8/2/2019 Btl Usa(a b y z) Catalog
1/26
User's Guide
english
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S140/S147/KA _ _
-
8/2/2019 Btl Usa(a b y z) Catalog
2/26
www.balluff.com
-
8/2/2019 Btl Usa(a b y z) Catalog
3/26www.ballu .com 3english
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
Notes to the user1 5Scope1.1 5Symbols and conventions1.2 5Scope o delivery1.3 5
Approvals and markings1.4 5 Abbreviations1.5 5
Sa ety2 6Intended use2.1 6General sa ety notes or the position measuring system2.2 6Explanation o the warnings2.3 6Disposal2.4 6
Construction and unction3 7Construction3.1 7Function3.2 7LED display3.3 8
Installation and connection4 9Installation guidelines4.1 9Preparing or installation4.2 9Installing the transducer 14.3 0
Installation recommendation or hydraulic cylinders 14.3.1 0Electrical connection 14.4 1
Connector type S32 14.4.1 1Connector type S115 14.4.2 1
Connector type S140 14.4.3 1Connector type S147 14.4.4 2Cable connection KA_ _ 14.4.5 2
Shielding and cable routing 14.5 2
Startup 15 3Starting up the system 15.1 3Operating notes 15.2 3
SSI inter ace 16 4Principle 16.1 4Data ormats 16.2 5
Faulty SSI query 16.3 5Synchronous and asynchronous operation 16.4 6
Confguration using the Micropulse Confguration Tool (only or BTL7-S510(B)-...)7 17Micropulse Confguration Tool (so tware) 17.1 7Connecting the USB communication box 17.2 7Confguration options 17.3 7
Technical data 18 8 Accuracy 8.1 8 Ambient conditions 8.2 8Supply voltage (external) 18.3 8Output 18.4 9Dimensions, weights 18.5 9Update rate and clock requency 28.6 0
-
8/2/2019 Btl Usa(a b y z) Catalog
4/264 english
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
Accessories 9 1Magnets 29.1 1Mounting nut 29.2 1Connectors and cables 29.3 2USB communication box 29.4 2
Type code breakdown 210 3 Appendix 11 5
Converting units o length 211.1 5Product labels 211.2 5
-
8/2/2019 Btl Usa(a b y z) Catalog
5/26www.ballu .com 5english
Scope1.1 This guide describes the construction, unction and setupoptions or the BTL7 Micropulse Transducer with SSIinter ace. It applies to typesBTL7-S5_ _ (B)-M_ _ _ _ -A/B/Y/Z(8)-S32/S115/S140/S147/KA_ _ (see Ordering code on page 23 or page 24).
The guide is intended or quali ied technical personnel.Read this guide be ore installing and operating thetransducer.
Symbols and conventions1.2
Individual handling instructions are indicated by apreceding triangle.
Handling instruction 1
Handling sequences are numbered consecutively:Handling instruction 11.Handling instruction 22.
Note, tip This symbol indicates general notes.
Scope o delivery1.3
BTL7 transducerCondensed guide
The magnets are available in various modelsand must be ordered separately.
Approvals and markings1.4
UL approvalFile no.E227256
US Patent 5 923 164 The US patent was awarded in connection with thisproduct.
The CE Mark veri ies that our productsmeet the requirements o EU Directive2004/108/EC (EMC Directive).
The transducer meets the requirements o the ollowinggeneric standards:
EN 61000-6-1 (noise immunity)EN 61000-6-2 (noise immunity)EN 61000-6-3 (emission)EN 61000-6-4 (emission)
and the ollowing product standard:EN 61326-2-3
Emission tests:
RF emissionEN 55016-2-3 (industrial and residential areas)
Noise immunity tests:
Static electricity (ESD)EN 61000-4-2 Severity level 3
Electromagnetic ields (RFI)EN 61000-4-3 Severity level 3
Electrical ast transients (burst)EN 61000-4-4 Severity level 3
SurgeEN 61000-4-5 Severity level 2
Conducted inter erence induced byhigh- requency ieldsEN 61000-4-6 Severity level 3
Magnetic ieldsEN 61000-4-8 Severity level 4
More detailed in ormation on the guidelines,approvals, and standards is included in thedeclaration o con ormity.
Abbreviations1.5
SSI Synchronous Serial Inter ace
Notes to the user1
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
6/266 english
Intended use2.1 The BTL7 Micropulse Transducer, together with a machinecontroller (e.g. PLC), comprises a position measuringsystem. It is intended to be installed into a machine orsystem. Flawless unction in accordance with thespeci ications in the technical data is ensured only whenusing original BALLUFF accessories. Use o any othercomponents will void the warranty.
Opening the transducer or non-approved use are notpermitted and will result in the loss o warranty and liabilityclaims against the manu acturer.
General sa ety notes or the position2.2measuring system
Installation and startup may only be per ormed bytrained specialists with basic electrical knowledge.Specialists are those who can recognize possible hazardsand institute the appropriate sa ety measures due to theirpro essional training, knowledge, and experience, as wellas their understanding o the relevant regulationspertaining to the work to be done.
