BRITISH STANDARD CABLES - QPARTNERS...BS 6724 BS 6724 CONTROL BRITISH STANDARD CABLES 3 2 1 Max....

10

Transcript of BRITISH STANDARD CABLES - QPARTNERS...BS 6724 BS 6724 CONTROL BRITISH STANDARD CABLES 3 2 1 Max....

Page 1: BRITISH STANDARD CABLES - QPARTNERS...BS 6724 BS 6724 CONTROL BRITISH STANDARD CABLES 3 2 1 Max. Operation Temperature CONSTRUCTION 1 2 3 Copper conductor (class 5) PVC insulation
Page 2: BRITISH STANDARD CABLES - QPARTNERS...BS 6724 BS 6724 CONTROL BRITISH STANDARD CABLES 3 2 1 Max. Operation Temperature CONSTRUCTION 1 2 3 Copper conductor (class 5) PVC insulation

BRITISH STANDARD CABLES

TWIN AND EARTHARCTIC GRADE

6181Y6381Y

309_Y HRCU/XLPE/PVC/AWA/PVC

BS 5467BS 5467 CONTROL

BS 6724BS 6724 CONTROL

Page 3: BRITISH STANDARD CABLES - QPARTNERS...BS 6724 BS 6724 CONTROL BRITISH STANDARD CABLES 3 2 1 Max. Operation Temperature CONSTRUCTION 1 2 3 Copper conductor (class 5) PVC insulation

BRITISH STANDARD CABLES

123

Max. OperationTemperature

CONSTRUCTION

123

Copper conductor (class 5)PVC insulation (cold resistant)PVC outer sheath (cold resistant)

SPECIFICATIONSCode : ARCTIC GRADEStandards : BS 7919Rated voltage : Uo/U=300/500 V

Application :Used in low mechanical stress applications in dry or humidplaces, especially at home appliances such as connectioncables. Insulation and outer sheath compound are resistant tolow temperature which makes cable usable at sub-zerotemperature conditions.

Temperature Range

C60

Short CircuitTemperature

150C

Flame RetardantIEC 60332 -1-2

Min. Bending Radius RoHS

-40 / +50 Co

Flexible

rD<12=5DD>12=6D

Cold Resistance

ARCTIC GRADE

86

12

3

123

Copper conductor (class 1-2)PVC insulationPVC outer sheath

SPECIFITATIONSCode : TWIN AND EARTH / 624_YStandards : BS 6004Rated voltage : Uo/U=300/500 V

Application :Used in low mechanical stress applications in dry or humidplaces, especially at home appliances such as connectioncables. Not useful for outdoor applications.

Temperature Range

-20 / +60 Co

Max. Operation Temperature

C

60

Short Circuit Temperature

150C

Flame RetardantIEC 60332 -1-2

Min. Bending Radius RoHS

rr=6 x D

TWIN AND EARTH

Temperature Range

C60

Short CircuitTemperature

150C

Flame RetardantIEC 60332 -1-2

Min. Bending Radius RoHS

-40 / +50 Co

Flexible

rD<12=5DD>12=6D

Cold ResistanceTemperature Range

C60

Short CircuitTemperature

150C

Flame RetardantIEC 60332 -1-2

Min. Bending Radius RoHS

-40 / +50 Co

Flexible

rD<12=5DD>12=6D

Cold Resistance

CONSTRUCTION

Page 4: BRITISH STANDARD CABLES - QPARTNERS...BS 6724 BS 6724 CONTROL BRITISH STANDARD CABLES 3 2 1 Max. Operation Temperature CONSTRUCTION 1 2 3 Copper conductor (class 5) PVC insulation

BRITISH STANDARD CABLES

87

CONSTRUCTION

123

Copper conductor (class 5)PVC insulationPVC outer sheath

SPECIFICATIONSCode : 6381YStandards : BS 6004Rated voltage : Uo/U=300/500 V

Application :Used in low mechanical stress application in dry or humid placessuch as manufacturing facilities and office etc. over and underplaster.

