HM-5113 Brushless DC Motor and Driver Package BLV Series Standard Type, Electromagnetic Brake Type USER MANUAL Basic Function Thank you for purchasing an Oriental Motor product. This Operating Manual describes product handling procedures and safety precautions. Please read it thoroughly to ensure safe operation. Always keep the manual where it is readily available. Table of contents 1 Introduction ......................................... 2 2 Safety precautions .............................. 3 3 Precautions for use ............................. 5 4 System configuration .......................... 6 5 Preparation ......................................... 7 5.1 Checking the product .............................. 7 5.2 Combinations of motors and drivers ....... 7 5.3 Names and functions of parts.................. 8 6 Installation......................................... 10 6.1 Location for installation.......................... 10 6.2 Installation overview .............................. 10 6.3 Installing the combination type parallel shaft gearhead .......................... 11 6.4 Installing the round shaft type ............... 12 6.5 Installing the combination type hollow shaft flat gearhead ..................... 12 6.6 Installing a load to the combination type parallel gearhead or round shaft type ... 14 6.7 Installing a load to the combination type hollow shaft flat gearhead ..................... 15 6.8 Permissible overhung load and permissible thrust load .......................... 16 6.9 Installing the driver ................................ 17 6.10 Installing the external potentiometer (Accessory) ........................................... 18 6.11 Installing and wiring in compliance with EMC Directive ....................................... 19 7 Connection ........................................ 21 7.1 Connecting the power supply ................ 21 7.2 Connecting the motor and driver ........... 22 7.3 Connecting the I/O signals .................... 23 7.4 Connecting the communication cable ... 26 7.5 Connection diagram (Example) ............. 27 8 Operation .......................................... 28 8.1 Operation overview................................ 28 8.2 Basic operation ...................................... 29 8.3 Setting the acceleration time and deceleration time ................................... 31 8.4 Speed response selection ..................... 32 8.5 2-speed operation.................................. 32 8.6 Examples of operation patterns............. 33 8.7 Torque limiting function.......................... 33 8.8 Sink logic/Source logic selection ........... 34 8.9 Multi-motor control ................................. 35 9 Extended functions ........................... 37 9.1 Extended items ...................................... 37 10 Operation using a data setter OPX-2A............................................. 38 10.1 Setting the operation data ..................... 38 10.2 Multi-speed operation ............................ 38 10.3 Setting the operation input mode .......... 39 10.4 Analog setting/digital setting.................. 41 11 Inspection ......................................... 43 12 Protective function ............................ 44 13 Troubleshooting and remedial actions .............................................. 46 14 Accessories (Sold separately)........... 47

Transcript of Brushless DC Motor and Driver Package BLV Series

Page 1: Brushless DC Motor and Driver Package BLV Series

HM-5113

Brushless DC Motor and Driver Package

BLV Series Standard Type, Electromagnetic Brake Type USER MANUAL Basic Function

Thank you for purchasing an Oriental Motor product. This Operating Manual describes product handling procedures and safety precautions. • Please read it thoroughly to ensure safe operation. • Always keep the manual where it is readily available.

Table of contents 1 Introduction.........................................2 2 Safety precautions ..............................3 3 Precautions for use.............................5 4 System configuration ..........................6 5 Preparation .........................................7

5.1 Checking the product .............................. 7 5.2 Combinations of motors and drivers ....... 7 5.3 Names and functions of parts.................. 8

6 Installation.........................................10 6.1 Location for installation.......................... 10 6.2 Installation overview .............................. 10 6.3 Installing the combination type

parallel shaft gearhead.......................... 11 6.4 Installing the round shaft type ............... 12 6.5 Installing the combination type

hollow shaft flat gearhead ..................... 12 6.6 Installing a load to the combination type

parallel gearhead or round shaft type ... 14 6.7 Installing a load to the combination type

hollow shaft flat gearhead ..................... 15 6.8 Permissible overhung load and

permissible thrust load .......................... 16 6.9 Installing the driver ................................ 17 6.10 Installing the external potentiometer

(Accessory) ........................................... 18 6.11 Installing and wiring in compliance with

EMC Directive ....................................... 19

7 Connection........................................21 7.1 Connecting the power supply ................ 21 7.2 Connecting the motor and driver ........... 22 7.3 Connecting the I/O signals .................... 23 7.4 Connecting the communication cable ... 26 7.5 Connection diagram (Example)............. 27

8 Operation ..........................................28 8.1 Operation overview................................ 28 8.2 Basic operation...................................... 29 8.3 Setting the acceleration time and

deceleration time ................................... 31 8.4 Speed response selection ..................... 32 8.5 2-speed operation.................................. 32 8.6 Examples of operation patterns............. 33 8.7 Torque limiting function.......................... 33 8.8 Sink logic/Source logic selection ........... 34 8.9 Multi-motor control................................. 35

9 Extended functions ...........................37 9.1 Extended items...................................... 37

10 Operation using a data setter OPX-2A.............................................38 10.1 Setting the operation data ..................... 38 10.2 Multi-speed operation............................ 38 10.3 Setting the operation input mode .......... 39 10.4 Analog setting/digital setting.................. 41

11 Inspection .........................................43 12 Protective function ............................44 13 Troubleshooting and remedial

actions ..............................................46 14 Accessories (Sold separately)...........47

Page 2: Brushless DC Motor and Driver Package BLV Series

1 Introduction

−2−

1 Introduction

Before using the motor Only qualified personnel should work with the product. Use the product correctly after thoroughly reading the "2 Safety precautions" on p.3. The product described in this manual has been designed and manufactured for use in general industrial machinery, and must not be used for any other purpose. Oriental Motor Co., Ltd. is not responsible for any damage caused through failure to observe this warning.

Product overview The BLV Series is a motor and driver package combining a slim, high-power brushless motor with a high-performance box-type driver with DC power input. With the accessory data setter OPX-2A (sold separately), you can improve the performance and set operation data/parameters and motor operations with ease.

Operating manuals for the BLV Series Operating manuals for the BLV Series are listed below. Read the manuals carefully before using your BLV Series unit.

• BLV Series OPERATING MANUAL (Supplied with the product.) This manual explains the motor and driver functions as well as installation method, and others.

• BLV Series USER MANUAL Basic Function (This document) This manual explains the motor and driver functions, how to install/connect and troubleshooting, among others. Also, it explains operations using an accessory data setter OPX-2A.

• BLV Series USER MANUAL RS-485 Communication Mode This manual explains how to control the motor via RS-485 communication using a programmable controller.

CE Marking This product has been certified under the CE Marking requirements (EMC Directive) based on the EN Standard. Because the input power supply voltage of this product is 24 VDC/48 VDC, it is not subject to the Low Voltage Directive. However, install and connect this product as follows.

• Installation conditions Motor and driver are to be used as a component within other equipment. Overvoltage category: I Pollution degree: 2

• EMC Directive This product has received EMC compliance under the conditions specified in "Example of motor and driver installation and wiring" on p.20 The compliance of the final machinery with the EMC Directive will depend on such factors as the configuration, wiring, layout and risk involved in the control-system equipment and electrical parts.

Applicable Standards EMI Emission Tests EN 61000-6-4, EN 61800-3 C3EMS Immunity Tests EN 61000-6-2, EN 61800-3 C3

Hazardous substances RoHS (Directive 2002/95/EC 27Jan.2003) compliant

Page 3: Brushless DC Motor and Driver Package BLV Series

2 Safety precautions

−3−

2 Safety precautions The precautions described below are intended to prevent danger or injury to the user and other personnel through safe, correct use of the product. Use the product only after carefully reading and fully understanding these instructions.

Warning Handling the product without observing the instructions that accompany a "Warning" symbol may result in serious injury or death.

Caution Handling the product without observing the instructions that accompany a "Caution" symbol may result in injury or property damage.

NoteNote The items under this heading contain important handling instructions that the user should observe to ensure safe use of the product.

Warning

General • Do not use the product in explosive or corrosive environments, in the presence of flammable gases, locations

subjected to splashing water, or near combustibles. Failure to do so may result in fire, electric shock or injury. • Assign qualified personnel the task of installing, wiring, operating/controlling, inspecting and troubleshooting the

product. Failure to do so may result in fire, electric shock, injury or damage to equipment. • Do not use a non-electromagnetic brake type motor in a vertical application. If the driver protection function is

activated, the motor will stop and the moving part of the equipment will drop, thereby causing injury or equipment damage.

• Do not use the brake mechanism of the motor with an electromagnetic brake as a safety brake. It is intended to hold the movable parts and motor position. This caution is to avoid personal injury or damage to the equipment.

• When the driver's protection function is triggered, first remove the cause and then clear the protection function. Continuing the operation without removing the cause of the problem may cause malfunction of the motor and driver, leading to injury or damage to equipment.

Installation • Install the motor (gearhead) and driver in the enclosure in order to prevent injury.

Connection • Keep the driver's input-power voltage within the specified range to avoid fire. • For the power supply, use a DC power supply with reinforced insulation on its primary and secondary sides.

Failure to do so may cause electric shock. • Connect the cables securely according to the wiring diagram in order to prevent fire. • Do not forcibly bend, pull or pinch the cable. Doing so may cause fire. • Do not machine or modify the motor cable or extension cable. Doing so may result in fire. • Be sure to observe the specified cable sizes. Use of unspecified cable sizes may result in fire. • Observe the specified screw tightening torque when connecting terminals to the connector. Failure to do so may

result in fire or equipment damage.

Operation • Use a specified motor (gearhead) and driver combination. Failure to do so may result in fire or equipment damage.

Maintenance/inspection • Always turn off the power before performing maintenance/inspection. Failure to do so may result in injury. • Do not touch the motor or driver when measuring insulation resistance or performing a dielectric strength test.

Accidental contact may result in electric shock. • Regularly check the openings in the driver for accumulated dust. Accumulated dust may cause fire.

Repair, disassembly and modification • Do not disassemble or modify the motor (gearhead) and driver. This may cause electric shock or injury. Refer all

such internal inspections and repairs to the branch or sales office from which you purchased the product.

Page 4: Brushless DC Motor and Driver Package BLV Series

2 Safety precautions

−4−

Caution

General • Do not use the motor (gearhead) and driver beyond its specifications, or injury or damage to equipment may result. • Keep your fingers and objects out of the openings in the driver, or fire or injury may result. • Do not touch the motor (gearhead) and driver during operation or immediately after stopping. The surface is hot

and may cause a skin burn(s).

Installation • To prevent the risk of damage to equipment, leave nothing around the motor and driver that would obstruct

ventilation. • Do not hold the motor (gearhead) output shaft or cable. This may cause injury. • Do not touch the motor output shaft (key groove or pinion) with bare hands. Doing so may result in injury. • When assembling the motor with the gearhead, exercise caution not to pinch your fingers or other parts of your

body between the motor and gearhead. Injury may result. • Securely affix the motor (gearhead) and driver to their respective mounting plates. Inappropriate installation may

cause the motor/driver to detach and fall, resulting in injury or equipment damage. • Provide a cover over the rotating parts (output shaft) of the motor (gearhead) to prevent injury. • When installing the motor (gearhead) in the equipment, exercise caution not to pinch your fingers or other parts of

your body between the equipment and motor or gearhead. Injury may result. • Securely install the load on the motor (gearhead) output shaft. Inappropriate installation may result in injury.

Operation • Do not shut off the negative side of the power supply during operation. Also, note that the wiring for the power

supply does not disconnect. Doing so may cause damage to equipment. • Provide an emergency stop device or emergency stop circuit external to the equipment so that the entire equipment

will operate safely in the event of a system failure or malfunction. Failure to do so may result in injury. • Immediately when trouble has occurred, stop running and turn off the driver power. Failure to do so may result in

fire, electrical shock or injury. • Do not touch the rotating part (output shaft) during operation. This may cause injury. • The motor surface temperature may exceed 70 °C even under normal operating conditions. If the

operator is allowed to approach the running motor, attach a warning label as shown below in a conspicuous position. Failure to do so may result in skin burn(s).

