instrumentsProviding durability, clarity and accuracy for your sampleThermo Scientific syringes for GC instruments are designed to provide enhanced durability, clarity and accuracy in sample introduction. This gives confidence in analytical results, time-after-time.

Durability in your GC syringeThe enhanced design of the syringes delivers:

• Improved solvent resistance• Greater temperature range• Increased operational smoothness• Longer lifetime and improved cycle life

Clarity in your GC syringeSyringes are provided with a clear, easy-to-read black scale, which aids in consistent delivery of samples for manual syringes and easy identification of installed autosampler syringes.

Accuracy in your GC syringeThe enhanced design of the syringe has eliminated areas where the sample can become trapped and potentially cause carryover:

• Closer fit between the plunger tip and PTFE insert at the zero position

• Tighter fit between PTFE insert and glass barrel

• Improved fixed needle attachment

In addition, the reduction in adhesive from the fluid path enhances durability and reduces the risk of sample interaction with the adhesive.

Brand X Syringe

Thermo Scienti c GC Syringe

Classic DesignAdhesive in �uid path

susceptible to solvent attack resulting in

contamination and/or mechanical failure of

needle.

% Improvement in number of cycles versus a

competitor syringe.

Thermo Scienti c GC SyringeNo contact between sample and adhesive.

PTFE seal

Zero carryover potential.If adhesive is not �lled to the end it could lead to

potential carryover.

100%

1000%

Fixed Needle Attachment

Brand X Syringe

Thermo Scienti c GC Syringe

Classic DesignAdhesive in �uid path

susceptible to solvent attack resulting in

contamination and/or mechanical failure of

needle.

% Improvement in number of cycles versus a

competitor syringe.

Thermo Scienti c GC SyringeNo contact between sample and adhesive.

PTFE seal

Zero carryover potential.If adhesive is not �lled to the end it could lead to

potential carryover.

100%

1000%

Fixed Needle Attachment

Page 18: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

GC syringes for Thermo Scientific TriPlus RSH Autosampler

Fixed needle syringes

Volume (µL)Length (mm) Gauge Tip Style Type Cat. No. Quantity

5 85 23s Cone Merlin Valve SSL Injector: Splitless 365C0221 1 Each57 23s Cone SSL, PTV and Merlin Adapter 365C0231* 1 Each85 26s Cone Splitless and OC 365C0241 1 Each57 26s Cone SSL and PTV 365C0251* 1 Each

10 85 23s Cone Merlin Valve SSL Injector: Splitless 365D0261 1 Each57 23s Cone SSL, PTV and Merlin Adapter 365D0271* 1 Each85 26s Cone Splitless and OC 365D0281 1 Each57 26s Cone SSL and PTV 365D0291* 1 Each

Fixed needle, gas tight syringes

Volume (µL)Length (mm) Gauge Tip Style Type Cat. No. Quantity

10 85 23s Cone Merlin Valve SSL Injector: Splitless 365D0301 1 Each

57 23s ConeSSL, PTV and Merlin Adapter, especially suitable for volatile solvents or corrosive samples

365D0311* 1 Each

85 26s Cone Splitless and OC 365D0321 1 Each

57 26s ConeSSL, PTV and Merlin Adapter, especially suitable for volatile solvents or corrosive samples

365D0331* 1 Each

25 57 23s Cone SSL, PTV and Merlin Adapter 365F2441* 1 Each85 26s Cone Splitless and OC 365F2451 1 Each57 26s Cone SSL and PTV 365F2461* 1 Each

50 57 23s Cone Large Volume Injection, SSL 365G2311* 1 Each85 26s Cone LV OC 365G2321 1 Each

100 57 23s Cone Large Volume Injection, SSL 365H2141* 1 Each85 26s Cone LV OC 365H2151 1 Each

57 26s Cone Large Volume Injection, SSL w/o Merlin Adapter 365H2161* 1 Each

85 23 Side Hole Variable depth LV PTV (w & w/o Merlin) 365H2171 1 Each

57 23 Side Hole Large Volume Injection, PTV 365H2181* 1 Each250 85 26 Cone LV OC 365I2321 1 Each

57 26 Cone LV Splitless 365I2331 1 Each

85 23 Side Hole Variable depth LV PTV (w & w/o Merlin) 365I2341 1 Each

57 23 Side Hole LV PTV (with or without Merlin valve) 365I2351 1 Each500 85 26 Cone LV OC 365J2411 1 Each

57 26 Cone Sample Preparation, i.e. dilution, derivatization 365J2421 1 Each

57 23 Side Hole LV PTV (with or without Merlin valve) 365J2441 1 Each1000 65 23 Side Hole Headspace, up to 115 deg. 365Q2121 1 Each

57 22 LC Sample Preparation, i.e. dilution, derivatization 365K2811 1 Each

2500 65 23 Side Hole Headspace, up to 115 deg. 365Q2131 1 Each65 23 Side Hole Headspace, up to 150 deg. 365L2321 1 Each

5000 65 22 Side Hole Headspace up to 115 deg. 365Q2141 1 Each

10000 57 19 LC Sample Preparation, i.e. dilution, derivatization 365N2721 1 Each

* Also suitable for use with the Thermo Scientific™ TriPlus™ 100LS Autosampler

Removable needle syringes

Volume (µL)Length (mm) Gauge Tip Style Type Cat. No. Quantity

Repair Kit Cat. No. Quantity

0.5 57 23 Cone Split 365A0241* 1 Each 365RN617 1 Each1 57 23 Cone Split 365B0251* 1 Each 365RN656 1 Each

Page 19: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

Fixed needle, gas tight syringes

Volume (µL)

Length (mm) Gauge Tip Style Type Cat No. Quantity

Instrument Compatibility

10 50 23 Cone 365D3741 1 Each AS2000100 50 25 Bevel 365H2321 1 Each AS200/AS800250 50 25 Bevel 365I2561 1 Each AS200/AS800

Fixed needle syringes

Volume (µL)

Length (mm) Gauge Tip Style Type Cat No. Quantity

Instrument Compatibility

5 50 26 Cone Split/PTV 36504047 1 Each TriPlus

5 50 23 Cone 365C3701 1 EachAS3000, AS2000, AS200/AS800 AI/AS1310

5 50 26 Cone Split/PTV 36500505 1 Each AS3000, AS2000 AI/AS1310

5 80 26 Cone Splitless and OC 36502025 1 Each TriPlus

10 50 26 Cone 365D3711 1 Each AS3000, AS200, AS200/AS800

10 50 26 Cone 365D1856 6 Pack AS300, AS2000, AS200/AS800

10 50 25 Cone Split/PTV 36500525 1 EachTriPlus, AS3000, AS2000, AS200/AS800, AI/AS1310

GC

columns and accessories

GC syringes for Thermo Scientific instruments

Removable needle, gas tight syringes

Volume (µL)

Length (mm) Gauge Tip Style Type Cat No. Quantity

Replacement Needle Cat. No. Quantity

Instrument Compatibility

10 75 31 Cone Manual OC 36500520 1 Each 36550046 2 Pack

100 50 23 Side hole See Note 36520050 1 Each 36550040 2 Pack TriPlus,

AS200/AS800

100 50 23 Cone LV Splitless 36500495 1 Each 36566485 5 Pack

TriPlus, AS2000, AS200/AS800

250 80 26 Cone LVOC 36500490 1 Each 36566480 5 Pack TriPlus, AS2000

250 50 23 Side hole See Note 36520051 1 Each 36550040 2 Pack

TriPlus, AS2000, AS200/AS800

1000 50 23 Bevel 365K3041 1 Each 365RN235 5 Pack AS200/AS800

Removable needle syringes

Volume (µL)

Length (mm) Gauge Tip Style Type Cat No. Quantity

Replacement Needle Cat. No. Quantity

Instrument Compatibility

5 75 31 Cone Manual OC 36500510 1 Each 36550045 2 Pack

10 50 26 Cone 365D1841 1 Each 365RN362 2 Pack AS3000, AS2000

10 50 23 Cone 365D3731 1 Each 365RN372 2 PackAS3000, AS2000, AS200/AS800

50 50 23 Cone LV Splitless 36503015 1 Each 36566485 5 Pack AS2000

Syringe 36520051 is to be used when performing PTV/LVI injections with a dedicated liner for thermal labile compounds (liner 45352060). Compatible with Merlin Microseal device installed on BEST PTV and with AS2000 and TriPlus autosamplers for liquids.

Page 20: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-011

GC syringes for Agilent instruments

Fixed needle, gas tight syringes

Volume (µL)

Length (mm) Gauge Tip Style Cat. No. Quantity

10 42 23-26 Cone 365D0621 1 Each23-26 Cone 365D0626 6 Pack

Fixed needle syringes

Volume (µL)

Length (mm) Gauge Tip Style Cat. No. Quantity

5 42 23 Cone 365C0951 1 Each23 Cone 365C0956 6 pack23-26s Cone 365C0971 1 Each23-26s Cone 365C0976 6 pack

10 42 23 Cone 365D1571 1 Each23 Cone 365D1576 6 pack23-26s Cone 365D1621 1 Each23-26s Cone 365D1636 6 pack

Fixed needle, super-elastic plunger syringes

Volume (µL)

Length (mm) Gauge Tip Style Cat. No. Quantity

10 42 23-26s Cone 365D5416 1 Each

Removable needle syringes

Volume (µL)

Length (mm) Gauge

Tip Style Cat. No. Quantity

10 42 23 Cone 365D1611 6 Pack

Fixed needle syringes (Continued)

Volume (µL)

Length (mm) Gauge Tip Style Type Cat No. Quantity

Instrument Compatibility

10 50 23 Cone PTV/SSL Split 36520060 1 Each

AI/AS1310, TriPlus, AS300, AS2000, AS200/AS800

10 80 23 Cone Merlin ValveSSL Splitless 36520061 1 Each TriPlus, AS2000

10 50 23-26 Cone OC in PTVMerlin Valve

36500580 1 Each TriPlus, AS2000

10 80 26 Cone OC and Splitless 36502019 1 Each TriPlus, AS2000

Plunger-in-needle syringes

Volume (µL)

Length (mm) Gauge Tip Style Type Cat No. Quantity

Instrument Compatibility

0.5 50 23 Cone Split/PTV 36504045 1 Each AI/AS1310, TriPlus, AS3000

0.5 75 31 Cone Manual OC 36500500 1 Each

0.5 80 26 Cone Splitless and OC 36504046 1 Each TriPlus

Page 21: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

thermofisher.com/chromatographyconsumables 5-012

Removable needle syringes

Volume (µL)

Length (mm) Gauge

Tip Style Cat. No. Quantity

Replacement Needle Cat. No. Quantity

5 42 26s Cone 365C6610 1 Each23s Cone 365RN661 2 Pack

42 26s Cone 365D6610 1 Each 365RN272 2 Pack23s Cone 365D6620 1 Each

GC syringes for Shimadzu instruments

Fixed needle, gas tight syringes

Volume (µL)

Length (mm) Gauge Tip Style Cat. No. Quantity

10 50 23 Cone 365D2976 6 Pack26 Cone 365D2977 1 Each23 Cone 365D3741 1 Each

25 50 23 Cone 365F3761 1 Each100 50 23 Cone 365H3771 1 Each250 50 26 Cone 365H6700 1 Each1000 50 26 Side Hole 365K8135 1 Each2500 50 26 Side Hole 365L8635 1 Each

Fixed needle syringes

Volume (µL)

Length (mm) Gauge Tip Style Cat. No. Quantity

5 50 23 Cone 365C3701 1 Each26 Cone 36500505 1 Each

10 50 26 Cone 365D3711 1 Each23 Cone 36520060 1 Each26 Cone 365D1856 6 Pack23 Cone 365D2971 6 Pack

GC

columns and accessories

GC syringes for CTC instruments

Removable needle syringes

Volume (µL)

Length (mm) Gauge

Tip Style Cat. No. Quantity

Replacement Needle Cat. No. Quantity

10 50 23 Cone 365D3731 1 Each 365RN372 2 Pack26 Cone 365D1841 1 Each 365RN362 2 Pack

Learn more at thermofisher.com/GCparts

Page 22: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-013

Manual GC syringes

Removable needle, gas tight syringes

Volume a(µL)

Length (mm) Gauge

Tip Style Cat. No. Quantity

Replacement Needle Cat. No. Quantity

10 50 26s Bevel 365D0811 1 Each 365RN215 5 Pack25 50 25 Bevel 365F1931 1 Each 365RN225 5 Pack

22s Blunt End 365FLG31 1 Each 365RNL25 5 Pack

50 50 22s Blunt End 365GLG41 1 Each 365RNL25 5 Pack

500 50 25 Bevel 365J2881 1 Each 365RN225 5 Pack

22s Blunt End 365JLG71 1 Each 365RNL25 5 Pack

1000 50 23 Bevel 365K3041 1 Each 365RN235 5 Pack

22s Blunt End 365KLG81 1 Each –

5000 50

22 Bevel 365M5212 1 Each –

22s Blunt End 365M6322 1 Each –

22s Side Hole 365M8922 1 Each –

10000 50 22 Bevel 365N5214 1 Each

22s Side Hole 365N8923 1 Each 365RN465 2 Pack

Removable needle syringes

Volume (µL)

Length (mm) Gauge

Tip Style Cat. No. Quantity

Replacement Needle Cat. No Quantity

10 50 26 Bevel 365D1171 1 Each 365RN215 5 Pack25 50 25 Bevel 365F1901 1 Each 365RN225 5 Pack50 50 25 Bevel 365G2091 1 Each 365RN225 5 Pack

Fixed needle, gas tight syringes

Volume (µL)

Length (mm) Gauge Tip Style Cat. No. Quantity

10 50 26 Bevel 365D4433 1 Each26s Blunt End 365D6314 1 Each

25 50 22s Blunt End 365F6315 1 Each50 50 25 Bevel 365G2111 1 Each

22s Blunt End 365G6316 1 Each100 50 25 Bevel 365H2321 1 Each

22s Blunt End 365H6317 1 Each250 50 25 Bevel 365I2561 1 Each500 50 25 Bevel 365J2831 1 Each

22s Blunt End 365J6319 1 Each1000 50 22 Bevel 365K3051 1 Each

Fixed needle syringes

Volume (µL)

Length (mm) Gauge Tip Style Cat. No. Quantity

5 50 26 Bevel 365C0741 1 Each10 50 26 Bevel 365D1091 1 Each

26 Bevel 365D1096 6 Pack25 50 25 Bevel 365F1891 1 Each100 50 25 Bevel 365H2291 1 Each

Page 23: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

thermofisher.com/chromatographyconsumables 5-014

GC

columns and accessories

PTFE Luer-Lok, gas tight syringes

Volume (µL) Cat. No. QuantityNeedle Cat. No. Quantity

25 365F7655 1 Each 365RNL22 2 Pack50 365G7656 1 Each 365RNL22 2 Pack100 365H7657 1 Each 365RNL22 2 Pack250 365I7658 1 Each 365RNL22 2 Pack500 365J7659 1 Each 365RNL22 2 Pack1000 365KL531 1 Each 365RNL22 2 Pack2500 365LL541 1 Each 365RNL22 2 Pack5000 365ML551 1 Each 365RNL22 2 Pack10000 365NL561 1 Each 365RNL22 2 Pack25000 365PL571 1 Each 365RNL22 2 Pack

Please note that the Luer-Lok syringes do not come with a needle and therefore the needle part number needs to be ordered separately

Luer tip, gas tight syringes

Volume (µL) Cat. No. Quantity

100 365H7814 1 Each1000 365K7817 1 Each2500 365L7818 1 Each5000 365M7819 1 Each10000 365N7820 1 Each

Page 24: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-015

Injection port septaQuality materials for all applications

BTO septa• Low bleed septa - ideal for

MS applications• Excellent mechanical properties• Maximum temperature 400°C

TR-Green septa• Long injection lifetime• Low injection port adhesion• Maximum temperature 350°C

Marathon septa• Pre-pierced for reliable

performance• Up to 400 injections per septa• Maximum temperature 350°C

TR-Blue septa• General purpose septa• Easy to penetrate• Maximum temperature 200-

250°C

Septa

Material ID (mm)Cat. No. (Blister Pack)

Quantity (Blister Pack)

Cat. No. (Glass Jar)

Quantity (Glass Jar)

BTO 9 31303240-BP 50 Pack 31303240 50 PackBTO 11 31303233-BP 50 Pack 31303233 50 PackBTO 11.5 31303230-BP 50 Pack 31303230 50 PackBTO 12.7 31303250-BP 48 Pack 31303228 50 PackBTO 17 31303215-BP 48 Pack 31303211 50 PackTR-Green 9 313G3240-BP 50 Pack 313G3240 50 PackTR-Green 11 313G3230-BP 50 Pack 313G3230 50 PackTR-Green 12.7 – 48 Pack 313G3228 50 PackTR-Green 17 313G3215-BP 48 Pack 313G3211 50 PackMarathon 9 313P3240-BP 50 Pack 313P3240 50 PackMarathon 11 313P3233-BP 50 Pack 313P3233 50 PackMarathon 11.5 313P3230-BP 50 Pack 313P3230 50 PackMarathon 17 313P3215-BP 48 Pack 313P3211 50 PackTR-Blue 9 N/A N/A 313B3240 50 PackTR-Blue 11 N/A N/A 313B3233 50 PackTR-Blue 11.5 N/A N/A 313B3230 50 PackTR-Blue 17 N/A N/A 313B3211 50 Pack

thermofisher.com/GCparts

Learn more at thermofisher.com/GCparts

Page 25: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

thermofisher.com/chromatographyconsumables 5-016

Gold and siltek inlet base seals• Precision machined to provide exceptional sealing properties

• Gold plating and Siltek coatings provide a surface with exceptional inertnessfor analysis of highly active compounds

• High grade stainless steel providing reproducible seal

• Compatible with Thermo Scientific TRACE 1300 Series GC & Agilentsplit/splitless injection ports

Gold inlet base seals

For Use With ID (mm) Cat. No. Quantity

Single Column Installation 0.8 290GA081 10 PackSingle Column Installation 0.8 290GA082 2 PackSingle Column Installation (Cross Version) 0.8 290GA084 10 Pack

Single Column Installation (Cross Version) 0.8 290GA083 2 Pack

Dual Column Installation 1.2 290GA121 10 PackDual Column Installation 1.2 290GA122 2 Pack

Siltek inlet base seals

For Use With ID (mm) Cat. No. Quantity

Single Column Installation 0.8 290GA091 10 PackSingle Column Installation 0.8 290GA092 2 PackSingle Column Installation (Cross Version) 0.8 290GA094 10 Pack

Single Column Installation (Cross Version) 0.8 290GA093 2 Pack

GC

columns and accessories

Page 26: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

LinerGOLD GC linersThe GOLD standard in GC liner performance

• Increased accuracy and sensitivity in analysis – LinerGOLD prevents the loss of sensitive compounds in analysis

• Lower detection limits – when analyzing active and sensitive compounds

• Excellent reproducibility – gives confidence in your results from liner to liner – setting the GOLD standard

The GOLD standard in liner consistencyConsistency in your GC liner is of paramount importance – you expect to see a consistently high level of performance time after time. Thermo Scientific™ LinerGOLD™ GC liners are manufactured and tested to ensure that you have confidence with every liner that it installed onto your GC system.