The operator is responsible or ensuring that local sa etyregulations are observed.In particular, the operator must take steps to ensure that a
de ect in the position measuring system will not result inhazards to persons or equipment.I de ects and unresolvable aults occur in the transducer,it should be taken out o service and secured againstunauthorized use.
Explanation o the warnings2.3 Always observe the warnings in these instructions and themeasures described to avoid hazards.
The warnings used here contain various signal words andare structured as ollows:
SIGNAL WORDHazard type and sourceConsequences i not complied with
Measures to avoid hazardsf
The individual signal words mean:
NOTICE!Identi ies a hazard that could damage or destroy theproduct .
DANGER The general warning symbol in conjunction with thesignal word DANGER identi ies a hazard which, i notavoided, will certainly result in death or seriousinjury .
Disposal2.4
Observe the national regulations or disposal.
Sa ety2
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
7/26www.ballu .com 7english
6.7
0.5 257111 25
60
D
1 G
454613.5
12.8
71 (74.5) 25
74.512.8
BTL7...KA
BTL7...S115 BTL7...S32/S147
1)
1) 2)
Fig. 3-1: BTL7...A/B/Y/Z(8)... transducer, construction and unction
Construction3.1
Electrical connection: The electrical connection is madevia a cable or a connector (see Ordering code on page 23or page 24).
BTL housing: Aluminum housing containing theprocessing electronics.
Mounting thread: The transducers with 10.2 mm havean additional thread at the end o the rod to support largernominal lengths. We recommend assembling thistransducer on the mounting thread:
BTL7--A/B: M181.5BTL7--Y/Z: 3/4"-16UNF
Magnet: De ines the position to be measured on thewaveguide. Magnets are available in various models andmust be ordered separately (see accessories on page 21).
Nominal length: De ines the available measuring range.Rods with various nominal lengths rom 25 mm to7620 mm are available depending on the version:
10.2 mm: Nominal length rom 25 mm to 7620 mm 8 mm: Nominal length rom 25 mm to 1016 mm
Damping zone: Area at the end o the rod that cannot beused or measurements, but which may be passed over.
Function3.2
The Micropulse Transducer contains the waveguide whichis protected by an outer stainless steel tube (rod). Amagnet is moved along the waveguide. This magnet isconnected to the system part whose position is to bedetermined.
The magnet de ines the position to be measured on thewaveguide.
An internally generated INIT pulse interacts with themagnetic ield o the magnet to generate a torsional wavein the waveguide which propagates at ultrasonic speed.
The component o the torsional wave which arrives at theend o the waveguide is absorbed in the damping zone toprevent re lection. The component o the torsional wavewhich arrives at the beginning o the waveguide isconverted by a coil into an electrical signal. The travel timeo the wave is used to calculate the position that is outputin antivalent orm as synchronous serial data (SSI) on theRS-422 inter ace. This is done with a high level o precisionand reproducibility within the measuring range indicated asthe nominal length.
In addition to the position output value, the ollowingunctions can be selected (only BTL7-S510(B)-...):
Di erential positionSpeed (with or without leading sign)Speed di erence
Construction and unction3
Nominal length =Measuring range
Mounting sur aceB: 30-1 mmZ: 2"-0.04"
Damping zone 1)
Magnet 2)
BTL7...B/Z... Thread size:B: M18x1.5Z: 3/4"-16UNF
Mounting sur ace A: 30-1 mm A-SA211: 2"-0.04" Y: 2"-0.04"
BTL7...A/Y... Thread size: A: M18x1.5 Y: 3/4"-16UNF
1) Unusable area2) Not included in scope o
delivery
Version D1 G
...-A/B/Y/Z-... 10.2 mm ThreadM4x4/6 deep
...-A8/B8/Y8/Z8-... 8 mm No thread
BTL7...S140
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
8/268 english
3 Construction and unction (continued)
LED display3.3LED 1 LED 2
Fig. 3-2: Position o the BTL7 LED displays
LED 1
Green Normal unctionMagnet is within the measuring range.
Flashingred
Measuring range le tMagnet is outside the measuring range.
Red ErrorNo magnet or magnet outside the limits.
LED 2
Green Synchronous operation 1)Internal measurement is synchronous to SSI query.
O Asynchronous operation 1)
Internal measurement is asynchronous to SSI query.
Red SSI communication error To or T m event has occurred
Flashinggreen
Programming modeOnly with BTL7-S510(B)-...
Note on con iguration(only BTL7-S510(B)-...)
The entire range o unctionality can only becon igured with the PC so tware "MicropulseCon iguration Tool". To do this, the USBcommunication box must be connected (see
Accessories on page 22).
When reading or writing data via the MicropulseCon iguration Tool, LED 2 lashes green to displayprogramming mode.
1) Asynchronous operation is reached when the external sampling rate is> A,max or < 62.5 Hz (only with BTL7-S5_ _B-...), see Technical data on
page 20, Fig. 8-1.