Temperature Range

-20 / +60 Co

Max. OperationTemperature

C

70Short CircuitTemperature

160C

Flame RetardantIEC 60332 -1-2

Min. Bending Radius RoHS

rr=6 x D

6381Y

123

CONSTRUCTION

123

Copper conductor (class 1-2)PVC insulationPVC outer sheath

SPECIFICATIONSCode : 6181YStandards : BS 6004Rated voltage : Uo/U=300/500 V

Application :Used in low mechanical stress application in dry or humid placessuch as manufacturing facilities and office etc. over and underplaster.

Temperature Range

-20 / +60 Co

Max. OperationTemperature

C

70Short CircuitTemperature

160C

Flame RetardantIEC 60332 -1-2

Min. Bending Radius RoHS

rr=6 x D

6181Y

123

Flexible

Page 5: BRITISH STANDARD CABLES - QPARTNERS...BS 6724 BS 6724 CONTROL BRITISH STANDARD CABLES 3 2 1 Max. Operation Temperature CONSTRUCTION 1 2 3 Copper conductor (class 5) PVC insulation

BRITISH STANDARD CABLES

88

CONSTRUCTION

12345

Copper conductor (class 2)XLPE insulationPVC separation sheathAluminium wirePVC outer sheath

SPECIFICATIONSCode : Cu/XLPE/PVC/AWA/PVCStandards : BS 5467Rated voltage : Uo/U= 0.6/1 kV

Application :Mainly used in populated areas, power and switching stationsand underground. Through its armoured structure, cables iscompletely protected from mechanical damage.

Temperature Range Max. OperatingTemperature

C

90Short CircuitTemperature

250C

Flame RetardantIEC 60332 -1-2

Min. Bending Radius

rr=15 x D

RoHS

-20 / +60 C

Mechanical Resistance

CU/XLPE/PVC/AWA/PVC

BASEC Certificate

12345

CONSTRUCTION

123

Copper conductor (class 5)PVC insulation (heat resistant)PVC outer sheath (heat resistant)

SPECIFICATIONSCode : 309_Y HRStandards : BS 6500Rated voltage : Uo/U=300/500 V

Application :Used in low mechanical stress applications in dry or humidplaces, especially at home appliances such as connectioncables. Outer sheath compound is resistant to high temperaturewhich makes cable usable at very hot conditions.

309_Y HR

Temperature Range

-20 / +80 Co

Max. OperationTemperature

C90

Short CircuitTemperature

150C

Flame RetardantIEC 60332 -1-2

Min. Bending Radius RoHSFlexible

rD<12=5DD>12=6D

123

Page 6: BRITISH STANDARD CABLES - QPARTNERS...BS 6724 BS 6724 CONTROL BRITISH STANDARD CABLES 3 2 1 Max. Operation Temperature CONSTRUCTION 1 2 3 Copper conductor (class 5) PVC insulation

CONSTRUCTION

123456

Copper conductor (class 2)XLPE insulationPolyester tapePVC BeddingGalvanized round steel wirePVC outer sheath

SPECIFICATIONS

Code : CU/XLPE/SWA/PVCStandards : BS 5467Rated Voltage : Uo/U= 0.6/1 kV

Application :Mainly used in populated areas, power and switching stationsand underground. Through its steel wire armoured structure,cable is completely protected from mechanical damage risk.

BS5467

Temperature Range Max. OperatingTemperature

Short CircuitTemperature

Flame RetardantIEC 60332 -1-2

Min. Bending Radius RoHS

C

90-20 / +60 C

r250C

Mechanical Resistance

r=15 x D

PHYSICAL AND ELECTRICAL PROPERTIES

BRITISH STANDARD CABLES

BASEC Certificate

mm2 mm kg/km m ½ / km (max.) A Acm12141516192126281315161820232830323841465055616314161720232730