Mass 28, nitrogen

Mass 18, water

0

2

4

6

8

10

12

0 1 2 3 4 5 6 7 8

Minutes

Abun

danc

e (%

)Av

erag

e Br

eakd

own

%

Figure 1: Endrin and DDT breakdown test results showing the lot-to-lot reproducibility and low levels of inertness of LinerGOLD

Figure 2: Compound degradation after 50 injections – LinerGOLD exhibits minimal breakdown

0 5 10 15 20 25 30 35 40 45 500

5

10

15

20

Injection number

Breakdown limit (%)

% D

DT B

reak

dow

n

0 5 10 15 20 25 30 35 40 45 500

5

10

15

20

Injection number

Breakdown limit (%)

% E

ndrin

Bre

akdo

wn

0 5 10 15 20 25 30 35 40 45 500

5

10

15

20

Injection number

Breakdown limit (%)

% D

DT B

reak

dow

n

0 5 10 15 20 25 30 35 40 45 500

5

10

15

20

Injection number

Breakdown limit (%)

% E

ndrin

Bre

akdo

wn

Injection port liners

5-017

Learn more at thermofisher.com/GCparts

Page 27: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

LinerGOLD GC liners for Thermo Scientific TRACE 1300 series and Agilent instruments, SSL injector

Injection TypeID x OD (mm)

Length (mm) Packing

Cat. No.5 Pack

Cat. No.25 Pack

Split/Splitless Liner4 x 6.3 78.5 Quartz Wool 453A2265-UI 453A1262-UI

Split/Splitless Straight Liner 4 x 6.3 78.5 No 453A1295-UI 453A2292-UI

Splitless/Split Liner with Single Taper 4 x 6.3 78.5 No 453A1345-UI 453A2342-UI

Splitless/Split Liner with Single Taper 4 x 6.3 78.5 Quartz Wool 453A1925-UI 453A2922-UI

Splitless Liner with Double Taper 4 x 6.3 78.5 No 453A1355-UI 453A2352-UI

Precision Split/Splitless Liner 4 x 6.3 78.5 Quartz Wool 453A1255-UI 453A1252-UI

Direct Straight Liner1 x 6.3 78.5 No 453A1335-UI 453A2332-UI

LinerGOLD Mixed Liner Pack 1 x 6.3 Mixed Mixed 453TH002-UI N/A

LinerGOLD GC liners for Thermo Scientific TRACE Ultra and FOCUS instruments

Injection TypeID x OD (mm)

Length (mm) Packing

Cat. No.5 Pack

Cat. No.25 Pack

Direct Straight Liner5 x 8 105 No 45350030-UI 45354030-UI

Split Straight Liner3 x 8 105 No 45350031-UI 45354031-UI

Splitless Liner3 x 8 105 No 45350032-UI 45354032-UI

Splitless Liner5 x 8 105 No 45350033-UI 45354033-UI

Precision Liner5 x 8 105 Quartz Wool 453T1905-UI 453T4905-UI

Splitless Precision Liner5 x 8 105 Quartz Wool 453T2999-UI 453T4999-UI

Baffled PTV Liner 2 x 2.75 120 No 453T2845-UI 453T4845-UI

GC

columns and accessories

thermofisher.com/chromatographyconsumables 5-018

Page 28: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-019

Injection port liners for Thermo Scientific instruments Highly deactivated and produced to exacting tolerances to ensure a high degree of reproducibility

Liners for Thermo Scientific TRACE 1300 series and TRACE ULTRA PTV instruments, PTV injector

Injection Type ID x OD (mm)

Length (mm) Packing

Cat. No.2 Pack

Cat. No.5 Pack

Cat. No.25 Pack

PTV Straight Liner 1 x 2.75 120 No N/A 45352054 N/A

PTV Straight Liner 2 x 2.75 120 No N/A 45352057 45354057

PTV Straight Liner (deactivated) 2 x 2.75 120 No 45322045 N/A N/A

PTV Liner with Sintered Lining 1 x 2.75 120 No N/A 45352060 N/A

PTV Liner with Three Baffles 1 x 2.75 120 No N/A 45352062 N/A

PTV Siltek Metal Liner 1 x 2.75 120 No 45322046 N/A N/A

PTV Siltek Metal Liner 2 x 2.75 120 No 45322044 N/A N/A

PTV Siltek Metal Liner 2 x 2.75 120 Wool 45322056 N/A N/A

PTV Baffle Liner (Siltek) 2 x 2.75 120 No N/A 453T2120 N/A

PTV Split Liner with Recessed Gooseneck

2 x 2.75 120 Quartz Wool N/A 45352070 N/A

PTV Silcosteel Liner for OC 1 x 2.75 120 No 45322052 N/A N/A

Liners for Thermo Scientific TRACE 1300 series SSL instruments and Agilent instruments, SSL injector

Injection Type ID x OD (mm)

Length (mm) Packing

Cat. No. 5 Pack

Cat No.25 Pack

Direct Straight Liner 1.2 x 6.3 78.5 No 453A1335 453A2332

Split Straight Liner 4 x 6.3 78.5 Quartz Wool 453A2265 453A1262

Split Straight Liner 4 x 6.3 78.5 No 453A1295 453A2292

Split/Splitless FocusLiner 4 x 6.3 78.5 Quartz Wool 453A1255 453A1252

Split/Splitless FocusLiner with Single Taper 4 x 6.3 78.5 Quartz

Wool 453A1315 453A1312

Split/Splitless Liner with Single Taper 4 x 6.3 78.5 No 453A1345 453A2342

Split/Splitless Liner with Double Taper 4 x 6.3 78.5 No 453A1355 453A2352

Split/Splitless Liner w/ Recessed Gooseneck 4 x 6.3 78.5 Quartz

Wool 453A1305 N/A

Splitless Liner with Single Taper 4 x 6.3 78.5 Quartz

Wool 453A1925 N/A

Split/Splitless Mini-Lam Liner 4 x 6.3 78.5 No 453A2009 N/A

Split/Splitless Mixed Liner Sample Pack Mixed Mixed Mixed 453TH002 N/A

Learn more at thermofisher.com/GCparts

Page 29: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

thermofisher.com/chromatographyconsumables 5-020

Liners for Thermo Scientific TRACE ULTRA and FOCUS SSL instruments, SSL injector

Injection Type

ID x OD (mm)

Length (mm) Packing

Cat. No. 5 Pack

Cat No.25 Pack

Split Straight Liner 5 x 8 105 No 45350030 45354030

Split Straight Liner 3 x 8 105 No 45350031 45354031

Split Straight Liner 5 x 8 105 CarboFrit 453T2131 N/A

Splitless Straight Liner 3 x 8 105 No 45350032 45354032

Splitless Straight Liner 5 x 8 105 No 45350033 45354033

Splitless Straight Liner 5 x 8 105 CarboFrit 453T2130 N/A

Splitless Straight Liner (Siltek) 3 x 8 105 No 453T2121 N/A

Split FocusLiner for 50mm Needle 5 x 8 105 Quartz

Wool 453T1905 453T4905

Splitless FocusLiner for 50mm Needle 5 x 8 105 Quartz

Wool 453T2999 453T4999

Splitless FocusLiner for 70mm Needle 5 x 8 105 Quartz

Wool 453T2895 453T4895

Split/Splitless Straight Liner 0.75 x 2.75 105 No 45352083 N/A

Liner sealing rings for Thermo Scientific instruments

Description Cat. No. Quantity

Liner Sealing Ring for TRACE 1300 Series GC SSL Injector 29001320 5 Each

Liner Sealing Ring for TRACE 1300 Series GC PTV Injector 29001318 1 Each

Liner sealing Ring for TRACE and FOCUS GC SSL Injector 29033406 10 Pack

Liner sealing Ring for TRACE PTV Injector 29013417 2 Pack

GC

columns and accessories

Page 30: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-021

Liner sealing rings for Agilent instrument

Description Cat. No. Quantity

Graphite Liner Sealing Ring for Agilent Direct Straight Liners 290GA242 10 Pack

Graphite Liner Sealing Ring for Agilent SSL Liners 290GA243 10 PackGraphite Liner Sealing Ring for Agilent 2.0mm Liners 290GA244 10 PackViton Liner Sealing Ring for Agilent SSL Injector 290OA241 10 Pack

Thermo Scientific GC consumables are suitable for use with Agilent GC systems

Injection port liners for Agilent instruments

Liners for Agilent instruments

Injection Type ID x OD (mm)

Length (mm) Packing

Cat. No. 5 Pack

Cat No.25 Pack

Direct Straight Liner 1.2 x 6.3 78.5 No 453A1335 453A2332

Split Straight Liner 4 x 6.3 78.5 Quartz Wool 453A2265 453A1262

Split Straight Liner 4 x 6.3 78.5 No 453A1295 453A2292

Split/Splitless FocusLiner 4 x 6.3 78.5 Quartz Wool 453A1255 453A1252

Split/Splitless FocusLiner with Single Taper 4 x 6.3 78.5 Quartz

Wool 453A1315 453A1312

Split/Splitless Liner with Single Taper 4 x 6.3 78.5 No 453A1345 453A2342

Split/Splitless Liner with Double Taper 4 x 6.3 78.5 No 453A1355 453A2352

Split/Splitless Liner w/ Recessed Gooseneck 4 x 6.3 78.5 Quartz

Wool 453A1305 N/A

Split/Splitless FAST FocusLiner 2.3 x 6.3 78.5 Quartz Wool 453A1285 453A2282

Split/Splitless FAST FocusLiner with Single Taper 2.3 x 6.3 78.5 Quartz

Wool 453A2375 453A1372

Splitless Liner with Single Taper 4 x 6.3 78.5 Quartz Wool 453A1925 N/A

Splitless Straight Liner 2.0 x 6.3 78.5 No 453A2275 N/A

Splitless Liner with Recessed Gooseneck 2.0 x 6.3 78.5 No 453A2325 N/A

Single Gooseneck (Deactivated Metal) 5.2 x 6.3 78.5 No 453A2001 N/A

Cyclosplitter Liner (Deactivated Metal) 5.2 x 6.3 78.5 No 453A2002 N/A

Split/Splitless Liner with Wool (Deactivated Metal) 5.2 x 6.3 78.5 No 453A2003 N/A

Split/Splitless Mixed Liner Sample Pack Mixed Mixed No 453AG001 N/A

Learn more at thermofisher.com/GCparts

Page 31: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

thermofisher.com/chromatographyconsumables 5-022

100% Graphite

15% Graphite/

85% Vespel SilTiteSuitable for Thermo Scientific TRACE ULTRA SSL Injector • •

Suitable for Thermo Scientific TRACE 1300/1310 & Agilent SSL Injectors

• • •

Suitable for Thermo Scientific TRACE ULTRA non-MS detectors • •

Suitable for Thermo Scientific TRACE 1300/1310 & Agilent non-MS detectors

• •

Suitable for all Thermo Scientific & Agilent MS Detectors • •

Suitable for Thermo Scientific PTV Injector • •

FerrulesWide range of choices for a wide range of instruments and applications

100% Graphite FerrulesThermo Scientific 100% graphite ferrules are a soft material that is

porous to oxygen, making them suitable for most applications except GC-MS interface connections. These easy-to-use ferrules form a soft grip with the column and provide a stable seal.

15% Graphite / 85% Vespel FerrulesThe mechanically robust 15% Graphite/

85% Vespel ferrules have a long lifetime and are compatible with GC-MS. These ferrules form a strong grip with the column and cannot be reused as they form a permanent seal with the column. They have a temperature limit of 350°C, but must be re-tightened after initial temperature cycles.

SilTite Metal FerrulesThe SilTite ferrule forms a strong, permanent, airtight seal

around the capillary column, eliminating leaks. The base of the ferrule is flat and forms a perfect seal with the MS interface. The ferrule’s temperature tolerance is well above the limit of the injector, MS interface or GC oven. Unlike other ferrules, SilTite Ferrules do not need re-tightening after installation.

Please also see syringes on page 5-008.

All varieties of ferrules are supplied in contaminant-free, individual blister packs, allowing removal of an individual item without risk of contamination to the other supplied items.

Thermo Scientific ferrules are available in three different materials and various dimensions to match the instrument and capillary column ID. The choice of material is dependent upon the use; guidelines are given in the table.

To select the most appropriate ferrule for your GC system, refer to the table below:

Material TypeSuitable for GC-MS Temp Limit (°C) Re-usable

Graphite No 450 YesGraphite/Vespel Yes 350 NoStainless Steel (SilTite) Yes 500 No

GC

columns and accessories

Page 32: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

For Use with Material TypeFerrule Size (Column ID) (mm) Cat. No. Quantity

Thermo Scientific TRACE 1300/1310 SSL injectors and non-MS detectors

100 % Graphite 0.1-0.32 290GA139 10 Pack0.45-0.53 290GA140 10 Pack

15% Graphite/85% Vespel 0.1-0.25 290VA191 10 Pack

0.32 290VA192 10 Pack0.53 290VA193 10 Pack

Capillary Column Nut for injectors and non-MS Detectors Stainless Steel 35050458 5 Pack

Thermo Scientific TRACE Ultra SSL injectors and non-MS detectors

100 % Graphite 0.1-0.25 29053488 10 Pack0.32 29053487 10 Pack0.53 29053486 10 Pack

15% Graphite/85% Vespel 0.1-0.25 29033461 10 Pack

0.32 29033460 10 Pack0.53 29033471 10 PackPacked Column 1/8" OD 290VT168 10 PackPacked Column 1/4" OD 290VT165 10 Pack

15% Graphite/85% Vespel (3.4mm length)

0.1-0.25 290VT186 10 Pack*0.32 290VT187 10 Pack*0.53 290VT188 10 Pack*

Capillary Column Nut for Graphite/Vespel Ferrules Brass 290BT239 2 Pack

All Thermo Scientific PTV injectors 100 % Graphite 0.1-0.25 29053488 10 Pack

0.32 29053487 10 Pack0.53 29053486 10 Pack

Thermo Scientific MS detectors 15% Graphite/85% Vespel 0.1-0.25 29033496 10 Pack

0.32 29033497 10 Pack

Capillary Column Nut for MS Detector

Brass 290BT240 5 PackStainless Steel 290BT241 5 Pack

Thermo Scientific MS detectors VESPEL SCP-5000 0.1-0.25 290VT221 5 Pack

Capillary Column Spring Loaded Nut for MS Detectors

Stainless Steel for ISQ/TSQ 1R120434-0010 1 Pack

Stainless Steel for QE GC/Exactive GC 1R120434-0020 1 Pack

SilTite Kit for Thermo Scientific TRACE 1300/1310 GC SSL injectors

SilTite Metal 0.1-0.25 290MA215 1 Each**

0.32 290MA216 1 Each**

0.53 290MA217 1 Each**SilTite Kit for Thermo Scientific ISQ GC-MS interface

SilTite Metal 0.1-0.25 290MA194 1 Each**0.32 290MA195 1 Each**0.53 290MA196 1 Each**

Replacement SilTite Ferrules for Thermo Scientific TRACE 1300/1310 SSL and ISQ GC-MS interface kits

SilTite Metal 0.1-0.25 290MA201 10 Pack0.32 290MA202 10 Pack

0.53 290MA203 10 Pack

SilTite Nuts for MS interface 290MA205 5 PackSilTite Nuts for SSL injectors 290MA207 5 PackSilTite Kits for Thermo Scientific DSQ GC-MS interface

SilTite Metal 0.1-0.25 290MT229 1 Each**0.32 290MT230 1 Each**0.53 290MT231 1 Each**Replacement SilTite Nuts 290MT211 5 Pack

Replacement SilTite Ferrules for Thermo Scientific DSQ GC-MS interface kits

SilTite Metal 0.1-0.25 290MT221 10 Pack0.32 290MT222 10 Pack0.53 290MT223 10 Pack

* Vespel Ferrules must be used in conjunction with brass nut part number 290BT239** SilTite Kits contain 2 SilTite nuts and 10 ferrules

Ferrules for Thermo Scientific instruments

Page 33: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

thermofisher.com/chromatographyconsumables 5-024

Ferrules for Agilent instruments

For Use with Material TypeFerrule Size (Column ID) (mm) Cat. No. Quantity

Agilent injectors and non-MS detectors

100 % Graphite 0.1-0.32 290GA139 10 Pack0.45-0.53 290GA140 10 PackPacked Column 1/8" OD 290GA108 10 PackPacked Column 1/4" OD 290GA107 10 Pack

15% Graphite/85% Vespel 0.1-0.25 290VA191 10 Pack

0.32 290VA192 10 Pack0.53 290VA193 10 PackPacked Column 1/8" OD 290VT168 10 PackPacked Column 1/4" OD 290VT165 10 Pack

Capillary Column Nut for injectors and non-MS Detectors

Stainless Steel 35050458 5 Pack

Agilent MS detectors 15% Graphite/85% Vespel 0.1-0.25 29033496 10 Pack

0.32 29033497 10 Pack0.53 290VP144 10 Pack

SilTite Kits for Agilent SSL injectors SilTite Metal 0.1-0.25 290MA215 1 Each*

0.32 290MA216 1 Each*0.53 290MA217 1 Each*

SilTite Nuts for MS interface 290MA205 5 PackSilTite Kit for Agilent MS detectors

SilTite Metal 0.1-0.25 290MA194 1 Each**0.32 290MA195 1 Each**0.53 290MA196 1 Each**

Replacement SilTite Ferrules for all SilTite Kits

SilTite Metal 0.1-0.25 290MA201 10 Pack0.32 290MA202 10 Pack0.53 290MA203 10 Pack

SilTite Nuts for SSL injectors 290MA207 5 PackReplacement Baseplate Seals 290MA227 2 Pack

290MA228 10 Pack

Thermo Scientific GC consumables are suitable for use with Agilent GC systems* Kit contains 2 nuts, 10 ferrules and 2 base seals** Kit contains 2 nuts and 10 ferrules

GC

columns and accessories

Page 34: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-025

SilTite µ-Union kits, ferrules and replacement unions

Column ID (mm) 2nd Column ID (mm)

SilTite µ-Union Kit Cat. No. (1 Each)

SilTite µ-Union Ferrules Cat. No. (10 Pack)

SilTite µ-Union Replacement Union Cat. No. (1 Each)

0.1 – 0.25 0.1-0.25 290SM301 290SM401 290SM3210.32 290SM302 290SM402 290SM3210.53 290SM303 290SM403 290SM322

0.32 0.32 290SM304 290SM404 290SM3210.53 290SM305 290SM405 290SM322

SilTite capillary column connectors and ferrules

Column ID (mm) 2nd Column ID (mm)

SilTite Column Connector Kit Cat. No. (1 Each)

SilTite Ferrules Cat. No. (10 Pack)

Replacement SilTite Connector Nuts* Cat. No. (5 Pack)

0.1-0.25 0.1-0.25 290MU498 290MF229 290MN2110.32 0.32-0.53 290MU499 290MF230 290MN2110.53 0.45-0.53 290MU500 290MF231 290MN211

* SilTite nuts must be used with SilTite ferrules

SilTite µ-UnionThe tiny connection for GC Columns

The SilTite µ-Union is a connector for GC capillary columns, giving zero dead volume. The product has low thermal mass – it is only 9mm in length and has a mass <0.5g. It is available in kits to connect columns from 0.1mm ID to 0.53mm ID.

