Building Inspection Division 221 N Elm Street, Denton, TX 76201
940-349-8360 * Fax 940-349-7208
Residential Alteration Permit Packet and Information Use for: Residential Remodels and Additions: Garages, Sheds, Patios, Cabana, Pergolas, Decks, Retaining Walls,
Foundation Repair, Window Replacement, Etc.
Residential Addition/Remodel Plans Application, details, reports, and engineering that should be submitted when applying for a building permit to remodel, renovate, or enlarge an existing residential structure
Site Plan (for additions only) o Drawn to scale o Dimensions (including dimensions
between structures)
o North arrow
o Easements and building set-back lines o Driveway location o Include all structures on site including:
accessory buildings, fences, sidewalks (include width), retaining walls, air
conditioning unit with screening, etc.
o Identify location of proposed addition
o Legal lot description and lot address o Include % of lot coverage by
impervious surface (area not landscaped)
Foundation Plan
o Show depth and thickness of foundation
and footings
o Show rebar size and spacing in
foundation and footings
o Show rebar size and spacing or welded
wire mesh in slab
o Foundations 400 S.F. or larger require an Engineer’s seal
o Foundation less than 400 S.F. shall
match size and depth of existing
foundation
Floor Plans
o Drawn to scale o Dimensions o Door and window sizes including
windows and doors to be removed or covered
o Rooms adjacent to addition o Room descriptions and ceiling heights o 20 min. or solid core door between
house and attached garage o Gypsum wallboard or sheetrock
separation between house and garage
Elevation Plans (for additions only)
o All sides of structure affected by the
addition, show all architectural features
– exterior finishes, windows, and doors
o Roofing finishes
o Roof pitch o Overhangs (including depth) o Floor elevations and over-all house
height
o Photos of existing structure
Electrical Plans, to include all new installation
of:
o Lights o Switches o Electrical panel location o Smoke detectors o Receptacles o Arc-fault protection in sleeping rooms o GFCI protected receptacles in garage,
bathrooms, kitchen counters, exterior locations
o Exhaust fans
o Meter base location o Furnace and air conditioning unit
location
Roof, Ceiling, & Floor Framing Plans, to
include all new:
o Rafter and joist sizes and lumber grade
or span chart
o Rafter and joist lay-outs o Beams and header sizes
Stairway Section (if applicable)
o Rise and run of stairs o Handrail and guardrail height o Baluster spacing o Headroom o 5/8” type x sheetrock on ceiling and
walls of storage area located under stairs
Wall Section
o Anchor bolt size, spacing and treated sill plate
o Wall stud spacing and wall top plates
o Exterior sheathing o Brick tie spacing and weephole spacing o Footing and slab o Exterior vapor retarder/house wrap o Interior wall finish o Siding o Joists size, spacing, and rim joist size o Rafter size and spacing o Roof type and felt type o Purlin size and brace spacing o Attic ventilation specifications and
soffit vent sizes and spacing
o Wall and ceiling insulation with R-
values
Braced Panel or Wind Bracing Plans
o Braced wall panel types and locations o Alternate braced wall panel design and
hardware and specifications
Energy Code Compliance
Use the following minimum requirements for R-
values, U-values, and SHGC
o Glazing = U-factor 0.350 or less
o Solar Heat Gain Coefficient = SHGC -
0.250 or less
o Attic Insulation = R-value 38 or more
o Cathedral Ceiling with no attic = R-
value 38 or more
o Wall Insulation = R-value 13 or more
o Floor Insulation = R-value 19 or more
o Slab Perimeter = R-value 0 or more
o Crawlspace Wall = R-value 10 or more
o Gas Furnace/AC = AFUE–.8/SEER–
13 or more
o Electric Heat pump/AC = HSPF–
10/SEER–14 or more
o Gas water heater = Energy Factor-.7 or
better
o Electric water heater = Energy Factor-.9 or
better
Required plans (2 copies), application, details, reports, and
engineering that should be submitted when applying for a
building permit to build a new accessory structure (over
120 SF) which may include: detached garage, shed, shop,
gazebo, cabana, detached carport, detached patio cover,
pergola, etc.
Residential Alteration Permit Application complete as much information as possible,
including owner’s name, builder’s name,
subcontractor information, etc.
o Available at Building Inspection Department front desk
o Available at
http://www.cityofdenton.com/home/showdocument?id=20088
Site Plan, includes:
o Drawn to scale
o Dimensions (including dimensions between structures)
o Drainage direction arrows o North arrow o Easements and building set-back lines o Driveway location including the
required 18’ x 18’ min. parking pad
o Include all structures on site
including: accessory buildings, fences, sidewalks (include width), retaining walls, air conditioning unit with screening, etc.
o Legal lot description and lot address
o Include % of lot covered by impervious surface such as patios, sidewalks,
driveways, concrete slabs, structures, etc.
o Show that accessory structure is
not located in the front or side
yards (see Denton Development
Code Sec. 35.12.4)
Foundation Plan
o For slab on grade applications:
provide foundation details such as: size, width, depth of footings, and reinforcement type and location
o For non-slab on grade applications:
show post hole size and depth and post anchoring information
o If floor area is over 400 sf, submit
an engineered foundation plan
New Residential Accessory
Structure
Pl
Floor Plans, includes:
o Drawn to scale
o Dimensions o Door and window sizes o Room descriptions and ceiling heights
Elevation Plans, includes:
o Roofing finishes
o Wall finishes o Roof pitch o Overhangs (including depth) o Floor elevations and over-all structure
height
o Show the accessory building is architecturally
compatible with primary structure or will be screened from
o Public rights of way and abutting properties.
