It’s easy to recognize why a Butler®

building system is such an ideal choice

for self-storage applications. It offers

design flexibility, fast construction,

superior performance, and low-

maintenance—all provided by a

reputable local Butler Builder®.

The photographs included in this guide

demonstrate the options available for

a Butler Self-Storage building system.

Also included are descriptions of the

building components, as well as other

options that may be considered. If you

have any questions, please contact your

Butler Builder.

BUTLER® SELF-STORAGE DESIGN AND SPECIFICATION GUIDE - LOW PITCH ROOFS

Door jambs and headers are constructed of pre-finished 18 gauge material, which is 2-1/2 times thicker than the industry standard 26 gauge material. Jambs and headers feature no exterior fasteners giving a clean, finished look.

1.

Your Butler Builder is a construction

professional who can handle every

phase of your construction project.

Only builders of the highest integrity

and reputation are selected to become

Butler Builders. They will work with

you to provide the building system you

want, on time and within your budget.

18 Gauge Header

18 Gauge Door Jamb

A.

The typical 10" bay utilizes a 9' 0" wide door, and a typical 12' 0" wide bay uses an 11" 0' wide door.

9' 0" wide door

A.

The interior structure features pre-punched columns and purlins for bolt together connections to simplify installation. The entire structure is zinc coated to inhibit rust.

Purlin

Column

B.

The interior structure has 5' purlin spacing standard, in some high snow load areas closer purlin spacing may be required.

5' Maximum

B.

Partition

Page 3: BUtler self-storageglcbuilt.com/.../butler-self-storage-design-specs-2015.pdf · 2017. 3. 30. · BUTLER® SELF-STORAGE DESIGN AND SPECIFICATION GUIDE - LOW PITCH ROOFS In insulated

29 gauge galvalume horizontal partition panel.

Rake angles close the gap between the partition panel and the underside of the roof.

2.

Rake Angle

Partition Panel

C.

26 gauge A-Type Panel is used at wall locations that do not have doors.

A-Type Panel

E.

Rake trim covers the end of the building while eave trim covers the side. Both rake and eave trims are used to accent the building and are normally the same color as the doors.

Rake Trim

Eave Trim

F.

When there is a change in foundation

grade, building steps will be required. For

steps 12" or less, the step trim color will

be determined by the rake trim color and

the starter strip color will be determined

by the roof color. For steps greater than

12", additional rake trim and A-Type panel

will be included at step. The starter strip

color will be determined by roof color.

Contact a Butler Regional Manager if you

have any questions about building steps.

Step TrimG.

BUTLER® SELF-STORAGE DESIGN AND SPECIFICATION GUIDE - LOW PITCH ROOFS

D.

12" Roof Step

Page 4: BUtler self-storageglcbuilt.com/.../butler-self-storage-design-specs-2015.pdf · 2017. 3. 30. · BUTLER® SELF-STORAGE DESIGN AND SPECIFICATION GUIDE - LOW PITCH ROOFS In insulated

BUTLER® SELF-STORAGE DESIGN AND SPECIFICATION GUIDE - LOW PITCH ROOFS

K. If an interior masonry fire separation is required, the structural framing includes exterior trim pieces to cover the fire separation.

Masonry Fire Separation

For interior fire separations, gypsum wallboard is installed over stud wall and taped. Number of sheets on each side of stud wall will vary based on fire rating needed.

THE BUTLER STANDARD: Includes 29 gauge Galvalume® liner panel to cover both sides, protecting the gypsum wallboard. The door jamb is widened for this additional material.

Gypsum Wallboard Fire Separations

I.

J.

An alternate way to accommodatea roof step is to use a rolling stepThis design can be used for steps upto 12" in height. Please contact the Butler Regional Manager forlimitations and other information.

Rolling Step

H.

GutterL. 26 gauge gutters and downspouts can match either the building or door color. If using the MR-24® roof system, the standard Butler gutter would be installed.

Downspout

3.

Page 5: BUtler self-storageglcbuilt.com/.../butler-self-storage-design-specs-2015.pdf · 2017. 3. 30. · BUTLER® SELF-STORAGE DESIGN AND SPECIFICATION GUIDE - LOW PITCH ROOFS In insulated

BUTLER® SELF-STORAGE DESIGN AND SPECIFICATION GUIDE - LOW PITCH ROOFS

In insulated buildings, 29 gauge liner panel is used to cover the wall insulation and protect it from damage.

4" or 6" wall insulation can be supplied by Butler®.

4.

Insulation

Liner Panel

M.

N.

Butler offers up to an R-38 (12") roof insulation. Shown above is a R-32 (10") roof insulation using R-5 thermal blocks. Contact a Butler Builder about meeting energy codes.

Insulation

N.

Galvalume® R-Type panel roof sheets are 3' wide and attach to the structure using Zac head screws for secure placement.

Galvalume® R-Type Panel

O.

3/4" vinyl-faced insulation is recommended to prevent condensation on the roof. The insulation is installed using fender washers. Fender Washer

N.

Insulation

Page 6: BUtler self-storageglcbuilt.com/.../butler-self-storage-design-specs-2015.pdf · 2017. 3. 30. · BUTLER® SELF-STORAGE DESIGN AND SPECIFICATION GUIDE - LOW PITCH ROOFS In insulated

BUTLER® SELF-STORAGE DESIGN AND SPECIFICATION GUIDE - LOW PITCH ROOFS

The screws at the eave are located outside the building to prevent roof leaks. The eave trim covers the eave angle and roof screws for a clean, finished look. This feature is standard on all Butler buildings.