• Zero dead volume – giving optimized peak shapes

• FingerTite technology – easy to install and leak-free

• Highly inert and robust

Each SilTite µ-Union kit contains the following:

• 5 x ferrules

• 2 x union fittings

• Installation jigs

• Installation instructions

GC capillary connectors

Description Cat. No. Quantity

Universal Capillary Connector 64000-001 1 EachY Capillary Connector 64000-002 1 Each

SilTite capillary column connectorsFor use with capillary GC columns

• For fused silica capillary columns

• Glass lined for inertness

• Low thermal mass

• Each pack contains 1 Connector, 2 Nuts and 5 Ferrules

Capillary accessories

thermofisher.com/GCparts

Page 35: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

thermofisher.com/chromatographyconsumables 5-026

Finger tite connectorsEasier fit, reliability and leak-free connections

• No need to re-tighten ferrules as they expand and contract with the fitting

• Easy to handle with the nut touchable even with a hot injector/detector

• No tools required

Finger tite connectors for TRACE 1300 series GC and Agilent GCs

Description Cat. No. Quantity

Split/Splitless and MS Starter Kit 290SA131 1 EachSplit/Splitless and FID Starter Kit 290SA132 1 EachSplit/Splitless Injector Base Seal 290SA133 2 PackFerrules for 0.1-0.25mm ID Columns 290S1132 10 PackFerrules for 0.32mm ID Columns 290S1131 10 Pack

Finger tite connectors for TRACE GC Ultra and FOCUS GCs

Description Cat. No. Quantity

Female Nut 290ST130 5 PackSplit/Splitless and MS Starter Kit 290ST131 1 EachSplit/Splitless and FID Starter Kit 290ST132 1 EachFerrules for 0.1-0.25mm ID Columns 290S1132 10 PackFerrules for 0.32mm ID Columns 290S1131 10 Pack

Retention gap kitsSupport Thermo Scientific gas chromatography consumables

• Kit contains one union and five ferrules

• Length of deactivated fused silica tubing

Deactivated silica tubing

Description Cat. No. Quantity

Deactivated silica tubing, 0.32mm ID; 2m Length 260G498P 1 EachDeactivated silica tubing, 0.53mm ID; 2m Length 260G499P 1 Each

Deactivated silica tubing, 0.25mm ID; 5m Length 260G495P 1 Each

Deactivated silica tubing, 0.32mm ID; 5m Length 260G496P 1 EachDeactivated silica tubing, 0.53mm ID; 5m Length 260G500P 1 EachDeactivated silica tubing, 0.53mm ID; 1m Length (Siltek) 260G401P 1 Each

Retention gap kits

Description Cat. No. QuantityReplacement Union Cat. No. Quantity

Retention Gap Kit, 0.22 – 0.32mm ID, 2m 260RG497 1 Each 290GU498 1 EachRetention Gap Kit, 0.53mm ID, 2m 260RG499 1 Each 290GU499 1 EachRetention Gap Kit, 0.53mm ID, 5m 260RG500 1 Each 290GU499 1 Each

GC

columns and accessories

Page 36: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-027

Capillary GuardGOLD and HydroGOLD columnsProviding protection to the analytical column

• Protects against column contamination caused by non-volatile materials, extending the column lifetime

• Focuses target analytes at the head of the analytical column, leading to better chromatographic peak shape

• Highly deactivated to provide superior inertness, essential for analysis of active compounds

• HydroGOLD extends column lifetime by preventing degradation from harsh “steam-cleaning” water injections

Capillary Thermo Scientific™ GuardGOLD™ and HydroGOLD columns

ID (mm) Length (m)

GuardGOLD Cat. No. Quantity

HydroGOLD Cat. No. Quantity

0.18 2 26050-0218 1 Each 26H50-0218 1 Each0.25 2 26050-0225 1 Each 26H50-0225 1 Each0.32 2 26050-0232 1 Each 26H50-0232 1 Each0.53 2 26050-0253 1 Each 26H50-0253 1 Each0.18 5 26050-0518 1 Each 26H50-0518 1 Each0.25 5 26050-0525 1 Each 26H50-0525 1 Each0.32 5 26050-0532 1 Each 26H50-0532 1 Each0.53 5 26050-0553 1 Each 26H50-0553 1 Each0.18 10 26050-1018 1 Each 26H50-1018 1 Each0.25 10 26050-1025 1 Each 26H50-1025 1 Each0.32 10 26050-1032 1 Each 26H50-1032 1 Each0.53 10 26050-1053 1 Each 26H50-1053 1 Each

Capillary column end capsFeature a universal fit to all GC capillary columns

• Eliminate column contamination caused by leaving a column unsealed or sealed with a septum

• Color-coordinated fittings ensure that the column is reinstalled the same way it came out

• Reusable

Capillary column end caps

Description Cat No. Quantity

Capillary Column End Caps, Paired 260EC111 10 Pack

Learn more at thermofisher.com/GCparts

Page 37: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

thermofisher.com/chromatographyconsumables 5-028

SWAP-IT GC-MS interface systemEasy to install for quick column changeovers

The SWAP-IT GC-MS Interface provides a powerful tool for switching capillary columns without the need to vent the MS

• Specially deactivated, robust stainless steel transfer capillary provides an interface between the analytical column and the MS detector

• Small ID of transfer capillary ensures exposure to air and water is reduced to a minimum during disconnection of the analytical column

• The system works without the requirement for additional He-purge

• Finger-tight connections make exchanging the analytical column quick and easy without the need for tools

SWAP-IT GC-MS Interface system

Description Cat. No. Quantity

For Thermo Scientific Instruments (ISQ GC-MS, TSQ 8000 GC-MS/MS)SWAP-IT GC-MS Interface Kit: SWAP-IT GC-MS Interface, Nuts, Ferrules, Accessories 60180-791 1 EachFor Thermo Scientific Instruments (DSQ GC-MS, DSQ II GC-MS, PolarisQ GC-MS, ITQ GC-MS only)SWAP-IT GC-MS Interface Kit: SWAP-IT GC-MS Interface, Nuts, Ferrules, Accessories 60180-790 1 EachSWAP-IT GC-MS Interface, SWAP-IT only 60180-792 1 EachTransfer Line Nut 290SG001 1 EachGraphite/Vespel Ferrule for Transfer Line 290SG020 10 PackFor Agilent InstrumentsSWAP-IT GC-MS Interface Kit: SWAP-IT GC-MS Interface, Nuts, Ferrules, Accessories 60180-794 1 EachSWAP-IT GC-MS Interface, SWAP-IT Only 60180-796 1 EachTransfer Line Nut 290SG004 1 EachGraphite/Vespel Ferrule for Transfer Line 290SG021 10 PackSWAP-Tight Nut and Adaptor for S/SL Injector 290SG003 1 EachAccessoriesSWAP-Tight Nut 290SG002 1 EachSWAP-Tight Ferrules, Blank 290SG000 10 PackSWAP-Tight Ferrules, 0.1 – 0.25mm 290SG025 10 PackSWAP-Tight Ferrules, 0.32mm 290SG032 10 Pack

Mass 28, nitrogen

Mass 18, water

0

2

4

6

8

10

12

0 1 2 3 4 5 6 7 8Minutes

Abun

danc

e (%

)

Removal of water and nitrogen to levels less than 2% is obtained within 3-4 minutes after column replacement

GC

columns and accessories

Page 38: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-029

3-Port SilFlow deviceSwitch your GC column without the need to vent

• Allows column switching in GC-MS without the need to vent

• Utilizes a make up gas module and a microfluidic device

• SilTite FingerTite fittings for easy set up and a reliable seal

3-Port SilFlow device

Description Cat. No. Quantity

3 Port SilFlow MCD (0.25/0.32) 60201-398 1 Each

3-Port SilFlow repacement parts

Description Cat. No. Quantity

SilFlow Fingertight Ferrules for 0.25mm ID Columns 29063466 10 PackSilFlow Fingertight Ferrules for 0.32mm ID Columns 29063467 10 PackSilFlow Fingertight Tool 60201-401 1 EachSilFlow Nuts 290SF302 10 PackBlanking Ferrule 290ST414 5 Pack170µm Deactivated Tubing 0.363mm OD 60cm Length 60201-390 1 Each75µm Untreated Fused Silica Tubing 0.363mm OD 30cm Length 60201-391 1 Each

170µm Deactivated Tubing 0.363mm OD 120cm Length 60201-394 1 Each

75µm Untreated Fused Silica Tubing 0.363mm OD 80cm Length 60201-395 1 Each

GC tubing

Material OD (in) ID (in)Length (ft) Cat. No. Quantity

Copper 1/8 0.065 50 60181-632 1 Each1/4 0.19 50 60181-633 1 Each

Stainless Steel 1/16 0.01 25 60181-634 1 Each

0.02 25 60181-635 1 Each0.03 25 60181-636 1 Each0.04 25 60181-637 1 Each

1/8 0.085 25 60181-638 1 Each1/4 0.21 25 60181-639 1 Each

GC tubingGC tubing for plumbing GC systems

Page 39: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

thermofisher.com/chromatographyconsumables 5-030

GC tools Support GC applications

GC tools

Description Cat. No. Quantity

Straight-Tipped Forceps 60180-770 1 EachAngle-Tipped Forceps 60180-771 1 Each0.35mm Drill Bit 60180-779 1 Each0.45mm Drill Bit 60180-780 1 Each0.70mm Drill Bit 60180-781 1 EachAdjustable Spanner 60180-782 1 EachShortix Capillary Column Cutter 60180-835 1 EachShortix Capillary Column Cutter Repair Kit 60180-836 1 EachCeramic Column Cutter 60201-318 1 Each

GC tool kitsIncludes: Wrench sets, flashlight, brushes, mini-drill set and other tools for maintaining your GC system performance

GC tool kits

Description Cat. No. Quantity

Capillary Tool Kit for Thermo Scientific GCs 60180-784 1 EachCapillary Tool Kit for Agilent GCs 60180-786 1 Each

GC installation kit

GC installation kit

Description Cat. No. Quantity

GC Installation Kit 60180-888 1 Each

GC

columns and accessories

Includes:

• Tubing cutter

• 1/8 x 1/4in. reamer

• 7/16in. wrench

• 1/2in. wrench

• 1/8in. brass tees, 4

• 1/8in. brass nuts, 10

• Brass front and back ferrules, 10

• 15.2m instrument-grade, cleaned 1/8in. copper tubing

Page 40: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-031

GLD pro gas leak detectorAids in quickly locating and identifying gas leaks

The Thermo Scientific™ GLD Pro Gas Leak Detector is specifically designed for use with gas chromatography instruments. Detection of leaks allows the user to reduce detector noise, provide a stable baseline, reduce carrier gas by minimizing waste, and maximize the lifetime of the analytical column by minimizing the presence of oxygen and other impurities in the carrier gas.

• Suitable for detection of a wide range of laboratory gases

• Push button on/off switch

• Push button zero function

• Automatic shutoff (5 minutes)

• LED light indicator for intensity of leak

• Rechargeable battery (up to 6 hrs. operation)

• Durable storage case

• Probe holder

• One year warranty

GLD Pro gas leak detector

Description Cat. No. Quantity

GLD Pro Leak Detector 66002-001 1 EachSmall Probe Adaptor 66002-003 1 EachSoft-Sided Carry Case (Leak Detector not included) 66002-002 1 Each

Green LED and all 3 yellow LEDs and audible

continuous alarm; signi�cant leak detected

Green LED and 4 red LEDs;

small leak detected

Green LED and all 7 red LEDsand audible continuous alarm;

signi�cant leak detected

Green LED only;no leak detected

Probe

Reference

1:1

Learn more at thermofisher.com/GCtools

Page 41: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

thermofisher.com/chromatographyconsumables 5-032

GC

columns and accessories

GFM pro electronic flowmeterMeasure and monitor flow quickly and efficiently

The Thermo Scientific™ GFM Pro Flowmeter is specifically designed for use with gas chromatography instruments. This versatile product is an electronic device capable of measuring volumetric flow for all types of gases. Real-time measurements can be made for various types of flow paths including continually changing gas types. The unit is portable so it can be hand-held or it also has an optional stand for bench-top convenience.

• Compact ergonomic design features side grips for added durability

• Easy-to-use interface features over-range warning indicator and auto-shutoff

• Measurement range of 0.5-500mL/min

• Accuracy of +/- 2% of flow or +/- 0.2mL/min, whichever is greater

• Data output via USB port

• Calibration: traceable to NIST primary standards

• Explosion-proof rating for flammable and explosive gases

• CE certified

• Uses 2-AA batteries

• Re-calibration service available

GFM Pro electronic flowmeter

Description Cat. No. Quantity

GFM Pro Flowmeter 66002-010 1 EachSoft-Sided Carry Case (Flowmeter not included) 66002-002 1 EachGFM Pro Flowmeter Re-Calibration 66002-GFMCAL 1 Each

0.00

+0.50mL/min +500mL/min

Display reads“under range”

Display reads(+) �ow values

Display reads(-) �ow values

Positive �ow range

Page 42: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-033

A comprehensive column range providing excellent quality and performance, with guaranteed reproducibility

Get reliable, reproducible results for GC and GC-MS with our comprehensive portfolio of GC columns that meet all of your analytical needs.

TraceGOLD• Offering a leap forward in column

performance delivering low bleed and superior inertness

TRACE• For excellent quality and reproducibility for a

wide range of applications

UltraFast • Short, narrow-bore columns for use with the

Thermo ScientificTM UltraFastTM instrument

TracePLOT • Providing reproducible analyses of

permanent gases, hydrocarbons and solvents

GC columns

For more information visit thermofisher.com/GCcolumns

Page 43: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

GC

columns and accessories

TraceGOLD GC columns

TraceGOLD GC columns offer you a leap forward in column performance delivering low bleed and superior inertness ideally suited to MS applications.

TG-1MS 035

TG-5MS 036

TG-5SilMS 037

TG-5MS AMINE 038

TG-5HT 039

TG-SQC 040

TG-35MS 041

TG-35MS AMINE 042

TG-1301MS 043

TG-624 043

TG-624SilMS 045

TG-1701MS 046

TG-17MS 047

TG-17SilMS 048

TG-225MS 049

TG-200MS 050

TG-WaxMS 051

TG-WaxMS A 052

TG-WaxMS B 053

TG-POLAR 054

TG-XLBMS 055

TG-VRX 056

TG-VMS 057

TG-OCP I / TG OCP II 058

TG-OPP I / TG-OPP II 059

TG-ALC Plus I / TG-ALC Plus II 060

TG-Dioxin 061

Page 44: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-035

POLAR

for Standard Columns 430°C for Metal Columns

d p

TraceGOLD TG-1MS GC columnsExceptionally low bleed for optimal signal-to-noise ratio, sensitivity and MS integrity

• Non-polar

• Equivalent to USP G2

TraceGOLD TG-1MS GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.10 10 0.1 26099-0200 1 Each0.20 12 0.33 26099-5820 1 Each0.15 20 0.15 26099-2760 1 Each

40 0.15 26099-2940 1 Each0.18 20 0.18 26099-5780 1 Each0.25 15 0.25 26099-1300 1 Each

0.5 26099-2110 1 Each1.0 26099-2840 1 Each

30 0.25 26099-1420 1 Each0.5 26099-2230 1 Each1.0 26099-2960 1 Each

30 with 5m SafeGuard 0.25 26099-1425 1 Each60 0.25 26099-1540 1 Each

0.5 26099-2350 1 Each1.0 26099-3080 1 Each

0.32 15 0.25 26099-1310 1 Each1.0 26099-2850 1 Each

30 0.25 26099-1430 1 Each0.5 26099-2240 1 Each1.0 26099-2970 1 Each3.0 26099-4840 1 Each

60 0.25 26099-1550 1 Each0.5 26099-2360 1 Each1.0 26099-3090 1 Each

0.53 15 0.5 26099-2130 1 Each1.0 26099-2860 1 Each1.5 26099-3340 1 Each

30 0.5 26099-2250 1 Each1.0 26099-2980 1 Each1.5 26099-3360 1 Each

30 with 5m SafeGuard 1.0 26099-2985 1 Each

Applications:• Hydrocarbons• Solvent impurities• PCB congeners• Aroclor mixes• Simulated distillation• Drugs of abuse• Natural gas odorants• Essential oils• Pesticides

Similar to: • Rxi-1ms• DB-1• DB-1ms• HP-1• HP-1ms• Ultra-1• SPB-1• Equity-1• VF-1ms• CP-Sil 5 CB Low Bleed/MS

TraceGOLD TG-1MT Metal GC columns

ID (mm) Length (m)Film Thickness (µm) Cat. No. Quantity

0.25 15 0.25 26M99-1300 1 Each30 0.25 26M99-1420 1 Each

0.53 5 0.1 26M99-4130 1 Each0.88 26M99-4120 1 Each

6 0.15 26M99-4100 1 Each

Page 45: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-036thermofisher.com/chromatographyconsumables

GC

columns and accessories

TraceGOLD TG-5MS GC columnsThe most widely used MS phase in gas chromatography

• Low polarity phase

• Low bleed for excellent signal-to-noise ratio, sensitivity and mass spectral integrity

• Exceptional inertness ideal for analysis of active compounds

• Equivalent to USP G27 phase

POLAR

for Standard Columns 430°C for Metal Columns

Applications:• Semi-volatiles• Phenols• Amines• Residual solvents and solvent

impurities• Drugs of abuse• Pesticides• PCB cogeners• Aroclor mixes

Similar to: • Rxi-5ms• DB-5• HP-5• HP-5ms• Ultra-2• SPB-5• Equity-5• CP-Sil 8

TraceGOLD TG-5MS GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.10 10 0.1 26098-0200 1 Each0.15 20 0.15 26098-2760 1 Each

40 0.15 26098-2940 1 Each0.18 20 0.18 26098-5780 1 Each

20 with 5m SafeGuard 0.18 26098-5785 1 Each0.25 15 0.25 26098-1300 1 Each

15 with 5m SafeGuard 0.25 26098-1305 1 Each30 0.25 26098-1420 1 Each

0.5 26098-2230 1 Each1.0 26098-2960 1 Each

30 with 5m SafeGuard 0.1 26098-0475 1 Each0.25 26098-1425 1 Each

60 0.25 26098-1540 1 Each0.5 26098-2350 1 Each1.0 26098-3080 1 Each

0.32 15 1.0 26098-2850 1 Each30 0.25 26098-1430 1 Each

0.5 26098-2240 1 Each1.0 26098-2970 1 Each

30 with 5m SafeGuard 0.25 26098-1435 1 Each60 0.25 26098-1550 1 Each

0.5 26098-2360 1 Each1.0 26098-3090 1 Each

0.53 0.5 26098-2130 1 Each1.0 26098-2860 1 Each1.5 26098-3340 1 Each

30 0.25 26098-1440 1 Each0.5 26098-2250 1 Each1.0 26098-2980 1 Each1.5 26098-3360 1 Each

60 5.0 26098-4100 1 Each

TraceGOLD TG-5MT Metal GC columns

ID (mm) Length (m)Film Thickness (µm) Cat. No. Quantity

0.25 15 0.1 26M98-0350 1 Each0.25 26M98-1300 1 Each

30 0.25 26M98-1420 1 Each60 0.25 26M98-1540 1 Each

Page 46: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-037

TraceGOLD TG-5SilMS GC columnsIncorporate phenyl groups in the polymer backbone for improved thermal stability, reduced bleed and reduced susceptibility to oxidation

• Low polarity, silarylene phase

• Designed for low bleed and outstanding inertness

Applications:• GC-MS applications using

ion-trap systems• Polycyclic aromatics• Hydrocarbons including

chlorinated hydrocarbons• Phthalates• Phenols• Amines• Organophosphate

Similar to:• DB-5ms Ultra Inert• VF-5ms• CP-Sil 8 Low-Bleed/MS• Rxi-5SilMS• BPX5• ZB-5ms• Optima-5MS• SLB-5

POLAR

5% phenyl / 95% dimethyl arylene polysiloxane

TraceGOLD TG-5SilMS GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.15 20 0.15 26096-2760 1 Each0.18 20 0.18 26096-5780 1 Each0.25 15 0.25 26096-1300 1 Each 15 with 10m SafeGuard 0.25 26096-1301 1 Each

30 0.25 26096-1420 1 Each0.5 26096-2230 1 Each1.0 26096-2960 1 Each

30 with 5m SafeGuard 0.25 26096-1425 1 Each0.5 26096-2235 1 Each

30 with 10m SafeGuard 0.25 26096-1421 1 Each60 0.25 26096-1540 1 Each

1.0 26096-3080 1 Each0.32 30 0.25 26096-1430 1 Each

0.5 26096-2240 1 Each1.0 26096-2970 1 Each

0.53 30 1.5 26096-3360 1 Each

Learn more at thermofisher.com/GCcolumns

Page 47: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-038thermofisher.com/chromatographyconsumables

GC

columns and accessories

TraceGOLD TG-5MS AMINE GC columnsAnalysis of ppm levels of amines without column priming

• Low polarity phase, base optimized

• Tubing surface is chemically altered to reduce tailing of active basic compounds

• Also allows analysis of neutral or weakly acidic compounds (e.g. phenols) and compounds susceptible to hydrogen bonding

• Low bleed at maximum operating temperature

Applications:• Amines and other basic

compounds, including alkylamines, diamines, triamines, ethanolamines

• Nitrogen-containing heterocyclics

Similar to:• Rtx-5 Amine

POLAR

300°C / 315°C

Modi�ed 5% diphenyl / 95% dimethyl polysiloxane for basic compounds

TraceGOLD TG-5MS AMINE GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 15 0.25 26097-1300 1 Each1.0 26097-2840 1 Each