300390470580860

113017002100

335440550770

1000135020402560290041005250678081009800

1225014900

400510640890

120017802430

1000100010001000100010001000100010001000100010001000100010001000100010001000

500500500500500

1000100010001000100010001000

3140526486

112145174

3140526486

112145174206254305348392444517585

3140526486

112145

243242537498

133162

243242537498

133162197250308359412475564649

243242537498

133

12.17.414.613.081.831.15

0.7270.524

12.17.414.613.081.831.15

0.7270.5240.3870.2680.1930.1530.124

0.09910.07540.0601

12.17.414.613.081.831.15

0.727

3x1.53x2.53x43x63x103x163x253x354x1.54x2.54x44x64x104x164x254x354x504x704x954x1204x1504x1854x2404x3005x1.55x2.55x45x65x105x165x25

rmrmrmrmrmrmrmrmrmrmrmrmrmrmrmrmsmsmsmsmsmsmsmsmrmrmrmrmrmrmrm

809090

100110120140150

8090

100110120130150150160200200180200210220220

90100100120130140150

Earth Air

Current carrying capacity in (30°C)Nominalcross-section

Overalldiameterapprox.

Net weightapprox.

Standartdelivery length

Conductor DCresistance

at 20°C

Delivery drumtype

12346 5

89

Page 7: BRITISH STANDARD CABLES - QPARTNERS...BS 6724 BS 6724 CONTROL BRITISH STANDARD CABLES 3 2 1 Max. Operation Temperature CONSTRUCTION 1 2 3 Copper conductor (class 5) PVC insulation

CONSTRUCTION

12345

Copper conductor (class 2)XLPE insulationPVC BeddingGalvanized round steel wirePVC outer sheath

SPECIFICATIONS

Code : Cu/XLPE/SWA/PVCStandards : BS 5467Rated Voltage : Uo/U=0.6/1 kV

Application :Used as control cables in energy panels of power centres andindustrial buildings etc. internally, externally or underground inwhere hard working conditions are necessary.

BS 5467

mm2 mm kg/km ½ / km (max.) A Am

12345

Temperature Range Max. OperatingTemperature

Short CircuitTemperature

Flame RetardantIEC 60332 -1-2

Min. Bending Radius RoHS

C

90-20 / +60 C

r250C

Mechanical Resistance

r=15 x D

PHYSICAL AND ELECTRICAL PROPERTIES

BRITISH STANDARD CABLES

BASEC Certificate

Earth Air

Current carrying capacity in (30°C)Nominalcross-section

Overall diameterapprox.

Net weightapprox.

Conductor DCresistance

at 20°C

Delivery drum typefor 1000 m. cable

151819202224262830172022242627293135

450615775820975

1200138015501875590810

1020123014601600185020802750

90110110120120130140150150100120120130140140150160180

12.112.112.112.112.112.112.112.112.17.417.417.417.417.417.417.417.417.41

242424242424242424323232323232323232

313131313131313131404040404040404040

7x1.510x1.512x1.514x1.519x1.521x1.524x1.530x1.540x1.57x2.5

10x2.512x2.514x2.519x2.521x2.524x2.530x2.540x2.5

rmrmrmrmrmrmrmrmrmrmrmrmrmrmrmrmrmrm

90

Page 8: BRITISH STANDARD CABLES - QPARTNERS...BS 6724 BS 6724 CONTROL BRITISH STANDARD CABLES 3 2 1 Max. Operation Temperature CONSTRUCTION 1 2 3 Copper conductor (class 5) PVC insulation

CONSTRUCTION

12345

Copper conductor (class 2)XLPE insulationLSZH beddingGalvanized round steel wireLSZH outer sheath

SPECIFICATIONS

PHYSICAL AND ELECTRICAL PROPERTIES

TemperatureRange

Max. OperatingTemperature

Short CircuitTemperature

Flame RetardantIEC 60332 -1-2

Min. BendingRadius

RoHS

-20 / +70 C

C

90 r250C

Flame RetardantIEC 60332 -3-24 Cat.C

CIBr FI

Halogen FreeIEC 60754-1/2

Low Smoke EmissionIEC 61034-1/2

r=15 x D

1235 4

mm2 mm kg/km m ½ / km (max.) A A

Earth Air

Current carrying capacity in (30°C)Nominalcross-section

Overall diameterapprox.