Warning label

Disposal • To dispose of the motor (gearhead) and driver, disassemble it into parts and components as much as possible and

dispose of individual parts/components as industrial waste.

Page 5: Brushless DC Motor and Driver Package BLV Series

3 Precautions for use

−5−

3 Precautions for use This section covers limitations and requirements the user should consider when using the product.

• Regeneration energy When using the motor in operation such as vertical drive (gravitational operation) or sudden starting/stopping of a inertial load, regeneration energy may generate. Since the driver has no function to consume regeneration energy, if the output capacity or overvoltage allowance of the DC power supply is small, the protective function for the power supply or driver may activate and the motor may stop. When performing these operations, use a DC power supply or battery that has a large output capacity or overvoltage allowance. Also, use an electromagnetic brake motor not to drop the moving part in vertical drive (gravitational operation). If protective function for the power supply or driver is activated, contact your nearest Oriental Motor sales office.

• Do not use a solid-state relay (SSR) to turn on/off the power A circuit that turns on/off the power via a solid-state relay (SSR) may damage the motor and driver.

• Conduct the insulation resistance measurement or withstand voltage test separately on the motor and the driver. Conducting the insulation resistance measurement or withstand voltage test with the motor and driver connected may result in injury or damage to equipment.

• Grease measures On rare occasions, a small amount of grease may ooze out from the gearhead. If there is concern over possible environmental damage resulting from the leakage of grease, check for grease stains during regular inspections. Alternatively, install an oil pan or other device to prevent leakage from causing further damage. Oil leakage may lead to problems in the customer’s equipment or products.

• Apply grease to the output shaft of a hollow shaft flat gearhead If you are using a hollow shaft flat gearhead, apply grease (molybdenum disulfide grease, etc.) on the surface of the load shaft and inner walls of the hollow output shaft to prevent seizure.

• Preventing electrical noise Provide noise elimination measures to prevent a motor or driver malfunction caused by external noise. For more effective elimination of noise, use a shielded I/O signal cable or attach ferrite cores if a non-shielded cable is used. Refer to p.19 for the noise elimination measures.

• Note on connecting a power supply whose positive terminal is grounded The driver's main power supply input terminal (CN1), I/O signal connector (CN3), communication connector (CN5/CN6/CN7) and control power supply input terminal (TB1) are not electrically insulated. When grounding the positive terminal of the power supply, do not connect any equipment (PC, etc.) whose negative terminal is grounded. Doing so may cause the driver and these equipment to short, damaging both.

• The driver uses semiconductor elements. Handle the driver with care. The driver uses parts that are sensitive to electrostatic charge. Before touching the driver, turn off the power to prevent electrostatic charge from generating. If an electrostatic charge is impressed on the driver, the driver may be damaged.

• Use an extension cable (supplied) when extending the wiring distance between the motor and driver

Page 6: Brushless DC Motor and Driver Package BLV Series

4 System configuration

−6−

4 System configuration An example of system configuration using the BLV Series electromagnetic brake type is shown below.

Driver

Motor

Extension cable (Supplied)

Motor signal connector

Electromagnetic brake connector

Motor power connector

External control equipmentConnect I/O signals.

Power supplyMake sure power supplyvoltage does not exceedthe rated voltage.

External potentiometer

(Accessory)Connect this unit to set the motor speed externally.

External DC voltageConnect an appropriate power supplyto set the motor speed using DC voltage.

Or

Data setter OPX-2A

(Accessory)

RS-485 communication

Page 7: Brushless DC Motor and Driver Package BLV Series

5 Preparation

−7−

5 Preparation This chapter explains the items you should check, as well as the name and function of each part.

5.1 Checking the product Verify that the items listed below are included. Report any missing or damaged items to the branch or sales office from which you purchased the product. Verify the model number of the purchased unit against the number shown on the package label. Check the model number of the motor and driver against the number shown on the nameplate. The unit models and corresponding motor/driver combinations are listed in section 5.2.

• Motor (with a gearhead, only for combination type) ....................... 1 unit • Driver................................................................................................. 1 unit • Extension cable.................................................................................. 1 pc. • CN1 connector ................................................................................. 1 pc. • OPERATING MANUAL................................................................... 1 copy

Accessories for combination type • Hexagonal socket head screw set............1 set • Parallel key ...........................................1 pc. (Secured to the gearhead output shaft on the parallel shaft gearhead) • Safety cover ..........................................1 pc. (Supplied with the hollow shaft flat gearhead) • Safety cover mounting screw..................2 pcs. (Supplied with the hollow shaft flat gearhead)

5.2 Combinations of motors and drivers • in the model names indicates a number representing the gear ratio. • indicates a number representing the length of an extension cable. • The combination types come with the motor and gearhead pre-assembled.

Standard type

• Combination type parallel shaft gearhead Unit model Motor model Gearhead model Driver model

BLV620K S- BLVM620K-GFS BLVD20KM BLV640N S- BLVM640N-GFS

GFS6G BLVD40NM

• Combination type hollow shaft flat gearhead Unit model Motor model Gearhead model Driver model

BLV620K F- BLVM620K-GFS BLVD20KM BLV640N F- BLVM640N-GFS

GFS6G FR BLVD40NM

• Round shaft type Unit model Motor model Driver model

BLV620KA- BLVM620K-A BLVD20KM BLV640NA- BLVM640N-A BLVD40NM

Electromagnetic brake type

• Combination type parallel shaft gearhead Unit model Motor model Gearhead model Driver model

BLV620KM S- BLVM620KM-GFS BLVD20KM BLV640NM S- BLVM640NM-GFS

GFS6G BLVD40NM

• Combination type hollow shaft flat gearhead Unit model Motor model Gearhead model Driver model

BLV620KM F- BLVM620KM-GFS BLVD20KM BLV640NM F- BLVM640NM-GFS

GFS6G FR BLVD40NM

Page 8: Brushless DC Motor and Driver Package BLV Series

5 Preparation

−8−

• Round shaft type Unit model Motor model Driver model

BLV620KMA- BLVM620KM-A BLVD20KM BLV640NMA- BLVM640NM-A BLVD40NM

5.3 Names and functions of parts

Driver

Basic function switch [SW1]

I/O signal connector [CN4]

POWER LED (Green)

ALARM LED (Red)

C-DAT LED (Green)

C-ERR LED (Red)

Internal potentiometer [VR1]

Acceleration/deceleration time potentiometer [VR2]

Motor signal connector [CN3]

Motor power connector [CN2]

Main power supply input terminal [CN1]

Communication connector [CN7]

Electromagnetic brakeconnector [CN8]

RS-485 communicationconnector [CN5/CN6]

Control power supplyinput terminal [TB1]

Address number settingswitch [SW3]

Communication functionswitch [SW2]

Mounting hole (4 locations)

Torque limiting potentiometer [VR3]

Page 9: Brushless DC Motor and Driver Package BLV Series

5 Preparation

−9−

Name Description Ref.

POWER LED (Green) This LED lit while the main power or control power is input. −

ALARM LED (Red)

This LED will blink when an alarm generates (a protective function is triggered). You can check the generated alarm by counting the number of times the LED blinks.

P.44

Internal potentiometer [VR1] Set the operating speed of the motor. P.29 Acceleration/deceleration time potentiometer [VR2]

Set the acceleration time and deceleration time for the motor. P.31

Torque limiting potentiometer [VR3] Set the torque limiting value of the motor. P.33 Main power supply input terminal [CN1]

Connect the main power supply. BLV620: +24 V, BLV640: +48 V P.21

Motor power connector [CN2] Connect the motor power connector. Motor signal connector [CN3] Connect the motor signal connector. Electromagnetic brake connector [CN8]

Connect the electromagnetic brake connector. (Electromagnetic brake type only)

P.22

I/O signal connector [CN4] Use this connector when using an external control device (programmable controller) or inputting a operation command.

P.23

Basic function switches [SW1] Select type of speed response, external DC voltage and sink logic/source logic. P.29, P.32, P.34

Communication connector [CN7] Connect the OPX-2A. P.26 Control power supply input terminal∗ [TB1] Connect the driver control power supply.

RS-485 communication connector∗ [CN5/CN6] Connect the RS-485 communication cable.

C-DAT LED (Green) ∗ This LED will illuminate when the driver is communicating with the master station properly via RS-485 communication.

C-ERR LED (Red) ∗ This LED will illuminate when a RS-485 communication error occurs with the master station.

Communication function switch ∗ [SW2]

Set the baud rate, communication protocol and termination resistor of RS-485 communication.

Address number setting switch∗ [SW3]

This switch set the address number (slave address) of RS-485 communication.

Refer to the USER MANUAL RS-485 Communication Mode.

Mounting hole (4 locations) 4 locations on the back surface and side surface P.17 ∗ Use these switches when controlling the system via RS-485 communication.

Motor Illustration shows electromagnetic brake type.

Motor cable

Motor power cable

Motor signal cable

Electromagnetic brake connector

Pilot section

Motor

Electromagnetic brake

Output shaft

Mounting hole(4 locations)

Page 10: Brushless DC Motor and Driver Package BLV Series

6 Installation

−10−

6 Installation This chapter explains the installation location and installation methods of the motor and driver, as well as how to install a load and external potentiometer. The installation and wiring methods in compliance with the EMC Directive are also explained.

6.1 Location for installation The motor and driver are designed and manufactured for installation in equipment. Install them in a well-ventilated location that provides easy access for inspection. The location must also satisfy the following conditions:

• Inside an enclosure that is installed indoors (provide vent holes) • Operating ambient temperature Motor: 0 to +40 °C [+32 to 104 °F] (non-freezing)

Driver: 0 to +40 °C [+32 to 104 °F] (non-freezing) • Operating ambient humidity 85% or less (non-condensing) • Area not exposed to direct sun • Area free of excessive amount of dust, iron particles or the like • Area free of excessive salt • Area that is free of explosive atmosphere or toxic gas (such as sulfuric gas) or liquid • Area not subject to splashing water (rain, water droplets), oil (oil droplets) or other liquids • Area not subject to continuous vibration or excessive shocks • Area free of excessive electromagnetic noise (from welders, power machinery, etc.) • Area free of radioactive materials, magnetic fields or vacuum

6.2 Installation overview This section explains an overview of how to install the motor and driver. Refer to each applicable section for details.

Installing the combination type parallel shaft gearhead or round shaft type Install the hexagonal socket head screw in the four mounting holes you drilled and tighten the nuts until no gaps remain between the motor and mounting plate. The combination type parallel shaft gearheads come with a set of hexagonal socket head screws. Round shaft types do not come with hexagonal socket head screws and must be provided by the customer. Refer to p.11 and p.12 for the machining dimensions of the mounting plate and how to install/remove the gearhead.

Hexagonal socket head screw set (supplied)

• Combination type parallel shaft gearhead • Round shaft type

Hexagonal socket head screw

Hexagonal socket head screw set (supplied with the combination type parallel shaft gearhead)

Nominal size Tightening torque [N·m (lb-in)]

Maximum applicable plate thickness [mm (in.)].∗

M8 15.5 (137) 12 (0.47) ∗ When the supplied hexagonal socket head screw set is used.

Page 11: Brushless DC Motor and Driver Package BLV Series

6 Installation

−11−

Installing the combination type hollow shaft flat gearhead A combination type hollow shaft flat gearhead can be installed by using either its front or rear side as the mounting surface. Install the supplied hexagonal socket head screw set in the four mounting holes you drilled and tighten the nuts until no gaps remain between the motor and mounting plate.Also, attach the supplied safety cover to the hollow output shaft on the end opposite from the one where the load shaft is installed. Refer to p.12 for the installation method and how to install/remove the gearhead.