30 0.25 26097-1420 1 Each0.5 26097-2230 1 Each1.0 26097-2960 1 Each

0.32 30 1.0 26097-2970 1 Each0.53 30 1.0 26097-2980 1 Each

3.0 26097-3960 1 Each

1 23

4

5

6

7

8

9

10

12

13

11

2 4 6 8 10Minutes

TG-5MS Amine 30m x 0.32mm x 1.0µmTemperature: 120°C to 220°C at 10°C/minuteDetector Type: FIDCarrier Gas: HydrogenFlow Rate: 40cm/minInjection Volume: 1.0µLInjection Mode: Split 25:1, 300°C

1. diethylamine2. pyridine3. morpholine4. phenol5. aniline6. 2-chlorophenol7. diethylenetriamine

8. octylamine9. 1-methyl-2-pyrrolidone10. 2-nitrophenol11. 2,6-dimethylaniline12. nicotine13. 2-nitroaniline

Amines and phenols

Page 48: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-039

TraceGOLD TG-5HT GC columnsOffers extended operation up to 400°C, ideal for high temperature extended GC applications

• Low polarity

• Lower bleed and better inertness than comparable high-temperature columns

• Special design of fused silica tubing extends column lifetime by up to 40%

Applications:• Phenols• Residual solvents• Solvents• Semivolatiles• Pesticides• PCBs• Solvent impurities

Similar to: • Rxi-5HT• BP-5HT• VF-5HT• ZB-5HT

POLAR

5% diphenyl / 95% dimethyl polysiloxane

TraceGOLD TG-5HT GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 15 0.1 26095-0350 1 Each0.25 26095-1300 1 Each

30 0.1 26095-0470 1 Each0.25 26095-1420 1 Each

0.32 15 0.1 26095-0360 1 Each30 0.1 26095-0480 1 Each

0.25 26095-1430 1 Each0.53 10 0.15 26095-1640 1 Each

30 0.15 26095-0620 1 Each

Learn more at thermofisher.com/GCcolumns

Page 49: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-040

GC

columns and accessories

TraceGOLD TG-SQC GC columnsEnsure the quality of a Thermo Scientific instrument when installed on site

• Optimized for system qualification tests for new GC-MS installations or during service/maintenance of an existing instrument

• We recommend reserving this column for benchmark testing only

POLAR

Applications:• System Qualification Tests

(Thermo Scientific GC-MS)

TraceGOLD TG-SQC GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 15 0.25 26070-1300 1 Each30 0.25 26070-1420 1 Each

thermofisher.com/chromatographyconsumables

Page 50: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-041

POLAR

35% diphenyl / 65% dimethyl polysiloxane

TraceGOLD TG-35MS GC columnsHigher phenyl content for useful elution order and retention time changes

• Mid-polarity phase

• Equivalent to USP G42 phase

Applications:• Organochlorine pesticides

and herbicides• Pharmaceuticals• PCB cogeners• Aroclor mixes• Sterols• Rosin acids• Phthalate esters

Similar to:• Rtx-35• BP-35• HP-35• SPB-35• SPB-608

TraceGOLD TG-35MS GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 15 0.25 26094-1300 1 Each30 0.25 26094-1420 1 Each

0.5 26094-2230 1 Each0.32 30 0.25 26094-1430 1 Each

0.5 26094-2240 1 Each0.53 15 0.5 26094-2130 1 Each

30 1.0 26094-2980 1 Each1.5 26094-3360 1 Each

Learn more at thermofisher.com/GCcolumns

Page 51: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-042thermofisher.com/chromatographyconsumables

GC

columns and accessories

TraceGOLD TG-35MS AMINE GC columnsChemically altered tubing surface reduces tailing and eliminates the need for column priming

• Mid-polarity phase, base optimized

• Developed for analysis of active basic compounds without derivatization

• Also allows analysis of neutral compounds and adsorptive compounds with oxygen groups susceptible to hydrogen bonding

• Low bleed at maximum operating temperature

Applications:• Amines including alkylamines,

diamines, triamines and ethanolamines

• Nitrogen-containing heterocyclics

Similar to: • Rtx-35 Amine

220°C

Modi�ed 35% diphenyl / 65% dimethylpolysiloxane for basic compounds

POLAR

TraceGOLD TG-35MS AMINE GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 30 0.5 26092-2230 1 Each

1.0 26092-2960 1 Each 0.32 30 1.0 26092-2970 1 Each

1.5 26092-3350 1 Each0.53 15 1.0 26092-2860 1 Each

30 1.0 26092-2980 1 Each

1

2/3

4

5

67

8

9

0.50 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5Minutes

Primary amines

TG-35MS AMINE 30m x 0.53mm x 1.0µmTemperature: 35°C (5 minute hold) IsothermalDetector Type: FIDCarrier Gas: HeFlow Rate: 35cm/secInjection Volume: 1.0µLInjection Mode: Split (10:1), 250°C

1. methylamine2. dimethylamine3. trimethylamine4. ethylamine5. isopropylamine

6. tert-butylamine7. n-propylamine8. diethylamine9. sec-butylamine

Page 52: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-043

POLAR

6% cyanopropyl phenyl / 94% dimethyl polysiloxane

TraceGOLD TG-1301MS GC columnsLow bleed, excellent reproducibility and column-to-column consistency even with sensitive detectors like ECD and MS

• Mid-polarity phase

• Long lifetime

• Excellent inertness

• Equivalent to USP G43 phase

Applications:• Alcohols• Volatile organics• Oxygenates• Residual solvents

Similar to: • Rtx-1301• DB-1301• BP-624• HP-1301• HP-624• SPB-1301• SPB-624• VP-1301• BF-624ms• CP-1301• CP-SelectTM 624 CB

TraceGOLD TG-1301MS GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 30 0.25 26091-1420 1 Each1.0 26091-2960 1 Each

60 0.25 26091-1540 1 Each1.0 26091-3080 1 Each

0.32 30 0.25 26091-1430 1 Each1.0 26091-2970 1 Each1.5 26091-3350 1 Each1.8 26091-3390 1 Each

60 1.8 26091-3410 1 Each

0.53 30 1.0 26091-2980 1 Each3.0 26091-3960 1 Each

60 3.0 26091-4080 1 Each

Learn more at thermofisher.com/GCcolumns

Page 53: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-044thermofisher.com/chromatographyconsumables

GC

columns and accessories

TraceGOLD TG-624 GC columnsOffers 90+% resolution of the first six gases in EPA Method 8260 and EPA Method 524.2 for volatile organics analysis

• Mid-polarity phase

• Ideal for EPA methods 624 and 608

• Allows resolution of 2-nitropropane from 1,1-dichloropropanone under EPA Method 524.2 revision IV

Applications:• Residual Solvents• Volatile Organic Compounds• Alcohols• Oxygenates

Similar to:

• DB-1301• DB-624• HP-1301• HP-624• SPB-1301• SPB-624• VF-1301• VF-624ms• CP-1301

• CP-Select 624 CB

• Rtx-624• BP-624• ZB-624•Optima-1301• Optima-624• AT-624• 007-1301

POLAR

6% cyanopropyl phenyl / 94% dimethyl polysiloxane

TraceGOLD TG-624 GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.18 20 1.0 26085-4950 1 Each40 1.0 26085-4960 1 Each

0.25 30 1.4 26085-3320 1 Each60 1.4 26085-3330 1 Each

0.32 30 1.8 26085-3390 1 Each60 1.8 26085-3410 1 Each

0.53 30 3.0 26085-3960 1 Each60 3.0 26085-4080 1 Each75 3.0 26085-4900 1 Each105 3.0 26085-4090 1 Each

TG-624 30m x 0.32mm x 1.80µmTemperature: 40°C (20 minute hold) to 240°C

at 10°C/min (20 minute hold)Detector Type: FIDCarrier Gas: HeFlow Rate: 2.15mL/minInjection Volume: 1mLInjection Mode: Headspace, Split (1:5), 140°C

1. 1,1-dichloroethane2. 1,1,1-trichloroethane3. carbon tetrachloride4. benzene5. 1,2-dichloroethane

1

24

5

3

10 12Minutes

4 6 8

Residual solvents class 1

Page 54: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-045

Applications:• Residual Solvents• Volatile Organic Compounds• Alcohols• Oxygenates

Similar to:• DB-624 Ultra Inert• VF-624ms• CP-Select 624 CB• ZB-624

TraceGOLD TG-624SilMS GC columns

ID (mm) Length (m)Film Thickness (µm) Cat. No. Quantity

0.18 20 1.0 26059-4950 1 Each0.25 30 1.4 26059-3320 1 Each

60 1.4 26059-3330 1 Each0.32 30 1.8 26059-3390 1 Each

60 1.8 26059-3410 1 Each0.53 30 3.0 26059-3960 1 Each

60 3.0 26059-4080 1 Each

TraceGOLD TG-624SilMS GC ColumnsHigh thermal stability column ideal for volatile organics analysis

• Mid-polarity phase

• High thermal stability – maximum temperatures up to 320°C

• Highly inert – excellent peak shape for a wide range of compounds

POLAR

320°C

6% cyanopropylphenyl / 94% dimethyl arylene polysiloxane

TG-624SilMS 30m x 0.32mm x 1.8μmTemperature: 40°C for 6 minutesDetector Type: MS (ISQ); m/z 40,41 for Acetonitrile (1), m/z 49, 84 for Dichloromethane (2)Carrier Gas: HeliumFlow Rate: 1.5 mL/minInjection Volume: 500µLInjection Mode: Headspace, Split (20:1) 220°C

1. Acetonitrile2. Dichloromethane

Minutes

0 1 2 3 4 5 6

0.00e0

5.00e6

1.00e7

1.50e7

2.00e7

2.50e7

3.00e7

3.50e7

4.00e7

4.50e7

5.00e7

1

2

Counts

R = 3.22

Acetonitrile and Dichloromethane

thermofisher.com/GCcolumns

Learn more at thermofisher.com/GCcolumns

Page 55: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-046thermofisher.com/chromatographyconsumables

GC

columns and accessories

TraceGOLD TG-1701MS GC columnsFeature a mix of cyano and phenyl groups for increased polarity and a different elution order relative to less polar columns

• Mid-polarity phase, 14% cyanopropylphenyl methylpolysiloxane

• Fully characterized for long-term reproducibility, column-to-column consistency and low bleed

• Optimal for confirmation analysis

• Equivalent to USP G46 phase

POLAR

14% cyanopropyl phenyl / 86% dimethyl polysiloxane

Applications:• Alcohols• Pesticides• Oxygenates• PCB cogeners• Aroclor mixes

Similar to:• Rtx-1701• DB-1701• HP-1701• SPB-1701• VF-1701• CP-SilTM 19 CB

TraceGOLD TG-1701MS GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 30 0.25 26090-1420 1 Each0.5 26090-2230 1 Each1.0 26090-2960 1 Each

60 0.25 26090-1540 1 Each1.0 26090-3080 1 Each

0.32 15 0.25 26090-1310 1 Each30 0.25 26090-1430 1 Each

0.5 26090-2240 1 Each1.0 26090-2970 1 Each

60 0.25 26090-1550 1 Each1.0 26090-3090 1 Each

0.53 30 0.25 26090-1440 1 Each1.0 26090-2980 1 Each3.0 26090-3960 1 Each

Page 56: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-047

TraceGOLD TG-17MS GC columnsParticularly suited to GC-MS applications that require more polarity than a 5% phenyl phase

• Mid-polarity phase

• Ideal for confirmational analysis

• Excellent inertness for active compounds such as pesticides

• Very low bleed ideal for analysis by GC-MS

POLAR

50% diphenyl / 50% dimethyl polysiloxane

Applications:• Pesticides and herbicides• Rosin acids• Phthalate esters• Triglycerides• Sterols

Similar to: • Rxi-17• DB-17• DB-608• VF-17ms• CP-Sil 24 CB

TraceGOLD TG-17MS GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 15 0.25 26089-1300 1 Each30 0.25 26089-1420 1 Each

0.5 26089-2230 1 Each1.0 26089-2960 1 Each

60 0.25 26089-1540 1 Each 0.32 30 0.25 26089-1430 1 Each

0.5 26089-2240 1 Each1.0 26089-2970 1 Each

0.53 30 0.25 26089-1440 1 Each1.0 26089-2980 1 Each1.5 26089-3360 1 Each

TG-17MS 30m x 0.25mm x 0.25µmTemperature: 90°C (1.0 minute hold) to 215°C (0.5 minute hold) at 25°C/minute to 235°C at 4°C/minute to 280°C/ minute at 15°C/minute to 320°C (20 minute hold) at 4°C/minuteDetector Type: MSCarrier Gas: HeFlow Rate: 1.2mL/minInjection Volume: 1.0µLInjection Mode: Splitless, 300°C

1. naphthalene 2. 1-methylnaphthalene 3. 2-methylnaphthalene 4. acenaphthylene 5. acenaphthene 6. fluorene 7. phenanthrene 8. anthracene 9. fluoranthene 10. pyrene 11. benzo(a)anthracene 12. chrysene 13. benzo(b)fluoranthene 14. benzo(k)fluoranthene

15. benzo(j)fluoranthene 16. benzo(a)pyrene 17. 3-methylcholanthrene 18. dibenzo(a,h)acridine19. dibenzo(a,j)acridine 20. indeno(1,2,3-cd)pyrene21. dibenzo(a,h)anthracene22. benzo(ghi)perylene 23. 7H-dibenzo(c,g)car-bazole24. dibenzo(a,e)pyrene 25. dibenzo(a,i)pyrene26. dibenzo(a,h)pyrene

1

2

3

4

56

789

10 1112

1314

15 1617

18

19

20,21

22

23

2425

26

4038363432302826242220181614121086Minutes

Polycyclic aromatic hydrocarbons

Learn more at thermofisher.com/GCcolumns

Page 57: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

GC

columns and accessories

TraceGOLD TG-17SilMS GC columnsExcellent separation of active environmental compounds

• Mid-polarity phase

• High thermal stability – maximum temperatures up to 340/360°C

• Excellent inertness for active environmental compounds such as PAHs

POLAR

340/360°C

G3

50% phenyl / 50% dimethyl arylene polysiloxane

Applications:• PAHs• Pesticides and herbicides• Phthalate esters• Triglycerides

Similar to:• DB-1 7ms• VF-17ms• CP-Sil 24 CB• ZB-50• BPX-50

TraceGOLD TG-17SilMS GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.15 10 0.15 26072-2750 1 Each0.18 20 0.18 26072-5780 1 Each0.25 30 0.25 26072-1420 1 Each0.32 30 0.25 26072-1430 1 Each

Learn more at thermofisher.com/GCcolumns

Page 58: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-049

TraceGOLD TG-225MS GC columnsOffers better thermal stability than comparable columns

• Polar phase

• Innovative deactivation process for siloxane reduces tailing and improves efficiency over comparable columns

• Equivalent to USP G7, G19 phasesPOLAR

50% cyanopropyl / 50% phenyl methyl polysiloxane

Applications:• FAMEs• Carbohydrates• Sterols• Flavor compounds

Similar to:• Rtx-225• DB-225• HP-225• SPB-225

TraceGOLD TG-225MS GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 30 0.25 26083-1420 1 Each60 0.25 26083-1540 1 Each

0.32 30 0.25 26083-1430 1 Each

12

34 5 6

7 8

12.5107.552.50Minutes

TG-225MS 15m x 0.25mm x 0.25µmTemperature: 190°C (5 minute hold) to 250°C at 8°C/min (5 minute hold)Detector Type: FIDCarrier Gas: HydrogenFlow Rate: 45cm/secInjection Volume: 0.5µLInjection Mode: Split (35:1), 260°C

1. rhamnitol2. fucitol3. ribitol4. arabinitol

5. mannitol6. galactitol7. glucitol8. inositol

Sugars

Learn more at thermofisher.com/GCcolumns

Page 59: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

GC

columns and accessories

TraceGOLD TG-200MS GC columnsExceptionally inert mid-polarity columns with selectivity and elution order optimized for difficult separations

• Polar phase,trifluoropropyl methylpolysiloxane solid phase resolves compounds that phenyl and cyano phases cannot

• Outstanding thermal stability and low bleed

• Suitable for use with sensitive detectors including ECD, NPD and MS

• Confirmation column in combination with another GC column

POLAR

Applications:• Solvents• Fluorocarbons• Alcohols and ketones• Silanes• Glycols

Similar to: • Rtx-200MS• DB-200• DB-210

TraceGOLD TG-200MS GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.15 20 0.15 26084-2760 1 Each0.25 30 0.25 26084-1420 1 Each

1.0 26084-2960 1 Each0.32 30 0.25 26084-1430 1 Each

0.5 26084-2240 1 Each1.0 26084-2970 1 Each

Page 60: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-051

TraceGOLD TG-WaxMS GC columnsManufactured for better column-to-column reproducibility

• Polar phase, polyethylene glycol

• Polar-deactivated surface tightly binds polymer for excellent thermal stability

• Resists oxidative damage, damage from strongly acidic or basic volatiles better than silicone solid phases

POLAR

Applications:• FAMEs• Flavor compounds

and essential oils• Solvents• Xylene isomers• EPA Method 603 for Acrolein/

Acrylonitrile

Similar to: • DB-WAX• DB-WAXetr• HP-Wax• HP-Innowax• Supelcowax 10• CP-Wax 52 CB• Stabilwax• Rtx-Wax• BP20• ZB-Wax• Optima Wax• AT-Wax

TraceGOLD TG-WaxMS GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.1 10 0.1 26088-0200 1 Each0.25 15 0.25 26088-1300 1 Each

30 0.25 26088-1420 1 Each0.5 26088-2230 1 Each

30 with 5m SafeGuard 0.25 26088-1421 1 Each60 0.25 26088-1540 1 Each

0.5 26088-2350 1 Each0.32 15 0.5 26088-2120 1 Each

30 0.25 26088-1430 1 Each0.5 26088-2240 1 Each1.0 26088-2970 1 Each

30m with 5m SafeGuard

0.25 26088-1435 1 Each

60 0.25 26088-1550 1 Each0.5 26088-2360 1 Each1.0 26088-3090 1 Each

0.53 15 0.5 26088-2130 1 Each1.0 26088-2860 1 Each

30 0.25 26088-1440 1 Each0.5 26088-2250 1 Each1.0 26088-2980 1 Each1.5 26088-3360 1 Each

60 0.25 26088-1560 1 Each0.5 26088-2370 1 Each1.0 26088-3100 1 Each

TraceGOLD TG-WaxMT Metal GC columns

ID (mm) Length (m)Film Thickness (µm) Cat. No. Quantity

0.25 30 0.25 26M88-1420 1 Each60 0.25 26M88-1540 1 Each

Learn more at thermofisher.com/GCcolumns

Page 61: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-052thermofisher.com/chromatographyconsumables

GC

columns and accessories

POLAR

240°C / 250°C

G25, G35

Modi�ed Polyethylene Glycol (PEG) for Acidic Compounds

TraceGOLD TG-WaxMS A GC columnsAcidic functionality in the polymer structure allows analysis of acidic compounds without derivatization

• Polar phase, acid-deactivated polyethylene glycol

• Resists oxidative damage and adsorption of acids

• Excellent peak shapes for high MW acids

• Equivalent to USP G25, G35 phases

Applications:• Organic acids• Free fatty acids• Alcohols

Similar to: • DB-FFAP• HP-FFAP• NUKOL• OV-351• CP-Wax 58 CB• FFAP• Stabilwax-DA• BP-21• Optima FFAP

TraceGOLD TG-WaxMS A GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 15 0.25 26087-1300 1 Each30 0.25 26087-1420 1 Each

0.5 26087-2230 1 Each60 0.25 26087-1540 1 Each

0.32 15 0.25 26087-1310 1 Each30 0.25 26087-1430 1 Each

0.5 26087-2240 1 Each1.0 26087-2970 1 Each

0.53 15 1.0 26087-2860 1 Each30 0.25 26087-1440 1 Each

1.0 26087-2980 1 Each

12 1684

Minutes

1

2

3

4

5

67

8

9

TG-WaxMS A 30m x 0.25mm x 0.25µmTemperature: 145°C Isothermal Detector Type: FIDCarrier Gas: HydrogenFlow Rate: 40cm/secInjection Volume: 1.0µLInjection Mode: Split (50:1), 250°C