Behavior o LED 1 and the error value through the entirerange:
Pos
SSI
out
0
5 mm
2 21LED
Fig. 3-3: Behavior o LED 1 and error value BTL7 5 m
For resolutions 5 m, in the case o an error, bit 2 21 is set,there is no error bit or resolutions < 5 m.
Null point End point
Magnetmissing
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
9/26
-
8/2/2019 Btl Usa(a b y z) Catalog
10/2610 english
Installing the transducer4.3
NOTICE!Inter erence in unctionImproper installation can compromise the unction o thetransducer and result in increased wear.
The mounting sur ace o the transducer must makefull contact with the supporting sur ace.
The bore must be per ectly sealed (O-ring/ at seal).f
Make a mounting hole with thread (possibly withcountersink or the O-ring) acc. to Fig. 4-3 or Fig. 4-4.
Screw the transducer with mounting thread into themounting hole (max. torque 100 Nm).Install the magnet (accessories).
For nominal lengths > 500 mm: Tighten the outer rodat the end (only possible with 10.2 mm) or support it.
Suitable nuts or the mounting thread areavailable as accessories (see page 21).
Installation recommendation or hydraulic4.3.1cylinders
I you seal the hole with a lat seal, the max. operating
pressure will be reduced in accordance with the largerpressurized sur ace.I installing horizontally in a hydraulic cylinder (nominallengths > 500 mm), we recommend a ixing a slidingelement to protect the rod end rom wear.
Dimensioning o the detailed solutions is theresponsibility o the cylinder manu acturer.
The sliding element material must be suitable or theappropriate load case, medium used, and applicationtemperatures. E.g. Torlon, Te lon or bronze are all possiblematerials.
Fig. 4-5: Example 1, transducer installed with sliding element
The sliding element can be screwed on or bonded.Secure the screws so they cannot be loosened or lost.
Select a suitable adhesive.
Detailed view and top view o sliding elementFig. 4-6:
There must be a gap between the sliding element andpiston bore that is su iciently large or the hydraulic oil tolow through.
Options or ixing the magnet:Screws
Threaded ringPress ittingNotches (center punching)
I installed in a hydraulic cylinder, the magnetshould not make contact with the outer rod.
The hole in the spacer ring must ensure optimum guidanceo the outer rod by the sliding element.
Fig. 4-7: Fixing o magnet
An example o how to install the transducer with asupporting rod is shown in Fig. 4-8 on page 11.
4 Installation and connection (continued)
Slide element
Magnet
Piston rodBTL outer rod
Slide element
Flow gapSlide sur ace
MagnetFixing o magnet
Spacer ring
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
11/26www.ballu .com 11english
Fig. 4-8: Example 2, transducer installed with supporting rod
Electrical connection4.4Depending on the model, the electrical connection is madeusing a cable or a connector.
The connection or pin assignments or the respectiveversion can be ound in Tables 4-2 to 4-6.
Note the in ormation on shielding and cablerouting on page 12.
Connector type S324.4.1
BTL7 standard BTL7 USBcon igurable
Pin BTL7-S5_ _-...-S32BTL7-S5_ _B-...-S32
BTL7-S510-...-S32BTL7-S510B-...-S32
1 CLK+ CLK+
2 DATA+ DATA+
3 CLK - CLK-
4 Not used 1) La2)
5 DATA- DATA -
6 GND GND
7 10 to 30 V 10 to 30 V
8 Not used 1) Lb2)1) Unassigned leads can be connected to the GND on the controller side
but not to the shield.2) Communication line
Connection assignment BTL7...-S32 Tab. 4-2:
Fig. 4-9: Pin assignment o S32 (view o connector pins o transducer), 8-pin M16 circular plug
Connector type S1154.4.2BTL7 standard BTL7 USB
con igurable
Pin BTL7-S5_ _-...-S115BTL7-S5_ _B-...-S115
BTL7-S510-...-S115BTL7-S510B-...-S115
1 CLK+ CLK+
2 DATA+ DATA+
3 CLK - CLK-
4 Not used 1) La2)
5 DATA- DATA -
6 GND GND
7 10 to 30 V 10 to 30 V8 Not used 1) Lb2)
1) Unassigned leads can be connected to the GND on the controller side
but not to the shield.2) Communication line
Connection assignment BTL7...-S115 Tab. 4-3:
Fig. 4-10: Pin assignment o S115 (view o connector pins o transducer), 8-pin M12 circular plug
Connector type S1404.4.3
BTL7 standard BTL7 USBcon igurable
Pin BTL7-S5_ _-...-S140BTL7-S5_ _B-...-S140
BTL7-S510-...-S140BTL7-S510B-...-S140
A DATA+ DATA+
B CLK+ CLK+
C CLK - CLK-
D 10 to 30 V 10 to 30 V
E Not used 1) Not used 1)
F GND GND
G Not used 1) La2)
H Not used 1) Lb2)
J DATA- DATA -
K Not used 1) Not used 1)1) Unassigned leads can be connected to the GND on the controller side
but not to the shield.2) Communication line
Connection assignment BTL7...-S140 Tab. 4-4:
A
BC
J
K
G
HF
D
E
Fig. 4-11: Pin assignment o S140 (view o connector pins o transducer), 10-pin circular plug
4 Installation and connection (continued)
Magnet(e.g. BTL-P-1028-15R)
Supporting rod made o non-magnetizable material
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
12/2612 english
Connector type S1474.4.4
BTL7 standard
Pin BTL7-S5_ _-...-S147BTL7-S5_ _B-...-S147
1 DATA-
2 DATA+
3 CLK+
4 CLK -
5 10 to 30 V
6 GND
7 Not used 1)1) Unassigned leads can be connected to the GND on the controller side
but not to the shield.
