part of Aker BP King Subsea Pump Project BP King Subsea Pump Project Record breaking subsea boosting project f C/ Katrine Kierulf, UTC/Bergen, 5 June 2008 © 2008 Aker Solutions

Transcript of BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC...

Page 1: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

part of Aker

BP King Subsea Pump ProjectBP King Subsea Pump ProjectRecord breaking subsea boosting project

f C/Katrine Kierulf, UTC/Bergen, 5 June 2008

© 2008 Aker Solutions

Page 2: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Aker Solutions – Who we are & what we do

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 2

Page 3: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Agenda

■ Project Overview – Aker Solutions Scope of Work■ Technological challengesg g■ High pressure housing design ■ Lube oil control system■ High voltage power supply system■ Control and monitoring system ■ Deep water installation and retrieval methods■ Operational experience

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 3

Page 4: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Substantial IOR!“The two pumps will enhance production

from the King field by an average of 20 per cent. After its 2002 start-up, the

King field reached peak production inKing field reached peak production in 2004, with recent production averaging 27,000 barrels of oil equivalent a day. In addition to the increase in production, pthis project will allow a seven per cent increase in recovery factor, extending the economic life of the field by five

years ”years.

Technological success! – bringing a prototype to a 1700 m commercial application1700 m commercial application

“At 5,500 feet below the sea’s surface, the King facilities are in water almost twice as deep as the previous deepest installation of multi-phase pumps.twice as deep as the previous deepest installation of multi phase pumps. The pumps are also positioned over 15 miles from the Marlin tension leg

platform – well over twice the previous record distance from a host platform of six miles.”

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 4

- BP press release 4 December 2007

Page 5: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

King Subsea Pump Project

• Optimize Oil Recovery from the King Field Reservoirs Lube Oil HPUTopside Control

• New deep water enabling technology (deepest booster ever)

• Tied into the existing King subsea i f t t (l t )

System

Topside VSDinfrastructure (longest ever)

AS Pump StationAS Pump Station

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 5

Page 6: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Project Overview – Aker Solutions Scope of Work

■ Management & Engineering■ Performance and Stack-up testingp g■ Pump Modules, 2 off +1 spare■ Pump Manifolds, 2 off 2 off subsea

Pump Stations■ Subsea Control System, SCM 2 off +1 spare ■ Topside Control System, MCS 1 off

Pump Stations

■ Topside Lube Oil HPU, 1 off■ VSD’s, 2 off

HV C t & J■ HV Connectors & Jumpers■ SIT (limited to SCM vs umbilical)

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 6

Page 7: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Basic Design Data

■ Water depth 4900 ft to 5200 ft (1500 to 1700 m)■ Water Depth at Host 3000 ft (1000 m)■ Tie back Distance 18 miles (27 km)■ Tie back Distance 18 miles (27 km)■ Design Pressure 5000 psi■ Max Power 1MW■ Max Delta Pressure 50bars■ Max Delta Pressure 50bars■ Speed 800-1800rpm■ Ff 6.6kV / 120A

Length x Width x Height (ft): Approx Weights

PUMP MODULE 17 x 10 x 14 50 TePUMP MODULE 17 x 10 x 14 50 Te

PUMP MANIFOLD 27 x 12 x 20 40 Te

SCM (Control Module) 5 x 3,5 x 4 1 Te

COMPLETE PUMP STATION

27 x 12 x 23 91 Te

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 7

Page 8: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Pump in Pit for testing

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 8

Page 9: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Pump Unit

Extensive Design Work and TestingPressure vessel design Seal design and testing g gMaterial selection Limited penetrations in pressure shellInternals are included as cartridges

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 9

Page 10: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Testing of Pump Unit Housings

Design Pressure pD = 345 bar (5000 PSI) Casing Test Pressure pT = 493 bar (1.43 x pD)Ambient temperature 20oCpTest Fluid Temperature 80oC

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 10

Page 11: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Lube Oil Control System

Lube Oil System FunctionsLubricates bearings, timing gears and dynamic sealsdynamic sealsProvides cooling oil for motor (~400hp heat input)Pressure compensated dielectric oil for motorp

Dedicated umbilical supply li f hline for each pump

One shared spare line (stand-by)

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 11

( y)

Page 12: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Topside Lube Oil HPU

• 260 gal Inlet Tank260 gal Inlet Tank• 2x160 gal Supply Tanks• N2 Blanketed Tanks• Offline Oil Purifier• Dual HP Pumps• Div 2 Area Rated• Operated by PLC in VSD Container

• All 316SS Skid Frame

L 8,3’ (2770 mm) x H 7,3’ (2440 mm) x W 6,0’ (1980 mm)

The Lube Oil System must be 100% operational for the life of the subsea pump.Lube Oil must be dry to less than 50 ppm water in oil content. Lube Oil must be clean to NAS class 6 maximum.