1. acetic acid2. propionic acid3. isobutyric acid4. n-butyric acid5. isovaleric acid6. n-valeric acid

7. isocaproic acid8. caproic acid9. heptanoic acid

Free fatty acids

Page 62: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-053

TraceGOLD TG-WaxMS B GC columns Base deactivation allows analysis of basic analytes without derivatization or column priming

• Polar phase, base deactivated polyethylene glycol

• Reduced absorption and improved responsiveness for basic compounds

• Not suitable for use with water or alcohols

POLAR

Applications:• Amines• Alkylamines• Diamines• Other basic compounds

Similar to: • CAM• CarbowaxTM Amine• CP Wax51• Stabilwax-DB

TraceGOLD TG-WaxMS B GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 30 0.25 26086-1420 1 Each0.5 26086-2230 1 Each

0.32 30 0.25 26086-1430 1 Each0.53 30 1.0 26086-2980 1 Each

TG-WaxMS B 30m x 0.53mm x 1.0µmTemperature: 45°C IsothermalDetector Type: FIDCarrier Gas: HydrogenFlow Rate: 40cm/secInjection Volume: 1µLInjection Mode: Direct Injection, 250°C

1. trimethylamine2. dimethylamine3. ethylamine4. methylamine5. isopropylamine6. n-propylamine

7. tert-butylamine8. diethylamine9. sec-butylamine

1

2

3

4

5

6

78 9

3 4210Minutes

Amines

Learn more at thermofisher.com/GCcolumns

Page 63: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-054thermofisher.com/chromatographyconsumables

GC

columns and accessories

TraceGOLD TG-POLAR GC columnsSpecifically designed polymer and surface treatment overcome traditional problems with high-polarity columns

• Highly polar phase

• Strong dipole moment and high selectivity for cis/trans compounds or compounds with conjugated double bonds

• Equivalent to USP G8 and G48

POLAR

90% biscyanopropyl / 10% cyanopropyl phenyl polysiloxane

Applications:• Cis/Trans FAMEs• Dioxins

Similar to: • DB-23• HP-23• Rtx-2330• SP-2330• SP-2380• SPB-2560• HP-88

• Silar 10c• CP-Sil 88

FAME• CP-Sil 88• BPX 70• BPX 90

TraceGOLD TG-POLAR GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 30 0.1 26082-0470 1 Each0.2 26082-5010 1 Each

60 0.1 26082-0590 1 Each0.2 26082-5020 1 Each

105 0.1 26082-5000 1 Each0.2 26082-5030 1 Each

0.32 30 0.2 26082-5040 1 Each60 0.2 26082-5050 1 Each

2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5Minutes

10

20

30

40

50

60

70

80

90

100

1

23

4

5

6

7

89

10

11

12

13

14Rela

tive

Abun

danc

e

TG-POLAR 30m x 0.25mm x 0.2µmTemperature: 100°C (0.5 minute hold) to 195°C at 25°C/minute (1 minute hold) to 250°C at 10°C/minute (3 minute hold)Detector Type: MSCarrier Gas: HeFlow Rate: 1.2mL/minInjection Volume: 0.1µLInjection Mode: Split (100:1), 250°C

1. Methyl octanoate2. Methyl decanoate3. Methyl decanoate4. Methyl myristate5. Methyl palmitate6. Methyl palmitoleate7. Methyl stearate8. Methyl oleate9. Methyl linoleate

10. Methyl linolenate11. Methyl arachidate12. Methyl behenate13. Methyl cis-13-

docosenoate14. Methyl tetracosanoate

FAMEs C8-C24

Page 64: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-055

TraceGOLD TG-XLBMS GC columnsGeneral purpose columns exhibiting extremely low bleed

• Low polarity phase, proprietary

• Low bleed for excellent signal-to-noise ratio, sensitivity and mass spectral integrity

• Ideal for analysis of active, high molecular weight compounds with sensitive GC-MS systems

TraceGOLD TG-XLBMS GC columns

ID (mm) Length (m)Film Thickness (µm) Cat. No. Quantity

0.18 20 0.18 26079-5780 1 Each

0.2515 0.25 26079-1300 1 Each30 0.25 26079-1420 1 Each

0.5 26079-2230 1 Each60 0.25 26079-1540 1 Each

0.32 30 0.25 26079-1430 1 Each

Semi-Volatile organic compounds (SVOC) application kit

Description Cat. No Quantity

Semi-Volatile Organic Compounds (SVOC) Application kit 60181-736 1 Each

Contains the following:TG-5MS GC COLUMN 30MX0.25MMX 0.50MM 26098-2230 1 EachBTO Septa 11mm Diameter (Blister Pack) 31303233-BP 50 PackLINERGOLD PRECISION LINER, WOOL, 4X6.3X78.5MM 5PK 453A1255-UI 5 Pack

LinerGOLD Splitless Liner, Single Taper, Wool 4x6.5x78.5mm 453A1925-UI 5 Pack

Gold Plated Inlet Seals, 0.8mm 290GA082 2 PackLiner Sealing Ring for SSL / 5pk 29001320 5 PackColumn Nut for SSL & SSLBackflush 35050458 5 Pack15/85 GRAPH/VESP Ferrule for 0.1-0.25mmID column 290VA191 10 Pack

SILANIZED AMB TARGET DP-IDVIAL, 100/PK c4000-s2w 100 PackAVCS BLUE CAP&TS SEPTA100/PK,1000/CS c5000-54b 100 Pack10UL FN SYRINGE, 50MM LENGTH23 GAUGE, CONE 1/PK 36520060 1 Each

Applications• Pesticides• PCB congeners • PAHs• Aroclor mixes

Similar to:• Rxi-XLB• DB-XLB• VF-Xms

POLAR

Proprietary

340°C/360°C

N/A

thermofisher.com/GCcolumns

Learn more at thermofisher.com/GCcolumns

Page 65: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

GC

columns and accessories

TraceGOLD TG-VRX GC columnsApplication specific column for volatile organic pollutants

• Highly stable polymer phase

• Low bleed for excellent signal-to-noise ratio, sensitivity and mass spectral integrity

• Excellent resolution for analysis of volatile compounds

• Fast analysis times for volatile compounds

Applications:• Volatile organic pollutants• US EPA Method 8021

compounds

Similar to:• Rtx-VRX• DB-VRX

TraceGOLD TG-VRX GC columns

ID (mm) Length (m)Film Thickness (µm) Cat. No. Quantity

0.18 20 1.0 26081-4950 1 Each40 1.0 26081-4960 1 Each

0.25 30 1.4 26081-3320 1 Each60 1.4 26081-3330 1 Each

0.32 30 1.8 26081-3390 1 Each60 1.8 26081-3410 1 Each

POLAR

Proprietary

260°C

N/A

Page 66: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-057

TraceGOLD TG-VMS GC columnsApplication specific column for volatile organic pollutants

• Highly stable polymer phase

• Low bleed for excellent signal-to-noise ratio, sensitivity and mass spectral integrity

• Excellent resolution for analysis of volatile compounds

• Fast analysis times for volatile compounds

Applications:• Volatile organic pollutants • US EPA Method 8260B

compounds

Similar to:• Rtx-VMS

TraceGOLD TG-VMS GC columns

ID (mm) Length (m)Film Thickness (µm) Cat. No. Quantity

0.18 20 1.0 26080-4950 1 Each0.25 30 1.4 26080-3320 1 Each

60 1.4 26080-3330 1 Each 0.32 60 1.8 26080-3410 1 Each

Volatile organic compound (VOC) application kit

Description Cat. No. Quantity

Volatile Organic Compound(VOC) Apps Kit 60181-734 1 EachContains the following:TG-VMS GC Column,20mx0.18mmx 1.00μm 26080-4950 1 EachBTO Septa 11mm Diameter (Blister Pack) 31303233-BP 50 PackLinerGOLD Split Liner 1x6.3x78.5mm 453A1335-UI 5 PackLinerGOLD Splitless Liner, Single Taper, Wool 4x6.5x78.5mm 453A1925-UI 5 Pack

Gold Plated Inlet Seals, 0.8mm 290GA082 2 PackLiner Sealing Ring for SSL 29001320 5 PackColumn Nut for SSL & SSLBackflush 35050458 5 Pack15/85 GRAPH/VESP Ferrule for 0.1-0.25mmID column 290VA191 10 PackSILANIZED AMB TARGET DP-IDVIAL, c4000-s2w 100 PackAVCS BLUE CAP&TS SEPTA c5000-54b 100 PackCLR 40ML EPA ASM VIAL KIT,1000 CLASS, B7950 100 Pack

POLAR

Proprietary

260°C

N/A

thermofisher.com/GCcolumns

Learn more at thermofisher.com/GCcolumns

Page 67: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-058thermofisher.com/chromatographyconsumables

GC

columns and accessories

TraceGOLD TG-OCP I / TG-OCP II GC columnsApplication-specific columns for organochlorine pesticides and herbicides

• Low bleed for excellent signal-to-noise ratio, sensitivity and mass spectral integrity

• Fast analysis time giving full separation of chlorinated pesticides

• Ideal for US EPA methods 8081, 608 and CLP

Applications:• Organochlorine pesticides• Herbicides

Similar to: • Rtx-CLPesticides/

Rtx-CLPesticides2

TraceGOLD TG-OCP I GC columns

ID (mm) Length (m)Film Thickness (µm) Cat. No. Quantity

0.25 30 0.25 26078-1420 1 Each0.32 30 0.32 26078-5760 1 Each

TraceGOLD TG-OCP II GC columns

ID (mm) Length (m)Film Thickness (µm) Cat. No. Quantity

0.18 20 0.14 26077-5690 1 Each0.25 30 0.2 26077-5720 1 Each0.32 30 0.25 26077-1430 1 Each

POLAR

Proprietary

340°C

N/A

Page 68: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

TraceGOLD TG-OPP I / TG-OPP II GC columnsApplication-specific columns for organophosphorus pesticides

• Low bleed for excellent signal-to-noise ratio, sensitivity and mass spectral integrity

• Fast analysis time giving full separation of organophosphorus pesticides

• Ideal for US EPA methods 8141A

Applications:• Organophosphorus pesticides

Similar to: • Rtx-OPPesticides/

Rtx-OPPesticides2

TraceGOLD TG-OPP I GC columns

ID (mm) Length (m)Film Thickness (µm) Cat. No. Quantity

0.25 30 0.25 26076-1420 1 Each0.32 30 0.5 26076-2240 1 Each

TraceGOLD TG-OPP II GC columns

ID (mm) Length (m)Film Thickness (µm) Cat. No. Quantity

0.25 30 0.25 26075-1420 1 Each0.32 30 0.32 26075-5760 1 Each0.53 30 0.5 26075-2250 1 Each

POLAR

Proprietary

330°C

N/A

Learn more at thermofisher.com/GCcolumns

Page 69: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

GC

Colum

ns and accessories

thermofisher.com/chromatographyconsumables

TraceGOLD TG-ALC Plus I / TG-ALC Plus II GC columnsApplication-specific columns for blood alcohol analysis

• Low bleed for excellent signal-to-noise ratio, sensitivity and mass spectral integrity

• Fast analysis time giving full separation of blood alcohols

Applications:• Blood alcohol analysis• Abused inhalent anesthetics• γ-hydroxybutyrate (GHB)• γ-butyrolactone (GBL)• Glycols• Common industrial solvents

Similar to: • Rtx BAC Plus 1 / Rtx BAC Plus 2

TraceGOLD TG-ALC Plus I GC columns

ID (mm) Length (m)Film Thickness (µm) Cat. No. Quantity

0.32 30 1.8 26063-3390 1 Each0.53 30 3.0 26063-3960 1 Each

TraceGOLD TG-ALC Plus II GC columns

ID (mm) Length (m)Film Thickness (µm) Cat. No. Quantity

0.32 30 0.5 26063-2240 1 Each0.53 30 1.0 26063-2980 1 Each

POLAR

Proprietary

260°C

N/A

5-060

Page 70: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-061

TraceGOLD TG-Dioxin GC columnsExcellent separation of toxic dioxin and furan congeners

• Isomer specificity for 2,3,7,8-TCDD and 2,3,7,8-TCDF achieved with a single GC column

• High thermal stability – maximum temperatures up to 340°C

• Unique selectivity for toxic dioxin and furan congeners allows use as a confirmation GC column

TraceGOLD TG-Dioxin GC columns

ID (mm) Length (m)Film Thickness (µm) Cat. No. Quantity

0.18 40 0.18 26066-4800 1 Each0.25 60 0.25 26066-1540 1 Each

Applications:• Dioxins• Furans

Similar to: • Rtx-Dioxin2• DB-Dioxin

POLAR

Proprietary

340°C

N/A

Persistent organic pollutants (POPs) confirmation kit

Description Cat. No Quantity

Persistent Organic Pollutants (POPs) Confirmation kit TS-MKITG503 1 EachContains the following: TG-Dioxin GC Column 60m x0.25mmx0.25μm 26066-1540 1 EachBTO Septa 11mm Diameter (Blister Pack) 31303233-BP 50 PackLINERGOLD PRECISION LINER, WOOL, 4X6.3X78.5MM 5PK 453A1255-UI 5 Pack

LinerGOLD Splitless Liner, Single Taper, Wool 4x6.5x78.5mm 453A1925-UI 5 Pack

GOLD PLATED INLET SEALS, FORAGILENT GC’S, 0.8MM, 2PK 290GA082 2 Pack

Liner Sealing Ring for SSL 29001320 5 PackColumn Nut for SSL & SSLBackflush 35050458 5 Pack15/85 GRAPH/VESP Ferrule for 0.1-0.25mmID column 290VA191 10 Pack1.1ML SCREW VIAL 500/PK CLR TAPERED 12x32MM 1.1-STVG 500 Pack8mm SCREW CAP 500/PK PREFI WITH SILICONE/TEFLON LINER 8-SC-ST15 500 Pack

10UL FN SYRINGE, 57MM LENGTH23S GAUGE, CONE 1/PK 365D0271 1 Each

Learn more at thermofisher.com/GCcolumns

Page 71: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-062thermofisher.com/chromatographyconsumables

GC

columns and accessories

TRACE TR-1 GC columnsDesigned for method development

• Non-polar phase, 100% dimethyl polysiloxane

• High operating temperature

TRACE TR-1MS GC columnsExtremely low-bleed non-polar columns suitable for GC-MS applications

• Non-polar phase, 100% dimethyl polysiloxane

• High operating temperature

• Inert phase suited for environmental analyses

Polysiloxane

POLAR

340ºC/360ºC

Polysiloxane

POLAR

Applications:• Chlorinated and nitroaromatic

compounds• Environmental analyses

TRACE TR-1 GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 15 0.25 260A130P 1 Each30 0.1 260A047P 1 Each

0.25 260A142P 1 Each60 0.25 260A154P 1 Each

0.32 15 0.25 260A131P 1 Each30 0.25 260A143P 1 Each

Applications:• Chlorinated and nitroaromatic

compounds• GC-MS environmental analyses

TRACE TR-1MS GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 30 0.1 260B047P 1 Each0.25 260B142P 1 Each

60 0.25 260B154P 1 Each0.32 30 0.25 260B143P 1 Each

60 0.25 260B155P 1 Each1.0 260B309P 1 Each

TRACE GC columns

Page 72: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-063

TRACE TR-5 GC columnsExcellent starting columns for method development, capable of performing most required separations

• Non-polar phase, 5% phenyl methyl polysiloxane

• High operating temperature and extremely low bleed

• Widely used in a variety of applicationsPOLAR

Applications:• Alcohols• Free fatty acids• Aromatics• Flavors• Low polarity pesticides

TRACE TR-5 GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 15 0.25 260E130P 1 Each30 0.25 260E142P 1 Each

0.5 260E223P 1 Each60 0.25 260E154P 1 Each

0.32 7 0.25 260E113P 1 Each15 0.25 260E131P 1 Each30 0.25 260E143P 1 Each

0.5 260E224P 1 Each1.0 260E297P 1 Each

60 0.25 260E155P 1 Each100 0.5 260E242P 1 Each

0.53 30 0.5 260E225P 1 Each1.0 260E298P 1 Each1.5 260E336P 1 Each5.0 260E470P 1 Each

TRACE TR-5HT GC columnsFeature upper temperature limits as high as 400°C

• Non-polar phase, 5% phenyl polycarborane siloxane

• Allow the elution of higher-boiling hydrocarbons up to C100

• Low bleed even at elevated temperatures POLAR

Applications:• Hydrocarbons• Solvents• Pesticides• Herbicides• Phenols• Amines

TRACE TR-5HT GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 15 0.1 260H035P 1 Each30 0.1 260H047P 1 Each

0.25 260H142P 1 Each0.32 12 0.1 260H030P 1 Each

Learn more at thermofisher.com/GCcolumns

Page 73: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-064thermofisher.com/chromatographyconsumables

GC

columns and accessories

TRACE TR-5MS GC columnsFeatures a popular GC-MS phase for many applications

• Non-polar phase, 5% phenyl polysilphenylene-siloxane

• Low bleed and high stability

• High signal-to-noise ratio for increased sensitivity

• High robustness to oxygen and water contaminationPOLAR

Applications:• Hydrocarbons• Solvents• Pesticides• Herbicides• Phenols• Amines

TRACE TR-5MS GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.10 10 0.1 260F020P 1 Each0.18 20 0.18 260F578P 1 Each0.25 15 0.1 260F035P 1 Each

0.25 260F130P 1 Each30 0.1 260F047P 1 Each

0.25 260F142P 1 Each0.25 260F142J 1 Each0.5 260F223P 1 Each1.0 260F296P 1 Each

60 0.25 260F154P 1 Each1.0 260F308P 1 Each

0.32 15 1.0 260F285P 1 Each30 0.25 260F143P 1 Each

0.5 260F224P 1 Each1.0 260F297P 1 Each

0.53 30 0.5 260F225P 1 Each1.0 260F298P 1 Each1.5 260F336P 1 Each3.0 260F396P 1 Each

Page 74: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-065

GC

Colum

ns and Accessories >

> TR

AC

E G

C C

olumns

TRACE TR-35MS GC columnsMid-polarity columns excellent for many applications

• Mid-polarity phase, 35% phenyl polysilphenylene-siloxane

• Exceptionally low surface activity

• Low bleed even at elevated temperatures POLAR

Applications:• Pesticides• Herbicides• Drugs of abuse• PAHs• Pharmaceuticals

TRACE TR-35MS GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 15 0.25 260C130P 1 Each30 0.25 260C142P 1 Each60 0.25 260C154P 1 Each

0.32 30 0.25 260C143P 1 Each0.53 15 1.0 260C286P 1 Each

30 1.0 260C298P 1 Each

TRACE TR-1701 GC columnsMid-polarity column with alternative selectivity

• Mid-polarity phase, 14% cyanopropylphenyl polysiloxane

• Low bleed even at a high operating temperature

• Excellent starting point for method development

• Suitable for a wide variety of applicationsPOLAR

Applications:• Pesticides• PCBs• PAHs• Organic acids• Drugs• Steroids• EPA 608, 8081

TRACE TR-1701 GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 30 0.25 260Q142P 1 Each60 0.25 260Q154P 1 Each

0.32 15 0.25 260Q131P 1 Each30 0.25 260Q143P 1 Each60 1.0 260Q309P 1 Each

0.25 260Q155P 1 Each0.53 30 1.0 260Q298P 1 Each

Learn more at thermofisher/GCcolumns

Page 75: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-066thermofisher.com/chromatographyconsumables

GC

Colum

ns and Accessories >

> TR

AC

E G

C C

olumns

GC

columns and accessories

TRACE TR-50MS GC columnsMid-polarity columns well-suited to GC-MS applications

• Mid-polarity phase, 50% phenyl polysilphenylene-siloxane

• Low bleed decreases MS contamination

• Particularly useful for applications requiring a higher temperature and more polarity than a 5% phenyl column