Connection assignment BTL7...-S147 Tab. 4-5:
Fig. 4-12: Pin assignment o S147 (view o connector pins o transducer), 7-pin M16 circular plug
Cable connection KA_ _4.4.5
BTL7 standard BTL7 USBcon igurable
Cablecolor
BTL7-S5_ _-...-KABTL7-S5_ _B-...-KA
BTL7-S510-...-KABTL7-S510B-...-KA
YE yellow CLK+ CLK+
GY gray DATA+ DATA+
PK pink CLK - CLK-
RD red Not used 1) La2)
GN green DATA - DATA -
BU blue GND GND
BN brown 10 to 30 V 10 to 30 V
WH white Not used 1) Lb2)
1) Unassigned leads can be connected to the GND on the controller side
but not to the shield.2) Communication line
Connection assignment BTL7...-KA Tab. 4-6:
BTL7...KA
CLK+
CLK
DATA+
DATA
GND
+24 V
YE
PK
GY
GN
BU
BNEvaluation
or
controller
Fig. 4-13: Connection example or BTL7-S...-KA_ _ 24 V DC withevaluation/controller
CLK, DATA and supply are twisted in pairs (seeFig. 4-13).
Shielding and cable routing4.5
De ined ground! The transducer and the control cabinet must beat the same ground potential.
Shielding To ensure electromagnetic compatibility (EMC), observethe ollowing:
Connect the transducer and controller using a shieldedcable.Shielding: Copper ilament braided, at least 85%coverageConnector version: Shield is interally connected toconnector housing.Cable version: On the transducer side, the cableshielding is connected to the housing.Ground the cable shielding on the controller side(connect with the protective earth conductor).
Magnetic ields The position measuring system is a magnetostrictivesystem. It is important to maintain adequate distancebetween the transducer cylinder and strong, externalmagnetic ields.
Cable routingDo not route the cable between the transducer, controller,and power supply near high voltage cables (inductive straynoise is possible).
The cable must be routed tension- ree.
Bending radius or ixed cable The bending radius or a ixed cable must be at least ivetimes the cable diameter.
For notes on cable length, see Technical dataon page 20, Fig. 8-2.
4 Installation and connection (continued)
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
13/26www.ballu .com 13english
Startup5
Starting up the system5.1
DANGERUncontrolled system movementWhen starting up, i the position measuring system ispart o a closed loop system whose parameters have notyet been set, the system may per orm uncontrolledmovements. This could result in personal injury andequipment damage.
Startup must be per ormed only by trained technicalfpersonnel.Observe the sa ety instructions o the equipment orf
system manu acturer.
Check connections or tightness and correct polarity.1.Replace damaged connections.
Turn on the system.2.Check measured values and adjustable parameters3.and readjust the transducer, i necessary.
Check or the correct values at the null pointand end point, especially a ter replacing thetransducer or a ter repair by the manu acturer.
Operating notes5.2
Check the unction o the transducer and all associatedcomponents on a regular basis.
Take the position measuring system out o operationwhenever there is a mal unction.Secure the system against unauthorized use.
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
14/2614 english
SSI inter ace6
Principle6.1SSI stands or Synchronous Serial Inter ace and describesa digital synchronous inter ace with a di erential clock lineand a di erential data line.With the irst alling cycle edge, the data word to be outputis bu ered in the BTL7 to ensure data consistency. Dataoutput takes place with the irst rising cycle lank, i.e. thetransducer supplies a bit to the data line or each risingcycle edge. In doing so, the line capacities and delays o drivers t v when querying the data bits must be taken intoaccount in the controller.
The max. clock requency CLK is dependent on the cablelength (see Technical data on page 20, Fig. 8-2). The t mtime, also called mono lop time, is started with the lastalling edge and is output as the low level with the lastrising edge. The data line remains at low until the t m timehas elapsed. A terwards, the BTL7 is ready again toreceive the next clock package.