Front Mounting plate

Hollow-shaftflat gearhead

MotorRear

Hexagonal socket head screw set (supplied)

Nominal size Tightening torque [N·m (lb-in)]

Maximum applicable plate thickness [mm (in.)] ∗

M8 15.5 (137) 12 (0.47) ∗ When the supplied hexagonal socket head screw set is used.

Installing the driver The driver can be installed in two different ways. Refer to p.17 for the specific installation methods. • Use screws (M4: not supplied) to affix the driver through the mounting holes (two locations) provided at the back

of the driver. • Affix the driver on a DIN rail using the accessory DIN rail mounting plate (sold separately).

6.3 Installing the combination type parallel shaft gearhead Mounting hole dimensions [Unit: mm (in.)]

ØA ØB* C ØD 120 (4.72) 42 (1.65) 20 (0.79) 8.5 (0.335)

∗ B indicates the external dimensions of the product. Drill holes with a minimum diameter of ØB + 1 mm (0.04 in.).

ØBC

4×ØD

ØA

Removing/Installing the gearhead To replace the gearhead or change the cable outlet direction, remove the screws assembling the gearhead. The gearhead can be removed and the motor cable position changed to a desired 90° direction.

1. Remove the hexagonal socket head screws (2 pcs.) assembling the motor and gearhead and detach the motor from the gearhead.

2. Using the pilot sections of the motor and gearhead as guides, install the gearhead to the motor and tighten the hexagonal socket head screws. At this time, the motor cable position can be changed to a desired 90° direction. When installing the gearhead, slowly rotate it clockwise/counterclockwise to prevent the pinion of the motor output shaft from contacting the side panel or gear of the gearhead. Also confirm that no gaps remain between the motor flange surface and the end face of the gearhead’s pilot section.

Assembly screws

Nominal size Tightening torque [N·m (lb-in)]

M3 0.6 (5.3)

Hexagonal sockethead screw

Change the cableposition to a desired90° direction.

Page 12: Brushless DC Motor and Driver Package BLV Series

6 Installation

−12−

Note • Do not forcibly assemble the motor and gearhead. Also, do not let metal objects or other foreign matter enter the gearhead. The pinion or gear of the motor output shaft may be damaged, resulting in noise or shorter service life.

• Do not allow dust to attach to the pilot sections of the motor and gearhead. Also, assemble the motor and gearhead carefully by not pinching the O-ring at the motor’s pilot section. If the O-ring is crushed or severed, grease may leak from the gearhead.

• The hexagonal socket head screws assembling the motor and gearhead are affixing the motor and gearhead only temporarily. When installing the gearhead, be sure to use the supplied hexagonal socket head screws. (4 pcs.)

6.4 Installing the round shaft type Install the motor to a mounting plate of the following size or larger, so that the motor case temperature will not exceed 90 °C (194 °F).

Unit model Size of mounting plate [mm (in.)]

Thickness [mm (in.)] Material

BLV620 200×200 (7.87×7.87) 5 (0.2) BLV640 250×250 (9.84×9.84) 6 (0.24)

Aluminum

Mounting hole dimensions [Unit: mm (in.)] ØA B ØCH7∗ ØD

120 (4.72) 84.85 (3.341) 94+ 0.035 0

(3.7008+0.0014 0 ) 8.5 (0.335)

∗ ØC indicates the pilot diameter on the flange.

Note Fit the boss on the gearhead mounting surface into a pilot receiving hole.

ØCH7

B

B

ØA

ØD

6.5 Installing the combination type hollow shaft flat gearhead

Using the front side as the mounting surface When the gearhead is installed by using its front side as the mounting surface, use the boss of the output shaft to align the center.

• Mounting hole dimension

ØAØBH8

Safety cover

Hexagonal socket head screw

Safety covermounting screw

Page 13: Brushless DC Motor and Driver Package BLV Series

6 Installation

−13−

Using the rear side as the mounting surface

D

ØA ØC or more

• Mounting hole dimensionSafety cover

Hexagonal socket head screw

Safety covermounting screw

Mounting hole dimensions [Unit: mm (in.)] Since hexagonal nuts are not included with the product, provide them separately or drill tapped holes in the mounting plate.

ØA ØBH8 ØC D Nominal size

120 (4.72) 58+ 0.046 0

(2.28+0.0018 0 ) 42 (1.65) 57 (2.24) M8

Note When installing the gearhead by using its rear side, prevent contact between the mounting plate and motor by keeping dimension D below the specified value.

Removing/Installing the gearhead To replace the gearhead or change the cable outlet direction, remove the screws assembling the gearhead. The gearhead can be removed and the motor cable position changed to one of three 90° directions. Note that the motor cable cannot be positioned in the direction where the cable faces the gearhead output shaft.

1. Remove the hexagonal socket head screws (4 pcs.) attaching the gearhead and motor and detach the motor from the gearhead.

2. Using the pilot sections of the motor and gearhead as guides, install the motor to the gearhead and tighten the hexagonal socket head screws. At this time, the motor cable position can be changed to one of three 90° directions. Install the motor carefully to prevent the pinion of the motor output shaft from contacting the casing or gear of the gearhead. Also confirm that no gaps remain between the motor flange surface and the end face of the gearhead’s pilot section.

Assembly screws Nominal

size Tightening torque

[N·m (lb-in)] M8 15.5 (137)

Hexagonal sockethead screw

Change the cableposition to a desired90° direction.

Note • Do not forcibly assemble the motor and gearhead. Also, do not let metal objects or other foreign matter enter the gearhead. The pinion or gear of the motor output shaft may be damaged, resulting in noise or shorter service life.

• Do not allow dust to attach to the pilot sections of the motor and gearhead. Also, assemble the motor carefully by not pinching the O-ring at the motor’s pilot section. If the O-ring is pinched, the coupling strength will drop and grease may leak from the gearhead.

• The motor cable position cannot be changed to the direction where the cable faces the gearhead output shaft, because the gearhead case will obstruct the cable.

Page 14: Brushless DC Motor and Driver Package BLV Series

6 Installation

−14−

6.6 Installing a load to the combination type parallel gearhead or round shaft type

When installing a load on the motor (gearhead), align the center of the motor output shaft (gearhead output shaft) with the center of the load shaft.

Note • When coupling the motor (gearhead) with a load, pay attention to centering, belt tension, parallelism of pulleys, etc. Also, securely affix the tightening screws of the coupling or pulleys.

• When installing a load, do not damage the motor output shaft (gearhead output shaft) or bearing. Forcing in the load by driving it with a hammer, etc., may break the bearing. Do not apply any excessive force to the output shaft.

• Do not modify or machine the motor (gearhead) output shaft. The bearing may be damaged or motor (gearhead) may break.

Output shaft shape

• Combination type parallel shaft gearhead A key groove is provided on the output shaft of each combination type parallel shaft gearhead. Form a key groove on the load side and affix the load using the supplied parallel key.

• Round shaft type A flat section is provided on the motor output shaft of each round shaft type. Apply a double-point screw, etc., at the flat section to securely affix the load and prevent it from spinning.

How to install a load

• Using a coupling Align the centerline of the motor (gearhead) output shaft with the centerline of the load shaft.

• Using a belt Adjust the motor (gearhead) output shaft to lie parallel with the load shaft and form right angles between the output shaft/load shaft and the line connecting the centers of both pulleys.

• Using a gear Adjust the motor (gearhead) output shaft to lie parallel with the gear shaft and allow the output shaft to mesh correctly with the centers of the gear teeth.

• When using the output axis tip screw hole of a gearhead Use a screw hole [M6; Effective depth 12 mm (0.47 in)] provided at the tip of the output shaft as an auxiliary means for preventing the transfer mechanism from disengaging.

Fixed screw

Screw

Spacer

Transmission parts

Page 15: Brushless DC Motor and Driver Package BLV Series

6 Installation

−15−

6.7 Installing a load to the combination type hollow shaft flat gearhead If the motor is subject to a strong impact upon instantaneous stop or receives a large overhung load, use a stepped load shaft.

Note Apply grease (molybdenum disulfide grease, etc.) on the surface of the load shaft and inner walls of the hollow output shaft to prevent seizure.

Recommended load shaft installation dimensions [Unit: mm (in.)] Inner diameter of hollow shaft

(H8)

Recommended diameter of load shaft

(h7)

Nominal diameter of

retaining ring

Applicable screw

Spacer thickness

Outer diameter of stepped shaft

(ØD) Ø25+0.033

0 (0.9843+0.0013

0 ) Ø25 0

-0.021 (0.9843 0

-0.0008) Ø25 (0.98) M10 6 (0.24) 40 (1.57)

Stepped load shaft

• Affixing method using retaining ring Install each hexagonal socket head screw over a retaining ring, spacer, flat washer and spring washer and securely affix the ring.

Flat washer

Spacer

Retaining ring

Stepped load shaft

Parallel key

Spring washer

Hexagonal socket head screw

Retaining ring

Hollow output shaft

Hexagonal sockethead screw

Spring washer

Flat washer

SpacerParallel key

Stepped load shaft

ØD

• Affixing method using end plate Affix the load shaft by tightening the hexagonal socket head screw over an end plate, flat washer and spring washer.

Flat washer

End plate

Parallel key

Spring washer

Hexagonal socket head screw

Hollow output shaft

Hexagonal sockethead screw

Spring washer

Flat washer

End plateParallel key

Stepped load shaft

ØD

Stepped load shaft

Note The supplied safety cover cannot be installed because it interferes against the hexagonal socket head screws. The customer must provide other protective measure for the rotating part.

Page 16: Brushless DC Motor and Driver Package BLV Series

6 Installation

−16−

Non-stepped load shaft Install each hexagonal socket head screw over a retaining ring, spacer, flat washer and spring washer and securely affix the ring. Also insert a spacer on the load shaft side.

Flat washer

Spacer

Retaining ring

Load shaft

Parallel key

Spring washer

Hexagonal socket head screw

Retaining ring

Hollow output shaft

Hexagonal sockethead screw

Spring washer

Flat washer

SpacerSpacerParallel key

Load shaft

Spacer

6.8 Permissible overhung load and permissible thrust load Make sure the overhung load and thrust load received by the motor (gearhead) output shaft will not exceed the allowable values shown in the table below.

Note If the overhung load or thrust load exceeds the specified allowable value, repeated load applications may cause the bearing or output shaft of the motor (gearhead) to undergo a fatigue failure.

• Combination type parallel shaft gearhead Distance from tip of gearhead output shaft and permissible overhung load∗ [N (lb.)] Gear ratio 10 mm (0.39 in.) 20 mm (0.79 in.)

Permissible thrust load [N (lb.)]

5 to 20 550 (123) <500 (112)>

800 (180) <700 (157)> 200 (45)

30, 50 1000 (220) <900 (200)>

1250 (280) <1100 (240)> 300 (67)

100, 200 1400 (310) <1200 (270)>

1700 (380) <1400 (310)> 400 (90)

∗ The values assume a rated speed of 3000 r/min or below. The values in < > are based on a rated speed of 4000 r/min.

• Combination type hollow shaft flat gearhead Distance from gearhead mounting surface and permissible overhung load∗ [N (lb.)] Gear ratio 10 mm (0.39 in.) 20 mm (0.79 in.)

Permissible thrust load [N (lb.)]

5 (BLV640 only)10

1230 (270) <1130 (250)>

1070 (240) <990 (220)>

15, 20 1680 (370) <1550 (340)>

1470 (330) <1360 (300)>

30 to 100 2040 (450) <1900 (420)>

1780 (400) <1660 (370)>

800 (180)

∗ The values assume a rated speed of 3000 r/min or below. The values in < > are based on a rated speed of 4000 r/min.

• Round shaft type Distance from tip of motor output shaft and

permissible overhung load [N (lb.)] Permissible thrust load

[N (lb.)] 10 mm (0.39 in.) 20 mm (0.79 in.)