Net weightapprox. Delivery length

Conductor DCresistance

at 20°C

cm

Delivery drumtype

121415161921262830131516182023283032374146505561651415171922263033

3x1.53x2.53x43x63x103x163x253x353x504x1.54x2.54x44x64x104x164x254x354x504x704x954x1204x1504x1854x2404x3005x1.55x2.55x45x65x105x165x255x35

rmrmrmrmrmrmrmrmsmrmrmrmrmrmrmrmrmsmsmsmsmsmsmsmsmrmrmrmrmrmrmrmrm

3140526486

1121451742063140526486

1121451742062543053483924445175853140526486

112145174

243242537498

133162197243242537498

133162197250308359412475564649243242537498

133162

809090

1001101201401501508090

1001101201301501501601802001802002102202409090

100110120140150160

300380470570860

1120170021002400330440535760

100013302025255031004340558072008750

105501307015900

390494625875

1200175024003050

10001000100010001000100010001000100010001000100010001000100010001000100010001000500500500500500

10001000100010001000100010001000

12,17,414,613,081,831,15

0,7270,5240,38712,17,414,613,081,831,15

0,7270,5240,3870,2680,1930,1530,124

0,09910,07540,0601

12,17,414,613,081,831,15

0,7270,524

Code : Cu/XLPE/LSZH/SWA/LSZHStandards : BS 6724Rated Voltage : Uo/U=0.6/1 kV

Application :These cables can withstand mechanical stress. Used in placeswhich are subject to fire danger such as hotels, hospitals, shoppingcenters, power plants, information technology centers and inplaces where human groups are carried by railway systems andalso where valuable equipments are kept. These cables do notconduct flame during fire, do not create high smoke density, donot create corrosive ambients and therefore provides increasedprotection. Can be used internally, externally or in underground.

BRITISH STANDARD CABLES

91

BS 6724

Page 9: BRITISH STANDARD CABLES - QPARTNERS...BS 6724 BS 6724 CONTROL BRITISH STANDARD CABLES 3 2 1 Max. Operation Temperature CONSTRUCTION 1 2 3 Copper conductor (class 5) PVC insulation

CONSTRUCTION

12345

Copper conductor (class 2)XLPE insulationLSZH BeddingGalvanized round steel wireLSZH outer sheath

SPECIFICATIONS

Code : Cu/XLPE/LSZH/SWA/LSZHStandards : BS 6724Rated Voltage : Uo/U=0.6/1 kV

Application :Used as control cables in energy panels of power centres athuman densed places or buildings internally, externally orunderground. Due to its characteristics; these cables do notconduct flame. Neither high smoke density nor corrosive ambients are are released from these cables during fire.

BS 6724

mm2 mm kg/km ½ / km (max.) A Am

12345

TemperatureRange

Max. OperatingTemperature

Short CircuitTemperature

Flame RetardantIEC 60332 -1-2

Min. BendingRadius

RoHS

C

90-20 / +60 C

r250C

MechanicalResistance

r=15 x D

PHYSICAL AND ELECTRICAL PROPERTIES

BASEC Certificate

Earth Air

Current carrying capacity in (30°C)Nominalcross-section

Overall diameterapprox.

Net weightapprox.

Conductor DCresistance

at 20°C

Delivery drum typefor 1000 m. cable

151819202224262830172022242627293135

450615775820975

1200138015501875590810

1020123014601600185020802750

90110110120120130140150150100120120130140140150160180

12.112.112.112.112.112.112.112.112.17.417.417.417.417.417.417.417.417.41

242424242424242424323232323232323232

313131313131313131404040404040404040

7x1.510x1.512x1.514x1.519x1.521x1.524x1.530x1.540x1.57x2.5

10x2.512x2.514x2.519x2.521x2.524x2.530x2.540x2.5

rmrmrmrmrmrmrmrmrmrmrmrmrmrmrmrmrmrm

92

Flame RetardantIEC 60332 -3-24 Cat.C

BRITISH STANDARD CABLES

Page 10: BRITISH STANDARD CABLES - QPARTNERS...BS 6724 BS 6724 CONTROL BRITISH STANDARD CABLES 3 2 1 Max. Operation Temperature CONSTRUCTION 1 2 3 Copper conductor (class 5) PVC insulation