CLK
DATA
T CLK
tv tv
CLK
DATAMSB LSB
T CLK
1 2 3 4 5 n n+1
t m
SSIn
CLK
DATA
T A
TCLK = 1/ CLK SSI clock period, SSI clock requency T A = 1/ A Sampling period, sampling rate
n Number o bits to be transmitted (requires n+1 clock impulses)tm = 2 T CLK Time until the SSI inter ace is ready againtv = 150 ns Transmission delay times (measured with a 1 m cable)
With the BTL7, position data is determined and output in atimely manner and synchronous to the external samplingperiod. For synchronous operation, the sampling period T A must be in the range T A,min T A 16 ms. The BTL7switches to asynchronous operation outside o this range.I the minimum sampling time is undercut, the BTL7outputs the same position value several times. Theexternal sampling rate is then greater than the internal rate.In addition, T A must be long enough so that the next clockpackage does not occur in the t m range o the previouspackage.
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
15/26www.ballu .com 15english
6 SSI inter ace (continued)
Data ormats6.2Standard BTL7 has the ollowing actory settings orposition output, which can no longer be changedretroactively:
SSI24, SSI25 or SSI26Binary or gray codedRising or alling
The contents o the in ormation to be t rans erred and theerror value can be con igured with the BTL7-S510(B)-.Position, speed, or position/speed di erences can be sentvia DATA. The MSB is always transmitted irst.
23 Position 0
M L
Output o a position via SSI24M = MSB (Most Signi icant Bit)L = LSB (Least Signi icant Bit)
252423222120 Error value or position value 0
0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Example o a SSI26 with error bit at bit position 21 anderror value 0. The data length there is 21 bit, the total bitnumber is 26. Four zeros are transmitted be ore the errorbit.
CLK
DATA15
1 2 3 4 5
SSI16
14 13 12
6 7 8 9 10 11 12 13 14 15 16 17
11 10 9 8 7 6 5 4 3 2 1 0
MSB LSB
Example o a complete SSI16 data transmissionFig. 6-1:
Depending on the con iguration, position or speed datamay have a leading sign with the BTL7-S510(B)-.Negative values are output as a two's complement. Withpositive speeds, the magnet moves away rom theelectronics head; with negative speeds it moves towardsthe electronics head. The controller must be set to processsigned data then.
Faulty SSI query6.3
UnderclockingI there are too ew clock edges, the current data level willbe maintained or the time t o (to = 2 T CLK Timeout times)a ter the last negative edge rom CLK. I , however, anotherpositive edge occurs, the next bit will then be output.
A terwards, a T o event will occur internally, the data outputswitches to low and then back to high a ter the time t m haselapsed. The high level is maintained until the next clockburst. Time t m starts a ter the end o time t o.
OverclockingI there are too many clock edges, the data output willswitch to low a ter the correct number o cycles has beencompleted. The t m timer is started again or everyadditional negative edge rom CLK and the T m event is setinternally. DATA switches back to high a ter the time t m haselapsed.
A To or T m event is displayed in the status ield as a com-munication error in the Micropulse Con iguration Tool. Inshort, a communication error is caused by the ollowing:
The bit number set in the BTL7 does not correspond to the bit number in the controller.nBTL > n PLC To event
nBTL < n PLC Tm event
The SSI clock requency is too low CLK < 9.771 kHz To event
The pause between two clock packages is too shortTm event
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
16/2616 english
6 SSI inter ace (continued)
Synchronous and asynchronous operation6.4Synchronous operation
A uni orm and brie timing is o ten required or controlapplications. The position delay t D must be kept as shortand constant as possible. Synchronous operation is thusintended or closed control loops. Here, the internalsensing cycle adjusts itsel to the external sampling cycle.
The ollowing graphic clari ies this relationship:
Two boundary conditions must be taken into accountduring synchronous operation: The external sampling requency A must be in the range62.5 Hz < A < A,max . The maximum permissible samplingrequency A,max is shown in Fig. 8-1 on page 20.
The sampling requency must be kept as constant aspossible.
The sampling requency is the reciprocal valueo the time between two clock packages andmay not be con used with the SSI clockrequency.
Asynchronous operationDuring asynchronous operation, the external samplingrequency is independent o the internal samplingrequency o the transducer. Depending on the externalquery point, the position is more or less current and theposition delay t D is not constant. In the worst case, it isequal to the internal sampling period. The transduceralways works with the maximum possible internal samplingrequency. Due to the measuring principle, the maximumsampling requency A,max is dependent on the nominallength o the transducer.
The ollowing graphic shows the behavior o internal andexternal sampling in asynchronous operation:
CLK
DATA
External samplingpoint
New value available
Internal samplingpoint + processing
Position delay
CLK
DATA
Externalsampling point
New value available
Internal samplingpoint + processing
Position delay
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
17/26www.ballu .com 17english
Confguration using the Micropulse Confguration Tool (only or BTL7-S510(B)-...)7
Micropulse Confguration Tool (so tware)7.1 The BTL7-S510(B)- transducer can be con iguredquickly and simply on a PC using the MicropulseCon iguration Tool PC so tware.
The most important eatures include:Online display o the current position o the magnetGraphic support or setting the unctions andcharacteristicsDisplay o in ormation on the connected transducerSelection o displayed number ormats and unitsPossible to reset to the actory settingsDemo mode without a connected transducer
The PC so tware and associated manual canbe ound in the Internet underwww.ballu .com/downloads-btl7.