197 (44) 221 (49) Not to exceed one-half the

motor’s mass∗ ∗ Minimize the thrust load. If a thrust load must be applied, do not let it exceed one-half the motor’s mass.

Page 17: Brushless DC Motor and Driver Package BLV Series

6 Installation

−17−

6.9 Installing the driver The driver is designed so that heat is dissipated via air convection and conduction through the enclosure. Install the driver on a flat metal plate having excellent vibration resistance and heat conductivity. When two or more drivers are to be installed side by side, provide 20 mm (0.79 in.) and 25 mm (0.98 in.) clearances in the horizontal and vertical directions, respectively.

Note • Install the driver in an enclosure whose pollution degree is 2 or better environment, or whose degree of protection is IP54 minimum.

• Do not cover the radiation vent of the driver. • Do not install any equipment that generates a large amount of heat or noise near the driver. • If the ambient temperature of the driver exceeds 40 °C (104 °F), revise the ventilation condition

or force-cool the area around the driver using a fan.

Installing with screws Affix the driver through the mounting holes using two screws (M4: not supplied).

147

(5.7

9)

147

(5.7

9)

Ø4.5 (0.177) 2×Ø4.5 (0.177)

147 (5.79)

147 (5.79)

Ø4.5 (0.177)

2×Ø4.5 (0.177)

• When mounting in vertical direction [Unit: mm (in.)]

• When using side surface A

• When using side surface A

• When using side surface B

• When using side surface B

• When mounting in horizontal direction [Unit: mm (in.)]

BA

A

B

Page 18: Brushless DC Motor and Driver Package BLV Series

6 Installation

−18−

Mounting to DIN rail When mounting the driver to a DIN rail, use a separately sold DIN rail mounting plate (model number: PADP03) and attach it to a 35 mm (1.38 in.) wide DIN rail. After installation, fix the both sides of the driver with the end plate (not supplied).

DIN rail

DIN lever

Hook

DIN rail mounting plate

Mounting screw (supplied)Tightening torque: 0.3 to 0.4 N·m (2.6 to 3.5 lb-in)

Mounting hole(M3-4 locations)

Note • Do not use the mounting holes (M3, four locations) for the DIN rail mounting plate for any purpose other than securing the DIN rail mounting plate.

• Be sure to use the supplied screws when securing the DIN rail mounting plate. The use of screws that would penetrate 3 mm (0.12 in.) or more through the surface of the driver may cause damage to the driver.

• Removing from DIN rail Pull the DIN lever down until it locks using a flat tip screwdriver, and lift the bottom of the driver to remove it from the rail. Use force of about 10 to 20 N (2.2 to 4.5 lb.) to pull the DIN lever to lock it. Excessive force may damage the DIN lever.

DIN lever

6.10 Installing the external potentiometer (Accessory) 1. Insert the variable resistor over the insulation sheet into the hole provided in the mounting plate.

2. Set the dial plate and toothed washer, and tighten with the nut. Tightening torque: 0.45 N·m (3.9 lb-in)

3. Install the dial and secure it with the setscrew (M4). Tightening torque: 0.4 N·m (3.5 lb-in)

• Reference mounting hole dimensions [Unit: mm (in.)]

Ø3 (0.12)

7.5±0.4 (0.3±0.02)

Ø10 (0.39)

Dial

NutTightening torque:

0.45 N·m (3.9 lb-in)

Toothed washer

Dial plate

Mounting plate

Insulation sheet

Variable resistor

SetscrewTightening torque: 0.4 N·m (3.5 lb-in)

Page 19: Brushless DC Motor and Driver Package BLV Series

6 Installation

−19−

Soldering the variable resister terminals and the lead wires 1. Guide the lead wires through the terminal hole and loop them two to three times.

2. Solder the lead wires to the terminal. Soldering condition: 235 °C (455 °F), less than 5 sec.

3. Cover a heat-shrinkable tube over the soldered part to insulate.

DialVariable resistor

Dial plate

Mounting plate

Lead wire

Insulation sheet

Lead wire

TerminalHeat-shrinkable tube

Solder (after looping the leadwires two to three times).

6.11 Installing and wiring in compliance with EMC Directive The BLV Series is designed and manufactured for use as an internal component of equipment. The EMC Directives require that your mechanical equipment in which the BLV Series is installed satisfy the applicable requirements. The installation/wiring methods of the motor and driver explained here represent the basic methods that are effective in helping your mechanical equipment conform to the EMC Directives. The final level of conformance of your mechanical equipment to the EMC Directives will vary depending on the control system equipment used with the motor/driver, configuration of electrical parts, wiring, layout, hazard level, and the like. Therefore, you must conduct the EMC tests on your mechanical equipment to confirm compliance.

Applicable Standards EMI Emission Tests EN 61000-6-4, EN 61800-3 C3EMS Immunity Tests EN 61000-6-2, EN 61800-3 C3

Effective measures must be taken against the EMI that the BLV Series may give to adjacent control-system equipment, as well as the EMS of the BLV Series itself, in order to prevent a serious functional impediment in the machinery. The use of the following installation and wiring methods will enable the BLV Series to be compliant with the EMC Directive.

Connecting a mains filter • Install a mains filter in the power line in order to prevent the noise generated within the driver or control system

from propagating outside via the DC input line. • When using a power supply transformer, be sure to connect a noise filter to the AC input side of the power supply

transformer. • For a mains filter, use MC1210 (TDK-Lambda Corporation) or equivalent product. Install the mains filter as close

to the AC input terminal of DC power supply as possible. • Connect the ground terminal of the mains filter to the grounding point, using as thick and short a wire as possible. • Use a shielded cable of AWG18 to 14 (0.75 to 2.0 mm2) for the AC input cables and output cables.

Use cable clamps and other means to secure the AC input cables and output cables firmly to the surface of the enclosure.

• Do not place the AC input cable parallel with the mains filter output cable. Parallel placement will reduce mains filter effectiveness if the enclosure's internal noise is directly coupled to the power supply cable by means of stray capacitance.

Wiring the power supply cable and signal cable • Use a shielded cable of AWG16 to 10 (1.25 to 6 mm2) for the power supply cable, and keep it as short as possible. • Use a shielded cable for the I/O signals cable, and keep it as short as possible. • Strip a part of the shielded cable and ground the stripped part using

a metal cable clamp that contacts the stripped cable around its entire circumference, or use a drain wire to make the ground connection.

• Attach a cable clamp as close to the end of the cable as possible, and connect it as shown in the figure.

Cable clampShielded cable

Page 20: Brushless DC Motor and Driver Package BLV Series

6 Installation

−20−

Notes about installation and wiring • Connect the motor, driver and other peripheral control equipment directly to the grounding point so as to prevent a

potential difference from developing between grounds. • When relays or electromagnetic switches are used together with the system, use mains filters and CR circuits to

suppress surges generated by them. • Keep cables as short as possible without coiling and bundling extra lengths. • Wire the power lines such as the motor cable and power cable away from the signal cables by providing a

minimum clearance of 100 mm (3.94 in.) between them. If they have to cross, cross them at a right angle. Place the AC input cable and output cable of a mains filter separately from each other.

• Use a supplied extension cable when extending the wiring distance between the motor and driver. The EMC measures are conducted using the Oriental Motor extension cable.

Example of motor and driver installation and wiring

Driver

DC power supply

PE

Mains filter

PE

Motor

I/O signal cable [2 m (6.6 ft.)]

RS-485 communication cableExternal potentiometer

Cableclamp

OPX-2A

FG

FG

FG

Precautions about static electricity Static electricity may cause the driver to malfunction or suffer damage. While the driver is receiving power, handle the driver with care and do not come near or touch the driver. Always use an insulated screwdriver to adjust the driver's potentiometers or switches.

Note The driver uses parts that are sensitive to electrostatic charge. Before touching the driver, turn off the power to prevent electrostatic charge from generating. If an electrostatic charge is impressed on the driver, the driver may be damaged.

Page 21: Brushless DC Motor and Driver Package BLV Series

7 Connection

−21−

7 Connection This chapter explains how to connect the driver and motor, I/O signals, and power supply.

7.1 Connecting the power supply

Connecting method 1. Strip the insulation cover of the lead wire by 10 mm (0.39 in.)

Applicable lead wire: AWG16 to 10 (1.25 to 6 mm2)

2. Insert each lead wire into the CN1 connector and tighten the screw. Tightening torque: 0.7 to 0.8 N·m (6.1 to 7.0 lb-in)

3. Insert the CN1 connector into CN1.

10 mm (0.39 in.)

Lead wire

CN1 connector

CN1

Note • For the driver's power supply use a DC power supply with reinforced insulation on its primary and secondary sides.

• When connecting, check the indication of the driver case and pay attention to the polarity of the power supply. Reverse-polarity connection may cause damage to the driver.

• Do not wire the power supply cable of the driver in the same cable duct with other power line or motor cable. Doing so may cause malfunction due to noise.

• When cycling the power or plugging/unplugging the connector, turn off the power and wait for the POWER LED to turn off.

• When unplugging the CN1 connector, do so after pressing the lever (orange) on the CN1.

Applicable crimp terminal If crimp terminals are used, select the following terminals.

Manufacturer Model Applicable lead wire AI 1.5-10 AWG16 (1.25 mm2) AI 2.5-10 AWG14 (2 mm2) AI 4-10 AWG12 (3.5 mm2)

PHOENIX CONTACT GmbH & Co. KG

AI 6-10 AWG10 (6 mm2)

Recommended power supply capacity Unit model Input power supply voltage Current capacity

BLV620 24 VDC±10% 800 W or more BLV640 48 VDC±10% 1 kW or more

Page 22: Brushless DC Motor and Driver Package BLV Series

7 Connection

−22−

7.2 Connecting the motor and driver Connect the motor cable to the motor power connector (CN2) and motor signal connector (CN3) of the driver. When using a electromagnetic brake motor, also connect to the electromagnetic brake connector (CN8). To expand connection between the motor and driver, use the supplied extension cable. Connection can be extended to a maximum of 3.5 m (11.5 ft.).

Motor power connectorConnect to CN2.

Motor signal connectorConnect to CN3.

Extension cable (supplied) Motor cable

Electromagnetic brake connectorConnect to CN8∗

∗ Electromagnetic brake type only.

Note Ensure that the connector plugged in securely. Insecure connection may cause malfunction or damage to the motor or driver.

Connector of the motor cable

• Motor power connector Pin No. Lead color Lead size

1 Blue 2 Purple 3 Gray

AWG14 (2.0 mm2)

3

2

1

Housing: DF22CR-3S-7.92C (HIROSE ELECTRIC CO., LTD.) Terminal: DF22-1416SCFA (HIROSE ELECTRIC CO., LTD.)

• Motor signal connector Pin No. Lead color Lead size

1 Yellow 2 Green 3 Orange 4 Red 5 Brown

AWG24 (0.2 mm2)

54321

Housing: 51103-0500 (Molex) Terminal: 50351-8000 (Molex)

• Electromagnetic brake connector Pin No. Lead color Lead size

1 Black 2 White

AWG24 (0.2 mm2)

21

Housing: 51103-0200 (Molex) Terminal: 50351-8000 (Molex)

Page 23: Brushless DC Motor and Driver Package BLV Series

7 Connection

−23−

7.3 Connecting the I/O signals Connecting the I/O signals to the I/O connector (CN4). Keep the wiring distance as short as possible [less than 2 m (6.6 ft.)] to suppress the effect of noise.

Note • The connector for connecting the I/O signals is not included. Please prepare as follows; · D-Sub connector (15-pin) · Hood (the screw: No.4-40UNC)

• Wire the signal cable at a distance of 100 mm (3.94 in) or more from the inductive load (electromagnetic relay etc.), power supply or power cable (motor cable etc.).

Connector function table 18 27

915 1014

This figure is the CN4 connector viewed from the driver front side.