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 12

Page 13: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Power systemoverviewoverview

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 13

Page 14: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

VSD Container

Siemens Perfect Harmony Drives AKS Control System

• 1 Drive per Pump• 9 kV, 140 amp, 0-70Hz• Air cooled with fans on the roof • Low Harmonics

•Surface Control Unit•Electrical Power Unit

• Low Harmonics• Modular Construction• Redundant Auto-Bypass

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 14

Page 15: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

VSD Building onboard Marlin platform

Skiddi PlSkidding Plan

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 15

Page 16: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Control and monitoring system

■ Subsea part fairly standard compared to wellhead systems (few hydraulic functions, few sensors)

■ Complexity is in ● Topside part (complex logic)

U bili l ( i f HV LV i i )● Umbilical (noise from HV to LV wiring)● Operation with ground fault

10 Mbit/ fib ti i ti d 28 k ( till h t■ 10 Mbit/s fibreoptic communication used over 28 km (still somewhat novel for subsea use)

■ All sensors duplicated (A / B network)■ All sensors duplicated (A / B network)

■ All sensors connected via digital links

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 16

Page 17: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Subsea Control Module

Power / Comms. Connections

Sensor Connections

Hydraulic connections

5 Hydraulic functions2 manifold valves XV1, XV22 d l l XV3 XV42 pump module valves XV3, XV41 common hydraulic function for 6 PVR switching valves

2 Sensor connectors for A / B sensors1 S t f ”f t ” i

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 17

1 Sensor connector for ”future” expansion

Page 18: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

EPU Input section

Output A section

■ Provides power to subsea control system

■ Dual redundant Output A section

Output B section

■ Dual redundant■ Oversized (each channel

can drive appr 4 SCM’s, we h 2)

phave 2)

iSCU■ Fibre Optic modems (for

comms with subsea SCMs)■ File server for data storage■ Allen Bradley PLC for logic

(the ”Brain” of the system)( e a o e sys e )■ IO cards for topside signals■ Local Operator Station with

keyboard

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 18

keyboard

Page 19: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Operator HMI

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 19

Page 20: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

OPDM

■ The OPDM system analyses logged data, and estimates ”time to service” to enable prediction of required intervention

■ Sensor data and calculated signals are captured offshore in the topside part of the control system and transferred for onshore processing and storage.● Suction pressure● Discharge Pressure● Lube Oil Supply pressure (topside)

Offshore data capture/calculation

pp y p ( p )● Lube Oil Supply pressure (subsea)● Lube Oil system temperature (hot end)● Lube Oil system temperature (cold end)● Lube Oil system temperature (cold end)● VSD Output Power● VSD Output Frequency

■ The database is then used for general visualization and analysis

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 20

Page 21: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Deep water installation and retrieval methods

■ Same pump station at both locations, fully assembled unit, 90 tons■ Hook-up by ROV connected flying leads:p y y g

● HV and LV Power● Instruments● Hydraulic Supply● Hydraulic Supply● Lube Oil● Methanol

■ Retrievable Modules:● Pump Module● PVR● PVR● Subsea Control Module

■ Hook-up to Xmas Tree■ Hook up to Xmas Tree● DES MARS™ Choke Insert System

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 21

Page 22: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Installation

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 22

Page 23: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Operational experience

■ Operational since late November 2007, the two pumps will enhance production for the King field by an average of 20 percent and allow a 7 percent increase in recovery extending the economic life of the7 percent increase in recovery, extending the economic life of the field by five years

■ The pump is designed for 3-5 years operation before intervention is required and can then be replaced with a spare pump

BOTH PUMPS ARE RUNNING STABLE■ BOTH PUMPS ARE RUNNING STABLE■ The OPDM system is up and running, and weekly analyses of

logged data is carried out to monitor performancegg p

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 23

Page 24: BP King Subsea Pump ProjectBP King Subsea Pump Projectpossibility.no/utc2008/ps/g4_UTC paper_4.pdf · 2015. 6. 24. · VSD Container Siemens Perfect Harmony Drives AKS Control System

Thank you for your attention!&

Thanks to everyone who contributed to this success!

Q ti ?Questions?

© 2008 Aker Solutions part of AkerUTC 05.06.2008 Slide 24