Connecting the USB communication box7.2
With BTL7-S510(B)- transducers with a connector (S32/ S115/S140), the communication box must be looped inbetween the transducer and controller. The communicationbox is connected to the PC via a USB cable.
Fig. 7-1: Connecting the communication box with connector
With a BTL7-S510(B)--KA_ _ transducer, thecommunication lines La and Lb are connected to the USBcommunication box.
Fig. 7-2: Connecting the communication box with a cable connection
Confguration options7.3Prerequisites
USB communication box connected to the transducerand PC.So tware correctly installed.
Transducer connected to the power supply.Magnet on transducer.
Output unctionsPosition: Position in the measuring range.Speed: Speed o the magnet; the sign indicates thedirection o movement. A movement rom the startingpoint to end point is output with a positive sign; amovement rom the end point to the starting point is
output with a negative sign.Speed (unsigned): Speed o the magnet, the directiono movement cannot be read.Di erential position: Distance between two magnets.Selection is only possible i two magnets have beenselected.Speed di erence: The speeds o two magnets aresubtracted to orm a sum. Selection is only possible i two magnets have been selected.
Freely con igurable characteristic curve The gradient o the characteristic curve can be set byadjusting the resolution.
The characteristic curve can be inverted. The limits can be adjusted to the measuring range. The error value can be set.
Boundary conditions or several magnets Two magnets can only be selected rom a nominallength 90 mm.
The distance between two magnets must be 65 mm.
DANGERUncontrolled system movementWhen starting up, i the position measuring system ispart o a closed loop system whose parameters have not
yet been set, the system may per orm uncontrolledmovements. This could result in personal injury andequipment damage.
The system must be taken out o operation be orefconfguration.
Transducers may only bef connected to thecommunication box or confguration.
Thef communication box must be removed a tercon iguration.
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
18/2618 english
Accuracy8.1 The speci ications are typical values or BTL7-S... at24 V DC, at room temperature, and with a nominal lengtho 500 mm in conjunction with the BTL-P-1013-4R,BTL-P-1013-4S, BTL-P-1012-4R, BTL-P-1014-2R orBTL-P-0814-GR-PAF magnet.
The BTL is ully operational immediately, with ull accuracya ter warm-up.
For special versions, other technical data mayapply.Special versions are indicated by the su ix -SAon the part label.
Position resolution 1, 2, 5, 10, 20, 40, 50, 100 m(200, 500, 1000 m withBTL7-S510(B)-)
Linearity 30 m with a resolution 10 m 2 LSB with a resolution > 10 mNominal length 25 to 5500 mm
500 mNominal length 5501 to 7620 mm
Hysteresis 20 m
Repeat accuracy(6 )
11 m
Reproducibility(6 )
22 m
Temperaturecoe icient 1)
15 ppm/K
Speed resolution 0.1 mm/s
Min. detectablespeed
0.1 mm/s
Max. detectablespeed
10 m/s
1) Nominal length 500 mm, magnet in the middle o the measuring range
Ambient conditions8.2Operating temperature 40C to +85C
Storage temperature 40C to +100C
Relative humidity < 90%, non-condensing
Outer rod pressure rating(when installed in hydrauliccylinders)
For 8 mm < 250 barFor 10.2 mm < 600 bar
Shock ratingper EN 60068-2-27 2)
150 g/6 ms
Continuous shockper EN 60068-2-29 2) 150 g/2 ms
Vibrationper EN 60068-2-6 2)
20 g, 10 to 2000 Hz
Degree o protection perIEC 60529
Connector S32/S115/ S147 (when attached)
IP67
Connector S140 (whenattached)
IP65
Cable KA_ _ IP68 2)2) Individual speci ications as per Ballu actory standard
Supply voltage (external)8.3
Voltage, stabilized 10 to 30 V DC
Ripple 0.5 V ssCurrent draw (at 24 V DC) < 120 mA
Inrush current < 500 mA
Reverse polarity protection Up to 36 V(supply to GND)
Overvoltage protection Up to 36 V
Dielectric strength(GND to housing)
500 V DC
Technical data8
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
19/26www.ballu .com 19english
Output8.4Con igurable bit number(only BTL7-S510(B)-...)