Pin No. Signal type Terminal name Signal name Description

1 X0∗1 FWD The motor turns in the clockwise direction. 2 X1∗1 REV The motor turns in the counterclockwise direction.3 X2∗1 STOP-MODE Select instantaneous stop or deceleration stop.

4

Input

X3∗1 M0 Select the internal potentiometer or external potentiometer (external DC voltage).

5 GND C0 IN-COM −

6 Y2 SPEED-OUT 30 pulses are output with each revolution of the motor output shaft.

7 Y1−∗1 WNG (−) − 8

Output

Y0−∗1 ALARM-OUT (−) − 9 X4∗1 ALARM-RESET Alarms are reset.

10 Input

X5∗1 MB-FREE∗2 Select how the electromagnetic brake would operate when the motor stops.

11 VL VL 12 VM VM 13

Analog input VH VH

External speed setting input Set the speed of the external potentiometer (external DC voltage).

14 Y1+∗1 WNG (+) This signal is output when a warning generates.

15 Output

Y0+∗1 ALARM-OUT (+) This signal is output when an alarm generates (normally closed).

∗1 The OPX-2A can be used to change the assignments of I/O signals. ∗2 Electromagnetic brake type only.

Input signals circuit All input signals of the driver are photocoupler inputs. When an external power supply is used: 24 VDC −15 to +20%, 100 mA or more +15 V

0 V

3.3 kΩ

Pin No. SW1-No.3

1 to 49, 10

5

Output signals circuit The driver outputs signals are photocoupler/open-collector output. The ON voltage of the output circuit is max. 1.5 V (0.5 V for SPEED-OUT output). When driving each element using the output signal circuit, give consideration to this ON voltage. BLV620: 30 VDC or less, 100 mA or less BLV640: 53 VDC or less, 100 mA or less (For the SPEED-OUT output, supply at least 10 mA of current.)

14, 15

7, 8

Pin No.

6

0 V

5

Page 24: Brushless DC Motor and Driver Package BLV Series

7 Connection

−24−

Note • Always connect a current-limiting resistor. If the power supply voltage is connected to the output circuit directly without connecting a current-limiting resistor in between, the driver will be damaged.

• When connecting a relay (inductive load), etc., to detect alarm outputs, use a relay with built-in flywheel diode, or provide a fly-back voltage control measure based on diode, etc., for the inductive load.

14, 15

Pin No.

Inductive load

Flywheeldiode

Input signals The signal state represents the "ON: Carrying current" or "OFF: Not carrying current" state of the internal photocoupler rather than the voltage level of the signal.

• FWD input and REV input When the FWD input is turned ON, the motor turns in the clockwise direction according to the time set by the acceleration time potentiometer. When the FWD input is turned OFF, the motor stops. When the REV input is turned ON, the motor turns in the counterclockwise direction according to the time set by the acceleration time potentiometer. When the REV input is turned OFF, the motor stops. If both the FWD input and REV input are turned ON, the motor stops instantaneously.

• STOP-MODE input Select how the motor should stop when the FWD input or REV input is turned OFF. When the STOP-MODE input is ON, the motor stops according to the time set by the deceleration time potentiometer. STOP-MODE input is OFF, the motor stops instantaneously.

Note When the electromagnetic brake motor is used for vertical drive (gravitational operation), be sure to stop the motor after turning the STOP-MODE input ON. If the motor is stopped while the STOP-MODE input is OFF, the moving part may drop.

• M0 input Select how the motor speed is set. When the M0 input is ON, the motor turns at the speed set by the external potentiometer or external DC voltage. When the M0 input is OFF, the motor turns at the speed set by the internal potentiometer. By switching the M0 input, the motor can be operated at two speeds through use of both the external potentiometer and internal potentiometer. Refer to p.32 for details. You can set a maximum of eight speeds by changing the assignments of M0 to M2 inputs using the OPX-2A.

• ALARM-RESET input This input resets the present alarm that the protective function of the driver was actuated. To reset each alarm, be sure to remove the cause of the alarm before switching the ALARM-RESET input. To reset an alarm, turn both the FWD input and REV input OFF, remove the cause of the alarm, and then turn the ALARM-RESET input ON (and keep it ON for 10 ms or more). The ALARM-RESET input will not be received if the FWD input or REV input is ON. If the alarm cannot be reset with the ALARM-RESET input, cycle the main power. If a control power is used, also cycle the control power.

ALARM-OUT output

ON

OFF

ALARM-RESET inputON

OFF

FWD input

Motor operation

ON

OFF

10 ms or more

10 ms or more

CW CWStop

Electromagnetic brake∗ Release ReleaseLock

∗ The electromagnetic brake locks the moment an alarm generates. You can also use the OPX-2A to cause the electromagnetic brake to lock after a free-run stop of the motor.

Note • Continuing the operation without removing the cause of the alarm may cause damage to equipment.

• Overcurrent and EEPROM errors cannot be reset using the ALARM-RESET input.

Page 25: Brushless DC Motor and Driver Package BLV Series

7 Connection

−25−

• MB-FREE input This input signal is used with electromagnetic brake types. Select how the electromagnetic brake would operate when the motor stops. If the MB-FREE input is ON, the electromagnetic brake will be released. If the MB-FREE input is OFF, the electromagnetic brake will actuate and hold the shaft in position.

Note The MB-FREE input is not accepted while an alarm is present.

Output signals The signal state represents the "ON: Carrying current" or "OFF: Not carrying current" state of the internal photocoupler rather than the voltage level of the signal.

• SPEED-OUT output 30 pulses are output with each revolution of the motor output shaft synchronously with the motor operation. The pulse width of output pulse signals is 0.2 ms. You can use the SPEED-OUT output to calculate the motor speed.

Motor shaft speed (r/min) =

SPEED-OUT output frequency

30× 60

SPEED-OUT output frequency (Hz) =1

T

T

0.2 ms

To display/monitor the speed of the motor output shaft or reduced speed of the gearhead output shaft, connect an accessory digital speed indicator SDM496 (sold separately). See p.47 for details.

• ALARM-OUT output When the driver’s protective function actuates, the ALARM-OUT output turns OFF and the ALARM LED blinks (normally closed). In the case of a standard type, the motor stops naturally. In the case of an electromagnetic brake type, on the other hand, the motor stops instantaneously, upon which the electromagnetic brake actuates and holds the shaft in position. To reset an alarm, turn both the FWD input and REV input OFF, remove the cause of the alarm, and then turn the ALARM-RESET input ON (and keep it ON for 10 ms or more). The ALARM-RESET input will not be received if the FWD input or REV input is ON. If the alarm cannot be reset with the ALARM-RESET input, cycle the main power. If a control power is used, also cycle the control power.

ALARM-OUT output

ON

OFF

ALARM-RESET inputON

OFF

FWD input

Motor operation

ON

OFF

10 ms or more

10 ms or more

CW CWStop

Electromagnetic brake∗ Release ReleaseLock

∗ The electromagnetic brake locks the moment an alarm generates. You can also use the OPX-2A to cause the electromagnetic brake to lock after a free-run stop of the motor.

• WNG output This signal is output when a warning generates. However, the operation will continue. The WNG output will turn OFF automatically once the cause of the warning is removed.

WNG output

ON

OFF

10 ms or less10 ms or less

Warning Generate

Page 26: Brushless DC Motor and Driver Package BLV Series

7 Connection

−26−

Warning list Warning type Cause Remedial action

Main circuit overheat

The temperature inside the driver exceeded the overheat warning level.

Review the ventilation condition in the enclosure.

Undervoltage∗ The main power supply voltage dropped by approx. 10% or more from the rated voltage.

• Check the input voltage of the power supply.

• Check the power supply cable wiring.

Overload∗ The load torque of the motor e exceeded the overload warning level.

• Reduce the load. • Change the operation pattern including

the acceleration/ deceleration time.

Operation error

• When performing test operation using the OPX-2A, any of the input signal for operation was ON.

• When changing the assignment of the input terminal using the OPX-2A, the assigned terminal was ON.

Turn the input signals OFF.

∗ The detection level can be changed using the OPX-2A.

Using a controller with a built-in clamp diode If a controller with a built-in clamp diode is used, a leakage path may form and cause the motor to operate even when the controller power is off, as long as the driver power is on. Since the power capacity of the controller is different from that of the driver, the motor may operate when the controller and driver powers are turned on or off simultaneously. When powering down, turn off the driver power first, followed by the controller power. When powering up, turn on the controller power first, followed by the driver power.

External controlequipment Driver

1 to 4, 9, 10

5

VCC +15 V

0 V

0 V

7.4 Connecting the communication cable Connect the cable of the OPX-2A to the communication connector (CN7). Refer to the USER MANUAL RS-485 Communication Mode for connection of RS-485 communication.

OPX-2A cable

Page 27: Brushless DC Motor and Driver Package BLV Series

7 Connection

−27−

7.5 Connection diagram (Example) Each connection diagram (example) applies to an electromagnetic brake type. With a standard type, the electromagnetic brake need not be connected and the MB-FREE input need not be connected or input.

Sink logic In the connection example given below, the motor is operated with relays, switches and other contact switches.

FWD1

CN4CN2

CN3

CN8

3.3 kΩ

2

+

CN1

-

+

-

3

4

9

10

5

13

12

11

6

CN4

5

14

7

15

8

REV

STOP-MODE

M0

ALARM-RESET

MB-FREE

IN-COM IN-COM

SPEED-OUT

∗2

∗1

∗2

WNG (+)

WNG (-)

ALARM-OUT (+)

ALARM-OUT (-)

+15 V

0 V 0 V

0 V

Motor power connector

Driver

Motor signal connector

Electromagnetic brake connector

BLV620: 24 VDC±10%BLV640: 48 VDC±10%

DC power supply

2

1

3 VH

VM

VL

VM

VL

ExternalpotentiometerPAVR-20KZ (accessory)

ExternalDC voltage(Not to exceed thevoltage selected bySW1-No.2)

BLV620: 30 VDC or less 10 mA or lessBLV640: 53 VDC or less 10 mA or less

BLV620: 30 VDC or less 100 mA or lessBLV640: 53 VDC or less 100 mA or less

∗1 Connect a current-limiting resistor based on the power supply voltage if the current exceeds 10 mA. ∗2 Connect a current-limiting resistor based on the power supply voltage if the current exceeds 100 mA.

Source logic In the connection example given below, the motor is operated with sequence connection of transistor type.

FWD1

CN4CN2

CN3

CN8

3.3 kΩ

2

+

CN1

-

+

-

3

4

9

10

5

13

12

11

6

CN4

5

14

7

15

8

REV

STOP-MODE

M0

ALARM-RESET

MB-FREE

IN-COM

IN-COM

SPEED-OUT

∗2

∗1

∗2

WNG (+)

WNG (-)

ALARM-OUT (+)

ALARM-OUT (-)

0 V

0 V

Driver

15 to 26.4 VDC50 mA or more

DC power supply

2

1

3 VH

VM

VL

VM

VL

0 VExternalpotentiometerPAVR-20KZ (accessory)

ExternalDC voltage(Not to exceed thevoltage selected bySW1-No.2)

Motor power connector

Motor signal connector

Electromagnetic brake connector

BLV620: 24 VDC±10%BLV640: 48 VDC±10%

BLV620: 30 VDC or less 10 mA or lessBLV640: 53 VDC or less 10 mA or less

BLV620: 30 VDC or less 100 mA or lessBLV640: 53 VDC or less 100 mA or less

∗1 Connect a current-limiting resistor based on the power supply voltage if the current exceeds 10 mA. ∗2 Connect a current-limiting resistor based on the power supply voltage if the current exceeds 100 mA.

Page 28: Brushless DC Motor and Driver Package BLV Series

8 Operation

−28−

8 Operation This chapter explains the operations that can be performed with the BLV Series.

8.1 Operation overview With the BLV Series, you can perform three types of operations including basic operations, extended operations using the OPX-2A and operation via RS-485 communication. The table below shows the details of each operation and the reference pages.