(See Denton Development Code 35.12.4)
Electrical Plans, (if applicable) includes:
o Lights o Switches o Electrical panel location o Receptacles (outlets) o GFCI protected receptacles in garage,
Bathrooms, exterior locations (receptacle in exterior locations shall have weatherproof covers)
o Exhaust fans
o Meter base location o Furnace and air conditioning unit location
Roof, Ceiling, & Floor Framing Plans, includes:
o Rafter and joist sizes and lumber grade or
span chart
o Rafter, joist lay-outs, and sheathing type o Beams and header sizes o Post sizes and material type
Stairway Section, (if applicable) includes:
o Rise and run of stairs
o Handrail and guardrail height o Baluster spacing
o Headroom o 5/8” type x sheetrock on ceiling and walls if storage area under stairs
Wall Section, includes:
o Anchor bolt size, spacing and treated sill
plate
o Wall stud spacing and wall top plates o Exterior sheathing o Brick tie spacing and weep hole spacing
o Footing and slab
o Exterior vapor retarder/house wrap o Interior wall finish o Siding o Joists size, spacing, and rim joist size o Rafter size and spacing o Roof type and felt type o Purlin size and brace spacing o Attic ventilation specifications and soffit vent sizes and spacing
o Wall and ceiling insulation with R- values
Braced Panel or Wind Bracing Plans, includes:
O Braced wall panel types and locations O Alternate braced wall panel design,
hardware, and specifications
Energy Code Compliance Report (if conditioned
space) – (2 Copies) IC3 (http://ic3.tamu.edu/), REScheck
(http://www.energycodes.gov/rescheck), Energy Star,
RESNET NCTCOG version, etc.
O Pass the NCTCOG IECC version of IC3
by 4% or more
O Pass the 2012 International Energy
Conservation Code (IECC) requirements by 2% or more
O Energy Star is exempt from the 4% over
requirements
Window Replacement Plans
Floor Plan/Window Rating
O Window locations and sizes
O Window U-factor rating must be .350 or
lower
O Window SHGC shall be .250 or lower
Retaining Walls Plans
For walls retaining a sloped grade (all walls retaining a
sloped grade or surcharge require a permit) or walls
which are over 4’ tall that are retaining a level grade
(4’ tall measured from the bottom of the footing to the
top of the wall)
o Site Plan
o Drainage arrows
o All structures o Engineering specifications
Foundation and Footing Repair
plans o Site and Floor plan
o All structures
o Location of foundation repairs
o Engineering specifications
Residential Building Permit Application
221 N Elm Street * Denton, Texas 76201-4107
(940) 349-8360 * Fax (940) 349-7208
Bldg Permit #
Utility
Date:
All property must be properly platted, zoned and all required public improvements either installed or addressed with three-way contracts before a building permit may be issued. To ensure adequate review, the proper number of plans, site plans, and complete building application submittal
is required. Note that an engineer, when required by the Texas Engineering Practice Act, must seal plans.
New Single Family Townhouse Duplex Remodel Addition Accessory Structure
Sect
ion
1
Site Address: Project Value: $
Subdivision: Lot: Block: Zoning:
Description of Work: Plan #: No. of Stories: Number of Units:
A/C Area (sf) - 1st Flr: 2nd: 3rd: Other: No. of Bedrooms:
Total Building (sf): Remodel (sf): Garage (sf): Patio/Porch (sf): No. of Bathrooms:
Impervious (covered) Lot Area (sf): Use of Building: Lot Size (sf): (driveway, walks, patio, garage, etc.) Covered Area/Lot %:
n 2
Sect
ion
2
Contact or Applicant: Phone:
Address: City: State: Zip:
Applicant's Signature:
Sect
3
Property Owner: Phone: E-mail:
Address: City: State: Zip:
Please list General Contractor and all Sub-contractors that will perform work on this permit.