• Column inertness results in minimal peak tailing and decreased breakdown of sensitive samples

POLAR

Applications:• Herbicides• Drugs of abuse• EPA 604, 608, 8060, 8081• Pharmaceuticals

TRACE TR-50MS GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 30 0.25 260R142P 1 Each0.32 30 0.25 260R143P 1 Each

TRACE TR-225 GC columnsReliable and reproducible performance

• Mid-polarity phase, 50% cyanopropylphenyl polysiloxane

• Low bleed even at elevated temperatures

• Outstanding robustness for difficult separations

• Manufactured to minimize risk of damage from contaminated carrier gas

POLAR

230°C / 250°C

Applications:• Fatty Acid Methyl Esters

(FAMEs)• Carbohydrates• Neutral sterols

TRACE TR-225 GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 30 0.25 260Y142P 1 Each

Page 76: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-067

TRACE TR-Wax GC columnsGeneral purpose, high-polarity columns

• Polar phase, polyethylene glycol

• Highly crosslinked and fully deactivated

• Solvent washable POLAR

Applications:• Esters• Alcohols• Ketones• Glycols• Aromatic isomers

TRACE TR-Wax GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 30 0.25 260W142P 1 Each0.5 260W223P 1 Each1.0 260W296P 1 Each

60 0.25 260W154P 1 Each0.32 15 0.25 260W131P 1 Each

30 0.25 260W143P 1 Each0.5 260W224P 1 Each1.0 260W297P 1 Each

60 0.25 260W155P 1 Each1.0 260W309P 1 Each

0.53 15 1.0 260W286P 1 Each30 0.5 260W225P 1 Each

1.0 260W298P 1 Each60 1.0 260W310P 1 Each

TRACE TR-WaxMS GC columnsFeature a high-polarity phase designed for mass spectrometry detectors

• Polar phase, polyethylene glycol

• Proprietary bonding method expands operating temperatures

• Extremely low bleed improves sensitivity and library matches

• High stability with oxygen and water

POLAR

Applications:• Aromatic hydrocarbons• Food additives• Essential oils• Alcohols• Esters• Aldehydes• Ketones

TRACE TR-WaxMS GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 30 0.25 260X142P 1 Each0.5 260X223P 1 Each1.0 260X296P 1 Each

60 0.25 260X154P 1 Each0.32 30 0.25 260X143P 1 Each

0.5 260X224P 1 Each60 0.25 260X155P 1 Each

Learn more at thermofisher.com/GCcolumns

Page 77: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-068thermofisher.com/chromatographyconsumables

GC

columns and accessories

TRACE TR-FFAP GC columnsHigh-polarity phase optimized for FFAP analysis

• Polar phase, TPA modified polyethylene glycol

• Bonded FFAP phase

• Quality tested for acidic compound analysis POLAR

TRACE TR-FFAP GC Columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.25 15 0.25 260N130P 1 Each30 0.25 260N142P 1 Each60 0.25 260N154P 1 Each

0.32 30 0.25 260N143P 1 Each50 0.5 260N230P 1 Each

0.53 30 0.5 260N225P 1 Each1.0 260N298P 1 Each

TRACE TR-V1 GC columnsMid-polarity, thick-film columns

• Mid-polarity phase, 6% cyanopropylphenyl polysiloxane

• Thick films for the analysis of volatile analytes

• Low bleed suitable for MS detection POLAR

Applications:• Volatile organics• Alcohols• EPA 502.2, 608 and 624

TRACE TR-V1 GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.18 20 1.0 260V495P 1 Each0.25 30 1.4 260V332P 1 Each

60 1.4 260V333P 1 Each0.32 30 1.8 260V339P 1 Each

60 1.8 260V341P 1 Each0.53 30 3.0 260V396P 1 Each

Applications:• FFAP analysis• Acidic compound analysis

Page 78: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-069

TRACE TR-FAME GC columnsHigh-polarity phase optimized for FAME analysis

• Polar phase, 70% cyanopropyl polysilphenylene-siloxane

• High operating temperature compared to competitor columns

• Low bleed for mass spectrometry use POLAR

Applications:• Fatty Acid Methyl Esters

(FAMEs)• FAMEs Cis/Trans Isomers

TRACE TR-FAME GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.10 10 0.2 260M096P 1 Each0.22 25 0.25 260M135P 1 Each

30 0.25 260M141P 1 Each50 0.25 260M147P 1 Each60 0.25 260M153P 1 Each

0.25 30 0.25 260M142P 1 Each60 0.25 260M154P 1 Each100 0.20 260M154P 1 Each100 0.20 260M238P120 0.25 260M166L 1 Each

0.32 25 0.25 260M137P 1 Each30 0.25 260M143P 1 Each60 0.25 260M155P 1 Each

Learn more at thermofisher.com/GCcolumns

Page 79: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-070thermofisher.com/chromatographyconsumables

GC

columns and accessories

TRACE GC columns for EPA methodsLow bleed and temperature-stable performance tailored to specific EPA methodologies

• TRACE TR-524 and TRACE TR-525 Columns: US EPA Drinking Water Test Methods 524 or 525

• TRACE TR-527 Columns: US EPA Drinking Water Test Method 527, features the robust, low-bleed performance required for analysis of pesticides and flame retardants

• TRACE TR-8270 Columns: US EPA Solid Waste Test Method 8270

• TRACE TR-8095 Columns: US EPA Method 8095 for Explosives Testing featuring high max temperature and low surface activity

Applications:• Volatile Organic Compounds

(VOCs)• Pesticides• Flame retardants• Explosives

TRACE GC columns for EPA methods

Phase ID (mm)Length (m)

Film Thickness (μm) Cat. No. Quantity

TR-524 0.18 20 1.0 26RV495P 1 EachTR-525 0.25 30 0.25 26RX142P 1 EachTR-8095 0.32 12 0.25 260P123P 1 EachTR-8270 0.25 30 0.5 26RF223P 1 Each

TRACE GC columns for pesticidesSpecifically designed and tested for analysis of pesticides

• Low bleed decreases MS contamination

• Particularly useful for applications requiring a higher temperature

• Column inertness results in minimal peak tailing and decreased breakdown of sensitive samples

Applications:• Organophosphate pesticides• Organochlorine pesticides• Pyrethroid pesticides• Herbicides

TRACE GC columns for pesticides

Phase ID (mm)Length (m)

Film Thickness (μm) Guard Cat. No. Quantity

TR-Pesticide 0.25 30 0.25 5m guard column attached 26RF142F 1 Each

TR-Pesticide II 0.25 30 0.25 5m guard column attached 26RD142F 1 Each

TR-Pesticide III 0.25 30 0.25 5m guard column attached 26RC142F 1 Each

TR-Pesticide IV 0.25 30 0.25 – 26RC142P 1 Each

Page 80: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-071

TRACE GC columns for dioxin and PCB analysisDesigned to meet the requirements of high resolution GC-MS methods

• TRACE TR-Dioxin 5MS Columns; Specifically designed for Dioxin and Furan testing

• Wide coverage of the 17 cogeners with the highest toxicological significance

• TRACE TR-PCB 8MS Columns; meets the requirements for HR GC-MS analysis of PCBs

• Low bleed

TRACE GC Columns for dioxin and PCB analysis

Phase ID (mm) Length (m)

Film Thickness (μm) Cat. No. Quantity

TR-PCB 8MS 0.25 50 0.25 26AJ148P 1 Each

TR-Dioxin 5MS 0.25 60 0.25 26AF154P 1 Each

TR-Dioxin 5MS 0.25 30 0.1 26AF047P 1 Each

TR-Dioxin 5MS 0.25 60 0.1 26AF059P 1 Each

Applications:• Dioxins (PCDDs)• Furans (PCDFs)• PCB congeners

TRACE GC columns for biodiesel analysisDesigned for use in carbon neutral fuels development applications

• GC columns designed for specific EN methods and ASTM methods

• Specific columns for the determination of methanol, FAMEs or glycerides

Applications:• Biodiesel• ASTM D-6584• EN14214

TRACE GC Columns for biodiesel analysis

Phase Method ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

TR-BioDiesel (M) EN 14110 0.32 30 3.0 26AA395P 1 EachTR-BioDiesel (G) EN 14105 0.32 10 0.1 26AF024P 1 EachTR-BioDiesel (F) EN 14103 0.25 30 0.25 26AX142P 1 EachTR-BioDiesel (G) ASTM ASTM D-6584 0.32 10 0.1 26RF024P 1 Each

TRACE GC columns for drugs of abuseSpecifically designed for the analysis of common drugs of abuse

• TRACE TR-DoA 5MS Columns; widely used for the analysis and determination of a range of toxicological target compounds including amphetamines, codeine and morphine

• TRACE TR-DoA 35MS Columns; the recommended column for use in drug testing labs for the confirmation of THC

Applications:• Amphetamines, codeine

and morphine

TRACE GC columns for drugs of abuse

Phase ID (mm)Length (m)

Film Thickness (μm) Cat. No. Quantity

TR-DoA35 0.20 15 0.33 26AC497P 1 EachTR-DoA5 0.25 15 0.25 26AF130P 1 Each

Learn more at thermofisher.com/GCcolumns

Page 81: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-072thermofisher.com/chromatographyconsumables

GC

columns and accessories

UltraFast GC columns The huge demand of samples to be analyzed every day by labs in industries such as environmental and petrochemical requires an increased speed of analysis

A significant gain in analysis speed compared to conventional GC procedures is obtained through UltraFast Gas Chromatography. UltraFast GC utilizes short (2-10m) narrow bore capillaries and temperature programming conditions usually faster than 2°C/s. This leads to peak widths in the 50-200ms range. The analysis times are in the range of 1 minute or even less.

Benefits of Thermo Scientific™ UltraFast™ GC columns• Dramatically shorter analysis times – typically a minute

or less• Ideal for applications in petrochemical and environmental

markets• Long column lifetimes

Application – UltraFast Analysis of Pure Petroleum Products through Nanovolumes InjectionThe analyses were performed in the UltraFast GC mode using a TRACE GC Ultra System equipped with a Split/Splitless injector (SSL) and a Digital Pressure and Flow Controller, as well as a FAST FID detector. The GC System was also equipped with an UltraFast Module (UFM).

Split injections were performed with a AS3000 Autosampler using a 0.5µL plunger-in-needle syringe p/n 36504045. A minimum penetration depth in the injector (cold needle mode) was set, and 0.3µL of air was automatically withdrawn after the sample to ensure that the part of the needle inserted into the injector was empty. A 3mm ID upper-tapered empty liner with an 8mm long and 1mm wide restriction at the top was installed. The SSL injector was set to 225°C and the FID to 320°C.

0

12

3

4

5

67 8

1

2

3

4

5

6

7

8

9

11

10 12

13

14

15

16

1718

19

20

1615

14

13

1210

11

9

17 18 19

16 32 48 64 80

0 16 32 48 64 80

Seconds

Seconds

20 nl

20 nl

UFC-1 10m x 0.32mm x 3umTemperature: 40°C (6 sec hold) to 300°C

(6 sec hold) at 180°C/minDetector Type: FIDCarrier Gas: HeliumFlow Rate: 0.5mL/minInjection Mode: Split/Splitless

1. propane2. methyl-propane3. butane4. methyl-butane5. pentane6. methyl-pentane7. hexane8. dimethyl-pentane9. heptane10. toluene

11. octane12. p-xylene13. propyl-benzene14. n-decane15. butyl-benzene16. n-dodecane17. n-tridecane18. n-tetradecane19. n-pentadecane

1. methyl-propane2. butane3. 2-methyl-butane4. pentane5. ter-butyl alcohol6. methyl-pentane7. 3-methyl-pentane8. hexane9. dimethyl-pentane10. cyclohexane11. dimethyl-hexane

12. toluene13. ethyl-benzene14. p-xylene15. m-xylene16. propyl-benzene17. tetramethyl-octane18. 1,2,4-trimethyl-benzene19. tri/tetramethyl-

benzene isomers20. naphthalene

Page 82: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-073

UltraFast GC columnsShort, narrow-bore columns for use with the Thermo Scientific TRACE GC UltraFast instrument

• Dramatically shorter analysis times

• Increase sample throughput by a factor of 20

• Lengthen column lifetimes

Applications:• Chemical• Petrochemical• Environmental• Flavors and fragrances

UltraFast GC columns

Phase ID (mm)Length (m)

Film Thickness (µm) Uses Cat. No. Quantity

UFC-1 0.10 5 0.1 General UFMC00001010401 1 Each0.32 5 0.25 ISO 9377-2 UFMC00001070404 1 Each

UFC-5 0.10 5 0.4 General UFMC00200000000 1 Each5 0.1 General UFMC00300000000 1 Each10 0.4 General UFMC00502010006 1 Each

UFC-WAX 0.10 5 0.1 FAMES, Essential Oils UFMC00001010501 1 Each5 0.2 General UFMC00001010503 1 Each

UFC-264 0.10 10 0.5 Volatiles UFMC00002010207 1 EachUFC-M1 0.32 5 0.25 General UFMC00001070904 1 Each

Learn more at thermofisher.com/GCcolumns

Page 83: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-074thermofisher.com/chromatographyconsumables

GC

columns and accessories

Thermo Scientific™ TracePLOT™ TG-BOND Alumina GC columns: Na2SO4 and KCl deactivationOptimized for linear and quantitative analysis of polar unsaturated hydrocarbons

• Strong bonding to prevent particle generation suits these columns in valve-switching operations without damage to injection and detection systems from particle release

• Columns to which water has adsorbed may be regenerated to restore full efficiency and selectivity

• Each column has been tested to ensure proper film thickness (1,3-butadiene), selectivity (propadiene and methyl acetylene), resolution (trans-2-butene and 1-butene) and coating efficiency (1,3-butadiene)

Applications:• C1-C5 hydrocarbons• Unsaturated hydrocarbon

isomers

TracePLOT TG-BOND Alumina GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

Na2SO4 Deactivation0.32 30 5 26001-6020 1 Each

50 5 26001-6050 1 Each0.53 30 10 26001-6080 1 Each

50 10 26001-6110 1 EachKCl Deactivation0.32 30 5 26002-6020 1 Each

50 5 26002-6050 1 Each0.53 30 10 26002-6080 1 Each

50 10 26002-6110 1 Each

TracePLOT TG-BOND Sieve 5A GC columnsDesigned for separation of Ar/O2 and other permanent gases

• Specially designed coating and deactivation procedures for chromatographic efficiency and the integrity of the coating porous layer

• Deactivation process yields a sharp peak for CO elution rather than the tailing commonly seen in other columns

• High retention of molecular sieve permits separation of permanent gases at temperatures above ambient

• Uniform particles remain adherent to the tubing even following continuous valve-cycling

Applications:• Permanent gases• Refinery or natural gases

TracePLOT TG-BOND Sieve 5A GC Columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.32 15 30 26003-6010 1 Each30 30 26003-6040 1 Each

0.53 15 50 26003-6070 1 Each30 50 26003-6100 1 Each50 50 26003-1630 1 Each

TracePLOT GC columns

Page 84: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-075

TracePLOT TG-BOND Q GC ColumnsNon-polar columns for oxygenated compounds and solvents

• Non-polar 100q% divinyl benzene phase

• Particles incorporated into the walls of the tubing for essentially no particle release

TracePLOT TG-BOND Q+ GC columnsIntermediate polarity columns for baseline separation of ethane, ethylene and acetylene

• Intermediate polarity, porous divinyl benzene homopolymer

• Particles incorporated into the walls of the tubing for essentially no particle release

Applications:• C1 to C3 isomers and alkanes

up to C12• Separation of CO2, methane

and O2/N2/CO• Analysis of oxygenated

compounds and solvents

TracePLOT TG-BOND Q GC columns

ID (mm) Length (m) Film Thickness (μm) Cat. No. Quantity

0.32 15 10 26004-6000 1 Each30 10 26004-6030 1 Each

0.53 15 20 26004-6060 1 Each30 20 26004-6090 1 Each

Applications:• Separation of ethane, ethylene

and acetylene to baseline

TracePLOT TG-BOND Q+ GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.32 15 10 26005-6000 1 Each

30 10 26005-6030 1 Each

0.53 15 20 26005-6060 1 Each30 20 26005-6090 1 Each

Learn more at thermofisher.com/GCcolumns

Page 85: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-076thermofisher.com/chromatographyconsumables

GC

columns and accessories

TracePLOT TG-BOND S GC columnsColumns for analysis of non-polar and mid-polar compounds

• Mid-polarity, divinylbenzene 4-vinylpyridine solid phase

• Particles incorporated into the walls of the tubing for essentially no particle release

Applications:• Non-polar and mid-polar

compounds

TracePLOT TG-BOND S GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.32 15 10 26006-6000 1 Each30 10 26006-6030 1 Each

0.53 30 20 26006-6090 1 Each

TracePLOT TG-BOND U GC columnsColumns for analysis of polar compounds

• Polar, divinylbenzene ethylene glycol/dimethylacrylate phase

• Particles incorporated into the walls of the tubing for essentially no particle release

Applications:• Analysis of polar compounds

TracePLOT TG-BOND U GC columns

ID (mm) Length (m)Film Thickness (μm) Cat. No. Quantity

0.32 15 10 26007-6000 1 Each30 10 26007-6030 1 Each

0.53 30 20 26007-6090 1 Each

TracePLOT particle traps for GC instrumentsProvides a safeguard from dislodged particles entering the detector

• Provides a safeguard from dislodged particles entering the detector

TracePLOT particle traps for GC instruments

Description ID (mm) Cat. No. Quantity

PLOT Particle Trap 2.5m x 0.25mm 0.25 60180-862 1 EachPLOT Particle Trap 2.5m x 0.32mm 0.32 60180-860 1 EachPLOT Particle Trap 2.5m x 0.53mm 0.53 60180-861 1 Each

Page 86: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-077

GC reagentsMaking the undetectable, detectable

Improve separation and detection for GC and GC-MS applications with our selection of derivatization reagents.

For more information visit thermofisher.com/GCreagents

The ideal derivatization procedure will:• Accomplish the desired modification.

• Proceed quantitatively, or at least reproducibly.

• Produce products that are readily distinguishable and separable from the starting materials.

• Proceed rapidly with simple and straightforward laboratory techniques that will be both selective and applicable to a number of similar compounds.

• Involve reagents and reactions that present no unusual hazards.

Why derivatize:• To make a compound that otherwise could

not be analyzed by a particular method suitable for analysis.

• To improve the analytical efficiency of the compound.

• To improve the detectability of the compound.

Page 87: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-078

GC

columns and accessories

Silylation reagents

BSTFA and BSTFA + TMCSFor excellent chromatographic separations and difficult-to-silylate compounds

• Increased volatility makes it possible to derivatize smaller molecules with which the TMS derivatives elute with the byproducts from BSA

• Excellent for derivatizing fatty acid amides, slightly hindered hydroxyls and other compounds

• Catalyzed formulation is stronger than BSTFA alone

BSTFA and BSTFA + TMCS

Description Quantity Cat. No. Quantity

BSTFA 10 × 1mL ampules TS-38830 1 Pack25g TS-38828 1 Each100g X TS-38829 1 Each

BSTFA + 1% TMCS 10 × 1mL ampules TS-38831 1 Pack10g TS-38832 1 Each25g TS-38833 1 Each100g X TS-38834 1 Each

BSTFA + 10% TMCS 10 × 1mL ampules TS-38840 1 Pack

X in the ordering table indicates that hazardous shipping charges apply.