Type of operation What you can do Description Ref. Internal potentiometer Set the speed using the internal potentiometer.

External potentiometer Set the speed using the external potentiometer.

Speed setting

External DC voltage Set the speed using an external DC voltage.

P.29

Run/stop Run/stop the motor. P.30 Setting the acceleration time and deceleration time

You can set the acceleration time and deceleration time for starting and stopping. P.31

2-speed operation Operation can be performed at two speeds through use of both the external potentiometer (external DC voltage) and internal potentiometer.

P.32

Examples of operation patterns Examples of run/stop are explained using timing charts. P.33

Multi-motor control A single external potentiometer (external DC voltage) can be used to set the same speed for multiple motors.

P.35

Speed response selection

Select the compliance with respect to commanded speed. P.32

Torque limiting The output torque of the motor can be limited. P.33

Basic operation

Function Sink logic/Source logic selection

Switches the input logic between sink logic and source logic. P.34

Extended operations using OPX-2A

The following functions are extended when the OPX-2A is used. Refer to p.38 for the assignments of I/O signals as well as operation patterns when eight speeds are set: • Operating speed (maximum of 8 speeds) • Acceleration time, Deceleration time (Individual setting) • Torque limiting (Individual setting) • Change of I/O signal assignments • Function of analog setting/digital setting • Various displays (speed, alarm code, load factor) • I/O monitor • Warning output • Test operation • Data copy • Setting the operation input mode

P.38

Control via RS-485 communication

Modbus protocol can be used in RS-485 communication. Refer to the USER MANUAL RS-485 Communication Mode for details. −

Page 29: Brushless DC Motor and Driver Package BLV Series

8 Operation

−29−

8.2 Basic operation

Speed setting The setting range is 100 to 4000 r/min.

• Setting by internal potentiometer Use a precision screwdriver to turn the internal potentiometer. Turn the potentiometer clockwise to increase the speed. Factory setting: 0 r/min Slow

Fast

• Setting by the external potentiometer (accessory) Connect the accessory external potentiometer (sold separately) to the I/O signal connector (CN4) of the driver. When the M0 input is turned ON, the external potentiometer is enabled. Turn the potentiometer clockwise to increase the speed.

CN4

12 VM input

11 VL input

FastSlow

1 2 3

13 VH input

External potentiometer

This figure is the CN4 connectorviewed from the driver front side.

• External potentiometer position vs. speed characteristics (representative values)

500

1000

1500

2000

2500

3000

3500

4000

Moto

r shaft s

peed [r/

min

]0 10080604020

Note When using an external potentiometer, turn the basic function switch (SW1-No.2) OFF.

• Setting with external DC voltage Set either 5 or 10 VDC for the external DC voltage. Select the basic function switch (SW1-No.2) to set which voltage to be used. 5 VDC is set when the switch is set to the OFF position, and 10 VDC is set when the switch is set to the ON position. Factory setting: 5 VDC (OFF)

For the external voltage, use a DC power supply (0 to 5 VDC or 0 to 10 VDC) with reinforced insulation on both the primary side and secondary side, and connect it to the I/O signal connector (CN4).

Basic function switchSW1-No.2ON: 0 to 10 VDCOFF: 0 to 5 VDC

The input impedance between the VM input and VL input is approx. 14 kΩ when the basic function switch (SW1-No.2) is ON, and approx. 47 kΩ when OFF. The VL input is connected to IN-COM1 inside the driver.

0 to 5 VDCor

0 to 10 VDC 1 mA or more

External DC power supply

CN4

12 VM input

11 VL input

This figure is the CN4 connectorviewed from the driver front side.

• External DC voltage vs. speed characteristics (representative values)

0

500

1000

1500

2000

2500

3000

3500

4000

2 4 6 81 3 5 7 109

External DC voltage [V]

Moto

r shaft s

peed [r/

min

]

10 VDC

5 VDC

Note Be sure to set the external DC voltage to either 5 VDC or less, or 10 VDC or less. When connecting the external DC power supply, make sure the polarities are correct. If the polarities are reversed, the driver may be damaged.

Page 30: Brushless DC Motor and Driver Package BLV Series

8 Operation

−30−

Running/stopping the motor Run/stop the motor by inputting operation control signals.

• Operation When the FWD input is turned ON, the motor turns in the clockwise direction according to the time set by the acceleration time potentiometer. When the FWD input is turned OFF, the motor stops. When the REV input is turned ON, the motor turns in the counterclockwise direction according to the time set by the acceleration time potentiometer. When the REV input is turned OFF, the motor stops. If the FWD input and REV input are turned ON at the same time, the motor stops instantaneously.

ON

OFF

ON

OFF

ON

OFFSTOP-MODE input

REV input

FWD input

Motor operation

Deceleration stopInstantaneous stop

Electromagnetic brake Release Release

Note If the motor unit is used in a vertical application, operating the device based on the following settings may cause the shaft to reverse momentarily at start or stop depending on the load conditions (approx. 1/4 rotation at the motor output shaft): · Low motor speed · Long acceleration time or deceleration time

• Stop Select how the motor should stop when the FWD input or REV input is turned OFF. When the STOP-MODE input is ON, the motor stops according to the time set by the deceleration time potentiometer. STOP-MODE input is OFF, the motor stops instantaneously.

FWD input REV input STOP-MODE input Motor status ON OFF − Clockwise rotation OFF ON − Counterclockwise rotation ON ON − Instantaneous stop − − OFF Instantaneous stop − − ON Deceleration stop

Note When the electromagnetic brake motor is used for vertical drive (gravitational operation), be sure to stop the motor after turning the STOP-MODE input ON. If the motor is stopped while the STOP-MODE input remains OFF status, the moving part may drop.

Page 31: Brushless DC Motor and Driver Package BLV Series

8 Operation

−31−

Rotating direction of the motor output shaft The rotating direction of the motor output shaft represents the direction when viewed from the motor output shaft side.

• Combination type parallel shaft gearhead The rotating direction of the motor output shaft may vary from that of the gearhead output shaft depending on the gear ratio of the gearhead.

Gear ratio Rotating direction of gearhead output shaft

5, 10, 15, 20, 100, 200 Same as the motor output shaft 30, 50 Opposite to the motor output shaft

REV input

FWD input

• Combination type hollow shaft flat gearhead For all gear ratios, the output shaft turns in the opposite direction to the motor. The direction is different depending on whether the motor/gearhead assembly is viewed from the front side or rear side.

FWDinput REV

input

FWDinputREV

input

• Viewed from Front • Viewed from Rear

8.3 Setting the acceleration time and deceleration time You can set the acceleration time and deceleration time for starting and stopping. The acceleration time and deceleration time are effective for all speed settings. The acceleration time and deceleration time are same value. It cannot be set individually. Set the acceleration/deceleration time using the acceleration/deceleration time potentiometer (VR2). Turning the potentiometer clockwise increases the time. Acceleration time refers to the time needed for the motor to reach the rated speed (3000 r/min) from the stationary state. Deceleration time refers to the time needed for the motor to stop from the rated speed (3000 r/min).

Setting range: 0.2 to 15 sec Factory setting: 0.2 sec

Slow

Fast

t1 t2

3000 r/min t1, t2 = 0.2 to 15 sec (3000 r/min)

The actual acceleration time and deceleration time vary depending on the conditions of use, load inertia, load torque, etc. If smooth acceleration operation or deceleration operation is not possible, increase the acceleration time or deceleration time.

Page 32: Brushless DC Motor and Driver Package BLV Series

8 Operation

−32−

8.4 Speed response selection Select the motor response in reaction to the command speed using the basic function switch (SW1-No.1). When operating a large inertial load, hunting at starting a motor can be eliminated with the low-response setting.

Setting range: OFF (Low-response) ON (High-response) Factory setting: OFF (Low-response)

Time

Speed

High-response(SW1-No.1: ON)

Low-response(SW1-No.1: OFF)

Basic function switchSW1-No.1ON: High-responseOFF: Low-response

Note • Cycle the main power after switching the basic function switch (SW1-No.1). If a control power is used, also cycle the control power.

• When using the electromagnetic brake motor in vertical drive (gravitational operation), set the basic function switch to high-response (ON).

8.5 2-speed operation Operation can be performed at two speeds through use of both the internal potentiometer and external potentiometer (external DC voltage). When the M0 input is ON, the motor turns at the speed set by the external potentiometer or external DC voltage. When the M0 input is OFF, the motor turns at the speed set by the internal potentiometer.

ON

OFF

ON

OFF

ON

OFF

ON

OFF

FWD input

REV input

STOP-MODE input

Motor operation

External potentiometer

M0 input

Instantaneous stop

Internal potentiometer

Internalpotentiometer

CW

CCW

External potentiometer

Electromagnetic brake operation Release Release

Deceleration stop

Page 33: Brushless DC Motor and Driver Package BLV Series

8 Operation

−33−

8.6 Examples of operation patterns The charts below are examples of setting the internal potentiometer to 3000 r/min and external potentiometer to 1000 r/min and switching the speed between these two levels.

ON

OFF

ON

OFF

ON

OFF

ON

OFF

STOP-MODE input

REV input

FWD input

3000 r/min

1000 r/min

M0 input

Motor operation

CW

Run/Speed change/ Stop

Run/Instantaneous stop

Rotation direction change/Instantaneous reverse

Acceleration operation/Deceleration stop/Instantaneous stop during deceleration

CCW

Electromagnetic brake Release Release Release Release Release Release

Note • Make sure each signal remains ON for at least 10 ms. • When switching the FWD input and REV input, provide an interval of at least 10 ms.

If the FWD input and REV input are turned ON at the same time, the motor stops instantaneously regardless of the status of the STOP-MODE input.

ON

OFF

ON

OFF

ON

OFFSTOP-MODE input

REV input

FWD input

Motor operation

Instantaneousstop

CWoperation

CWoperation

Decelerationstop

8.7 Torque limiting function Set the torque limiting value using the torque limiting potentiometer (VR3). A desired torque limiting value can be set as a percentage (%) of the motor rated torque of 100%. When performing the torque limiting operation continuously such as push-motion operation or winding-control operation, set the torque limiting value at 100% or less.

Setting range: 0 to 200% Factory setting: 200%

0% 200%

Page 34: Brushless DC Motor and Driver Package BLV Series

8 Operation

−34−

8.8 Sink logic/Source logic selection With the basic function switch (SW1-No.3), the input circuit of the driver can be switched between sink logic and source logic. The output circuit of the driver can be switched between sink logic and source logic by changing the wiring connection.

In the sink logic input circuit, a signal will be turned ON when the current flows out of the input terminal. In the source logic input circuit, a signal will be turned ON when the current flows into the input terminal. Factory setting is sink logic (OFF).

Basic function switch SW1-No.3ON: Source logicOFF: Sink logic

Switch sink logic or source logic based on the output circuit of the external control device (programmable controller).

Example of connection with I/O signal circuit

Note If the current exceeds 100 mA, connect an external resistor R.

• Sink logic circuit

15 VDC

0 V

0 V

0 V

1

2

3

4

9

10

5

3.3 kΩ

3.3 kΩ

3.3 kΩ

3.3 kΩ

3.3 kΩ

3.3 kΩ

15R

R14

8

7

Programmable controller Driver

BLV620: 30 VDC or less 100 mA or lessBLV640: 53 VDC or less 100 mA or less

100 mA or less

100 mA or less

Page 35: Brushless DC Motor and Driver Package BLV Series

8 Operation

−35−

• Source logic circuit

5

24 VDC

0 V 0 V

0 V

2

1

3

4

9

103.3 kΩ

3.3 kΩ

3.3 kΩ

3.3 kΩ

3.3 kΩ

3.3 kΩ

15R

R14

8

7

Programmable controller Driver

BLV620: 30 VDC or less 100 mA or lessBLV640: 53 VDC or less 100 mA or less 100 mA or less

100 mA or less

8.9 Multi-motor control If two or more motors are to be operated at the same speed by using a single external potentiometer (external DC voltage), this type of operation is called “multi-motor control.” Multi-motor control is achieved by allowing multiple drivers to share the power line and speed setting line. • Connect the external I/O signals to each driver. • To perform multi-motor control using the external potentiometer, set the basic function switch (SW1-No.2) to OFF. • Set the basic function switch (SW1-No.2) the same way for all the drivers.