Sect
ion
4
Gen Contractor: Phone: E-mail:
Address: City: State: Zip: Registered w/ City
Elect Contractor: Phone: E-mail:
Address: City: State: Zip: Registered w/ City
Plumb Contractor: Phone: E-mail:
Address: City: State: Zip: Registered w/ City
Mech Contractor: Phone: E-mail:
Address: City: State: Zip: Registered w/ City
Energy Rater: Phone: E-mail:
Address: City: State: Zip: Registered w/ City
Driveway Approach and Sidewalk Contractor must also submit copy of $1,000.00 Bond
Contractor Approach & Walks: Phone: E-mail:
Address: City: State: Zip: Registered w/ City
This permit becomes null and void unless a City inspection is performed within six months from the date of issuance. The granting of
a permit does not presume to give authority to violate or cancel the provisions of any law or ordinances regulating construction. No inspection will be performed unless this permit is displayed on the jobsite and the City approved plans are available to the
inspector on the jobsite at the time of inspection. Applicant is responsible for all work done under this permit, and must follow all applicable codes.
Blank Page
“Dedicated to Quality Service” www.cityofdenton.com
City of Denton Residential Building Inspections & Miscellaneous Inspections List
Schedule an Inspection online at: htts://www3.cityofdenton.com/etrakit3/ Please contact our office at (940) 349-8360 if you do not have a Contractor I.D. number or you cannot
schedule the inspection on the E-Trakit system. To Cancel an inspection please call (940) 349-8360 or (940) 349-8375. If the scheduled inspection is not ready for inspection and is not canceled before the site inspector arrives, a re-inspection fee will be assessed to the inspection. Daily Inspections must be scheduled before 7:00AM to be completed the same day, inspections scheduled after 7:00AM will be scheduled for the next business day. Permit Packets and City Approved Plans must be onsite for all Inspections.
Residential Permit (New Homes) & Residential Alteration
Permits
20- Temporary Power Pole
02- Piers/Footings/Beams
13- Plumbing Rough- Underground plumbing- Water test on D.W.V.
system required
03- Foundation- A copy of the official form board survey must be onsite
for the inspection
08- Sidewalk- See permit comments for requirements
09- Approach- See permit comments for requirements
45- Exterior Sheathing- Before building wrap (Tyvek), Siding or masonry
is installed- Nailing pattern of sheathing
65- Braced Wall- Interior Wind bracing, hold downs, straps, 1x4 or
other installed for wind bracing
66- Brick ties/Lath/Stucco
43- Seconds- Framing, Plumbing, Electrical, Mechanical Rough-Ins, Poly
Seal, Gas Test, Water Test
42- Insulation- Energy Compliance with Insulation, Doors & Windows
40- Sheetrock- Before Tape/Bed/Corners- Garage, Under Stairs,
Showers/Tubs, Nail/Screw patterns
49- Temporary Utilities- Gas Meter & Electric Meter- Air Test on gas
pipe system required
23- Temp Power- Electric Meter only
17- Temp Gas- Gas Meter only- Air Test on gas pipe system required
69- Irrigation Final- Must be inspected & approved on irrigation permit
before Final Building inspection
44- Final- Exterior and Interior
Landscaping, Fence, Site Drainage, Termite Treatment Report, City of
Denton Blower Door/ Duct Blaster Report, Final Irrigation system
Approved and all other outstanding conditions complete.
Miscellaneous & Over the Counter Permits
Miscellaneous Permits
04- Framing- Wood or Steel Construction
05- Fireplace- Masonry, Firebox, Chimney, Etc.
08- Sidewalk
09- Approach
25- Private Storm Drains
35- Landscape
38- Window or Door Replacement- Verify Manufactures detail stickers
51- Sand/Lint Trap
53- Dumpster Enclosure Layout
54- Medical Gas Rough-In
55- Medical Gas Final- 3rd Party testing of complete system required
Plumbing Permits
33- Water Heater 32- Grease Trap- Water Test required 46- Gas Test- Air Test Required 14- Water Line- Air Test or Water connection required 15- Sewer- Water Test required 19- Final Plumbing 18- Final Gas
Electrical Permits
24- Service Update
20- Temporary Power Pole
21- Electrical Rough-In
22- Electrical Underground
26- Final Electrical
Mechanical Permits
34- Vent Hood
73- Grease Duct/Light- Light Test required
74- Grease Duct/Fire- Fire wrap install
28- Final Mechanical
Fence Permits
07- Layout/Fence Post- Before placement of concrete
31- Fence Final
Irrigation Permits
13- Plumbing Rough- Underground pipe before backfill
29- Backflow Preventer- 3rd Party Test report onsite for inspection,
Freeze protection installed for backflow device
69- Irrigation Final- Turn on system, verify zones, verify spray patterns
& Etc. City of Denton Final Checklist complete & signed
Swimming Pool
07- Layout- Verify setbacks
10- Belly Steel- Before gunite, verify drains, rebar & bonding
11- Deck &Electrical Bond
15- Sewer/P-Trap
46- Gas Test- Underground pipe inspection, Air Test required
44- Final Pool- Before plaster-Do not fill pool
Sign Permits
07- Layout- For Ground & Monument signs
02- Piers/Footing/Foundation- Before placement of concrete
22- Underground Electrical- If sign is illuminated & Etc.
06- Final Sign- Sign Survey of sign location onsite for Inspection