16-32
Coding Binary or gray
Characteristic Rising or alling
SSI data Position, speed, absolutespeed, di erential position,speed di erence (between2 magnets), error value
SSI clock requency CLK 10 kHz to 1 MHz
Behavior at null point BTL7 standard:
No negative values betweenlange and null point
BTL7-S510(B)-...:Con igurable
Short-circuit protection Signal lines DATA + / - , CLK + / - ,La/Lb to +36 V or GND
8 Technical data (continued)
Dimensions, weights8.5Diameter o outer rod 8 mm or 10.2 mm
Nominal lengthFor 8 mm 25 to 1016 mmFor 10.2 mm 25 to 7620 mm
Weight (depends onlength)
Approx. 2 kg/m
Housing material Anodized aluminum
Outer rod material Stainless steel 1.4571
Outer rod wall thicknessFor 8 mm 0.9 mm
For 10.2 mm 2 mm Young's modulus Approx. 200 kN/mm 2
Housing mounting viathreads
M181.5 or 3/4"-16UNF
Tightening torque Max. 100 Nm
Cable diameter 1) 6.7 mm
Permissible cablebending radius 1)
Fixed routing 35 mmMovable 105 mm
1) For BTL7-...-KA_ _
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
20/2620 english
Update rate and clock requency8.6 The maximum sampling requency A,max , at which a newcurrent value is available with each sampling, can be oundin the ollowing graphic:
The maximum SSI clock requency CLK,max is dependent onthe cable length:
8 Technical data (continued)
A,max in Hz
Nominal length in mm
Cable length in m
CLK,max in kHz
Maximum sampling rate depending on the nominal length ( or position output)Fig. 8-1:
Maximum SSI clock requency depending on the cable lengthFig. 8-2:
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
21/26www.ballu .com 21english
Accessories are not included in the scope o delivery andmust be ordered separately.
Magnets9.1
BTL-P-1013-4R
BTL-P-1013-4S
BTL-P-1012-4R
BTL-P-1014-2R
BTL-P-0814-GR-PAF
Fig. 9-1: Magnet installation dimensions
BTL-P-1013-4R, BTL-P-1013-4S, BTL-P-1012-4R,BTL-P-1014-2R:
Weight: Approx. 10 g
Housing: Anodized aluminum
BTL-P-0814-GR-PAF:
Weight: Approx. 2 g
Housing: Ferrite bound in PA
The scope o delivery or BTL-P-1013-4R,BTL-P-1013-4S, BTL-P-1012-4R magnets includes:
Spacer: 8 mm, material: polyoxymethylene(POM)
BTL5-P-4500-1 magnet (solenoid):
Weight: Approx. 90 g
Housing: Plastic
Operatingtemperature:
- 40C to + 60C
BTL-P-1028-15R (special accessories orapplications with a supporting rod):
Weight: Approx. 68 g
Housing: Anodized aluminum
4.3
120
2
8
5
4
6
5
8
Mounting nut9.2
Mounting nut M181.5:BTL-A-FK01-E-M181.5
3/4-16UNF mounting nut:BTL-A-FK01-E-3/4-16UNF
Accessories9
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
22/2622 english
Connectors and cables9.3
BKS-S32M-00Straight connector, ield attachableM16 per IEC 130-9, 8-pin
~ 62
Fig. 9-2: Connector type BKS-S32M-00
BKS-S33M-00 Angled connector, ield attachableM16 per IEC 130-9, 8-pin
18
31
37.2
20
6
-
8 ~ 54
Fig. 9-3: Connector type BKS-S33M-00
BKS-S115-PU-_ _Straight connector, molded-on cable, preassembledM12, 8-pin
Various cable lengths can be ordered, e.g.BKS-S115-PU-05: Cable length 5 m
43
1 3
. 5
M 1 2 x
1
Fig. 9-4: Connector type BKS-S115-PU-_ _
BKS-S116-PU-_ _ Angled connector, molded-on cable, preassembledM12, 8-pin
Various cable lengths can be ordered, e.g.BKS-S116-PU-05: Cable length 5 m
2 8
M12x1
Fig. 9-5: Connector type BKS-S116-PU_ _
BKS-S140-23-00Straight connector, ield attachable10-pin
50
2
6
Fig. 9-6: Connector type BKS-S140-23-00
BKS-S147M-00Straight connector, ield attachable
M16 per IEC 130-9, 7-pin
~ 62
Fig. 9-7: Connector type BKS-S147M-00
BKS-S148M-00 Angled connector, ield attachableM16 per IEC 130-9, 7-pin
18
31
37.2
20
6
-
8 ~ 54
Fig. 9-8: Connector type BKS-S148M-00
USB communication box9.4
BTL7-A-CB01-USB-S32For BTL7-S510(B)-... with connector type S32.Scope o delivery: USB communication box, USB cable,2 adapter cables each approx. 0.3 m, condensed guide.
BTL7-A-CB01-USB-S115For BTL7-S510(B)-... with connector type S115.Scope o delivery: USB communication box, USB cable,2 adapter cables each approx. 0.3 m, condensed guide.
BTL7-A-CB01-USB-S140For BTL7-S510(B)-... with connector type S140.Scope o delivery: USB communication box, USB cable,2 adapter cables each approx. 0.3 m, condensed guide.
BTL7-A-CB01-USB-KAFor BTL7-S510(B)-... with cable connection.Scope o delivery: USB communication box, USB cable,1 adapter cable each approx. 0.6 m, condensed guide.