MSTFA and MSTFA + 1% TMCSOffers maximum volatility

• Trimethylsilyl donor strength comparable to BSA and BSTFA

• Reacts to replace labile hydrogens on a wide range of polar compounds with a Si(CH3)3 group

• Used to prepare volatile and thermally stable derivatives for GC and GC-MS

• Addition of Thermo Scientific TMCS aids derivatization of amides, secondary amines and hindered hydroxyls not derivatized by MSTFA alone

MSTFA and MSTFA + 1% TMCS

Description Quantity Cat. No. Quantity

MSTFA 10 × 1mL ampules TS-48910 1 Pack10g TS-48911 1 Each25mL TS-48913 1 Each100mL X TS-48914 1 Each

MSTFA + 1% TMCS 10 × 1mL ampules TS-48915 1 Pack

X in the ordering table indicates that hazardous shipping charges apply.

thermofisher.com/chromatographyconsumables

Page 88: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-079

BSAThe perfect reagent for rapid silylation reactions

• Highly reactive trimethylsilyl donor that reacts quantitatively to form volatile, stable TMS derivatives

• Reacts quickly and quantitatively under mild conditions with a variety of compounds

• Derivatizes alcohols, amines, amides, carboxylic acids, phenols, steroids, biogenic amines and alkaloids

BSA

Description Quantity Cat. No. QuantityBSA 10 x 1mL TS-38836 1 Pack

Silylation grade solventsManufactured to meet your exact silylation needs

• Purified, dried and packaged under nitrogen in convenient 50mL Hypo-Vial Sample Storage Vials

• Supplied with elastomer septa, allowing immediate access to the sample without exposure to moisture and oxygen

• Use polar solvents (acetonitrile, dimethylformamide, dimethylsulfoxide, pyridine, tetrahydrofuran) to facilitate reactions; nonpolar organic solvents may be used, but they will not accelerate the rate of reaction

PyridineMW 79.10bp 115.2˚C

O

TetrahydrofuranMW 72.10

bp 66˚C

Silylation grade solvents

Description Quantity Cat. No. QuantityAcetonitrile 50mL X TS-20062 1 EachDimethylformamide (DMF) 50mL X TS-20672 1 EachDimethylsulfoxide (DMSO) 50mL X TS-20684 1 EachPyridine 50mL X TS-27530 1 EachTetrahydrofuran (THF) 50mL X TS-27860 1 Each

X in the ordering table indicates that hazardous shipping charges apply.

Learn more at thermofisher.com/GCsreagents

Page 89: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-080thermofisher.com/chromatographyconsumables

GC

columns and accessories

MTBSTFA and MTBSTFA + 1% TBDMCSOffers stable TBDMS (tert-butyldimethylsilyl) derivatization

• Derivatizes hydroxyl, carboxyl, thiol and primary and secondary amines

• Typical yields are >96%

• Reaction byproducts are neutral and volatile

• Silylating potential increased by adding 1% TBDMCS

MTBSTFA and MTBSTFA + 1% TBDMCS

Description Quantity Cat. No. Quantity

MTBSTFA 5mL ampules TS-48920 1 EachMTBSTFA + 1% TBDMCS 10 × 1mL TS-48927 1 Pack

TMSI (N-Trimethylsilylimidazole)The strongest silylator available for carbohydrates and steroids

• Reacts quickly and smoothly with hydroxyls and carboxylic acids, but not with amines

• Used in the derivatization of alcohols, phenols, organic acids, steroids, hormones, glycols, nucleotides and narcotics

• Excellent for C1 through C5 fatty acids in serum and urine

TMSI

Description Quantity Cat. No. Quantity

TMSI (N-Trimethylsilylimidazole)

10 × 1mL ampules TS-88623 1 Pack

25g TS-88625 1 Each100g TS-88626 1 Each

Page 90: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-081

HMDS (Hexamethyldisilazane)The popular choice for silylation of sugars and related substances

• Greatly extends the practical range of GC, improving chromatographic results

• Suitable for deactivating and coating chromatographic supports

• Monofunctional, making polymerization not possible and eliminating surface moisture

HMDS

Description Quantity Cat. No. Quantity

HMDS (Hexamethyldisilazane) 25g TS-84770 1 Each

TMCS (Trimethylchlorosilane)An excellent catalyst for difficult-to-silylate compounds

• Excellent adjunct for forming trimethylsilyl ethers for GC determinations

• Used to prepare TMS derivatives of organic acids

TMCS

Description Quantity Cat. No. Quantity

TMCS 25g TS-88530 1 Each

MOX (Methoxamine) reagentUseful for preparing oximes of steroids and ketoacids prior to silylation

• 2% methoxyamine HCl (M.W. 83.51) in pyridine

• Prevents formation of multiple derivatives when enols are present during silylation

MOX Reagent

Description Quantity Cat. No. Quantity

MOX (Methoxamine) Reagent (2% methoxyamine HCl in pyridine)

10mL TS-45950 1 Each

Learn more at thermofisher.com/GCsreagents

Page 91: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-082thermofisher.com/chromatographyconsumables

GC

columns and accessories

Tri-Sil HTP (HMDS:TMCS:Pyridine) reagentReagent-catalyst mixture for one-step derivatization

• Derivatizes carbohydrates, phenols, steroids, sterols, organic acids, alcohols and some amines

• Useful for rapid production of TMS derivatives of polar compounds for gas chromatographic determination and biochemical synthesis

• The versatility, speed and ease of use of Tri-Sil HTP Reagent has made it the most widely used silylation formulation available

Tri-Sil HTP reagent

Description Quantity Cat. No. Quantity

Tri-Sil HTP Reagent HMDS:TMCS:Pyridine (2:1:10)

10 × 1mL ampules TS-48999 1 Pack

Tri-Sil HTP Reagent HMDS:TMCS:Pyridine (2:1:10) 50mL X TS-49001 1 Each

X in the ordering table indicates that hazardous shipping charges apply.

Tri-Sil BP (BSA:Pyridine) reagentDerivatizes alcohols, phenols, organic acids, aromatic amides and amines

Tri-Sil BP Reagent reacts with:

• Alcohols, phenols, some enols and other hydroxyl and polyhydroxyl compounds to from trimethylsilyl esters

• Organic acids to form trimethylsilyl esters

• Aromatic amides to form N-trimethylsilyl derivatives

• Amino acids to form both N- and O-trimethylsilyl derivatives

• Amines to form N-trimethylsilyl derivatives

Tri-Sil BP reagent

Description Quantity Cat. No. Quantity

Tri-Sil BP Reagent (2.5mEq/mL BSA in pyridine) 25mL TS-49012 1 Each

Page 92: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-082

Tri-Sil TBT (TMSI:BSA:TMCS) reagentA catalyzed silylation reagent formulation containing three parts TMSI, three parts BSA and two parts TMCS

• Converts all classes of hydroxyl groups to TMS ethers

• Under usual conditions, the reaction is complete in a short period of time at 60 to 80°C, although very hindered hydroxyls may require several hours

Tri-Sil TBT reagent

Description Quantity Cat. No. Quantity

Tri-Sil TBT Reagent TMSI:BSA:TMCS (3:3:2)

10 × 1mL ampules TS-49016 1 Pack

Tri-Sil TP (TMSI:Pyridine) reagentDerivatizes hydroxyl compounds, particularly carbohydrates

• Silylates alcohols and phenols, organic acids, hydroxylamines, amino acids, carbohydrates, flavonoids, glycols and polyglycols, nucleotides, steroids, hydroxyl acids, barbiturates, narcotics, indoles and vitamins

• Does not react with amines

• May be used with water as long as there is enough reagent present to react with both the water and the sample

Tri-Sil TP reagent

Description Quantity Cat. No. QuantityTri-Sil TP Reagent TMSI: Pyridine (1:4)

10 × 1mL ampules TS-49230 1 Pack

Tri-Sil TP Reagent TMSI: Pyridine (1:4) 25mL TS-49231 1 Each

Learn more at thermofisher.com/GCsreagents

Page 93: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-084thermofisher.com/chromatographyconsumables

GC

columns and accessories

Acylation reagents

PentafluoropropanolPurified for GC-MS applications

• Addition of fluorine atoms into compounds greatly enhances the sensitivity of certain detectors for all those materials

• Carboxylic acids can be derivatized using a two-step reaction involving reaction with anhydride, followed by a fluorinated alcohol

Pentafluoropropanol

Description Quantity Cat. No. Quantity

Pentafluoropropanol 10 x 1mL ampules TS-65195 1 Pack

MBTFAFor trifluoroacylating primary and secondary amines, hydroxyl and thiol groups and carbohydrates

• Reacts under non-acidic conditions

• Principle byproduct from the derivatization reaction is N-methyltrifluoroacetamide, which is stable, volatile and does not present problems in subsequent GC

• Produces very volatile derivatives of carbohydrates

• Can be used to selectively acylate amines in the presence of hydroxyl and carboxyl groups that have been protected by silylation

MBTFA

Description Quantity Cat. No. Quantity

MBTFA [N-Methyl-bis(trifluoroacetamide)

10 × 1mL ampules TS-49700 1 Pack

25mL TS-49703 1 Each

100mL X TS-49704 1 Each

5g TS-49701 1 Each

X in the ordering table indicates that hazardous shipping charges apply.

Page 94: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-085

Perfluoroacylimidazoles (HFBI and TFAI)Offer effective acylation of hydroxyl groups and primary and secondary amines

• Reactions are smooth, quantitative and produce no acid byproducts

• Excellent for FID and ECD techniques

• Derivatives are volatile, despite size of group

• Closely bound fluorines contribute to stability

Perfluoroacylimidazoles (HFBI and TFAI)

Description Quantity Cat. No. Quantity

HFBI 5g d TS-44211 1 Each

TFAI 10 x 1mL ampules TS-48882 1 Pack

d indicates that additional dry ice and/or freight charges apply.

R Name M.W. Boiling Point

C3F7 HFBI 264.10 57 to 58°C/10mmCF3 TFAI 164.08 38 to 40°C/14mm

Perfluoro acid anhydrides (TFAA, PFAA and HFAA)Highly purified for optimal preparation of fluoracyl derivatives

• Used to prepare fluoracyl derivatives for GC-MS

• Produce stable volatile derivatives for FID and ECD techniques

Perfluoro acid anhydrides

Description Quantity Cat. No. Quantity

TFAA (Trifluoroacetic Acid Anhydride) 100g X TS-67363 1 Each

PFAA (Pentafluoropropionic Acid Anhydride)

10 × 1mL ampules TS-65193 1 Pack

PFAA 25g X TS-65192 1 EachPFAA 100g X TS-65191 1 EachHFAA (Heptafluorobutyric Acid Anhydride)

10 × 1mL ampules TS-63164 1 Pack

HFAA 25g X TS-63163 1 EachHFAA 100g X TS-63162 1 Each

X in the ordering table indicates that hazardous shipping charges apply.

thermofisher.com/GCreagents

Page 95: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

GC

columns and accessories

Alkylation reagents

Pentafluorobenzyl bromide (PFBBr)For electron capture GC analysis of carboxyl acids, phenols and sulfonamides

• Fast reaction times for extraction alkylation technique: ~20 minutes

• Derivatives are highly EC-sensitive

• Analysis of trace organics in asphalt

Methylate reagent (DMFDMA)For easy, effective preparation of methyl esters from fatty acids and amino acids

Advantages for preparation of methyl esters for gas chromatography:

• Speed: the reaction is complete upon dissolution (except long chain solid acids)

• No water washing, extraction or concentration of derivatives required

• No water formed

• Convenient: ready-to-use reagent contains 2mEq/mL pyridine

Methylate reagent

Description Quantity Cat. No. Quantity

Methylate Reagent (N, N-Dimethylformamide dimethyl acetal)

25mL TS-49350 1 Each

thermofisher.com/chromatographyconsumables 5-086

Page 96: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

MethElute reagent (TMPAH)Provides accurate sensitive on-column methylation

• 0.2M trimethylanilinium hydroxide (TMPAH) in methanol solution

• For quantitative methylation and detection of barbiturates, sedatives, xanthine bases, phenolic alkaloids and phenytoin by gas chromatography

• Single quantitative peak for each substance

• Comparable to or better than UV/TLC method (when phenobarbitol and phenytoin are present, GC is superior to UV/TLC)

• Coefficient of variation is 5% or less

• Detects barbiturates to 0.2mg/dL

MethElute reagent

Description Quantity Cat. No. Quantity

MethElute Reagent (TMPAH) 10mL TS-49300 1 Each

MethElute Reagent (TMPAH) 12 × 1mL ampules TS-49301 1 Pack

thermofisher.com/GCreagents5-087

Learn more at thermofisher.com/GCsreagents

Page 97: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-088

GC

columns and accessories

thermofisher.com/chromatographyconsumables

Siliconizing fluids

Water-soluble siliconizing fuidAttaches the silane polymer, octadecyltrialkosilane, to make the surface inert or polymerizes to create an inert film

• Easy-to-use silane monomer solution that is supplied as a 20% solid solution in a mixture of diacetone alcohol and tertiary butyl alcohol

• Greater resistance to base hydrolysis than other surface treatments

• Can be used on plastic surfaces

Water-soluble siliconizing fluid

Description Quantity Cat. No. Quantity

Siliconizing Fluid-Water Soluble 120mL X TS-42799 1 Each

X in the ordering table indicates that hazardous shipping charges apply.

Hydrocarbon-soluble siliconizing fluidAttaches a short-chain silane polymer to make the surface inert or polymerizes to create an inert film

When applied to glass, quartz or similar materials, the unhydrolyzed chlorines present on the chain react with surface silanols to form a neutral, hydrophobic and tightlyCbonded film over the entire surface.

• Soluble in organic solvents

• Excellent for modifying metals, glass, ceramics and fiber optics

• Can be used for certain plastic surfaces

• Well-suited for treatment of GC injection port liners

Hydrocarbon-soluble siliconizing fluid

Description Quantity Cat. No. Quantity

Siliconizing Fluid-Hydrocarbon Soluble 120mL X TS-42800 1 Each

Siliconizing Fluid-Hydrocarbon Soluble 480mL X TS-42801 1 Each

X in the ordering table indicates that hazardous shipping charges apply.

Page 98: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

Reacti-Therm heating and stirring modulesReliable and easy-to-use for constant temperatures• Uniform, stable heating: steady temperature incubation between ambient plus

10°C to 200°C

• LED display: match digital display to in-block thermometer to calibrate temperature set-point

• Modular design: switch aluminum blocks and vials; attach compatible evaporator manifold

• In-block temperature control option by Remote Temperature Probe, an optional accessory to allow temperature regulation from block wells or actual sample vials

• Magnetic stirrers for heating / stirring module for simultaneous stirring of samples in multiple vials

Applications:• General sample incubation

and evaporation in a variety of tube and vial sizes

• Silylation, alkylation and acylation derivatization reactions for GC sample preparation

• Protein hydrolysis and vacuum hydrolysis reactions for amino acid analysis by HPLC

Thermo Scientific™ Reacti-Therm™ Heating Modules

Type Size of Unit Cat. No. Quantity

Heating Function Single-block TS-18822 1 EachTriple-block TS-18824 1 Each

Remote Temperature Probe TS-18820 1 Each

Reacti-Therm heating and stirring modules

Type Size of Unit Cat. No. QuantityHeating and Stirring Function Single block TS-18821 1 Each

Triple-block TS-18823 1 EachMagnetic Stirrers for 3.0, 5.0 & 10.0mL Thermo Scientific™ Reacti-Vial™

TS-16000 6 Pack

Magnetic Stirrers for 0.3 and 1mL Small Reaction Vials TS-16010 6 Pack

Reacti-Vap evaporatorsManifolds for easy sample evaporation

• Integrated pressure-relief valve protects against excessive gas-flow and dangerous pressure build up

• Easy set-up: attach to corresponding Reacti-Therm Module, attach tubing from gas supply, and lower into position over samples and start gas flow

• Choose 9-port or 27-port model for compatibility with single-block and triple-block Reacti-Therm Modules, respectively

Applications:• General sample incubation

and evaporation in a variety of tube and vial sizes

• Silylation, alkylation and acylation derivatization reactions for GC sample preparation

Thermo Scientific™ Reacti-Vap™ Evaporators

No. of Ports For Use With Cat. No. Quantity

9 Single-block Reacti-Therm Module TS-18825 1 Each27 Triple-block Reacti-Therm Module TS-18826 1 Each

Gas regulators

Description Cat. No. Quantity

1/8" tube fitting 60181-625 1 Each

1/4" tube fitting 60181-626 1 Each

Page 99: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-089

GC

columns and accessories

thermofisher.com/chromatographyconsumables

Reacti-Block aluminum blocksOptimal thermal conductivity

• Constructed of an aluminum alloy for optimal thermal conductivity

• Each Thermo Scientific™ Reacti-Block™ aluminium block contains a thermometer well

• Block dimensions are 9.4 L x 7.5 W x 5.1cm H for all blocks except for F, G, J and M which have a depth (height) of 7.6cm

Thermo Scientific™ Reacti-Block™ aluminum llocks

Description Cat. No

Reacti-Block A-1Holds 13 x 0.3mL or 1mL Reacti-Vials; 13 holes/14mm dia. x 23mm deep TS-18801

Reacti-Block B-1Holds 9 x 3mL or 5mL Reacti-Vials; 9 holes/21mm dia. x 32mm deep TS-18802

Reacti-Block C-1Holds 13 x 3.5mL Screw Cap Septum Vials; 13 holes/15mm dia. x 34mm deep TS-18803

Reacti-Block Z-1Holds 9 x 0.1mm Reacti-Vials; 9 holes/12mm dia. x 21mm deep TS-18804

Reacti-Block M-1Holds 6 x 27.5mL Reacti-Vials; 6 holes/28.5mm dia. x 70mm deep TS-18811

Reacti-Block S-1Holds 13 x 13mm dia. Test Tubes; 13 holes/14mm dia. x 45mm deep TS-18816

Reacti-Block T-1Holds 9 x 16mm dia. Test Tubes; 9 holes/17mm dia. x 45mm deep TS-18817

Reacti-Block U-1Holds 8 x 20mm dia. Test Tubes; 8 holes/21mm dia. x 45mm deep TS-18818

Reacti-Block V-1Holds 17 Microcentrifuge Test Tubes; 17 holes/11mm dia. x 45mm deep TS-18819

The Reacti-Block aluminium blocks below are designed to be used exclusively with the Reacti-Therm modules. The hole patterns do not match the needle configuration of Thermo Scientific™ Reacti-Vap™ Evaporators.