Using an external potentiometer Connect the drivers as shown below. When performing multi-motor control using the external potentiometer, the number of drivers should not exceed 20 units.

470 Ω, 1/4 W

VRn1 kΩ, 1/4 W

Speed setting line

External potentiometerVRx

132

Driver 1 Driver n

VM

VL

VH

VM

VL

VH

Power input +- Power line

Resistance (VRx) when the number of drivers is n: Resistance (VRx) = 20/n (kΩ), n/4 (W)

Example: If two drivers are used Resistance (VRx) = 20/2 (kΩ), 2/4 (W), resistance (VRx) is calculated as 10 kΩ, 1/2 W. (Use a resistor of the calculated wattage or more.) If the speed will vary among the respective motors, make adjustments by connecting a resistor of 470 Ω, 1/4 W to terminal VM on driver 1 and connecting a variable resistor VRn of 1 kΩ, 1/4 W to driver 2 and subsequent drivers.

Page 36: Brushless DC Motor and Driver Package BLV Series

8 Operation

−36−

Using external DC voltage Connect the drivers as shown below.

0 to 5 VDCor

0 to 10 VDC

DC power supply

VM

VL

VH

VM

VL

VH

+-

470 Ω, 1/4 W

VRn1 kΩ, 1/4 W

Speed setting line

Driver 1 Driver n

Power input Power line

Current capacity (I) of external DC power supply when the number of drivers is n: Current capacity (I) = 1 × n (mA)

Example: If two drivers are used Current capacity (I) = 1 × 2 (mA), current capacity (I) is calculated as 2 mA or more. If the speed will vary among the respective motors, make adjustments by connecting a resistor of 470 Ω, 1/4 W to terminal VM on driver 1 and connecting a variable resistor VRn of 1 kΩ, 1/4 W to driver 2 and subsequent drivers.

Page 37: Brushless DC Motor and Driver Package BLV Series

9 Extended functions

−37−

9 Extended functions When an accessory data setter OPX-2A (sold separately) is used, the specifications and functions are extended and various operation can be performed. For details, refer to the operating manual for the OPX-2A. This section explains extended functions using the OPX-2A.

9.1 Extended items

Specification Item Standard specification Specification when using OPX-2A

Speed setting range 100 to 4000 r/min Set with the potentiometer VR1

80 to 4000 r/min Set digitally in 1 r/min increments.

Speed control accuracy ±0.5% ±0.2%

Acceleration time The time needed to reach the rated speed (3000 r/min).

Deceleration time The time needed for the motor to stop from the rated speed (3000 r/min).

The time needed to reach the target speed from the current speed

Function Function Description OPX-2A mode

Various displays

• Operating speed • Transfer speed • ON/OFF status of each I/O signal • Load factor • Alarm code • Warning code

Monitor mode

Multi-speed setting Up to 8 operation data can be set. Set the rotation speed, torque limiting value, acceleration time and deceleration time in operation data.

Torque limit The motor torque limiting value can be set in operation data.

Data mode

Various functions

• Speed reduction ratio • Speed increasing ratio • Conveyor speed reduction ratio • Conveyor speed increasing ratio • Rotating speed attainment band • Motor direction selection

Change of I/O signal assignments I/O signal assignments can be changed.

Warning output Warning functions can be set to output a warning signal before the corresponding alarms generate.

Digital/Analog input switching

The functions assigned to the potentiometers of the driver can be changed, and also the setting method of the operation data can be switched between analog setting and digital setting (p.41).

Parameter mode

Test function • I/O test • Test operation (JOG operation)

Test mode

Copy function • Data copy • Initializing the setting

Copy mode

Page 38: Brushless DC Motor and Driver Package BLV Series

10 Operation using a data setter OPX-2A

−38−

10 Operation using a data setter OPX-2A This chapter explains the setting and operation using a data setter OPX-2A. Refer to the OPX-2A OPERATING MANUAL for details of setting contents and operation.

10.1 Setting the operation data Up to eight sets of operation data can be set in the data mode. Set the rotation speed, torque limiting value, acceleration time and deceleration time in operation data.

Setting item Initial value Setting range Setting unit Description

Operating speed 0 0 r/min, or 80 to 4000 r/min 1 Set the operating speed.

Torque limiting value 200 0 to 200% 1

When limiting the operation torque, set the torque limiting value as a percentage (%) of the rated torque. The rated torque is being 100%. The initial setting is motor starting torque.

Acceleration time∗ Deceleration time∗ 0.5 0.2 to 15.0 s 0.1 Set the time needed to reach the target

speed from the current speed. ∗ The actual acceleration time and deceleration time vary depending on the conditions of use, load inertia, load torque and

other settings specified by the customer.

10.2 Multi-speed operation A multi-speed operation using up to eight speeds can be performed by setting desired speeds in operation data No.1 to 8 and then switching the speed using the M0 to M2 inputs.

Assignments of I/O signals To perform the multi-speed operation, assign the M0 to M2 inputs to the driver input terminals. Change the assignments with the parameter mode of the OPX-2A.

Input terminal Signal name Description FWD The motor turns in the FWD direction. REV The motor turns in the REV direction. STOP-MODE

2-wire input mode

Select instantaneous stop or deceleration stop.

START/STOP The motor rotates when turning the signal ON. The motor decelerates and stops when turning the signal OFF.

RUN/BRAKE The motor stops instantaneously when turning the signal OFF.

FWD/REV

3-wire input mode

The motor rotates in the FWD direction when turning the signal ON, while in the REV direction when turning the signal OFF.

MB-FREE The electromagnetic brake is released at motor standstill when turning the signal ON.

EXT-ERROR The motor stops when turning the signal OFF. ALARM-RESET Alarms are reset.

HMI Operation of the OPX-2A is disabled. The OPX-2A can be used as a display.

M0 M1

X0 to X5

M2

Select a operation data number based on a combination of ON/OFF states of M0, M1 and M2 inputs.

Page 39: Brushless DC Motor and Driver Package BLV Series

10 Operation using a data setter OPX-2A

−39−

Select the operation data Desired operation data number can be selected by a combination of ON/OFF statuses of M0, M1 and M2 inputs.

Operation data No. M0 input M1 input M2 input 0 OFF OFF OFF 1 ON OFF OFF 2 OFF ON OFF 3 ON ON OFF 4 OFF OFF ON 5 ON OFF ON 6 OFF ON ON 7 ON ON ON

To turn ON the M0, M1 and M2 inputs, wait for at least 10 ms after the FWD input or REV input has turned ON. If an attempt is made to turn ON the M0 to M2 inputs within 10 ms, the M0 to M2 inputs will not be accepted.

ON

OFF

ON

OFF

FWD input

No.0

No.1

No.2

No.3

No.4

No.5

No.6

No.7

M1 input

ON

OFFM2 input

ON

OFFM0 input

Motor operation

10.3 Setting the operation input mode Signal input mode can be switched between 2-wire input mode and 3-wire input mode. The operation input mode is a method to select the motor rotation direction and operation signal. FWD input and REV input are used in 2-wire input mode. START/STOP input, RUN/BRAKE input and FWD/REV input are used in 3-wire input mode. In each operation input mode, signal functions will be changed as follows.

2-wire input mode 3-wire input mode

FWD input START/STOP input (ON: Operation, OFF: Deceleration stop)

REV input RUN/BRAKE input (ON: Operation, OFF: Instantaneous stop)

STOP-MODE input FWD/REV input (ON: Rotate to clockwise, OFF: Rotate to counter clockwise)

Note When the electromagnetic brake motor is used for vertical drive (gravitational operation), set the operation input mode to 2-wire input mode. If 3-wire input mode is selected, the moving part may drop when stopping the motor.

Page 40: Brushless DC Motor and Driver Package BLV Series

10 Operation using a data setter OPX-2A

−40−

Timing chart in the 2-wire input mode

Motor operation

CCW

CW CW CW

CCW

10 ms or more

FWD inputOFF

ON

OFF

ON

OFF

ON

REV input

STOP-MODE input

CW/CCW operationRotation direction switching/Stop mode selection

10 msor more

10 msor more 10 ms or more

Deceleration stop

Deceleration stop

Instantaneous stop

Instantaneous stop Instantaneous

stop

Timing chart in the 3-wire input mode

CW CWCW

CCW

START/STOP inputOFF

ON

OFF

ON

OFF

ON

RUN/BRAKE input

FWD/REV input

InstantaneousCW/CCW operationStop mode selection

10 msor more

10 msor more

10 ms or more

10 ms or more

Motor operation

Instantaneous stop

Decelerationstop

Instantaneous stop∗

∗ If the rotation direction is changed during operation, the rotation direction will be changed after instantaneous stop.

Page 41: Brushless DC Motor and Driver Package BLV Series

10 Operation using a data setter OPX-2A

−41−

10.4 Analog setting/digital setting Analog setting is a method to set the rotation speed or acceleration/deceleration time using the internal potentiometers of the driver or external potentiometer. Digital setting is a method to set them using a data setter OPX-2A. When selecting the mode No. using the parameter mode of the OPX-2A, functions assigned to the driver potentiometers can be changed, and also the setting method of operation data can be switched between analog setting and digital setting.

See a combination of the mode No. and analog setting/digital setting as shown below. Others except the following combination are not available to set. To use this function conveniently, assign the function which value may change frequently to VR1 and VR2, while assign the function which value may fix to VR3.

Mode No. Operation data No. VR1 VR2 VR3 External

potentiometer Digital setting

0 Operating speed Acceleration/ deceleration

time

Torque limiting value − −

1 − Acceleration/ deceleration

time

Torque limiting value Operating speed − Mode 0

(initial setting)

2 to 7 − − − −

Operating speed Acceleration time Deceleration time

Torque limiting value

Mode 1 0 to 7 − − − −

Operating speed Acceleration time Deceleration time

Torque limiting value

Mode 2 0 to 7 − − − Torque limiting value

Operating speed Acceleration time Deceleration time

0 Acceleration time

Deceleration time Operating speed − Torque limiting value

1 Acceleration time

Deceleration time − Operating speed Torque limiting value

Mode 3

2 to 7 − − − −

Operating speed Acceleration time Deceleration time

Torque limiting value

0 Operating speed Torque limiting value

Acceleration/ deceleration

time − −

1 − Torque limiting value

Acceleration/ deceleration

time Operating speed − Mode 4

2 to 7 − − − −

Operating speed Acceleration time Deceleration time

Torque limiting value

0 Torque limiting value

Acceleration/ deceleration

time Operating speed − −

1 Torque limiting value

Acceleration/ deceleration

time − Operating speed − Mode 5

2 to 7 − − − −

Operating speed Acceleration time Deceleration time

Torque limiting value

Note The factory setting of the torque limiting potentiometer (VR3) is set to the maximum value. When selecting the mode No.3, No.4 or No.5, check the setting value well before operating a motor because the rotation speed and acceleration/deceleration value are set to the maximum value initially.

Page 42: Brushless DC Motor and Driver Package BLV Series

10 Operation using a data setter OPX-2A

−42−

Setting example of each mode No. is shown below.

