Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.

15
Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions

Transcript of Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.

Page 1: Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.

Booster Pump/ Compressor Procedures

Rescue 31 Operator Instructions

Page 2: Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.

Open fill station door

Page 3: Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.

Put cylinder into receiving slot

Page 4: Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.

Attach fill valve to bottle

Page 5: Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.

Close bleeder valve

Page 6: Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.

Open fill valve

Page 7: Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.

Open bottle

Page 8: Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.

Close fill station door completely, allowing locking slide to fully

drop

Page 9: Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.

Open supply valve

Page 10: Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.

Increase regulator pressure to desired level

warning! during shut down procedures, regulator pressure should be brought down to 0 psi to reduce pressure on internal spring and diaphram

Page 11: Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.

Open “booster valve” to gain more regulated pressure

Page 12: Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.

Open “fill valve”

Page 13: Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.

Allow bottle to be filled until booster has stopped creating

pressure

Page 14: Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.

Shut down procedures• Close fill valve

• Close booster valve

• Decrease regulator pressure down to 0 psi

• Close supply valve

• Open fill station door

• Close bottle

• Close fill valve

• Open bleeder

• Replace fill valve into storage slot

• Remove bottle

• Close fill station door

Page 15: Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.

Filling more than one bottle

• To fill more than one bottle more efficiently, you may skip shut down procedures and just open fill station door. This will automatically inhibit unit to function until another bottle is connected and fill station door is securely closed.