5.

Galvalume® R-Type Panel Roof

Eave Trim

O.

The standing seam roof need only be screwed down at the eave. This prevents having exposed screws across the roof sheets, minimizing the potential for roof leaks. Butler highly recommends the standing seam roof, which features 2’ wide snap together panels.

Standing Seam Roof

P.

The screws at the eave are located outside the building to prevent roof leaks. The eave trim covers the eave angle and roof screws for a clean, finished look. This feature is standard on all Butler buildings.

Standing Seam RoofP.

An installed Galvalume® R-Type panel roof with exposed fasteners.

Installed Galvalume® R-Type Panel Roof

O.

Eave Angle

Eave Angle

Eave Trim

Page 7: BUtler self-storageglcbuilt.com/.../butler-self-storage-design-specs-2015.pdf · 2017. 3. 30. · BUTLER® SELF-STORAGE DESIGN AND SPECIFICATION GUIDE - LOW PITCH ROOFS In insulated

BUTLER® SELF-STORAGE DESIGN AND SPECIFICATION GUIDE - LOW PITCH ROOFS

Butler can ship the standing seam roof panel in sections up to 50' wide, avoiding the need for a ridge cap or screws inside the building.

6.

Standing Seam Roof

P.

Flush Panel

R.

A bright white rigid-rib hallway panel is an optional less expensive cost alternative to the flush panel.

If the gap above the corridor is greater than 7", Butler supplies burglar bars to fill the gap.

Rigid-Rib Panel

S.

An interior corridor with flush headers has a fixed height with a gap between the corridor and purlin. The gap varies depending on the location of the corridor. • The lights should be centered in the hallway. • Material used to support the lights are by others.

Flush Header

Q.

Butler standard corridor uses a flush panel for all blank walls. This system gives a clean, finished look.

S.

Burglar Bar

Page 8: BUtler self-storageglcbuilt.com/.../butler-self-storage-design-specs-2015.pdf · 2017. 3. 30. · BUTLER® SELF-STORAGE DESIGN AND SPECIFICATION GUIDE - LOW PITCH ROOFS In insulated

BUTLER® SELF-STORAGE DESIGN AND SPECIFICATION GUIDE - LOW PITCH ROOFS

4' diamond plate corner guards are used to protect panels from cart damage.

12" wide kick plates are used to protect panels from cart damage.

7.

4' Diamond Plate Corner Guards

24 Gauge Flush Panel

U.

A soffit ceiling is recommended if using door alarms. This gives access to the alarms for maintenance purposes. Butler can supply a 2-T8 bulb lighting package which is recommended.

Soffit

X.

The 18 gauge flush recessed entry way is an ideal location for the HVAC unit. In addition, it gives customers a place to stage their goods during inclement weather.

Recessed Entry

Y.

A bright white flush ceiling covers all interior duct work and completely encloses the corridor, resulting in a clean, finished look. Lights can be installed directly to the ceiling panel.

Flush CeilingW.

Diamond Plate Kick Plate

V.

Page 9: BUtler self-storageglcbuilt.com/.../butler-self-storage-design-specs-2015.pdf · 2017. 3. 30. · BUTLER® SELF-STORAGE DESIGN AND SPECIFICATION GUIDE - LOW PITCH ROOFS In insulated

BUTLER® SELF-STORAGE DESIGN AND SPECIFICATION GUIDE - LOW PITCH ROOFS

Header draft stops are used to seal the top of the door to minimize dust, dirt, and blowing snow from entering the unit. Draft stops may be added to a proposal or may be purchased at a later date.

8.

Draft Stop

Space Guard Latch

Stainless steel latches may be purchased as an alternative to the Space Guard latch. Guardian II locks for the stainless steel latches may be purchased separately, these locks can be keyed alike or keyed separately. The inset photo shows our ADA compliant latch.*

Jamb brush seals attach to the side jamb to minimize dust, dirt, and blowing snow from entering the unit. Brush seals may be added to a proposal or they may be purchased at a later date.

Brush Seal

The Space Guard latch comes installed on all doors. The cylinder lock can be purchased separately, these locks can be keyed alike or keyed separately. The inset photo shows our ADA compliant latch.*

*ADA loop may not be approved in all areas.

Stainless Steel Latch

Page 10: BUtler self-storageglcbuilt.com/.../butler-self-storage-design-specs-2015.pdf · 2017. 3. 30. · BUTLER® SELF-STORAGE DESIGN AND SPECIFICATION GUIDE - LOW PITCH ROOFS In insulated

BUTLER® SELF-STORAGE

DESIGN AND SPECIFICATION GUIDE

Butler ManufacturingKansas City, MO816-968-3000

www.butlermfg.com

Butler Buildings CanadaBurlington, ON Canada905-332-7786

Galvalume® is a registered trademark of BIEC International Inc. Kynar 500® is a registered trademark of Arkema. Hylar 5000® is a registered trademark of Solvay Solexis. The ENERGY STAR name and the ENERGY STAR symbol are registered trademarks of the United States Environmental Protection Agency. Thermax™ is a trademark of The Dow Chemical Company. (“DOW”) or an affiliated company of DOW. LEED is a trademark of the U.S. Green Building Council. The USGBC logo is a registered trademark owned by the U.S. Green Building Council and is used by permission.

© 2015 BlueScope Buildings North America, Inc. All rights reserved.Butler Manufacturing™ is a division of BlueScope Buildings North America, Inc. Find your independent Butler Builder ® at www.butlerbuilder.com

Form No. 5541 5/15

RATEDPRODUCT