9 Accessories (continued)
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
23/26www.ballu .com 23english
Type code breakdown10BTL7 standard
BTL7 - S 5 0 1 B - M0500 - B - S32
Micropulse transducer
SSI inter ace
Supply voltage:
5 = 10 to 30 V DC
Data ormat:
24 bit 25 bit 26 bit
0 = Binary, rising 6 = Binary, rising A = Binary, rising
1 = Gray, rising 7 = Gray, rising B = Gray, rising
2 = Binary, alling 8 = Binary, alling C = Binary, alling
3 = Gray, alling 9 = Gray, alling D = Gray, alling
Resolution:
1 = 1 m 3 = 10 m 5 = 40 m 7 = 2 m
2 = 5 m 4 = 20 m 6 = 100 m 8 = 50 m
Synchronous/asynchronous operation:
B = synchronous operation
without B = asynchronous operation
Nominal stroke (4-digit):
M0500 = Metric speci ication in mm, nominal length 500 mm
Rod version, astening:
A = Metric mounting thread M18x1.5, rod diameter 10.2 mm
B = Metric mounting thread M18x1.5, O-ring, rod diameter 10.2 mm
Y = 3/4"-16UNF thread, rod diameter 10.2 mm
Z = 3/4"-16UNF thread, O-ring, rod diameter 10.2 mm
A8 = Metric mounting thread M18x1.5, rod diameter 8 mm
B8 = Metric mounting thread M18x1.5, O-ring, rod diameter 8 mm
Y8 = 3/4"-16UNF thread, rod diameter 8 mm
Z8 = 3/4"-16UNF thread, O-ring, rod diameter 8 mm
Electrical connection:
S32 = 8-pin, M16 plug per IEC 130-9
S115 = 8-pin, M12 plug
S140 = 10-pin, plug
S147 = 7-pin, M16 plug acc. to DIN 45329 (only with A or Y lange)
KA05 = Cable, 5 m
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
24/2624 english
10 Type code breakdown (continued)
BTL7 USB con igurable
BTL7 - S 5 1 0 B - M0500 - B - S32
Micropulse transducer
SSI inter ace
Supply voltage:
5 = 10 to 30 V DC
Data ormat:
1 = 24 bit, gray, rising ( actory setting)
Resolution:
0 = 1 m ( actory setting)
Synchronous/asynchronous operation:
B = synchronous operation
without B = asynchronous operation
Nominal stroke (4-digit):
M0500 = Metric speci ication in mm, nominal length 500 mm
Rod version, astening:
A = Metric mounting thread M18x1.5, rod diameter 10.2 mm
B = Metric mounting thread M18x1.5, O-ring, rod diameter 10.2 mm
Y = 3/4"-16UNF thread, rod diameter 10.2 mm
Z = 3/4"-16UNF thread, O-ring, rod diameter 10.2 mm
A8 = Metric mounting thread M18x1.5, rod diameter 8 mm
B8 = Metric mounting thread M18x1.5, O-ring, rod diameter 8 mm
Y8 = 3/4"-16UNF thread, rod diameter 8 mm
Z8 = 3/4"-16UNF thread, O-ring, rod diameter 8 mm
Electrical connection:
S32 = 8-pin, M16 plug per IEC 130-9
S115 = 8-pin, M12 plug
S140 = 10-pin, plug
KA05 = Cable, 5 m
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
25/26www.ballu .com 25english
Converting units o length11.1
1 mm = 0.0393700787 inch
mm inches
1 0.03937008
2 0.07874016
3 0.11811024
4 0.15748031
5 0.19685039
6 0.23622047
7 0.27559055
8 0.31496063
9 0.35433071
10 0.393700787
Conversion table mm to inches Tab. 11-1:
1 inch = 25.4 mm
inches mm
1 25.4
2 50.8
3 76.2
4 101.6
5 127
6 152.4
7 177.8
8 203.2
9 228.6
10 254
Conversion table inches to mm Tab. 11-2:
Product labels11.2
BTL7-S501-M0500-B-S32BTL0JCE
1 um / 24 bit / binary rising07112200054321 DE
Fig. 11-1: Standard BTL7 product label
BTL7-S510-M0500-B-S32BTL0AT4
1 um / 24 bit / Gray rising07112200054321 DE
USB-Configurable
Fig. 11-2: BTL7-S510-... product label
Appendix11
Ordering code
Type code
Serial number
Ordering code
Type code
Serial number
BTL7-S5_ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S147/KA _ _Micropulse Transducer - Rod Style
-
8/2/2019 Btl Usa(a b y z) Catalog
26/26
8 6 8 1 4 2 - 7 2 6 E
. 0 0
. 0 0 0 0 0 0
. E d i t i o n
0 9 1 2 ;
S u b j e c
t t o m o
d i f c a
t i o n .
www.balluff.com
Headquarters
GermanyBallu GmbHSchurwaldstrasse 973765 Neuhausen a.d.F.Phone + 49 7158 173-0Fax +49 7158 5010ballu @ballu .de
Global Service Center
GermanyBallu GmbHSchurwaldstrasse 973765 Neuhausen a.d.F.Phone +49 7158 173-370Fax +49 7158 173-691service@ballu .de
US Service Center
USABallu Inc.8125 Holton DriveFlorence, KY 41042Phone (859) 727-2200
Toll- ree 1-800-543-8390Fax (859) 727-4823