Description Cat. No

Reacti-Block FHolds 8 x 6mL Vacuum Hydrolysis Tubes; 8 holes/10mm dia. x 64mm deep TS-18806

Reacti-Block GHolds 4 x 18mL Vacuum Hydrolysis Tubes; 4 holes/19mm dia. x 64mm deep TS-18807

Reacti-Block JBlank/no holes (for custom drilling) 7.6cm tall TS-18809

Reacti-Block KBlank/no holes (for custom drilling) 5.1cm tall TS-18810

Reacti-Block LHolds 16 x 0.1mL Reacti-Vials; 16 holes/12mm dia. x 21mm deep TS-18812

5-090

Page 100: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-091

Reacti-Vap replacement parts

Description Cat. No. Quantity

Reacti-Vap Replacement Tube Kit2.5 inch (64mm) (Tubes and Plugs) TS-18782 9 Pack

Reacti-Vap PTFE-Coated Needles 102mm (4in) Length TS-18784 9 PackReacti-Vap PTFE-Coated Needles 152mm (6in) Length TS-18786 9 PackReplacement Luer-Lok Fitting TS-18827 1 EachReplacement Height Adjustment Knob TS-18829 1 EachReplacement Metal Rod TS-18831 1 Each

Reacti-Therm thermometersThermometers specially designed for use in dry block heaters

• Mercury-free: alcohol-filled for greater safety

• PTFE coating ensures that glass is impervious to corrosive materials

• Shock-resistant glass and coatings

• Standard laboratory size: 225mm length x 8mm diameter

• Compatible for use in Thermo Scientific™ Reacti-Therm™ Heating Modules and other laboratory equipment

Reacti-Therm thermometers

Min. Temperature (°C) Max. Temperature (°C) Cat. No. Quantity

0 100 TS-18914 1 Each0 200 TS-18915 1 Each

Reacti-Vap replacement parts

Vacuum hydrolysis tubesFor fast, effective protein and peptide hydrolysis

• The upper temperature limit of the Vacuum Hydrolysis Tubes is 260°C; however, do not heat the tubes greater than 100°C in an oven

• Vacuum hydrolysis tubes fit conveniently into Reacti-Block aluminium heating blocks

Vacuum hydrolysis tubes

Volume (mL) OD (mm) Length (mm) Cat. No. Quantity

1 8 60 TS-29570 1 Each6 10 150 TS-29571 1 Each18 19 100 TS-29572 1 Each

Learn more at thermofisher.com/GCsamplehandling

Page 101: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-092thermofisher.com/chromatographyconsumables

GC

columns and accessories

Reacti-Vial small reaction vialsAn internal cone makes small sample handling easy and convenient

• Extra thick glass wall magnifies the sample, making these vials ideal for observing chemical reactions

• Amber vials available for light-sensitive compounds

• Supplied complete with Open-Top Screw Caps and PTFE/Rubber Discs

Applications:• Residue isolation, derivative

preparation, maximum sample retrieval, moisture protection, sample storage, precipitations, centrifugations, solvent evaporation

Thermo Scientific™ Reacti-Vial™ small reaction vials

Capacity Cat. No. QuantityAmber1mL TS-13097 12 Pack5mL TS-13099 12 PackClear100μL TS-13100 12 Pack300μL TS-13220 12 Pack1mL TS-13221 12 Pack3mL TS-13222 12 Pack5mL TS-13223 12 Pack10mL TS-13225 12 Pack

Thermo Scientific Tuf-Bond PTFE/Silicone discsDiscs that combine the inertness of PTFE with the resealability of silicone

• Structurally bonded PTFE to silicone; no cement to leak out of your sample after needle penetration

• Reseals instantly, puncture after puncture

• Autoclavable

• Compresses to maintain a tight seal forcing the PTFE to conform to the sealing surface

• Standard syringe and GC needles penetrate the entire disc with ease

Thermo Scientific Tuf-Bond PTFE/Silicone discs

Diameter (mm) Fits Cat. No. Quantity

8 100μL Reacti-Vial Small Reaction Vials, 1.5mL Screw Cap Septum Vials TS-12708 72 Pack

120.3 and 1mL Reacti-Vial Small Reaction Vials, 3.5mL Screw Cap Septum Vials

TS-12712 72 Pack

13 7mL Screw Cap Septum Vials TS-12713 72 Pack

16 14mL Screw Cap Septum Vials; 15mL (0.5 oz.) Screw Cap Bottles TS-12716 72 Pack

18 3 and 5mL Reacti-Vial Small Reaction Vials TS-12718 72 Pack

2225 and 40mL Screw Cap Septum Vials, 240mL (8 oz.) Screw Cap Bottles, 10mL Reacti-Vial

TS-12722 72 Pack

Page 102: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-093

PTFE/Rubber laminated discsProvides a highly inert and unreactive seal

• Constructed of white pharmaceutical rubber with PTFE bonded to one side

• Discs are autoclavable with no loss of integrity after heating above 100°C for 5 hours

Open-Top screw capsProvide inert, air-tight seal and direct puncture-access to sample with a syringe needle

• Fits into Reacti-Vial Small reaction vials

• Used with PTFE/Rubber laminated discs

Open-Top screw caps

Fits Cat. No. Quantity

3 and 5mL Reacti-Vials TS-13218 72 Pack0.3 and 1.0mL Reacti-Vials, 3.5mL Screw Cap Septum Vial TS-13215 72 Pack

10mL Reacti-Vials, 40mL Screw Cap Septum Vials TS-13219 72 Pack

Screw cap septum vialsEconomy, convenience and versatility in a vial and closure system

• Flat bottom vials

• Heavy-duty flip-top divider box provides easy access to vials, caps and septa and offers a convenient sample storage center

• Storage of reagents and standards under complete seal with instant syringe access

Screw cap septum vials

Capacity (mL) Cat. No. Quantity

Clear3.5 TS-13019 72 Pack

7 TS-13028 72 Pack

PTFE/Rubber laminated discs

Diameter (mm) Fits Cat. No. Quantity

120.3 and 1mL Reacti-Vial Small Reaction Vials, 2 and 3.5mL Screw Cap Septum Vial

TS-12412 72 Pack

18 3 and 5mL Reacti-Vial Small Reaction Vials; 10 and 25mL Reacti-Flask TS-12418 72 Pack

Ordering Alerts: Septa not included with vials; must be ordered separately.

Learn more at thermofisher.com/GCsamplehandling

Page 103: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-094thermofisher.com/chromatographyconsumables

GC

columns and accessories

Mininert valvesExcellent closures for chemicals that deteriorate or evaporate through conventional vial caps and seals

Thermo Scientific™ Mininert Valves are screw caps that have integrated resealable valves to allow repeated and unlimited syringe-needle access to samples. Slide the valve one way to open the needle-port. Slide the valve back to close and completely seal the close.

• Available in two sizes – 20mm (thread size 20/400) and 27mm (thread size 24/400) to fit 3 and 5mL Reacti-Vial Small Reaction Vials and 40mL Screw Cap Septum Vials, respectively

• Precision crafted from PTFE plastic for repeated use and chemical resistance

• Valve design eliminates the septum-boring that occurs with repeated puncture of traditional septa

Mininert valves

Size (mm) Fits Cat. No. Quantity

20 Fits 3 and 5mL Reacti-Vial Small Reaction Vials TS-10135 12 Pack

27 Fits 40mL Screw Cap Septum Vials TS-10130 12 Pack

Page 104: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

GC and GC-MS instrumentsOur gas chromatography and mass spectrometry instruments offer solutions to food, environmental, pharmaceutical laboratories and industrial customers. Our instruments stimulate to advance scientific knowledge, enable drug discovery and to improve manufacturing processes. Using our GC and GC-MS you can expect the best results and highest level of productivity to keep your research or processes moving smoothly.

TRACE 1300 Series GC• User-installable injectors and detectors

• Easy adoption of standard GC methods

• Unmatched detector sensitivity in trace analysis

• Increased robustness of injector technology

• Shorter sample cycle time

For routine GC and GC-MS laboratories that need flexibility for a wide range of applications, the Thermo Scientific™ TRACE™ 1300 Series GC Gas Chromatograph is the latest technology to simplify workflow and increase analytical performance.

The TRACE 1300 Series offers the most versatile GC platform in the market, with unique instant connect modularity for ground-breaking ease of use and performance, setting a new era in GC technology. GC users now have the unique ability to easily configure the system themselves, to increase throughput or for a rapid exchange of configurations, with the added benefit of continuous operation since modules can be swapped and routine maintenance performed offline to fit laboratory’s schedule.

Visit thermofisher.com/GC

TriPlus RSH autosampler• Reliable GC and GC-MS automation

• Liquid injection/headspace/SPME, all-in-one unattended sequence

• Enhanced productivity and powerful versatility in sample preparation

The Thermo Scientific™ TriPlus™ RSH Autosampler offers scalable flexibility from simple liquid injection to extended sample preparation. An innovative Automated Tool Change (ATC) station addresses sampling demand and selects the most suitable syringe during a sequence. Up to 6 different syringes can be programmed in a sequence for extended sample preparation capabilities and different sampling modes (liquid, HS, SPME). Unsurpassed sample handling flexibility combined with high sample capacity, places no limits even to more stringent productivity requirements. Multiple sample trays increase unattended operation up to 972 x 2mL vials. The unique Bottom Vial Sensing feature secured syringe depth positioning in your vial for the last µL sample. Even nanovolume injections through the use of plunger-in-needle syringes can be programmed in a flexible sequence. All these, combined with large volume injections deliver unsurpassed sample handling flexibility.

5-095

Page 105: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

GC

columns and accessories

AS 1310 155-vial Autosampler mounted on a TRACE 1300 GC with ISQ Mass Spectrometer

AI 1310 mounted onto a TRACE 1310 GC

AI/AS 1310 autosampler• Automated liquid injection systems for all

Thermo Scientific GC and GC-MS systems

• Performance and simplicity in liquid sampling

• “Tool-Free” upgradability from 8 to 155 vial positions

Engineered to meet the highest level requirements of ruggedness and ease-of-use, the AI/AS 1310 automatic sampling system is ideal for high throughput and QA/QC control on the Thermo Scientific GC and GC/MS product portfolio. Utmost precision and ease-of-use of the plug and inject concept are combined in the available configurations: 8-position single module system for small batches of samples; 155 position tray system for high sample throughput. Boost productivity further with the Gemini configuration, which allows two autosamplers to be mounted on the same GC, serving two injection ports simultaneously.

TriPlus 300 Headspace autosampler• Unprecedented productivity and accelerated analytical results

• High throughput operations with expanded sample capacity

• Ideal for organic volatiles analysis

The Thermo Scientific™ TriPlus™ 300 Headspace valve-and-loop autosampler offers a quick start-up and enables reliable, unattended and high throughput operations with expanded sample capacity. Its ability to fully comply with existing methods in pharmaceutical, forensic and environmental laboratories makes TriPlus 300 HS the product of choice for automated and dependable organic volatiles determinations.

Combined with the user-configurable TRACE 1300 Series GC and supported by a range of chromatography data systems that offer comprehensive system control, TriPlus 300 HS delivers unprecedented productivity and accelerated analytical results within the laboratory workflow.

5-096thermofisher.com/chromatographyconsumables

Page 106: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-097

ISQ Series Single Quadrupole GC-MS• Unique Full Source Removal™ capability delivers maximum uptime and

unstoppable productivity

• ExtractaBrite™ solid, inert ion source provides robust operations and low detection limits

• Versatile and flexible for a broad range of applications

The Thermo Scientific™ ISQ™ Series single quadrupole GC-MS system features time-proven technology developed with the accumulation of almost 50 years of mass spectrometry innovation, offering an affordable and robust solution. This GC-MS series offers operational simplicity, proven dependability, and unstoppable productivity.

The ISQ QD GC-MS offers quality design, MS operational simplicity, and proven dependability for QA/QC and low-to medium-throughput production environments, as well as in teaching and academic facilities.

For analytically-demanding, high-throughput laboratories, requiring utmost sensitivity and unstoppable productivity, the ISQ LT GC-MS does not need to be vented to exchange the source, and it boasts the lowest detection limits and unlimited flexibility.

Visit thermofisher.com/ISQ7000

TSQ 9000 Triple Quadrupole GC-MS/MS systemSatisfy your routine laboratory’s current and future analytical needs for truly unstoppable performance with the Thermo Scientific™ TSQ™ 9000 triple quadrupole GC-MS/MS system. Deliver high sensitivity for more routine analysis. Minimize maintenance intervals with routine-grade robustness. Operate with technology, flexible method development and powerful reporting tools designed for optimal productivity. Achieve quality results on time, every time with easy-to-use routine workflows. Fully upgrade from base to advanced configurations to boost flexibility and performance when you need it.

Visit thermofisher.com/TSQ9000

Page 107: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

5-098thermofisher.com/chromatographyconsumables

GC

columns and accessories

Q Exactive GC Orbitrap GC-MS/MSBring the power of the first-ever combination of high-resolution gas chromatography (GC) and high-resolution/accurate-mass (HR/AM) Orbitrap mass spectrometry to your laboratory. The Thermo Scientific™ Q Exactive™ GC Orbitrap™ GC-MS/MS system provides comprehensive characterization of samples in a single analysis for the highest confidence in compound discovery, identification, and quantitation. Q Exactive GC offers the quantitative power of a GC triple quadrupole MS combined with the high performance, full scan HR/AM capabilities that are only possible with Orbitrap MS technology.

Visit thermofisher.com/qexactivegc

Satisfy your routine laboratory’s current and future analytical needs for truly unstoppable performance with the Thermo Scientific TSQ 9000 triple quadrupole GC-MS/MS system. Deliver high sensitivity for more routine analysis. Minimize maintenance intervals with routine-grade robustness. Operate with technology, flexible method development and powerful reporting tools designed for optimal productivity. Achieve quality results on time, every time with easy-to-use routine workflows. Fully upgrade from base to advanced configurations to boost flexibility and performance when you need it.

Page 108: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

Trademark information The Thermo Scientific name, the Thermo Scientific logo and the following trademarks are the property of Thermo Fisher Scientific Inc. and/or its subsidiaries:

Index

Acclaim

Accucore

Aquasil

AVCS

BetaBasic

BetaMax

BETASIL

BioBasic

BioLC

GuardGOLD

Chromacol

Chromacol Gold

Chromeleon

Chromseal

Click-On

COOL POCKET

Core Enhanced Technology Corona

Crimpmate

Defender

DELTABOND

Dionex

DNAPac

DNASwift

EASY-Column

EASY-Spray

Exactive

FOCUS

FocusLiner

GFM Pro

GLD Pro

GlycanPac

GOLD

HOT POCKET

Hypercarb

HyperREZ

HyperSep

Hypersil

Hypersil GOLD

Hypersil GOLD aQ

HyPURITY

HyPURITY ADVANCE

HyPURITY Aquastar

I-D

Integral

IonPac

IonSwift

ISQ

Javelin

Kappa

LinerGOLD

LTQ FT

LTQ Velos

LTQ XL

MAbPac

MacroVial

Micro+

MicroBead

MicroSert

Micro-V

Mininert

MSQ

Nanobore

nanoViper

National

NeverVent

OmniPac

Orbitrap

PepMap

PepSwift

Pierce

Plate+

PolarisQ

Polyspring

PolyVial

ProPac

ProSwift

Reacti-Block

Reacti-Therm

Reacti-Vap

Reacti-Vial

Retain

SCI-VI

SMART Digest

Snap-It

SOLA

SureStop

Syncronis

Target

Target2

Target Colorband

Target DP

Thermo Scientific

Titan3

TRACE TraceGOLD

TracePLOT Transcend

Trinity

TriPlus

TriPlus RSH

TSQ

Tuf-Bond

UltraFast

UNIFILTER

UNIGUARD

Vanquish

Vari-Clean

Verify

Viper

Virtuoso

WebSeal

Page 109: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

thermofisher.com/chromatographyconsumables

Index

The following brands, trademarks or service marks are the property of the listed company and/or its subsidiaries. Every effort has been taken to ensure this list is accurate at the time of printing this catalog.

Aeris Phenomenex, Inc

Agilent Agilent Technologies, Inc

Agilent Technologies

Agilent Technologies, Inc

Alltima Merc, Inc.

Altex Beckman Coulter

Aminex Bio-Rad Laboratories, Inc

Ascentis Express Merc, Inc

ASTM ASTM International

Atlantis Waters Corporation

BAKERBOND Mallinckrodt Baker, Inc.

Beckman Coulter Beckman Coulter

Bio-Inert Pall Corporation

Bond Elut Agilent Technologies, Inc

Bottom-of-the-Bottle

Merc, Inc

Capcell Shiseido

Carbowax Dow Chemical Company

Cellosolve Dow Chemical Company

Cheminert Victrex plc

ChloroFiltr United Chemical Technologies

CHROMABOND Macherey-Nagel

Clean-Up United Chemical Technologies

CLICK-ON Scientific Glass Technology

Combi-Pal LEAP Technologies, Inc.

Cortecs Waters Corporation

CP-PoraBOND U Waters Corporation

CP-PoraPLOT Waters Corporation

CP-Select Waters Corporation

CP-Sil Waters Corporation

CTC LEAP Technologies, Inc.

Discovery Gilson Inc.

Discovery Merc, Inc

eVol Trajan Scientific Australia Pty Ltd

EVOLUTE Biotage AB

Florisil U.S. Silica Holdings Inc.

Gemini Phenomenex, Inc

Genesis Merc, Inc

Gilson YMC Ltd.

GOAL Dow AgroSciences

Halo Advanced Materials Technology

Hamilton Hamilton Company

Hitachi Hitachi, Ltd.

HP Hewlett-Packard Development Company

Inertsil GL Sciences, Inc

IntegraFrit New Objective, Inc

ISOLUTE Biotage AB

Jasco Jasco, Inc.

J'Sphere YMC CO., LTD

Jupiter Phenomenex, Inc

Kel-F 3M

Kinetex Phenomenex, Inc

Knauer Knauer

Kromasil AkzoNobel

Leap Leap Technologies, Inc

LiChrospher Merck

Luer-Lok Becton Dickinson

Luna Phenomenex, Inc

Merlin Merlin Instrument Company

Merlin Microseal Merlin Instrument Company

MP35N SPS Technology

NUCLEODUR Macherey-Nagel

Nucleoshell Macherey-Nagel

Nucleosil Macherey-Nagel

Oasis Waters Corporation

Parker Parker Hannefin Corporation

PE PerkinElmer

PEEK (Scientific Systems)

Victrex plc

PEEKsil SGE Analytical Science

PerkinElmer PE Corp.

Phenomenex Phenomenex, Inc

PicoFrit New Objective

Pinnacle Restek Corporation

Polar Plus Mallinckrodt Baker, Inc

Poroshell Agilent Technologies, Inc

Primesep SIELC Technologies

Prodigy Phenomenex, Inc

Purospher Merc, inc

RheBuild Waters Corporation

RheFlex Rheodyne LLC

Rheodyne Rheodyne LLC

SampliQ Agilent Technologies, Inc

Sep-Pak Waters Corporation

Septa BTO Chromatography Research Supplies

Shimadzu Shimadzu

Shodex Showa Denko

Shortix Scientific Glass Technology Exploitatie B.V

SilFlow SGE Analytical Science

SilTek Silcotek

SilTite SGE Analytical Science

Spherisorb Waters Corporation

SSI Scientific Systems

Strata Phenomenex, Inc

Styre Screen United Chemical Technologies

SunFire Waters Corporation

Sunshell ChromaNik

Supelclean Supelco, Inc

Supelco Merc, Inc

Supelcosil Supelco, Inc

Super Clean Scientific Glass Technology Exploitatie B.V

Symmetry Waters Corporation

Synergi Phenomenex, Inc

Teledyne/Tekmar Teledyne Tekmar Company

Tosoh Tosoh Corporation

TRITON X-100 Dow Chemical Company

TSKgel Tosoh Corporation

Valco Valco Instruments

Velcro Velcro Industries

Vespel DuPont de Nemours, Inc.

Viva Restek Corporation

VOCOL Merc, Inc

Vydac Millipore

Waters Waters Corporation

Waters Corp. Waters Corporation

WISP Waters Corporation

Xbridge Waters Corporation

XCHANGE SGE Analytical Science

Xterra Waters Corporation

YMCbasic YMC, Inc

YMC-Pack YMC, Inc

Zorbax Agilent Technologies, Inc

µ-Bondapak Waters Corporation

Trademark Owner Trademark Owner Trademark Owner

Page 110: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

Find out more at thermofisher.com/chromatographyconsumablesFor Research Use Only. Not for use in diagnostic procedures. © 2015, 2019 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. BR21443-EN 0619S

USA and Canada800 332 3331865 354 4616 [email protected]

France+33 (0)1 60 92 48 00 +33 (0)1 60 92 49 00 [email protected]

Germany+49 (0) 2423 9431 -20 or -21+49 (0) 6103 408 1640 fax [email protected]

United Kingdom+44 1928 534110+44 1928 534001 [email protected]

China800 810 5118 (free domestic call only)400 650 5118 (free domestic call only)+86 21 [email protected]

India+91 22 6716 2200/ 2240 +91 27 1766 2351+91 22 6716 2244 fax [email protected]

Japan0120-753-670 (free domestic call only)0120-753-671 fax (domestic only)[email protected]

Korea+ 82 (2) 3420-8600+ 82 (2) 3420-8688 [email protected]

[email protected]

Taiwan+886 [email protected]

Thermo Fisher Scientific Australia Pty Ltd 1300 735 292 (free call domestic)1800 067 639 [email protected]

Thermo Fisher Scientific New Zealand Ltd 0800 933 966 (free call domestic)0800 329 246 [email protected]

All Other Enquiries+44 (0) 1928 534 050+44 (0) 1928 534 049 [email protected]

How to order

Resources for chromatographers

Chromatography resource centerOur web-based resource centers provide technical support, applications, technical tips and literature to help move your separations forward.

For more information visit: thermofisher.com/chromatography

Technical supportFor support, please visit our website: thermoscientific.com/chromexpert

Page 111: C onnected chromatography solutions - Orion Scientific · Chromacol vials and closures 2-060 Electronic crimping and decrimping tools 2-091 Well plates for chromatography 2-093 GC

Sam

ple preparation