Mode No. Setting example Mode 0 When setting the operating speed and acceleration/deceleration time with analog setting Mode 1 When setting all operation data with digital setting

Mode 2 When setting the torque limiting value using the external potentiometer and setting others with digital setting

Mode 3 When setting the acceleration/deceleration time individually using the internal potentiometers

Mode 4 When fixing the acceleration/deceleration time, and setting the operating speed and torque limiting value with analog setting

Mode 5 When setting the acceleration/deceleration time and torque limiting value using the internal potentiometers

Page 43: Brushless DC Motor and Driver Package BLV Series

11 Inspection

−43−

11 Inspection It is recommended that periodic inspections be conducted for the items listed below after each operation of the motor. If an abnormal condition is noted, discontinue any use and contact your nearest office.

During inspection • The motor/gearhead mounting screws are not loose. • Check for any unusual noises in the motor's bearings (ball bearings) or other moving parts. • The bearing (ball bearing) and gear meshing parts of the gearhead are not generating noise. • The motor/gearhead output shaft is not misaligned with the load shaft. • Are there any scratches, signs of stress or loose driver connections in the cable? • The openings in the driver are not blocked. • The driver mounting screws and power connection terminal screws are not loose. • Are there any strange smells or appearances within the driver?

Note • Conduct the insulation resistance measurement or withstand voltage test separately on the motor and the driver. Conducting the insulation resistance measurement or withstand voltage test with the motor and driver connected may result in injury or damage to equipment.

• The driver uses semiconductor elements, so be extremely careful when handling them. Static electricity may damage the driver.

Page 44: Brushless DC Motor and Driver Package BLV Series

12 Protective function

−44−

12 Protective function When an alarm generates and the driver's protective function is actuated, the ALARM-OUT output will turn OFF. In the case of a standard type, the motor stops naturally and once the motor has stopped, the motor output shaft becomes free. In the case of an electromagnetic brake type, on the other hand, the motor stops instantaneously, upon which the electromagnetic brake actuates and holds the shaft in position. At the same time, the ALARM LED will start blinking. The cause of the alarm can be checked by counting the number of times the ALARM LED blinks.

Blinking pattern example: Sensor error (number of blinks: 3)

0.3 s0.3 s 1.5 s

1 2 3 1 2 3

To reset an alarm, be sure to remove the cause of the alarm and then perform one of the following operations: • Turn the ALARM-RESET input ON for at least 10 ms. (Refer to p.24 for details.) • Cycle the main power.

If a control power is used, also cycle the control power.

Note • Alarms cannot be reset if the FWD input or REV input is ON. Be sure to stop the motor before resetting any alarm.

• Alarms caused by damage to the motor or driver itself cannot be reset using the method explained above. Please contact your nearest office.

• Make sure the ALARM-RESET input remains ON for at least 10 ms. If the ON period is too short, the alarm may not be reset.

• The undervoltage alarm is released automatically when the driver main power supply voltage exceeds the undervoltage detection level. If the FWD input or REV input remains ON status, the motor will rotate concurrently with releasing the alarm.

• If an external stop alarm generates, the motor stops instantaneously.

Page 45: Brushless DC Motor and Driver Package BLV Series

12 Protective function

−45−

Alarm list No. of

ALARM LED blinks

Alarm type Cause Remedial action Reset using the ALARM-RESET

input

2 Overload A load exceeding the rated torque was applied to the motor for 5 seconds or more.

• Decrease the load. • Review the operation pattern

such as acceleration/deceleration time.

Sensor error

The motor sensor signal line experienced an open circuit during operation, or the motor signal connector came off.

3

Initial sensor error

The motor sensor signal line broke or motor signal connector came off before the main power supply was turned on.

Check the connection between the driver and motor.

4 Overvoltage

• The main power supply voltage exceeded the overvoltage detection level. [Detection level] BLV620: approx. 40 VDC BLV640: approx. 72 VDC

• Sudden starting/stopping of a large inertia load was performed.

• Check the main power supply voltage.

• If this alarm occurs during operation, reduce the load or increase the acceleration time or deceleration time.

• When generating the alarm in acceleration, set the speed response to low-response. (p.32)

• When generating the alarm at stopping the motor, set the STOP-MODE to instantaneous stop.

5 Undervoltage

The main power supply voltage dropped the undervoltage detection level. [Detection level] BLV620: approx. 10 VDC BLV640: approx. 20 VDC

• Check the main power supply voltage.

• Check the wiring of the power supply cable.

6 Overspeed The rotating speed of the motor output shaft exceeded approx. 4800 r/min.

• Decrease the load. • Review the operation pattern

such as acceleration/deceleration time.

Possible

7 Overcurrent Excessive current has flown through the driver due to ground fault, etc.

Check the wiring between the driver and motor for damage, and cycle the power.

8 EEPROM error • Stored data was damaged. • Data became no longer

writable or readable.

Initialize the parameters using the OPX-2A, and cycle the power.

9 Main circuit overheat

The temperature inside the driver exceeded the main circuit overheat level.

Review the ventilation condition in the enclosure.

Not possible

10 External stop∗1 The EXT-ERROR input turned OFF. Check the EXT-ERROR input.

11 Initial operation error∗2

The main power supply was cycled when the FWD input or REV input was ON.

Turn the FWD input and REV input OFF, and then cycle the main power supply.

Possible

12 Communication switch setting error

The communication function switch (SW2-No.4) was turned ON.

Turning the communication function switch (SW2-No.4) OFF and then cycle the power. When using RS-485 communication function, refer to the USER MANUAL RS-485 Communication Mode.

Not possible

14 Main circuit output error∗3

The motor drive wire broke or motor power connector came off.

Check the connection between the driver and motor. Possible

∗1 Only when EXT-ERROR is assigned using the OPX-2A. ∗2 This alarm generates when the “Initial operation error” function has been enabled using the OPX-2A. ∗3 This alarm does not generate when the torque limiting value is set to less than 200% .

Note Cycle the power to reset the overcurrent and EEPROM error alarms. If the unit does not operate properly after the power is cycled, internal circuit damage is suspected. Please contact your nearest office.

Page 46: Brushless DC Motor and Driver Package BLV Series

13 Troubleshooting and remedial actions

−46−

13 Troubleshooting and remedial actions During motor operation, the motor or driver may fail to function properly due to an improper speed setting or wiring. When the motor cannot be operated correctly, refer to the contents provided in this section and take appropriate action. If the problem persists, contact your nearest office.

Phenomenon Possible cause Remedial action Connection error in the power supply.

Check the connections between the driver and power supply.

Both the FWD input and REV input are OFF. Turn either FWD input or REV input ON.

Both the FWD input and REV input are ON. Turn either FWD input or REV input ON.

The internal potentiometer is not adjusted.

The factory setting is 0 r/min. Turn the internal potentiometer clockwise.

The potentiometer is not selected correctly.

Turn the M0 input OFF when using the internal potentiometer. Turn the M0 input ON when using the external potentiometer.

The external potentiometer or external DC voltage is not connected correctly.

Check the connection of the external potentiometer or external DC voltage.

The motor does not operate.

The ALARM LED (red) is blinking. An alarm generated due to a protective function being triggered. Refer to p.44 to reset the alarm.

The FWD input and REV input are connected wrongly or otherwise not connected correctly.

Check the connection of the FWD input and REV input. The motor turns in the clockwise direction when the FWD input is ON, and in the counterclockwise direction when the REV input is ON.

The combination type parallel shaft gearhead is using a gear with a gear ratio of 30 or 50.

When the gear ratio of the combination type parallel shaft gearhead is 30 or 50, the rotating direction of the gear output shaft is opposite of the motor output shaft. Accordingly, reverse the FWD input and REV input operations. The motor rotates in the direction

opposite to the specified direction.

A combination type hollow shaft flat gearhead is used.

• With a combination type hollow shaft flat gearhead, the rotating direction of the gear output shaft is opposite of the motor output shaft. Accordingly, reverse the FWD input and REV input operations.

• Is the gearhead viewed in the correct direction? With a combination type hollow shaft flat gearhead, the rotating direction of the gearhead changes according to the direction in which the gearhead is viewed.

The motor (gearhead) output shaft is not misaligned with the load shaft.

Check the coupling condition of the motor (gearhead) output shaft and load shaft.

• Motor operation is unstable. • Motor vibration is too great.

Effect of electrical noise.

Check the operation only with the motor, driver and other external equipment required for operation. If an effect of noise has been confirmed, implement the following countermeasures: · Move the unit farther away from noise generation sources. · Review the wiring. · Change the signal cables to a shielded type. · Install ferrite cores.

The STOP-MODE input is ON. To cause the motor to stop instantaneously, turn the STOP-MODE input OFF. The motor doesn’t stop

instantaneously. The inertial load is large. Reduce the load inertia.

The electromagnetic brake does not hold the load in position. The MB-FREE input is turned ON. Turn the MB-FREE input OFF.

Page 47: Brushless DC Motor and Driver Package BLV Series

14 Accessories (Sold separately)

−47−

14 Accessories (Sold separately)

Digital speed indicator This device displays the speed of the motor output shaft and reduced speed of the gearhead output shaft.

Model: SDM496

Note • The SDM496 is not certified under safety standards. If the SDM496 is combined with a BLV Series unit, the BLV Series unit does not conform to safety standards, either.

• The SDM496 cannot be used with the source logic.

• Basic connection (30 pulse/rotation)

7

5

6

5

6

SDM496 Driver

2

10

9

FG

SPEED signal input SPEED OUT

IN-COMGND

12 pulses/30 pulses select

Power supply inputSingle-phase100-240 V50/60 Hz

Data setter This data setter can be used to set or monitor operation data and parameters.

Model: OPX-2A

DIN rail mounting plate When mounting the driver to a DIN rail, use a DIN rail mounting plate. Use a DIN rail 35 mm (1.38 in.) wide.

Model: PADP03

External potentiometer The motor speed can be set externally.

Model: PAVR-20KZ

Page 48: Brushless DC Motor and Driver Package BLV Series

• Unauthorized reproduction or copying of all or part of this manual is prohibited. If a new copy is required to replace an original manual that has been damaged or lost, please contact your nearest Oriental Motor branch or sales office.

• Oriental Motor shall not be liable whatsoever for any problems relating to industrial property rights arising from use of any information, circuit, equipment or device provided or referenced in this manual.

• Characteristics, specifications and dimensions are subject to change without notice. • While we make every effort to offer accurate information in the manual, we welcome your input. Should you find unclear

descriptions, errors or omissions, please contact the nearest office. • is a registered trademark or trademark of Oriental Motor Co., Ltd., in Japan and other countries.

Other product names and company names mentioned in this manual may be registered trademarks or trademarks of their respective companies and are hereby acknowledged. The third-party products mentioned in this manual are recommended products, and references to their names shall not be construed as any form of performance guarantee. Oriental Motor is not liable whatsoever for the performance of these third-party products.

© Copyright ORIENTAL MOTOR CO., LTD. 2011

Printed on Recycled Paper

• Please contact your nearest Oriental Motor office for further information.

Technical Support Tel:(800)468-39828:30 A.M. to 5:00 P.M., P.S.T. (M-F)7:30 A.M. to 5:00 P.M., C.S.T. (M-F)E-mail: [email protected]

Headquarters and Düsseldorf OfficeTel:0211-52067-00 Fax:0211-52067-099Munich Office Tel:089-3181225-00 Fax:089-3181225-25Hamburg OfficeTel:040-76910443 Fax:040-76910445

Tel:01256-347090 Fax:01256-347099

Tel:01 47 86 97 50 Fax:01 47 82 45 16

Tel:02-93906346 Fax:02-93906348

Tel:(02)8228-0707 Fax:(02)8228-0708

Tel:+65-6745-7344 Fax:+65-6745-9405

Tel:(03)22875778 Fax:(03)22875528

KOREATel:080-777-2042 Fax:02-2026-5495

Headquarters Tokyo, JapanTel:03-6744-0361 Fax:03-5826-2576

Tel:+66-2-251-1871 Fax:+66-2-251-1872

Tel:400-820-6516 Fax:021-6278-0269