Blue Gold Which commodity, if you owned it all, would allow you to rule the world…?
Water is a finite resource. There are NO substitutes..!!!
1) 69.3 gallons per day per US resident
2) Only 2% of all water is freshwater
3) All the lakes around Mexico City have dried and it is now sinking into the cavernous remains of its reservoirs 4) California runs out of water in 20 years
5) New Mexico runs out of water in 10 years
6) Ga tried to expand it’s border into Tn to secure water
TopWater Consumers
Thermoelectric Power by far the largest
Irrigation for crop production is next
The supply of potable water to the public is third
Cooling Tower water use typically accounts for 10 to 45% of a facility’s total potable water consumption.
In Florida it can be as much as 75% of total water consumption in a commercial building
A typical 350,000 SF building can consume 8 million gallons of water annually
Of that, 6 million gallons consumed by HVAC and up to 50% of that is wasted via bleed off.
Public Supply %11
Up to 50% HVAC water use is dumped down your building’s drain every year.
Thousands of dollars are going with it.
Cooling Tower Bleed Off
Proper Water Treatment
◦Protects equipment◦Extends equipment life◦Minimizes water and energy costs
Results of Improper Water Treatment
.
ZeroTek CG Solution’s Zero Bleed Tower Treatment Program
A “Green” Water Treatment
Management Program
What is
ZeroTek?
Water softenerMulti-media water filter
Patented Green Chemistry
With our patented chemistry, ZeroTek allows you to TURN OFF the bleed line and SAVE the water going down your drain.
Amazing amount of SAVINGS in water, energy and $$$.
No Scale formation. Any scale present is Dissolved away.
Returns system to Manufacturer’s Original Specifications as a result of scale removal.
Huge energy savings on scaled systems.
Corrosion rates are as good or BETTER than what you are currently experiencing.
System is totally AUTOMATED, for low or no labor hours.
Adds Points For USGBC LEED Building Certification.
From Traditional To SofTek
EfficiencyEfficiency28
24
20
16
12
8
4
0.02 .04 .18.08 .10 .16.12 .14.06
Scale Thickness - Inches
% Increasein Power
Cost
Increase in Power Costs
Based on 100 ton unitOperating 10 hours per day25 days per month
COST OF SCALE COST OF SCALE
2007 water cost is $1.25.
2007 campus is operating on 1200 tons.
2010 water cost is $1.54.
2010 campus is operating on 2250 tons.
Less water is being consumed in June 2010 than June 2007.
Dollar Savings of $5,500 June 2010 over June 2007.
Water Cost Savings Profile
Water Cost Savings Profile
2,250 Tons of Cooling operating at 40% per year = 900 Tons
24 hours per day
7 days per week
From 3.5 cycles of concentration to 21 cycles of concentration
120 ppm of Total Hardness to 0 ppm
2.2 million gallons of water saved from the bleed line drain
Amount of Evaporated Water remains the same
370,000 gallons for processing ZeroTek equipment
2 points for USGBC LEED certification
$12 salt cost per day
Water Cost Savings Profile
Water reduction savings $12,500
Sewage Rebate savings
$30,500
Annual water savings $43,000
Estimated one-time equipment cost $22,000
Return on investment is less than 7 months.
Water Cost Savings Profile
ZeroTekLiquid Assets
Blue Trak 1Accurate automatic Chemical Controller
Works with or without your current chemical controller
Works in conjunction with ZeroTek Blue Trace
Utilizes Spectrometer technology to maintain accurate control settings
Models available for internet and BAS networks
Candidate for USGBC LEED Innovation, 1 point for building certification
SS-BromOSHA Classified as Non Hazardous Biocide
Electrolytic Bromine
Produces oxidizing biocide
Single Drum Treatment Program
No toxic fumes
No spill hazards
Effective against Algae and Legionnella
Candidate for USGBC LEED Innovation, 1 point for building certification Drumless Biocide
Product Cost
20 % polyquat $0.67
98 % hydantoin $ 0.86
20 % DBNPA $ 1.02
25 % trisnitro $ 1.98
10 % MBT $ 1.29
15 % glut $ 4.67
16 % quat $0.94
30 % carbamate $ 0.97
50 % polyquat $ 2.22
1.5 % iso $ 3.45
Stabilized bromine BLB-110 $ 0.62
Biological Fouling
To Determine Biocide dosage Amounts
Generic Product Use Costs
Standard 15 gallons/tonCooling TowerSystem
Evaporative 2 gallons/tonCondenserSystem
Calculated as $ to treat 1000 gallons of cooling water, based on typical product strength, recommended average dosages, and prices as supplied by ProChemTech
Electrolytic Bromine $ 0.28
Valencia Community CollegeWest Campus
Electrolytic Bromine $ 0.28
ZeroTek Equipment
ZeroTek Equipment
ZeroTek Equipment
ZeroTekLiquid Assets
Water Softener to remove the total hardness from the make up to the cooling tower to prevent and remove scale deposition
Multi-media filter to pasteurize the recirculating condenser water
BlueTrak controller to automatically maintain proper inhibitor levels to prevent system corrosion
Mini-Brom non-hazardous biocide to prevent biological fouling
Formed by a group of highly dedicated, experienced, water treatment professionals in 1986, CG Solutions/ProChemTech has emerged as the world leader in zero blowdown technology.
We furnish a complete single source, patent pending, technology package including water softeners, bypass filters, electrolytic bromine filters, biocide, and special water treatment chemistry required to operate a cooling system.
CG Solutions manufactures its product line using state of the art technologies, superior consultants and a dedication to quality, providing complete laboratory analysis and expert technical assistance .
Dedicated to delivering superior products and quality equipment, while adhering to the highest ethical standards.
“Performance, Not Promises”
Thank you for Your Interest in ZeroTek